1
|
Lee DL, Baptist AP. Understanding the Updates in the Asthma Guidelines. Semin Respir Crit Care Med 2022; 43:595-612. [PMID: 35728605 DOI: 10.1055/s-0042-1745747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Asthma is a chronic inflammatory lung disease that affects millions of Americans, with variable symptoms of bronchospasm and obstruction among individuals over time. The National Heart, Lung, and Blood Institute (NHLBI) published the 2020 Focused Updates to the Asthma Management Guidelines based on the latest research since the 2007 Expert Panel Report-3 (EPR-3). The following article reviews the 21 new recommendations on the six core topics in asthma: use of intermittent inhaled corticosteroids, long-acting muscarinic antagonist therapy, use of the fractional exhaled nitric oxide test in asthma diagnosis and monitoring, indoor allergen mitigation, immunotherapy, and bronchial thermoplasty. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach was used to rate recommendations as strong or conditional based on the evidence. The recommendations were based on systematic reviews of the literature and focused on patient-centered critical outcomes of asthma exacerbations, asthma control, and asthma-related quality of life. Understanding the recommendations with consideration of individual values through shared decision-making may improve asthma outcomes.
Collapse
Affiliation(s)
- Deborah L Lee
- Department of Internal Medicine, Division of Allergy and Clinical Immunology, University of Michigan, Ann Arbor, MI
| | - Alan P Baptist
- Department of Internal Medicine, Division of Allergy and Clinical Immunology, University of Michigan, Ann Arbor, MI
| |
Collapse
|
2
|
Cloutier MM, Baptist AP, Blake KV, Brooks EG, Bryant-Stephens T, DiMango E, Dixon AE, Elward KS, Hartert T, Krishnan JA, Lemanske RF, Ouellette DR, Pace WD, Schatz M, Skolnik NS, Stout JW, Teach SJ, Umscheid CA, Walsh CG. 2020 Focused Updates to the Asthma Management Guidelines: A Report from the National Asthma Education and Prevention Program Coordinating Committee Expert Panel Working Group. J Allergy Clin Immunol 2020; 146:1217-1270. [PMID: 33280709 PMCID: PMC7924476 DOI: 10.1016/j.jaci.2020.10.003] [Citation(s) in RCA: 403] [Impact Index Per Article: 100.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Accepted: 10/06/2020] [Indexed: 12/22/2022]
Abstract
The 2020 Focused Updates to the Asthma Management Guidelines: A Report from the National Asthma Education and Prevention Program Coordinating Committee Expert Panel Working Group was coordinated and supported by the National Heart, Lung, and Blood Institute (NHLBI) of the National Institutes of Health. It is designed to improve patient care and support informed decision making about asthma management in the clinical setting. This update addresses six priority topic areas as determined by the state of the science at the time of a needs assessment, and input from multiple stakeholders:A rigorous process was undertaken to develop these evidence-based guidelines. The Agency for Healthcare Research and Quality's (AHRQ) Evidence-Based Practice Centers conducted systematic reviews on these topics, which were used by the Expert Panel Working Group as a basis for developing recommendations and guidance. The Expert Panel used GRADE (Grading of Recommendations, Assessment, Development and Evaluation), an internationally accepted framework, in consultation with an experienced methodology team for determining the certainty of evidence and the direction and strength of recommendations based on the evidence. Practical implementation guidance for each recommendation incorporates findings from NHLBI-led patient, caregiver, and clinician focus groups. To assist clincians in implementing these recommendations into patient care, the new recommendations have been integrated into the existing Expert Panel Report-3 (EPR-3) asthma management step diagram format.
Collapse
Affiliation(s)
- Michelle M Cloutier
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Alan P Baptist
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Kathryn V Blake
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Edward G Brooks
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Tyra Bryant-Stephens
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Emily DiMango
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Anne E Dixon
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Kurtis S Elward
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Tina Hartert
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Jerry A Krishnan
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Robert F Lemanske
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Daniel R Ouellette
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Wilson D Pace
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Michael Schatz
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Neil S Skolnik
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - James W Stout
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Stephen J Teach
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Craig A Umscheid
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| | - Colin G Walsh
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda
| |
Collapse
|
3
|
van Boven FE, de Jong NW, Braunstahl GJ, Gerth van Wijk R, Arends LR. A meta-analysis of baseline characteristics in trials on mite allergen avoidance in asthmatics: room for improvement. Clin Transl Allergy 2020; 10:2. [PMID: 31921410 PMCID: PMC6943957 DOI: 10.1186/s13601-019-0306-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Accepted: 12/13/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Evidence regarding the clinical effectiveness of mite allergen avoidance for the treatment of asthma is lacking. In previous meta-analyses on mite allergen control, the baseline data were not discussed in detail. This study updates and extends the existing Cochrane review by Gøtzsche and Johansen (Cochrane Database of Systematic Reviews, 2008, Art. No: CD001187), with a focus on baseline asthma outcomes and allergen exposures. METHODS We used the existing trials in the original Cochrane review and included newly published studies. The baseline data for the mite allergen load from the mattress, the standardized asthma symptom score (ASS), the forced expiratory volume in 1 s percentage of predicted (FEV1 %pred.), and the histamine provocative concentration causing a 20% drop in FEV1 (PC20) were extracted. First, the mean values of the outcomes were calculated. The influence of the mite allergen load was examined with a random-effect meta-regression using the Metafor package in R. RESULTS Forty-five trials were included; 39 trials reported strategies for concurrent bedroom interventions, and 6 trails reported strategies for air purification. The mite allergen load ranged from 0.44 to 24.83 μg/g dust, with a mean of 9.86 μg/g dust (95% CI 5.66 to 14.05 μg/g dust, I2 = 99.8%). All health outcomes showed considerable heterogeneity (standardized ASS mean: 0.13, 95% CI 0.08 to 0.18, I2 = 99.9%; FEV1 %pred. mean: 85.3%, 95% CI 80.5 to 90.1%, I2 = 95.8%; PC20 mean: 1.69 mg/mL, 95% CI 0.86 to 2.52 mg/mL, I2 = 95.6%). The covariate mite allergen load did not significantly influence health outcomes. DISCUSSION This meta-analysis shows that mite avoidance studies are characterized by the inclusion of patients with rather mild to moderate asthma and with varying and sometimes negligible levels of allergen exposure. Future studies should focus on patients with severe asthma and increased levels of allergen exposure.
Collapse
Affiliation(s)
- Frank E. van Boven
- Department of Internal Medicine, Section of Allergology & Clinical Immunology, Erasmus Medical Center, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands
| | - Nicolette W. de Jong
- Department of Internal Medicine, Section of Allergology & Clinical Immunology, Erasmus Medical Center, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands
| | - Gert-Jan Braunstahl
- Department of Pulmonology, Sint Franciscus Vlietland Groep, P.O. Box 10900, 3004 BA Rotterdam, The Netherlands
- Department of Pulmonology, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Roy Gerth van Wijk
- Department of Internal Medicine, Section of Allergology & Clinical Immunology, Erasmus Medical Center, P.O. Box 2040, 3000 CA Rotterdam, The Netherlands
| | - Lidia R. Arends
- Department of Biostatistics, Erasmus Medical Center, Rotterdam, The Netherlands
- Department of Psychology, Education & Child Studies, Erasmus University Rotterdam, P.O. Box 1738, 3000 DR Rotterdam, The Netherlands
| |
Collapse
|
4
|
van Boven FE, Arends LR, Braunstahl G, van Wijk RG. A reintroduction of environmental mite allergen control strategies for asthma treatment and the debate on their effectiveness. Clin Exp Allergy 2019; 49:400-409. [PMID: 30659677 PMCID: PMC6850033 DOI: 10.1111/cea.13340] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 12/21/2018] [Accepted: 01/09/2019] [Indexed: 12/19/2022]
Abstract
Asthma affects three hundred million people worldwide. The effectiveness of house dust mite allergen control for asthma treatment is debatable. One aspect that has been little discussed in existing meta-analyses is the possible role of environmental strategies. Here, we reintroduce the previously defined strategies for mite allergen control and discuss their importance to the debate on clinical effectiveness. The strategy of concurrent bedroom interventions is related to the combined use of a priori defined interventions, while the strategy of exposure-based control relates to the treatment of relevant textiles after assessing exposure. The air purification strategy aims to purify the human breathing zone of airborne allergens. In Western European patient practice, the use of these strategies differs. A post hoc study of the dominant Cochrane review by Gøtzsche and Johansen (Cochrane Database of Systematic Reviews, 2008, Art. No: CD001187) appears to indicate that a majority of the underlying trials reported on the strategy of concurrent bedroom interventions, which were mainly executed in a minimal manner. Some trials have reported on the air purification strategy and may potentially alter the debate on effectiveness. No trial has reported on the strategy of exposure-based control. We therefore hypothesize that the absence of evidence for the effectiveness of mite allergen control for asthma treatment applies to the strategy of concurrent bedroom interventions. The evidence-based effectiveness of the exposure-based control strategy appears to be undetermined. The results of our post hoc reanalysis urge that future meta-analyses of mite allergen control should a priori define the environmental strategy under study. Future trials of mite allergen control are warranted to test the exposure-based strategy as well as the sparsely tested strategy of air purification.
Collapse
Affiliation(s)
- Frank E. van Boven
- Department of Internal MedicineSection of AllergologyErasmus Medical CenterRotterdamThe Netherland
| | - Lidia R. Arends
- Department of BiostatisticsErasmus Medical CenterRotterdamThe Netherlands
- Department of Psychology, Education & Child StudiesErasmus University RotterdamRotterdamThe Netherlands
| | - Gert‐Jan Braunstahl
- Department of PulmonologySint Franciscus Vlietland GroepRotterdamThe Netherlands
- Department of PulmonologyErasmus Medical CenterRotterdamThe Netherlands
| | - Roy Gerth van Wijk
- Department of Internal MedicineSection of AllergologyErasmus Medical CenterRotterdamThe Netherland
| |
Collapse
|
5
|
Leas BF, D'Anci KE, Apter AJ, Bryant-Stephens T, Lynch MP, Kaczmarek JL, Umscheid CA. Effectiveness of indoor allergen reduction in asthma management: A systematic review. J Allergy Clin Immunol 2018; 141:1854-1869. [DOI: 10.1016/j.jaci.2018.02.001] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Revised: 01/16/2018] [Accepted: 02/02/2018] [Indexed: 10/18/2022]
|
6
|
van Boven FE. Effectiveness of mite-impermeable covers: a hypothesis-generating meta-analysis. Clin Exp Allergy 2015; 44:1473-83. [PMID: 25048696 DOI: 10.1111/cea.12376] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Asthma is a heterogeneous disease. The subject of mite allergen control has evolved into a debate dominated by a Cochrane review by Gøtzsche and Johansen (Cochrane Database of Systematic Reviews, 2008, Art. No: CD001187). A not well-discussed aspect of that study is the selection by those authors of a univariate meta-analysis including various interventions. This study extends the meta-analysis by Gøtzsche and Johansen and aims to generate hypotheses on the effectiveness of various bedding interventions, including the coverage of all bedding elements. Trials were selected based on environmental criteria. The interventions were classified according to the number of barriers used. Standardized mean differences yielded the mite load, three physiological outcomes and asthma symptom scores. The influence of covariates was examined with a mixed-effect model using the metafor package for meta-analysis in R. Twelve trials included 1187 observations. The interventions included one barrier or product (six trials), two barriers or partial control (four trials) and three barriers or integral control (two trials). The exposure data showed considerable heterogeneity (I(2) = 93%). The risk of bias significantly (P = 0.04) influenced the final load, the square root of the interaction between the baseline load and the type of intervention as well (95% CI: -0.66 to -0.07 μg/g; P = 0.02). Changes in load showed similar tendencies. Health outcomes showed moderate to considerable heterogeneity (physiological outcomes I(2) = 44-94%; symptom score I(2) = 93%). A meta-regression of bedding interventions indicates that integral control most significantly reduced mite load when the load was high at baseline. The number of trials was too small to allow an appropriate examination of health outcomes. Future studies are suggested to test the hypothesis that allergic patients benefit from integral control when the baseline mite load is high.
Collapse
Affiliation(s)
- F E van Boven
- Working Group on Allergen Avoidance, V&VN Lung Care Nurses, V&VN Dutch Nurses' Association, Utrecht, The Netherlands
| |
Collapse
|
7
|
Abstract
Dust mites, cockroaches, and pets (cats, dogs) are common in homes worldwide, and many species are the source of potent allergens which cause allergic diseases. These diseases are influenced by genetic predisposition and environmental exposure. Generally, the levels of house dust mite (Der p 1 and Der f 1) and cockroach (Bla g 1, Bla g 2) allergens are used as markers of indoor exposure to arthropods.This article reviews the findings of allergens Der p 1, Der f 1, and Bla g 1 in randomly selected urban households in Zagreb (Croatia) measured from 2006 to 2010 and compares them with exposure to arthropod allergens in other countries. In short, house dust mite allergen levels in Croatian homes are low, but exposure is common; Der p 1 was found in 73 % and Der f 1 in 83 % of the households. By contrast, exposure to cockroach allergen Bla g 1 was both low and uncommon (13 %). Exposure to multiple allergens associated with sensitisation and asthma was not frequent in urban homes in Croatia. However, further studies should include monitoring of both arthropod and pet allergens in high-risk populations in inland and coastal Croatia. They should also investigate a complex dose-response relationship between exposure and sensitisation/asthma development, especially in early childhood.
Collapse
|
8
|
Abstract
The major allergen in house dust comes from mites. We performed a systematic review of the randomized trials that had assessed the effects of reducing exposure to house dust mite antigens in the homes of people with mite-sensitive asthma, and had compared active interventions with placebo or no treatment. Fifty-four trials (3002 patients) were included. Thirty-six trials assessed physical methods (26 mattress covers), 10 chemical methods and eight a combination of chemical and physical methods. Despite the fact that many trials were of poor quality and would be expected to exaggerate the reported effect, we did not find an effect of the interventions. For the most frequently reported outcome, peak flow in the morning (1565 patients), the standardized mean difference was 0.00 (95% confidence interval (CI) -0.10 to 0.10). There were no statistically significant differences in number of patients improved (relative risk 1.01, 95% CI 0.80-1.27), asthma symptom scores (standardized mean difference -0.04, 95% CI -0.15 to 0.07) or in medication usage (standardized mean difference -0.06, 95% CI -0.18 to 0.07). Chemical and physical methods aimed at reducing exposure to house dust mite allergens cannot be recommended.
Collapse
Affiliation(s)
- P C Gøtzsche
- Nordic Cochrane Centre, Rigshospitalet, Copenhagen, Denmark
| | | |
Collapse
|
9
|
Abstract
EDITORIAL NOTE This 2011 review predates current reporting standards and methodological expectations for Cochrane Reviews. It should not be used for clinical decision‐making. BACKGROUND The major allergen in house dust comes from mites. Chemical, physical and combined methods of reducing mite allergen levels are intended to reduce asthma symptoms in people who are sensitive to house dust mites. OBJECTIVES To assess the effects of reducing exposure to house dust mite antigens in the homes of people with mite-sensitive asthma. SEARCH STRATEGY PubMed and The Cochrane Library (last searches Nov 2007), reference lists. SELECTION CRITERIA Randomised trials of mite control measures vs placebo or no treatment in people with asthma known to be sensitive to house dust mites. DATA COLLECTION AND ANALYSIS Two authors applied the trial inclusion criteria and evaluated the data. Trial authors were contacted to clarify information. MAIN RESULTS Fifty-four trials (3002 patients) were included. Thirty-six trials assessed physical methods (26 mattress encasings), 10 chemical methods, and 8 a combination of chemical and physical methods. Despite the fact that many trials were of poor quality and would be expected to exaggerate the reported effect, we did not find an effect of the interventions. For the most frequently reported outcome, peak flow in the morning (1565 patients), the standardised mean difference was 0.00 (95% confidence interval (CI) -0.10 to 0.10). There were no statistically significant differences either in number of patients improved (relative risk 1.01, 95% CI 0.80 to 1.27), asthma symptom scores (standardised mean difference -0.04, 95% CI -0.15 to 0.07), or in medication usage (standardised mean difference -0.06, 95% CI -0.18 to 0.07). AUTHORS' CONCLUSIONS Chemical and physical methods aimed at reducing exposure to house dust mite allergens cannot be recommended. It is doubtful whether further studies, similar to the ones in our review, are worthwhile. If other types of studies are considered, they should be methodologically rigorous and use other methods than those used so far, with careful monitoring of mite exposure and relevant clinical outcomes.
Collapse
Affiliation(s)
- P C Gøtzsche
- Rigshospitalet, Dept. 3343, Nordic Cochrane Centre. Blegdamsvej 9, Copenhagen Ø, Denmark, 2100.
| | | |
Collapse
|
10
|
von Hertzen LC, Laatikainen T, Pennanen S, Mäkelä MJ, Haahtela T. Is house dust mite monosensitization associated with clinical disease? Allergy 2008; 63:379-81. [PMID: 18269683 DOI: 10.1111/j.1398-9995.2007.01595.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- L C von Hertzen
- Skin and Allergy Hospital, PO Box 160, 000029 Huch, Finland.
| | | | | | | | | |
Collapse
|
11
|
van den Bemt L, de Vries MP, Cloosterman S, Thoonen B, Muris JWM, Goossens M, Wesseling G, van Schayck CP. Influence of house dust mite impermeable covers on health-related quality of life of adult patients with asthma: results of a randomized clinical trial. J Asthma 2008; 44:843-8. [PMID: 18097861 DOI: 10.1080/02770900701752318] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
The aim of this study was to evaluate the effect of house dust mite impermeable covers on asthma-specific health-related quality of life in adult asthmatic patients that were trained in guided self-management. In a 2-year randomized placebo-controlled clinical trial, information on the quality of life was collected. The improvement of Mini Asthma Quality of Life Questionnaire (AQLQ) score in the allergens-avoidance group (0.26) was comparable to the improvement in the placebo group (0.30) and not significant. HDM-impermeable covers for pillows, duvets, and mattresses did not result in improved health-related quality of life.
Collapse
Affiliation(s)
- Lisette van den Bemt
- Department of General Practice, Radboud University Nijmegen Medical Centre, The Netherlands.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
van Schayck OCP, Maas T, Kaper J, Knottnerus AJA, Sheikh A. Is there any role for allergen avoidance in the primary prevention of childhood asthma? J Allergy Clin Immunol 2007; 119:1323-8. [PMID: 17399772 DOI: 10.1016/j.jaci.2007.02.024] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2007] [Revised: 02/16/2007] [Accepted: 02/20/2007] [Indexed: 10/23/2022]
Abstract
In this article we discuss 3 hypotheses to attempt to understand why preventive measures thus far studied with the aim of preventing (or delaying) the development of asthma have shown such disappointing results. The most likely explanation is that the development of a multifactorial disease, such as asthma, is extremely difficult, if not impossible, to prevent by eliminating only one risk factor. In a meta-analysis we investigated the effect of a multifaceted and monofaceted intervention in 10 prospective birth cohorts of a total of 3473 children on a diagnosis of asthma. Multifaceted intervention studies had an odds ratio (OR) of 0.73 (95% CI, 0.55-0.97), whereas the monointervention studies had an OR of 1.22 (95% CI, 0.83-1.78) in patients younger than 5 years and an OR of 0.52 (95% CI, 0.32-0.84) versus 0.93 (95% CI, 0.66-1.31) in patients older than 5 years. We therefore hypothesize that studies with a multifaceted approach will have a much greater chance of being successful than studies using a monofaceted approach, with the latter being unlikely to yield a clinically relevant reduction of asthma.
Collapse
Affiliation(s)
- Onno C P van Schayck
- Department of General Practice, Research Institute Caphri, Maastricht University, Maastricht, The netherlands.
| | | | | | | | | |
Collapse
|
13
|
Walters EH, Gibson PG, Lasserson TJ, Walters JAE. Long-acting beta2-agonists for chronic asthma in adults and children where background therapy contains varied or no inhaled corticosteroid. Cochrane Database Syst Rev 2007; 2007:CD001385. [PMID: 17253458 PMCID: PMC10849111 DOI: 10.1002/14651858.cd001385.pub2] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND Asthma is a common respiratory disease among both adults and children and short acting inhaled beta-2 agonists are used widely for 'reliever' bronchodilator therapy. Long acting beta-2 agonists (LABA) were introduced as prospective 'symptom controllers' in addition to inhaled corticosteroid 'preventer' therapy (ICS). In this updated review we have included studies in which patients were either not on ICS as a group, or in which some patients, but not all, were on ICS to complement previous systematic reviews of studies where LABA was given in patients uniformly receiving ICS. We have focussed particularly on serious adverse events, given previous concerns about potential risks, especially of death, from regular beta-2 agonist use. OBJECTIVES This review aimed to determine the benefit or detriment on the primary outcome of asthma control with the regular use of LABA compared with placebo, in mixed populations in which only some were taking ICS and in populations not using ICS therapy. SEARCH STRATEGY We carried out searches using the Cochrane Airways Group trial register, most recently in October 2005. We searched bibliographies of identified RCTs for additional relevant RCTs and contacted authors of identified RCTs for other published and unpublished studies. SELECTION CRITERIA All randomised studies of at least four weeks duration, comparing a LABA given twice daily with a placebo, in chronic asthma. Selection criteria to this updated review have been altered to accommodate recently published Cochrane reviews on combination and addition of LABA to ICS therapy. Studies in which all individuals were uniformly taking ICS were excluded from this review. DATA COLLECTION AND ANALYSIS Two reviewers performed data extraction and study quality assessment independently. We contacted authors of studies for missing data. MAIN RESULTS Sixty-seven studies (representing 68 experimental comparisons) randomising 42,333 participants met the inclusion criteria. Salmeterol was used as long-acting agent in 50 studies and formoterol fumarate in 17. The treatment period was four to nine weeks in 29 studies, and 12 to 52 weeks in 38 studies. Twenty-four studies did not permit the use of ICS, and forty permitted either inhaled corticosteroid or cromones (in three studies this was unclear). In these studies between 22% and 92% were taking ICS, with a median of 62%. There were significant advantages to LABA treatment compared to placebo for a variety of measurements of airway calibre including morning peak expiratory flow (PEF), evening PEF and FEV1. They were associated with significantly fewer symptoms, less use of rescue medication and higher quality of life scores. This was true whether patients were taking LABA in combination with ICS or not. Findings from SMART (a recently published surveillance study) indicated significant increases in asthma related deaths, respiratory related deaths and combined asthma related deaths and life threatening experiences. The absolute increase in asthma-related mortality was consistent with an increase of around one per 1250 patients treated with LABA for six months, but the confidence intervals are wide (from 700 to 10,000). Post-hoc exploratory subgroups suggested that African-Americans and those not on inhaled corticosteroids were at particular risk for the primary end-point of death or life-threatening asthma event. There was also a suggestion of an increase in exacerbation rate in children. Pharmacologically predicted side effects such as headache, throat irritation, tremor and nervousness were more frequent with LABA treatment. AUTHORS' CONCLUSIONS LABA are effective in the control of chronic asthma in the "real-life" subject groups included. However there are potential safety issues which call into question the safety of LABA, particularly in those asthmatics who are not taking ICS, and it is not clear why African-Americans were found to have significant differences in comparison to Caucasians for combined respiratory-related death and life threatening experiences, but not for asthma-related death.
Collapse
Affiliation(s)
- E H Walters
- University of Tasmania Medical School, Discipline of Medicine, 43 , Collins Street, PO BOX 252-34, Hobart, Tasmania, Australia, 7001.
| | | | | | | |
Collapse
|
14
|
Semic Jusufagic A, Simpson A, Woodcock A. Dust mite allergen avoidance as a preventive and therapeutic strategy. Curr Allergy Asthma Rep 2006; 6:521-6. [PMID: 17026879 DOI: 10.1007/s11882-006-0031-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Asthma is a global health problem with genetic and environmental components. Indoor allergens have a major impact on asthma, and exposure in sensitized subjects can compromise lung function. A reduction in allergen exposure would seem a logical facet to treatment. Methods for reducing mite allergen levels that are effective in the laboratory may not work in the home and may not result in a clinical benefit. Six ongoing studies are investigating the effects of environmental control on the primary prevention of asthma and allergies. Although the Isle of Wight and Canadian studies provide encouraging results at age 8 and 7 years, respectively, it will be some time before a definitive public health message emerges. For secondary prevention, there is little evidence to support the use of mite-proof encasings as a single intervention in adults. In children, however, single or multifaceted interventions appear to be of some benefit.
Collapse
Affiliation(s)
- Aida Semic Jusufagic
- Academic Division of Medicine and Surgery, 2nd Floor Education and Research Center, University of Mancester, Wythenshawe Hospital, Southmoor Road, Mancester M23 9LT, UK
| | | | | |
Collapse
|
15
|
Bemt L, Vries MP, Knapen L, Jansen M, Goossens M, Muris JWM, Schayck CP. Influence of mattress characteristics on house dust mite allergen concentration. Clin Exp Allergy 2006; 36:233-7. [PMID: 16433862 DOI: 10.1111/j.1365-2222.2006.02427.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Exposure to a high level of house dust mite allergens (HDMAs) is considered as a risk factor for HDM sensitization and development of asthma in genetically disposed people. Mattresses are one of the most important sources of HDMA in people's living environment. OBJECTIVE The aim of this study was to evaluate the association between mattress characteristics and HDMA concentrations on mattresses. METHODS Dust samples of mattress surfaces were taken to evaluate the level of Der p 1 allergen. All participants filled in a questionnaire about the type of mattress, the type of covering (upper layer) of the mattress, dwelling characteristics and cleaning habits. Humidity and temperature of the bedroom were measured at the time of dust sampling. RESULTS One hundred and sixty-eight questionnaires were filled in. Synthetic upper layer of the mattress was associated with a higher level of Der p 1 compared with cotton upper layer (2.6 vs. 0.8 microg/g Der p 1). Moreover, higher relative humidity (RH) was associated with significant higher concentrations and density of Der p 1. CONCLUSIONS Two factors were associated with lower levels of Der p 1 found on mattresses, namely: a cotton upper layer of the mattress compared with a layer of synthetic material and lower RH at the time of sampling. As far as we know, the association between type of upper layer and concentration of Der p 1 has not been described before and could lead to the formulation of practical advices in order to reduce HDMA concentrations on mattresses.
Collapse
Affiliation(s)
- L Bemt
- Department of General Practice, Research Institute Caphri, Maastricht University, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
16
|
Sercombe JK, Liu-Brennan D, Causer SM, Tovey ER. The vertical distribution of house dust mite allergen in carpet and the effect of dry vacuum cleaning. Int J Hyg Environ Health 2006; 210:43-50. [PMID: 16887391 DOI: 10.1016/j.ijheh.2006.06.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2006] [Revised: 05/15/2006] [Accepted: 06/28/2006] [Indexed: 11/22/2022]
Abstract
BACKGROUND Carpets are large reservoirs of the dust mite allergen Der p 1. The effect of vacuum cleaning on the distribution of Der p 1 in carpets is poorly understood. METHODS Samples were cut from 7 used household carpets, all over 5 years of age. From each carpet, 10 samples were left untreated, 10 vacuumed with an upright vacuum cleaner, and 10 vacuumed with a canister vacuum cleaner. Each section was then cut into 3 horizontal layers: the top 2mm, the remainder of the carpet pile, and the carpet base. The mass of Der p 1 as a proportion of carpet volume was then determined. RESULTS The concentrations of Der p 1 in each depth layer varied considerably between the 7 untreated carpets. In the top layer, Der p 1 concentrations were (median; 25th-75th percentiles): 41.9; 28.3-92.6 pg/mm3. For the middle layer they were similar (38.1; 22.4-108.5 pg/mm3), and for the carpet base, higher (212.4; 98.8-456.2 pg/mm3). In most cases, cleaning using either type of vacuum cleaner resulted in no significant reduction in allergen concentration throughout all depth layers. A subset of carpets showed an apparent increase in Der p 1 concentration in one or more layers following vacuum cleaning. In all tests Der p 1 was collected in the vacuum cleaners' filter bags. CONCLUSIONS The depth-distribution of Der p 1 differs widely amongst used carpets. Vacuum cleaning changes the distribution of Der p 1 within such carpets but does not necessarily result in a reduction in the overall content.
Collapse
Affiliation(s)
- Jason K Sercombe
- Woolcock Institute of Medical Research, University of Sydney, Sydney, Australia.
| | | | | | | |
Collapse
|
17
|
Liccardi G, Cazzola M, Walter Canonica G, Passalacqua G, D'Amato G. New insights in allergen avoidance measures for mite and pet sensitized patients. A critical appraisal. Respir Med 2006; 99:1363-76. [PMID: 15890511 DOI: 10.1016/j.rmed.2005.03.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2004] [Accepted: 03/09/2005] [Indexed: 11/20/2022]
Abstract
It is widely acknowledged that avoidance of allergens such as those derived from foods, drugs, latex and stinging insects results in a complete disappearance of symptoms. By contrast, although it has been clearly shown that allergens are an important risk factor for the development of respiratory symptoms and that several avoidance measures reduce allergen levels, whether this gives clinical improvement in symptoms is debatable. Many reasons could be invoked to justify this evident discrepancy. Apart from the intrinsic methodological aspects (e.g. single or combined interventions measure, population studied, severity of respiratory symptoms, outcomes, evaluated parameters, etc.), it is important to outline that a successful approach requires that the avoided allergen is the only and real factor responsible for symptoms, the patient's education and the use of a comprehensive protocol to reduce allergen exposure. Other important factors include the involvement of the patient, the relevance of other allergens/non-specific agents, and exposure to sensitizing agents also outside patient's home. It is likely that the clinical phase of allergic airway disease and the degree of bronchial (and also nasal) remodelling, in each individual, represent relevant factors for the clinical outcome of allergen avoidance procedures. Since the management of respiratory allergy is a complex strategy (including drugs, allergen avoidance, immunological and educational interventions), it is difficult in real life to distinguish the efficacy of a single intervention in comparison to the others. A combined strategy is likely to produce better clinical results.
Collapse
Affiliation(s)
- Gennaro Liccardi
- Department of Chest Diseases. Division of Pneumology and Allergology A. Cardarelli Hospital, Rione Sirignano, no. 10, 80121, Naples Italy
| | | | | | | | | |
Collapse
|
18
|
Richardson G, Eick S, Jones R. How is the indoor environment related to asthma?: literature review. J Adv Nurs 2006; 52:328-39. [PMID: 16194186 DOI: 10.1111/j.1365-2648.2005.03591.x] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
AIMS This paper reports a review conducted to identify the factors in the indoor environment that have an evidence-based link with the exacerbation or development of asthma and to identify measures that healthcare professionals can promote to reduce exposure to these risk factors in the home. BACKGROUND The indoor environment, particularly at home, has been recognized as a major source of exposure to allergens and toxic chemicals. Exposure to allergens and toxins is thought to exacerbate respiratory conditions, in particular, asthma. METHODS Searches were made of health and indoor environment databases, including Cochrane Library, National Health Services Centre for Reviews and Assessment Reports, British Medical Journal, CINAHL and Ovid library, MEDSCAPE/MEDLINE, EMBASE, INGENTA, Science Citation Index, Web of Science. Searches were also made of other Internet-based resources, including those of international and government bodies. The following keywords were used: allergens, allergen avoidance, asthma, asthma prevention, cat, damp, Der p 1, dog, environmental control, house dust mites, indoor air quality, indoor environment, meta analysis, mould, pets, remedial actions, respiratory illnesses and systematic reviews. FINDINGS There is evidence of a link between asthma and a small number of indoor environmental factors. There is currently only reasonable evidence for one causative factor for asthma in the indoor environment and that is house dust mite allergen. Although there are many studies of different remedial actions that can be taken in the home, often these give evidence of reduced risk of exposure but not clinical improvement in asthma. Although there is a lack of medical evidence for the reduction of known sensitizers such as mould, this is because of a dearth of research rather than evidence of no association. CONCLUSIONS There is some evidence of a link between the indoor environment and asthma. There are measures, which could be promoted by healthcare professionals to alleviate asthmatic symptoms.
Collapse
Affiliation(s)
- George Richardson
- Faculty of Health and Social Work, University of Plymouth, Plymouth, UK.
| | | | | |
Collapse
|
19
|
Terreehorst I, Duivenvoorden HJ, Tempels-Pavlica Z, Oosting AJ, de Monchy JGR, Bruijnzeel-Koomen CAFM, van Wijk RG. The effect of encasings on quality of life in adult house dust mite allergic patients with rhinitis, asthma and/or atopic dermatitis. Allergy 2005; 60:888-93. [PMID: 15932378 DOI: 10.1111/j.1398-9995.2004.00677.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Environmental control has been put forward as an integral part of the management of house dust mite (HDM) allergy in sensitized patients. To validate this statement allergic disorders involved in HDM allergy--allergic asthma, rhinitis and atopic eczema/dermatitis syndrome (AEDS)--should be taken together and studied in terms of the efficacy of environmental control. Because a generic quality of life questionnaire exceeds the border of disease, this may be used as major outcome parameter. RESEARCH OBJECTIVE To study the effects of bedding encasings in HDM allergic patients with asthma, rhinitis and AEDS. MATERIAL AND METHODS A total of 224 adult HDM allergic patients with rhinitis and/or asthma and/or dermatitis were randomly allocated impermeable or nonimpermeable encasings for mattress, pillow and duvet. Short form 36 (SF-36) was filled in at baseline and after 12 months. RESULTS Lower physical (P = 0.01) and emotional (P < 0.001) sumscores were seen in females. Also, the presence of asthma resulted in lower physical sumscore (P = 0.01). However, no effect was seen of encasings on either sumscore. CONCLUSION Bedding encasings do not improve quality of life in a mixed population of subjects with combinations with rhinitis, asthma and atopic dermatitis and sensitized to HDMs.
Collapse
Affiliation(s)
- I Terreehorst
- Department of Allergology, Erasmus Medical Centre Rotterdam, Rotterdam, the Netherlands
| | | | | | | | | | | | | |
Collapse
|
20
|
Abstract
BACKGROUND The major allergen in house dust comes from mites. Chemical, physical and combined methods of reducing mite allergen levels are intended to reduce asthma symptoms in people who are sensitive to house dust mites. OBJECTIVES To assess the effects of reducing exposure to house dust mite antigens in the homes of people with mite-sensitive asthma. SEARCH STRATEGY Cochrane Airways Group trials register, and PubMed and The Cochrane Library (last searches June 2004), reference lists. SELECTION CRITERIA Randomised trials of mite control measures vs placebo or no treatment in asthmatic people known to be sensitive to house dust mites. DATA COLLECTION AND ANALYSIS Two reviewers applied the trial inclusion criteria, assessed their quality and extracted the data independently. Study authors were contacted to clarify information. MAIN RESULTS Forty-nine trials (2733 patients) were included; the number of patients has more than doubled since the last version of this review. Thirty-one trials assessed physical methods, ten assessed chemical methods, and eight a combination of chemical and physical methods. Despite the fact that many trials were of poor quality and would be expected to exaggerate the reported effect, we did not find an effect of the interventions. For the most frequently reported outcome, peak flow in the morning (1339 patients), the standardised mean difference was -0.02 (95% confidence interval (CI) -0.13 to 0.08). There were no statistically significant differences either in number of patients improved (relative risk 1.01, 95% CI 0.80 to 1.27), asthma symptom scores (standardised mean difference -0.01, 95% CI -0.10 to 0.13), or in medication usage (standardised mean difference -0.05, 95% CI -0.18 to 0.09). REVIEWERS' CONCLUSIONS Chemical and physical methods aimed at reducing exposure to house dust mite allergens cannot be recommended. It is doubtful whether further studies, similar to the ones in our meta-analysis, are worthwhile. If other types of studies are considered, they should be methodologically rigorous and use other methods than those used so far, with careful monitoring of mite exposure and relevant clinical outcomes.
Collapse
Affiliation(s)
- P C Gøtzsche
- Nordic Cochrane Centre, Rigshospitalet, Dept. 7112, Blegdamsvej 9, Copenhagen Ø, Denmark, 2100
| | | | | | | |
Collapse
|
21
|
Bornehag CG, Sundell J, Bonini S, Custovic A, Malmberg P, Skerfving S, Sigsgaard T, Verhoeff A. Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness and mite exposure in buildings and health effects. INDOOR AIR 2004; 14:243-57. [PMID: 15217478 DOI: 10.1111/j.1600-0668.2004.00240.x] [Citation(s) in RCA: 87] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
UNLABELLED The scientific literature on health effects from dampness in buildings, including mite exposure over the period 1998-2000 has been reviewed by an European group (EUROEXPO) of eight scientists in experience from medicine, epidemiology, toxicology and engineering. Forty studies deemed relevant have been the foundation for the conclusions. Dampness in buildings is a risk factor for health effects among atopics and non-atopics both in domestic and in public environments. However, the literature is not conclusive in respect of causative agents, e.g. mites, microbiological agents and organic chemicals from degraded building materials. There is a strong need for more multidisciplinary studies including expertise from all relevant areas. A general conclusion from the work was that there is a strong need for multidisciplinary reviews in scientific journals of articles dealing with associations between indoor environmental factors and health effects. PRACTICAL IMPLICATIONS There is good evidence for a true association between dampness in buildings and health. As the causative factors behind this association are not known, the main focus in practical investigations should be on finding out and remediate the reasons for the humidity problem.
Collapse
Affiliation(s)
- C G Bornehag
- Swedish National Testing and Research Institute, Boras, Sweden.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Recer GM. A review of the effects of impermeable bedding encasements on dust-mite allergen exposure and bronchial hyper-responsiveness in dust-mite-sensitized patients. Clin Exp Allergy 2004; 34:268-75. [PMID: 14987307 DOI: 10.1111/j.1365-2222.2004.01863.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Sensitization and exposure to dust-mite antigens are causative factors in the development and exacerbation of asthma. Impermeable bedding encasements are considered a first-line treatment to reduce dust-mite antigen exposure in clinical asthma-management guidelines. Public-health recommendations for environmental asthma treatments should be based on the weight of evidence supporting the reliability of environmental interventions so that uncertainties regarding their effectiveness can be accurately communicated to patients, and so that limited public-health resources can be most effectively utilized. OBJECTIVE To evaluate the strength of a clinical-trial evidence supporting the efficacy of bedding encasements as an asthma treatment. METHODS A narrative review was conducted of all clinical trials involving bedding encasement for the treatment of asthma. Collective statistical analyses were also performed to characterize the quantitative effect of bedding encasement on dust-mite allergen exposure and bronchial hyper-responsiveness (BHR) when used by asthma patients. RESULTS Over 30 clinical trials were reviewed. Of those studies reporting adequate exposure and BHR results, four reported significant reduction in dust-mite allergen exposure and concomitant BHR reduction in active-treatment groups using bedding encasements. In 10 studies, mite-allergen exposure was reportedly decreased during the study, but BHR was not changed in the active-treatment group or was reduced to a similar degree in the active-treatment and control groups. Five other studies reported a lack of significant effect of the intervention on exposure and BHR. Collective paired analyses found that the effect of bedding encasement on allergen exposure and BHR tended toward only a modest, non-significant improvement. Collectively, effects of bedding encasement on BHR and dust-mite allergen exposure were modestly correlated only when the baseline exposure was above 2 microg Type 1 antigen per gram settled dust. CONCLUSION Although bedding encasement might be an effective asthma treatment under some conditions, when implemented in clinical trials by asthma patients, its effectiveness is inconsistent and appears to be, at best, modest. Therefore, its significance as a reliable asthma management modality for any individual asthma patient is uncertain. Where resource constraints are significant, targeting the use of variably effective interventions such as bedding encasements toward those patient sub-populations most likely to derive substantial benefit may gain the largest net public-health benefit.
Collapse
Affiliation(s)
- G M Recer
- New York State Department of Health, Center for Environmental Health, Troy, NY 12180, USA.
| |
Collapse
|
23
|
Rijssenbeek-Nouwens LHM, Oosting AJ, Bruijnzeel-Koomen CAFM, de Bruin-Weller MS. Anti-allergic mattress covers in asthma: to do or not to do? Clin Exp Allergy 2004; 33:1613-7. [PMID: 14656344 DOI: 10.1111/j.1365-2222.2003.01829.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
24
|
Terreehorst I, Hak E, Oosting AJ, Tempels-Pavlica Z, de Monchy JGR, Bruijnzeel-Koomen CAFM, Aalberse RC, Gerth van Wijk R. Evaluation of impermeable covers for bedding in patients with allergic rhinitis. N Engl J Med 2003; 349:237-46. [PMID: 12867607 DOI: 10.1056/nejmoa023171] [Citation(s) in RCA: 162] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Encasing bedding in impermeable covers reduces exposure to house-dust mites, but the clinical benefit of this intervention as part of mite-avoidance measures for patients with allergic rhinitis is not known. We performed a multicenter, randomized, placebo-controlled trial of one year of use of impermeable bedding covers in the bedrooms of patients with rhinitis who were sensitized to house-dust mites to determine the effects on the signs and symptoms of disease. METHODS Three participating university medical centers enrolled 279 patients with allergic rhinitis who were randomly assigned to receive impermeable or non-impermeable (control) covers for their mattress, pillow, and duvet or blanket. At the start of the study, all participants received information on general allergen-avoidance measures. The severity of rhinitis was measured on a rhinitis-specific visual-analogue scale and by means of a daily symptom score and nasal allergen provocation testing. We also measured the concentrations of Dermatophagoides pteronyssinus (Der p1) and D. farinae (Der f1) in dust from patients' mattresses, bedroom floors, and living-room floors at base line and after 12 months as a measure of the efficacy of the intervention. RESULTS A total of 232 patients completed the study. There was a significant reduction in Der p1 and Der f1 concentrations in the mattresses of the impermeable-cover group, whereas there was no significant reduction in the control group. However, there was no significant effect on the clinical outcome measures. Analyses of subgroups defined according to age, level of exposure, type and severity of sensitization, or characteristics of the patient's home had similar results. CONCLUSIONS Mite-proof bedding covers, as part of a structured allergy-control program, reduced the level of exposure to mite allergens. Despite the success of the intervention, this single avoidance measure did not lead to a significant improvement of clinical symptoms in patients with allergic rhinitis.
Collapse
Affiliation(s)
- Ingrid Terreehorst
- Department of Allergology, Erasmus Medical Center, Rotterdam, Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Woodcock A, Forster L, Matthews E, Martin J, Letley L, Vickers M, Britton J, Strachan D, Howarth P, Altmann D, Frost C, Custovic A. Control of exposure to mite allergen and allergen-impermeable bed covers for adults with asthma. N Engl J Med 2003; 349:225-36. [PMID: 12867606 DOI: 10.1056/nejmoa023175] [Citation(s) in RCA: 184] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND The effectiveness of avoidance of house-dust-mite allergen (Dermatophagoides pteronyssinus 1 [Der p1]) in the management of asthma is uncertain. METHODS We conducted a double-blind, randomized, placebo-controlled study of allergen-impermeable bed covers involving 1122 adults with asthma. The primary outcomes were the mean morning peak expiratory flow rate over a four-week period during the run-in phase and at six months and the proportion of patients who discontinued inhaled corticosteroid therapy as part of a phased-reduction program during months 7 through 12. Der p1 was measured in mattress dust in a 10 percent random subsample of homes at entry and at 6 and 12 months. RESULTS The prevalence of sensitivity to dust-mite allergen was 65.4 percent in the group supplied with allergen-impermeable bed covers (active-intervention group) and 65.1 percent in the control group supplied with non-impermeable bed covers. The concentration of Der p1 in mattress dust was significantly lower in the active-intervention group at 6 months (geometric mean, 0.58 microg per gram vs. 1.71 microg per gram in the control group; P=0.01) but not at 12 months (1.05 microg per gram vs. 1.64 microg per gram; P=0.74). The mean morning peak expiratory flow rate improved significantly in both groups (from 410.7 to 419.1 liters per minute in the active-intervention group, P<0.001 for the change; and from 417.8 to 427.4 liters per minute in the control group, P<0.001 for the change). After adjustment for base-line differences (by analysis of covariance), there was no significant difference between the groups in the peak expiratory flow rate at six months (difference in means, active-intervention group vs. control group, -1.6 liters per minute [95 percent confidence interval, -5.9 to 2.7] among all patients [P=0.46] and -1.5 liters per minute [95 percent confidence interval, -6.9 to 3.9] among mite-sensitive patients [P=0.59]). There was no significant difference between the groups in the proportion in whom complete cessation of inhaled corticosteroid therapy was achieved (17.4 percent in the active-intervention group and 17.1 percent in the control group) or in the mean reduction in steroid dose, either among all patients or among mite-sensitive patients. CONCLUSIONS Allergen-impermeable covers, as a single intervention for the avoidance of exposure to dust-mite allergen, seem clinically ineffective in adults with asthma.
Collapse
Affiliation(s)
- Ashley Woodcock
- South Manchester Academic Group, University of Manchester, North West Lung Centre, Wythenshawe Hospital, Manchester, United Kingdom.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Høst A, Andrae S, Charkin S, Diaz-Vázquez C, Dreborg S, Eigenmann PA, Friedrichs F, Grinsted P, Lack G, Meylan G, Miglioranzi P, Muraro A, Nieto A, Niggemann B, Pascual C, Pouech MG, Rancé F, Rietschel E, Wickman M. Allergy testing in children: why, who, when and how? Allergy 2003; 58:559-69. [PMID: 12823111 DOI: 10.1034/j.1398-9995.2003.00238.x] [Citation(s) in RCA: 140] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
27
|
Boner A, Pescollderungg L, Silverman M. The role of house dust mite elimination in the management of childhood asthma: an unresolved issue. Allergy 2003; 57 Suppl 74:23-31. [PMID: 12371910 DOI: 10.1034/j.1398-9995.57.s74.5.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Indoor allergens are likely to be direct environmental causes of asthma and mite exposure, and sensitization is the most important environmental risk factor for childhood asthma in temperate zones. Analagous to occupational asthma, allergen avoidance in asthmatic children sensitized and exposed to mite allergens is associated with a reduction in airway hyperresponsiveness and symptoms associated with improvement in lung function. The long-term effect of this strategy needs to be prospectively evaluated considering both the timing and duration of exposure, as well as the timing and duration of removal. In order to be successful, it is important to achieve and maintain a major reduction on allergen levels, for a long period of time.
Collapse
Affiliation(s)
- A Boner
- Department of Pediatrics, University of Verona, Italy
| | | | | |
Collapse
|
28
|
Arbes SJ, Cohn RD, Yin M, Muilenberg ML, Burge HA, Friedman W, Zeldin DC. House dust mite allergen in US beds: results from the First National Survey of Lead and Allergens in Housing. J Allergy Clin Immunol 2003; 111:408-14. [PMID: 12589364 DOI: 10.1067/mai.2003.16] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Although exposure to house dust mite allergen is a major risk factor for allergic sensitization and asthma, nationwide estimates of dust mite allergen levels in US homes have not been reported. OBJECTIVE The purpose of this study was to estimate the prevalence of dust mite allergen in beds of US homes and to identify predictors of dust mite allergen concentration. METHODS Data were obtained from the first National Survey of Lead and Allergens in Housing, a cross-sectional survey of 831 permanently occupied noninstitutional housing units that permitted resident children. Dust mite allergen concentration (Der f 1 plus Der p 1) was determined from a dust sample collected from a bed. The percentages of homes with concentrations at or greater than detection, 2.0 microg/g bed dust, and 10.0 microg/g bed dust were estimated. Independent predictors of allergen concentration were assessed with multivariable linear regression. RESULTS The percentages of US homes with dust mite allergen concentrations at or greater than detection, 2.0 microg/g, and 10.0 microg/g were 84.2% (SE, 1.73), 46.2% (SE, 2.0), and 24.2% (SE, 2.1), respectively. Independent predictors of higher levels were older homes, non-West census regions, single-family homes, no resident children, lower household income, heating sources other than forced air, musty or mildew odor, and higher bedroom humidity. CONCLUSION Most US homes have detectable levels of dust mite allergen in a bed. Levels previously associated with allergic sensitization and asthma are common in US bedrooms. Predictors can be used to identify conditions under which homes are more likely to have increased dust mite allergen levels.
Collapse
Affiliation(s)
- Samuel J Arbes
- Division of Intramural Research, National Institute of Environmental Health Sciences/NIH, 111 Alexander Drive, Research Triangle Park, NC 27709, USA
| | | | | | | | | | | | | |
Collapse
|
29
|
Halken S, Høst A, Niklassen U, Hansen LG, Nielsen F, Pedersen S, Osterballe O, Veggerby C, Poulsen LK. Effect of mattress and pillow encasings on children with asthma and house dust mite allergy. J Allergy Clin Immunol 2003; 111:169-76. [PMID: 12532114 DOI: 10.1067/mai.2003.5] [Citation(s) in RCA: 117] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND House dust mite (HDM) allergy is a frequent cause of allergic asthma in children. Reduction of exposure seems to be the most logical way to treat these patients. OBJECTIVE Our aim was to investigate whether mattress and pillow encasings resulted in an effective long-term control of HDM allergen levels, thereby reducing the need for asthma medication in children with asthma and HDM allergy. METHODS In a prospective, double-blind, placebo-controlled study 60 children (age range, 6-15 years) with asthma and HDM allergy were randomized to active (allergy control) or placebo mattress and pillow encasings. After a 2-week baseline period, follow-up was performed every 3 months for 1 year. During the entire study period, the dose of inhaled steroids was tapered off to the lowest effective dose according to well-defined criteria. RESULTS Fifty-two patients completed the trial, and 5 were excluded, leaving data from 47 children (26 in the active treatment group and 21 in the placebo group) for analysis. A significant perennial reduction in HDM allergen concentrations was seen only for the active treatment group. Also, a significant decrease in the dose of inhaled steroids (mean, 408 to 227 microg/d; P <.001) was found for the active treatment group only, with significant differences between groups after 9 and 12 months. After 1 year, the dose of inhaled steroids was reduced by at least 50% in significantly more children in the active treatment group than in the placebo group (73% vs 24%, P <.01). CONCLUSION Encasing of mattresses and pillows resulted in a significant long-term reduction in HDM allergen concentrations in mattresses and in the need for inhaled steroids in children with asthma and HDM allergy.
Collapse
Affiliation(s)
- Susanne Halken
- Department of Pediatrics, Sønderborg Hospital, Sønderborg, Denmark
| | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
BACKGROUND Asthma is a common respiratory disease among both adults and children and short acting inhaled beta-2 agonists are used widely for 'reliever' bronchodilator therapy. Long acting beta-2 agonists were introduced as prospective 'symptom controllers' in addition to inhaled corticosteroid 'preventer' therapy (ICS). OBJECTIVES This review aimed to determine the benefit or detriment on the primary outcome of asthma control with the regular use of long acting inhaled beta-2 agonists compared with placebo. SEARCH STRATEGY We carried out searches using the Cochrane Airways Group trial register, most recently in October 2002. We searched bibliographies of identified RCTs for additional relevant RCTs and contacted authors of identified RCTs for other published and unpublished studies. SELECTION CRITERIA All randomised studies of at least two weeks duration, comparing a long acting inhaled beta-agonist given twice daily with a placebo, in chronic asthma. DATA COLLECTION AND ANALYSIS Two reviewers performed data extraction and study quality assessment independently. We contacted authors of studies for missing data. MAIN RESULTS Eighty five studies met the inclusion criteria, 56 parallel group and 29 cross over design. Salmeterol xinafoate was used as long acting agent in 60 studies and formoterol fumarate in 25. The treatment period was two to four weeks in 32 studies, and 12 to 52 weeks in 53 studies. 34 study groups used concurrent inhaled corticosteroid treatment, 21 studies did not permit their use and 35 permitted either inhaled corticosteroid or cromones. There were significant advantages to long acting beta-2 agonist treatment compared to placebo for a variety of measurements of airway calibre including morning peak expiratory flow (PEF) (weighted mean difference (WMD) 26.78 L/min 95%CI 20.36 to 33.20), evening PEF (WMD 19.17 L/min 95%CI 11.63 to 26.73). They were associated with significantly fewer symptoms, less use of rescue medication and higher quality of life scores. The risk of exacerbation was lower in adults using regular inhaled corticosteroids. REVIEWER'S CONCLUSIONS Long acting beta-2 agonists are effective in the control of chronic asthma, and the evidence supports their use in addition to inhaled corticosteroids, as emphasised in current guidelines. Further research is needed on their use in children under 12 and in mild asthmatics not taking ICS.
Collapse
Affiliation(s)
- E H Walters
- Discipline of Medicine, University of Tasmania Medical School, 43 , Collins Street, PO BOX 252-34, Hobart, 7001, Tasmania, Australia. Haydn.Walters @utas.edu.au
| | | | | |
Collapse
|
31
|
|
32
|
Oosting AJ, de Bruin-Weller MS, Terreehorst I, Tempels-Pavlica Z, Aalberse RC, de Monchy JGR, van Wijk RG, Bruijnzeel-Koomen CAFM. Effect of mattress encasings on atopic dermatitis outcome measures in a double-blind, placebo-controlled study: the Dutch mite avoidance study. J Allergy Clin Immunol 2002; 110:500-6. [PMID: 12209102 DOI: 10.1067/mai.2002.126791] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND House dust mite (HDM) allergen might induce and maintain atopic dermatitis (AD). Reduction of allergen load by applying encasings might improve the clinical symptoms of AD. OBJECTIVE We sought to investigate, in a randomized, double-blind, placebo-controlled study, whether reducing HDM allergen levels by using mattress, duvet, and pillow encasings for 12 months will result in improvement in AD symptoms. METHODS Patients with AD (8-50 years old and allergic to HDM), having a Leicester sign score (a dermatitis score) of at least 1% extent and a severity score of 6 points or greater, were randomly allocated to an active (n = 45) or a placebo allergen-avoidance group (n = 41). Avoidance measures consisted of applying HDM-impermeable encasings for mattresses, pillows, and duvets for the active treatment group and cotton encasings for the placebo group. Effect on allergen concentrations (Der p 1 and Der p 1 plus Der f 1), Leicester sign score extent and severity, visual analogue scale scores for itching and sleeplessness, intradermal test results, atopy patch test results, total serum IgE levels, anti-Der p 1-specific IgE levels, and total blood eosinophil counts were studied. RESULTS The active encasings reduced the Der p 1 allergen concentration in the mattress after 12 months with a factor 2.1 (P =.007) and the Der p 1 plus Der f 1 allergen concentration with a factor of 2.5 (P =.005); no significant change in allergen concentrations in mattresses was seen in the placebo group. Although the decrease in allergen load was significant, no differences in treatment-induced changes were seen between the placebo and active groups. CONCLUSIONS Use of HDM-impermeable encasings resulted in a significant decrease in Der p 1 and Der p 1 plus Der f 1 allergen concentrations. However, this reduction in allergen load did not result in significant changes in clinical parameters between the groups. Reduction of allergens in other environments (work, school, and outdoors) might be equally important in improving symptoms of AD.
Collapse
Affiliation(s)
- Albert-Jan Oosting
- Department of Dermatology and Allergology, University Medical Centre Utrecht, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Rijssenbeek-Nouwens LHM, Oosting AJ, de Bruin-Weller MS, Bregman I, de Monchy JGR, Postma DS. Clinical evaluation of the effect of anti-allergic mattress covers in patients with moderate to severe asthma and house dust mite allergy: a randomised double blind placebo controlled study. Thorax 2002; 57:784-90. [PMID: 12200523 PMCID: PMC1746424 DOI: 10.1136/thorax.57.9.784] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND The use of anti-allergic mattress covers in patients with asthma can result in a large reduction in the level of house dust mite allergen in dust samples. Apart from a reduction in histamine induced bronchial hyperresponsiveness, there are few data on the effect of mattress covers on clinical efficacy and quality of life in patients with moderate to severe asthma. METHODS Thirty patients with asthma and house dust mite allergy were studied in a randomised, double blind, placebo controlled study. Before and after using anti-allergic covers for 1 year, dust was collected from the mattresses to determine concentrations of Dermatophagoides pteronyssinus (Der p 1), and bronchial hyperresponsiveness and quality of life were measured. The patients scored their symptoms (lungs and nose), morning and evening peak flow values, and rescue medication for 14 days before and after the intervention period. RESULTS There was a significant reduction in the concentration of Der p 1 in the dust collected from the mattresses in the actively treated group after 1 year compared with before treatment; no change was found in the placebo group. In both the actively treated and placebo groups there was no significant improvement in PC(20) histamine. Quality of life improved similarly in both groups. The symptom score of the lower airways did not significantly change in either group. A significant decrease in nasal symptom score was seen in the actively treated group compared with before treatment, but there was no significant difference between the groups. No changes in morning and evening peak flow values, peak flow variability, nor in the use of rescue medication were found in either group. CONCLUSION The use of anti-allergic mattress covers results in significant reductions in Der p 1 concentrations in carpet-free bedrooms. However, in patients with moderate to severe asthma, airways hyperresponsiveness and clinical parameters are not affected by this effective allergen avoidance.
Collapse
|
34
|
Custovic A, Murray CS, Gore RB, Woodcock A. Controlling indoor allergens. Ann Allergy Asthma Immunol 2002; 88:432-41; quiz 442-3, 529. [PMID: 12027062 DOI: 10.1016/s1081-1206(10)62378-2] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Reading of this article reinforces the reader's knowledge of the role of allergen exposure in relation to asthma and its severity, as well as the relevance of allergen avoidance in the treatment of asthma. DATA SOURCES Initial literature search for existing evidence-based guidelines, reviews, and meta-analyses was carried out, and further literature searches were performed to review individual randomized controlled trials. Evidence level was graded according to the Scottish Intercollegiate Guidelines Network recommendations. RESULTS There is good evidence for the link between mite and cockroach allergen exposure and sensitization, and between sensitization and asthma. For pet allergens, some studies found that exposure to pets in early life was associated with specific immunoglobulin E sensitization and allergic disease later in childhood, whereas others reported a protective effect. The effectiveness of allergen reduction in the treatment of asthma is suggested by studies in which the patients improve substantially when moved into the low-allergen environment of hospitals or high-altitude sanatoria. Because of limitations in the design of the most clinical of studies, we do not yet have a conclusive answer on the effectiveness of domestic aeroallergen avoidance. CONCLUSIONS Minimizing the impact of identified environmental risk factors is an important first step to reduce the severity of asthma. Although environmental control is difficult, it should be an integral part of the overall management of sensitized patients. However, what is unclear is which patients would benefit and by how much, and whether the intervention is cost-effective. These questions will be answered satisfactorily only by large randomized trials.
Collapse
Affiliation(s)
- Adnan Custovic
- North West Lung Centre, Wythenshawe Hospital, Manchester, United Kingdom.
| | | | | | | |
Collapse
|
35
|
Høst A, Halken S. Can we apply clinical studies to real life? Evidence-based recommendations from studies on development of allergic diseases and allergy prevention. Allergy 2002; 57:389-97. [PMID: 11972477 DOI: 10.1034/j.1398-9995.2002.00154.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Arne Høst
- Department of Pediatrics, Odense University Hospital, DK-5000 Odense C, Denmark
| | | |
Collapse
|
36
|
Bijl-Hofland ID, Cloosterman SG, Folgering HT, van den Elshout FJ, van Weel C, van Schayck CP. Inhaled corticosteroids, combined with long-acting beta(2)-agonists, improve the perception of bronchoconstriction in asthma. Am J Respir Crit Care Med 2001; 164:764-9. [PMID: 11549530 DOI: 10.1164/ajrccm.164.5.9910103] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
The relationship between asthma medication and the perception of asthma symptoms is of interest for daily practice. Poor perception of asthma symptoms might influence patients' health care behavior and subsequently might lead to undertreatment and deterioration of their disease. This study investigated the influence of the chronic use of short-acting and long-acting beta(2)-agonists, compared with the additional use of inhaled corticosteroids on the perception of histamine-induced bronchoconstriction. Patients with asthma (33 male and 31 female, mean age 35 +/- 11 yr, FEV(1) 87 +/- 14% of the reference value, PC(20) geometric mean 1.08 mg/ml (95% CI: 0.76-1.52) were selected and randomly allocated to the use of either a short-acting beta(2)-agonists (salbutamol, n = 22) or a long-acting beta(2)-agonists (formoterol, n = 22) or placebo (n = 20), which has been used for 12 wk. This medication treatment was repeated exactly 1 yr later, with patients receiving the same medication plus an inhaled corticosteroid. Perception of histamine-induced bronchoconstriction was measured at the start of each treatment period and every 4 wk thereafter. Subjects quantified their sensation of respiratory discomfort during the challenge tests on a modified Borg scale. The perceptive "sensitivity" for changes in FEV(1) was analyzed by the linear regression slope (alpha) "Borg versus percentage fall in FEV(1)." The "absolute perceptual magnitude" was determined by the perception score at the 20% fall in FEV(1) (PS(20)). The additional use of inhaled corticosteroids during the second year resulted in an improved perception of histamine-induced bronchoconstriction (slope alpha) compared with the first year for only the long-acting beta(2)-agonists group (p value 0.036). This improvement was not observed for the "absolute perceptual magnitude" (PS(20)). The additional use of inhaled corticosteroids during chronic use of long-acting beta(2)-agonists improves the perceptive "sensitivity" for changes in FEV(1) during histamine-induced bronchoconstriction, which was not observed for short-acting bronchodilators. This result might indicate that the positive effects on perception of airway obstruction might be another reason (besides the beneficial effects on the clinical condition) for prescribing a combination of long-acting beta(2)-agonists and inhaled steroids.
Collapse
Affiliation(s)
- I D Bijl-Hofland
- Department of General Practice and Social Medicine, Dekkerswald, University of Nijmegen, The Netherlands.
| | | | | | | | | | | |
Collapse
|
37
|
Cloosterman SG, Bijl-Hofland ID, van Herwaarden CL, Akkermans RP, van Den Elshout FJ, Folgering HT, van Schayck CP. A placebo-controlled clinical trial of regular monotherapy with short-acting and long-acting beta(2)-agonists in allergic asthmatic patients. Chest 2001; 119:1306-15. [PMID: 11348933 DOI: 10.1378/chest.119.5.1306] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND Some recent studies suggest that regular beta(2)-agonist use may result in inadequate control of asthma. It has been hypothesized that this occurs particularly in allergic asthmatic patients exposed to relevant allergens. Moreover, it is still unclear whether this occurs during the use of both short-acting and long-acting beta(2)-agonists. METHODS Asthmatic patients (n = 145) allergic to house dust mite (HDM) were randomly allocated to monotherapy with a short-acting beta(2)-agonist (SA; n = 48), a long-acting beta(2)-agonist (LA; n = 50), or placebo (n = 47), double blind, double dummy. The study covered three periods: (1) a 4-week run-in period, in which no changes took place; followed by (2) cessation of treatment with asthma medication including inhaled corticosteroids, introduction of allergen avoidance measures (active/placebo treatment) to lower HDM exposure in the active group, and an 8-week washout period to adjust patients to these changes; followed by (3) a 12-week study medication period. At the start of the 12-week medication period, and every 4 weeks thereafter, spirometric measurements (FEV(1) and provocative concentration of histamine causing a 20% fall in FEV(1) [PC(20)]) were performed. Peak flow and asthma symptoms were recorded daily. Additionally, at the start and every 6 weeks thereafter, dust samples were collected from mattresses and living room and bedroom floors to assess HDM (der p 1) concentrations. Effects on FEV(1), PC(20), peak flow, and asthma symptoms were analyzed with repeated-measurement analysis and corrected for the exposure to HDM allergens. RESULTS There were no significant differences among the three medication groups after 12 weeks for FEV(1). However, a significant decrease in mean FEV(1) percent predicted (95% confidence interval [CI]) was observed within the SA group: - 6.6 (- 10.4 to - 2.8) (p = 0.0002). A decrease in geometric mean PC(20) (95% CI) of - 1.2 (- 1.96 to - 0.44) doubling concentration was observed within the SA group (p = 0.05). No significant changes in FEV(1) and PC(20) were observed > 12 weeks within the LA group or the placebo group. There were neither changes in peak flow and asthma symptom scores among the three medication groups nor within the groups. Moreover, none of the parameters showed interactive effects with allergen exposure. CONCLUSION There were no significant differences among the three medication groups for FEV(1) and PC(20). The within-treatment group comparison showed a significant small decline in FEV(1) for the SA group (but not for the LA group), which could indicate that monotherapy with SAs might have negative effects on FEV(1). This was not seen during regular use of LAS: No clear pathophysiologic mechanism can explain these findings at the moment. Relatively high or low exposure to allergens did not alter these findings.
Collapse
Affiliation(s)
- S G Cloosterman
- Department of General Practice and Social Medicine, University of Nijmegen, Nijmegen, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
38
|
Affiliation(s)
- J A Warner
- Division of Allergy and Inflammation Sciences (Child Health), Southampton General Hospital, UK.
| |
Collapse
|
39
|
Walters EH, Walters J. Inhaled short acting beta2-agonist use in asthma: regular vs as needed treatment. Cochrane Database Syst Rev 2000; 2003:CD001285. [PMID: 11034709 PMCID: PMC8407398 DOI: 10.1002/14651858.cd001285] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Inhaled beta2-adrenergic agonists delivered by inhalation are very widely used in asthma. There has been much controversy of the use and possible consequences of the use of these agents for regular, as opposed as-needed use in asthma. OBJECTIVES This review to assessed the clinical trial evidence to test whether using regular use of short-acting beta2-agonists reduced asthma control and pulmonary function; worsened symptoms, airway reactivity and quality of life; and increased the rate of exacerbations. SEARCH STRATEGY A search was carried out of the Cochrane Airways Group "Asthma and Wheez* RCT" register using the terms: regular AND [beta agonist OR bronchodilator OR salbutamol OR albuterol Or terbutaline OR isoproterenol OR reproterol OR fenoterol]. Bibliographies of existing trials were searched and primary trial authors and pharmaceutical companies were approached for additional trials. SELECTION CRITERIA Randomised controlled trials in which the short-acting beta2-agonist was given regularly in the experimental group, together with an inhaled bronchodilator for relief of symptoms ('rescue use'). The control group consisted of matching placebo inhaled regularly, with an inhaled bronchodilator for as-needed 'rescue use'. DATA COLLECTION AND ANALYSIS Data were extracted and quality assessments were made by both reviewers. Parallel group and cross-over trials were analysed separately. Where possible data were pooled using a fixed effects model. MAIN RESULTS Over 800 abstracts were identified, following a review, 60 papers were requested for full assessment by both reviewers. 34 trials from 30 papers met the entry criteria. Data from 31 outcomes were analyzable. There was little difference between the treatments for nearly all outcomes. In cross-over studies, evening peak flow was better with regular treatment, weighted mean difference (WMD) 13.1 l/min (95% confidence interval 24.3, 1.9). In contrast, the FEV1 was better with as-needed treatment (WMD 157 ml (95% CI: 123, 192). Bronchial hyper reactivity was slightly better in the as-needed group, standardised mean difference 0.23, 95% CI: 0.52, 1.12. REVIEWER'S CONCLUSIONS These results support current guidelines. There is little advantage in using short-acting beta2-agonists regularly, and potentially some small clinical disadvantage.
Collapse
Affiliation(s)
- E H Walters
- Department of Respiratory Medicine, Alfred Hospital, Commercial Road, Prahan, Victoria, Australia.
| | | |
Collapse
|