1
|
McConnochie G, Fox A, Badger H, Bellenger C, Thewlis D. Fatigue assessment in distance runners: A scoping review of inertial sensor-based biomechanical outcomes and their relation to fatigue markers and assessment conditions. Gait Posture 2025; 115:21-33. [PMID: 39471649 DOI: 10.1016/j.gaitpost.2024.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Academic Contribution Register] [Received: 05/21/2024] [Revised: 09/23/2024] [Accepted: 10/13/2024] [Indexed: 11/01/2024]
Abstract
BACKGROUND Fatigue manifests as a decline in performance during high-intensity and prolonged exercise. With technological advancements and the increasing adoption of inertial measurement units (IMUs) in sports biomechanics, there is an opportunity to enhance our understanding of running-related fatigue beyond controlled laboratory environments. RESEARCH QUESTION How have IMUs have been used to assess running biomechanics under fatiguing conditions? METHODS Following the PRISMA-ScR guidelines, our literature search covered six databases without date restrictions until September 2024. The Population, Concept, and Context criteria were used: Population (distance runners ranging from novice to competitive), Concept (fatigue induced by running a distance over 400 m), Context (assessment of fatigue using accelerometer, gyroscope, and/or magnetometer wearable devices). Biomechanical outcomes were extracted and synthesised, and interpreted in the context of three main study characteristics (cohort ability, testing environment, and the inclusion of physiological outcomes) to explore their potential role in influencing outcomes. RESULTS A total of 88 articles were included in the review. There was a high prevalence of treadmill-based studies (n=46, 52%), utilising only 1-2 sensors (n=69, 78%), and cohorts ranged in experience, from sedentary to elite-level runners, and were largely comprised of males (69% of all participants). The majority of biomechanical outcomes assessed showed varying responses to fatigue across studies, likely attributable to individual variability, exercise intensity, and differences in fatigue protocol settings and prescriptions. Spatiotemporal outcomes such as stride time and frequency (n=37, 42 %) and impact accelerations (n=55, 62%) were more widely assessed, with a fatigue response that appeared population and environment specific. SIGNIFICANCE There was notable heterogeneity in the IMU-based biomechanical outcomes and methods evaluated in this review. The review findings emphasise the need for standardisation of IMU-based outcomes and fatigue protocols to promote interpretable metrics and facilitate inter-study comparisons.
Collapse
Affiliation(s)
- Grace McConnochie
- Centre for Orthopaedic & Trauma Research, Adelaide Medical School, University of Adelaide, Australia.
| | - Aaron Fox
- Institute for Physical Activity and Nutrition, School of Exercise and Nutrition Sciences, Deakin University, Australia
| | - Heather Badger
- Centre for Orthopaedic & Trauma Research, Adelaide Medical School, University of Adelaide, Australia
| | - Clint Bellenger
- Alliance for Research in Exercise, Nutrition and Activity (ARENA); Allied Health and Human Performance Unit; University of South Australia, Australia
| | - Dominic Thewlis
- Centre for Orthopaedic & Trauma Research, Adelaide Medical School, University of Adelaide, Australia
| |
Collapse
|
2
|
Mason R, Celik Y, Barry G, Godfrey A, Stuart S. Instrumenting Parkrun: Usefulness and Validity of Inertial Sensors. SENSORS (BASEL, SWITZERLAND) 2024; 25:30. [PMID: 39796819 PMCID: PMC11723058 DOI: 10.3390/s25010030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Academic Contribution Register] [Received: 11/08/2024] [Revised: 12/20/2024] [Accepted: 12/24/2024] [Indexed: 01/13/2025]
Abstract
The analysis of running gait has conventionally taken place within an expensive and restricted laboratory space, with wearable technology offering a practical, cost-effective, and unobtrusive way to examine running gait in more natural environments. This pilot study presents a wearable inertial measurement unit (IMU) setup for the continuous analysis of running gait during an outdoor parkrun (i.e., 5 km). The study aimed to (1) provide analytical validation of running gait measures compared to time- and age-graded performance and (2) explore performance validation. Ten healthy adults (7 females, 3 males, mean age 37.2 ± 11.7 years) participated. The participants wore Axivity AX6 IMUs on the talus joint of each foot, recording tri-axial accelerometer and gyroscope data at 200 Hz. Temporal gait characteristics-gait cycle, ground contact time, swing time, and duty factor-were extracted using zero-crossing algorithms. The data were analyzed for correlations between the running performance, foot strike type, and fatigue-induced changes in temporal gait characteristics. Strong correlations were found between the performance time and both the gait cycle and ground contact time, with weak correlations for foot strike types. The analysis of asymmetry and fatigue highlighted modest changes in gait as fatigue increased, but no significant gender differences were found. This setup demonstrates potential for in-field gait analysis for running, providing insights for performance and injury prevention strategies.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne NE1 8ST, UK; (R.M.); (G.B.)
| | - Yunus Celik
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne NE1 8ST, UK; (Y.C.); (A.G.)
| | - Gill Barry
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne NE1 8ST, UK; (R.M.); (G.B.)
| | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne NE1 8ST, UK; (Y.C.); (A.G.)
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne NE1 8ST, UK; (R.M.); (G.B.)
- Department of Neurology, Oregon Health and Science University, Portland, OR 97239, USA
| |
Collapse
|
3
|
Mason R, Barry G, Hall G, Godfrey A, Stuart S. Validity and reliability of running gait measurement with the ViMove2 system. PLoS One 2024; 19:e0312952. [PMID: 39480797 PMCID: PMC11527157 DOI: 10.1371/journal.pone.0312952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 05/01/2024] [Accepted: 10/16/2024] [Indexed: 11/02/2024] Open
Abstract
Running biomechanics have traditionally been analysed in laboratory settings, but this may not reflect natural running gait. Wearable technology has the potential to enable precise monitoring of running gait beyond the laboratory. This study aimed to evaluate the analytical validity and intra-session reliability of temporal running gait outcomes measured by the ViMove2 wearable system in healthy adults. Seventy-four healthy adults (43 males, 31 females, aged 18-55 years) wore the inertial device, ViMove2 on the tibia. Participants ran on a treadmill for one minute at various speeds (8, 10, 12, 14km/hr), completed in a standardised shoe (Saucony Guide Runner). Running gait was measured with the ViMove2 wearable and 3D motion capture (Vicon). Temporal running gait outcomes included ground contact time (GCT) and cadence (steps/min). GCT and cadence from the ViMove2 had face validity with expected changes in outcome with different running speeds, but ViMove2 tended to over-estimate GCT, and under-estimate cadence compared to the reference, especially at slower speeds. GCT demonstrated moderate to good agreement to the reference at speeds >10km/hr, but poor agreement at 8km/hr and within female runners. Cadence had moderate to excellent agreement across speeds compared to the reference. GCT and cadence had excellent reliability across speeds, but at 8km/hr GCT had good agreement between trials. Overall, temporal gait outcomes of GCT and cadence can be measured with the ViMove2, but accuracy and reliability are impacted at slow running speeds and within female runners. Future work is needed to clarify sex or speed-dependent corrections to algorithms / outcomes to aid interpretation and application.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Gillian Barry
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Gary Hall
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
- Department of Neurology, Oregon Health and Science University, Portland, Oregon, United States of America
| |
Collapse
|
4
|
Kiernan D, Katzman ZD, Hawkins DA, Christiansen BA. A 0.05 m Change in Inertial Measurement Unit Placement Alters Time and Frequency Domain Metrics during Running. SENSORS (BASEL, SWITZERLAND) 2024; 24:656. [PMID: 38276348 PMCID: PMC10820910 DOI: 10.3390/s24020656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Academic Contribution Register] [Received: 11/20/2023] [Revised: 01/12/2024] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
Inertial measurement units (IMUs) provide exciting opportunities to collect large volumes of running biomechanics data in the real world. IMU signals may, however, be affected by variation in the initial IMU placement or movement of the IMU during use. To quantify the effect that changing an IMU's location has on running data, a reference IMU was 'correctly' placed on the shank, pelvis, or sacrum of 74 participants. A second IMU was 'misplaced' 0.05 m away, simulating a 'worst-case' misplacement or movement. Participants ran over-ground while data were simultaneously recorded from the reference and misplaced IMUs. Differences were captured as root mean square errors (RMSEs) and differences in the absolute peak magnitudes and timings. RMSEs were ≤1 g and ~1 rad/s for all axes and misplacement conditions while mean differences in the peak magnitude and timing reached up to 2.45 g, 2.48 rad/s, and 9.68 ms (depending on the axis and direction of misplacement). To quantify the downstream effects of these differences, initial and terminal contact times and vertical ground reaction forces were derived from both the reference and misplaced IMU. Mean differences reached up to -10.08 ms for contact times and 95.06 N for forces. Finally, the behavior in the frequency domain revealed high coherence between the reference and misplaced IMUs (particularly at frequencies ≤~10 Hz). All differences tended to be exaggerated when data were analyzed using a wearable coordinate system instead of a segment coordinate system. Overall, these results highlight the potential errors that IMU placement and movement can introduce to running biomechanics data.
Collapse
Affiliation(s)
- Dovin Kiernan
- Biomedical Engineering Graduate Group, University of California Davis, Davis, CA 95616, USA (B.A.C.)
| | - Zachary David Katzman
- Department of Neurobiology, Physiology & Behavior, University of California Davis, Davis, CA 95616, USA
- College of Podiatric Medicine and Surgery, Des Moines University, West Des Moines, IA 50266, USA
| | - David A. Hawkins
- Biomedical Engineering Graduate Group, University of California Davis, Davis, CA 95616, USA (B.A.C.)
- Department of Neurobiology, Physiology & Behavior, University of California Davis, Davis, CA 95616, USA
| | - Blaine Andrew Christiansen
- Biomedical Engineering Graduate Group, University of California Davis, Davis, CA 95616, USA (B.A.C.)
- Department of Orthopaedic Surgery, University of California Davis, Davis, CA 95616, USA
| |
Collapse
|
5
|
Mason R, Barry G, Robinson H, O'Callaghan B, Lennon O, Godfrey A, Stuart S. Validity and reliability of the DANU sports system for walking and running gait assessment. Physiol Meas 2023; 44:115001. [PMID: 37852268 DOI: 10.1088/1361-6579/ad04b4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 07/04/2023] [Accepted: 10/18/2023] [Indexed: 10/20/2023]
Abstract
Objective. Gait assessments have traditionally been analysed in laboratory settings, but this may not reflect natural gait. Wearable technology may offer an alternative due to its versatility. The purpose of the study was to establish the validity and reliability of temporal gait outcomes calculated by the DANU sports system, against a 3D motion capture reference system.Approach. Forty-one healthy adults (26 M, 15 F, age 36.4 ± 11.8 years) completed a series of overground walking and jogging trials and 60 s treadmill walking and running trials at various speeds (8-14 km hr-1), participants returned for a second testing session to repeat the same testing.Main results. For validity, 1406 steps and 613 trials during overground and across all treadmill trials were analysed respectively. Temporal outcomes generated by the DANU sports system included ground contact time, swing time and stride time all demonstrated excellent agreement compared to the laboratory reference (intraclass correlation coefficient (ICC) > 0.900), aside from ground contact time during overground jogging which had good agreement (ICC = 0.778). For reliability, 666 overground and 511 treadmill trials across all speeds were examined. Test re-test agreement was excellent for all outcomes across treadmill trials (ICC > 0.900), except for swing time during treadmill walking which had good agreement (ICC = 0.886). Overground trials demonstrated moderate to good test re-test agreement (ICC = 0.672-0.750), which may be due to inherent variability of self-selected (rather than treadmill set) pacing between sessions.Significance. Overall, this study showed that temporal gait outcomes from the DANU Sports System had good to excellent validity and moderate to excellent reliability in healthy adults compared to an established laboratory reference.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Gillian Barry
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | | | | | | | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcasle upon Tyne, United Kingdom
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
- Department of Neurology, Oregon Health and Science University, Portland, OR, United States of America
- Northumbria Healthcare NHS Foundation Trust, North Shields, United Kingdom
| |
Collapse
|
6
|
Mason R, Pearson LT, Barry G, Young F, Lennon O, Godfrey A, Stuart S. Wearables for Running Gait Analysis: A Systematic Review. Sports Med 2023; 53:241-268. [PMID: 36242762 PMCID: PMC9807497 DOI: 10.1007/s40279-022-01760-6] [Citation(s) in RCA: 35] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Accepted: 08/21/2022] [Indexed: 01/12/2023]
Abstract
BACKGROUND Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance. OBJECTIVES We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults. METHODS A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings. RESULTS A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards. CONCLUSIONS This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes. CLINICAL TRIAL REGISTRATION CRD42021235527.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Liam T Pearson
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Gillian Barry
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Fraser Young
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, UK
| | | | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK.
- Northumbria Healthcare NHS Foundation Trust, Newcastle upon Tyne, UK.
| |
Collapse
|
7
|
Zeng Z, Liu Y, Hu X, Tang M, Wang L. Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis. SPORTS MEDICINE - OPEN 2022; 8:86. [PMID: 35759130 PMCID: PMC9237201 DOI: 10.1186/s40798-022-00477-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Academic Contribution Register] [Received: 11/23/2021] [Accepted: 06/11/2022] [Indexed: 11/13/2022]
Abstract
Background Inertial measurement units (IMUs) are useful in monitoring running and alerting running-related injuries in various sports settings. However, the quantitative summaries of the validity and reliability of the measurements from IMUs during running are still lacking. The purpose of this review was to investigate the concurrent validity and test–retest reliability of IMUs for measuring gait spatiotemporal outcomes and lower extremity kinematics of health adults during running. Methods PubMed, CINAHL, Embase, Scopus and Web of Science electronic databases were searched from inception until September 2021. The inclusion criteria were as follows: (1) evaluated the validity or reliability of measurements from IMUs, (2) measured specific kinematic outcomes, (3) compared measurements using IMUs with those obtained using reference systems, (4) collected data during running, (5) assessed human beings and (6) were published in English. Eligible articles were reviewed using a modified quality assessment. A meta-analysis was performed to assess the pooled correlation coefficients of validity and reliability. Results Twenty-five articles were included in the systematic review, and data from 12 were pooled for meta-analysis. The methodological quality of studies ranged from low to moderate. Concurrent validity is excellent for stride length (intraclass correlation coefficient (ICC) (95% confidence interval (CI)) = 0.937 (0.859, 0.972), p < 0.001), step frequency (ICC (95% CI) = 0.926 (0.896, 0.948), r (95% CI) = 0.989 (0.957, 0.997), p < 0.001) and ankle angle in the sagittal plane (r (95% CI) = 0.939 (0.544, 0.993), p = 0.002), moderate to excellent for stance time (ICC (95% CI) = 0.664 (0.354, 0.845), r (95% CI) = 0.811 (0.701, 0.881), p < 0.001) and good for running speed (ICC (95% CI) = 0.848 (0.523, 0.958), p = 0.0003). The summary Fisher's Z value of flight time was not statistically significant (p = 0.13). Similarly, the stance time showed excellent test–retest reliability (ICC (95% CI) = 0.954 (0.903, 0.978), p < 0.001) and step frequency showed good test–retest reliability (ICC (95% CI) = 0.896 (0.837, 0.933), p < 0.001). Conclusions Findings in the current review support IMUs measurement of running gait spatiotemporal parameters, but IMUs measurement of running kinematics on lower extremity joints needs to be reported with caution in healthy adults. Trial Registration: PROSPERO Registration Number: CRD42021279395. Supplementary Information The online version contains supplementary material available at 10.1186/s40798-022-00477-0.
Collapse
|
8
|
Apte S, Troxler S, Besson C, Gremeaux V, Aminian K. Augmented Cooper test: Biomechanical contributions to endurance performance. Front Sports Act Living 2022; 4:935272. [PMID: 36187713 PMCID: PMC9515446 DOI: 10.3389/fspor.2022.935272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 05/03/2022] [Accepted: 08/04/2022] [Indexed: 11/23/2022] Open
Abstract
Running mechanics are modifiable with training and adopting an economical running technique can improve running economy and hence performance. While field measurement of running economy is cumbersome, running mechanics can be assessed accurately and conveniently using wearable inertial measurement units (IMUs). In this work, we extended this wearables-based approach to the Cooper test, by assessing the relative contribution of running biomechanics to the endurance performance. Furthermore, we explored different methods of estimating the distance covered in the Cooper test using a wearable global navigation satellite system (GNSS) receiver. Thirty-three runners (18 highly trained and 15 recreational) performed an incremental laboratory treadmill test to measure their maximum aerobic speed (MAS) and speed at the second ventilatory threshold (sVT2). They completed a 12-minute Cooper running test with foot-worm IMUs and a chest-worn GNSS-IMU on a running track 1–2 weeks later. Using the GNSS receiver, an accurate estimation of the 12-minute distance was obtained (accuracy of 16.5 m and precision of 1.1%). Using this distance, we showed a reliable estimation [R2 > 0.9, RMSE ϵ (0.07, 0.25) km/h] of the MAS and sVT2. Biomechanical metrics were extracted using validated algorithm and their association with endurance performance was estimated. Additionally, the high-/low-performance runners were compared using pairwise statistical testing. All performance variables, MAS, sVT2, and average speed during Cooper test, were predicted with an acceptable error (R2 ≥ 0.65, RMSE ≤ 1.80 kmh−1) using only the biomechanical metrics. The most relevant metrics were used to develop a biomechanical profile representing the running technique and its temporal evolution with acute fatigue, identifying different profiles for runners with highest and lowest endurance performance. This profile could potentially be used in standardized functional capacity measurements to improve personalization of training and rehabilitation programs.
Collapse
Affiliation(s)
- Salil Apte
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- *Correspondence: Salil Apte
| | - Simone Troxler
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
| | - Cyril Besson
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
- Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland
| | - Vincent Gremeaux
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
- Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland
| | - Kamiar Aminian
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| |
Collapse
|
9
|
Young F, Mason R, Wall C, Morris R, Stuart S, Godfrey A. Examination of a foot mounted IMU-based methodology for a running gait assessment. Front Sports Act Living 2022; 4:956889. [PMID: 36147582 PMCID: PMC9485551 DOI: 10.3389/fspor.2022.956889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 05/30/2022] [Accepted: 08/10/2022] [Indexed: 11/13/2022] Open
Abstract
Gait assessment is essential to understand injury prevention mechanisms during running, where high-impact forces can lead to a range of injuries in the lower extremities. Information regarding the running style to increase efficiency and/or selection of the correct running equipment, such as shoe type, can minimize the risk of injury, e.g., matching a runner's gait to a particular set of cushioning technologies found in modern shoes (neutral/support cushioning). Awareness of training or selection of the correct equipment requires an understanding of a runner's biomechanics, such as determining foot orientation when it strikes the ground. Previous work involved a low-cost approach with a foot-mounted inertial measurement unit (IMU) and an associated zero-crossing-based methodology to objectively understand a runner's biomechanics (in any setting) to learn about shoe selection. Here, an investigation of the previously presented ZC-based methodology is presented only to determine general validity for running gait assessment in a range of running abilities from novice (8 km/h) to experienced (16 km/h+). In comparison to Vicon 3D motion tracking data, the presented approach can extract pronation, foot strike location, and ground contact time with good [ICC(2,1) > 0.750] to excellent [ICC(2,1) > 0.900] agreement between 8-12 km/h runs. However, at higher speeds (14 km/h+), the ZC-based approach begins to deteriorate in performance, suggesting that other features and approaches may be more suitable for faster running and sprinting tasks.
Collapse
Affiliation(s)
- Fraser Young
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Conor Wall
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Rosie Morris
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom
| | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, United Kingdom
| |
Collapse
|
10
|
Billat V, Poinsard L, Palacin F, Pycke JR, Maron M. Oxygen Uptake Measurements and Rate of Perceived Exertion during a Marathon. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19095760. [PMID: 35565153 PMCID: PMC9104840 DOI: 10.3390/ijerph19095760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Academic Contribution Register] [Received: 04/05/2022] [Revised: 05/02/2022] [Accepted: 05/04/2022] [Indexed: 02/06/2023]
Abstract
Although the marathon race has been democratized, it remains complex due to the famous “hitting the wall” phenomenon after the 25th km. To characterize this “wall” from a physiological and Rate of Perceived Exertion (RPE) perspective in recreational marathon runners, we report first continuous breath-by-breath gas exchange measurements during an actual marathon race. In order to test the hypothesis that RPE could be a candidate for controlling the marathon pace, this study examined the relationship between RPE and the physiological variables time course throughout a marathon. Only the respiratory frequency and heart rate increased progressively during the race in all the runners, while the oxygen uptake and ventilatory rate followed different kinetics according the individuals. However, the indexation of the physiological parameters and speed by RPE showed the same decreased tendency for all the runners. In conclusion, these results suggest that running a marathon must be self-paced with the RPE.
Collapse
Affiliation(s)
- Véronique Billat
- Department of STAPS, Université Paris-Saclay, Univ Evry, 91000 Evry-Courcouronnes, France;
- Laboratory of Neurophysiology and Movement Biomechanics, Université Libre de Bruxelles Neuroscience Institut, 1070 Bruxelles, Belgium;
| | - Luc Poinsard
- Laboratory of Neurophysiology and Movement Biomechanics, Université Libre de Bruxelles Neuroscience Institut, 1070 Bruxelles, Belgium;
| | - Florent Palacin
- Laboratory of Neurophysiology and Movement Biomechanics, Université Libre de Bruxelles Neuroscience Institut, 1070 Bruxelles, Belgium;
- Correspondence:
| | - Jean Renaud Pycke
- UMR8071-CNRS-Laboratoire de Mathématiques et Modélisation d’Evry, Université Paris-Saclay, Univ Evry, 91000 Evry-Courcouronnes, France;
| | - Michael Maron
- Department of Integrative Medical Sciences, Northeast Ohio Medical University, Rootstown, OH 44272 , USA;
| |
Collapse
|
11
|
Marotta L, Scheltinga BL, van Middelaar R, Bramer WM, van Beijnum BJF, Reenalda J, Buurke JH. Accelerometer-Based Identification of Fatigue in the Lower Limbs during Cyclical Physical Exercise: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:3008. [PMID: 35458993 PMCID: PMC9025833 DOI: 10.3390/s22083008] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Academic Contribution Register] [Received: 03/22/2022] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 02/01/2023]
Abstract
Physical exercise (PE) is beneficial for both physical and psychological health aspects. However, excessive training can lead to physical fatigue and an increased risk of lower limb injuries. In order to tailor training loads and durations to the needs and capacities of an individual, physical fatigue must be estimated. Different measurement devices and techniques (i.e., ergospirometers, electromyography, and motion capture systems) can be used to identify physical fatigue. The field of biomechanics has succeeded in capturing changes in human movement with optical systems, as well as with accelerometers or inertial measurement units (IMUs), the latter being more user-friendly and adaptable to real-world scenarios due to its wearable nature. There is, however, still a lack of consensus regarding the possibility of using biomechanical parameters measured with accelerometers to identify physical fatigue states in PE. Nowadays, the field of biomechanics is beginning to open towards the possibility of identifying fatigue state using machine learning algorithms. Here, we selected and summarized accelerometer-based articles that either (a) performed analyses of biomechanical parameters that change due to fatigue in the lower limbs or (b) performed fatigue identification based on features including biomechanical parameters. We performed a systematic literature search and analysed 39 articles on running, jumping, walking, stair climbing, and other gym exercises. Peak tibial and sacral acceleration were the most common measured variables and were found to significantly increase with fatigue (respectively, in 6/13 running articles and 2/4 jumping articles). Fatigue classification was performed with an accuracy between 78% and 96% and Pearson's correlation with an RPE (rate of perceived exertion) between r = 0.79 and r = 0.95. We recommend future effort toward the standardization of fatigue protocols and methods across articles in order to generalize fatigue identification results and increase the use of accelerometers to quantify physical fatigue in PE.
Collapse
Affiliation(s)
- Luca Marotta
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Bouke L. Scheltinga
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Robbert van Middelaar
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Wichor M. Bramer
- Medical Library, Erasmus University Medical Center, 3000 CA Rotterdam, The Netherlands;
| | - Bert-Jan F. van Beijnum
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Jasper Reenalda
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Jaap H. Buurke
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
- Roessingh Rehabilitation Centre, 7522 AH Enschede, The Netherlands
| |
Collapse
|
12
|
Prigent G, Apte S, Paraschiv-Ionescu A, Besson C, Gremeaux V, Aminian K. Concurrent Evolution of Biomechanical and Physiological Parameters With Running-Induced Acute Fatigue. Front Physiol 2022; 13:814172. [PMID: 35222081 PMCID: PMC8874325 DOI: 10.3389/fphys.2022.814172] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Academic Contribution Register] [Received: 11/12/2021] [Accepted: 01/10/2022] [Indexed: 12/28/2022] Open
Abstract
Understanding the influence of running-induced acute fatigue on the homeostasis of the body is essential to mitigate the adverse effects and optimize positive adaptations to training. Fatigue is a multifactorial phenomenon, which influences biomechanical, physiological, and psychological facets. This work aimed to assess the evolution of these three facets with acute fatigue during a half-marathon. 13 recreational runners were equipped with one inertial measurement unit (IMU) on each foot, one combined global navigation satellite system-IMU-electrocardiogram sensor on the chest, and an Android smartphone equipped with an audio recording application. Spatio-temporal parameters for the running gait, along with the heart rate, its variability and complexity were computed using validated algorithms. Perceived fatigability was assessed using the rating-of-fatigue (ROF) scale at every 10 min of the race. The data was split into eight equal segments, corresponding to at least one ROF value per segment, and only level running parts were retained for analysis. During the race, contact time, duty factor, and trunk anteroposterior acceleration increased, and the foot strike angle and vertical stiffness decreased significantly. Heart rate showed a progressive increase, while the metrics for heart rate variability and complexity decreased during the race. The biomechanical parameters showed a significant alteration even with a small change in perceived fatigue, whereas the heart rate dynamics altered at higher changes. When divided into two groups, the slower runners presented a higher change in heart rate dynamics throughout the race than the faster runners; they both showed similar trends for the gait parameters. When tested for linear and non-linear correlations, heart rate had the highest association with biomechanical parameters, while the trunk anteroposterior acceleration had the lowest association with heart rate dynamics. These results indicate the ability of faster runners to better judge their physiological limits and hint toward a higher sensitivity of perceived fatigue to neuromuscular changes in the running gait. This study highlights measurable influences of acute fatigue, which can be studied only through concurrent measurement of biomechanical, physiological, and psychological facets of running in real-world conditions.
Collapse
Affiliation(s)
- Gäelle Prigent
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Salil Apte
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Anisoara Paraschiv-Ionescu
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Cyril Besson
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
- Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland
| | - Vincent Gremeaux
- Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital, Lausanne, Switzerland
- Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland
| | - Kamiar Aminian
- Laboratory of Movement Analysis and Measurement, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| |
Collapse
|