1
|
Chong SW, Shen Y, Palomba S, Vigolo D. Nanofluidic Lab-On-A-Chip Systems for Biosensing in Healthcare. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2407478. [PMID: 39491535 DOI: 10.1002/smll.202407478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2024] [Revised: 10/21/2024] [Indexed: 11/05/2024]
Abstract
Biosensing plays a vital role in healthcare monitoring, disease detection, and treatment planning. In recent years, nanofluidic technology has been increasingly explored to be developed into lab-on-a-chip biosensing systems. Given now the possibility of fabricating geometrically defined nanometric channels that are commensurate with the size of many biomolecules, nanofluidic-based devices are likely to become a key technology for the analysis of various clinical biomarkers, including DNA (deoxyribonucleic acid) and proteins in liquid biopsies. This review summarizes the fundamentals and technological advances of nanofluidics from the purview of single-molecule analysis, detection of low-abundance molecules, and single-cell analysis at the subcellular level. The extreme confinement and dominant surface charge effects in nanochannels provide unique advantages to nanofluidic devices for the manipulation and transport of target biomarkers. When coupled to a microfluidic network to facilitate sample introduction, integrated micro-nanofluidic biosensing devices are proving to be more sensitive and specific in molecular analysis compared to conventional assays in many cases. Based on recent progress in nanofluidics and current clinical trends, the review concludes with a discussion of near-term challenges and future directions for the development of nanofluidic-based biosensing systems toward enabling a new wave of lab-on-a-chip technology for personalized and preventive medicine.
Collapse
Affiliation(s)
- Shin Wei Chong
- School of Biomedical Engineering, The University of Sydney, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Yi Shen
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
- School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Stefano Palomba
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
- School of Physics, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Daniele Vigolo
- School of Biomedical Engineering, The University of Sydney, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
| |
Collapse
|
2
|
Morikawa K, Takeuchi T, Kitamori T. Local nano-electrode fabrication utilizing nanofluidic and nano-electrochemical control. Electrophoresis 2024. [PMID: 38962855 DOI: 10.1002/elps.202300002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 05/23/2024] [Accepted: 06/19/2024] [Indexed: 07/05/2024]
Abstract
Miniaturized systems have attracted much attention with the recent advances in microfluidics and nanofluidics. From the capillary electrophoresis, the development of glass-based microfluidic and nanofluidic technologies has supported advances in microfluidics and nanofluidics. Most microfluidic systems, especially nanofluidic systems, are still simple, such as systems constructed with simple straight nanochannels and bulk-scale electrodes. One of the bottlenecks to the development of more complicated and sophisticated systems is to develop the locally integrated nano-electrodes. However, there are still issues with integrating nano-electrodes into nanofluidic devices because it is difficult to fit the nano-electrode size into a nanofluidic channel at the nanometer level. In this study, we propose a new method for the fabrication of local nano-electrodes in nanofluidic devices with nanofluidic and nano-electrochemistry-based experiments. An electroplating solution was introduced to a nanochannel with control of the flow and the electroplating reaction, by which nano-electrodes were successfully fabricated. In addition, a nanofluidic device was available for nanofluidic experiments with the application of 200 kPa. This method can be applied to any electroplating material such as gold and copper. The local nano-electrode will make a significant contribution to the development of more complicated and sophisticated nanofluidic electrophoresis systems and to local electric detection methods for various nanofluidic devices.
Collapse
Affiliation(s)
- Kyojiro Morikawa
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, Tokyo, Japan
| | - Tomoaki Takeuchi
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, Tokyo, Japan
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, Tokyo, Japan
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
3
|
Fukasawa T, Yoshizaki-Ogawa A, Enomoto A, Sato S, Yoshizaki A. Apremilast Decreased Proinflammatory Cytokines and Subsequently Increased Inhibitory ones in Psoriasis: A Prospective Cohort Study. Acta Derm Venereol 2024; 104:adv37555. [PMID: 38738774 PMCID: PMC11107833 DOI: 10.2340/actadv.v104.37555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 04/18/2024] [Indexed: 05/14/2024] Open
Abstract
Abstract is missing (Short communication)
Collapse
Affiliation(s)
- Takemichi Fukasawa
- Department of Dermatology, Psoriasis center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan; Department of Clinical Cannabinoid Research, The University of Tokyo Graduate School of Medicine, Tokyo, Japan.
| | - Asako Yoshizaki-Ogawa
- Department of Dermatology, Psoriasis center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Atsushi Enomoto
- Laboratory of Molecular Radiology, Center for Disease Biology and Integrative Medicine, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Shinichi Sato
- Department of Dermatology, Psoriasis center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Ayumi Yoshizaki
- Department of Dermatology, Psoriasis center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan; Department of Clinical Cannabinoid Research, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
4
|
Fukasawa T, Yamashita T, Enomoto A, Yoshizaki-Ogawa A, Miyagawa K, Sato S, Yoshizaki A. Optimal treatments and outcome measures of palmoplantar pustulosis: A systematic review and network meta-analysis-based comparison of treatment efficacy. J Eur Acad Dermatol Venereol 2024; 38:281-288. [PMID: 37684049 DOI: 10.1111/jdv.19499] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 08/18/2023] [Indexed: 09/10/2023]
Abstract
Few studies have made direct comparisons between treatments for palmoplantar pustulosis (PPP); therefore, it is difficult to select the best treatment for each patient. To determine the best therapy and to compare reported measures of efficacy in clinical trials of systemic treatments for PPP in this systematic review and network meta-analysis. Six databases were used to perform database search on 10 July 2022. Randomized controlled trials (RCTs) were identified through a systematic literature search. The titles and abstracts of articles were initially screened for inclusion by two authors independently using our predetermined criteria. The full texts of selected articles were then independently assessed for inclusion in a blinded fashion. Disagreement between the authors was resolved by consensus. Data were abstracted in duplicate. Random-effects model was accepted to perform network meta-analysis. Assessed Grading of Recommendations Assessment, Development and Evaluation certainty of evidence were performed according to the PRISMA guidelines. The analysis was completed in July 2022. The primary outcome was the change of PPP Area and Severity Index (PPPASI) from baseline and the secondary outcome was the achievement of PPPASI-50 response. Seven RCTs with 567 patients were included. Guselkumab 100 mg was the one with the highest probability of reaching the proposed outcomes (mean difference [MD], -8.00; 95% confidence interval [CI], 4.88-11.11), while the achievement of PPPASI-50 response did not show a significant difference (odds ratio [OR], 3.79; 95% CI, 0.51-28.37). Guselkumab 200 mg was next to 100 mg of reaching the proposed outcomes (MD, -4.71; 95% CI, 2.12-7.30), while the achievement of PPPASI-50 response did not show a significant difference (OR, 2.34; 95% CI, 0.48-11.43). Network meta-analysis showed guselkumab 100 mg was the treatment with the highest probability of reaching both PPPASI and PPPASI-50 outcomes. Absolute PPPASI may be more appropriate as an outcome than PPPASI-50.
Collapse
Affiliation(s)
- Takemichi Fukasawa
- Department of Dermatology, Psoriasis Center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
- Department of Clinical Cannabinoid Research, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Takashi Yamashita
- Department of Dermatology, Psoriasis Center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Atsushi Enomoto
- Laboratory of Molecular Radiology, Center for Disease Biology and Integrative Medicine, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Asako Yoshizaki-Ogawa
- Department of Dermatology, Psoriasis Center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Kiyoshi Miyagawa
- Laboratory of Molecular Radiology, Center for Disease Biology and Integrative Medicine, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Shinichi Sato
- Department of Dermatology, Psoriasis Center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Ayumi Yoshizaki
- Department of Dermatology, Psoriasis Center, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
- Department of Clinical Cannabinoid Research, The University of Tokyo Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
5
|
Trojanowicz M. Impact of nanotechnology on progress of flow methods in chemical analysis: A review. Anal Chim Acta 2023; 1276:341643. [PMID: 37573121 DOI: 10.1016/j.aca.2023.341643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 07/17/2023] [Accepted: 07/18/2023] [Indexed: 08/14/2023]
Abstract
In evolution of instrumentation for analytical chemistry as crucial technological breakthroughs should be considered a common introduction of electronics with all its progress in integration, and then microprocessors which was followed by a widespread computerization. It is seems that a similar role can be attributed to the introduction of various elements of modern nanotechnology, observed with a fast progress since beginning of this century. It concerns all areas of the applications of analytical chemistry, including also progress in flow analysis, which are being developed since the middle of 20th century. Obviously, it should not be omitted the developed earlier and analytically applied planar structures like lipid membranes or self-assembled monolayers They had essential impact prior to discoveries of numerous extraordinary nanoparticles such as fullerenes, carbon nanotubes and graphene, or nanocrystalline semiconductors (quantum dots). Mostly, due to catalytic effects, significantly developed surface and the possibility of easy functionalization, their application in various stages of flow analytical procedures can significantly improve them. The application of new nanomaterials may be used for the development of new detection methods for flow analytical systems in macro-flow setups as well as in microfluidics and lateral flow immunoassay tests. It is also advantageous that quick flow conditions of measurements may be helpful in preventing unfavorable agglomeration of nanoparticles. A vast literature published already on this subject (e.g. almost 1000 papers about carbon nanotubes and flow-injection analytical systems) implies that for this reviews it was necessary to make an arbitrary selection of reported examples of this trend, focused mainly on achievements reported in the recent decade.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Techniques, Institute of Nuclear Chemistry and Technology, Warsaw, Poland; Department of Chemistry, University of Warsaw, Poland.
| |
Collapse
|
6
|
Kazoe Y, Ikeda K, Mino K, Morikawa K, Mawatari K, Kitamori T. Quantitative characterization of liquids flowing in geometrically controlled sub-100 nm nanofluidic channels. ANAL SCI 2023; 39:779-784. [PMID: 36884162 DOI: 10.1007/s44211-023-00311-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 02/23/2023] [Indexed: 03/09/2023]
Abstract
With development of nanotechnologies, applications exploiting nanospaces such as single-molecule analysis and high-efficiency separation have been reported, and understanding properties of fluid flows in 101 nm to 102 nm scale spaces becomes important. Nanofluidics has provided a platform of nanochannels with defined size and geometry, and revealed various unique liquid properties including higher water viscosity with dominant surface effects in 102 nm spaces. However, experimental investigation of fluid flows in 101 nm spaces is still difficult owing to lack of fabrication procedure for 101 nm nanochannels with smooth walls and precisely controlled geometry. In the present study, we established a top-down fabrication process to realize fused-silica nanochannels with 101 nm scale size, 100 nm roughness and rectangular cross-sectional shape with an aspect ratio of 1. Utilizing a method of mass flowmetry developed by our group, accurate measurements of ultra-low flow rates in sub-100 nm nanochannels with sizes of 70 nm and 100 nm were demonstrated. The results suggested that the viscosity of water in these sub-100 nm nanochannels was approximately 5 times higher than that in the bulk, while that of dimethyl sulfoxide was similar to the bulk value. The obtained liquid permeability in the nanochannels can be explained by a hypothesis of loosely structured liquid phase near the wall generated by interactions between the surface silanol groups and protic solvent molecules. The present results suggest the importance of considering the species of solvent, the surface chemical groups, and the size and geometry of nanospaces when designing nanofluidic devices and membranes.
Collapse
Affiliation(s)
- Yutaka Kazoe
- Department of System Design Engineering, Faculty of Science and Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku, Yokohama, 223-8522, Japan.
| | - Keisuke Ikeda
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Kensuke Mino
- Department of System Design Engineering, Faculty of Science and Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku, Yokohama, 223-8522, Japan
| | - Kyojiro Morikawa
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu, 300044, Taiwan
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Kazuma Mawatari
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Takehiko Kitamori
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu, 300044, Taiwan
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, 221 00, Lund, Sweden
| |
Collapse
|
7
|
Stability of enzyme immobilized on the nanofluidic channel surface. ANAL SCI 2023; 39:251-255. [PMID: 36670328 DOI: 10.1007/s44211-023-00272-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Accepted: 01/06/2023] [Indexed: 01/21/2023]
Abstract
The lifetime of an enzyme is critical to prevent system failure and optimize maintenance schedules in biological and analytical chemistry. The lifetime metrics of an enzyme can be evaluated from enzyme activity in terms of catalytic cycles per enzyme at various storage times. Trypsin, which is a gold-standard enzyme in proteomics, has been known to decrease activity due to self-digestion. To improve the activity of trypsin, enzyme reactors have developed by immobilizing in micro and nanospace. However, an evaluation method for the catalytic cycle has not been established due to major issues such as nonuniform space, unstable liquid transport, and self-digestion during immobilization in conventional work. To solve these issues, we have previously developed an ultra-fast enzyme reactor with a well-defined nanofabrication method, stable liquid transport, and partial enzyme modification. Here, we aimed to investigate catalytic cycles in a nanochannel. To extend enzyme lifetime efficiently, we have evaluated the optimal immobilization process and catalytic cycles of trypsin. As a result, immobilized enzyme densities by the trypsinogen immobilization process were increased at all concentrations compared to the trypsin immobilization process. To evaluate the lifetime of trypsin, the immobilized enzyme densities and activities were almost the same before and after 72 h of enzyme storage, and the calculated catalytic cycles were 1740. These results indicated that self-digestion of the immobilized enzyme was highly suppressed. Consequently, the reaction efficiency has been evaluated depending on the catalytic cycles from the substrate for the first time, while preventing self-digestion by trypsin.
Collapse
|
8
|
Sano H, Kazoe Y, Ohta R, Shimizu H, Morikawa K, Kitamori T. Nanofluidic analytical system integrated with nanochannel open/close valves for enzyme-linked immunosorbent assay. LAB ON A CHIP 2023; 23:727-736. [PMID: 36484269 DOI: 10.1039/d2lc00881e] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
There have been significant advances in the field of nanofluidics, and novel technologies such as single-cell analysis have been demonstrated. Despite the evident advantages of nanofluidics, fluid control in nanochannels for complicated analyses is extremely difficult because the fluids are currently manipulated by maintaining the balance of driving pressure. To address this issue, the use of valves will be essential. Our group previously developed a nanochannel open/close valve utilizing glass deformation, but this has not yet been integrated into nanofluidic devices for analytical applications. In the present study, a nanofluidic analytical system integrated with multiple nanochannel open/close valves was developed. This system consists of eight pneumatic pumps, seven nanochannel open/close valves combined with piezoelectric actuators, and an ultra-high sensitivity detector for non-fluorescent molecules. For simultaneous actuation of multiple valves, a device holder was designed that prevented deformation of the entire device caused by operating the valves. A system was subsequently devised to align each valve and actuator with a precision of better than 20 μm to permit the operation of valves. The developed analytical system was verified by analyzing IL-6 molecules using an enzyme-linked immunosorbent assay. Fluid operations such as sample injection, pL-level aliquot sampling and flow switching were accomplished in this device simply by opening/closing specific valves, and a sample consisting of approximately 1500 IL-6 molecules was successfully detected. This study is expected to significantly improve the usability of nanofluidic analytical devices and lead to the realization of sophisticated analytical techniques such as single-cell proteomics.
Collapse
Affiliation(s)
- Hiroki Sano
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Yutaka Kazoe
- Department of System Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku, Yokohama, Kanagawa 223-8522, Japan.
| | - Ryoichi Ohta
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Hisashi Shimizu
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Kyojiro Morikawa
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan.
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Takehiko Kitamori
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan.
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, 221 00 Lund, Sweden
| |
Collapse
|
9
|
Smirnova A, Ohta R, Mori E, Shimizu H, Morikawa K, Kitamori T. Enzyme-linked immunosorbent assay using thin-layered microfluidics with perfect capture of the target protein. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:675-684. [PMID: 36655604 DOI: 10.1039/d2ay01686a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
We developed a process for enzyme-linked immunosorbent assay on a glass microchip via the use of a thin-layered microfluidic channel. This channel possesses a high aspect ratio (width/depth ∼200) and has an antibody layer immobilized directly on the channel surface. A depth of several microns and an excessive width and length (mm scale) of the channel provide a large-volume capacity (102 nL) and maximum capture efficiency of the analyte for a high level of detection sensitivity (102 pg mL-1). The developed reusable immunosensor has demonstrated high-performance characteristics by requiring less than 50 μL of sample and providing analysis in less than 25 min. This new method could impact the development of point-of-care devices for biomedical applications.
Collapse
Affiliation(s)
- Adelina Smirnova
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Ryoichi Ohta
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Emi Mori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Hisashi Shimizu
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Kyojiro Morikawa
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan, Republic of China
| | - Takehiko Kitamori
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan, Republic of China
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund 221 00, Sweden
| |
Collapse
|
10
|
Fukasawa T, Yoshizaki-Ogawa A, Enomoto A, Miyagawa K, Sato S, Yoshizaki A. Involvement of Molecular Mechanisms between T/B Cells and IL-23: From Palmoplantar Pustulosis to Autoimmune Diseases. Int J Mol Sci 2022; 23:8261. [PMID: 35897837 PMCID: PMC9332852 DOI: 10.3390/ijms23158261] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 07/22/2022] [Accepted: 07/25/2022] [Indexed: 11/17/2022] Open
Abstract
Palmoplantar pustulosis (PPP) is a disease that causes recurrent blisters and aseptic pustules on the palms and soles. It has been suggested that both innate and acquired immunity are involved. In particular, based on the tonsils and basic experiments, it has been assumed that T and B cells are involved in its pathogenesis. In addition, the results of clinical trials have suggested that IL-23 is closely related to the pathogenesis. This review describes PPP and the genetic background, the factors involved in the onset and exacerbation of disease and its relation to the molecular mechanism. In addition, we describe the usefulness of biological therapy and its implications in relation to the importance in pathology, the pathogenesis of PPP, the importance of the role of the IL-23-Th17 axis and IL-36 in PPP. Furthermore, we describe an animal experimental model of PPP, the efficacy and mechanism of action of guselkumab, an anti-IL-23 antibody, the latest research, and finally the possibility for it to be effective for other autoimmune diseases.
Collapse
Affiliation(s)
- Takemichi Fukasawa
- Department of Dermatology, The University of Tokyo Graduate School of Medicine, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| | - Asako Yoshizaki-Ogawa
- Department of Dermatology, The University of Tokyo Graduate School of Medicine, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| | - Atsushi Enomoto
- Laboratory of Molecular Radiology, Center for Disease Biology and Integrative Medicine, The University of Tokyo Graduate School of Medicine, Tokyo 113-8655, Japan; (A.E.); (K.M.)
| | - Kiyoshi Miyagawa
- Laboratory of Molecular Radiology, Center for Disease Biology and Integrative Medicine, The University of Tokyo Graduate School of Medicine, Tokyo 113-8655, Japan; (A.E.); (K.M.)
| | - Shinichi Sato
- Department of Dermatology, The University of Tokyo Graduate School of Medicine, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| | - Ayumi Yoshizaki
- Department of Dermatology, The University of Tokyo Graduate School of Medicine, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| |
Collapse
|
11
|
Takagi Y, Kazoe Y, Morikawa K, Kitamori T. Femtoliter-Droplet Mass Spectrometry Interface Utilizing Nanofluidics for Ultrasmall and High-Sensitivity Analysis. Anal Chem 2022; 94:10074-10081. [PMID: 35793145 DOI: 10.1021/acs.analchem.2c01069] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In the fields of biology and medicine, comprehensive protein analysis at the single-cell level utilizing mass spectrometry (MS) with pL sample volumes and zmol to amol sensitivity is required. Our group has developed nanofluidic analytical pretreatment methods that exploit nanochannels for downsizing chemical unit operations to fL-pL volumes. In the field of analytical instruments, mass spectrometers have advanced to achieve ultrahigh sensitivity. However, a method to interface between fL-pL pretreatments and mass spectrometers without sample loss and dispersion is still challenging. In this study, we developed an MS interface utilizing nanofluidics to achieve high-sensitivity detection. After charging analyte molecules by an applied voltage through an electrode, the liquid sample was converted to fL droplets by a nanofluidic device. Considering the inertial force that acts on the droplets, the droplets were carried with a controlled trajectory, even in turbulent air flow, and injected into a mass spectrometer with 100% efficiency. A module for heat transfer was designed and constructed, by which all of the injected droplets were vaporized to produce gas-phase ions. The detection of caffeine ions was achieved at a limit of detection of 1.52 amol, which was 290 times higher than a conventional MS interface by electrospray ionization with sample dispersion combined with a similar mass spectrometer. Therefore, sensitivity that was 2 orders of magnitude higher could be realized due to the 100% sample injection rate. The present study provides a new methodology for the analysis of ultrasmall samples with high-sensitivity, such as protein molecules produced from a single cell.
Collapse
Affiliation(s)
- Yuto Takagi
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Yutaka Kazoe
- Department of System Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan
| | - Kyojiro Morikawa
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.,Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan R. O. C
| | - Takehiko Kitamori
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.,Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan R. O. C
| |
Collapse
|
12
|
Fukasawa T, Yoshizaki-Ogawa A, Enomoto A, Miyagawa K, Sato S, Yoshizaki A. Pharmacotherapy of Itch-Antihistamines and Histamine Receptors as G Protein-Coupled Receptors. Int J Mol Sci 2022; 23:6579. [PMID: 35743023 PMCID: PMC9223628 DOI: 10.3390/ijms23126579] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/05/2022] [Accepted: 06/07/2022] [Indexed: 02/05/2023] Open
Abstract
Itching can decrease quality of life and exacerbate skin symptoms due to scratching. Itching not only contributes to disease progression but also triggers complications such as skin infections and eye symptoms. Therefore, controlling itching is very important in therapeutic management. In addition to the well-known histamine, IL-31, IL-4 and IL-13 have recently been reported as factors that induce itching. Itching may also be caused by factors other than these histamines. However, we do not know the extent to which these factors are involved in each disease. In addition, the degree of involvement is likely to vary among individuals. To date, antihistamines have been widely used to treat itching and are often effective, suggesting that histamine is more or less involved in itchy diseases. This review discusses the ligand-receptor perspective and describes the dynamics of G protein-coupled receptors, their role as biased agonists, their role as inverse agonists, proactive antihistamine therapy, and drug selection with consideration of impaired performance and anti-PAF effects.
Collapse
Affiliation(s)
- Takemichi Fukasawa
- Department of Dermatology, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| | - Asako Yoshizaki-Ogawa
- Department of Dermatology, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| | - Atsushi Enomoto
- Laboratory of Molecular Radiology, Center for Disease Biology and Integrative Medicine, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan; (A.E.); (K.M.)
| | - Kiyoshi Miyagawa
- Laboratory of Molecular Radiology, Center for Disease Biology and Integrative Medicine, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan; (A.E.); (K.M.)
| | - Shinichi Sato
- Department of Dermatology, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| | - Ayumi Yoshizaki
- Department of Dermatology, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan; (T.F.); (A.Y.-O.); (S.S.)
| |
Collapse
|
13
|
Yamamoto K, Morikawa K, Shimizu H, Sano H, Kazoe Y, Kitamori T. Accelerated protein digestion and separation with picoliter volume utilizing nanofluidics. LAB ON A CHIP 2022; 22:1162-1170. [PMID: 35133382 DOI: 10.1039/d1lc00923k] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Single cell analyses can provide critical biological insight into cellular heterogeneity. In particular, the proteome, which governs cell functions, is much more difficult to analyze because it is principally impossible to amplify proteins compared to nucleic acids. The most promising approach to single cell proteomics is based on the liquid chromatography mass spectrometry (LC-MS) platform. However, pretreatments before MS detection have two critical issues for single cell analysis: analyte loss as a result of adsorption and artifacts due to the duration of analysis. This is a serious problem because single cells have a limited number of protein molecules and a small volume. To solve these issues, we developed an integrated nanofluidic device to manipulate samples on a femtoliter to picoliter (fL-pL) scale to achieve high-throughput analysis via suppressing analyte loss. This device can perform tryptic digestion, chromatographic separation, and non-labeled detection with high consistency. In addition, we introduced an open/close valve by physical deformation of glass on a nanometer scale to independently modify the nanochannel surfaces and control sample aliquots. The injection system equipped with this valve achieved an injection volume of 1.0 ± 0.1 pL. By using this integrated device, we found that the chromatogram of bulk-digestion for 12 hours resembled that of 15 min-digestion in the nanochannel, which indicated that these conditions reached a similar state of digestion. Therefore, an integrated device for ultra-fast protein analysis was developed on a 1 pL scale for the first time.
Collapse
Affiliation(s)
- Koki Yamamoto
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Kyojiro Morikawa
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Hisashi Shimizu
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Hiroki Sano
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Yutaka Kazoe
- Department of System Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku, Kanagawa 223-8522, Japan
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan, Republic of China
| |
Collapse
|
14
|
Fukasawa T, Yoshizaki A, Ebata S, Yoshizaki-Ogawa A, Asano Y, Enomoto A, Miyagawa K, Kazoe Y, Mawatari K, Kitamori T, Sato S. Single-cell-level protein analysis revealing the roles of autoantigen-reactive B lymphocytes in autoimmune disease and the murine model. eLife 2021; 10:e67209. [PMID: 34854378 PMCID: PMC8639144 DOI: 10.7554/elife.67209] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 11/21/2021] [Indexed: 12/21/2022] Open
Abstract
Despite antigen affinity of B cells varying from cell to cell, functional analyses of antigen-reactive B cells on individual B cells are missing due to technical difficulties. Especially in the field of autoimmune diseases, promising pathogenic B cells have not been adequately studied to date because of its rarity. In this study, functions of autoantigen-reactive B cells in autoimmune disease were analyzed at the single-cell level. Since topoisomerase I is a distinct autoantigen, we targeted systemic sclerosis as autoimmune disease. Decreased and increased affinities for topoisomerase I of topoisomerase I-reactive B cells led to anti-inflammatory and pro-inflammatory cytokine production associated with the inhibition and development of fibrosis, which is the major symptom of systemic sclerosis. Furthermore, inhibition of pro-inflammatory cytokine production and increased affinity of topoisomerase I-reactive B cells suppressed fibrosis. These results indicate that autoantigen-reactive B cells contribute to the disease manifestations in autoimmune disease through their antigen affinity.
Collapse
Affiliation(s)
- Takemichi Fukasawa
- Department of Dermatology, The University of Tokyo Graduate School of MedicineTokyoJapan
| | - Ayumi Yoshizaki
- Department of Dermatology, The University of Tokyo Graduate School of MedicineTokyoJapan
| | - Satoshi Ebata
- Department of Dermatology, The University of Tokyo Graduate School of MedicineTokyoJapan
| | - Asako Yoshizaki-Ogawa
- Department of Dermatology, The University of Tokyo Graduate School of MedicineTokyoJapan
| | - Yoshihide Asano
- Department of Dermatology, The University of Tokyo Graduate School of MedicineTokyoJapan
| | - Atsushi Enomoto
- Laboratory of Radiology and Biomedical Engineering, The University of Tokyo Graduate School of MedicineTokyoJapan
| | - Kiyoshi Miyagawa
- Laboratory of Radiology and Biomedical Engineering, The University of Tokyo Graduate School of MedicineTokyoJapan
| | - Yutaka Kazoe
- Department of System Design Engineering, Keio university, Faculty of Science and technologyTokyoJapan
| | - Kazuma Mawatari
- Department of Applied Chemistry, The University of Tokyo Graduate School of EngineeringTokyoJapan
| | - Takehiko Kitamori
- Department of Mechanical Engineering, The University of Tokyo Graduate School of EngineeringTokyoJapan
| | - Shinichi Sato
- Department of Dermatology, The University of Tokyo Graduate School of MedicineTokyoJapan
| |
Collapse
|
15
|
Morikawa K, Kazumi H, Tsuyama Y, Ohta R, Kitamori T. Surface Patterning of Closed Nanochannel Using VUV Light and Surface Evaluation by Streaming Current. MICROMACHINES 2021; 12:mi12111367. [PMID: 34832779 PMCID: PMC8623798 DOI: 10.3390/mi12111367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/02/2021] [Accepted: 11/04/2021] [Indexed: 11/16/2022]
Abstract
In nanofluidics, surface control is a critical technology because nanospaces are surface-governed spaces as a consequence of their extremely high surface-to-volume ratio. Various surface patterning methods have been developed, including patterning on an open substrate and patterning using a liquid modifier in microchannels. However, the surface patterning of a closed nanochannel is difficult. In addition, the surface evaluation of closed nanochannels is difficult because of a lack of appropriate experimental tools. In this study, we verified the surface patterning of a closed nanochannel by vacuum ultraviolet (VUV) light and evaluated the surface using streaming-current measurements. First, the C18 modification of closed nanochannels was confirmed by Laplace pressure measurements. In addition, no streaming-current signal was detected for the C18-modified surface, confirming the successful modification of the nanochannel surface with C18 groups. The C18 groups were subsequently decomposed by VUV light, and the nanochannel surface became hydrophilic because of the presence of silanol groups. In streaming-current measurements, the current signals increased in amplitude with increasing VUV light irradiation time, indicating the decomposition of the C18 groups on the closed nanochannel surfaces. Finally, hydrophilic/hydrophobic patterning by VUV light was performed in a nanochannel. Capillary filling experiments confirmed the presence of a hydrophilic/hydrophobic interface. Therefore, VUV patterning in a closed nanochannel was demonstrated, and the surface of a closed nanochannel was successfully evaluated using streaming-current measurements.
Collapse
Affiliation(s)
- Kyojiro Morikawa
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan; (H.K.); (R.O.)
- Correspondence: (K.M.); (T.K.)
| | - Haruki Kazumi
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan; (H.K.); (R.O.)
| | - Yoshiyuki Tsuyama
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan;
| | - Ryoichi Ohta
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan; (H.K.); (R.O.)
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan; (H.K.); (R.O.)
- Collaborative Research Organization for Micro and Nano Multifunctional Devices (NMfD), The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
- Institute of Nanoengineering and Microsystems (iNEMS), Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan
- Correspondence: (K.M.); (T.K.)
| |
Collapse
|
16
|
Kazoe Y, Shibata K, Kitamori T. Super-Resolution Defocusing Nanoparticle Image Velocimetry Utilizing Spherical Aberration for Nanochannel Flows. Anal Chem 2021; 93:13260-13267. [PMID: 34559530 DOI: 10.1021/acs.analchem.1c02575] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Understanding fluid flows and mass transport in nanospaces is becoming important with recent advances in nanofluidic analytical devices utilizing nanopores and nanochannels. In the present study, we developed a super-resolution and fast particle tracking method utilizing defocusing images with spherical aberration and demonstrated the measurement of nanochannel flow. Since the spherical aberration generates the defocusing nanoparticle image with diffraction rings, the position of fluorescent nanoparticles was determined from the radius of the diffraction ring. Effects of components of an optical system on the diffraction ring of the defocusing image were investigated and optimized to achieve the spatial resolution exceeding the optical diffraction limit. We found that there is an optimal magnitude of spherical aberration to enhance the spatial resolution. Furthermore, we confirmed that nanoparticles with diameters in the order of 101 nm, which is much smaller than the light wavelength, do not affect the defocusing images and the spatial resolution because such nanoparticles can be regarded as point light sources. At optimized conditions, we achieved a spatial resolution of 19 nm and a temporal resolution of 160 μs, which are sufficient for the nanochannel flow measurements. We succeeded in the measurement of pressure-driven flow in a nanochannel with a depth of 370 nm using 67 nm fluorescent nanoparticles. The measured nanoparticle velocities exhibited a parabolic flow profile with a slip velocity even at the hydrophilic glass surface but with an average velocity similar to the Hagen-Poiseuille law. The method will accelerate researches in the nanofluidics and other related fields.
Collapse
Affiliation(s)
- Yutaka Kazoe
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.,Department of System Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku, Yokohama 223-8522, Japan
| | - Kazuki Shibata
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.,Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.,Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan, ROC
| |
Collapse
|
17
|
Morikawa K, Ohta R, Mawatari K, Kitamori T. Metal-Free Fabrication of Fused Silica Extended Nanofluidic Channel to Remove Artifacts in Chemical Analysis. MICROMACHINES 2021; 12:mi12080917. [PMID: 34442539 PMCID: PMC8399996 DOI: 10.3390/mi12080917] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 07/29/2021] [Accepted: 07/30/2021] [Indexed: 11/16/2022]
Abstract
In microfluidics, especially in nanofluidics, nanochannels with functionalized surfaces have recently attracted attention for use as a new tool for the investigation of chemical reaction fields. Molecules handled in the reaction field can reach the single-molecule level due to the small size of the nanochannel. In such surroundings, contamination of the channel surface should be removed at the single-molecule level. In this study, it was assumed that metal materials could contaminate the nanochannels during the fabrication processes; therefore, we aimed to develop metal-free fabrication processes. Fused silica channels 1000 nm-deep were conventionally fabricated using a chromium mask. Instead of chromium, electron beam resists more than 1000 nm thick were used and the lithography conditions were optimized. From the results of optimization, channels with 1000 nm scale width and depth were fabricated on fused silica substrates without the use of a chromium mask. In nanofluidic experiments, an oxidation reaction was observed in a device fabricated by conventional fabrication processes using a chromium mask. It was found that Cr6+ remained on the channel surfaces and reacted with chemicals in the liquid phase in the extended nanochannels; this effect occurred at least to the micromolar level. In contrast, the device fabricated with metal-free processes was free of artifacts induced by the presence of chromium. The developed fabrication processes and results of this study will be a significant contribution to the fundamental technologies employed in the fields of microfluidics and nanofluidics.
Collapse
Affiliation(s)
- Kyojiro Morikawa
- Collaborative Research Organization for Micro and Nano Multifunctional Devices (NMfD), The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Ryoichi Ohta
- Collaborative Research Organization for Micro and Nano Multifunctional Devices (NMfD), The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Kazuma Mawatari
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Takehiko Kitamori
- Collaborative Research Organization for Micro and Nano Multifunctional Devices (NMfD), The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
- Institute of Nanoengineering and Microsystems (iNEMS), Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan
| |
Collapse
|
18
|
Tsuyama Y, Morikawa K, Mawatari K. Integration of sequential analytical processes into sub-100 nm channels: volumetric sampling, chromatographic separation, and label-free molecule detection. NANOSCALE 2021; 13:8855-8863. [PMID: 33949427 DOI: 10.1039/d0nr08385b] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The progress of nanotechnology has developed nanofluidic devices utilizing nanochannels with a width and/or depth of sub-100 nm (101 nm channels), and several experiments have been implemented in ultra-small spaces comparable to DNAs and proteins. However, current experiments utilizing 101 nm channels focus on a single function or operation; integration of multiple analytical operations into 101 nm channels using nanofluidic circuits and fluidic control has yet to be realized despite the advantage of nanochannels. Herein, we report the establishment of a label-free molecule detection method for 101 nm channels and demonstration of sequential analytical processes using integrated nanofluidic devices. Our absorption-based detection method called photothermal optical diffraction (POD) enables non-invasive label-free molecule detection in 101 nm channels for the first time, and the limit of detection (LOD) of 1.8 μM is achieved in 70 nm wide and deep nanochannels, which corresponds to 7.5 molecules in the detection volume of 7 aL. As a demonstration of sampling in 101 nm channels, aL-fL volumetric sampling is performed using 90 nm deep cross-shaped nanochannels and pressure-driven fluidic control from three directions. Finally, the POD and volumetric sampling are combined with nanochannel chromatography, and separation analysis in 101 nm channels is demonstrated. The experimental results reported in this paper will contribute to the advances in 101 nm fluidic devices which have the potential to provide a novel platform for chemical/biological analyses.
Collapse
Affiliation(s)
- Yoshiyuki Tsuyama
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | | | | |
Collapse
|
19
|
Yamamoto K, Ota N, Tanaka Y. Nanofluidic Devices and Applications for Biological Analyses. Anal Chem 2021; 93:332-349. [PMID: 33125221 DOI: 10.1021/acs.analchem.0c03868] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Koki Yamamoto
- Laboratory for Integrated Biodevice, Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Nobutoshi Ota
- Laboratory for Integrated Biodevice, Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Yo Tanaka
- Laboratory for Integrated Biodevice, Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
20
|
Affiliation(s)
- Keke Hu
- Department of Chemistry and Molecular Biology, University of Gothenburg, Kemivägen 10, 41296 Gothenburg, Sweden
| | - Tho D. K. Nguyen
- Department of Chemistry and Molecular Biology, University of Gothenburg, Kemivägen 10, 41296 Gothenburg, Sweden
| | - Stefania Rabasco
- Department of Chemistry and Molecular Biology, University of Gothenburg, Kemivägen 10, 41296 Gothenburg, Sweden
| | - Pieter E. Oomen
- Department of Chemistry and Molecular Biology, University of Gothenburg, Kemivägen 10, 41296 Gothenburg, Sweden
- ParaMedir B.V., 1e Energieweg 13, 9301 LK Roden, The Netherlands
| | - Andrew G. Ewing
- Department of Chemistry and Molecular Biology, University of Gothenburg, Kemivägen 10, 41296 Gothenburg, Sweden
| |
Collapse
|
21
|
Morikawa K, Kazoe Y, Takagi Y, Tsuyama Y, Pihosh Y, Tsukahara T, Kitamori T. Advanced Top-Down Fabrication for a Fused Silica Nanofluidic Device. MICROMACHINES 2020; 11:E995. [PMID: 33182488 PMCID: PMC7697862 DOI: 10.3390/mi11110995] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 10/29/2020] [Accepted: 10/29/2020] [Indexed: 02/07/2023]
Abstract
Nanofluidics have recently attracted significant attention with regard to the development of new functionalities and applications, and producing new functional devices utilizing nanofluidics will require the fabrication of nanochannels. Fused silica nanofluidic devices fabricated by top-down methods are a promising approach to realizing this goal. Our group previously demonstrated the analysis of a living single cell using such a device, incorporating nanochannels having different sizes (102-103 nm) and with branched and confluent structures and surface patterning. However, fabrication of geometrically-controlled nanochannels on the 101 nm size scale by top-down methods on a fused silica substrate, and the fabrication of micro-nano interfaces on a single substrate, remain challenging. In the present study, the smallest-ever square nanochannels (with a size of 50 nm) were fabricated on fused silica substrates by optimizing the electron beam exposure time, and the absence of channel breaks was confirmed by streaming current measurements. In addition, micro-nano interfaces between 103 nm nanochannels and 101 μm microchannels were fabricated on a single substrate by controlling the hydrophobicity of the nanochannel surfaces. A micro-nano interface for a single cell analysis device, in which a nanochannel was connected to a 101 μm single cell chamber, was also fabricated. These new fabrication procedures are expected to advance the basic technologies employed in the field of nanofluidics.
Collapse
Affiliation(s)
- Kyojiro Morikawa
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; (Y.K.); (Y.T.); (Y.P.)
| | - Yutaka Kazoe
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; (Y.K.); (Y.T.); (Y.P.)
| | - Yuto Takagi
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; (Y.K.); (Y.T.); (Y.P.)
| | - Yoshiyuki Tsuyama
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan;
| | - Yuriy Pihosh
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; (Y.K.); (Y.T.); (Y.P.)
| | - Takehiko Tsukahara
- Laboratory for Advanced Nuclear Energy, Institute of Innovative Research, Tokyo Institute of Technology, 2-12-1-N1-6, Ookayama, Meguro-ku, Tokyo 152-8550, Japan;
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; (Y.K.); (Y.T.); (Y.P.)
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan;
| |
Collapse
|
22
|
Tsuyama Y, Mawatari K. Concentration Determination at a Countable Molecular Level in Nanofluidics by Solvent-Enhanced Photothermal Optical Diffraction. Anal Chem 2020; 92:14366-14372. [DOI: 10.1021/acs.analchem.0c02024] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Yoshiyuki Tsuyama
- Department of Bioengineering, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Kazuma Mawatari
- Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan
| |
Collapse
|
23
|
Shoda K, Tanaka M, Mino K, Kazoe Y. A Simple Low-Temperature Glass Bonding Process with Surface Activation by Oxygen Plasma for Micro/Nanofluidic Devices. MICROMACHINES 2020; 11:E804. [PMID: 32854246 PMCID: PMC7570177 DOI: 10.3390/mi11090804] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 08/11/2020] [Accepted: 08/23/2020] [Indexed: 12/18/2022]
Abstract
The bonding of glass substrates is necessary when constructing micro/nanofluidic devices for sealing micro- and nanochannels. Recently, a low-temperature glass bonding method utilizing surface activation with plasma was developed to realize micro/nanofluidic devices for various applications, but it still has issues for general use. Here, we propose a simple process of low-temperature glass bonding utilizing typical facilities available in clean rooms and applied it to the fabrication of micro/nanofluidic devices made of different glasses. In the process, the substrate surface was activated with oxygen plasma, and the glass substrates were placed in contact in a class ISO 5 clean room. The pre-bonded substrates were heated for annealing. We found an optimal concentration of oxygen plasma and achieved a bonding energy of 0.33-0.48 J/m2 in fused-silica/fused-silica glass bonding. The process was applied to the bonding of fused-silica glass and borosilicate glass, which is generally used in optical microscopy, and revealed higher bonding energy than fused-silica/fused-silica glass bonding. An annealing temperature lower than 200 °C was necessary to avoid crack generation by thermal stress due to the different thermal properties of the glasses. A fabricated micro/nanofluidic device exhibited a pressure resistance higher than 600 kPa. This work will contribute to the advancement of micro/nanofluidics.
Collapse
Affiliation(s)
| | | | | | - Yutaka Kazoe
- Department of System Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku, Kanagawa 223-8522, Japan; (K.S.); (M.T.); (K.M.)
| |
Collapse
|
24
|
Kazoe Y, Mawatari K, Li L, Emon H, Miyawaki N, Chinen H, Morikawa K, Yoshizaki A, Dittrich PS, Kitamori T. Lipid Bilayer-Modified Nanofluidic Channels of Sizes with Hundreds of Nanometers for Characterization of Confined Water and Molecular/Ion Transport. J Phys Chem Lett 2020; 11:5756-5762. [PMID: 32633535 DOI: 10.1021/acs.jpclett.0c01084] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Water inside and between cells with dimensions on the order of 101-103 nm such as synaptic clefts and mitochondria is thought to be important to biological functions, such as signal transmissions and energy production. However, the characterization of water in such spaces has been difficult owing to the small size and complexity of cellular environments. To this end, we proposed and fabricated a biomimetic nanospace exploiting nanofluidic channels with defined dimensions of hundreds of nanometers and controlled environments. A method of modifying a glass nanochannel with a unilamellar lipid bilayer was developed. We revealed that 2.1-5.6 times higher viscosity of water arises in a 200 nm sized biomimetic nanospace by interactions between water molecules and the lipid bilayer surface and significantly affects the molecular/ion transport that is required for the biological functions. The proposed method provides both a technical breakthrough and new findings to the fields of physical chemistry and biology.
Collapse
Affiliation(s)
- Yutaka Kazoe
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Kazuma Mawatari
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Lixiao Li
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Hisaki Emon
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Naoya Miyawaki
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Hiroyuki Chinen
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Kyojiro Morikawa
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Ayumi Yoshizaki
- Department of Dermatology, School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Petra S Dittrich
- Department of Biosystems Science and Engineering, ETH Zurich, Mattenstrasse 26, CH-4058 Basel, Switzerland
| | - Takehiko Kitamori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| |
Collapse
|
25
|
Ding G, Wang J, Wang L, Zou J, Tian P, Zhang Y, Pan X, Li D. Quantitative viability detection for a single microalgae cell by two-level photoexcitation. Analyst 2020; 145:3931-3938. [PMID: 32314762 DOI: 10.1039/d0an00450b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel method for quantitative detection of the viability of a single microalgae cell by two-level photoexcitation is proposed in this paper. This method overcomes the difficulty of traditional methods in determining the cell viability by a fixed standard under a single photoexcitation. It is experimentally confirmed that this method is not limited by the species, morphology, size and structure of microalgae cells. An evaluation criterion of universal applicability is presented for the assessment of cell viability based on the large amount of experimental data. To the best of our knowledge, this is the first time that the relative fluorescence yield ratio Fr has been used to characterize the viability of single microalgae cells during cell migration. By using the relative fluorescence yield ratio, this method does not require the intensity of the excitation light to be very low for the assessment of the fluorescence yield of a dark-adapted microalgae cell, nor to be very strong to reach the saturated light level to assess the maximum fluorescence yield. Therefore, this method greatly reduces the technical difficulties of developing a sensor device. Well balanced portability, accuracy and universal applicability make it suitable for on-site real-time detection.
Collapse
Affiliation(s)
- Gege Ding
- Center of Microfluidic Optoelectronic Sensing, Dalian Maritime University, Dalian, 116026, China.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Fujiwara S, Morikawa K, Endo T, Hisamoto H, Sueyoshi K. Size Sorting of Exosomes by Tuning the Thicknesses of the Electric Double Layers on a Micro-Nanofluidic Device. MICROMACHINES 2020; 11:mi11050458. [PMID: 32354140 PMCID: PMC7281254 DOI: 10.3390/mi11050458] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 04/26/2020] [Accepted: 04/27/2020] [Indexed: 12/25/2022]
Abstract
Exosomes, a type of extracellular vesicle with a diameter of 30–150 nm, perform key biological functions such as intercellular communication. Recently, size sorting of exosomes has received increasing attention in order to clarify the correlation between their size and components. However, such sorting remains extremely difficult. Here, we propose to sort their size by controlling their electrokinetic migration in nanochannels in a micro-nanofluidic device, which is achieved by tuning the thickness of the electric double layers in the nanochannels. This approach was demonstrated experimentally for exosomes smaller than 250 nm. Using different running buffer concentrations (1 × 10−3, 1 × 10−4, and 1 × 10−5 M), most of the exosomes larger than 140, 110, and 80 nm were successfully cut off at the downstream of the nanochannels, respectively. Therefore, it is clarified that the proposed method is applicable for the size sorting of exosomes.
Collapse
Affiliation(s)
- Satoko Fujiwara
- Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, Osaka 599-8531, Japan; (S.F.); (T.E.); (H.H.)
| | - Kyojiro Morikawa
- Department of Applied Chemistry, School of Engineering, University of Tokyo, Tokyo 113-0033, Japan;
| | - Tatsuro Endo
- Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, Osaka 599-8531, Japan; (S.F.); (T.E.); (H.H.)
| | - Hideaki Hisamoto
- Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, Osaka 599-8531, Japan; (S.F.); (T.E.); (H.H.)
| | - Kenji Sueyoshi
- Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, Osaka 599-8531, Japan; (S.F.); (T.E.); (H.H.)
- Japan Science and Technology Agency (JST), Precursory Research for Embryonic Science and Technology (PRESTO), Tokyo 102-8666, Japan
- Correspondence: ; Tel.: +81-72-254-9477
| |
Collapse
|
27
|
Nakao T, Kazoe Y, Morikawa K, Lin L, Mawatari K, Kitamori T. Femtoliter Volumetric Pipette and Flask Utilizing Nanofluidics. Analyst 2020; 145:2669-2675. [PMID: 32049074 DOI: 10.1039/c9an02258a] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Microfluidics has achieved integration of analytical processes in microspaces and realized miniaturized analyses in fields such as chemistry and biology. We have proposed a general concept of integration and extended this concept to the 10-1000 nm scale exploring ultimate analytical performances (e.g. immunoassay of a single-protein molecule). However, a sampling method is still challenging for nanofluidics despite its importance in analytical chemistry. In this study, we developed a femtoliter (fL) sampling method for volume measurement and sample transport. Traditionally, sampling has been performed using a volumetric pipette and flask. In this research, a nanofluidic device consisting of a femtoliter volumetric pipette and flask was fabricated on glass substrates. Since gravity, which is exploited in bulk fluidic operations, becomes less dominant than surface effects on the nanometer scale, fluidic operation of the femtoliter sampling was designed utilizing surface tension and air pressure control. The working principle of an 11 fL volumetric pipette and a 50 fL flask, which were connected by a nanochannel, was verified. It was found that evaporation of the sample solution by air flow was a significant source of error because of the ultra-small volumes being processed. Thus, the evaporation issue was solved by suppressing the air flow. As a result, the volumetric measurement error was decreased to ±0.06 fL (CV 0.6%), which is sufficiently low for use in nanofluidic analytical applications. This study will present a fundamental technology for the development of novel analytical methods for femtoliter volume samples such as single molecule analyses.
Collapse
Affiliation(s)
- Tatsuro Nakao
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan
| | | | | | | | | | | |
Collapse
|
28
|
Yamamoto K, Morikawa K, Imanaka H, Imamura K, Kitamori T. Picoliter enzyme reactor on a nanofluidic device exceeding the bulk reaction rate. Analyst 2020; 145:5801-5807. [DOI: 10.1039/d0an00998a] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
A picoliter enzyme reactor using a trypsin immobilized nanochannel realized 25 times faster reaction than the bulk reaction.
Collapse
Affiliation(s)
- Koki Yamamoto
- Department of Bioengineering
- School of Engineering
- The University of Tokyo
- Tokyo 113-8656
- Japan
| | - Kyojiro Morikawa
- Department of Applied Chemistry
- School of Engineering
- The University of Tokyo
- Tokyo 113-8656
- Japan
| | - Hiroyuki Imanaka
- Division of Chemistry and Biochemistry
- Graduate School of Natural Science and Technology
- Okayama University
- Okayama 700-8530
- Japan
| | - Koreyoshi Imamura
- Division of Chemistry and Biochemistry
- Graduate School of Natural Science and Technology
- Okayama University
- Okayama 700-8530
- Japan
| | - Takehiko Kitamori
- Department of Bioengineering
- School of Engineering
- The University of Tokyo
- Tokyo 113-8656
- Japan
| |
Collapse
|