1
|
Rahimpoor R, Soleymani-Ghoozhdi D, Firoozichahak A, Alizadeh S. Needle trap device technique: From fabrication to sampling. Talanta 2024; 276:126255. [PMID: 38776771 DOI: 10.1016/j.talanta.2024.126255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 03/17/2024] [Accepted: 05/11/2024] [Indexed: 05/25/2024]
Abstract
Needle Trap Device (NTD) as a novel, versatile, and eco-friendly technique has played an important role in analytical and environmental chemistry. The distinctive role of this interdisciplinary technique can be defended through the sampling and analysis of biological samples and industrial pollutants in gaseous and liquid environments. In recent years, significant efforts have been made to enhance the performance of the needle trap device resulting in the development of novel extraction routes by various packing materials with improved selectivity and enhanced adsorption characteristics. These achievements can lead to the facilitated pre-concentration of desired analytes. This review tries to have a comparative and comprehensive survey of the three important areas of NTD technique: I) Fabrication and preparation procedures of NTDs; II) Sampling techniques of pollutants using NTDs; and III) Employed materials as adsorbents in NTDs. In the packing-material section, the commercial and synthetic adsorbents such as carbon materials, metal-organic frameworks, aerogel, and polymers are considered. Furthermore, the limitations and potential areas for future development of the NTD technique are presented.
Collapse
Affiliation(s)
- Razzagh Rahimpoor
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences, Larestan, Iran
| | | | - Ali Firoozichahak
- Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science, Gonabad, Iran.
| | - Saber Alizadeh
- Department of Chemistry, Bu-Ali-Sina University, Hamedan, Iran
| |
Collapse
|
2
|
Maleki S, Hashemi P, Adeli M. A simple and portable vacuum assisted headspace solid phase microextraction device coupled to gas chromatography based on covalent organic framework/metal organic framework hybrid for simultaneous analysis of volatile and semi-volatile compounds in soil. J Chromatogr A 2023; 1705:464195. [PMID: 37423076 DOI: 10.1016/j.chroma.2023.464195] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 07/02/2023] [Accepted: 07/03/2023] [Indexed: 07/11/2023]
Abstract
Various microextraction methods have demonstrated a positive effect when assisted by vacuum. However, working with such systems is often laborious, they often require expensive and non-portable vacuum pumps, and may even suck off some sample vapor or solid particles during the evacuation process. To address these issues, a simple, and affordable vacuum-assisted headspace solid-phase microextraction (HS-SPME) device was developed in this study. The device, named In Syringe Vacuum-assisted HS-SPME (ISV-HS-SPME), utilizes an adjustable 40 mL glass syringe as a vacuum provider and sampling vessel. A new fiber coating, made from a hybrid of covalent triazine-based frameworks and metal-organic frameworks (COF/MOF), was prepared and characterized by Fourier transform infrared spectrometry, field emission scanning electron microscopy, energy dispersive X-ray, X-ray diffraction, thermogravimetric analysis, and Brunauer-Emmett-Teller techniques for use in the ISV-HS-SPME. By optimizing parameters such as extraction temperature, extraction time, desorption temperature, desorption time, and, humidity using a simplex method, the ISV system was found to increase the extraction efficiency of polycyclic aromatic hydrocarbons (PAHs) and benzene, toluene, ethylbenzene, and xylenes (BTEX) in solid samples by up to 175%. The determinations were followed by GC-FID measurements. Compared to three commercially available fibers, the ISV-HS-SPME device with the COF/MOF (2DTP/MIL-101-Cr) fiber exhibited significantly higher peak areas for PAHs and BTEX. The linear dynamic ranges for BTEX and PAHs were 7.1-9000 ng g-1 and 0.23-9000 ng g-1, respectively, with limits of detection ranging from 2.1-5 ng g-1 for BTEX and 0.07-1.6 ng g-1 for PAHs. The relative standard deviation of the method was 2.6-7.8% for BTEX and 1.6-6.7% for PAHs. The ISV-HS-SPME was successfully used to simultaneously determine PAHs and BTEX in polluted soil samples with recoveries ranging from 80.4 to 108%.
Collapse
Affiliation(s)
- Sara Maleki
- Department of analytical chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Payman Hashemi
- Department of analytical chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran.
| | - Mohsen Adeli
- Department of analytical chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| |
Collapse
|
3
|
Urinary bio-monitoring of aromatic amine derivatives by new needle trap device packed with the multi-component adsorbent. Sci Rep 2023; 13:4243. [PMID: 36918633 PMCID: PMC10014860 DOI: 10.1038/s41598-023-31108-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 03/06/2023] [Indexed: 03/16/2023] Open
Abstract
Aromatic amines are a large group of chemical compounds that have attracted the attention of researchers due to their toxicity and carcinogenicity. This study aimed to develop an efficient method for sampling and analysis of aromatic amines (Aniline, N, N-dimethylaniline, 2-chloroaniline, and 3-chloroaniline) from the vapour phase (headspace) of urine samples. For the implementation of this plan, a needle trap device packed with the three-component adsorbent consisting of nano-Hydroxy Apatite (nHA), Zeolite (Ze), and Metal-Organic Framework (MOF) equipped with GC-FID was employed for the first phase. Examination of the prepared adsorbents was performed by FT-IR, PXRD, and FE-SEM techniques. The optimal value of considerable parameters such as time and temperature of extraction, salt content, and pH were established using the Response Surface Methodology-Central Composite Design (RMS-CCD) method. In this way, the optimal extraction of targeted analytes was accomplished in 41 min at 41 °C with NaCl content of 33.0% (w/v) and pH: 13.0, respectively. Also, the repeatability and reproducibility of the method were calculated to be in the range of 2.2-7.1% and 3.9-8.1%, respectively, which indicates the acceptable precision of the method. Also, the limit of detection (LOD) and limit of quantification (LOQ) were determined in the range of 0.3-32.0 ng.L-1 and 0.8-350.0 ng.L-1, respectively, which proves the high sensitivity of the proposed method. Furthermore, the recovery percent of the extracted analytes was concluded in the range of 97.0-99.0% after 6 and 30 days of the sampling and storage at 25 °C and 4 °C, respectively. Finally, the designed procedure was employed in the analysis of the above-mentioned aromatic amines in the real urine samples. The achieved results illustrate that the three-component absorbent system (nHA;Ze;MOF@NTD) can be introduced as an efficient, fast-response, sensitive, and versatile procedure for trace analysis of the different aromatic amine compounds in public and occupational health.
Collapse
|
4
|
Needle-trap device packed with the MIL-100(Fe) metal–organic framework for the extraction of the airborne organochlorine pesticides. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106866] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
5
|
Naseri N, Kharrazi S, Abdi K, Alizadeh R. Fabrication of an SPME fiber based on ZnO@GA nanorods coated onto fused silica as a highly efficient absorbent for the analysis of cancer VOCs in water and urine. Anal Chim Acta 2021; 1183:338983. [PMID: 34627504 DOI: 10.1016/j.aca.2021.338983] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 08/09/2021] [Accepted: 08/22/2021] [Indexed: 01/26/2023]
Abstract
Analysis of volatile organic compounds (VOCs) secreted in urine, blood, breath, etc. is a new method for monitoring the metabolism and biochemistry of the human body. However, due to the complexity of samples, a pre-concentration step is necessary before the final analysis with gas chromatography-mass spectroscopy (GC-MS). Therefore, miniaturized extraction methods such as solid-phase microextraction (SPME) can be a promising and simple pre-concentration technique. Different strategies have been adopted for the fabrication or modification of SPME fibers. This study presents the preparation and characterization of glass optical fibers coated with ZnO nanorods functionalized with gallic acid (ZnO@GA nanorod) as SPME adsorbent in GC-MS. ZnO@GA nanorods were synthesized separately and then coated onto the fibers. The coated fibers were characterized by using field emission scanning electron microscopy coupled with energy dispersive analysis of X-rays (FESEM/EDAX) and Fourier transform infrared spectroscopy (FTIR) techniques. Possessing a high surface to volume ratio of ZnO nanorods and functional groups of GA, the ZnO@GA nanorod-based SPME fibers exhibited good extraction performance for VOCs comparing with the commercial polydimethylsiloxane (PDMS) coated fibers. Under optimal conditions (NaCl concentration, 30% w/v; extraction time of 25 min; pH, 5-7 and stirring rate of 400 rpm) ZnO@GA nanorods coated fibers achieved low detection limits (0.32-4.8 μg/L), low quantification limits (1.8-16.3 μg/L) and good linearity (5-1000 μg/L) for selected VOCs. The repeatability (n = 3) for a single fiber was within the range of 4.1-7.9% (intra-day) and 5.7-9.6% (inter-day) while the reproducibility (n = 3) of fiber-to-fiber were in the range of 4.7% and 9.9%. This method was successfully used for the determination of six VOCs in water and urine with satisfactory recoveries of 90-112%. ZnO@GA nanorod coated fibers, despite possessing a much thinner coating compared to the commercial fibers, revealed a better overall extraction efficiency towards VOCs. These results indicated that the ZnO@GA provided a promising alternative in sample pretreatment and analysis in GC-MS.
Collapse
Affiliation(s)
- Neda Naseri
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine (SATiM), Tehran University of Medical Sciences (TUMS), Tehran, Iran
| | - Sharmin Kharrazi
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine (SATiM), Tehran University of Medical Sciences (TUMS), Tehran, Iran.
| | - Khosrou Abdi
- Iranian National Center for Addiction Studies (INCAS), Tehran University of Medical Sciences, Tehran, Iran.
| | - Reza Alizadeh
- Department of Chemistry, Faculty of Science, Qom University, Qom, Iran
| |
Collapse
|
6
|
Salehpour N, Bayatloo MR, Nojavan S. Magnetic solid-phase extraction of high molecular weight peptides using stearic acid-functionalized magnetic hydroxyapatite nanocomposite: determination of some hypothalamic agents in biological samples. Anal Bioanal Chem 2021; 413:7609-7623. [PMID: 34668043 DOI: 10.1007/s00216-021-03725-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 10/05/2021] [Accepted: 10/07/2021] [Indexed: 10/20/2022]
Abstract
Therapeutic peptides have an important effect on physiological function and human health, so it is momentous to quantify and detect low levels of these biomolecules in biological samples for treatment and diagnostic purposes. In the present study, an efficient magnetic solid-phase extraction (MSPE) method was developed based on stearic acid-functionalized magnetic hydroxyapatite nanocomposite (MHAP/SA) as a novel and cost-effective adsorbent for extraction of five hypothalamic-related peptides (goserelin, octreotide, triptorelin, somatostatin, and cetrorelix) from biological samples. To characterize the morphology and physicochemical properties of MHAP/SA, Fourier transform infrared spectroscopy (FT-IR), energy-dispersive X-ray spectroscopy (EDS), field emission scanning microscopy (FE-SEM), CHNS elemental analysis, Brunauer-Emmett-Teller (BET), and vibrating sample magnetometry (VSM) were applied. Under optimum conditions, the proposed method (MSPE-HPLC-UV) represented favorable linearity with R2 ≥ 0.9987, suitable intra- and inter-day precisions (RSD ≤ 6.9% and RSD ≤ 8.1%, respectively, n = 3), and limits of detection and quantification in the range of 0.75-1.12 ng mL-1 and 2.50-3.75 ng mL-1, respectively. Eventually, the proposed method was used for the extraction and quantification of target therapeutic peptides in plasma and urine samples, and satisfactory relative recoveries were achieved in the range of 90.6-110.3%.
Collapse
Affiliation(s)
- Niloofar Salehpour
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, G. C., Evin, 1983969411, Tehran, Iran
| | - Mohammad Reza Bayatloo
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, G. C., Evin, 1983969411, Tehran, Iran
| | - Saeed Nojavan
- Department of Analytical Chemistry and Pollutants, Shahid Beheshti University, G. C., Evin, 1983969411, Tehran, Iran.
| |
Collapse
|
7
|
Vakh C, Malkova K, Syukkalova E, Bobrysheva N, Voznesenskiy M, Bulatov A, Osmolovskaya O. Chemical and computational strategy for design of "switchable" sorbent based on hydroxyapatite nanoparticles for dispersive micro-solid phase extraction of tetracyclines. JOURNAL OF HAZARDOUS MATERIALS 2021; 419:126504. [PMID: 34323728 DOI: 10.1016/j.jhazmat.2021.126504] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 06/19/2021] [Accepted: 06/23/2021] [Indexed: 06/13/2023]
Abstract
A challenging task in analytical chemistry is an application of renewable and natural materials for isolation of hazardous substances such as antimicrobial drugs from environmental samples. The energy-efficient scalable hydrothermal procedure to fabricate the eco-friendly "switchable" sorbent based on hydroxyapatite nanoparticles with in situ modified surface using a small amount of capping agents was developed. Sorbents characterization including the surface composition investigation via quantum-chemical calculation based on the original approach was provided. The sorbents demonstrated well expressed controllable surface switching and high values of the sorption and elution efficiency for tetracycline, oxytetracycline, and chlortetracycline achieved by simple change of the medium pH. These processes were thoroughly discussed based on the results of chemical and computational experiments. A simple and universal strategy for choosing a suitable sorbent for solid phase extraction of target analytes was proposed for the first time. It was shown that the developed eco-friendly sample preparation procedure with use of biocompatible sorbents could be applied both for removal of target analytes from sample matrix (water samples) as well as for the quantitative analytes determination after elution step. It is believed that the presented research is significant for the determination of different amphoteric analytes in wide variety of samples.
Collapse
Affiliation(s)
- Christina Vakh
- Institute of Chemistry, St. Petersburg State University, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia.
| | - Ksenia Malkova
- Institute of Chemistry, St. Petersburg State University, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Evgeniya Syukkalova
- Institute of Chemistry, St. Petersburg State University, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Natalia Bobrysheva
- Institute of Chemistry, St. Petersburg State University, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Mikhail Voznesenskiy
- Institute of Chemistry, St. Petersburg State University, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Andrey Bulatov
- Institute of Chemistry, St. Petersburg State University, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| | - Olga Osmolovskaya
- Institute of Chemistry, St. Petersburg State University, SPbU, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia
| |
Collapse
|
8
|
Souri Z, Alizadeh S, Nematollahi D, Mazloum-Ardakani M, Karami A. A green and template-free electropolymerization of imipramine. The decoration of sponge-like polymer film with gold nanoparticles. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115340] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
9
|
Bio-monitoring of non-metabolized BTEX compounds in urine by dynamic headspace-needle trap device packed with 3D Ni/Co-BTC bimetallic metal-organic framework as an efficient absorbent. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106229] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
10
|
Rahimpoor R, Firoozichahak A, Nematollahi D, Alizadeh S, Alizadeh PM, Alinaghi Langari AA. Determination of halogenated hydrocarbons in urine samples using a needle trap device packed with Ni/Zn-BTC bi-MMOF via the dynamic headspace method. RSC Adv 2021; 11:21537-21547. [PMID: 35478810 PMCID: PMC9034123 DOI: 10.1039/d1ra03227e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Accepted: 06/01/2021] [Indexed: 11/21/2022] Open
Abstract
In this study, a nickel/zinc-BTC bi-metallic metal-organic framework (bi-MMOF) was employed as a new and efficient adsorbent in a needle trap device (NTD) for headspace (HS) sampling, extraction and analysis of halogenated hydrocarbons (trichloroethylene, tetrachloroethylene, chloroform, and tetrachloroethylene) from spiked and real urine samples. Characterization of the prepared adsorbent was accomplished by FT-IR, PXRD, EDX, elemental mapping, and FE-SEM techniques. According to experimental results, the optimal temperature and extraction time, salt content, temperature and desorption time of the response surface methodology (RSM) and Box-Behnken design (BBD) were determined to be 56 °C and 30 min, 5.5%, 350 °C and 8 min for the studied halogenated hydrocarbons, respectively. The calculated values of detection limit and quantitation limit parameters were in the range of 1.02-1.10 and 2.01-2.4.0 ng L-1, respectively. Moreover, intermediate precision and repeatability of the method were in the range of 4.90-8.20% and 1.50-4.80%, respectively. The recovery percentages of analytes were obtained to be in the range of 95.0-97.0% 10 days after the sampling and storage at 4 °C. This study showed that the proposed HS-NTD:Ni/Zn-BTC method coupled with a GC-FID can be employed as a simple, fast, and sensitive procedure for non-metabolized halogenated hydrocarbons from urine samples in biological monitoring.
Collapse
Affiliation(s)
- Razzagh Rahimpoor
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences Larestan Iran
| | - Ali Firoozichahak
- Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science Gonabad Iran
| | | | - Saber Alizadeh
- Department of Chemistry, Bu-Ali-Sina University Hamedan Iran
| | - Parsa Mohammad Alizadeh
- Department of Occupational Health Engineering, Faculty of Medical Sciences, Tarbiat Modares University Tehran Iran
| | | |
Collapse
|