1
|
Nagy A, Czitrovszky A, Lehoczki A, Farkas Á, Füri P, Osán J, Groma V, Kugler S, Micsinai A, Horváth A, Ungvári Z, Müller V. Creating respiratory pathogen-free environments in healthcare and nursing-care settings: a comprehensive review. GeroScience 2024:10.1007/s11357-024-01379-7. [PMID: 39392557 DOI: 10.1007/s11357-024-01379-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Accepted: 10/03/2024] [Indexed: 10/12/2024] Open
Abstract
Hospital- and nursing-care-acquired infections are a growing problem worldwide, especially during epidemics, posing a significant threat to older adults in geriatric settings. Intense research during the COVID-19 pandemic highlighted the prominent role of aerosol transmission of pathogens. Aerosol particles can easily adsorb different airborne pathogens, carrying them for a long time. Understanding the dynamics of airborne pathogen transmission is essential for controlling the spread of many well-known pathogens, like the influenza virus, and emerging ones like SARS-CoV-2. Particles smaller than 50 to 100 µm remain airborne and significantly contribute to pathogen transmission. This review explores the journey of pathogen-carrying particles from formation in the airways, through airborne travel, to deposition in the lungs. The physicochemical properties of emitted particles depend on health status and emission modes, such as breathing, speaking, singing, coughing, sneezing, playing wind instruments, and medical interventions. After emission, sedimentation and evaporation primarily determine particle fate. Lung deposition of inhaled aerosol particles can be studied through in vivo, in vitro, or in silico methods. We discuss several numerical lung models, such as the Human Respiratory Tract Model, the LUng Dose Evaluation Program software (LUDEP), the Stochastic Lung Model, and the Computational Fluid Dynamics (CFD) techniques, and real-time or post-evaluation methods for detecting and characterizing these particles. Various air purification methods, particularly filtration, are reviewed for their effectiveness in healthcare settings. In the discussion, we analyze how this knowledge can help create environments with reduced PM2.5 and pathogen levels, enhancing safety in healthcare and nursing-care settings. This is particularly crucial for protecting older adults, who are more vulnerable to infections due to weaker immune systems and the higher prevalence of chronic conditions. By implementing effective airborne pathogen control measures, we can significantly improve health outcomes in geriatric settings.
Collapse
Affiliation(s)
- Attila Nagy
- Department of Applied and Nonlinear Optics, HUN-REN Wigner Research Centre for Physics, Konkoly-Thege Miklós St. 29-33, 1121, Budapest, Hungary.
| | - Aladár Czitrovszky
- Department of Applied and Nonlinear Optics, HUN-REN Wigner Research Centre for Physics, Konkoly-Thege Miklós St. 29-33, 1121, Budapest, Hungary
| | - Andrea Lehoczki
- Doctoral College, Health Sciences Program, Semmelweis University, Budapest, Hungary
- Institute of Preventive Medicine and Public Health, Semmelweis University, Budapest, Hungary
| | - Árpád Farkas
- Environmental Physics Department, HUN-REN Centre for Energy Research, Budapest, Hungary
| | - Péter Füri
- Environmental Physics Department, HUN-REN Centre for Energy Research, Budapest, Hungary
| | - János Osán
- Environmental Physics Department, HUN-REN Centre for Energy Research, Budapest, Hungary
| | - Veronika Groma
- Environmental Physics Department, HUN-REN Centre for Energy Research, Budapest, Hungary
| | - Szilvia Kugler
- Environmental Physics Department, HUN-REN Centre for Energy Research, Budapest, Hungary
| | | | - Alpár Horváth
- Department of Pulmonology, Semmelweis University, Budapest, Hungary
| | - Zoltán Ungvári
- Vascular Cognitive Impairment and Neurodegeneration Program, Oklahoma Center for Geroscience and Healthy Brain Aging, Department of Biochemistry & Molecular Biology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, 731042, USA
- Peggy and Charles Stephenson Cancer Center, Oklahoma City, OK, 73104, USA
- Department of Health Promotion Sciences, College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
- International Training Program in Geroscience, Doctoral School of Basic and Translational Medicine/Institute of Preventive Medicine and Public Health, Semmelweis University, Budapest, Hungary
| | - Veronika Müller
- Department of Pulmonology, Semmelweis University, Budapest, Hungary
| |
Collapse
|
2
|
Robinson JM, Liddicoat C, Sun X, Ramesh S, Hawken S, Lee K, Brame J, Fickling NW, Kuhn E, Hayward C, Deshmukh S, Robinson K, Cando‐Dumancela C, Breed MF. The climate change-pollution-aerobiome nexus: A 'systems thinking' mini-review. Microb Biotechnol 2024; 17:e70018. [PMID: 39401032 PMCID: PMC11472731 DOI: 10.1111/1751-7915.70018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Accepted: 09/07/2024] [Indexed: 10/15/2024] Open
Abstract
The interrelationship between climate change, pollution and the aerobiome (the microbiome of the air) is a complex ecological dynamic with profound implications for human and ecosystem health. This mini-review explores the multifaceted relationships among these factors. By synthesising existing research and integrating interdisciplinary perspectives, we examine the mechanisms driving interactions within the climate change-pollution-aerobiome nexus. We also explore synergistic and cascading effects and potential impacts on human health (including both communicable and non-communicable diseases) and that of wider ecosystems. Based on our mini-review results, climate change influences air pollution and, independently, air pollution affects the composition, diversity and activity of the aerobiome. However, we apply a 'systems thinking' approach and create a set of systems diagrams to show that climate change likely influences the aerobiome (including bacteria and fungi) via climate change-pollution interactions in complex ways. Due to the inherent complexity of these systems, we emphasise the importance of holistic and/or interdisciplinary approaches and collaborative efforts in understanding this nexus to safeguard planetary health in an era of rapid environmental change.
Collapse
Affiliation(s)
- Jake M. Robinson
- College of Science and EngineeringFlinders UniversityBedford ParkSouth AustraliaAustralia
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
| | - Craig Liddicoat
- College of Science and EngineeringFlinders UniversityBedford ParkSouth AustraliaAustralia
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
| | - Xin Sun
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
- Key Laboratory of Urban Environment and Health, Ningbo Observation and Research Station, Fujian Key Laboratory of Watershed Ecology, Institute of Urban EnvironmentChinese Academy of SciencesXiamenChina
| | - Sunita Ramesh
- College of Science and EngineeringFlinders UniversityBedford ParkSouth AustraliaAustralia
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
| | - Scott Hawken
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
- School of Architecture and Civil EngineeringThe University of AdelaideAdelaideSouth AustraliaAustralia
| | - Kevin Lee
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
- Department of Food Science and Microbiology, School of ScienceAuckland University of TechnologyEast Auckland CityNew Zealand
| | - Joel Brame
- College of Science and EngineeringFlinders UniversityBedford ParkSouth AustraliaAustralia
- School of Biotechnology and Biomolecular SciencesUniversity of New South WalesKensingtonNew South WalesAustralia
| | - Nicole W. Fickling
- College of Science and EngineeringFlinders UniversityBedford ParkSouth AustraliaAustralia
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
| | - Emma Kuhn
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
- Environmental Health, College of Science and EngineeringFlinders UniversityAdelaideSouth AustraliaAustralia
| | - Claire Hayward
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
- Environmental Health, College of Science and EngineeringFlinders UniversityAdelaideSouth AustraliaAustralia
| | - Sonali Deshmukh
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
- Environmental Health, College of Science and EngineeringFlinders UniversityAdelaideSouth AustraliaAustralia
| | - Kate Robinson
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
| | - Christian Cando‐Dumancela
- College of Science and EngineeringFlinders UniversityBedford ParkSouth AustraliaAustralia
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
| | - Martin F. Breed
- College of Science and EngineeringFlinders UniversityBedford ParkSouth AustraliaAustralia
- The Aerobiome Innovation and Research HubFlinders UniversityBedford ParkSouth AustraliaAustralia
| |
Collapse
|
3
|
Tuhkuri Matvejeff A, Laitinen A, Korhonen M, Oksanen LM, Geneid A, Sanmark E, Vuorinen V. Superspreading of SARS-CoV-2 at a choir rehearsal in Finland-A computational fluid dynamics view on aerosol transmission and patient interviews. PLoS One 2024; 19:e0302250. [PMID: 39264883 PMCID: PMC11392323 DOI: 10.1371/journal.pone.0302250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 03/31/2024] [Indexed: 09/14/2024] Open
Abstract
INTRODUCTION COVID-19 pandemic has highlighted the role of aerosol transmission and the importance of superspreading events. We analyzed a choir rehearsal in November 2020, where all participants, except one who had recently earlier recovered from COVID-19, were infected. We explore the risk factors for severe disease in this event and model the aerosol dispersion in the rehearsal room. MATERIALS AND METHODS Characteristics of participants were collected by interviews and supplemented with patient records. A computational simulation of aerosol distribution in the rehearsal room and the efficacy of potential safety measures was conducted using the Large-Eddy Simulation approach. Infection risk was studied by analyzing quanta emission and exposure with the Wells-Riley equation. RESULTS The simulation showed that airborne transmission likely explains this mass contagion event. Every singer was exposed to the virus in only 5 min from the beginning of the rehearsal, and maximum concentration levels were reached at 20 min the concentration levels started to approach a steady state after 20 min. Although concentration differences existed in the room, risk levels near (1 m) and far (5 m) from the aerosol source were similar for certain singers. Modeling indicated infection risk levels of 70-100% after one hour; the risk would have been considerably reduced by wearing high-filtration respirators. Age and pre-existing comorbidities predicted more severe disease. The high incidence of illness may be partly attributed to the relatively high median age of individuals. Additionally, those admitted to the hospital had multiple underlying health conditions that predispose them to more severe disease. CONCLUSIONS Airborne transmission and indoor space can explain this mass exposure event. High-filtration respirators could have prevented some infections. The importance of safety distances diminishes the longer the indoor event. The concept of safety distance is challenging, as our study suggests that long range airborne transmission may occur in indoor events with extended duration. We encourage informing the public, especially persons at risk, of safety measures during epidemics.
Collapse
Affiliation(s)
- Anna Tuhkuri Matvejeff
- Department of Otorhinolaryngology and Phoniatrics - Head and Neck Surgery, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Alpo Laitinen
- Department of Mechanical Engineering, Aalto University, Espoo, Finland
| | - Marko Korhonen
- Department of Mechanical Engineering, Aalto University, Espoo, Finland
| | - Lotta-Maria Oksanen
- Department of Otorhinolaryngology and Phoniatrics - Head and Neck Surgery, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Ahmed Geneid
- Department of Otorhinolaryngology and Phoniatrics - Head and Neck Surgery, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Enni Sanmark
- Department of Otorhinolaryngology and Phoniatrics - Head and Neck Surgery, Helsinki University Hospital, University of Helsinki, Helsinki, Finland
| | - Ville Vuorinen
- Department of Mechanical Engineering, Aalto University, Espoo, Finland
| |
Collapse
|
4
|
Alqarni Z, Rezgui Y, Petri I, Ghoroghi A. Viral infection transmission and indoor air quality: A systematic review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 923:171308. [PMID: 38432379 DOI: 10.1016/j.scitotenv.2024.171308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 02/03/2024] [Accepted: 02/25/2024] [Indexed: 03/05/2024]
Abstract
Respiratory disease transmission in indoor environments presents persistent challenges for health authorities, as exemplified by the recent COVID-19 pandemic. This underscores the urgent necessity to investigate the dynamics of viral infection transmission within indoor environments. This systematic review delves into the methodologies of respiratory infection transmission in indoor settings and explores how the quality of indoor air (IAQ) can be controlled to alleviate this risk while considering the imperative of sustainability. Among the 2722 articles reviewed, 178 were retained based on their focus on respiratory viral infection transmission and IAQ. Fifty eight articles delved into SARS-CoV-2 transmission, 21 papers evaluated IAQ in contexts of other pandemics, 53 papers assessed IAQ during the SARS-CoV-2 pandemic, and 46 papers examined control strategies to mitigate infectious transmission. Furthermore, of the 46 papers investigating control strategies, only nine considered energy consumption. These findings highlight clear gaps in current research, such as analyzing indoor air and surface samples for specific indoor environments, oversight of indoor and outdoor parameters (e.g., temperature, relative humidity (RH), and building orientation), neglect of occupancy schedules, and the absence of considerations for energy consumption while enhancing IAQ. This study distinctly identifies the indoor environmental conditions conducive to the thriving of each respiratory virus, offering IAQ trade-offs to mitigate the risk of dominant viruses at any given time. This study argues that future research should involve digital twins in conjunction with machine learning (ML) techniques. This approach aims to enhance IAQ by analyzing the transmission patterns of various respiratory viruses while considering energy consumption.
Collapse
Affiliation(s)
- Zahi Alqarni
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK; School of Computer Science, King Khalid University, Abha 62529, Saudi Arabia.
| | - Yacine Rezgui
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ioan Petri
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ali Ghoroghi
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| |
Collapse
|
5
|
Nazari A, Taghizadeh-Hesary F. Numerical investigation of airborne infection risk in an elevator cabin under different ventilation designs. PHYSICS OF FLUIDS 2023; 35. [DOI: 10.1063/5.0152878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/21/2024]
Abstract
Airborne transmission of SARS-CoV-2 via virus-laden aerosols in enclosed spaces poses a significant concern. Elevators, commonly utilized enclosed spaces in modern tall buildings, present a challenge as the impact of varying heating, ventilation, and air conditioning (HVAC) systems on virus transmission within these cabins remains unclear. In this study, we employ computational modeling to examine aerosol transmission within an elevator cabin outfitted with diverse HVAC systems. Using a transport equation, we model aerosol concentration and assess infection risk distribution across passengers' breathing zones. We calculate the particle removal efficiency for each HVAC design and introduce a suppression effect criterion to evaluate the effectiveness of the HVAC systems. Our findings reveal that mixing ventilation, featuring both inlet and outlet at the ceiling, proves most efficient in reducing particle spread, achieving a maximum removal efficiency of 79.40% during the exposure time. Conversely, the stratum ventilation model attains a mere removal efficiency of 3.97%. These results underscore the importance of careful HVAC system selection in mitigating the risk of SARS-CoV-2 transmission within elevator cabins.
Collapse
Affiliation(s)
- Ata Nazari
- University of Tabriz, Department of Mechanical Engineering 1 , Tabriz, Iran
| | - Farzad Taghizadeh-Hesary
- ENT and Head and Neck Research Center and Department, The Five Senses Health Institute, School of Medicine, Iran University of Medical Sciences 5 , Tehran, Iran
| |
Collapse
|
6
|
Groma V, Kugler S, Farkas Á, Füri P, Madas B, Nagy A, Erdélyi T, Horváth A, Müller V, Szántó-Egész R, Micsinai A, Gálffy G, Osán J. Size distribution and relationship of airborne SARS-CoV-2 RNA to indoor aerosol in hospital ward environments. Sci Rep 2023; 13:3566. [PMID: 36864124 PMCID: PMC9980870 DOI: 10.1038/s41598-023-30702-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 02/28/2023] [Indexed: 03/04/2023] Open
Abstract
Aerosol particles proved to play a key role in airborne transmission of SARS-CoV-2 viruses. Therefore, their size-fractionated collection and analysis is invaluable. However, aerosol sampling in COVID departments is not straightforward, especially in the sub-500-nm size range. In this study, particle number concentrations were measured with high temporal resolution using an optical particle counter, and several 8 h daytime sample sets were collected simultaneously on gelatin filters with cascade impactors in two different hospital wards during both alpha and delta variants of concern periods. Due to the large number (152) of size-fractionated samples, SARS-CoV-2 RNA copies could be statistically analyzed over a wide range of aerosol particle diameters (70-10 µm). Our results revealed that SARS-CoV-2 RNA is most likely to exist in particles with 0.5-4 µm aerodynamic diameter, but also in ultrafine particles. Correlation analysis of particulate matter (PM) and RNA copies highlighted the importance of indoor medical activity. It was found that the daily maximum increment of PM mass concentration correlated the most with the number concentration of SARS-CoV-2 RNA in the corresponding size fractions. Our results suggest that particle resuspension from surrounding surfaces is an important source of SARS-CoV-2 RNA present in the air of hospital rooms.
Collapse
Affiliation(s)
- V Groma
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - Sz Kugler
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - Á Farkas
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - P Füri
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - B Madas
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary
| | - A Nagy
- Department of Applied and Nonlinear Optics, Wigner Research Centre for Physics, Budapest, 1121, Hungary
| | - T Erdélyi
- Department of Pulmonology, Semmelweis University, Budapest, 1085, Hungary
| | - A Horváth
- Department of Pulmonology, Semmelweis University, Budapest, 1085, Hungary
- Pest County Pulmonology Hospital, Törökbálint, 2045, Hungary
| | - V Müller
- Department of Pulmonology, Semmelweis University, Budapest, 1085, Hungary
| | | | | | - G Gálffy
- Pest County Pulmonology Hospital, Törökbálint, 2045, Hungary
| | - J Osán
- Environmental Physics Department, Centre for Energy Research, Budapest, 1121, Hungary.
| |
Collapse
|
7
|
Oksanen L, Auvinen M, Kuula J, Malmgren R, Romantschuk M, Hyvärinen A, Laitinen S, Maunula L, Sanmark E, Geneid A, Sofieva S, Salokas J, Veskiväli H, Sironen T, Grönholm T, Hellsten A, Atanasova N. Combining Phi6 as a surrogate virus and computational large-eddy simulations to study airborne transmission of SARS-CoV-2 in a restaurant. INDOOR AIR 2022; 32:e13165. [PMID: 36437671 PMCID: PMC10100099 DOI: 10.1111/ina.13165] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 05/18/2023]
Abstract
COVID-19 has highlighted the need for indoor risk-reduction strategies. Our aim is to provide information about the virus dispersion and attempts to reduce the infection risk. Indoor transmission was studied simulating a dining situation in a restaurant. Aerosolized Phi6 viruses were detected with several methods. The aerosol dispersion was modeled by using the Large-Eddy Simulation (LES) technique. Three risk-reduction strategies were studied: (1) augmenting ventilation with air purifiers, (2) spatial partitioning with dividers, and (3) combination of 1 and 2. In all simulations infectious viruses were detected throughout the space proving the existence long-distance aerosol transmission indoors. Experimental cumulative virus numbers and LES dispersion results were qualitatively similar. The LES results were further utilized to derive the evolution of infection probability. Air purifiers augmenting the effective ventilation rate by 65% reduced the spatially averaged infection probability by 30%-32%. This relative reduction manifests with approximately 15 min lag as aerosol dispersion only gradually reaches the purifier units. Both viral findings and LES results confirm that spatial partitioning has a negligible effect on the mean infection-probability indoors, but may affect the local levels adversely. Exploitation of high-resolution LES jointly with microbiological measurements enables an informative interpretation of the experimental results and facilitates a more complete risk assessment.
Collapse
Affiliation(s)
- Lotta Oksanen
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | | | - Joel Kuula
- Finnish Meteorological InstituteHelsinkiFinland
| | - Rasmus Malmgren
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Martin Romantschuk
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiLahtiFinland
| | | | | | - Leena Maunula
- Faculty of Veterinary Medicine, Food Hygiene and Environmental HealthUniversity of HelsinkiHelsinkiFinland
| | - Enni Sanmark
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | - Ahmed Geneid
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | - Svetlana Sofieva
- Finnish Meteorological InstituteHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Julija Salokas
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Helin Veskiväli
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | - Tarja Sironen
- Department of Virology, Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Veterinary Biosciences, Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | | | | | - Nina Atanasova
- Finnish Meteorological InstituteHelsinkiFinland
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| |
Collapse
|
8
|
Oksanen LAH, Virtanen J, Sanmark E, Rantanen N, Venkat V, Sofieva S, Aaltonen K, Kivistö I, Svirskaite J, Pérez AD, Kuula J, Levanov L, Hyvärinen A, Maunula L, Atanasova NS, Laitinen S, Anttila V, Lehtonen L, Lappalainen M, Geneid A, Sironen T. SARS-CoV-2 indoor environment contamination with epidemiological and experimental investigations. INDOOR AIR 2022; 32:e13118. [PMID: 36305066 PMCID: PMC9828560 DOI: 10.1111/ina.13118] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 08/25/2022] [Accepted: 09/06/2022] [Indexed: 05/02/2023]
Abstract
SARS-CoV-2 has been detected both in air and on surfaces, but questions remain about the patient-specific and environmental factors affecting virus transmission. Additionally, more detailed information on viral sampling of the air is needed. This prospective cohort study (N = 56) presents results from 258 air and 252 surface samples from the surroundings of 23 hospitalized and eight home-treated COVID-19 index patients between July 2020 and March 2021 and compares the results between the measured environments and patient factors. Additionally, epidemiological and experimental investigations were performed. The proportions of qRT-PCR-positive air (10.7% hospital/17.6% homes) and surface samples (8.8%/12.9%) showed statistical similarity in hospital and homes. Significant SARS-CoV-2 air contamination was observed in a large (655.25 m3 ) mechanically ventilated (1.67 air changes per hour, 32.4-421 L/s/patient) patient hall even with only two patients present. All positive air samples were obtained in the absence of aerosol-generating procedures. In four cases, positive environmental samples were detected after the patients had developed a neutralizing IgG response. SARS-CoV-2 RNA was detected in the following particle sizes: 0.65-4.7 μm, 7.0-12.0 μm, >10 μm, and <100 μm. Appropriate infection control against airborne and surface transmission routes is needed in both environments, even after antibody production has begun.
Collapse
Affiliation(s)
- Lotta‐Maria A. H. Oksanen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | - Jenni Virtanen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | - Enni Sanmark
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | - Noora Rantanen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | - Vinaya Venkat
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | - Svetlana Sofieva
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
- Finnish Meteorological InstituteHelsinkiFinland
| | - Kirsi Aaltonen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | - Ilkka Kivistö
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | - Julija Svirskaite
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
| | | | - Joel Kuula
- Finnish Meteorological InstituteHelsinkiFinland
| | - Lev Levanov
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
| | | | - Leena Maunula
- Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| | - Nina S. Atanasova
- Faculty of Biological and Environmental SciencesUniversity of HelsinkiHelsinkiFinland
- Finnish Meteorological InstituteHelsinkiFinland
| | | | - Veli‐Jukka Anttila
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- HUS Inflammation CenterHelsinki University HospitalHelsinkiFinland
| | - Lasse Lehtonen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- HUS Diagnostic Center, HUSLABHelsinki University HospitalHelsinkiFinland
| | - Maija Lappalainen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- HUS Diagnostic Center, HUSLABHelsinki University HospitalHelsinkiFinland
| | - Ahmed Geneid
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Department of Otorhinolaryngology and Phoniatrics – Head and Neck SurgeryHelsinki University HospitalHelsinkiFinland
| | - Tarja Sironen
- Faculty of MedicineUniversity of HelsinkiHelsinkiFinland
- Faculty of Veterinary MedicineUniversity of HelsinkiHelsinkiFinland
| |
Collapse
|
9
|
Stiehl B, Shrestha R, Schroeder S, Delgado J, Bazzi A, Reyes J, Kinzel M, Ahmed K. The effect of relative air humidity on the evaporation timescales of a human sneeze. AIP ADVANCES 2022; 12:075210. [PMID: 35989720 PMCID: PMC9386616 DOI: 10.1063/5.0102078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 06/08/2022] [Indexed: 06/15/2023]
Abstract
The present paper investigates droplet and aerosol emission from the human respiratory function by numerical and experimental methods, which is analyzed at the worst-case scenario, a violent sneeze without a face covering. The research findings develop the understanding of airborne disease transmission relevant to COVID-19, its recent variants, and other airborne pathogens. A human sneeze is studied using a multiphase Computational Fluid Dynamics (CFD) model using detached eddy simulation coupled to the emission of droplets that break up, evaporate, and disperse. The model provides one of the first experimental benchmarks of CFD predictions of a human sneeze event. The experiments optically capture aerosols and droplets and are processed to provide spatiotemporal data to validate the CFD model. Under the context of large random uncertainty, the studies indicate the reasonable correlation of CFD prediction with experimental measurements using velocity profiles and exposure levels, indicating that the model captures the salient details relevant to pathogen dispersion. Second, the CFD model was extended to study the effect of relative humidity with respect to the Wells curve, providing additional insight into the complexities of evaporation and sedimentation characteristics in the context of turbulent and elevated humidity conditions associated with the sneeze. The CFD results indicated correlation with the Wells curve with additional insight into features, leading to non-conservative aspects associated with increased suspension time. These factors are found to be associated with the combination of evaporation and fluid-structure-induced suspension. This effect is studied for various ambient air humidity levels and peaks for lower humidity levels, indicating that the Wells curve may need a buffer in dry climates. Specifically, we find that the increased risk in dry climates may be up to 50% higher than would be predicted using the underlying assumptions in Wells' model.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Kareem Ahmed
- Author to whom correspondence should be addressed: . Tel.: (407) 823-5710
| |
Collapse
|