Marukhyan SS, Hovhannisyan VA, Gasparyan VK. Urease combined with CdSe quantum dots as an enzyme sensor for quantitative detection of some metals in water. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 326:125186. [PMID: 39326222 DOI: 10.1016/j.saa.2024.125186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 09/14/2024] [Accepted: 09/20/2024] [Indexed: 09/28/2024]
Abstract
This investigation illustrates the potential role of urease as an enzymatic sensor in conjunction with CdSe quantum dots (QDs) for the detection of various metals present in aqueous environments. The enzyme urease catalyzes the hydrolysis of urea, resulting to the production of carbon dioxide and ammonia. The formation of ammonia leads to an increase in the pH of the solution, which in turn enhances the fluorescence of the CdSe quantum dots. In contrast, the presence of different metal can inhibit enzyme activity, thereby reducing ammonia production, which results in less pronounced pH changes and a subsequent increase in the fluorescence of the QDs. These variations are dependent on the concentration of the metals, allowing for the detection of several metals in water. This method enables the identification of metals such as Cu, Co, Mg, Fe, Cr, Zn, and Ni, with a detection limit of 0.2 μM. This level of sensitivity is adequate for evaluating the safety of water intended for various food products.
Collapse
Affiliation(s)
- Seda S Marukhyan
- Head of Laboratory of Medical Biotechnology, Institute of Biochemistry, National Academy of Sciences, P.Sevak str.5/1 Yerevan 0014, Armenia
| | - Varduhi A Hovhannisyan
- Head of Laboratory of Medical Biotechnology, Institute of Biochemistry, National Academy of Sciences, P.Sevak str.5/1 Yerevan 0014, Armenia
| | - Vardan K Gasparyan
- Head of Laboratory of Medical Biotechnology, Institute of Biochemistry, National Academy of Sciences, P.Sevak str.5/1 Yerevan 0014, Armenia; BIO-VAR Ltd, P.Sevak str.5/1 Yerevan 0014, Armenia.
| |
Collapse
|
2
|
Hast K, Stone MRL, Jia Z, Baci M, Aggarwal T, Izgu EC. Bioorthogonal Functionalization of Material Surfaces with Bioactive Molecules. ACS APPLIED MATERIALS & INTERFACES 2023; 15:4996-5009. [PMID: 36649474 PMCID: PMC10069157 DOI: 10.1021/acsami.2c20942] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
The functionalization of material surfaces with biologically active molecules is crucial for enabling technologies in life sciences, biotechnology, and medicine. However, achieving biocompatibility and bioorthogonality with current synthetic methods remains a challenge. We report herein a novel surface functionalization method that proceeds chemoselectively and without a free transition metal catalyst. In this method, a coating is first formed via the tyrosinase-catalyzed putative polymerization of a tetrazine-containing catecholamine (DOPA-Tet). One or more types of molecule of interest containing trans-cyclooctene are then grafted onto the coating via tetrazine ligation. The entire process proceeds under physiological conditions and is suitable for grafting bioactive molecules with diverse functions and structural complexities. Utilizing this method, we functionalized material surfaces with enzymes (alkaline phosphatase, glucose oxidase, and horseradish peroxidase), a cyclic peptide (cyclo[Arg-Gly-Asp-D-Phe-Lys], or c(RGDfK)), and an antibiotic (vancomycin). Colorimetric assays confirmed the maintenance of the biocatalytic activities of the grafted enzymes on the surface. We established the mammalian cytocompatibility of the functionalized materials with fibroblasts. Surface functionalization with c(RGDfK) showed improved fibroblast cell morphology and cytoskeletal organization. Microbiological studies with Staphylococcus aureus indicated that surfaces coated using DOPA-Tet inhibit the formation of biofilms. Vancomycin-grafted surfaces additionally display significant inhibition of planktonic S. aureus growth.
Collapse
Affiliation(s)
- Kern Hast
- Department of Chemistry and Chemical Biology, Rutgers University, New Brunswick, New Jersey 08854, United States
| | - M Rhia L Stone
- Department of Chemistry and Chemical Biology, Rutgers University, New Brunswick, New Jersey 08854, United States
| | - Zhaojun Jia
- Department of Chemistry and Chemical Biology, Rutgers University, New Brunswick, New Jersey 08854, United States
| | - Melih Baci
- Department of Chemistry and Chemical Biology, Rutgers University, New Brunswick, New Jersey 08854, United States
| | - Tushar Aggarwal
- Department of Chemistry and Chemical Biology, Rutgers University, New Brunswick, New Jersey 08854, United States
| | - Enver Cagri Izgu
- Department of Chemistry and Chemical Biology, Rutgers University, New Brunswick, New Jersey 08854, United States
- Cancer Pharmacology Program, Cancer Institute of New Jersey, Rutgers University, New Brunswick, New Jersey 08901, United States
- Rutgers Center for Lipid Research, New Jersey Institute for Food, Nutrition, and Health, Rutgers University, New Brunswick, New Jersey 08901, United States
| |
Collapse
|
3
|
Andresen E, Flores-Sanchez IJ, Brückner D, Bokhari SNH, Falkenberg G, Küpper H. Sublethal and lethal Cd toxicity in soybean roots specifically affects the metabolome, Cd binding to proteins and cellular distribution of Cd. JOURNAL OF HAZARDOUS MATERIALS 2023; 442:130062. [PMID: 36183514 DOI: 10.1016/j.jhazmat.2022.130062] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 09/19/2022] [Accepted: 09/22/2022] [Indexed: 06/16/2023]
Abstract
Soybean (Glycine max (L.) Merr.) plants were exposed to various Cd concentrations from background and low non-toxic (0.5-50 nM) via sublethally toxic (< 550 nM) to highly, ultimately lethally toxic (3 µM) concentrations. Plants were cultivated hydroponically for 10 weeks until pod development stage of the control plants. The threshold and mechanism of sublethal Cd toxicity was investigated by metabolomics and metalloproteomics (HPLC-ICP-MS) measuring metal binding to proteins in the harvested roots. Spatial distribution of Cd was revealed by µXRF-CT. Specific binding of Cd to proteins already at 50 nM Cd revealed the likely high-affinity protein binding targets in roots, identified by protein purification from natural abundance. This revealed allantoinase, aquaporins, peroxidases and protein disulfide isomerase as the most likely high-affinity targets of Cd binding. Cd was deposited in cortex cell vacuoles at sublethal and bound to the cell walls of the outer cortex and the vascular bundle at lethal Cd. Cd binding to proteins likely inhibits them, and possibly induces detoxification mechanisms, as verified by metabolomics: allantoic acid and allantoate increased due to sublethal Cd toxicity. Changes of the Cd binding pattern indicated a detoxification strategy at lower Cd, but saturated binding sites at higher Cd concentrations.
Collapse
Affiliation(s)
- Elisa Andresen
- Czech Academy of Sciences, Biology Centre, Institute of Plant Molecular Biology, Department Plant Biophysics and Biochemistry, Branišovská 31/1160, CZ-37005 České Budějovice, Czech Republic
| | - Isvett Josefina Flores-Sanchez
- Czech Academy of Sciences, Biology Centre, Institute of Plant Molecular Biology, Department Plant Biophysics and Biochemistry, Branišovská 31/1160, CZ-37005 České Budějovice, Czech Republic
| | - Dennis Brückner
- Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany
| | - Syed Nadeem Hussain Bokhari
- Czech Academy of Sciences, Biology Centre, Institute of Plant Molecular Biology, Department Plant Biophysics and Biochemistry, Branišovská 31/1160, CZ-37005 České Budějovice, Czech Republic
| | - Gerald Falkenberg
- Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany
| | - Hendrik Küpper
- Czech Academy of Sciences, Biology Centre, Institute of Plant Molecular Biology, Department Plant Biophysics and Biochemistry, Branišovská 31/1160, CZ-37005 České Budějovice, Czech Republic; University of South Bohemia, Faculty of Science, Department of Experimental Plant Biology, Branišovská 31/1160, CZ-37005 České Budějovice, Czech Republic.
| |
Collapse
|
4
|
Basumatary D, Saikia S, Yadav HS, Yadav M. In silico analysis of peroxidase from Luffa acutangula. 3 Biotech 2023; 13:25. [PMID: 36575654 PMCID: PMC9789927 DOI: 10.1007/s13205-022-03432-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Accepted: 12/07/2022] [Indexed: 12/26/2022] Open
Abstract
Peroxidases are oxidoreductase enzymes that widely gained attention as biocatalysts for their robust catalytic activity, specificity, and regioselective functionality for phenolic compounds. The study of molecular aspects of peroxidases is as crucial as that of the physicochemical aspects. A bioinformatics approach is utilized in this study to investigate the structural aspects and functions of luffa peroxidase (LPrx) from Luffa acutangula. The evolutionary relationship of LPrx with other class III peroxidases was studied by constructing a neighbour-joining phylogenetic tree. An analysis of the phylogenetic tree revealed that plant peroxidases share a common ancestor. The gene ontology term showed that LPrx had a molecular functionality of the oxidation-reduction process, heme binding and peroxidase-like activity, and the biological function of hydrogen peroxide scavenging activity. The enzyme-ligand interactions were studied from a catalytic point of view using the molecular docking technique. The molecular docking was carried out with LPrx as a receptor and guaiacol, m-cresol, p-cresol, catechol, quinol, pyrogallol, 2,4-dimethoxyphenol, gallic acid, aniline, and o-phenylenediamine as ligands. The results presented in the current communication will have a significant implication in proteomics, biochemistry, biotechnology, and the potential applications of peroxidases in the biotransformations of organic compounds. Supplementary Information The online version contains supplementary material available at 10.1007/s13205-022-03432-8.
Collapse
Affiliation(s)
- Dencil Basumatary
- Department of Chemistry, North Eastern Regional Institute of Science and Technology, Nirjuli, Arunachal Pradesh 791109 India
| | - Shilpa Saikia
- Department of Chemistry, North Eastern Regional Institute of Science and Technology, Nirjuli, Arunachal Pradesh 791109 India
| | - Hardeo Singh Yadav
- Department of Chemistry, North Eastern Regional Institute of Science and Technology, Nirjuli, Arunachal Pradesh 791109 India
| | - Meera Yadav
- Department of Chemistry, North Eastern Regional Institute of Science and Technology, Nirjuli, Arunachal Pradesh 791109 India
| |
Collapse
|
5
|
Okpara EC, Fayemi OE, Wojuola OB, Onwudiwe DC, Ebenso EE. Electrochemical detection of selected heavy metals in water: a case study of African experiences. RSC Adv 2022; 12:26319-26361. [PMID: 36275116 PMCID: PMC9475415 DOI: 10.1039/d2ra02733j] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 08/30/2022] [Indexed: 11/21/2022] Open
Abstract
The safety of water resources throughout the globe has been compromised by various human activities and climate change over the last decades. Consequently, the world is currently confronted with a severe shortage of water supply and a water safety crisis, amidst a growing population. With poor environmental regulations, indiscriminate budding of urban slums, poverty, and a lack of basic knowledge of hygiene and sanitation, the African water supply has been critically threatened by different organic and inorganic contaminants, which results in several health issues. Inorganic pollutants such as heavy metals are particularly of interest because they are mostly stable and non-biodegradable. Therefore, they are not easily removed from water. In different parts of the continent, the concentration of heavy metals in drinking water far exceeds the permissible level recommended by the World Health Organization (WHO). Worse still, this problem is expected to increase with growing population, industrialization, urbanization, and, of course, corruption of government and local officials. Most of the African population is ignorant of the standards of safe water. In addition, the populace lack access to affordable and reliable technologies and tools that could be used in the quantification of these pollutants. This problem is not only applicable to domestic, but also to commercial, communal, and industrial water sources. Hence, a global campaign has been launched to ensure constant assessment of the presence of these metals in the environment and to promote awareness of dangers associated with unsafe exposure to them. Various conventional spectroscopic heavy metal detection techniques have been used with great success across the world. However, such techniques suffer from some obvious setbacks, such as the cost of procurement and professionalism required to operate them, which have limited their applications. This paper, therefore, reviews the condition of African water sources, health implications of exposure to heavy metals, and the approaches explored by various indigenous electrochemists, to provide a fast, affordable, sensitive, selective, and stable electrochemical sensors for the quantification of the most significant heavy metals in our water bodies.
Collapse
Affiliation(s)
- Enyioma C Okpara
- Department of Physics, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus) Private Bag X2046 Mmabatho 2735 South Africa
| | - Omolola E Fayemi
- Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus) Private Bag X2046 Mmabatho 2735 South Africa
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus) Private Bag X2046 Mmabatho 2735 South Africa
| | - Olanrewaju B Wojuola
- Department of Physics, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus) Private Bag X2046 Mmabatho 2735 South Africa
| | - Damian C Onwudiwe
- Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus) Private Bag X2046 Mmabatho 2735 South Africa
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus) Private Bag X2046 Mmabatho 2735 South Africa
| | - Eno E Ebenso
- College of Science, Engineering and Technology, University of South Africa Johannesburg 1710 South Africa
| |
Collapse
|
6
|
Sabah M, Fethi A. Electrochemical Detection of Lead in Real Samples Using Carbon Nanostructure and Inactivated E. coli as Low-Cost Sensitive Biosensor with High Electrocatalytic Performance. Electrocatalysis (N Y) 2022. [DOI: 10.1007/s12678-022-00760-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
7
|
Attaallah R, Amine A. An Ultrasensitive and Selective Determination of Cadmium Ions at ppt Level Using an Enzymic Membrane with Colorimetric and Electrochemical Detection. BIOSENSORS 2022; 12:bios12050310. [PMID: 35624611 PMCID: PMC9138971 DOI: 10.3390/bios12050310] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 04/30/2022] [Accepted: 05/04/2022] [Indexed: 01/17/2023]
Abstract
Cadmium ions (Cd2+) are extremely toxic heavy metal pollutants found in the environment, and which endanger human health. Therefore, it is critical to develop a sensitive and simple method for rapidly detecting Cd2+ in water samples. Herein, an enzymic membrane was developed based on an easy and rapid immobilization method of horseradish peroxidase (HRP), for determination of Cd2+ in drinking water. Hence, for the first time, an enzymic membrane was applied for the detection of Cd2+ without being pretreated. In the first format, the inhibition of horseradish peroxidase was performed using a colorimetric microplate reader. Under optimal conditions, the achieved limit of detection was 20 ppt. In addition, an electrochemical biosensor was developed, by combining the enzymic membrane with screen printed electrodes, which showed a linear calibration range between 0.02–100 ppb (R2 = 0.990) and a detection limit of 50 ppt. The use of this enzymic membrane proved to be advantageous when reversible inhibitors such as the copper ion (Cu2+) were present in water samples, as Cu2+ can interfere with Cd2+ and cause erroneous results. In order to alleviate this problem, a medium exchange procedure was used to eliminate Cu2+, by washing and leaving only cadmium ions as an irreversible inhibitor for identification. The use of this membrane proved to be a simple and rapid method of immobilizing HRP with a covalent bond.
Collapse
|
8
|
Apak R, Calokerinos A, Gorinstein S, Segundo MA, Hibbert DB, Gülçin İ, Demirci Çekiç S, Güçlü K, Özyürek M, Çelik SE, Magalhães LM, Arancibia-Avila P. Methods to evaluate the scavenging activity of antioxidants toward reactive oxygen and nitrogen species (IUPAC Technical Report). PURE APPL CHEM 2021. [DOI: 10.1515/pac-2020-0902] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Abstract
This project was aimed to identify the quenching chemistry of biologically important reactive oxygen and nitrogen species (ROS/RNS, including radicals), to show antioxidant action against reactive species through H‐atom and electron transfer reactions, and to evaluate the ROS/RNS scavenging activity of antioxidants with existing analytical methods while emphasizing the underlying chemical principles and advantages/disadvantages of these methods. In this report, we focused on the applications and impact of existing assays on potentiating future research and innovations to evolve better methods enabling a more comprehensive study of different aspects of antioxidants and to provide a vocabulary of terms related to antioxidants and scavengers for ROS/RNS. The main methods comprise the scavenging activity measurement of the hydroxyl radical (•OH), dioxide(•1–) (O2
•–: commonly known as the superoxide radical), dihydrogen dioxide (H2O2: commonly known as hydrogen peroxide), hydroxidochlorine (HOCl: commonly known as hypochlorous acid), dioxidooxidonitrate(1–) (ONOO−: commonly known as the peroxynitrite anion), and the peroxyl radical (ROO•). In spite of the diversity of methods, there is currently a great need to evaluate the scavenging activity of antioxidant compounds in vivo and in vitro. In addition, there are unsatisfactory methods frequently used, such as non-selective UV measurement of H2O2 scavenging, producing negative errors due to incomplete reaction of peroxide with flavonoids in the absence of transition metal ion catalysts. We also discussed the basic mechanisms of spectroscopic and electrochemical nanosensors for measuring ROS/RNS scavenging activity of antioxidants, together with leading trends and challenges and a wide range of applications. This project aids in the identification of reactive species and quantification of scavenging extents of antioxidants through various assays, makes the results comparable and more understandable, and brings a more rational basis to the evaluation of these assays and provides a critical evaluation of existing ROS/RNS scavenging assays to analytical, food chemical, and biomedical/clinical communities by emphasizing the need for developing more refined, rapid, simple, and low‐cost assays and thus opening the market for a wide range of analytical instruments, including reagent kits and sensors.
Collapse
Affiliation(s)
- Reşat Apak
- Department of Chemistry , Istanbul University-Cerrahpaşa, Faculty of Engineering , Avcılar, 34320 Istanbul , Turkey
| | - Antony Calokerinos
- Department of Chemistry , National and Kapodistrian University of Athens, School of Sciences , Panepistimiopolis, 15771 Athens , Greece
| | - Shela Gorinstein
- The Hebrew University, Hadassah Medical School, School of Pharmacy, The Institute for Drug Research , Jerusalem , Israel
| | - Marcela Alves Segundo
- Department of Chemical Sciences , LAQV, REQUIMTE, Faculty of Pharmacy, University of Porto , Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto , Portugal
| | - David Brynn Hibbert
- New South Wales University, School of Chemistry , Sydney , NSW 2052 , Australia
| | - İlhami Gülçin
- Department of Chemistry , Faculty of Science, Atatürk University , Erzurum , Turkey
| | - Sema Demirci Çekiç
- Department of Chemistry , Istanbul University-Cerrahpaşa, Faculty of Engineering , Avcılar, 34320 Istanbul , Turkey
| | - Kubilay Güçlü
- Department of Chemistry , Adnan Menderes University, Faculty of Arts and Sciences , Aydın , Turkey
| | - Mustafa Özyürek
- Department of Chemistry , Istanbul University-Cerrahpaşa, Faculty of Engineering , Avcılar, 34320 Istanbul , Turkey
| | - Saliha Esin Çelik
- Department of Chemistry , Istanbul University-Cerrahpaşa, Faculty of Engineering , Avcılar, 34320 Istanbul , Turkey
| | - Luís M. Magalhães
- Department of Chemical Sciences , LAQV, REQUIMTE, Faculty of Pharmacy, University of Porto , Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto , Portugal
| | - Patricia Arancibia-Avila
- Departamento de Ciencias Básicas , Laboratorio de Ecofisiología y Microalgas, Universidad del Bio-Bio , Chillán , Chile
| |
Collapse
|
9
|
Designing of Nanomaterials-Based Enzymatic Biosensors: Synthesis, Properties, and Applications. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2010012] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Among the many biological entities employed in the development of biosensors, enzymes have attracted the most attention. Nanotechnology has been fostering excellent prospects in the development of enzymatic biosensors, since enzyme immobilization onto conductive nanostructures can improve characteristics that are crucial in biosensor transduction, such as surface-to-volume ratio, signal response, selectivity, sensitivity, conductivity, and biocatalytic activity, among others. These and other advantages of nanomaterial-based enzymatic biosensors are discussed in this work via the compilation of several reports on their applications in different industrial segments. To provide detailed insights into the state of the art of this technology, all the relevant concepts around the topic are discussed, including the properties of enzymes, the mechanisms involved in their immobilization, and the application of different enzyme-derived biosensors and nanomaterials. Finally, there is a discussion around the pressing challenges in this technology, which will be useful for guiding the development of future research in the area.
Collapse
|
10
|
Şen FB, Bener M, Bekdeşer B, Apak R. Redox-based colorimetric sensing of H 2O 2 after removal of antioxidants with ABTS radical oxidation. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 248:119266. [PMID: 33316653 DOI: 10.1016/j.saa.2020.119266] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/10/2020] [Accepted: 11/18/2020] [Indexed: 05/08/2023]
Abstract
Monitoring and determining H2O2 in many industries, treatment plants and biochemical media is important because of its harmful effects even at low concentrations. This work proposes a redox-based colorimetric sensor for the determination of hydrogen peroxide in the presence of antioxidants which are known interferents causing positive errors. On the other hand, the widely used peroxidase-based methods are interfered by enzyme inhibitors. The proposed method consists of two stages, namely antioxidant removal and H2O2 determination. In the first step, antioxidants were removed simply using ABTS radical (ABTS+) oxidant produced by persulfate. After antioxidant elimination, H2O2 in samples was determined by using the CUPRAC colorimetric sensor. The CUPRAC reagent, copper (II)-neocuproine (Cu(II)-Nc), immobilized on a Nafion persulfonate membrane was used for sensor preparation. The light blue Cu(II)-Nc was reduced by H2O2 to the yellow-orange colored Cu(I)-Nc chelate on the sensor, and the absorbance increase at 450 nm was recorded. The LOD and the LOQ values obtained for H2O2 were 0.33 and 1.10 µM, respectively. The proposed assay was validated in terms of linearity, additivity, precision and recovery. The H2O2 contents of spiked food extracts, synthetic serum and certain commercial products (i.e. food sterilization solution, whitening toothpaste and hair bleaching solution) were found to be comparable to the results of peroxidase-ABTS and titanyl sulfate reference assays. In addition, peroxide-type explosive triacetone triperoxide (TATP) was successfully determined in the presence of amine-type antioxidants. The proposed simple and low-cost assay is not inhibited by environmental agents (heavy metals, pesticides, sulfhydryl agents, etc.) adversely affecting enzymatic methods. It is additionally insensitive to turbidity and colored components of complex samples.
Collapse
Affiliation(s)
- Furkan Burak Şen
- Department of Chemistry, Istanbul University-Cerrahpasa, 34320, Avcilar, Istanbul, Turkey
| | - Mustafa Bener
- Department of Chemistry, Istanbul University-Cerrahpasa, 34320, Avcilar, Istanbul, Turkey
| | - Burcu Bekdeşer
- Department of Chemistry, Istanbul University-Cerrahpasa, 34320, Avcilar, Istanbul, Turkey
| | - Reşat Apak
- Department of Chemistry, Istanbul University-Cerrahpasa, 34320, Avcilar, Istanbul, Turkey.
| |
Collapse
|
11
|
Bilal M, Barceló D, Iqbal HMN. Nanostructured materials for harnessing the power of horseradish peroxidase for tailored environmental applications. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 749:142360. [PMID: 33370916 DOI: 10.1016/j.scitotenv.2020.142360] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 09/06/2020] [Accepted: 09/10/2020] [Indexed: 02/05/2023]
Abstract
High catalytic efficiency, stereoselectivity, and sustainability outcomes of enzymes entice chemists for considering biocatalytic transformations to supplant conventional synthetic routes. As a green and versatile enzyme, horseradish peroxidase (HRP)-based enzymatic catalysis has been widely employed in a range of biological and chemical transformation processes. Nevertheless, like many other enzymes, HRP is likely to denature or destabilize in harsh realistic conditions due to its intrinsic fragile nature, which results in inevitably shortened lifespan and immensely high bioprocess cost. Enzyme immobilization has proven as a prospective strategy for improving their biocatalytic performance in continuous industrial processes. Nanostructured materials with huge accessible surface area, abundant porous structures, exceptional functionalities, and high chemical and mechanical stability have recently garnered intriguing research interests as novel kinds of supporting matrices for HRP immobilization. Many reported immobilized biocatalytic systems have demonstrated high catalytic performances than that to the free form of enzymes, such as enhanced enzyme efficiency, selectivity, stability, and repeatability due to the protective microenvironments provided by nanostructures. This review delineates an updated overview of HRP immobilization using an array of nanostructured materials. Furthermore, the general physicochemical aspects, improved catalytic attributes, and the robust practical implementations of engineered HRP-based catalytic cues are also discussed with suitable examples. To end, concluding remarks, challenges, and worthy suggestions/perspectives for future enzyme immobilization are also given.
Collapse
Affiliation(s)
- Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huaian 223003, China.
| | - Damiá Barceló
- Water and Soil Quality Research Group, Department of Environmental Chemistry, IDAEA-CSIC, C/Jordi Girona 18-26, 08034 Barcelona, Spain; Catalan Institute for Water Research (ICRA), C/Emili Grahit 101, 17003 Girona, Spain; College of Environmental and Resources Sciences, Zhejiang A&F University, Hangzhou 311300, China.
| | - Hafiz M N Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico.
| |
Collapse
|
12
|
Dalkıran B. Amperometric determination of heavy metal using an HRP inhibition biosensor based on ITO nanoparticles-ruthenium (III) hexamine trichloride composite: Central composite design optimization. Bioelectrochemistry 2020; 135:107569. [PMID: 32464529 DOI: 10.1016/j.bioelechem.2020.107569] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 05/13/2020] [Accepted: 05/13/2020] [Indexed: 01/24/2023]
Abstract
A novel horseradish peroxidase (HRP) enzyme inhibition biosensor based on indium tin oxide (ITO) nanoparticles, hexaammineruthenium (III) chloride (RUT), and chitosan (CH) modified glassy carbon electrode (GCE) was developed. The biosensor fabrication process was investigated using scanning electron microscopy, energy-dispersive X-ray spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. The amounts of ITO nanoparticles and RUT were optimized using a 22 central composite design for the optimization of electrode composition. The detection limits were determined as 8 nM, 3 nM, and 1 nM for Pb2+, Ni2+, and Cd2+, respectively. The inhibition calibration curves of the biosensor were found to be within the range of 0.009-0.301 µM with a sensitivity of 11.97 µA µM-1 cm-2 (0.85 µA µM-1) for Pb2+, 0.011-0.368 µM with a sensitivity of 10.84 µA µM-1 cm-2 (0.77 µA µM-1) for Ni2+, and 0.008-0.372 µM with a sensitivity of 10.99 µA µM-1 cm-2 (0.78 µA µM-1) for Cd2+. The type of HRP inhibition by Pb2+, Ni2+ and Cd2+ was investigated by the Dixon and Cornish-Bowden plots. The effects of possible interfering species on the biosensor response were examined. The analysis of Pb2+, Ni2+, and Cd2+ in tap water was demonstrated using the HRP/ITO-RUT-CH/GCE with satisfactory experimental results. The proposed method agreed with the atomic absorption spectrometry results.
Collapse
Affiliation(s)
- Berna Dalkıran
- Ankara University, Faculty of Science, Department of Chemistry, Ankara, Turkey.
| |
Collapse
|
13
|
Montes-Cebrián Y, Álvarez-Carulla A, Colomer-Farrarons J, Puig-Vidal M, Miribel-Català PL. Self-Powered Portable Electronic Reader for Point-of-Care Amperometric Measurements. SENSORS 2019; 19:s19173715. [PMID: 31461956 PMCID: PMC6749422 DOI: 10.3390/s19173715] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 08/23/2019] [Accepted: 08/25/2019] [Indexed: 11/25/2022]
Abstract
In this work, we present a self-powered electronic reader (e-reader) for point-of-care diagnostics based on the use of a fuel cell (FC) which works as a power source and as a sensor. The self-powered e-reader extracts the energy from the FC to supply the electronic components concomitantly, while performing the detection of the fuel concentration. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low power device without needing an external power source. Besides, the custom electronic instrumentation platform can process and display fuel concentration without requiring any type of laboratory equipment. In this study, we present the electronics system in detail and describe all modules that make up the system. Furthermore, we validate the device’s operation with different emulated FCs and sensors presented in the literature. The e-reader can be adjusted to numerous current ranges up to 3 mA, with a 13 nA resolution and an uncertainty of 1.8%. Besides, it only consumes 900 µW in the low power mode of operation, and it can operate with a minimum voltage of 330 mV. This concept can be extended to a wide range of fields, from biomedical to environmental applications.
Collapse
Affiliation(s)
- Yaiza Montes-Cebrián
- Department of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, Martí i Franquès 1, 08028 Barcelona, Spain.
| | - Albert Álvarez-Carulla
- Department of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, Martí i Franquès 1, 08028 Barcelona, Spain
| | - Jordi Colomer-Farrarons
- Department of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, Martí i Franquès 1, 08028 Barcelona, Spain
| | - Manel Puig-Vidal
- Department of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, Martí i Franquès 1, 08028 Barcelona, Spain
| | - Pere Ll Miribel-Català
- Department of Electronics and Biomedical Engineering, Faculty of Physics, University of Barcelona, Martí i Franquès 1, 08028 Barcelona, Spain
| |
Collapse
|
14
|
Chang CC, Lee CH, Wu TH, Chen CP, Chen CY, Lin CW. Reversion of gold nanoparticle aggregates for the detection of Cu 2+ and its application in immunoassays. Analyst 2018; 142:4684-4690. [PMID: 29119996 DOI: 10.1039/c7an01511a] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
A high concentration of copper is a hazardous element to organisms and human health. Although various strategies have been reported for the sensitive detection of copper, a facile and rapid detection of aqueous copper has seldom been addressed to date. Here, we present an easy and accessible colorimetric method to detect Cu2+ using the redispersion of cysteamine-modified gold nanoparticles (CA-AuNPs). Initially, CA caused the aggregation of AuNPs due to the electrostatic interaction and aggregated AuNPs can be regenerated in basic medium. The subsequent addition of Cu2+ to the CA-AuNP dispersion could effectively trigger the aggregation of CA-AuNPs, resulting from the coordination reactivity between the deprotonated CA and Cu2+. This strategy resulted in a detection limit (LOD) of 1.52 μM in drinking water, which is below the U.S. Environmental Protection Agency permissible limit (20 μM). To demonstrate the broad application of CA-AuNPs, we further applied this method to plasmonic immunoassays based on the competitive interaction of Cu2+ between CA-AuNPs and enzymes. The LOD of the Down syndrome biomarker hyperglycosylated human chorionic gonadotropin (H-hCG) was 0.125 mIU mL-1, which is better than that of commercial immunoassays. Importantly, the determination of H-hCG in serum indicates its applicability for the measurement of real samples. Our assay agrees well with the current immunoassay systems and thus it can easily be expanded to a more common sensing platform for different types of biotargets by changing the corresponding antibodies.
Collapse
Affiliation(s)
- Chia-Chen Chang
- Institute of Biomedical Engineering, National Taiwan University, Taipei 106, Taiwan.
| | | | | | | | | | | |
Collapse
|
15
|
Determination of heavy metal ions by an amperometric biosensor based on glucose oxidase immobilized onto single-walled carbon nanotubes/Nile blue nanocomposite. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2018. [DOI: 10.1007/s13738-018-1374-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
16
|
Bucur B, Munteanu FD, Marty JL, Vasilescu A. Advances in Enzyme-Based Biosensors for Pesticide Detection. BIOSENSORS 2018; 8:E27. [PMID: 29565810 PMCID: PMC6022933 DOI: 10.3390/bios8020027] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 03/18/2018] [Accepted: 03/20/2018] [Indexed: 01/10/2023]
Abstract
The intensive use of toxic and remanent pesticides in agriculture has prompted research into novel performant, yet cost-effective and fast analytical tools to control the pesticide residue levels in the environment and food. In this context, biosensors based on enzyme inhibition have been proposed as adequate analytical devices with the added advantage of using the toxicity of pesticides for detection purposes, being more "biologically relevant" than standard chromatographic methods. This review proposes an overview of recent advances in the development of biosensors exploiting the inhibition of cholinesterases, photosynthetic system II, alkaline phosphatase, cytochrome P450A1, peroxidase, tyrosinase, laccase, urease, and aldehyde dehydrogenase. While various strategies have been employed to detect pesticides from different classes (organophosphates, carbamates, dithiocarbamates, triazines, phenylureas, diazines, or phenols), the number of practical applications and the variety of environmental and food samples tested remains limited. Recent advances focus on enhancing the sensitivity and selectivity by using nanomaterials in the sensor assembly and novel mutant enzymes in array-type sensor formats in combination with chemometric methods for data analysis. The progress in the development of solar cells enriched the possibilities for efficient wiring of photosynthetic enzymes on different surfaces, opening new avenues for development of biosensors for photosynthesis-inhibiting herbicides.
Collapse
Affiliation(s)
- Bogdan Bucur
- National Institute of Research and Development for Biological Sciences, Centre of Bioanalysis, 296 Splaiul Independentei, 060031 Bucharest, Romania.
| | - Florentina-Daniela Munteanu
- Faculty of Food Engineering, Tourism and Environmental Protection, "Aurel Vlaicu" University of Arad, Elena Dragoi, No. 2, 310330 Arad, Romania.
| | - Jean-Louis Marty
- BAE Laboratory, Université de Perpignan via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan, France.
| | - Alina Vasilescu
- International Centre of Biodynamics, 1B Intrarea Portocalelor, 060101 Bucharest, Romania.
| |
Collapse
|
17
|
Elsebai B, Ghica ME, Abbas MN, Brett CMA. Catalase based hydrogen peroxide biosensor for mercury determination by inhibition measurements. JOURNAL OF HAZARDOUS MATERIALS 2017; 340:344-350. [PMID: 28728113 DOI: 10.1016/j.jhazmat.2017.07.021] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 07/04/2017] [Accepted: 07/08/2017] [Indexed: 06/07/2023]
Abstract
A new amperometric hydrogen peroxide enzyme inhibition biosensor for the indirect determination of toxic mercury ions, Hg2+, based on catalase immobilized on a glassy carbon electrode surface by cross-linking with glutaraldehyde and bovine serum albumin, is reported. The parameters influencing biosensor performance were optimized, including enzyme loading, the amount of hydrogen peroxide, the applied potential and electrolyte pH. It was shown that the inhibition of catalase by Hg2+ species is irreversible, with a linear inhibition response between 5×10-11 and 5×10-10M. The limit of detection calculated as 10% inhibition was 1.8×10-11M and is the lowest reported until now. Electrochemical impedance spectroscopy was successfully used as a diagnostic of inhibition. Interferences from other heavy metal ions and organic pesticides were evaluated and the inhibition showed very good selectivity towards Hg2+. The method was successfully applied to the determination of mercury ions in different types of water sample.
Collapse
Affiliation(s)
- Basant Elsebai
- Applied Organic Chemistry Department, National Research Centre, Giza, Egypt; Department of Chemistry, Faculty of Sciences and Technology, University of Coimbra, 3004-535 Coimbra, Portugal
| | - Mariana Emilia Ghica
- Department of Chemistry, Faculty of Sciences and Technology, University of Coimbra, 3004-535 Coimbra, Portugal
| | | | - Christopher M A Brett
- Department of Chemistry, Faculty of Sciences and Technology, University of Coimbra, 3004-535 Coimbra, Portugal.
| |
Collapse
|
18
|
Magar HS, Ghica ME, Abbas MN, Brett CMA. Highly Sensitive Choline Oxidase Enzyme Inhibition Biosensor for Lead Ions Based on Multiwalled Carbon Nanotube Modified Glassy Carbon Electrodes. ELECTROANAL 2017. [DOI: 10.1002/elan.201700111] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Hend Samy Magar
- Applied Organic Chemistry Department; National Research Centre; Giza Egypt
- Department of Chemistry, Faculty of Sciences and Technology; University of Coimbra; 3004-535 Coimbra Portugal
| | - Mariana Emilia Ghica
- Department of Chemistry, Faculty of Sciences and Technology; University of Coimbra; 3004-535 Coimbra Portugal
| | | | - Christopher M. A. Brett
- Department of Chemistry, Faculty of Sciences and Technology; University of Coimbra; 3004-535 Coimbra Portugal
| |
Collapse
|
19
|
Fogel R, Limson J. Developing Biosensors in Developing Countries: South Africa as a Case Study. BIOSENSORS-BASEL 2016; 6:bios6010005. [PMID: 26848700 PMCID: PMC4810397 DOI: 10.3390/bios6010005] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 01/23/2016] [Accepted: 01/27/2016] [Indexed: 12/14/2022]
Abstract
A mini-review of the reported biosensor research occurring in South Africa evidences a strong emphasis on electrochemical sensor research, guided by the opportunities this transduction platform holds for low-cost and robust sensing of numerous targets. Many of the reported publications centre on fundamental research into the signal transduction method, using model biorecognition elements, in line with international trends. Other research in this field is spread across several areas including: the application of nanotechnology; the identification and validation of biomarkers; development and testing of biorecognition agents (antibodies and aptamers) and design of electro-catalysts, most notably metallophthalocyanine. Biosensor targets commonly featured were pesticides and metals. Areas of regional import to sub-Saharan Africa, such as HIV/AIDs and tuberculosis diagnosis, are also apparent in a review of the available literature. Irrespective of the targets, the challenge to the effective deployment of such sensors remains shaped by social and economic realities such that the requirements thereof are for low-cost and universally easy to operate devices for field settings. While it is difficult to disentangle the intertwined roles of national policy, grant funding availability and, certainly, of global trends in shaping areas of emphasis in research, most notable is the strong role that nanotechnology, and to a certain extent biotechnology, plays in research regarding biosensor construction. Stronger emphasis on collaboration between scientists in theoretical modelling, nanomaterials application and or relevant stakeholders in the specific field (e.g., food or health monitoring) and researchers in biosensor design may help evolve focused research efforts towards development and deployment of low-cost biosensors.
Collapse
Affiliation(s)
- Ronen Fogel
- Biotechnology Innovation Centre, Rhodes University, P.O. Box 94, Grahamstown 6140, South Africa.
| | - Janice Limson
- Biotechnology Innovation Centre, Rhodes University, P.O. Box 94, Grahamstown 6140, South Africa.
| |
Collapse
|
20
|
Amine A, Arduini F, Moscone D, Palleschi G. Recent advances in biosensors based on enzyme inhibition. Biosens Bioelectron 2015; 76:180-94. [PMID: 26227311 DOI: 10.1016/j.bios.2015.07.010] [Citation(s) in RCA: 114] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2015] [Revised: 06/28/2015] [Accepted: 07/05/2015] [Indexed: 02/07/2023]
Abstract
Enzyme inhibitors like drugs and pollutants are closely correlated to human and environmental health, thus their monitoring is of paramount importance in analytical chemistry. Enzymatic biosensors represent cost-effective, miniaturized and easy to use devices; particularly biosensors based on enzyme inhibition are useful analytical tools for fast screening and monitoring of inhibitors. The present review will highlight the research carried out in the last 9 years (2006-2014) on biosensors based on enzyme inhibition. We underpin the recent advances focused on the investigation in new theoretical approachs and in the evaluation of biosensor performances for reversible and irreversible inhibitors. The use of nanomaterials and microfluidic systems as well as the applications of the various biosensors in real samples is critically reviewed, demonstrating that such biosensors allow the development of useful devices for a fast and reliable alarm system.
Collapse
Affiliation(s)
- A Amine
- Faculty of Sciences and Techniques, University Hassan II of Casablanca, Morocco.
| | - F Arduini
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy; Consorzio Interuniversitario Biostrutture e Biosistemi "INBB", Viale Medaglie d'Oro 305, 00136 Rome, Italy
| | - D Moscone
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy; Consorzio Interuniversitario Biostrutture e Biosistemi "INBB", Viale Medaglie d'Oro 305, 00136 Rome, Italy
| | - G Palleschi
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy; Consorzio Interuniversitario Biostrutture e Biosistemi "INBB", Viale Medaglie d'Oro 305, 00136 Rome, Italy
| |
Collapse
|
21
|
Mahajan AP, Kondawar SB, Mahore RP, Meshram BH, Virutkar PD. Polyaniline/MnO2 Nanocomposites Based Stainless Steel Electrode Modified Enzymatic Urease Biosensor. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.mspro.2015.06.075] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
22
|
Meshram B, Kondawar S, Mahajan A, Mahore R, Burghate D. Urease immobilized polypyrrole/multi-walled carbon nanotubes composite biosensor for heavy metal ions detection. ACTA ACUST UNITED AC 2014. [DOI: 10.1080/22243682.2014.935953] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
23
|
Attar A, Emilia Ghica M, Amine A, Brett CMA. Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements. JOURNAL OF HAZARDOUS MATERIALS 2014; 279:348-355. [PMID: 25080156 DOI: 10.1016/j.jhazmat.2014.07.019] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 07/09/2014] [Accepted: 07/12/2014] [Indexed: 06/03/2023]
Abstract
Amperometric hydrogen peroxide enzyme inhibition biosensors based on horseradish peroxidase (HRP) immobilised on electropolymerised neutral red (NR) or directly on the surface of carbon film electrodes (CFE) have been successfully applied to the determination of toxic Cr(III) and Cr(VI). Parameters influencing the performance of the biosensor including the enzyme immobilisation method, the amount of hydrogen peroxide, applied potential and electrolyte pH were optimised. The inhibition of horseradish peroxidase by the chromium species was studied under the optimised conditions. Results from the quantitative analysis of chromium ions are discussed in terms of detection limit, linear range and sensitivity. The HRP kinetic interactions reveal mixed binding of Cr(III) with I50=3.8μM and inhibition binding constant Ki=11.3μM at HRP/PNR/CFE biosensors and uncompetitive binding of Cr(VI) with I50=3.9μM and Ki=0.78μM at HRP/CFE biosensors in the presence of H2O2 substrate. Interferences from other heavy metal ions were studied and the inhibition show very good selectivity towards Cr(III) and Cr(VI).
Collapse
Affiliation(s)
- Aisha Attar
- Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade de Coimbra, 3004-535 Coimbra, Portugal; Faculty of Science and Techniques, University Hassan II Mohammedia, BP 146, Mohammedia 20650, Morocco
| | - M Emilia Ghica
- Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade de Coimbra, 3004-535 Coimbra, Portugal
| | - Aziz Amine
- Faculty of Science and Techniques, University Hassan II Mohammedia, BP 146, Mohammedia 20650, Morocco.
| | - Christopher M A Brett
- Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade de Coimbra, 3004-535 Coimbra, Portugal.
| |
Collapse
|
24
|
An amperometric biosensor based on horseradish peroxidase immobilized onto maize tassel-multi-walled carbon nanotubes modified glassy carbon electrode for determination of heavy metal ions in aqueous solution. Enzyme Microb Technol 2014; 56:28-34. [DOI: 10.1016/j.enzmictec.2013.12.014] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Revised: 12/16/2013] [Accepted: 12/17/2013] [Indexed: 11/22/2022]
|
25
|
Silwana B, Van Der Horst C, Iwuoha E, Somerset V. Amperometric determination of cadmium, lead, and mercury metal ions using a novel polymer immobilised horseradish peroxidase biosensor system. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2014; 49:1501-1511. [PMID: 25137538 DOI: 10.1080/10934529.2014.937169] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This work was undertaken to develop a novel Pt/PANI-co-PDTDA/HRP biosensor system for environmental applications to investigate the inhibition studies by specific heavy metals, to provide data suitable for kinetic studies and further application of the biosensor to environmental samples. The newly constructed biosensor was compared to the data of the well-researched Pt/PANI/HRP biosensor. Optimised experimental conditions, such as the working pH for the biosensor was evaluated. The functionality of the amperometric enzyme sensor system was demonstrated by measuring the oxidation current of hydrogen peroxide followed by the development of an assay for determination of metal concentration in the presence of selected metal ions of Cd(2+), Pb(2+) and Hg(2+). The detection limits were found to be 8 × 10(-4) μg L(-1) for cadmium, 9.38 × 10(-4) μg L(-1) for lead and 7.89 × 10(-4) μg L(-1) for mercury. The World Health Organisation recommended that the maximum safety level of these metals should not exceed 0.005 mg L(-1) of Cd(2+), 0.01 mg L(-1) of Pb(2+) and 0.001 mg L(-1) of Hg(2+.), respectively. The analytical and detection data for the metals investigated were observed to be lower than concentrations recommended by several bodies including World Health Organisation and Environmental Protection Agencies. Therefore the biosensors developed in this study can be used to screen the presence of these metals in water samples because of its low detection limit. The modes of inhibition of horseradish peroxidase by Pb(2+), Cd(2+) and Hg(2+) as analysed using the double reciprocal plots of the Michaelis-Menten equation was found to be reversible and uncompetitive inhibition. Based on the Km(app) and Imax values for both biosensors the results have shown smaller values. These results also proved that the enzyme modified electrode is valuable and can be deployed for the determination or screening of heavy metals.
Collapse
Affiliation(s)
- Bongiwe Silwana
- a Natural Resources and the Environment (NRE), Council for Scientific and Industrial Research (CSIR) , Stellenbosch , South Africa
| | | | | | | |
Collapse
|