1
|
Blohm A, Domes C, Merian A, Wolf S, Popp J, Frosch T. Comprehensive multi-gas study by means of fiber-enhanced Raman spectroscopy for the investigation of nitrogen cycle processes. Analyst 2024; 149:1885-1894. [PMID: 38357795 DOI: 10.1039/d4an00023d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2024]
Abstract
The extensive use of synthetic fertilizers has led to a considerable increase in reactive nitrogen input into agricultural and natural systems, resulting in negative effects in multiple ecosystems, the so-called nitrogen cascade. Since the global population relies on fertilization for food production, synthetic fertilizer use needs to be optimized by balancing crop yield and reactive nitrogen losses. Fiber-enhanced Raman spectroscopy (FERS) is introduced as a unique method for the simultaneous quantification of multiple gases to the study processes related to the nitrogen cycle. By monitoring changes in the headspace gas concentrations, processes such as denitrification, nitrification, respiration, and nitrogen fixation, as well as fertilizer addition were studied. The differences in concentration between the ambient and prepared process samples were evident in the Raman spectra, allowing for differentiation of process-specific spectra. Gas mixture concentrations were quantified within a range of low ppm to 100% for the gases N2, O2, CO2, N2O, and NH3. Compositional changes were attributed to processes of the nitrogen cycle. With help of multivariate curve resolution, it was possible to quantify N2O and CO2 simultaneously. The impact of fertilizers on N-cycle processes in soil was simulated and analyzed for identifying active processes. Thus, FERS was proven to be a suitable technique to optimize fertilizer composition and to quantify N2O and NH3 emissions, all with a single device and without further sample preparation.
Collapse
Affiliation(s)
- Annika Blohm
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Christian Domes
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Andreas Merian
- Biophotonics and Biomedical Engineering Group, Technical University Darmstadt, Merckstraße 25, 64283 Darmstadt, Germany.
| | - Sebastian Wolf
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Jürgen Popp
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
- Abbe Centre of Photonics, Friedrich Schiller University, 07743 Jena, Germany
| | - Torsten Frosch
- Biophotonics and Biomedical Engineering Group, Technical University Darmstadt, Merckstraße 25, 64283 Darmstadt, Germany.
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
- Abbe Centre of Photonics, Friedrich Schiller University, 07743 Jena, Germany
| |
Collapse
|
2
|
Blohm A, Domes C, Frosch T. Isotopomeric Peak Assignment for N 2O in Cross-Labeling Experiments by Fiber-Enhanced Raman Multigas Spectroscopy. Anal Chem 2024. [PMID: 38315571 PMCID: PMC10882577 DOI: 10.1021/acs.analchem.3c04236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2024]
Abstract
Human intervention in nature, especially fertilization, greatly increased the amount of N2O emission. While nitrogen fertilizer is used to improve nitrogen availability and thus plant growth, one negative side effect is the increased emission of N2O. Successful regulation and optimization strategies require detailed knowledge of the processes producing N2O in soil. Nitrification and denitrification, the main processes responsible for N2O emissions, can be differentiated using isotopic analysis of N2O. The interplay between these processes is complex, and studies to unravel the different contributions require isotopic cross-labeling and analytical techniques that enable tracking of the labeled compounds. Fiber-enhanced Raman spectroscopy (FERS) was exploited for sensitive quantification of N2O isotopomers alongside N2, O2, and CO2 in multigas compositions and in cross-labeling experiments. FERS enabled the selective and sensitive detection of specific molecular vibrations that could be assigned to various isotopomer peaks. The isotopomers 14N15N16O (2177 cm-1) and 15N14N16O (2202 cm-1) could be clearly distinguished, allowing site-specific measurements. Also, isotopomers containing different oxygen isotopes, such as 14N14N17O, 14N14N18O, 15N15N16O, and 15N14N18O could be identified. A cross-labeling showed the capability of FERS to disentangle the contributions of nitrification and denitrification to the total N2O fluxes while quantifying the total sample headspace composition. Overall, the presented results indicate the potential of FERS for isotopic studies of N2O, which could provide a deeper understanding of the different pathways of the nitrogen cycle.
Collapse
Affiliation(s)
- Annika Blohm
- Leibniz Institute of Photonic Technology, Albert Einstein Str. 9, 07745 Jena, Germany
| | - Christian Domes
- Leibniz Institute of Photonic Technology, Albert Einstein Str. 9, 07745 Jena, Germany
| | - Torsten Frosch
- Biophotonics and Biomedical Engineering Group, Technical University Darmstadt, Merckstr. 25, 64283 Darmstadt, Germany
- Leibniz Institute of Photonic Technology, Albert Einstein Str. 9, 07745 Jena, Germany
| |
Collapse
|
3
|
de Melo L, Cruz IA, Fuess LT, Maynard Santana CE, Bharagava RN, Mulla SI, Bilal M, Saratale GD, Figueiredo RT, Romanholo Ferreira LF. Development of a simple biogas analyzer module (BAM) for real-time biogas production monitoring. ENVIRONMENTAL TECHNOLOGY 2023:1-20. [PMID: 37440597 DOI: 10.1080/09593330.2023.2235457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/15/2023]
Abstract
AbstractAnaerobic digestion (AD) relies on the cooperation of specific microbial communities, making it susceptible to process disruptions that could impact biogas production. In this regard, this study presents a technological solution based on the Arduino platform, in the form of a simple online monitoring system that can track the produced biogas profile, named as biogas analyzer module (BAM). The applicability of the BAM focused on monitoring the biogas produced from sugarcane vinasse inoculated with sewage sludge biodigestion processed in mesophilic conditions (38 oC), in a pH range of 6.5-7.5, and following a three-stage operational model: (i) an adaptation (168 h), (ii) complete mixing (168 h), and (iii) bio-stimulation with glycerol (192 h). Then, the lab-made BAM was used to trace the produced biogas profile, which registered a total biogas volume of 8,719.86 cm3 and biomethane concentration of 95.79% (vol.), removing 90.8% (vol) of carbon dioxide (CO2) and 65.2% (vol) of hydrogen sulfide (H2S). In conclusion, the results ensured good accuracy and efficiency to the device created by comparisons with established standards (chromatographic and colorimetric methods), as well as the cost reduction. The developed device would likely be six times cheaper than what is available in the market.
Collapse
Affiliation(s)
- Luciano de Melo
- Federal Institute of Sergipe, Rod. João Café Filho, 264, 49200-000, Estância, SE, Brazil
| | - Ianny Andrade Cruz
- Graduate Program in Process Engineering, Tiradentes University, Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, SE, Brazil
| | - Lucas Tadeu Fuess
- Biological Processes Laboratory, São Carlos School of Engineering, University of São Paulo, Av. João Dagnone 1100, Santa Angelina, 13563-120, São Carlos, SP, Brazil
| | - Carlos Eduardo Maynard Santana
- Graduate Program in Process Engineering, Tiradentes University, Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, SE, Brazil
| | - Ram Naresh Bharagava
- Laboratory for Bioremediation and Metagenomics Research (LBMR), Department of Microbiology (DM), Babasaheb Bhimrao Ambedkar University (A Central University), Vidya Vihar, Raebareli Road, Lucknow, 226 025, Uttar Pradesh, India
| | - Sikandar I Mulla
- Department of Biochemistry, School of Allied Health Sciences, REVA University, Bangalore, Karnataka, 560064, India
| | - Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huaian 223003, China
| | - Ganesh Dattatraya Saratale
- Department of Food Science and Biotechnology, Dongguk University-Seoul, Ilsandong-gu, Goyang-si, Gyeonggido 10326, Republic of Korea
| | | | - Luiz Fernando Romanholo Ferreira
- Graduate Program in Process Engineering, Tiradentes University, Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, SE, Brazil
- Institute of Technology and Research. Av. Murilo Dantas, 300, Farolândia, 49032-490, Aracaju, SE, Brazil
| |
Collapse
|
4
|
Tanichev AS, Petrov DV. Pressure broadening in Raman spectra of CH 4-N 2, CH 4-CO 2, and CH 4-C 2H 6 gas mixtures. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 291:122396. [PMID: 36696859 DOI: 10.1016/j.saa.2023.122396] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 01/13/2023] [Accepted: 01/17/2023] [Indexed: 06/17/2023]
Abstract
Different molecular environments change the spectrum of a given gas sample involved in a mixture compared to the spectrum of a pure gas. It is necessary to account for this effect to improve the accuracy of the analysis of the natural gas composition by Raman spectroscopy. First, the change in the main components of natural gas (methane, nitrogen, carbon dioxide, and ethane) must be considered. This work is devoted to the mutual influence of CH4-N2, CH4-CO2, and CH4-C2H6 on their characteristic Raman bands in the range of 300-2500 cm-1. The half-width and asymmetry of the Q branches of N2, CO2, and C2H6 as a function of methane concentration were obtained in the range of 1-50 bar. The averaged broadening coefficients of the rotational-vibrational lines of the ν2 band of CH4 perturbed by N2, CO2, and C2H6 are measured. A high-sensitivity spectrometer with a resolution of 0.5 cm-1 based on spontaneous Raman scattering was used to obtain reliable results. The algorithm and all the necessary parameters for simulating the effect of various molecular environments on the Raman bands of the main components of natural gas are presented.
Collapse
Affiliation(s)
- Aleksandr S Tanichev
- Laboratory of Ecological Instrumentation, Institute of Monitoring of Climatic and Ecological Systems, 634055 Tomsk, Russia.
| | - Dmitry V Petrov
- Laboratory of Ecological Instrumentation, Institute of Monitoring of Climatic and Ecological Systems, 634055 Tomsk, Russia; Department of Optics and Spectroscopy, Tomsk State University, 634050 Tomsk, Russia
| |
Collapse
|
5
|
Yang QY, Tan Y, Qu ZH, Sun Y, Liu AW, Hu SM. Multiple Gas Detection by Cavity-Enhanced Raman Spectroscopy with Sub-ppm Sensitivity. Anal Chem 2023; 95:5652-5660. [PMID: 36940417 DOI: 10.1021/acs.analchem.2c05432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/22/2023]
Abstract
Accurate and sensitive detection of multicomponent trace gases below the parts-per-million (ppm) level is needed in a variety of medical, industrial, and environmental applications. Raman spectroscopy can identify multiple molecules in the sample simultaneously and has excellent potential for fast diagnosis of various samples, but applications are often limited by its sensitivity. In this contribution, we report the development of a cavity-enhanced Raman spectroscopy instrument using a narrow-line width 532 nm laser locked with a high-finesse cavity through a Pound-Drever-Hall locking servo, which allows continuous measurement in a broad spectral range. An intracavity laser power of up to 1 kW was achieved with an incident laser power of about 240 mW, resulting in a significant enhancement of the Raman signal in the range of 200-5000 cm-1 and a sub-ppm sensitivity for various molecules. The technique is applied in the detection of different samples, including ambient air, natural gas, and reference gas of sulfur hexafluoride, demonstrating its capability for the quantitative measurement of various trace components.
Collapse
Affiliation(s)
- Qing-Ying Yang
- Department of Chemical Physics, University of Science and Technology of China, Hefei 230026, China
| | - Yan Tan
- Department of Chemical Physics, University of Science and Technology of China, Hefei 230026, China
| | - Zi-Han Qu
- State Grid Hubei Electric Power Research Institute, Wuhan 430071, China
| | - Yu Sun
- Institute of Advanced Science Facilities, Shenzhen 518107, China
| | - An-Wen Liu
- Department of Chemical Physics, University of Science and Technology of China, Hefei 230026, China
| | - Shui-Ming Hu
- Department of Chemical Physics, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
6
|
Biochemical monitoring throughout all stages of rabies virus-like particles production by Raman spectroscopy using global models. J Biotechnol 2023; 363:19-31. [PMID: 36587847 DOI: 10.1016/j.jbiotec.2022.12.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 12/27/2022] [Indexed: 12/30/2022]
Abstract
This work aimed to quantify growth and biochemical parameters (viable cell density, Xv; cell viability, CV; glucose, lactate, glutamine, glutamate, ammonium, and potassium concentrations) in upstream stages to obtain rabies virus-like particles (rabies VLP) from insect cell-baculovirus system using on-line and off-line Raman spectra to calibrate global models with minimal experimental data. Five cultivations in bioreactor were performed. The first one comprised the growth of uninfected Spodoptera frugiperda (Sf9) cells, the second and third runs to obtain recombinant baculovirus (rBV) bearing Rabies G glycoprotein and matrix protein, respectively. The fourth one involved the generation of rabies VLP from rBVs and the last one was a repetition of the third one with cell inoculum infected by rBV. The spectra were acquired through a Raman spectrometer with a 785-nm laser source. The fitted Partial Least Square models for nutrients and metabolites were comparable with those previously reported for mammalian cell lines (Relative error < 15 %). However, the use of this chemometrics approach for Xv and CV was not as accurate as it was for other parameters. The findings from this work established the basis for bioprocess Raman spectroscopical monitoring using insect cells for VLP manufacturing, which are gaining ground in the pharmaceutical industry.
Collapse
|
7
|
Li F, Zhao Q, Sun C, Zhu L, Xia J, Huang B. Probing natural gas components with Raman integrating sphere technology. OPTICS LETTERS 2023; 48:187-190. [PMID: 36638414 DOI: 10.1364/ol.474494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 12/05/2022] [Indexed: 06/17/2023]
Abstract
Raman spectroscopy is a powerful method of probing natural gas components, but higher sensitivity, greater miniaturization, and lower cost techniques are required. Therefore, we designed a Raman integrating sphere-enhanced spectroscopy technology in a volume of 40 × 40 × 20 cm3 based on the principle of integrating sphere reflection. This technology consists of two parts: the first is an integrating sphere model to collect scattered signals, and the second is a right-angle light-boosting system to increase the optical path of the pump light in the sample. Raman integrating sphere technology has a detection limit of 0.5 ppm in the air with an exposure time of 600 s under room temperature and ambient pressure conditions. Experiments of natural gas detection display that the detection limits of ethane, propane, n-butane, isobutane, n-pentane, and isopentane are 28, 28, 95, 28, 189, and 95 ppm, respectively. In addition, there is a linear relationship between the relative Raman intensity and the concentration of each component in natural gas, which can be used as a probe for detecting unknown natural gas components in gas wells.
Collapse
|
8
|
Wolf S, Domes R, Merian A, Domes C, Frosch T. Parallelized Raman Difference Spectroscopy for the Investigation of Chemical Interactions. Anal Chem 2022; 94:10346-10354. [PMID: 35820661 DOI: 10.1021/acs.analchem.2c00222] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Raman spectroscopy provides an extremely high chemical selectivity. Raman difference spectroscopy is a technique to reveal even the smallest differences that occur due to weak interactions between substances and changes in the molecular structure. To enable parallelized and highly sensitive Raman difference spectroscopy in a microtiter-array, a diffractive optical element, a lens array, and a fiber bundle were integrated into a Raman spectroscopy setup in a unique fashion. The setup was evaluated with a microtiter-array containing pyridine-water complexes, and subwavenumber changes below the spectrometer's resolution could be resolved. The spectral changes were emphasized with two-dimensional correlation analysis. Density functional theory calculation and "atoms in molecule" analysis were performed to simulate the intermolecular long-range interactions between water and pyridine molecules and to get insight into the involved noncovalent interactions, respectively. It was found that by the addition of pyridine, the energy portion of hydrogen bonds to the total complexation energy between pyridine and water reduces. These results demonstrate the unique abilities of the new setup to investigate subtle changes due to biochemically important molecular interactions and opens new avenues to perform drug binding assays and to monitor highly parallelized chemical reactions.
Collapse
Affiliation(s)
- Sebastian Wolf
- Leibniz Institute of Photonic Technology, Jena 07745, Germany
| | - Robert Domes
- Leibniz Institute of Photonic Technology, Jena 07745, Germany
| | - Andreas Merian
- Leibniz Institute of Photonic Technology, Jena 07745, Germany
| | - Christian Domes
- Leibniz Institute of Photonic Technology, Jena 07745, Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology, Jena 07745, Germany.,Abbe Center of Photonics, Friedrich Schiller University, Jena 07745, Germany.,Biophotonics and Biomedical Engineering Group, Technical University Darmstadt, Merckstraße 25, 64283 Darmstadt, Germany
| |
Collapse
|
9
|
Milenko K, Yerolatsitis S, Aksnes A, Hjelme DR, Stone JM. Micro-Lensed Negative-Curvature Fibre Probe for Raman Spectroscopy. SENSORS 2021; 21:s21248434. [PMID: 34960527 PMCID: PMC8708690 DOI: 10.3390/s21248434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 12/10/2021] [Accepted: 12/12/2021] [Indexed: 11/16/2022]
Abstract
We developed a novel miniature micro-lensed fibre probe for Raman spectroscopy. The fibre probe consists of a single negative-curvature fibre (NCF) and a spliced, cleaved, micro-lensed fibre cap. Using a single NCF, we minimized the Raman background generated from the silica and maintained the diameter of the probe at less than 0.5 mm. In addition, the cap provided fibre closure by blocking the sample from entering the hollow parts of the fibre, enabling the use of the probe in in vivo applications. Moreover, the micro-lensed cap offered an improved collection efficiency (1.5-times increase) compared to a cleaved end-cap. The sensing capabilities of the micro-lensed probe were demonstrated by measuring different concentrations of glucose in aqueous solutions.
Collapse
Affiliation(s)
- Karolina Milenko
- Department of Electronic Systems, Norwegian University of Science and Technology, O.S. Bragstads Plass 2b, 7034 Trondheim, Norway; (A.A.); (D.R.H.)
- SINTEF Microsystems and Nanotechnology, Gaustadalleen 23C, 0737 Oslo, Norway
- Correspondence:
| | | | - Astrid Aksnes
- Department of Electronic Systems, Norwegian University of Science and Technology, O.S. Bragstads Plass 2b, 7034 Trondheim, Norway; (A.A.); (D.R.H.)
| | - Dag Roar Hjelme
- Department of Electronic Systems, Norwegian University of Science and Technology, O.S. Bragstads Plass 2b, 7034 Trondheim, Norway; (A.A.); (D.R.H.)
| | - James M. Stone
- Department of Physics, University of Bath, Bath BA2 7AY, UK; (S.Y.); (J.M.S.)
| |
Collapse
|
10
|
Petrov D. Comment on Hydrogen and C2-C6 Alkane Sensing in Complex Fuel Gas Mixtures with Fiber-Enhanced Raman Spectroscopy. Anal Chem 2021; 93:16282-16284. [PMID: 34784179 DOI: 10.1021/acs.analchem.1c03358] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Dmitry Petrov
- Institute of Monitoring of Climatic and Ecological Systems, Tomsk 634055, Russia
| |
Collapse
|
11
|
Shen C, Wen C, Huang X, Long X. A Versatile Multiple-Pass Raman System for Industrial Trace Gas Detection. SENSORS (BASEL, SWITZERLAND) 2021; 21:7173. [PMID: 34770478 PMCID: PMC8588027 DOI: 10.3390/s21217173] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 10/16/2021] [Accepted: 10/26/2021] [Indexed: 11/23/2022]
Abstract
The fast and in-line multigas detection is critical for a variety of industrial applications. In the present work, we demonstrate the utility of multiple-pass-enhanced Raman spectroscopy as a unique tool for sensitive industrial multigas detection. Instead of using spherical mirrors, D-shaped mirrors are chosen as cavity mirrors in our design, and 26 total passes are achieved in a simple and compact multiple-pass optical system. Due to the large number of passes achieved inside the multiple-pass cavity, experiments with ambient air show that the noise equivalent detection limit (3σ) of 7.6 Pa (N2), 8.4 Pa (O2) and 2.8 Pa (H2O), which correspond to relative abundance by volume at 1 bar total pressure of 76 ppm, 84 ppm and 28 ppm, can be achieved in one second with a 1.5 W red laser. Moreover, this multiple-pass Raman system can be easily upgraded to a multiple-channel detection system, and a two-channel detection system is demonstrated and characterized. High utilization ratio of laser energy (defined as the ratio of laser energy at sampling point to the laser output energy) is realized in this design, and high sensitivity is achieved in every sampling position. Compared with single-point sampling system, the back-to-back experiments show that LODs of 8.0 Pa, 8.9 Pa and 3.0 Pa can be achieved for N2, O2 and H2O in one second. Methods to further improve the system performance are also briefly discussed, and the analysis shows that similar or even better sensitivity can be achieved in both sampling positions for practical industrial applications.
Collapse
Affiliation(s)
| | | | | | - Xinggui Long
- Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, China; (C.S.); (C.W.); (X.H.)
| |
Collapse
|
12
|
Singh J, Muller A. Isotopic trace analysis of water vapor with multipass cavity Raman scattering. Analyst 2021; 146:6482-6489. [PMID: 34581323 DOI: 10.1039/d1an01254a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Cavity-enhanced spontaneous Raman scattering was investigated as a means of simple and inexpensive isotopic water analysis. A multimode blue laser diode equipped with a feedback-generating multipass cavity provided a 100-fold Raman enhancement at a pump linewidth of 3.5 cm-1. Samples containing trace amounts of 1H2H16O were probed at deuterium-hydrogen concentration ratios ranging from 157 parts-per-million (local seawater) down to 8 parts-per-million (deuterium depleted water). All measurements were performed in argon or dried air at atmospheric pressure at 1H2H16O concentrations nearing 100 parts per billion with an uncooled camera at exposure times as short as a few minutes.
Collapse
Affiliation(s)
- Jaspreet Singh
- Department of Physics, University of South Florida, Tampa, Florida, 33620, USA.
| | - Andreas Muller
- Department of Physics, University of South Florida, Tampa, Florida, 33620, USA.
| |
Collapse
|
13
|
Wang J, Chen W, Wang P, Zhang Z, Wan F, Zhou F, Song R, Wang Y, Gao S. Fiber-enhanced Raman spectroscopy for highly sensitive H 2 and SO 2 sensing with a hollow-core anti-resonant fiber. OPTICS EXPRESS 2021; 29:32296-32311. [PMID: 34615304 DOI: 10.1364/oe.437693] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 09/13/2021] [Indexed: 06/13/2023]
Abstract
An innovative fiber-enhanced Raman gas sensing system with a hollow-core anti-resonant fiber is introduced. Two iris diaphragms are implemented for spatial filtering, and a reflecting mirror is attached to one fiber end that provides a highly improved Raman signal enhancement over 2.9 times than the typical bare fiber system. The analytical performance for multigas compositions is thoroughly demonstrated by recording the Raman spectra of carbon dioxide (CO2), oxygen (O2), nitrogen (N2), hydrogen (H2), and sulfur dioxide (SO2) with limits of detection down to low-ppm levels as well as a long-term instability < 1.05%. The excellent linear relationship between Raman signal intensity (peak height) and gas concentrations indicates a promising potential for accurate quantification.
Collapse
|
14
|
Knebl A, Domes C, Domes R, Wolf S, Popp J, Frosch T. Hydrogen and C2-C6 Alkane Sensing in Complex Fuel Gas Mixtures with Fiber-Enhanced Raman Spectroscopy. Anal Chem 2021; 93:10546-10552. [PMID: 34297525 DOI: 10.1021/acs.analchem.1c01500] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Power-to-gas is a heavily discussed option to store surplus electricity from renewable sources. Part of the generated hydrogen could be fed into the gas grid and lead to fluctuations in the composition of the fuel gas. Consequently, both operators of transmission networks and end users would need to frequently monitor the gas to ensure safety as well as optimal and stable operation. Currently, gas chromatography-based analysis methods are the state of the art. However, these methods have several downsides for time-resolved and distributed application and Raman gas spectroscopy is favorable for future point-of-use monitoring. Here, we demonstrate that fiber-enhanced Raman gas spectroscopy (FERS) enables the simultaneous detection of all relevant gases, from major (methane, CH4; hydrogen, H2) to minor (C2-C6 alkanes) fuel gas components. The characteristic peaks of H2 (585 cm-1), CH4 (2917 cm-1), isopentane (765 cm-1), i-butane (798 cm-1), n-butane (830 cm-1), n-pentane (840 cm-1), propane (869 cm-1), ethane (993 cm-1), and n-hexane (1038 cm-1) are well resolved in the broadband spectra acquired with a compact spectrometer. The fiber enhancement achieved in a hollow-core antiresonant fiber enables highly sensitive measurements with limits of detection between 90 and 180 ppm for different hydrocarbons. Both methane and hydrogen were quantified with high accuracy with average relative errors of 1.1% for CH4 and 1.5% for H2 over a wide concentration range. These results show that FERS is ideally suited for comprehensive fuel gas analysis in a future, where regenerative sources lead to fluctuations in the composition of gas.
Collapse
Affiliation(s)
- Andreas Knebl
- Leibniz Institute of Photonic Technology Jena, Albert Einstein Strasse 9, Jena 07745, Germany
| | - Christian Domes
- Leibniz Institute of Photonic Technology Jena, Albert Einstein Strasse 9, Jena 07745, Germany
| | - Robert Domes
- Leibniz Institute of Photonic Technology Jena, Albert Einstein Strasse 9, Jena 07745, Germany
| | - Sebastian Wolf
- Leibniz Institute of Photonic Technology Jena, Albert Einstein Strasse 9, Jena 07745, Germany
| | - Juergen Popp
- Leibniz Institute of Photonic Technology Jena, Albert Einstein Strasse 9, Jena 07745, Germany.,Institute of Physical Chemistry & Abbe Center of Photonics, Friedrich Schiller University, Jena 07745, Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology Jena, Albert Einstein Strasse 9, Jena 07745, Germany.,Institute of Physical Chemistry & Abbe Center of Photonics, Friedrich Schiller University, Jena 07745, Germany.,Biophotonics and Biomedical Engineering Group, Technical University Darmstadt, Merckstraße 25, Darmstadt 64283, Germany
| |
Collapse
|
15
|
Tuesta AD, Fisher BT, Skiba AW, Williams LT, Osborn MF. Low-pressure multipass Raman spectrometer. APPLIED OPTICS 2021; 60:773-784. [PMID: 33690456 DOI: 10.1364/ao.412054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 12/16/2020] [Indexed: 06/12/2023]
Abstract
Nonintrusive, quantitative measurements of thermodynamic properties of flows associated with propulsion systems are pivotal to advance their design and optimization. Laser-based diagnostics are ideal to provide quantitative results without influencing the flow; however, the environments in which such flows exist are often not conducive for such techniques. Namely, they often lack the optical accessibility required to facilitate the delivery of incident laser radiation and the subsequent collection of induced signals. A particularly challenging, yet crucial, task is to measure thermodynamic properties of plumes issuing from thrusters operating within a vacuum chamber. Large chambers used to simulate the vacuum of space generally lack optical ports that can facilitate complex laser-based measurements. Additionally, the near-vacuum environments within such chambers coupled with the ability of thrusters to efficiently expand the gas flowing through their nozzles lead to plumes with prohibitively low number densities (pressures below 1 Torr). Thus, there is a need to develop a diagnostic system that can offer high throughput without the use of free-space optical ports. Moreover, facilities where propulsion systems are tested typically lack vibrationally isolated space for diagnostic equipment and accurate climate control. As a result, such a high-throughput system must also be compact, versatile, and robust. To this end, the present work describes a fiber-coupled, multipass cell, spontaneous Raman scattering spectroscopy system. This system is intended to provide accurate temperature measurements within low-pressure environments via H2 rotational Raman thermometry. Proof-of-principle measurements are successfully performed at pressures as low as 67 Pa (500 mTorr). Techniques to maintain the signal-to-noise ratio at lower pressures, and the trade-offs associated with them, are discussed and evaluated. Finally, the ability of this system to facilitate additional quantitative measurements is also discussed.
Collapse
|
16
|
Maity A, Maithani S, Pradhan M. Cavity Ring-Down Spectroscopy: Recent Technological Advancements, Techniques, and Applications. Anal Chem 2020; 93:388-416. [DOI: 10.1021/acs.analchem.0c04329] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Abhijit Maity
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
- Technical Research Centre, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
| | - Sanchi Maithani
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
| | - Manik Pradhan
- Department of Chemical, Biological and Macromolecular Sciences, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
- Technical Research Centre, S. N. Bose National Centre for Basic Sciences, Salt Lake, JD Block, Sector III, Kolkata 700106, India
| |
Collapse
|
17
|
Knebl A, Domes R, Wolf S, Domes C, Popp J, Frosch T. Fiber-Enhanced Raman Gas Spectroscopy for the Study of Microbial Methanogenesis. Anal Chem 2020; 92:12564-12571. [PMID: 32845132 DOI: 10.1021/acs.analchem.0c02507] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Microbial methanogenesis is a key biogeochemical process in the carbon cycle that is responsible for 70% of global emissions of the potent greenhouse gas methane (CH4). Further knowledge about microbial methanogenesis is crucial to mitigate emissions, increase climate model accuracy, or advance methanogenic biogas production. The current understanding of the substrate use of methanogenic microbes is limited, especially regarding the methylotrophic pathway. Here, we present fiber-enhanced Raman spectroscopy (FERS) of headspace gases as an alternate tool to study methanogenesis and substrate use in particular. The optical technique is nondestructive and sensitive to CH4, hydrogen (H2), and carbon dioxide with a large dynamic range from trace levels (demonstrated LoDs: CH4, 3 ppm; H2, 49 ppm) to pure gases. In addition, the portable FERS system can provide quantitative information about methanol concentration in the liquid phase of microbial cultures through headspace gas sampling (LoD 25 ppm). We demonstrate how FERS gas sensing could enable us to track substrate and product levels of microbial methanogenesis with just one instrument. The versatility of Raman gas spectroscopy could moreover help us to elucidate links between nitrogen and carbon cycle in microbial communities in the near future.
Collapse
Affiliation(s)
- Andreas Knebl
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Robert Domes
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Sebastian Wolf
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Christian Domes
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Juergen Popp
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany.,Friedrich Schiller University, Institute of Physical Chemistry, 07743 Jena, Germany.,Friedrich Schiller University, Abbe Center of Photonics, 07745 Jena, Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany.,Friedrich Schiller University, Institute of Physical Chemistry, 07743 Jena, Germany.,Friedrich Schiller University, Abbe Center of Photonics, 07745 Jena, Germany
| |
Collapse
|
18
|
Petrov DV, Matrosov II, Zaripov AR, Maznoy AS. Application of Raman Spectroscopy for Determination of Syngas Composition. APPLIED SPECTROSCOPY 2020; 74:948-953. [PMID: 32186201 DOI: 10.1177/0003702820917222] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Raman spectroscopy is a unique tool for fast analysis of multicomponent gas media. In this work, we studied the features of application of this method for monitoring the syngas (mixture of CO + H2 + CH4 + CO2 + N2) composition. To determine concentrations, we used contour fit method, where the Raman spectrum of mixture is compared with a synthetically calculated spectrum. The effects of pressure changes and various exposure times on the accuracy of measurements are investigated. It was found that effect of pressure and environment on band contours results in measurement errors several times higher than the errors caused by deviations of the signal intensities.
Collapse
Affiliation(s)
- Dmitry V Petrov
- Tomsk State University, Tomsk, Russia
- Institute of Monitoring of Climatic and Ecological Systems, Tomsk, Russia
| | - Ivan I Matrosov
- Institute of Monitoring of Climatic and Ecological Systems, Tomsk, Russia
| | - Alexey R Zaripov
- Institute of Monitoring of Climatic and Ecological Systems, Tomsk, Russia
| | | |
Collapse
|
19
|
Cocola L, Tondello G, Poletto L. A non-dispersive approach for a Raman gas sensor. SN APPLIED SCIENCES 2020. [DOI: 10.1007/s42452-020-2688-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
20
|
Depolarization Ratios of Methane Raman Bands as a Function of Pressure. MOLECULES (BASEL, SWITZERLAND) 2020; 25:molecules25081951. [PMID: 32331479 PMCID: PMC7221953 DOI: 10.3390/molecules25081951] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 12/15/2022]
Abstract
In this work, we measured the intensities of Q-branches of the ν1, ν2 and ν3 bands in the polarized and depolarized methane Raman spectra in the pressure range of 1–60 atm. It was established that the pressure dependence of depolarization ratios of the ν2 and ν3 bands are negligible. In turn, the depolarization ratio of the ν1 band increases with increasing pressure and reaches approximately 0.0045 at 60 atm. These data are more precise than previously published ones because ν1 band intensities were determined taking into account the contribution of overlapping lines of ν3 band. The presented data will be useful in calculating the methane polarizabilities at high pressure, as well as in calculating methane Raman spectra for measuring the natural gas composition using Raman spectroscopy.
Collapse
|
21
|
Wang P, Chen W, Wang J, Tang J, Shi Y, Wan F. Multigas Analysis by Cavity-Enhanced Raman Spectroscopy for Power Transformer Diagnosis. Anal Chem 2020; 92:5969-5977. [PMID: 32216282 DOI: 10.1021/acs.analchem.0c00179] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
We demonstrate the utility of cavity-enhanced Raman spectroscopy (CERS) as a unique multigas analysis tool for power transformer diagnosis. For this purpose, improvements have been added to our recently introduced CERS apparatus. Based on optical feedback frequency-locking, laser radiation is coupled into a high-finesse optical cavity, thus resulting in huge intracavity laser power. With 20 s exposure time, ppm-level gas sensing at 1 bar total pressure is achieved, including carbon dioxide (CO2), carbon monoxide (CO), hydrogen (H2), methane (CH4), ethane (C2H6), ethylene (C2H4), acetylene (C2H2), nitrogen (N2), and oxygen (O2). By using the internal standard gas (sulfur hexafluoride, SF6), the quantification of multigas with high accuracy is also realized, which is confirmed by the measurement of calibration gases. For fault diagnosis, transformer oil is sampled from a 110 kV power transformer in service. Dissolved gases are extracted and analyzed by the CERS apparatus. Then the transformer is diagnosed according to the measurement results. CERS has the ability to analyze multigas with high selectivity, sensitivity, and accuracy, it has great potential in gas sensing fields.
Collapse
Affiliation(s)
- Pinyi Wang
- State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, No. 174, Shazheng Street, Chongqing, 400044, China
| | - Weigen Chen
- State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, No. 174, Shazheng Street, Chongqing, 400044, China
| | - Jianxin Wang
- State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, No. 174, Shazheng Street, Chongqing, 400044, China
| | - Jun Tang
- State Grid Sichuan Electric Power Company, No. 18, Jiaozi North Second Road, Chengdu, 610041, China
| | - Yongli Shi
- China Southern Power Grid Company Limited, No. 137, Guanshan West Road, Guiyang, 550081, China
| | - Fu Wan
- State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, No. 174, Shazheng Street, Chongqing, 400044, China
| |
Collapse
|
22
|
Rapid Raman Spectroscopic Analysis of Stress Induced Degradation of the Pharmaceutical Drug Tetracycline. Molecules 2020; 25:molecules25081866. [PMID: 32316681 PMCID: PMC7221697 DOI: 10.3390/molecules25081866] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 04/07/2020] [Accepted: 04/08/2020] [Indexed: 12/14/2022] Open
Abstract
Stress factors caused by inadequate storage can induce the unwanted degradation of active compounds in pharmaceutical formulations. Resonance Raman spectroscopy is presented as an analytical tool for rapid monitoring of small concentration changes of tetracycline and the metabolite 4˗epianhydrotetracycline. These degradation processes were experimentally induced by changes in temperature, humidity, and irradiation with visible light over a time period of up to 23 days. The excitation wavelength λexc = 413 nm was proven to provide short acquisition times for the simultaneous Raman spectroscopic detection of the degradation of tetracycline and production of its impurity in small sample volumes. Small concentration changes could be detected (down to 1.4% for tetracycline and 0.3% for 4-epianhydrotetracycline), which shows the potential of resonance Raman spectroscopy for analyzing the decomposition of pharmaceutical products.
Collapse
|
23
|
Petrov DV, Kostenko MA, Shcherbakov AA. Silver holographic gratings as substrates for surface-enhanced Raman scattering gas analysis. APPLIED OPTICS 2020; 59:2929-2934. [PMID: 32225843 DOI: 10.1364/ao.386897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Accepted: 02/21/2020] [Indexed: 06/10/2023]
Abstract
This work is devoted to the investigation of the enhancement of Raman signals of nonadsorbed gases in the vicinity of corrugated metallic surfaces supporting propagating surface plasmon-polaritons (PSPPs). Simulation of the PSPP excitation efficiency on holographic gratings coated with silver films of various thicknesses at different groove heights was carried out. Verification showed good agreement between theory and experiment. Also, it was found that an increase of the PSPP excitation efficiency may not lead to an increase in the enhancement factor of Raman signals of gases located near the surface-enhanced Raman scattering active surface. For a holographic grating with a period of 667 nm, a groove height of 70 nm, and a silver film thickness of 30 nm coated with a protective ${{\rm Al}_2}{{\rm O}_3}$Al2O3 layer, the enhancement factor of Raman signals of nonadsorbed nitrogen molecules was $\sim{{\rm 4\cdot10}^3}$∼4⋅103.
Collapse
|
24
|
Wolf S, Frosch T, Popp J, Pletz MW, Frosch T. Highly Sensitive Detection of the Antibiotic Ciprofloxacin by Means of Fiber Enhanced Raman Spectroscopy. Molecules 2019; 24:molecules24244512. [PMID: 31835489 PMCID: PMC6943513 DOI: 10.3390/molecules24244512] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 12/05/2019] [Accepted: 12/06/2019] [Indexed: 12/13/2022] Open
Abstract
Sepsis and septic shock exhibit a rapid course and a high fatality rate. Antibiotic treatment is time-critical and precise knowledge of the antibiotic concentration during the patients’ treatment would allow individual dose adaption. Over- and underdosing will increase the antimicrobial efficacy and reduce toxicity. We demonstrated that fiber enhanced Raman spectroscopy (FERS) can be used to detect very low concentrations of ciprofloxacin in clinically relevant doses, down to 1.5 µM. Fiber enhancement was achieved in bandgap shifted photonic crystal fibers. The high linearity between the Raman signals and the drug concentrations allows a robust calibration for drug quantification. The needed sample volume was very low (0.58 µL) and an acquisition time of 30 s allowed the rapid monitoring of ciprofloxacin levels in a less invasive way than conventional techniques. These results demonstrate that FERS has a high potential for clinical in-situ monitoring of ciprofloxacin levels.
Collapse
Affiliation(s)
- Sebastian Wolf
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Timea Frosch
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Juergen Popp
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
- Institute of Physical Chemistry, Friedrich Schiller University, 07743 Jena, Germany
- Abbe Center of Photonics, Friedrich Schiller University, 07745 Jena, Germany
| | - Mathias W. Pletz
- Institute of Infectious Diseases and Infection Control, University Hospital, 07747 Jena, Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
- Institute of Physical Chemistry, Friedrich Schiller University, 07743 Jena, Germany
- Abbe Center of Photonics, Friedrich Schiller University, 07745 Jena, Germany
- Correspondence: or
| |
Collapse
|
25
|
Frosch T, Wyrwich E, Yan D, Popp J, Frosch T. Fiber-Array-Based Raman Hyperspectral Imaging for Simultaneous, Chemically-Selective Monitoring of Particle Size and Shape of Active Ingredients in Analgesic Tablets. Molecules 2019; 24:E4381. [PMID: 31801249 PMCID: PMC6930444 DOI: 10.3390/molecules24234381] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 11/17/2019] [Accepted: 11/28/2019] [Indexed: 11/20/2022] Open
Abstract
The particle shape, size and distribution of active pharmaceutical ingredients (API) are relevant quality indicators of pharmaceutical tablets due to their high impact on the manufacturing process. Furthermore, the bioavailability of the APIs from the dosage form depends largely on these characteristics. Routinely, particle size and shape are only analyzed in the powder form, without regard to the effect of the formulation procedure on the particle characteristics. The monitoring of these parameters improves the understanding of the process; therefore, higher quality and better control over the biopharmaceutical profile can be ensured. A new fiber-array-based Raman hyperspectral imaging technique is presented for direct simultaneous in-situ monitoring of three different active pharmaceutical ingredients- acetylsalicylic acid, acetaminophen and caffeine- in analgesic tablets. This novel method enables a chemically selective, noninvasive assessment of the distribution of the active ingredients down to 1 µm spatial resolution. The occurrence of spherical and needle-like particles, as well as agglomerations and the respective particle size ranges, were rapidly determined for two commercially available analgesic tablet types. Subtle differences were observed in comparison between these two tablets. Higher amounts of acetaminophen were visible, more needle-shaped and bigger acetylsalicylic acid particles, and a higher incidence of bigger agglomerations were found in one of the analgesic tablets.
Collapse
Affiliation(s)
- Timea Frosch
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany; (T.F.); (E.W.); (D.Y.); (J.P.)
| | - Elisabeth Wyrwich
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany; (T.F.); (E.W.); (D.Y.); (J.P.)
| | - Di Yan
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany; (T.F.); (E.W.); (D.Y.); (J.P.)
| | - Juergen Popp
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany; (T.F.); (E.W.); (D.Y.); (J.P.)
- Institute of Physical Chemistry, Friedrich Schiller University, 07743 Jena, Germany
- Abbe Centre of Photonics, Friedrich Schiller University, 07745 code Jena, Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany; (T.F.); (E.W.); (D.Y.); (J.P.)
- Institute of Physical Chemistry, Friedrich Schiller University, 07743 Jena, Germany
- Abbe Centre of Photonics, Friedrich Schiller University, 07745 code Jena, Germany
| |
Collapse
|
26
|
Wang P, Chen W, Wan F, Wang J, Hu J. Cavity-enhanced Raman spectroscopy with optical feedback frequency-locking for gas sensing. OPTICS EXPRESS 2019; 27:33312-33325. [PMID: 31878402 DOI: 10.1364/oe.27.033312] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 10/09/2019] [Indexed: 06/10/2023]
Abstract
A cavity-enhanced Raman spectroscopy (CERS) gas-sensing method is introduced. Using optical feedback frequency-locking, laser radiation provided by a diode laser is coupled into a three-mirror V-shaped optical cavity. An intracavity laser power of 92 W is realized, yielding a power gain factor of 2200. Raman spectrums of air, carbon dioxide, and acetylene are recorded as a demonstration. Multicomponent gas mixtures including isotopic gases can be simultaneously sensed by CERS. With 200 s exposure time, detection limits of 5.35 Pa for N2, 5.07 Pa for O2, 1.74 Pa for CO2, and 0.58 Pa for C2H2 are achieved. CERS is a powerful gas-sensing method with high selectivity and sensitivity, which also has the potential for quantitative analysis of gases with high accuracy.
Collapse
|
27
|
Selvaraj R, Vasa NJ, Shiva Nagendra SM. Off-Resonance Photoacoustic Spectroscopy Technique for Multi-Gas Sensing in Biogas Plants. Anal Chem 2019; 91:14239-14246. [DOI: 10.1021/acs.analchem.9b01513] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Ramya Selvaraj
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai-600036, India
| | - Nilesh J. Vasa
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai-600036, India
| | - S. M. Shiva Nagendra
- Department of Civil Engineering, Indian Institute of Technology Madras, Chennai-600036, India
| |
Collapse
|
28
|
Le VH, Caumon MC, Tarantola A, Randi A, Robert P, Mullis J. Quantitative Measurements of Composition, Pressure, and Density of Microvolumes of CO2–N2 Gas Mixtures by Raman Spectroscopy. Anal Chem 2019; 91:14359-14367. [DOI: 10.1021/acs.analchem.9b02803] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Van-Hoan Le
- Université de Lorraine, CNRS, GeoResssources Laboratory, BP 70239, F-54506 Vandoeuvre-lès-Nancy, France
| | - Marie-Camille Caumon
- Université de Lorraine, CNRS, GeoResssources Laboratory, BP 70239, F-54506 Vandoeuvre-lès-Nancy, France
| | - Alexandre Tarantola
- Université de Lorraine, CNRS, GeoResssources Laboratory, BP 70239, F-54506 Vandoeuvre-lès-Nancy, France
| | - Aurélien Randi
- Université de Lorraine, CNRS, GeoResssources Laboratory, BP 70239, F-54506 Vandoeuvre-lès-Nancy, France
| | - Pascal Robert
- Université de Lorraine, CNRS, GeoResssources Laboratory, BP 70239, F-54506 Vandoeuvre-lès-Nancy, France
| | - Josef Mullis
- Mineralogisch-Petrographisches Institut, Bernoullistrasse 30, CH-4056 Basel, Switzerland
| |
Collapse
|
29
|
Sieburg A, Knebl A, Jacob JM, Frosch T. Characterization of fuel gases with fiber-enhanced Raman spectroscopy. Anal Bioanal Chem 2019; 411:7399-7408. [DOI: 10.1007/s00216-019-02145-x] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 08/19/2019] [Accepted: 09/06/2019] [Indexed: 12/15/2022]
|
30
|
Frosch T, Wyrwich E, Yan D, Domes C, Domes R, Popp J, Frosch T. Counterfeit and Substandard Test of the Antimalarial Tablet Riamet ® by Means of Raman Hyperspectral Multicomponent Analysis. Molecules 2019; 24:molecules24183229. [PMID: 31491881 PMCID: PMC6767462 DOI: 10.3390/molecules24183229] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 08/31/2019] [Accepted: 09/02/2019] [Indexed: 02/06/2023] Open
Abstract
The fight against counterfeit pharmaceuticals is a global issue of utmost importance, as failed medication results in millions of deaths every year. Particularly affected are antimalarial tablets. A very important issue is the identification of substandard tablets that do not contain the nominal amounts of the active pharmaceutical ingredient (API), and the differentiation between genuine products and products without any active ingredient or with a false active ingredient. This work presents a novel approach based on fiber-array based Raman hyperspectral imaging to qualify and quantify the antimalarial APIs lumefantrine and artemether directly and non-invasively in a tablet in a time-efficient way. The investigations were carried out with the antimalarial tablet Riamet® and self-made model tablets, which were used as examples of counterfeits and substandard. Partial least-squares regression modeling and density functional theory calculations were carried out for quantification of lumefantrine and artemether and for spectral band assignment. The most prominent differentiating vibrational signatures of the APIs were presented.
Collapse
Affiliation(s)
- Timea Frosch
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | | | - Di Yan
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Christian Domes
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Robert Domes
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
| | - Juergen Popp
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany
- Friedrich Schiller University, Institute of Physical Chemistry, 07745 Jena, Germany
- Friedrich Schiller University, Abbe Centre of Photonics, 07745 Jena, Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology, 07745 Jena, Germany.
- Friedrich Schiller University, Institute of Physical Chemistry, 07745 Jena, Germany.
- Friedrich Schiller University, Abbe Centre of Photonics, 07745 Jena, Germany.
| |
Collapse
|
31
|
Bierer B, Kress P, Nägele HJ, Lemmer A, Palzer S. Investigating flexible feeding effects on the biogas quality in full-scale anaerobic digestion by high resolution, photoacoustic-based NDIR sensing. Eng Life Sci 2019; 19:700-710. [PMID: 32624963 DOI: 10.1002/elsc.201900046] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 07/30/2019] [Accepted: 08/07/2019] [Indexed: 01/30/2023] Open
Abstract
In future energy systems based on renewable energies, biogas plants can make a significant contribution to stabilizing the electricity grids. However, this requires load-flexible and demand-oriented electricity production by means of flexible feed management. However, these flexible feeding strategies using greatly oscillating, temporally varying high mass loads may lead to critical process failures of the anaerobic digestion process. Currently there is no online, high resolution gas quality measurement technique to detect and prevent biological process failures available. In this contribution, we present a miniaturized, low-cost biogas quality measurement system providing data with high precision and high temporal resolution to overcome this technology gap. To highlight the capabilities of the system we have installed it using a bypass to the main biogas duct after hydrogen sulfide removal at a full-scale research biogas plant. During a three-month field trial, the effect of flexible feeding on the biogas quality has been monitored. The results demonstrate long-term stability of the sensor solution and reveal the effects of changing feeding frequency and composition on gas quantity and quality, which cannot be detected with commercially available state-of-the-art sensing systems.
Collapse
Affiliation(s)
- Benedikt Bierer
- Laboratory for Gas Sensors Department of Microsystems Engineering University of Freiburg Freiburg Germany.,Fraunhofer Institute for Physical Measurement Techniques (IPM) Freiburg Germany
| | - Philipp Kress
- State Institute of Agricultural Engineering and Bioenergy University of Hohenheim Stuttgart Germany
| | - Hans-Joachim Nägele
- State Institute of Agricultural Engineering and Bioenergy University of Hohenheim Stuttgart Germany.,Institut für Chemie & Biotechnologie (ICBT) Zürcher Hochschule für Angewandte Wissenschaften Wädenswil Switzerland
| | - Andreas Lemmer
- State Institute of Agricultural Engineering and Bioenergy University of Hohenheim Stuttgart Germany
| | - Stefan Palzer
- Escuela Politécnica Superior Universidad Autónoma de Madrid Madrid Spain
| |
Collapse
|
32
|
Petrov DV, Matrosov II, Zaripov AR, Maznoy AS. Effects of pressure and composition on Raman spectra of CO-H 2-CO 2-CH 4 mixtures. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 215:363-370. [PMID: 30852284 DOI: 10.1016/j.saa.2019.03.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 02/26/2019] [Accepted: 03/03/2019] [Indexed: 06/09/2023]
Abstract
There is great interest in the development of renewable and environmentally friendly fuel sources such as biogas and syngas for generation of heat and electricity. Raman spectroscopy is a promising method for rapid quantitative analysis of the composition of such gases. To improve the accuracy of the method, information is needed on changes in the spectra of the main components as a function of pressure and gas composition. In this work the spectral characteristics of the most intense peaks of methane, carbon monoxide, carbon dioxide and hydrogen in the range of 200-3800 cm-1 were investigated in the range of 1-25 bar for pure gases and binary mixtures. It has been revealed that, under these conditions, the change in the characteristics of pure rotational hydrogen lines is negligible, while the Q-branches of the main vibrational bands of methane, carbon monoxide and carbon dioxide shift to a few tenths of cm-1. The values of errors that can occur in the case of ignoring such changes in the spectra are estimated.
Collapse
Affiliation(s)
- D V Petrov
- Institute of Monitoring of Climatic and Ecological Systems, 10/3 Academicheskiy ave., 634055 Tomsk, Russia; Tomsk State University, 36 Lenina ave., 634050 Tomsk, Russia.
| | - I I Matrosov
- Institute of Monitoring of Climatic and Ecological Systems, 10/3 Academicheskiy ave., 634055 Tomsk, Russia
| | - A R Zaripov
- Institute of Monitoring of Climatic and Ecological Systems, 10/3 Academicheskiy ave., 634055 Tomsk, Russia
| | - A S Maznoy
- Tomsk Scientific Center, 10/4 Academicheskiy ave., 634055 Tomsk, Russia
| |
Collapse
|
33
|
Knebl A, Domes R, Yan D, Popp J, Trumbore S, Frosch T. Fiber-Enhanced Raman Gas Spectroscopy for 18O- 13C-Labeling Experiments. Anal Chem 2019; 91:7562-7569. [PMID: 31050402 DOI: 10.1021/acs.analchem.8b05684] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Stable isotopes are used in ecology to track and disentangle different processes and pathways. Especially for studies focused on the gas exchange of plants, sensing techniques that offer oxygen (O2) and carbon dioxide (CO2) sensitivity with isotopic discrimination are highly sought after. Addressing this challenge, fiber-enhanced Raman gas spectroscopy is introduced as a fast optical technique directly combining 13CO2 and 12CO2 as well as 18O2 and 16O2 measurements in one instrument. We demonstrate how a new type of optical hollow-core fiber, the so-called revolver fiber, is utilized for enhanced Raman gas sensing. Carbon dioxide and oxygen isotopologues were measured at concentrations expected when using 13C- and 18O-labeled gases in plant experiments. Limits of detection have been determined to be 25 ppm for CO2 and 150 ppm for O2. The combination of measurements with different integration times allows the creation of highly resolved broadband spectra. With the help of calculations based on density functional theory, the line at 1512 cm-1 occurring in the oxygen spectrum is assigned to 18O16O. The relative abundances of the isotopologues 18O16O and nitrogen 15N14N were in good agreement with typical values. For CO2, fiber-enhanced Raman spectra show the Fermi diad and hotbands of 12C16O2, 13C16O2, and 12C18O16O. Several weak lines were observed, and the line at 1426 cm-1 was identified as originating from the (0 4 0 2) → (0 2 0 2) transition of 12C16O2. With the demonstrated sensitivity and discriminatory power, fiber-enhanced Raman spectroscopy is a possible alternative means to investigate plant metabolism, directly combining 13CO2 and 12CO2 measurements with 18O2 and 16O2 measurements in one instrument. The presented method thus has large potential for basic analytical investigations as well as for applications in the environmental sciences.
Collapse
Affiliation(s)
- Andreas Knebl
- Leibniz Institute of Photonic Technology , 07745 Jena , Germany.,Max-Planck-Institute for Biogeochemistry , 07745 Jena , Germany
| | - Robert Domes
- Leibniz Institute of Photonic Technology , 07745 Jena , Germany
| | - Di Yan
- Leibniz Institute of Photonic Technology , 07745 Jena , Germany
| | - Juergen Popp
- Leibniz Institute of Photonic Technology , 07745 Jena , Germany.,Institute of Physical Chemistry & Abbe Center of Photonics , Friedrich Schiller University , 07743 Jena , Germany
| | - Susan Trumbore
- Max-Planck-Institute for Biogeochemistry , 07745 Jena , Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology , 07745 Jena , Germany.,Institute of Physical Chemistry & Abbe Center of Photonics , Friedrich Schiller University , 07743 Jena , Germany
| |
Collapse
|
34
|
Yan D, Frosch T, Kobelke J, Bierlich J, Popp J, Pletz MW, Frosch T. Fiber-Enhanced Raman Sensing of Cefuroxime in Human Urine. Anal Chem 2018; 90:13243-13248. [PMID: 30387601 DOI: 10.1021/acs.analchem.8b01355] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Fiber-enhanced Raman spectroscopy was developed for the chemically selective and sensitive quantification of the important antibiotic cefuroxime in human urine. A novel optical sensor fiber was drawn and precisely prepared. In this fiber structure, light is strongly confined in the selectively filled liquid core, and the Raman scattered signal is collected with unprecedented efficiency over an extended interaction length. The filling, emptying, and robustness are highly improved due to the large core size (>30 μm). Broadband step-index guidance allows the free choice of the most suitable excitation wavelength in complex body fluids. The limit of detection of cefuroxime in human urine was improved by 2 orders of magnitude (to μM level). The quantification of cefuroxime was achieved in urine after oral administration. This method has great potential for the point-of-care monitoring of antibiotics concentrations and is an important step forward to enable clinicians to rapidly adjust doses.
Collapse
Affiliation(s)
- Di Yan
- Leibniz Institute of Photonic Technology , Jena 07745 , Germany
| | - Timea Frosch
- Leibniz Institute of Photonic Technology , Jena 07745 , Germany
| | - Jens Kobelke
- Leibniz Institute of Photonic Technology , Jena 07745 , Germany
| | - Jörg Bierlich
- Leibniz Institute of Photonic Technology , Jena 07745 , Germany
| | - Jürgen Popp
- Leibniz Institute of Photonic Technology , Jena 07745 , Germany.,Friedrich Schiller University , Institute of Physical Chemistry , Jena 07743 , Germany.,Friedrich Schiller University , Abbe Centre of Photonics , Jena 07745 , Germany
| | - Mathias W Pletz
- Center for Infectious Diseases and Infection Control , Jena University Hospital , Jena 07740 , Germany
| | - Torsten Frosch
- Leibniz Institute of Photonic Technology , Jena 07745 , Germany.,Friedrich Schiller University , Institute of Physical Chemistry , Jena 07743 , Germany.,Friedrich Schiller University , Abbe Centre of Photonics , Jena 07745 , Germany
| |
Collapse
|