1
|
Hatami-Fard G, Anastasova-Ivanova S. Advancements in Cerebrospinal Fluid Biosensors: Bridging the Gap from Early Diagnosis to the Detection of Rare Diseases. SENSORS (BASEL, SWITZERLAND) 2024; 24:3294. [PMID: 38894085 PMCID: PMC11174891 DOI: 10.3390/s24113294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/13/2024] [Accepted: 05/17/2024] [Indexed: 06/21/2024]
Abstract
Cerebrospinal fluid (CSF) is a body fluid that can be used for the diagnosis of various diseases. However, CSF collection requires an invasive and painful procedure called a lumbar puncture (LP). This procedure is applied to any patient with a known risk of central nervous system (CNS) damage or neurodegenerative disease, regardless of their age range. Hence, this can be a very painful procedure, especially in infants and elderly patients. On the other hand, the detection of disease biomarkers in CSF makes diagnoses as accurate as possible. This review aims to explore novel electrochemical biosensing platforms that have impacted biomedical science. Biosensors have emerged as techniques to accelerate the detection of known biomarkers in body fluids such as CSF. Biosensors can be designed and modified in various ways and shapes according to their ultimate applications to detect and quantify biomarkers of interest. This process can also significantly influence the detection and diagnosis of CSF. Hence, it is important to understand the role of this technology in the rapidly progressing field of biomedical science.
Collapse
Affiliation(s)
- Ghazal Hatami-Fard
- The Hamlyn Centre, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
| | | |
Collapse
|
2
|
Yu J, Liu Q, Qi L, Fang Q, Shang X, Zhang X, Du Y. Fluorophore and nanozyme-functionalized DNA walking: A dual-mode DNA logic biocomputing platform for microRNA sensing in clinical samples. Biosens Bioelectron 2024; 252:116137. [PMID: 38401282 DOI: 10.1016/j.bios.2024.116137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 02/12/2024] [Accepted: 02/16/2024] [Indexed: 02/26/2024]
Abstract
Inspired by the programmability and modifiability of nucleic acids, point-of-care (POC) diagnostics for nucleic acid target detection is evolving to become more diversified and intelligent. In this study, we introduce a fluorescent and photothermal dual-mode logic biosensing platform that integrates catalytic hairpin assembly (CHA), toehold-mediated stand displacement reaction (SDR) and a DNA walking machine. Dual identification and signal reporting modules are incorporated into DNA circuits, orchestrated by an AND Boolean logic gate operator and magnetic beads (MBs). In the presence of bispecific microRNAs (miRNAs), the AND logic gate activates, driving the DNA walking machine, and facilitating the collection of hairpin DNA stands modified with FAM fluorescent group and CeO2@Au nanoparticles. The CeO2@Au nanoparticles, served as a nanozyme, can oxidize TMB into oxidation TMB (TMBox), enabling a near-infrared (NIR) laser-driven photothermal effect following the magnetic separation of MBs. This versatile platform was employed to differentiate between plasma samples from breast cancer patients, lung cancer patients, and healthy donors. The thermometer-readout transducers, derived from the CeO2@Au@DNA complexes, provided reliable results, further corroborated by fluorescence assays, enhancing the confidence in the diagnostics compared to singular detection method. The dual-mode logic biosensor can be easily customized to various nucleic acid biomarkers and other POC signal readout modalities by adjusting recognition sequences and modification strategies, heralding a promising future in the development of intelligent, flexible diagnostics for POC testing.
Collapse
Affiliation(s)
- Jingyuan Yu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, PR China
| | - Quanyi Liu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, PR China
| | - Lijuan Qi
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, PR China
| | - Qi Fang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, PR China
| | - Xudong Shang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China
| | - Xiaojun Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China.
| | - Yan Du
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, PR China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, PR China.
| |
Collapse
|
3
|
Servaas S, de Vreede S, Smeets RL, Stroobants A, van Eijk LT, Malagon I, Slagt C. Validation of non-invasive point of care blood content analysis using the TensorTip™ MTX device: a method comparison study. Clin Chem Lab Med 2023; 61:1867-1874. [PMID: 37134309 DOI: 10.1515/cclm-2023-0113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 04/19/2023] [Indexed: 05/05/2023]
Abstract
OBJECTIVES The TensorTip™ MTX is a non-invasive device designed to determine several physiological parameters with additional analysis of haemoglobin, haematocrit and blood gas analysis by interpreting blood diffusion colour of the finger skin based on spectral analysis. The aim of our study was to investigate the accuracy and precision of the TensorTip MTX in a clinical setting in comparison with routine analysis of blood samples. METHODS Forty-six patients, scheduled for elective surgery, were enrolled in this study. Placement of an arterial catheter had to be part of the standard of care. Measurements were performed during the perioperative period. The measurements obtained with the TensorTip MTX were compared with the results of routine analysis of the blood samples as a reference using correlation, Bland-Altman analysis and mountain plots. RESULTS No significant correlation was present in the measurements. Measurement of haemoglobin with the TensorTip MTX had a mean bias of 0.4 mmol/L, haematocrit's bias was 3.0 %. Bias of partial pressure of carbon dioxide and oxygen was 3.6 and 66.6 mmHg, respectively. Calculated percentage errors were 48.2 , 48.9, 39.9 and 109.0 %. Proportional bias was present in all Bland-Altman analyses. Less than 95 % of the differences fell within the pre-set limits of allowable error. CONCLUSIONS Non-invasive blood content analysis with the TensorTip MTX device is not equivalent to and did not correlate sufficiently with conventional laboratory analysis. None of the parameters measured showed results within the limits of allowable error. Therefore, the use of the TensorTip MTX is not recommended for perioperative care.
Collapse
Affiliation(s)
- Sjoerd Servaas
- Department of Anaesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Silke de Vreede
- Department of Anaesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Ruben L Smeets
- Department of Laboratory Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - An Stroobants
- Department of Laboratory Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Lucas T van Eijk
- Department of Anaesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Ignacio Malagon
- Department of Anaesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Cornelis Slagt
- Department of Anaesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| |
Collapse
|
4
|
Ming J, Zeng X, Zhou R. Portable biosensor-based oral pathogenic bacteria detection for community and family applications. Anal Bioanal Chem 2023:10.1007/s00216-023-04809-1. [PMID: 37389598 DOI: 10.1007/s00216-023-04809-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 06/14/2023] [Accepted: 06/15/2023] [Indexed: 07/01/2023]
Abstract
Detection of oral pathogens is essential in the management of oral diseases, as their occurrence and progression are closely linked to an imbalance in these microorganisms. Detection techniques such as microbial cultures, enzyme-linked immunosorbent assays and polymerase chain reactions are highly dependent on complex testing procedures and specialized laboratory equipment, making prevention and early diagnosis of oral diseases difficult. To comprehensively implement oral disease prevention and early diagnosis in social groups, there is an urgent need for portable testing methods for oral pathogenic bacteria that can be applied in community and home settings. In this review, several common portable biosensors for pathogenic bacteria are first described. Based on the goal of achieving primary prevention and diagnosis of oral diseases, we elaborate and summarize portable biosensors for common oral pathogenic bacteria in terms of how to achieve portability of the technique. This review aims to reflect the current status of portable biosensors for common oral pathogens and to lay the foundation for the further realization of portable detection of oral pathogens.
Collapse
Affiliation(s)
- Jieyu Ming
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China
| | - Xin Zeng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China.
| | - Ronghui Zhou
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China.
| |
Collapse
|
5
|
Moetlhoa B, Maluleke K, Mathebula EM, Kgarosi K, Nxele SR, Lenonyane B, Mashamba-Thompson T. REASSURED diagnostics at point-of-care in sub-Saharan Africa: A scoping review. PLOS GLOBAL PUBLIC HEALTH 2023; 3:e0001443. [PMID: 37276194 DOI: 10.1371/journal.pgph.0001443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 05/12/2023] [Indexed: 06/07/2023]
Abstract
Point-of-care (POC) diagnostics that meet the REASSURED criteria are essential in combating the rapid increase and severity of global health emergencies caused by infectious diseases. However, little is known about whether the REASSURED criteria are implemented in regions known to have a high burden of infectious diseases such as sub-Saharan Africa (SSA). This scoping review maps evidence of the use of REASSURED POC diagnostic tests in SSA. The scoping review was guided by the advanced methodological framework of Arksey and O'Malley, and Levac et al. We searched the following electronic databases for relevant literature: Scopus, Dimensions, ProQuest Central, Google Scholar, and EBSCOhost (MEDLINE, CINAHL, as well as AFRICA-WIDE). Two reviewers independently screened abstracts and full-text articles using the inclusion criteria as reference. We appraised the quality of the included studies using the mixed-method appraisal tool (MMAT) version 2018. We retrieved 138 publications, comprising 134 articles and four grey literature articles. Of these, only five articles were included following abstract and full-text screening. The five included studies were all conducted in SSA. The following themes emerged from the eligible articles: quality assurance on accuracy of REASSURED POC diagnostic tests, sustainability of REASSURED POC diagnostic tests, and local infrastructure capability for delivering REASSURED POC diagnostic tests to end users. All five articles had MMAT scores between 90% and 100%. In conclusion, our scoping review revealed limited published research on REASSURED diagnostics at POC in SSA. We recommend primary studies aimed at investigating the implementation of REASSURED POC diagnostic tests in SSA.
Collapse
Affiliation(s)
- Boitumelo Moetlhoa
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Kuhlula Maluleke
- Faculty of Health Sciences, School of Health Systems and Public Health, University of Pretoria, Pretoria, South Africa
| | - Evans M Mathebula
- Faculty of Health Sciences, School of Health Systems and Public Health, University of Pretoria, Pretoria, South Africa
- Medical and Scientific Affairs, Rapid Diagnostics, Infectious Diseases Emerging Markets, Abbot Rapid Diagnostics (Pty) Ltd, Sandton, South Africa
| | - Kabelo Kgarosi
- Faculty of Health Sciences, Department of Library Services, University of Pretoria, Pretoria, South Africa
| | - Siphesihle R Nxele
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Bonolo Lenonyane
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | | |
Collapse
|
6
|
Ultrafast PCR Detection of COVID-19 by Using a Microfluidic Chip-Based System. Bioengineering (Basel) 2022; 9:bioengineering9100548. [PMID: 36290516 PMCID: PMC9598518 DOI: 10.3390/bioengineering9100548] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/02/2022] [Accepted: 10/10/2022] [Indexed: 11/17/2022] Open
Abstract
With the evolution of the pandemic caused by the Coronavirus disease of 2019 (COVID-19), reverse transcriptase-polymerase chain reactions (RT-PCR) have invariably been a golden standard in clinical diagnosis. Nevertheless, the traditional polymerase chain reaction (PCR) is not feasible for field application due to its drawbacks, such as time-consuming and laboratory-based dependence. To overcome these challenges, a microchip-based ultrafast PCR system called SWM-02 was proposed to make PCR assay in a rapid, portable, and low-cost strategy. This novel platform can perform 6-sample detection per run using multiple fluorescent channels and complete an ultrafast COVID-19 RT-PCR test within 40 min. Here, we evaluated the performance of the microdevice using the gradient-diluted COVID-19 reference samples and commercial PCR kit and determined its limit-of-detection (LoD) as 500 copies/mL, whose variation coefficients for the nucleocapsid (N) gene and open reading frame 1 ab region (ORF1ab) gene are 1.427% and 0.7872%, respectively. The system also revealed an excellent linear correlation between cycle threshold (Ct) values and dilution factors (R2 > 0.99). Additionally, we successfully detected the target RNAs and internal gene in the clinical samples by fast PCR, which shows strong consistency with conventional PCR protocol. Hence, with compact dimension, user-friendly design, and fast processing time, SWM-02 has the capability of offering timely and sensitive on-site molecular diagnosis for prevention and control of pathogen transmission.
Collapse
|
7
|
Hussain M, Zou J, Zhang H, Zhang R, Chen Z, Tang Y. Recent Progress in Spectroscopic Methods for the Detection of Foodborne Pathogenic Bacteria. BIOSENSORS 2022; 12:bios12100869. [PMID: 36291007 PMCID: PMC9599795 DOI: 10.3390/bios12100869] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 10/07/2022] [Accepted: 10/09/2022] [Indexed: 05/06/2023]
Abstract
Detection of foodborne pathogens at an early stage is very important to control food quality and improve medical response. Rapid detection of foodborne pathogens with high sensitivity and specificity is becoming an urgent requirement in health safety, medical diagnostics, environmental safety, and controlling food quality. Despite the existing bacterial detection methods being reliable and widely used, these methods are time-consuming, expensive, and cumbersome. Therefore, researchers are trying to find new methods by integrating spectroscopy techniques with artificial intelligence and advanced materials. Within this progress report, advances in the detection of foodborne pathogens using spectroscopy techniques are discussed. This paper presents an overview of the progress and application of spectroscopy techniques for the detection of foodborne pathogens, particularly new trends in the past few years, including surface-enhanced Raman spectroscopy, surface plasmon resonance, fluorescence spectroscopy, multiangle laser light scattering, and imaging analysis. In addition, the applications of artificial intelligence, microfluidics, smartphone-based techniques, and advanced materials related to spectroscopy for the detection of bacterial pathogens are discussed. Finally, we conclude and discuss possible research prospects in aspects of spectroscopy techniques for the identification and classification of pathogens.
Collapse
Affiliation(s)
- Mubashir Hussain
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
- Postdoctoral Innovation Practice, Shenzhen Polytechnic, Liuxian Avenue, Nanshan District, Shenzhen 518055, China
| | - Jun Zou
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
- Correspondence: (Z.J.); (T.Y.)
| | - He Zhang
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
| | - Ru Zhang
- School of Materials and Chemical Engineering, Hunan Institute of Engineering, Xiangtan 411104, China
| | - Zhu Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou 412007, China
| | - Yongjun Tang
- Postdoctoral Innovation Practice, Shenzhen Polytechnic, Liuxian Avenue, Nanshan District, Shenzhen 518055, China
- Correspondence: (Z.J.); (T.Y.)
| |
Collapse
|
8
|
Huang LL, Wang ZJ, Xie HY. Photoluminescent inorganic nanoprobe-based pathogen detection. Chem Asian J 2022; 17:e202200475. [PMID: 35758547 DOI: 10.1002/asia.202200475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 06/20/2022] [Indexed: 11/05/2022]
Abstract
Pathogens are serious threats to human health, and traditional detection techniques suffer from various limitations. The unique optical properties of photoluminescent inorganic nanomaterials, such as high photoluminescence quantum yields, good photostability, and tunable spectrum, make them ideal tools for the detection of pathogens with high specificity and sensitivity. In this review, the design strategies, working mechanisms, and applications of photoluminescent inorganic nanomaterial-based probes in pathogen detection are introduced. In particular, the design and construction of stimuli-responsive nanoprobes and their potential in these fields are highlighted.
Collapse
Affiliation(s)
- Li-Li Huang
- Beijing Institute of Technology, School of Medical Technology, , 100081, , CHINA
| | - Zhong-Jie Wang
- Beijing Institute of Technology, School of Medical Technology, CHINA
| | - Hai-Yan Xie
- Beijing Institute Of Technology School of Life Science, School of Life science, south 5 zhongguancun street, 100081, Beijing, CHINA
| |
Collapse
|
9
|
Chi Y, Shi M, Wu Y, Wu Y, Chang Y, Liu M. Single bacteria detection by droplet DNAzyme-coupled rolling circle amplification. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2244-2248. [PMID: 35611869 DOI: 10.1039/d2ay00656a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
We described a new system termed droplet DNAzyme-coupled rolling circle amplification (dDRCA) that can selectively detect bacteria from clinical urine samples with single-cell sensitivity within 1.5 h compared with the several hours needed for traditionally used culture-based methods.
Collapse
Affiliation(s)
- Yanchen Chi
- School of Environmental Science and Technology, Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education), Dalian University of Technology, Dalian POCT Laboratory, Dalian, 116024, China.
| | - Meng Shi
- School of Environmental Science and Technology, Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education), Dalian University of Technology, Dalian POCT Laboratory, Dalian, 116024, China.
| | - Yanfang Wu
- School of Chemistry and Australian Centre for Nano Medicine, The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Yunping Wu
- School of Environmental Science and Technology, Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education), Dalian University of Technology, Dalian POCT Laboratory, Dalian, 116024, China.
| | - Yangyang Chang
- School of Environmental Science and Technology, Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education), Dalian University of Technology, Dalian POCT Laboratory, Dalian, 116024, China.
| | - Meng Liu
- School of Environmental Science and Technology, Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education), Dalian University of Technology, Dalian POCT Laboratory, Dalian, 116024, China.
| |
Collapse
|
10
|
Totoricaguena-Gorriño J, Dei M, Alba AF, Peřinka N, Rubio LR, Vilas-Vilela JL, del Campo FJ. Toward Next-Generation Mobile Diagnostics: Near-Field Communication-Powered Electrochemiluminescent Detection. ACS Sens 2022; 7:1544-1554. [PMID: 35559616 DOI: 10.1021/acssensors.2c00425] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Mobile phones have been used in combination with point of care (PoC) devices for over a decade now. However, their use seems restricted to the detection of sensing events using the video and camera functions. In contrast, the complementary ability to use mobile phones to power such PoC devices has been largely unexplored. This work demonstrates the proof-of-principle that a smartphone can be used to both power and analyze an electrochemiluminescence (ECL) detection system. A printed device is presented featuring an electrochemical cell connected in series to a rectenna that is able to use the Near Field Communication (NFC, 13.56 MHz) signal to provide the energy needed to generate ECL from Ru(bpy)32+/tri-n-propylamine. The emitted light, the intensity of which is directly proportional to the concentration of the ruthenium complex, can then be captured by the mobile phone camera and analyzed. This work presents the fabrication and the electrical and electrochemical characterization of the device. Effective voltages ranging from 0.90 to 4.50 V have been recorded, depending on the coupling between emitter and receiver, which translate into working electrode potentials ranging from 0.76 up to 1.79 V vs Ag. Detection and quantification limits of 0.64 and 1.52 μM, respectively, have been achieved for Ru(bpy)32+, and linear ranges up to 0.1 mM (red channel) and no less than 1.0 mM (green channel) have been found.
Collapse
Affiliation(s)
- Joseba Totoricaguena-Gorriño
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Vizcaya, Spain
| | - Michele Dei
- Department of Information Engineering, University of Pisa, 56122 - Pisa, Italy
| | - Alejandro Fidel Alba
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Vizcaya, Spain
- Grupo de Química Macromolecular, Departamento Química-Física, Universidad del País Vasco, UPV-EHU, 48940 Leioa, Vizcaya, Spain
| | - Nikola Peřinka
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Vizcaya, Spain
| | - Leire-Ruiz Rubio
- Grupo de Química Macromolecular; Departamento Química-Física, Universidad del País Vasco, UPV-EHU, 48940 Leioa, Vizcaya, Spain
| | - José Luis Vilas-Vilela
- Grupo de Química Macromolecular; Departamento Química-Física, Universidad del País Vasco, UPV-EHU, 48940 Leioa, Vizcaya, Spain
| | - Francisco Javier del Campo
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Vizcaya, Spain
- IKERBASQUE, Basque Foundation for Science, 48009, Bilbao, Spain
| |
Collapse
|