1
|
Hauser A, Meixenberger K, Machnowska P, Fiedler S, Hanke K, Hofmann A, Bartmeyer B, Bremer V, Bannert N, Kuecherer C. Robust and sensitive subtype-generic HIV-1 pol genotyping for use with dried serum spots in epidemiological studies. J Virol Methods 2018; 259:32-38. [PMID: 29859195 DOI: 10.1016/j.jviromet.2018.05.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 05/23/2018] [Accepted: 05/29/2018] [Indexed: 10/14/2022]
Abstract
HIV-1 genotyping of larger pol-fragments from dried serum/plasma spots (DSS/DPS) is often hindered by RNA-degradation during transportation at ambient temperature. We evaluated an in-house HIV-1 DSS/DPS-genotyping assay designed in two shorter overlapping fragments covering all resistance mutations in protease and reverse transcriptase. Validation criteria such as specificity, detection limit, accuracy, reproducibility and storage conditions were assessed using reference plasma samples prepared as DPS and clinical DSS from the German molecular HIV-1 surveillance processed under real-life transportation conditions. The specificity was 100% for both samples types, and the experimental DPS detection limit of 1000 copies/ml yielded a 98.7% (3,329/3373) success rate for DSS (including all subtypes) above this detection limit. Accuracy for DPS compared to the gold standard was 99.1% and the reproducibility was 100% for DPS replicates and 99.9% for DSS pairs. Storage of DPS at room temperature was possible for 90 or 30 days and at -20 °C for at least 180 or 90 days at viral loads of 10,000 or 1000 copies/ml, respectively. The HIV-1 pol-genotyping assay presented here is a sensitive, robust and subtype generic tool for a large-scale population-based HIV-1 drug resistance surveillance for the use of DSS/DPS.
Collapse
Affiliation(s)
- Andrea Hauser
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany.
| | | | - Patrycja Machnowska
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Stefan Fiedler
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Kirsten Hanke
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Alexandra Hofmann
- Division of HIV/AIDS, STI and Blood-borne Infections, Robert Koch-Institute, Berlin, Germany; Charité, Universitätsmedizin, Berlin, Germany
| | - Barbara Bartmeyer
- Division of HIV/AIDS, STI and Blood-borne Infections, Robert Koch-Institute, Berlin, Germany
| | - Viviane Bremer
- Division of HIV/AIDS, STI and Blood-borne Infections, Robert Koch-Institute, Berlin, Germany
| | - Norbert Bannert
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Claudia Kuecherer
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| |
Collapse
|
2
|
Machnowska P, Hauser A, Meixenberger K, Altmann B, Bannert N, Rempis E, Schnack A, Decker S, Braun V, Busingye P, Rubaihayo J, Harms G, Theuring S. Decreased emergence of HIV-1 drug resistance mutations in a cohort of Ugandan women initiating option B+ for PMTCT. PLoS One 2017; 12:e0178297. [PMID: 28562612 PMCID: PMC5451067 DOI: 10.1371/journal.pone.0178297] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Accepted: 05/10/2017] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Since 2012, WHO guidelines for the prevention of mother-to-child transmission (PMTCT) of HIV-1 in resource-limited settings recommend the initiation of lifelong antiretroviral combination therapy (cART) for all pregnant HIV-1 positive women independent of CD4 count and WHO clinical stage (Option B+). However, long-term outcomes regarding development of drug resistance are lacking until now. Therefore, we analysed the emergence of drug resistance mutations (DRMs) in women initiating Option B+ in Fort Portal, Uganda, at 12 and 18 months postpartum (ppm). METHODS AND FINDINGS 124 HIV-1 positive pregnant women were enrolled within antenatal care services in Fort Portal, Uganda. Blood samples were collected at the first visit prior starting Option B+ and postpartum at week six, month six, 12 and 18. Viral load was determined by real-time RT-PCR. An RT-PCR covering resistance associated positions in the protease and reverse transcriptase HIV-1 genomic region was performed. PCR-positive samples at 12/18 ppm and respective baseline samples were analysed by next generation sequencing regarding HIV-1 drug resistant variants including low-frequency variants. Furthermore, vertical transmission of HIV-1 was analysed. 49/124 (39.5%) women were included into the DRM analysis. Virological failure, defined as >1000 copies HIV-1 RNA/ml, was observed in three and seven women at 12 and 18 ppm, respectively. Sequences were obtained for three and six of these. In total, DRMs were detected in 3/49 (6.1%) women. Two women displayed dual-class resistance against all recommended first-line regimen drugs. Of 49 mother-infant-pairs no infant was HIV-1 positive at 12 or 18 ppm. CONCLUSION Our findings suggest that the WHO-recommended Option B+ for PMTCT is effective in a cohort of Ugandan HIV-1 positive pregnant women with regard to the low selection rate of DRMs and vertical transmission. Therefore, these results are encouraging for other countries considering the implementation of lifelong cART for all pregnant HIV-1 positive women.
Collapse
Affiliation(s)
- Patrycja Machnowska
- Institute of Tropical Medicine and International Health, Charité—Universitätsmedizin Berlin, Berlin, Germany
- Division of HIV and Other Retroviruses, Robert Koch-Institute, Berlin, Germany
| | - Andrea Hauser
- Division of HIV and Other Retroviruses, Robert Koch-Institute, Berlin, Germany
| | | | - Britta Altmann
- Division of HIV and Other Retroviruses, Robert Koch-Institute, Berlin, Germany
| | - Norbert Bannert
- Division of HIV and Other Retroviruses, Robert Koch-Institute, Berlin, Germany
| | - Eva Rempis
- Institute of Tropical Medicine and International Health, Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Alexandra Schnack
- Institute of Tropical Medicine and International Health, Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Sarah Decker
- Institute of Tropical Medicine and International Health, Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Vera Braun
- Institute of Tropical Medicine and International Health, Charité—Universitätsmedizin Berlin, Berlin, Germany
| | | | - John Rubaihayo
- Department of Public Health, Mountains of the Moon University, Fort Portal, Uganda
| | - Gundel Harms
- Institute of Tropical Medicine and International Health, Charité—Universitätsmedizin Berlin, Berlin, Germany
| | - Stefanie Theuring
- Institute of Tropical Medicine and International Health, Charité—Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
3
|
Hauser A, Hofmann A, Hanke K, Bremer V, Bartmeyer B, Kuecherer C, Bannert N. National molecular surveillance of recently acquired HIV infections in Germany, 2013 to 2014. ACTA ACUST UNITED AC 2017; 22:30436. [PMID: 28105988 PMCID: PMC5404484 DOI: 10.2807/1560-7917.es.2017.22.2.30436] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Accepted: 08/23/2016] [Indexed: 11/20/2022]
Abstract
To enable an up-to-date molecular analysis of human immunodeficiency virus (HIV) genotypes circulating in Germany we have established a surveillance system based on recently acquired HIV infections. New HIV infections are reported to the Robert Koch Institute as a statutory duty for anonymous notification. In 2013 and 2014, a dried serum spot (DSS) sample was received from 6,371 newly diagnosed HIV-cases; their analysis suggested that 1,797 samples originated from a recent infection. Of these, 809 were successfully genotyped in the pol region to identify transmitted drug resistance (TDR) mutations and to determine the HIV-1 subtype. Total TDR was 10.8%, comprising 4.3% with mono-resistance to nucleoside reverse transcriptase inhibitors (NRTIs), 2.6% to non-NRTIs, 3.0% to protease inhibitors and 0.6% and 0.2%, respectively, with dual- and triple-class resistances. HIV-1 subtype B was most prevalent with 77.0%. Non-B infections were identified more often in men and women with heterosexual transmission compared with intravenous drug users or men who have sex with men (79% and 76%, 33%, 12%; all p < 0.05). Non-B subtypes were also more frequently found in patients originating from countries other than Germany (46% vs 14%; p < 0.05) and in patients infected outside of Germany (63% vs 14%; p < 0.05).
Collapse
Affiliation(s)
- Andrea Hauser
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Alexandra Hofmann
- Division of HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin,
Germany.,Charité - Universitätsmedizin, Berlin, Germany
| | - Kirsten Hanke
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Viviane Bremer
- Division of HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin,
Germany
| | - Barbara Bartmeyer
- Division of HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin,
Germany
| | - Claudia Kuecherer
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Norbert Bannert
- Division of HIV and Other Retroviruses, Robert Koch Institute, Berlin, Germany
| |
Collapse
|
4
|
Comparison of 454 Ultra-Deep Sequencing and Allele-Specific Real-Time PCR with Regard to the Detection of Emerging Drug-Resistant Minor HIV-1 Variants after Antiretroviral Prophylaxis for Vertical Transmission. PLoS One 2015; 10:e0140809. [PMID: 26469189 PMCID: PMC4607442 DOI: 10.1371/journal.pone.0140809] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Accepted: 09/29/2015] [Indexed: 12/21/2022] Open
Abstract
Background Pregnant HIV-infected women were screened for the development of HIV-1 drug resistance after implementation of a triple-antiretroviral transmission prophylaxis as recommended by the WHO in 2006. The study offered the opportunity to compare amplicon-based 454 ultra-deep sequencing (UDS) and allele-specific real-time PCR (ASPCR) for the detection of drug-resistant minor variants in the HIV-1 reverse transcriptase (RT). Methods Plasma samples from 34 Tanzanian women were previously analysed by ASPCR for key resistance mutations in the viral RT selected by AZT, 3TC, and NVP (K70R, K103N, Y181C, M184V, T215Y/F). In this study, the RT region of the same samples was investigated by amplicon-based UDS for resistance mutations using the 454 GS FLX System. Results Drug-resistant HIV-variants were identified in 69% (20/29) of women by UDS and in 45% (13/29) by ASPCR. The absolute number of resistance mutations identified by UDS was twice that identified by ASPCR (45 vs 24). By UDS 14 of 24 ASPCR-detected resistance mutations were identified at the same position. The overall concordance between UDS and ASPCR was 61.0% (25/41). The proportions of variants quantified by UDS were approximately 2–3 times lower than by ASPCR. Amplicon generation from samples with viral loads below 20,000 copies/ml failed more frequently by UDS compared to ASPCR (limit of detection = 650 copies/ml), resulting in missing or insufficient sequence coverage. Conclusions Both methods can provide useful information about drug-resistant minor HIV-1 variants. ASPCR has a higher sensitivity than UDS, but is restricted to single resistance mutations. In contrast, UDS is limited by its requirement for high viral loads to achieve sufficient sequence coverage, but the sequence information reveals the complete resistance patterns within the genomic region analysed. Improvements to the UDS limit of detection are in progress, and UDS could then facilitate monitoring of drug-resistant minor variants in the HIV-1 quasispecies.
Collapse
|
5
|
Effective serological and molecular screening of deceased tissue donors. Cell Tissue Bank 2013; 14:633-44. [PMID: 23354598 DOI: 10.1007/s10561-012-9358-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2012] [Accepted: 12/17/2012] [Indexed: 10/27/2022]
Abstract
A comprehensive and effective screening programme is essential to support the banking of tissues from deceased donors. However, the overall quality of the samples obtained from deceased donors, quantity and condition, is often not ideal, and this may lead to problems in achieving accurate and reliable results. Additionally a significant percentage of referrals are still rejected upon receipt as unsuitable for screening. We are actively involved in improving the overall quality of deceased donor screening outcomes, and have specifically evaluated and validated both serological and molecular assays for this purpose, as well as developing a specific screening strategy to minimise the specificity issues associated with serological screening. Here we review the nature and effectiveness of the deceased donor screening programme implemented by National Health Service Blood and Transplant (NHSBT), the organisation with overall responsibility for the supply of tissue products within England. Deceased donor screening data, serological and molecular, from August 2007 until May 2012 have been collated and analysed. Of 10,225 samples referred for serology screening, 5.5 % were reported as reactive; of 2,862 samples referred for molecular screening, 0.1 % were reported as reactive/inhibitory. Overall 20 % of the serological and 100 % of the molecular screen reactivity was confirmed as reflecting true infection. The use of a sequential serology screening algorithm has resulted in a marked reduction of tissues lost unnecessarily due to non-specific screen reactivity. The approach taken by NHSBT has resulted in the development of an effective and specific approach to the screening of deceased tissue donors.
Collapse
|
6
|
Weidner J, Cassens U, Göhde W, Sibrowski W, Odaibo G, Olaleye D, Reichelt D, Greve B. An improved PCR method for detection of HIV-1 proviral DNA of a wide range of subtypes and recombinant forms circulating globally. J Virol Methods 2010; 172:22-6. [PMID: 21182872 DOI: 10.1016/j.jviromet.2010.12.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2009] [Revised: 12/02/2010] [Accepted: 12/13/2010] [Indexed: 10/18/2022]
Abstract
Proviral DNAs are being measured increasingly as a marker of the efficacy of highly active anti-retroviral therapy (HAART) and is accepted for the early diagnosis of perinatal HIV-1 infections. This requires a standardized test which enables the detection of a wide range of subtypes worldwide including O, N and circulating recombinant forms (CRFs). Based on a previous publication, a PCR - Test for HIV-1 provirus detection in peripheral blood mononuclear cells (PBMCs) was developed. Blood samples from 80 individuals infected with HIV-1 and 20 persons negative for HIV-1&2 from Africa and Germany were tested for the presence of HIV-1 provirus DNA. The primer system used enables the detection of proviral DNA despite the high concentrations of human DNA. The limit of detection was determined to be 5 copies per 10(5) cells. All 20 samples from persons negative for HIV were negative for HIV-1 proviral DNA while provirus DNA was amplified from 76 of the 80 (95%) samples from persons infected with HIV. The amplified products were detected by gel-electrophoresis, flow cytometry and real-time PCR. All three detection systems provided the same results.
Collapse
|
7
|
Greve B, Weidner J, Cassens U, Odaibo G, Olaleye D, Sibrowski W, Reichelt D, Nasdala I, Göhde W. A new affordable flow cytometry based method to measure HIV-1 viral load. Cytometry A 2009; 75:199-206. [DOI: 10.1002/cyto.a.20676] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
8
|
Abstract
Objectifs Depuis les dix dernières années, l’introduction de la biologie moléculaire et l’automatisation ont radicalement changé les pratiques dans les laboratoires de microbiologie clinique. L’amélioration de la communication entre les microbiologistes et les cliniciens ainsi que les évolutions technologiques telles que la standardisation et le développement de tests diagnostics plus rapides ont conduit à une réorganisation des laboratoires de microbiologie. Méthodes Jusqu’à présent la prescription des examens ciblait un diagnostic étiologique précis, actuellement l’évolution se fait vers le diagnostic par syndrome incluant un panel de tests regroupant les étiologies responsables d’un syndrome donné y compris les pathogènes émergents. Résultats et conclusions Dans cette revue, nous avons résumé les développements technologiques les plus récents en matière de diagnostic microbiologique adapté au diagnostic par syndrome incluant les stratégies de diagnostic exhaustif, les DNA microarray et les microarray antigéniques.
Collapse
|
9
|
Development of the 1st International Reference Panel for HIV-1 RNA genotypes for use in nucleic acid-based techniques. J Virol Methods 2008; 154:86-91. [PMID: 18793673 DOI: 10.1016/j.jviromet.2008.08.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2008] [Revised: 08/20/2008] [Accepted: 08/21/2008] [Indexed: 11/22/2022]
Abstract
Twenty-eight laboratories from 16 countries participated in a collaborative study to evaluate an HIV-1 RNA Genotype Reference Panel for use with nucleic acid-based tests (NAT). The Reference Panel consisted of 11 coded samples representing different HIV-1 genotypes (subtypes A-D, AE, F, G, AA-GH, groups N and O) as well as a negative diluent control. Each laboratory assayed the eleven panel members concurrently with the 1st International Standard for HIV-1 RNA (NIBSC Code 97/656) on at least three separate occasions and the data collated and analysed at NIBSC. Twenty-nine sets of data from NAT were received, 19 from quantitative and 10 from qualitative assays, with six different commercial assays and five "in-house" assays represented. The results showed that viruses from subtypes A-D and recombinant virus AE [CRF01_AE] were detected consistently, but that some assays had difficulty with the detection and quantification of viruses from subtypes F and G, a mixed recombinant virus AA-GH and a representative of group N. Furthermore, most assays failed to detect the group O representative. The study illustrated the limitations of some molecular assays particularly in detection of certain non-B genotypes which are important viruses in the global AIDS pandemic and illustrated the value of a well-characterised genotype panel. The panel has been established by the World Health Organisation's Expert Committee on Biological Standardisation as the 1st International Reference Panel HIV-1 RNA Genotypes (code 01/466).
Collapse
|
10
|
Wendel S, Levi JE, Takaoka DT, Silva IC, Castro JPD, Torezan-Filho MA, Ghaname J, Gioachini R, Brandão J, Durigon EL. Primary screening of blood donors by nat testing for HCV-RNA: development of an "in-house" method and results. Rev Inst Med Trop Sao Paulo 2007; 49:177-85. [PMID: 17625696 DOI: 10.1590/s0036-46652007000300008] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2005] [Accepted: 11/24/2006] [Indexed: 11/22/2022] Open
Abstract
An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.
Collapse
Affiliation(s)
- Silvano Wendel
- Banco de Sangue, Hospital Sírio Libanês, São Paulo, SP, Brasil.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Levi JE, Wendel S, Takaoka DT, Silva IC, Castro JPD, Torezan-Filho MA, Ghaname J, Gioachini R, Brandão J, Landi EP, Teixeira AC, Durigon EL. Replacement of HIV p24 Ag test by a multiplex RT-PCR method for primary screening of blood donors. Rev Inst Med Trop Sao Paulo 2007; 49:171-6. [PMID: 17625695 DOI: 10.1590/s0036-46652007000300007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2005] [Accepted: 11/24/2006] [Indexed: 11/22/2022] Open
Abstract
Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.
Collapse
|
12
|
Jarvis LM, Dow BC, Cleland A, Davidson F, Lycett C, Morris K, Webb B, Jordan A, Petrik J. Detection of HCV and HIV-1 antibody negative infections in Scottish and Northern Ireland blood donations by nucleic acid amplification testing. Vox Sang 2005; 89:128-34. [PMID: 16146504 DOI: 10.1111/j.1423-0410.2005.00686.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND OBJECTIVES To reduce the risk of transfusion-transmissible viruses entering the blood supply, the nucleic acid amplification testing (NAT) was implemented to screen Scottish and Northern Irish blood donations in minipools. After 5 years of NAT for hepatitis C virus (HCV) and 2 years for human immunodeficiency virus-1 (HIV-1), the yield of serologically negative, nucleic acid positive 'window donations' and cost-benefit of NAT is under review. MATERIALS AND METHODS When the Scottish National Blood Transfusion Service (SNBTS) implemented NAT in 1999, a fully automated 'black box' system was not available. Therefore, an 'in-house' assimilated NAT assay was developed, validated and implemented. The system is flexible and allows testing for additional viral markers to be introduced with relative ease. RESULTS The HCV and HIV NAT assays have 95% detection levels of 7.25 IU/ml and 39.8 IU/ml, respectively, as determined by probit analysis. One HCV (1 in 1.9 million) and one HIV (1 in 0.77 million) window donation have been detected in 5 and 2 years, respectively, of NAT. CONCLUSION The SNBTS NAT assays are robust and have performed consistently over the last 5 years. The design of the in-house system allowed HIV NAT to be added in 2003 at a relatively small additional cost per sample, although for both assays, the royalty fee far exceeds the cost of the test itself. Clearly NAT has a benefit in improving the safety of the blood supply although the risks of transfusion-transmitted viral infections, as reported in the Serious Hazards of Transfusion (SHOT) report, are extremely low. Also, in UK the yield of HCV antibody negative, NAT positive donations is far lower than predicted although the early detection of an HIV window period donation and the increase of HIV in the blood donor and general populations may provide a stronger case for HIV NAT. SUMMARY SENTENCE: The yield of HCV and HIV NAT in UK is significantly less than that anticipated from statistical models.
Collapse
Affiliation(s)
- L M Jarvis
- Scottish National Blood Transfusion Service, Transfusion Transmissible Infections Group, University of Edinburgh, Edinburgh, Scotland, UK.
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Adami V, Falasca E, Dorotea L, Malangone W, Astori G, Marini L, Biffoni F, Rinaldi C, Degrassi A, Pipan C. Qualitative multiplex RT-PCR for simultaneous detection of hepatitis C virus and human immunodeficiency virus in plasma samples. Clin Microbiol Infect 2005; 10:1075-80. [PMID: 15606634 DOI: 10.1111/j.1469-0691.2004.01025.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This report describes the development of a one-tube multiplex reverse transcriptase (RT)-PCR assay for the simultaneous detection of hepatitis C virus (HCV) and human immunodeficiency virus (HIV) in plasma samples. The assay was evaluated with two panels of HCV- and HIV-1-positive samples, as well as negative plasma specimens. Extraction and amplification of HCV and HIV-1 RNA from plasma samples were performed in a single reaction, and amplified genomes were detected with specific probes. Serial dilutions of the HCV and HIV-1 first World Health Organization International Standards were used to evaluate the sensitivity of the method. Two RNA controls were constructed to determine inter-assay variations and the sensitivity of the amplification step. The assay had good specificity and detected all the genotypes and subtypes tested. The analytical sensitivity of the entire assay was 100 IU/mL for HCV and 200 IU/mL for HIV-1, while the amplification step detected ten copies/reaction for HCV and 20 copies/reaction for HIV-1. The multiplex assay allowed the simultaneous extraction, amplification and detection of two virus genomes, thereby providing an important practical advantage and an efficient approach for analysing individual and pooled plasma donations.
Collapse
Affiliation(s)
- V Adami
- Consorzio Fenice, DRMM University of Undine, Udine, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Bhattacharya B, Weiss RA, Davis C, Holmes H, Hockley D, Fassati A. Detection and quantitation of human immunodeficiency virus type-1 particles by confocal microscopy. J Virol Methods 2004; 120:13-21. [PMID: 15234805 DOI: 10.1016/j.jviromet.2004.03.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2004] [Accepted: 03/23/2004] [Indexed: 10/26/2022]
Abstract
A method is described to visualise directly human immunodeficiency virus type-1 (HIV-1) particles. HIV-1 containing samples were adsorbed onto a plastic surface and doubly labeled with antibodies specific for viral proteins and sensitive nucleic acids dyes. Laser scanning confocal microscopy detected co-localization of viral proteins and nucleic acids, thus allowing specific identification of HIV. Using this technique, we have quantified eight different HIV-1 sub-types and three HIV-1 groups in tissue culture supernatants from infected peripheral blood mononuclear cells (PBMCs). Confocal counts correlated well with electron microscopy (EM) counts and HIV-1 RNA loads as determined by quantitative PCR. Confocal microscopy may prove to be a simple alternative to electron microscopy for virus identification and quantitation.
Collapse
Affiliation(s)
- Bishnupriya Bhattacharya
- Department of Immunology and Molecular Pathology, Windeyer Institute of Medical Sciences, Medical School, Royal Free and University College London, 46 Cleveland Street, London W1T 4JF, UK
| | | | | | | | | | | |
Collapse
|
15
|
Welch J, Maclaran K, Jordan T, Simmonds P. Frequency, viral loads, and serotype identification of enterovirus infections in Scottish blood donors. Transfusion 2003; 43:1060-6. [PMID: 12869111 DOI: 10.1046/j.1537-2995.2003.00463.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Enteroviruses are non-enveloped, frequently pathogenic RNA viruses infecting humans. Infection is potentially transmissible through blood or blood component transfusion from donor in the viremic phase before seroconversion for antibody. To investigate the threat to blood safety from enteroviruses, a large-scale survey of frequency and levels of viremia in blood donors was conducted. STUDY DESIGNS AND METHODS Blood donations from Scotland over a period of 22 calendar months were screened for enterovirus RNA sequences by PCR. Positive samples were quantified, and serotypes were identified by nucleotide sequencing of VP1. RESULTS From a total of 3658 pools of 95 donations tested, 73 samples that were enterovirus-positive were identified (corrected annual frequency 0.024% or 1 in 4000). The highest rates of viremia were in late summer months (e.g., 0.055%, 1 in 1800 in July) and lowest from January to May (0.009 and 0.012%). Viral loads ranged from 500 (the lower cutoff of the assay) to greater than 100,000 amplifiable enterovirus template copies per mL. Coxsackievirus A16, echoviruses 11 and 30, and enterovirus 71 were most often identified. CONCLUSIONS The detection of enterovirus-positive blood units indicates the potential for enteroviral transmission by blood components. Although the infrastructure established for PCR-based screening for HCV RNA would allow parallel screening for enteroviruses, any decision concerning donor testing would require further information on the outcome of transfusion-acquired enterovirus infections.
Collapse
Affiliation(s)
- Jon Welch
- Laboratory for Clinical and Molecular Virology, University of Edinburgh, Summerhall, Edinburgh, UK
| | | | | | | |
Collapse
|
16
|
Affiliation(s)
- P R Grant
- Department of Virology, Royal Free and University College Medical School, The Windeyer Institute, London, UK.
| | | |
Collapse
|
17
|
Affiliation(s)
- L M Jarvis
- Scottish National Blood Transfusion Service NAT Reference Unit, Royal Dick Veterinary College, University of Edinburgh, Summerhall, Edinburgh, UK.
| | | |
Collapse
|