1
|
Cheng HP, Yang TH, Wang JC, Chuang HS. Recent Trends and Innovations in Bead-Based Biosensors for Cancer Detection. SENSORS (BASEL, SWITZERLAND) 2024; 24:2904. [PMID: 38733011 PMCID: PMC11086254 DOI: 10.3390/s24092904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024]
Abstract
Demand is strong for sensitive, reliable, and cost-effective diagnostic tools for cancer detection. Accordingly, bead-based biosensors have emerged in recent years as promising diagnostic platforms based on wide-ranging cancer biomarkers owing to the versatility, high sensitivity, and flexibility to perform the multiplexing of beads. This comprehensive review highlights recent trends and innovations in the development of bead-based biosensors for cancer-biomarker detection. We introduce various types of bead-based biosensors such as optical, electrochemical, and magnetic biosensors, along with their respective advantages and limitations. Moreover, the review summarizes the latest advancements, including fabrication techniques, signal-amplification strategies, and integration with microfluidics and nanotechnology. Additionally, the challenges and future perspectives in the field of bead-based biosensors for cancer-biomarker detection are discussed. Understanding these innovations in bead-based biosensors can greatly contribute to improvements in cancer diagnostics, thereby facilitating early detection and personalized treatments.
Collapse
Affiliation(s)
- Hui-Pin Cheng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
| | - Tai-Hua Yang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Department of Orthopedic Surgery, National Cheng Kung University Hospital, Tainan 704, Taiwan
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| | - Jhih-Cheng Wang
- Department of Urology, Chimei Medical Center, Tainan 710, Taiwan
- Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan 710, Taiwan
- School of Medicine, College of Medicine, National Sun Yat-sen University, Kaohsiung 804, Taiwan
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan (T.-H.Y.)
- Medical Device Innovation Center, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
2
|
Hashemi H, Ahmadi H, Rostami Z, Alishahi A, Heidari Z. The role of endothelial growth factor and tear levels in diabetic retinopathy in type 2 diabetes. Int Ophthalmol 2024; 44:143. [PMID: 38498296 DOI: 10.1007/s10792-024-03064-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 02/16/2024] [Indexed: 03/20/2024]
Abstract
PURPOSE To evaluate the tear level of VEGF and the quantity of tear film in type 2 diabetic patients. METHODS Thirty patients with diabetic retinopathy (DR group) and 30 patients with no DR (NDR group), and 30 healthy subjects with age and gender matching were enrolled in this prospective comparative study. The tear samples were collected using the Schirmer strips, and the amount of moisture absorbed by the strips was used to determine the quantitative level of the tear film. The concentration of VEGF in the tear samples was measured using the enzyme-linked immunosorbent assay method. The variables were compared with an independent t-test and covariance analysis. RESULTS Mean tear level of VEGF was significantly higher in DR group (235.42 pg/ml) compared to NDR (75.11 pg/ml) and control (58.77 pg/ml) groups (P ≤ 0.001). There was no significant difference in the mean of VEGF between NDR and control patients (P = 1.00). Mean quantitative tear film levels were 7.15%, 9.72%, and 15.11% in DR, NDR, and healthy subjects, respectively (P < 0.05). The pairwise analysis showed significant differences in the level of VEGF between DR and both NDR (P = 0.001) and normal (P = 0.017) groups. However, there was no significant difference observed between NDR and normal eyes (P = 0.743). CONCLUSION The VEGF level in tear was higher in diabetic patients with DR, independent of tear volume. The tear VEGF measurement can be used as a valuable predictor to prevent DR in diabetic patients.
Collapse
Affiliation(s)
- Hassan Hashemi
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
| | - Hanieh Ahmadi
- Department of Ophthalmology, Faculty of Medicine, Bu-Ali Sina Hospital, Mazandaran University of Medical Sciences, Sari, Iran
| | - Zahra Rostami
- Department of Ophthalmology, Faculty of Medicine, Bu-Ali Sina Hospital, Mazandaran University of Medical Sciences, Sari, Iran
| | - Abbas Alishahi
- Department of Ophthalmology, Faculty of Medicine, Bu-Ali Sina Hospital, Mazandaran University of Medical Sciences, Sari, Iran
- Universal Scientific Education and Research Network (USERN), Tehran, Iran
| | - Zahra Heidari
- Department of Ophthalmology, Faculty of Medicine, Bu-Ali Sina Hospital, Mazandaran University of Medical Sciences, Sari, Iran.
- Psychiatry and Behavioral Sciences Research Center, Mazandaran University of Medical Sciences, Sari, Iran.
| |
Collapse
|
3
|
Guo H, Li J, Lu P. Systematic review and meta-analysis of mass spectrometry proteomics applied to ocular fluids to assess potential biomarkers of age-related macular degeneration. BMC Ophthalmol 2023; 23:507. [PMID: 38087257 PMCID: PMC10717315 DOI: 10.1186/s12886-023-03237-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 11/20/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND Age-related macular degeneration (AMD) is a significant cause of severe vision loss. The main purpose of this study was to identify mass spectrometry proteomics-based potential biomarkers of AMD that contribute to understanding the mechanisms of disease and aiding in early diagnosis. METHODS This study retrieved studies that aim to detect differences relate to proteomics in AMD patients and healthy control groups by mass spectrometry (MS) proteomics approaches. The search process was accord with PRISMA guidelines (PROSPERO database: CRD42023388093). Gene Ontology (GO) analysis and Kyoto Encyclopedia of Genes and Genomes Pathway Analysis (KEGG) were performed on differentially expressed proteins (DEPs) in the included articles using the DAVID database. DEPs were included in a meta-analysis when their effect size could be computed in at least two research studies. The effect size of measured proteins was transformed to the log2-fold change. Protein‒protein interaction (PPI) analysis was conducted on proteins that were statistically significant in the meta-analysis using the String online database. RESULTS Eleven studies fulfilled the inclusion criteria, and 161 DEPs were identified. The GO analysis showed that AMD is significantly related to proteolysis, extracellular exosome and protein binding. In KEGG, the most significant pathway was the complement and coagulation cascades. Meta-analysis results suggested that eight proteins were statistically significant, and according to PPI results, the most significant four proteins were serotransferrin (TF), apolipoprotein A1 (APOA1), complement C3 (C3) and lipocalin-1 (LCN1). CONCLUSIONS Four possible biomarkers, TF, APOA1, C3 and LCN1, were found to be significant in the pathogenesis of AMD and need to be further validated. Further studies should be performed to evaluate diagnostic and therapeutic value of these proteins.
Collapse
Affiliation(s)
- Hanmu Guo
- Department of Ophthalmology, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Jianqing Li
- Department of Ophthalmology, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Peirong Lu
- Department of Ophthalmology, The First Affiliated Hospital of Soochow University, Suzhou, China.
| |
Collapse
|
4
|
Błaszkiewicz M, Walulik A, Florek K, Górecki I, Sławatyniec O, Gomułka K. Advances and Perspectives in Relation to the Molecular Basis of Diabetic Retinopathy-A Review. Biomedicines 2023; 11:2951. [PMID: 38001952 PMCID: PMC10669459 DOI: 10.3390/biomedicines11112951] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 10/26/2023] [Accepted: 10/27/2023] [Indexed: 11/26/2023] Open
Abstract
Diabetes mellitus (DM) is a growing problem nowadays, and diabetic retinopathy (DR) is its predominant complication. Currently, DR diagnosis primarily relies on fundoscopic examination; however, novel biomarkers may facilitate that process and make it widely available. In this current review, we delve into the intricate roles of various factors and mechanisms in DR development, progression, prediction, and their association with therapeutic approaches linked to the underlying pathogenic pathways. Specifically, we focus on advanced glycation end products, vascular endothelial growth factor (VEGF), asymmetric dimethylarginine, endothelin-1, and the epigenetic regulation mediated by microRNAs (miRNAs) in the context of DR.
Collapse
Affiliation(s)
- Michał Błaszkiewicz
- Student Scientific Group of Adult Allergology, Wroclaw Medical University, 50-369 Wroclaw, Poland
| | - Agata Walulik
- Student Scientific Group of Adult Allergology, Wroclaw Medical University, 50-369 Wroclaw, Poland
| | - Kamila Florek
- Student Scientific Group of Adult Allergology, Wroclaw Medical University, 50-369 Wroclaw, Poland
| | - Ignacy Górecki
- Student Scientific Group of Adult Allergology, Wroclaw Medical University, 50-369 Wroclaw, Poland
| | - Olga Sławatyniec
- Student Scientific Group of Adult Allergology, Wroclaw Medical University, 50-369 Wroclaw, Poland
| | - Krzysztof Gomułka
- Clinical Department of Internal Medicine, Pneumology and Allergology, Wroclaw Medical University, 50-369 Wroclaw, Poland
| |
Collapse
|
5
|
Chen LY, Hsu SM, Wang JC, Yang TH, Chuang HS. Photonic crystal enhanced immunofluorescence biosensor integrated with a lateral flow microchip: Toward rapid tear-based diabetic retinopathy screening. BIOMICROFLUIDICS 2023; 17:044102. [PMID: 37484814 PMCID: PMC10361775 DOI: 10.1063/5.0158780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 07/10/2023] [Indexed: 07/25/2023]
Abstract
Diabetic retinopathy (DR) has accounted for major loss of vision in chronic diabetes. Although clinical statistics have shown that early screening can procrastinate or improve the deterioration of the disease, the screening rate remains low worldwide because of the great inconvenience of conventional ophthalmoscopic examination. Instead, tear fluid that contains rich proteins caused by direct contact with eyeballs is an ideal substitute to monitor vision health. Herein, an immunofluorescence biosensor enhanced by a photonic crystal (PhC) is presented to handle the trace proteins suspended in the tear fluid. The PhC was constructed by self-assembled nanoparticles with a thin layer of gold coated on top of it. Then, the PC substrate was conjugated with antibodies and placed in a microchannel. When the capillary-driven tear sample flew over the PC substrate, the immunoassay enabled the formation of a sandwich antibody-antigen-antibody configuration for PhC-enhanced immunofluorescence. The use of PhC resulted in a concentration enhancement of more than tenfold compared to non-PhC, while achieving an equivalent signal intensity. The limit of detection for the target biomarker, lipocalin-1 (LCN-1), reached nearly 3 μg/ml, and the turnaround time of each detection was 15 min. Finally, a preclinical evaluation was conducted using ten tear samples. A clear trend was observed, showing that the concentrations of LCN-1 were at least twofold higher in individuals with chronic diabetes or DR than in healthy individuals. This trend was consistent with their medical conditions. The results provided a direct proof-of-concept for the proposed PhC biosensor in rapid tear-based DR screening.
Collapse
Affiliation(s)
- Li-Ying Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Sheng-Min Hsu
- Department of Ophthalmology, National Cheng Kung University Hospital, Tainan 701, Taiwan
| | | | | | | |
Collapse
|
6
|
Winiarczyk M, Biela K, Michalak K, Winiarczyk D, Mackiewicz J. Changes in Tear Proteomic Profile in Ocular Diseases. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:13341. [PMID: 36293921 PMCID: PMC9603516 DOI: 10.3390/ijerph192013341] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 10/10/2022] [Accepted: 10/13/2022] [Indexed: 06/16/2023]
Abstract
The search for proteomic biomarkers in ocular disease is one of the most important research directions in recent years. Reliable biomarkers can be an immense adjuvant for both diagnostic and therapeutic approaches. There is no more readily available ocular tissue for proteomic analysis than tear film, which makes an interesting target for the biomarker search. Tear film is a complex fluid consisting of a superficial lipid layer, which covers the aqueous-mucous layer. Its complexity makes it a perfect candidate for all the "omics" approaches. Glaucoma, cataract, age-related macular degeneration, and other diseases are commonly thought to have a multifactorial background. Currently, no reliable non-invasive tests are available that would help physicians with screening and further patient management. The aim of the study is to present modern methods of measuring biomarkers in tears, with particular emphasis on spectrometric methods, and to discuss their diagnostic and therapeutic usefulness.
Collapse
Affiliation(s)
- Mateusz Winiarczyk
- Department of Vitreoretinal Surgery, Medical University of Lublin, 20-059 Lublin, Poland
| | - Katarzyna Biela
- Department of Vitreoretinal Surgery, Medical University of Lublin, 20-059 Lublin, Poland
- Department of Ophthalmology, Provincial Hospital of Zamosc, 22-400 Zamosc, Poland
| | - Katarzyna Michalak
- Department of Epizootiology, University of Life Sciences of Lublin, 20-400 Lublin, Poland
| | - Dagmara Winiarczyk
- Department of Internal Diseases of Small Animals, University of Life Sciences of Lublin, 20-400 Lublin, Poland
| | - Jerzy Mackiewicz
- Department of Vitreoretinal Surgery, Medical University of Lublin, 20-059 Lublin, Poland
| |
Collapse
|
7
|
Ozdalgic B, Gul M, Uygun ZO, Atçeken N, Tasoglu S. Emerging Applications of Electrochemical Impedance Spectroscopy in Tear Film Analysis. BIOSENSORS 2022; 12:827. [PMID: 36290964 PMCID: PMC9599721 DOI: 10.3390/bios12100827] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 09/20/2022] [Accepted: 09/24/2022] [Indexed: 06/16/2023]
Abstract
Human tear film, with a flow rate of 1-3 µL/min, is a rich bodily fluid that transmits a variety of metabolites and hormones containing proteins, lipids and electrolytes that provide clues about ocular and systemic diseases. Analysis of disease biomarkers such as proteins, mRNA, enzymes and cytokines in the tear film, collected by noninvasive methods, can provide significant results for sustaining a predictive, preventive and personalized medicine regarding various diseases such as glaucoma, diabetic retinopathy, keratoconus, dry eye, cancer, Alzheimer's disease, Parkinson's disease and COVID-19. Electrochemical impedance spectroscopy (EIS) offers a powerful technique for analyzing these biomarkers. EIS detects electrical equivalent circuit parameters related to biorecognition of receptor-analyte interactions on the electrode surface. This method is advantageous as it performs a label-free detection and allows the detection of non-electroactive compounds that cannot be detected by direct electron transfer, such as hormones and some proteins. Here, we review the opportunities regarding the integration of EIS into tear fluid sampling approaches.
Collapse
Affiliation(s)
- Berin Ozdalgic
- Department of Mechanical Engineering, Engineering Faculty, Koç University, Istanbul 34450, Türkiye
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul 34450, Türkiye
- Division of Optometry, School of Med Services & Techniques, Dogus University, Istanbul 34775, Türkiye
| | - Munire Gul
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul 34450, Türkiye
| | - Zihni Onur Uygun
- Department of Mechanical Engineering, Engineering Faculty, Koç University, Istanbul 34450, Türkiye
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul 34450, Türkiye
- Department of Biochemistry, Faculty of Medicine, Kafkas University, Kars 36100, Türkiye
| | - Nazente Atçeken
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul 34450, Türkiye
| | - Savas Tasoglu
- Department of Mechanical Engineering, Engineering Faculty, Koç University, Istanbul 34450, Türkiye
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul 34450, Türkiye
- Boğaziçi Institute of Biomedical Engineering, Boğaziçi University, Istanbul 34684, Türkiye
- Koç University Arçelik Research Center for Creative Industries (KUAR), Koç University, Istanbul 34450, Türkiye
| |
Collapse
|
8
|
Vieira M, Fernandes R, Ambrósio AF, Cardoso V, Carvalho M, Weng Kung P, Neves MAD, Mendes Pinto I. Lab-on-a-chip technologies for minimally invasive molecular sensing of diabetic retinopathy. LAB ON A CHIP 2022; 22:1876-1889. [PMID: 35485913 DOI: 10.1039/d1lc01138c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Diabetic retinopathy (DR) is the most common diabetic eye disease and the worldwide leading cause of vision loss in working-age adults. It progresses from mild to severe non-proliferative or proliferative DR based on several pathological features including the magnitude of blood-retinal barrier breakdown and neovascularization. Available pharmacological and retinal laser photocoagulation interventions are mostly applied in the advanced stages of DR and are inefficient in halting disease progression in a significantly high percentage of patients. Yet, recent evidence has shown that some therapies could potentially limit DR progression if applied at early stages, highlighting the importance of early disease diagnostics. In the past few decades, different imaging modalities have proved their utility for examining retinal and optic nerve changes in patients with retinal diseases. However, imaging based-methodologies solely rely on morphological examination of the retinal vascularization and are not suitable for recurrent and personalized patient evaluation. This raises the need for new technologies to enable accurate and early diagnosis of DR. In this review, we critically discuss the potential clinical benefit of minimally-invasive molecular biomarker identification and profiling of diabetic patients who are at risk of developing DR. We provide a comparative overview of conventional and recently developed lab-on-a-chip technologies for quantitative assessment of potential DR molecular biomarkers and discuss their advantages, current limitations and challenges for future practical implementation and continuous patient monitoring at the point-of-care.
Collapse
Affiliation(s)
- Maria Vieira
- International Iberian Nanotechnology Laboratory (INL), Braga, Portugal
| | - Rosa Fernandes
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Faculty of Medicine, University of Coimbra, Coimbra, Portugal
- Center for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
- Association for Innovation and Biomedical Research on Light and Image, Coimbra, Portugal
| | - António F Ambrósio
- Coimbra Institute for Clinical and Biomedical Research (iCBR), Faculty of Medicine, University of Coimbra, Coimbra, Portugal
- Center for Innovative Biomedicine and Biotechnology (CIBB), University of Coimbra, Portugal
- Clinical Academic Center of Coimbra (CACC), Coimbra, Portugal
- Association for Innovation and Biomedical Research on Light and Image, Coimbra, Portugal
| | - Vanessa Cardoso
- CMEMS-UMinho, University of Minho, Campus of Azurém, Guimarães, Portugal
- LABBELS - Associate Laboratory, Guimarães, Braga, Portugal
| | - Mariana Carvalho
- International Iberian Nanotechnology Laboratory (INL), Braga, Portugal
| | - Peng Weng Kung
- Spin Dynamics in Health Engineering Group, Songshan Lake Materials Laboratory, Dongguan, China
| | | | - Inês Mendes Pinto
- International Iberian Nanotechnology Laboratory (INL), Braga, Portugal
- Institute for Research and Innovation in Health (i3S), Porto, Portugal.
| |
Collapse
|
9
|
Microfluidic free-flow electrophoresis: a promising tool for protein purification and analysis in proteomics. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.02.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
10
|
Nandi SK, Singh D, Upadhay J, Gupta N, Dhiman N, Mittal SK, Mahindroo N. Identification of tear-based protein and non-protein biomarkers: Its application in diagnosis of human diseases using biosensors. Int J Biol Macromol 2021; 193:838-846. [PMID: 34728300 DOI: 10.1016/j.ijbiomac.2021.10.198] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 09/30/2021] [Accepted: 10/26/2021] [Indexed: 12/27/2022]
Abstract
Discovery of robust, selective and specific biomarkers are important for early diagnosis and monitor progression of human diseases. Eye being a common target for several human diseases, vision impediment and complications are often associated with systemic and ocular diseases. Tears are bodily fluids that are closest to eye and are rich in protein content and other metabolites. As a biomarker repository, it advantages over other bodily fluids due to the ability to collect it non-invasively. In this review, we highlight some recent advancements in identification of tear-based protein biomarkers like lacryglobin and cystatin SA for cancer; interleukin-6 and immunoglobulin-A antibody for COVID-19; tau, amyloid-β-42 and lysozyme-C for Alzheimer's disease; peroxiredoxin-6 and α-synuclein for Parkinson's disease; kallikrein, angiotensin converting enzyme and lipocalin-1 for glaucoma; lactotransferrin and lipophilin-A for diabetic retinopathy and zinc-alpha-2 glycoprotein-1, prolactin and calcium binding protein-A4 for eye thyroid disease. We also discussed identification of tear based non-protein biomarkers like lysophospholipids and acetylcarnitine for glaucoma, 8-hydroxy-2'-deoxyquanosine and malondialdehyde for thyroid eye disease. We elucidate technological advancement in developing tear-based biosensors for diagnosis and monitoring diseases such as diabetes, diabetic retinopathy and Alzheimer's disease. Altogether, the study of tears as potential biomarkers for early diagnosis of human diseases is promising.
Collapse
Affiliation(s)
- Sandip K Nandi
- School of Health Sciences, University of Petroleum and Energy Studies, Dehradun, Uttarakhand 248007, India.
| | - Deepanmol Singh
- School of Health Sciences, University of Petroleum and Energy Studies, Dehradun, Uttarakhand 248007, India
| | - Jyoti Upadhay
- School of Health Sciences, University of Petroleum and Energy Studies, Dehradun, Uttarakhand 248007, India
| | - Neeti Gupta
- Department of Ophthalmology, All India Institute of Medical Sciences, Rishikesh 249203, India
| | - Nayan Dhiman
- School of Health Sciences, University of Petroleum and Energy Studies, Dehradun, Uttarakhand 248007, India
| | - Sanjeev Kumar Mittal
- Department of Ophthalmology, All India Institute of Medical Sciences, Rishikesh 249203, India
| | - Neeraj Mahindroo
- School of Health Sciences, University of Petroleum and Energy Studies, Dehradun, Uttarakhand 248007, India.
| |
Collapse
|
11
|
Zheng X, Gao S, Wu J, Hu X. A Fluorescent Aptasensor Based on Assembled G-Quadruplex and Thioflavin T for the Detection of Biomarker VEGF165. Front Bioeng Biotechnol 2021; 9:764123. [PMID: 34869275 PMCID: PMC8636943 DOI: 10.3389/fbioe.2021.764123] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 10/29/2021] [Indexed: 01/05/2023] Open
Abstract
VEGF165, a regulator of angiogenesis, has been widely used as a serum biomarker for a number of human diseases, including cancer, rheumatoid arthritis, bronchial asthma, and diabetic eye disease. The rapid, accurate, and convenient detection of VEGF165 is a crucial step in effective healthcare monitoring, disease diagnosis, and prognosis assessment. In this study, a fluorescent aptasensor based on an assembled G-quadruplex and the signal molecule ThT was developed for VEGF165 detection. First, G-rich DNA fragments were assembled at both ends of the anti-VEGF165 aptamer, and the B-DNA form was converted into a G-quadruplex structure aptamer (G4-Apt). Then, ThT was introduced, and the G-quadruplex significantly enhanced the fluorescence intensity of the bound ThT. When VEGF165 was present, the higher affinity of the aptamer to the target protein allowed the G4-Apt/VEGF165 complex to form and release ThT, which emitted only weak fluorescence in the free state. Therefore, the aptasensor exhibited a good linear detection window from 1.56 to 25 nM VEGF165, with a limit of detection of 0.138 nM. In addition, the aptasensor was applied to detect VEGF165 in clinical serum samples, showing good accuracy, reproducibility, and stability. These results indicate that our developed fluorescent aptasensor can potentially be a reliable, convenient, and cost-effective approach for the sensitive, specific, and rapid detection of the VEGF165 biomarker.
Collapse
Affiliation(s)
- Xin Zheng
- Department of Clinical Laboratory, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Shunxiang Gao
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Institutes of Brain Science, State Key Laboratory of Medical Neurobiology and MOE Frontiers Center for Brain Science, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Jihong Wu
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Institutes of Brain Science, State Key Laboratory of Medical Neurobiology and MOE Frontiers Center for Brain Science, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia, Fudan University, Shanghai, China
- Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Xiaobo Hu
- Department of Clinical Laboratory, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| |
Collapse
|
12
|
Chen WL, Jayan M, Kwon JS, Chuang HS. Facile open-well immunofluorescence enhancement with coplanar-electrodes-enabled optoelectrokinetics and magnetic particles. Biosens Bioelectron 2021; 193:113527. [PMID: 34325238 DOI: 10.1016/j.bios.2021.113527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 07/05/2021] [Accepted: 07/19/2021] [Indexed: 11/29/2022]
Abstract
Electrokinetic manipulation has been proven powerful in enhancing the sensing capability of general-purpose biochips. However, the close-form configuration of biochips and the required use of low electric conductivity limit their practicability. In this study, an open-well microfluidic system facilitated with coplanar-electrodes-enabled optoelectrokinetic concentration and magnetic particles were therefore developed to overcome these challenges. The open side achieves optoelectrokinetic manipulation for biosignal enhancement, enabling free manual operations. Magnetic particles were employed in immunoassays to facilitate the rapid onsite separation of targets. A common cytokine biomarker found in many diseases, that is, tumor necrosis factor alpha (TNF-α), was used for assessing the immunosensing system. In addition to the benefits inherited from the immunoassays, the fluorescent signal enhanced by the optoelectrokinetic technique also featured rapid enhancement in 1 min and a limit of detection of as low as 2.9 pg/mL. The open-well architecture allowed the entire immunosensing process to be completed on site without frequent off-site washing. For a practical test, the TNF-α in human tear fluids was measured by the developed device and validated with a standard enzyme-linked immunosorbent assay (ELISA). The data show consistency in terms of trend. The developed open-well optoelectrokinetic device provides an insight into future facile clinical diagnoses. By simply modifying the surface linkers on the magnetic particles, the technique can be further extended to more other trace biomarker detections.
Collapse
Affiliation(s)
- Wei-Long Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, 701, Taiwan.
| | - Mansha Jayan
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, 701, Taiwan
| | - Jae-Sung Kwon
- Department of Mechanical Engineering, Incheon National University, Incheon, Republic of Korea.
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, 701, Taiwan; Core Facility Center, National Cheng Kung University, Tainan, 701, Taiwan; Medical Device Innovation Center, National Cheng Kung University, Tainan, 701, Taiwan.
| |
Collapse
|
13
|
Chen X, Ning Y, Pan S, Liu B, Chang Y, Pang W, Duan X. Mixing during Trapping Enabled a Continuous-Flow Microfluidic Smartphone Immunoassay Using Acoustic Streaming. ACS Sens 2021; 6:2386-2394. [PMID: 34102847 DOI: 10.1021/acssensors.1c00602] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Smartphone-enabled microfluidic chemiluminescence immunoassay is a promising portable system for point-of-care (POC) biosensing applications. However, due to the rather faint emitted light in such a limited sample volume, it is still difficult to reach the clinically accepted range when the smartphone serves as a standalone detector. Besides, the multiple separation and washing steps during sample preparation hinder the immunoassay's applications for POC usage. Herein, we proposed a novel acoustic streaming tweezers-enabled microfluidic immunoassay, where the probe particles' purification, reaction, and sensing were simply achieved on the same chip at continuous-flow conditions. The dedicatedly designed high-speed microscale vortexes not only enable dynamic trapping and washing of the probe particles on-demand but also enhance the capture efficiency of the heterogeneous particle-based immunoassay through active mixing during trapping. The enriched probe particles and enhanced biomarker capture capability increase the local chemiluminescent light intensity and enable direct capture of the immunobinding signal by a regular smartphone camera. The system was tested for prostate-specific antigen (PSA) sensing both in buffer and serum, where a limit of detection of 0.2 ng/mL and a large dynamic response range from 0.3 to 10 ng/mL using only 10 μL of sample were achieved in a total assay time of less than 15 min. With the advantages of on-chip integration of sample preparation and detection and high sensing performance, the developed POC platform could be applied for many on-site diagnosis applications.
Collapse
Affiliation(s)
- Xian Chen
- State Key Laboratory of Precision Measuring Technology & Instruments and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Yuan Ning
- State Key Laboratory of Precision Measuring Technology & Instruments and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Shuting Pan
- State Key Laboratory of Precision Measuring Technology & Instruments and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Bohua Liu
- State Key Laboratory of Precision Measuring Technology & Instruments and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Ye Chang
- State Key Laboratory of Precision Measuring Technology & Instruments and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Wei Pang
- State Key Laboratory of Precision Measuring Technology & Instruments and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology & Instruments and College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| |
Collapse
|
14
|
Wan WC, Long Y, Wan WW, Liu HZ, Zhang HH, Zhu W. Plasma melatonin levels in patients with diabetic retinopathy secondary to type 2 diabetes. World J Diabetes 2021; 12:138-148. [PMID: 33594333 PMCID: PMC7839166 DOI: 10.4239/wjd.v12.i2.138] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 11/26/2020] [Accepted: 12/10/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Melatonin is reported to be related to diabetes mellitus (DM) risk; however, the effect of melatonin on diabetic retinopathy (DR) risk remains unclear.
AIM The aim of this study was to determine the effect of melatonin on DR risk.
METHODS A hospital-based case-control study was conducted from January 2020 to June 2020. DR was assessed using the Diabetic Retinopathy preferred practice pattern (PPP)-updated 2019 criteria. The participants were divided into the DM cases without DR (NDR) group, non-proliferative DR (NPDR) group and proliferative DR (PDR) group. Plasma melatonin concentration was detected with the enzyme-linked immunosorbent assay kit. The relationship between plasma melatonin concentration and DR risk as well as severity was assessed.
RESULTS It was found that plasma melatonin was 72.83 ± 16.25, 60.38 ± 13.43, 44.48 ± 10.30 and 44.69 ± 8.95 pg/mL in healthy controls, NDR group, NPDR and PDR group, respectively. In addition, it was found that plasma melatonin could be used as a potential diagnostic biomarker for DR (AUC = 0.893, P < 0.001). There was a significant positive relationship between total bilirubin and melatonin content (P < 0.001) based on the correlation assay. Significant associations between total bilirubin and melatonin content were also detected in the NPDR (R2 = 0.360, P < 0.001) and PDR (R2 = 0.183, P < 0.001) groups.
CONCLUSION The data obtained in this study demonstrated that plasma melatonin concen-tration was decreased in DR cases and could be used as a sensitive and specific marker for the diagnosis of DR. A significant positive relationship between total bilirubin and melatonin was detected. More related studies are required to understand the role of melatonin in DR.
Collapse
Affiliation(s)
- Wen-Cui Wan
- Department of Ophthalmology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
| | - Yang Long
- Department of Ophthalmology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
| | - Wei-Wei Wan
- Department of Ophthalmology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
| | - Hong-Zhuo Liu
- Department of Ophthalmology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
| | - Hao-Hao Zhang
- Department of Endocrinology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
| | - Wei Zhu
- Department of Ophthalmology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan Province, China
- Department of Ophthalmology, Changshu No. 2 People's Hospital, Changshu 215000, Jiangsu Province, China
| |
Collapse
|
15
|
Colorimetric Diagnostic Capillary Enabled by Size Sieving in a Porous Hydrogel. BIOSENSORS-BASEL 2020; 10:bios10100130. [PMID: 32977557 PMCID: PMC7598291 DOI: 10.3390/bios10100130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 09/20/2020] [Accepted: 09/21/2020] [Indexed: 01/06/2023]
Abstract
Handy and disposable point-of-care diagnostics facilitate the early screening of severe diseases in resource-limited areas. To address urgent needs in inconvenient sites, a simple colorimetric diagnostic device equipped with a capillary tube with porous hydrogel and immunocomplex particles was developed for the rapid detection of biomarkers (16 min). In this device, probe particles attach to capture particles (dp = 40 µm) and form sandwiched immunocomplexes in the presence of target biomarkers, and a red color progressively emerges when the sandwiched immunocomplex particles are blocked by the porous hydrogel embedded inside the glass capillary. Colorimetric aggregation was recorded using a smartphone and analyzed with imaging software. The limit of detection reached 1 ng/mL and showed a maximum of 79% accuracy compared with that obtained through a conventional spectrophotometric technique. The level of a diabetic retinopathy (DR) biomarker, lipocalin-1 (LCN-1), was measured in 1 µL of a human tear sample and used in testing the practicability of the proposed device. All healthy subjects showed lower intensity levels than the other diabetic counterparts (proliferative DR or nonproliferative DR patients), implying the potential of this device in clinical applications. Overall, the diagnostic device facilitates point-of-care-testing and provides a low-cost (~1 USD), compact, and reliable tool for early diagnosis in resource-limited areas.
Collapse
|