1
|
Eshaghi S, Khaleghi H, Maddahian R. In silico investigation of inhalation condition impacts on hygroscopic growth and deposition of salbutamol sulphate in human airways. Respir Physiol Neurobiol 2024; 326:104271. [PMID: 38703974 DOI: 10.1016/j.resp.2024.104271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 04/09/2024] [Accepted: 04/26/2024] [Indexed: 05/06/2024]
Abstract
The objective of this study is to explore the transport, size growth, and deposition of Salbutamol Sulphate (SS) using Computational Fluid Dynamics (CFD). A CT-based realistic model of human airways from the oral cavity to the 5th generation of the lung was utilized as the computational domain. Four Test Cases (TC) with varying temperature and relative humidity (RH) under two inspiratory waveforms were considered to completely evaluate the impact of inhalation conditions on particle growth. Salbutamol Sulphate (SS) is a β2-adrenergic agonist and has been extensively used for asthma treatment. A monodispersed distribution of SS particles with an initial diameter of 167 nm was considered at the mouth inlet based on pharmaceutical data. Results indicated that inhalation of saturated/supersaturated air (RH>100%) leads to significant hygroscopic growth of SS particles with a factor of 10. In addition, the deposition efficiency of SS particles under the Quick and Deep (QD) inhalation profile was enhanced as the flow temperature and humidity increased. However, the implementation of Slow and Deep (SD) inspiratory waveform revealed that the same particle size growth is achieved in the respiratory system with lower deposition efficiency in the mouth-throat (less than 3%) and tracheobronchial airway (less than 2.18%). For the escaped particles form the right lung, in the SD waveform under TC 3, the maximum particle size distribution was for 600 nm particles with 25% probability. In the left lung, 30% of the particles were increased up to 950 nm in size. For the QD waveform in TC 3 and TC4, the most frequent particles were 800 nm with 36% probability. This holds practical significance in the context of deep lung delivery for asthmatic patients with enhanced deposition efficiency and large particle size. The findings of the present study can contribute to the development of targeted drug delivery strategies for the treatment of pulmonary diseases using hygroscopic dry powder formulations.
Collapse
Affiliation(s)
- Sajad Eshaghi
- Faculty of Mechanical Engineering, Tarbiat Modares University, Jalal-Al-Ahmad, Tehran 14115143, Iran
| | - Hassan Khaleghi
- Faculty of Mechanical Engineering, Tarbiat Modares University, Jalal-Al-Ahmad, Tehran 14115143, Iran
| | - Reza Maddahian
- Faculty of Mechanical Engineering, Tarbiat Modares University, Jalal-Al-Ahmad, Tehran 14115143, Iran.
| |
Collapse
|
2
|
Zhang Y, Almazi JG, Ong HX, Johansen MD, Ledger S, Traini D, Hansbro PM, Kelleher AD, Ahlenstiel CL. Nanoparticle Delivery Platforms for RNAi Therapeutics Targeting COVID-19 Disease in the Respiratory Tract. Int J Mol Sci 2022; 23:2408. [PMID: 35269550 PMCID: PMC8909959 DOI: 10.3390/ijms23052408] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 02/14/2022] [Accepted: 02/18/2022] [Indexed: 02/06/2023] Open
Abstract
Since December 2019, a pandemic of COVID-19 disease, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has rapidly spread across the globe. At present, the Food and Drug Administration (FDA) has issued emergency approval for the use of some antiviral drugs. However, these drugs still have limitations in the specific treatment of COVID-19, and as such, new treatment strategies urgently need to be developed. RNA-interference-based gene therapy provides a tractable target for antiviral treatment. Ensuring cell-specific targeted delivery is important to the success of gene therapy. The use of nanoparticles (NPs) as carriers for the delivery of small interfering RNA (siRNAs) to specific tissues or organs of the human body could play a crucial role in the specific therapy of severe respiratory infections, such as COVID-19. In this review, we describe a variety of novel nanocarriers, such as lipid NPs, star polymer NPs, and glycogen NPs, and summarize the pre-clinical/clinical progress of these nanoparticle platforms in siRNA delivery. We also discuss the application of various NP-capsulated siRNA as therapeutics for SARS-CoV-2 infection, the challenges with targeting these therapeutics to local delivery in the lung, and various inhalation devices used for therapeutic administration. We also discuss currently available animal models that are used for preclinical assessment of RNA-interference-based gene therapy. Advances in this field have the potential for antiviral treatments of COVID-19 disease and could be adapted to treat a range of respiratory diseases.
Collapse
Affiliation(s)
- Yuan Zhang
- Kirby Institute, UNSW, Sydney, NSW 2052, Australia; (Y.Z.); (S.L.); (A.D.K.)
| | - Juhura G. Almazi
- Respiratory Technology, Woolcock Institute of Medical Research, Sydney, NSW 2037, Australia; (J.G.A.); (H.X.O.); (D.T.)
- Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Ryde, NSW 2109, Australia
| | - Hui Xin Ong
- Respiratory Technology, Woolcock Institute of Medical Research, Sydney, NSW 2037, Australia; (J.G.A.); (H.X.O.); (D.T.)
- Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Ryde, NSW 2109, Australia
| | - Matt D. Johansen
- Centre for Inflammation, Faculty of Science, Centenary Institute and University of Technology Sydney, Sydney, NSW 2050, Australia; (M.D.J.); (P.M.H.)
| | - Scott Ledger
- Kirby Institute, UNSW, Sydney, NSW 2052, Australia; (Y.Z.); (S.L.); (A.D.K.)
| | - Daniela Traini
- Respiratory Technology, Woolcock Institute of Medical Research, Sydney, NSW 2037, Australia; (J.G.A.); (H.X.O.); (D.T.)
- Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Ryde, NSW 2109, Australia
| | - Philip M. Hansbro
- Centre for Inflammation, Faculty of Science, Centenary Institute and University of Technology Sydney, Sydney, NSW 2050, Australia; (M.D.J.); (P.M.H.)
| | - Anthony D. Kelleher
- Kirby Institute, UNSW, Sydney, NSW 2052, Australia; (Y.Z.); (S.L.); (A.D.K.)
| | | |
Collapse
|
3
|
Xu C, Zheng X, Shen S. A numerical study of the effects of ambient temperature and humidity on the particle growth and deposition in the human airway. ENVIRONMENTAL RESEARCH 2021; 200:111751. [PMID: 34303679 DOI: 10.1016/j.envres.2021.111751] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 06/25/2021] [Accepted: 07/21/2021] [Indexed: 06/13/2023]
Abstract
A numerical study was conducted on the effects of ambient temperature and humidity on the transportation of sodium chloride particles (100 nm-1 μm) in a human airway model ranging from the nasal cavity to bronchi. A mucus-tissue structure was adopted to model the mass and heat transfer on the airway surface boundary. The temperature and humidity distributions of the respiratory flow were calculated and then the interaction between the particle and water vapor was further analyzed. It was predicted that the particle size grew to the ratio of 5-6 under subsaturation conditions because of hygroscopicity, which shifted the deposition efficiency in opposite directions on dependence of the initial particle size. However, the particles could be drastically raised to 40 times of the initial 100 nm diameter if the supersaturation-induced condensation was established, that was prone to occur under the cold-dry condition, and consequently promoted the deposition significantly. Such behavior might effectively contribute to the revitalized coronavirus disease 2019 (COVID-19) pandemic in addition to the more active virus itself in winter.
Collapse
Affiliation(s)
- Chang Xu
- Department of Engineering Physics, Tsinghua University, Beijing, China; Beijing Key Laboratory of City Integrated Emergency Response Science, Beijing, China
| | - Xin Zheng
- Department of Engineering Physics, Tsinghua University, Beijing, China.
| | - Shifei Shen
- Department of Engineering Physics, Tsinghua University, Beijing, China; Anhui Province Key Laboratory of Human Safety, Hefei, Anhui, China
| |
Collapse
|
4
|
Howe C, Momin MAM, Farkas DR, Bonasera S, Hindle M, Longest PW. Advancement of the Infant Air-Jet Dry Powder Inhaler (DPI): Evaluation of Different Positive-Pressure Air Sources and Flow Rates. Pharm Res 2021; 38:1615-1632. [PMID: 34462876 DOI: 10.1007/s11095-021-03094-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 08/05/2021] [Indexed: 11/28/2022]
Abstract
PURPOSE In order to improve the delivery of dry powder aerosol formulations to the lungs of infants, this study implemented an infant air-jet platform and explored the effects of different air sources, flow rates, and pulmonary mechanics on aerosolization performance and aerosol delivery through a preterm nose-throat (NT) in vitro model. METHODS The infant air-jet platform was actuated with a positive-pressure air source that delivered the aerosol and provided a full inhalation breath. Three different air sources were developed to provide highly controllable positive-pressure air actuations (using actuation volumes of ~10 mL for the preterm model). While providing different flow waveform shapes, the three air sources were calibrated to produce the same flow rate magnitude (Q90: 90th percentile of flow rate). Multiple air-jet DPI designs were coupled with the air sources and evaluated with a model spray-dried excipient enhanced growth formulation. RESULTS Compared to other designs, the D1-Single air-jet DPI provided improved performance with low variability across all three air sources. With the tested D1-Single air-jet and Timer air source, reducing the flow rate from 4 to 1.7 L/min marginally decreased the aerosol size and significantly increased the lung delivery efficiency above 50% of the loaded dose. These results were not impacted by the presence of downstream pulmonary mechanics (resistance and compliance model). CONCLUSIONS The selected design was capable of providing an estimated >50% lung delivery efficiency of a model spray-dried formulation and was not influenced by the air source, thereby enabling greater flexibility for platform deployment in different environments.
Collapse
Affiliation(s)
- Connor Howe
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA, 23284-3015, USA
| | - Mohammad A M Momin
- Department of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA, 23298-0533, USA
| | - Dale R Farkas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA, 23284-3015, USA
| | - Serena Bonasera
- Department of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA, 23298-0533, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA, 23298-0533, USA
| | - P Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA, 23284-3015, USA. .,Department of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA, 23298-0533, USA.
| |
Collapse
|
5
|
Diveky ME, Gleichweit MJ, Roy S, Signorell R. Shining New Light on the Kinetics of Water Uptake by Organic Aerosol Particles. J Phys Chem A 2021; 125:3528-3548. [PMID: 33739837 DOI: 10.1021/acs.jpca.1c00202] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The uptake of water vapor by various organic aerosols is important in a number of applications ranging from medical delivery of pharmaceutical aerosols to cloud formation in the atmosphere. The coefficient that describes the probability that the impinging gas-phase molecule sticks to the surface of interest is called the mass accommodation coefficient, αM. Despite the importance of this coefficient for the description of water uptake kinetics, accurate values are still lacking for many systems. In this Feature Article, we present various experimental techniques that have been evoked in the literature to study the interfacial transport of water and discuss the corresponding strengths and limitations. This includes our recently developed technique called photothermal single-particle spectroscopy (PSPS). The PSPS technique allows for a retrieval of αM values from three independent, yet simultaneous measurements operating close to equilibrium, providing a robust assessment of interfacial mass transport. We review the currently available data for αM for water on various organics and discuss the few studies that address the temperature and relative humidity dependence of αM for water on organics. The knowledge of the latter, for example, is crucial to assess the water uptake kinetics of organic aerosols in the Earth's atmosphere. Finally, we argue that PSPS might also be a viable method to better restrict the αM value for water on liquid water.
Collapse
Affiliation(s)
- Matus E Diveky
- Laboratory of Physical Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 2, CH-8093 Zürich, Switzerland
| | - Michael J Gleichweit
- Laboratory of Physical Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 2, CH-8093 Zürich, Switzerland
| | - Sandra Roy
- Laboratory of Physical Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 2, CH-8093 Zürich, Switzerland
| | - Ruth Signorell
- Laboratory of Physical Chemistry, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 2, CH-8093 Zürich, Switzerland
| |
Collapse
|
6
|
Lavanya MN, Preethi R, Moses JA, Anandharamakrishnan C. Aerosol-based Pulmonary Delivery of Therapeutic Molecules from Food Sources: Delivery Mechanism, Research Trends, and the Way Forward. FOOD REVIEWS INTERNATIONAL 2021. [DOI: 10.1080/87559129.2021.1888971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- M. N. Lavanya
- Computational Modeling and Nanoscale Processing Unit, Indian Institute of Food Processing Technology (IIFPT), Ministry of Food Processing Industries, Govt. Of India, India
| | - R. Preethi
- Computational Modeling and Nanoscale Processing Unit, Indian Institute of Food Processing Technology (IIFPT), Ministry of Food Processing Industries, Govt. Of India, India
| | - J. A. Moses
- Computational Modeling and Nanoscale Processing Unit, Indian Institute of Food Processing Technology (IIFPT), Ministry of Food Processing Industries, Govt. Of India, India
| | - C. Anandharamakrishnan
- Computational Modeling and Nanoscale Processing Unit, Indian Institute of Food Processing Technology (IIFPT), Ministry of Food Processing Industries, Govt. Of India, India
| |
Collapse
|
7
|
Rajaraman PK, Choi J, Hoffman EA, O'Shaughnessy PT, Choi S, Delvadia R, Babiskin A, Walenga R, Lin CL. Transport and deposition of hygroscopic particles in asthmatic subjects with and without airway narrowing. JOURNAL OF AEROSOL SCIENCE 2020; 146:105581. [PMID: 32346183 PMCID: PMC7187883 DOI: 10.1016/j.jaerosci.2020.105581] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 04/21/2020] [Accepted: 04/24/2020] [Indexed: 05/30/2023]
Abstract
This study numerically investigates the effect of hygroscopicity on transport and deposition of particles in severe asthmatic lungs with distinct airway structures. The study human subjects were selected from two imaging-based severe asthmatic clusters with one characterized by non-constricted airways and the other by constricted airways in the lower left lobe (LLL). We compared the deposition fractions of sodium chloride (NaCl) particles with a range of aerodynamic diameters (1-8 μm) in cluster archetypes under conditions with and without hygroscopic growth. The temperature and water vapor distributions in the airways were simulated with an airway wall boundary condition that accounts for variable temperature and water vapor evaporation at the interface between the lumen and the airway surface liquid layer. On average, the deposition fraction increased by about 6% due to hygroscopic particle growth in the cluster subjects with constricted airways, while it increased by only about 0.5% in those with non-constricted airways. The effect of particle growth was most significant for particles with an initial diameter of 2 μm in the cluster subjects with constricted airways. The effect diminished with increasing particle size, especially for particles with an initial diameter larger than 4 μm. This suggests the necessity to differentiate asthmatic subjects by cluster in engineering the aerosol size for tailored treatment. Specifically, the treatment of severe asthmatic subjects who have constricted airways with inhalation aerosols may need submicron-sized hygroscopic particles to compensate for particle growth, if one targets for delivering to the peripheral region. These results could potentially inform the choice of particle size for inhalational drug delivery in a cluster-specific manner.
Collapse
Affiliation(s)
- Prathish K. Rajaraman
- Department of Mechanical Engineering, The University of Iowa, Iowa City, IA, USA
- IIHR-Hydroscience and Engineering, The University of Iowa, Iowa City, IA, USA
| | - Jiwoong Choi
- Department of Mechanical Engineering, The University of Iowa, Iowa City, IA, USA
- IIHR-Hydroscience and Engineering, The University of Iowa, Iowa City, IA, USA
| | - Eric A. Hoffman
- Department of Radiology, The University of Iowa, Iowa City, IA, USA
| | | | - Sanghun Choi
- School of Mechanical Engineering, Kyungpook National University, Daegu, 41566, Republic of Korea
| | - Renishkumar Delvadia
- Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Andrew Babiskin
- Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Ross Walenga
- Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Ching-Long Lin
- Department of Mechanical Engineering, The University of Iowa, Iowa City, IA, USA
- IIHR-Hydroscience and Engineering, The University of Iowa, Iowa City, IA, USA
| |
Collapse
|
8
|
O’Shaughnessy PT, LeBlanc L, Pratt A, Altmaier R, Rajaraman PK, Walenga R, Lin CL. Assessment and Validation of a Hygroscopic Growth Model with Different Water Activity Estimation Methods. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2020; 54:1169-1182. [PMID: 33100458 PMCID: PMC7577510 DOI: 10.1080/02786826.2020.1763247] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 04/21/2020] [Accepted: 04/21/2020] [Indexed: 05/21/2023]
Abstract
Hygroscopic growth models are currently of interest as aids for targeting the deposition of inhaled drug particles in preferred areas of the lung that will maximize their pharmaceutical effect. Mathematical models derived to estimate hygroscopic growth over time have been previously developed but have not been thoroughly validated. For this study, model validation involved a comparison of modeled values to measured values when the growing droplet had reached equilibrium. A second validation process utilized a novel system to measure the growth of a droplet on a microscope coverslip relative to modeled values when the droplet is undergoing the initial rapid growth phase. Various methods currently used to estimate the water activity of the growing droplet, which influences the droplet growth rate, were also compared. Results indicated that a form of the hygroscopic growth model that utilizes coupled-differential equations to estimate droplet diameter and temperature over time was valid throughout droplet growth until it reached its equilibrium size. Accuracy was enhanced with the use of a polynomial expression to estimate water activity relative to the use of a simplified estimate of water activity based on Raoult's Law. Model accuracy was also improved when constraining the film of salt solution surrounding the dissolving salt core at saturation.
Collapse
Affiliation(s)
| | - Lawrence LeBlanc
- Mechanical Engineering, University of Iowa, Iowa City, Iowa, USA
| | - Alessandra Pratt
- Occupational & Environmental Health, University of Iowa, Iowa City, Iowa, USA
| | - Ralph Altmaier
- Occupational & Environmental Health, University of Iowa, Iowa City, Iowa, USA
| | | | - Ross Walenga
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Ching-Long Lin
- Mechanical Engineering, University of Iowa, Iowa City, Iowa, USA
| |
Collapse
|
9
|
Fröhlich E. Biological Obstacles for Identifying In Vitro- In Vivo Correlations of Orally Inhaled Formulations. Pharmaceutics 2019; 11:E316. [PMID: 31284402 PMCID: PMC6680885 DOI: 10.3390/pharmaceutics11070316] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2019] [Revised: 06/15/2019] [Accepted: 07/02/2019] [Indexed: 12/26/2022] Open
Abstract
Oral inhalation of drugs is the classic therapy of obstructive lung diseases. In contrast to the oral route, the link between in vitro and in vivo findings is less well defined and predictive models and parameters for in vitro-in vivo correlations are missing. Frequently used in vitro models and problems in obtaining in vivo values to establish such models and to identify the action of formulations in vivo are discussed. It may be concluded that major obstacles to link in vitro parameters on in vivo action include lack of treatment adherence and incorrect use of inhalers by patients, variation in inhaler performance, changes by humidity, uncertainties about lung deposition, and difficulties to measure drug levels in epithelial lining fluid and tissue. Physiologically more relevant in vitro models, improvement in inhaler performance, and better techniques for in vivo measurements may help to better understand importance and interactions between individual in vitro parameters in pulmonary delivery.
Collapse
Affiliation(s)
- Eleonore Fröhlich
- Center for Medical Research, Medical University of Graz, 8010 Graz, Austria.
- Research Center Pharmaceutical Engineering GmbH, 8010 Graz, Austria.
| |
Collapse
|
10
|
Moon C, Smyth HDC, Watts AB, Williams RO. Delivery Technologies for Orally Inhaled Products: an Update. AAPS PharmSciTech 2019; 20:117. [PMID: 30783904 DOI: 10.1208/s12249-019-1314-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 01/18/2019] [Indexed: 12/22/2022] Open
Abstract
Orally inhaled products have well-known benefits. They allow for effective local administration of many drugs for the treatment of pulmonary disease, and they allow for rapid absorption and avoidance of first-pass metabolism of several systemically acting drugs. Several challenges remain, however, such as dosing limitations, low and variable deposition of the drug in the lungs, and high drug deposition in the oropharynx region. These challenges have stimulated the development of new delivery technologies. Both formulation improvements and new device technologies have been developed through an improved understanding of the mechanisms of aerosolization and lung deposition. These new advancements in formulations have enabled improved aerosolization by controlling particle properties such as density, size, shape, and surface energy. New device technologies emerging in the marketplace focus on minimizing patient errors, expanding the range of inhaled drugs, improving delivery efficiency, increasing dose consistency and dosage levels, and simplifying device operation. Many of these new technologies have the potential to improve patient compliance. This article reviews how new delivery technologies in the form of new formulations and new devices enhance orally inhaled products.
Collapse
|
11
|
Short DZ, Vu D, Durbin TD, Karavalakis G, Asa-Awuku A. Components of Particle Emissions from Light-Duty Spark-Ignition Vehicles with Varying Aromatic Content and Octane Rating in Gasoline. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:10682-10691. [PMID: 26244891 DOI: 10.1021/acs.est.5b03138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Typical gasoline consists of varying concentrations of aromatic hydrocarbons and octane ratings. However, their impacts on particulate matter (PM) such as black carbon (BC) and water-soluble and insoluble particle compositions are not well-defined. This study tests seven 2012 model year vehicles, which include one port fuel injection (PFI) configured hybrid vehicle, one PFI vehicle, and six gasoline direct injection (GDI) vehicles. Each vehicle was driven on the Unified transient testing cycle (UC) using four different fuels. Three fuels had a constant octane rating of 87 with varied aromatic concentrations at 15%, 25%, and 35%. A fourth fuel with higher octane rating, 91, contained 35% aromatics. BC, PM mass, surface tension, and water-soluble organic mass (WSOM) fractions were measured. The water-insoluble mass (WIM) fraction of the vehicle emissions was estimated. Increasing fuel aromatic content increases BC emission factors (EFs) of transient cycles. BC concentrations were higher for the GDI vehicles than the PFI and hybrid vehicles, suggesting a potential climate impact for increased GDI vehicle production. Vehicle steady-state testing showed that the hygroscopicity of PM emissions at high speeds (70 mph; κ > 1) are much larger than emissions at low speeds (30 mph; κ < 0.1). Iso-paraffin content in the fuels was correlated to the decrease in WSOM emissions. Both aromatic content and vehicle speed increase the amount of hygroscopic material found in particle emissions.
Collapse
Affiliation(s)
- Daniel Z Short
- Department of Chemical and Environmental Engineering, University of California- Riverside , 900 University Ave., Riverside 92507, California, United States
- College of Engineering- Center for Environmental Research and Technology, University of California- Riverside , 1084 Columbia Ave., Riverside 92521, California, United States
| | - Diep Vu
- Department of Chemical and Environmental Engineering, University of California- Riverside , 900 University Ave., Riverside 92507, California, United States
- College of Engineering- Center for Environmental Research and Technology, University of California- Riverside , 1084 Columbia Ave., Riverside 92521, California, United States
| | - Thomas D Durbin
- Department of Chemical and Environmental Engineering, University of California- Riverside , 900 University Ave., Riverside 92507, California, United States
- College of Engineering- Center for Environmental Research and Technology, University of California- Riverside , 1084 Columbia Ave., Riverside 92521, California, United States
| | - Georgios Karavalakis
- Department of Chemical and Environmental Engineering, University of California- Riverside , 900 University Ave., Riverside 92507, California, United States
- College of Engineering- Center for Environmental Research and Technology, University of California- Riverside , 1084 Columbia Ave., Riverside 92521, California, United States
| | - Akua Asa-Awuku
- Department of Chemical and Environmental Engineering, University of California- Riverside , 900 University Ave., Riverside 92507, California, United States
- College of Engineering- Center for Environmental Research and Technology, University of California- Riverside , 1084 Columbia Ave., Riverside 92521, California, United States
| |
Collapse
|
12
|
Tian G, Hindle M, Longest PW. Targeted Lung Delivery of Nasally Administered Aerosols. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2014; 48:434-449. [PMID: 24932058 PMCID: PMC4051279 DOI: 10.1080/02786826.2014.887829] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Using the nasal route to deliver pharmaceutical aerosols to the lungs has a number of advantages including co-administration during non-invasive ventilation. The objective of this study was to evaluate the growth and deposition characteristics of nasally administered aerosol throughout the conducting airways based on delivery with streamlined interfaces implementing two forms of controlled condensational growth technology. Characteristic conducting airways were considered including a nose-mouth-throat (NMT) geometry, complete upper tracheobronchial (TB) model through the third bifurcation (B3), and stochastic individual path (SIP) model to the terminal bronchioles (B15). Previously developed streamlined nasal cannula interfaces were used for the delivery of submicrometer particles using either enhanced condensational growth (ECG) or excipient enhanced growth (EEG) techniques. Computational fluid dynamics (CFD) simulations predicted aerosol transport, growth and deposition for a control (4.7 μm) and three submicrometer condensational aerosols with budesonide as a model insoluble drug. Depositional losses with condensational aerosols in the cannula and NMT were less than 5% of the initial dose, which represents an order-of-magnitude reduction compared to the control. The condensational growth techniques increased the TB dose by a factor of 1.1-2.6x, delivered at least 70% of the dose to the alveolar region, and produced final aerosol sizes ≥2.5 μm. Compared to multiple commercial orally inhaled products, the nose-to-lung delivery approach increased dose to the biologically important lower TB region by factors as large as 35x. In conclusion, nose-to-lung delivery with streamlined nasal cannulas and condensational aerosols was highly efficient and targeted deposition to the lower TB and alveolar regions.
Collapse
Affiliation(s)
- Geng Tian
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, USA
| | - P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, USA
- Address correspondence to: P. Worth Longest, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, USA.
| |
Collapse
|
13
|
Tian G, Longest PW, Li X, Hindle M. Targeting aerosol deposition to and within the lung airways using excipient enhanced growth. J Aerosol Med Pulm Drug Deliv 2013; 26:248-65. [PMID: 23286828 PMCID: PMC3826577 DOI: 10.1089/jamp.2012.0997] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2012] [Accepted: 10/10/2012] [Indexed: 10/27/2022] Open
Abstract
BACKGROUND Previous studies have characterized the size increase of combination submicrometer particles composed of a drug and hygroscopic excipient when exposed to typical airway thermodynamic conditions. The objective of this study was to determine the deposition and size increase characteristics of excipient enhanced growth (EEG) aerosols throughout the tracheobronchial (TB) airways and to evaluate the potential for targeted delivery. METHODS Submicrometer particles composed of a poorly water-soluble drug (insulin) and hygroscopic excipient (sodium chloride) were considered at drug:excipient mass ratios of 50:50 and 25:75. A previously validated computational fluid dynamics model was used to predict aerosol size increase and deposition in characteristic geometries of the mouth-throat (MT), upper TB airways through the third bifurcation (B3), and remaining TB airways through B15. Additional validation experiments were also performed for albuterol sulfate:mannitol particles. Both growth of combination particles and deposition are reported throughout the conducting airways for characteristic slow and deep (SD) and quick and deep (QD) inhalations. RESULTS For all EEG cases considered, MT deposition was less than 1% of the drug dose, which is at least one order of magnitude lower than with state-of-the-art and conventional inhalers. Final aerosol sizes exiting the TB region and entering the alveolar airways were all greater than 3 μm. For SD inhalation, deposition fractions of 20% were achieved in the lower TB region of B8-B15, which is a factor of 20-30×higher than conventional delivery devices. With QD inhalation, maximum alveolar delivery of 90% was observed. CONCLUSIONS Increasing the dose delivered to the lower TB region by a factor of 20-30×or achieving 90% delivery to the alveolar airways was considered effective aerosol targeting compared with conventional devices. The trend of higher flow rates resulting in better alveolar delivery of aerosols is unique to EEG and may be used to design highly efficient dry powder inhalers.
Collapse
Affiliation(s)
- Geng Tian
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284
| | - P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA 23284
| | - Xiang Li
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA 23284
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA 23284
| |
Collapse
|
14
|
Nahar K, Gupta N, Gauvin R, Absar S, Patel B, Gupta V, Khademhosseini A, Ahsan F. In vitro, in vivo and ex vivo models for studying particle deposition and drug absorption of inhaled pharmaceuticals. Eur J Pharm Sci 2013; 49:805-18. [PMID: 23797056 DOI: 10.1016/j.ejps.2013.06.004] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2013] [Revised: 05/03/2013] [Accepted: 06/07/2013] [Indexed: 01/14/2023]
Abstract
Delivery of therapeutic agents via the pulmonary route has gained significant attention over the past few decades because this route of administration offers multiple advantages over traditional routes that include localized action, non-invasive nature and favorable lung-to-plasma ratio. However, assessment of post administration behavior of inhaled pharmaceuticals-such as deposition of particles over the respiratory airways, interaction with the respiratory fluid and movement across the air-blood barrier-is challenging because the lung is a very complex organs that is composed of airways with thousands of bifurcations with variable diameters. Thus, much effort has been put forward to develop models that mimic human lungs and allow evaluation of various pharmaceutical and physiological factors that influence the deposition and absorption profiles of inhaled formulations. In this review, we sought to discuss in vitro, in vivo and ex vivo models that have been extensively used to study the behaviors of airborne particles in the lungs and determine the absorption of drugs after pulmonary administration. We have provided a summary of lung cast models, cascade impactors, noninvasive imaging, intact animals, cell culture and isolated perfused lung models as tools to evaluate the distribution and absorption of inhaled particles. We have also outlined the limitations of currently used models and proposed future studies to enhance the reproducibility of these models.
Collapse
Affiliation(s)
- Kamrun Nahar
- Department of Pharmaceutical Sciences, School of Pharmacy, Texas Tech University Health Sciences Center, 1300 Coulter Drive, Amarillo, TX 79106, USA
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Longest PW, Walenga RL, Son YJ, Hindle M. High-efficiency generation and delivery of aerosols through nasal cannula during noninvasive ventilation. J Aerosol Med Pulm Drug Deliv 2012; 26:266-79. [PMID: 23273243 DOI: 10.1089/jamp.2012.1006] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Previous studies have demonstrated the delivery of pharmaceutical aerosols through nasal cannula and the feasibility of enhanced condensational growth (ECG) with a nasal interface. The objectives of this study were to develop a device for generating submicrometer aerosols with minimal depositional loss in the formation process and to improve aerosol delivery efficiencies through nasal cannulas. METHODS A combination of in vitro experiments and computational fluid dynamics (CFD) simulations that used the strengths of each method was applied. Aerosols were formed using a conventional mesh nebulizer, mixed with ventilation gas, and heated to produce submicrometer sizes. An improved version of the mixer and heater unit was developed based on CFD simulations, and performance was verified with experiments. Aerosol delivery was considered through a commercial large-bore adult cannula, a divided (D) design for use with ECG, and a divided and streamlined (DS) design. RESULTS The improved mixer design reduced the total deposition fraction (DF) of drug within the mixer by a factor of 3 compared with an initial version, had a total DF of approximately 10%, and produced submicrometer aerosols at flow rates of 10 and 15 L/min. Compared with the commercial and D designs for submicrometer aerosols, the DS cannula reduced depositional losses by a factor of 2-3 and retained only approximately 5% or less of the nebulized dose at all flow rates considered. For conventional-sized aerosols (3.9 and 4.7 μm), the DS device provided delivery efficiencies of approximately 80% and above at flow rates of 2-15 L/min. CONCLUSIONS Submicrometer aerosols can be formed using a conventional mesh nebulizer and delivered through a nasal cannula with total delivery efficiencies of 80-90%. Streamlining the nasal cannula significantly improved the delivery efficiency of both submicrometer and micrometer aerosols; however, use of submicrometer particles with ECG delivery resulted in overall lower depositional losses.
Collapse
Affiliation(s)
- P Worth Longest
- 1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, VA 23284
| | | | | | | |
Collapse
|
16
|
Longest PW, Spence BM, Holbrook LT, Mossi KM, Son YJ, Hindle M. Production of Inhalable Submicrometer Aerosols from Conventional Mesh Nebulizers for Improved Respiratory Drug Delivery. JOURNAL OF AEROSOL SCIENCE 2012; 51:66-80. [PMID: 22707794 PMCID: PMC3374487 DOI: 10.1016/j.jaerosci.2012.04.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Submicrometer and nanoparticle aerosols may significantly improve the delivery efficiency, dissolution characteristics, and bioavailability of inhaled pharmaceuticals. The objective of this study was to explore the formation of submicrometer and nanometer aerosols from mesh nebulizers suitable for respiratory drug delivery using experiments and computational fluid dynamics (CFD) modeling. Mesh nebulizers were coupled with add-on devices to promote aerosol drying and the formation of submicrometer particles, as well as to control the inhaled aerosol temperature and relative humidity. Cascade impaction experiments were used to determine the initial mass median aerodynamic diameters of 0.1% albuterol aerosols produced by the AeroNeb commercial (4.69 μm) and lab (3.90 μm) nebulizers and to validate the CFD model in terms of droplet evaporation. Through an appropriate selection of flow rates, nebulizers, and model drug concentrations, submicrometer and nanometer aerosols could be formed with the three devices considered. Based on CFD simulations, a wire heated design was shown to overheat the airstream producing unsafe conditions for inhalation if the aerosol was not uniformly distributed in the tube cross-section or if the nebulizer stopped producing droplets. In comparison, a counter-flow heated design provided sufficient thermal energy to produce submicrometer particles, but also automatically limited the maximum aerosol outlet temperature based on the physics of heat transfer. With the counter-flow design, submicrometer aerosols were produced at flow rates of 5, 15, and 30 LPM, which may be suitable for various forms of oral and nasal aerosol delivery. Thermodynamic conditions of the aerosol stream exiting the counter-flow design were found be in a range of 21-45 °C with relative humidity greater than 40% in some cases, which was considered safe for direct inhalation and advantageous for condensational growth delivery.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical Engineering Virginia Commonwealth University, Richmond, VA
- Department of Pharmaceutics Virginia Commonwealth University, Richmond, VA
| | - Benjamin M. Spence
- Department of Mechanical Engineering Virginia Commonwealth University, Richmond, VA
| | - Landon T. Holbrook
- Department of Mechanical Engineering Virginia Commonwealth University, Richmond, VA
| | - Karla M. Mossi
- Department of Mechanical Engineering Virginia Commonwealth University, Richmond, VA
| | - Yoen-Ju Son
- Department of Pharmaceutics Virginia Commonwealth University, Richmond, VA
| | - Michael Hindle
- Department of Pharmaceutics Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
17
|
Longest PW, Tian G, Li X, Son YJ, Hindle M. Performance of combination drug and hygroscopic excipient submicrometer particles from a softmist inhaler in a characteristic model of the airways. Ann Biomed Eng 2012; 40:2596-610. [PMID: 22820981 DOI: 10.1007/s10439-012-0616-2] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2012] [Accepted: 07/04/2012] [Indexed: 12/20/2022]
Abstract
Excipient enhanced growth (EEG) of inhaled submicrometer pharmaceutical aerosols is a recently proposed method intended to significantly reduce extrathoracic deposition and improve lung delivery. The objective of this study was to evaluate the size increase of combination drug and hygroscopic excipient particles in a characteristic model of the airways during inhalation using both in vitro experiments and computational fluid dynamic (CFD) simulations. The airway model included a characteristic mouth-throat (MT) and upper tracheobronchial (TB) region through the third bifurcation and was enclosed in a chamber geometry used to simulate the thermodynamic conditions of the lungs. Both in vitro results and CFD simulations were in close agreement and indicated that EEG delivery of combination submicrometer particles could nearly eliminate MT deposition for inhaled pharmaceutical aerosols. Compared with current inhalers, the proposed delivery approach represents a 1-2 order of magnitude reduction in MT deposition. Transient inhalation was found to influence the final size of the aerosol based on changes in residence times and relative humidity values. Aerosol sizes following EEG when exiting the chamber (2.75-4.61 μm) for all cases of initial submicrometer combination particles were equivalent to or larger than many conventional pharmaceutical aerosols that frequently have MMADs in the range of 2-3 μm.
Collapse
Affiliation(s)
- P Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, USA.
| | | | | | | | | |
Collapse
|
18
|
|
19
|
Fernández Tena A, Casan Clarà P. Deposition of inhaled particles in the lungs. Arch Bronconeumol 2012; 48:240-6. [PMID: 22464044 DOI: 10.1016/j.arbres.2012.02.003] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Accepted: 02/01/2012] [Indexed: 10/28/2022]
Abstract
Inhaled medication is the first-line treatment of diseases such as asthma or chronic obstructive pulmonary disease. Its effectiveness is related to the amount of drug deposited beyond the oropharyngeal region, the place where the deposit occurs and its distribution (uniform or not). It is also important to consider the size of the inhaled particles, the breathing conditions, the geometry of the airways and the mucociliary clearance mechanisms. Currently, mathematical models are being applied to describe the deposition of inhaled drugs based on the size of the particles, the inspiratory flow and the anatomical distribution of the bronchial tree. The deposition of particles in the small airways gets maximum attention from pharmaceutical companies and is of great interest as it is related with a better control in patients receiving these drugs.
Collapse
Affiliation(s)
- Ana Fernández Tena
- Instituto Nacional de Silicosis, Hospital Universitario Central de Asturias, Facultad de Medicina, Universidad de Oviedo, España
| | | |
Collapse
|
20
|
Longest PW, Holbrook LT. In silico models of aerosol delivery to the respiratory tract - development and applications. Adv Drug Deliv Rev 2012; 64:296-311. [PMID: 21640772 PMCID: PMC3258464 DOI: 10.1016/j.addr.2011.05.009] [Citation(s) in RCA: 115] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Revised: 05/12/2011] [Accepted: 05/19/2011] [Indexed: 10/18/2022]
Abstract
This review discusses the application of computational models to simulate the transport and deposition of inhaled pharmaceutical aerosols from the site of particle or droplet formation to deposition within the respiratory tract. Traditional one-dimensional (1-D) whole-lung models are discussed briefly followed by a more in-depth review of three-dimensional (3-D) computational fluid dynamics (CFD) simulations. The review of CFD models is organized into sections covering transport and deposition within the inhaler device, the extrathoracic (oral and nasal) region, conducting airways, and alveolar space. For each section, a general review of significant contributions and advancements in the area of simulating pharmaceutical aerosols is provided followed by a more in-depth application or case study that highlights the challenges, utility, and benefits of in silico models. Specific applications presented include the optimization of an existing spray inhaler, development of charge-targeted delivery, specification of conditions for optimal nasal delivery, analysis of a new condensational delivery approach, and an evaluation of targeted delivery using magnetic aerosols. The review concludes with recommendations on the need for more refined model validations, use of a concurrent experimental and CFD approach for developing aerosol delivery systems, and development of a stochastic individual path (SIP) model of aerosol transport and deposition throughout the respiratory tract.
Collapse
Affiliation(s)
- P Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, United States.
| | | |
Collapse
|
21
|
Hindle M, Longest PW. Condensational growth of combination drug-excipient submicrometer particles for targeted high-efficiency pulmonary delivery: evaluation of formulation and delivery device. J Pharm Pharmacol 2012; 64:1254-63. [PMID: 22881438 DOI: 10.1111/j.2042-7158.2012.01476.x] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
OBJECTIVES The objective of this study was to investigate the in-vitro particle-size growth of combination drug and excipient submicrometer aerosols generated from a series of formulations and two aerosol delivery devices. METHODS Submicrometer combination drug and excipient particles were generated experimentally using both the capillary aerosol generator and the Respimat inhaler. Budesonide and albuterol sulfate were used as model drugs and were formulated with sodium chloride, citric acid and mannitol as excipients in various ratios. Aerosol growth was evaluated in-vitro in a coiled-tube geometry designed to provide residence times and thermodynamic conditions consistent with the airways. KEY FINDINGS Submicrometer combination drug : excipient aerosols when exposed to simulated respiratory conditions increased to micrometer size suitable for pulmonary deposition. It was possible to control the aerosol growth ratio by altering: (1) the hygroscopic excipient, (2) the drug : excipient ratio and (3) the drug. The applicability of this approach was demonstrated using the capillary aerosol generator and the Respimat inhaler. CONCLUSIONS The enhanced excipient growth approach may enable the delivery of submicrometer aerosol particles that increase in size within the airways and result in high percentages of pulmonary deposition.
Collapse
Affiliation(s)
- Michael Hindle
- Departments of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA.
| | | |
Collapse
|
22
|
Longest PW, Hindle M. Condensational growth of combination drug-excipient submicrometer particles for targeted high efficiency pulmonary delivery: comparison of CFD predictions with experimental results. Pharm Res 2011; 29:707-21. [PMID: 21948458 DOI: 10.1007/s11095-011-0596-1] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2011] [Accepted: 09/14/2011] [Indexed: 11/27/2022]
Abstract
PURPOSE The objective of this study was to investigate the hygroscopic growth of combination drug and excipient submicrometer aerosols for respiratory drug delivery using in vitro experiments and a newly developed computational fluid dynamics (CFD) model. METHODS Submicrometer combination drug and excipient particles were generated experimentally using both the capillary aerosol generator and the Respimat inhaler. Aerosol hygroscopic growth was evaluated in vitro and with CFD in a coiled tube geometry designed to provide residence times and thermodynamic conditions consistent with the airways. RESULTS The in vitro results and CFD predictions both indicated that the initially submicrometer particles increased in mean size to a range of 1.6-2.5 μm for the 50:50 combination of a non-hygroscopic drug (budesonide) and different hygroscopic excipients. CFD results matched the in vitro predictions to within 10% and highlighted gradual and steady size increase of the droplets, which will be effective for minimizing extrathoracic deposition and producing deposition deep within the respiratory tract. CONCLUSIONS Enhanced excipient growth (EEG) appears to provide an effective technique to increase pharmaceutical aerosol size, and the developed CFD model will provide a powerful design tool for optimizing this technique to produce high efficiency pulmonary delivery.
Collapse
|
23
|
Longest PW, Tian G, Hindle M. Improving the lung delivery of nasally administered aerosols during noninvasive ventilation-an application of enhanced condensational growth (ECG). J Aerosol Med Pulm Drug Deliv 2011; 24:103-18. [PMID: 21410327 PMCID: PMC3123840 DOI: 10.1089/jamp.2010.0849] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2010] [Accepted: 10/25/2010] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Aerosol drug delivery during noninvasive ventilation (NIV) is known to be inefficient due to high depositional losses. To improve drug delivery efficiency, the concept of enhanced condensational growth (ECG) was recently proposed in which a submicrometer or nanoaerosol reduces extrathoracic deposition and subsequent droplet size increase promotes lung retention. The objective of this study was to provide proof-of-concept that the ECG approach could improve lung delivery of nasally administered aerosols under conditions consistent with NIV. METHODS Aerosol deposition and size increase were evaluated in an adult nose-mouth-throat (NMT) replica geometry using both in vitro experiments and CFD simulations. For the ECG delivery approach, separate streams of a submicrometer aerosol and warm (39°C) saturated air were generated and delivered to the right and left nostril inlets, respectively. A control case was also considered in which an aerosol with a mass median aerodynamic diameter (MMAD) of 4.67 μm was delivered to the model. RESULTS In vitro experiments showed that the ECG approach significantly reduced the drug deposition fraction in the NMT geometry compared with the control case [14.8 (1.83)%-ECG vs. 72.6 (3.7)%-control]. Aerosol size increased from an initial MMAD of 900 nm to a size of approximately 2 μm at the exit of the NMT geometry. Results of the CFD model were generally in good agreement with the experimental findings. Based on CFD predictions, increasing the delivery temperature of the aerosol stream from 21 to 35°C under ECG conditions further reduced the total NMT drug deposition to 5% and maintained aerosol growth by ECG to approximately 2 μm. CONCLUSIONS Application of the ECG approach may significantly improve the delivery of pharmaceutical aerosols during NIV and may open the door for using the nasal route to routinely deliver pulmonary medications.
Collapse
Affiliation(s)
- P Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, 23284-3015, USA.
| | | | | |
Collapse
|
24
|
Tian G, Longest PW, Su G, Hindle M. Characterization of respiratory drug delivery with enhanced condensational growth using an individual path model of the entire tracheobronchial airways. Ann Biomed Eng 2011; 39:1136-53. [PMID: 21152983 PMCID: PMC3042232 DOI: 10.1007/s10439-010-0223-z] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2010] [Accepted: 11/23/2010] [Indexed: 01/08/2023]
Abstract
The objective of this study was to evaluate the delivery of inhaled pharmaceutical aerosols using an enhanced condensational growth (ECG) approach in an airway model extending from the oral cavity to the end of the tracheobronchial (TB) region. The geometry consisted of an elliptical mouth-throat (MT) model, the upper TB airways extending to bifurcation B3, and a subsequent individual path model entering the right lower lobe of the lung. Submicrometer monodisperse aerosols with diameters of 560 and 900 nm were delivered to the mouth inlet under control (25 °C with subsaturated air) or ECG (39 or 42 °C with saturated air) conditions. Flow fields and droplet characteristics were simulated using a computational fluid dynamics model that was previously demonstrated to accurately predict aerosol size growth and deposition. Results indicated that both the control and ECG delivery cases produced very little deposition in the MT and upper TB model (approximately 1%). Under ECG delivery conditions, large size increases of the aerosol droplets were observed resulting in mass median aerodynamic diameters of 2.4-3.3 μm exiting B5. This increase in aerosol size produced an order of magnitude increase in aerosol deposition within the TB airways compared with the controls, with TB deposition efficiencies of approximately 32-46% for ECG conditions. Estimates of downstream pulmonary deposition indicted near full lung retention of the aerosol during ECG delivery. Furthermore, targeting the region of TB deposition by controlling the inlet temperature conditions and initial aerosol size also appeared possible.
Collapse
Affiliation(s)
- Geng Tian
- Department of Mechanical Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, USA
| | - Philip Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, USA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| | - Guoguang Su
- Department of Mechanical Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| |
Collapse
|
25
|
Longest PW, Hindle M. Numerical Model to Characterize the Size Increase of Combination Drug and Hygroscopic Excipient Nanoparticle Aerosols. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2011; 45:884-899. [PMID: 21804683 PMCID: PMC3143486 DOI: 10.1080/02786826.2011.566592] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Enhanced excipient growth is a newly proposed respiratory delivery strategy in which submicrometer or nanometer particles composed of a drug and hygroscopic excipient are delivered to the airways in order to minimize extrathoracic depositional losses and maximize lung retention. The objective of this study was to develop a validated mathematical model of aerosol size increase for hygroscopic excipients and combination excipient-drug particles and to apply this model to characterize growth under typical respiratory conditions. Compared with in vitro experiments, the droplet growth model accurately predicted the size increase of single component and combination drug and excipient particles. For typical respiratory drug delivery conditions, the model showed that droplet size increase could be effectively correlated with the product of a newly defined hygroscopic parameter and initial volume fractions of the drug and excipient in the particle. A series of growth correlations was then developed that successively included the effects of initial drug and excipient mass loadings, initial aerosol size, and aerosol number concentration. Considering EEG delivery, large diameter growth ratios (2.1-4.6) were observed for a range of hygroscopic excipients combined with both hygroscopic and non-hygroscopic drugs. These diameter growth ratios were achieved at excipient mass loadings of 50% and below and at realistic aerosol number concentrations. The developed correlations were then used for specifying the appropriate initial mass loadings of engineered insulin nanoparticles in order to achieve a predetermined size increase while maximizing drug payload and minimizing the amount of hygroscopic excipient.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, VA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
- Corresponding author: Dr. P. Worth Longest, PhD, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, Phone: (804)-827-7023, Fax: (804)-827-7030,
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
26
|
Longest PW, Hindle M. CFD simulations of enhanced condensational growth (ECG) applied to respiratory drug delivery with comparisons to in vitro data. JOURNAL OF AEROSOL SCIENCE 2010; 41:805-820. [PMID: 20835406 PMCID: PMC2935189 DOI: 10.1016/j.jaerosci.2010.04.006] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Enhanced condensational growth (ECG) is a newly proposed concept for respiratory drug delivery in which a submicrometer aerosol is inhaled in combination with saturated or supersaturated water vapor. The initially small aerosol size provides for very low extrathoracic deposition, whereas condensation onto droplets in vivo results in size increase and improved lung retention. The objective of this study was to develop and evaluate a CFD model of ECG in a simple tubular geometry with direct comparisons to in vitro results. The length (29 cm) and diameter (2 cm) of the tubular geometry were representative of respiratory airways of an adult from the mouth to the first tracheobronchial bifurcation. At the model inlet, separate streams of humidified air (25, 30, and 39 °C) and submicrometer aerosol droplets with mass median aerodynamic diameters (MMADs) of 150, 560, and 900 nm were combined. The effects of condensation and droplet growth on water vapor concentrations and temperatures in the continuous phase (i.e., two-way coupling) were also considered. For an inlet saturated air temperature of 39 °C, the two-way coupled numerical (and in vitro) final aerosol MMADs for initial sizes of 150, 560, and 900 nm were 1.75 μm (vs. 1.23 μm), 2.58 μm (vs. 2.66 μm), and 2.65 μm (vs. 2.63 μm), respectively. By including the effects of two-way coupling in the model, agreements with the in vitro results were significantly improved compared with a one-way coupled assumption. Results indicated that both mass and thermal two-way coupling effects were important in the ECG process. Considering the initial aerosol sizes of 560 and 900 nm, the final sizes were most influenced by inlet saturated air temperature and aerosol number concentration and were not largely influenced by initial size. Considering the growth of submicrometer aerosols to above 2 μm at realistic number concentrations, ECG may be an effective respiratory drug delivery approach for minimizing mouth-throat deposition and maximizing aerosol retention in a safe and simple manner. However, future studies are needed to explore effects of in vivo boundary conditions, more realistic respiratory geometries, and transient breathing.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, USA
- Department of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA 23298-0533, USA
- Corresponding author at: Department of Mechanical Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA 23284-3015, USA. Tel./fax: +1 804 827 7023. (P. Worth Longest), (M. Hindle)
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA 23298-0533, USA
| |
Collapse
|
27
|
Hindle M, Longest PW. Evaluation of enhanced condensational growth (ECG) for controlled respiratory drug delivery in a mouth-throat and upper tracheobronchial model. Pharm Res 2010; 27:1800-11. [PMID: 20454837 DOI: 10.1007/s11095-010-0165-z] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2010] [Accepted: 04/21/2010] [Indexed: 01/31/2023]
Abstract
PURPOSE The objective of this study is to evaluate the effects of enhanced condensational growth (ECG), as a novel inhalation drug delivery method, on nano-aerosol deposition in a mouth-throat (MT) and upper tracheobronchial (TB) model using in vitro experiments and computational fluid dynamics (CFD) simulations. METHODS Separate streams of nebulized nano-aerosols and saturated humidified air (39 degrees C-ECG; 25 degrees C-control) were combined as they were introduced into a realistic MT-TB geometry. Aerosol deposition was determined in the MT, generations G0-G2 (trachea-lobar bronchi) and G3-G5 and compared to CFD simulations. RESULTS Using ECG conditions, deposition of 560 and 900 nm aerosols was low in the MT region of the MT-TB model. Aerosol drug deposition in the G0-G2 and G3-G5 regions increased due to enhanced condensational growth compared to control. CFD-predicted depositions were generally in good agreement with the experimental values. CONCLUSIONS The ECG platform appears to offer an effective method of delivering nano-aerosols through the extrathoracic region, with minimal deposition, to the tracheobronchial airways and beyond. Aerosol deposition is then facilitated as enhanced condensational growth increases particle size. Future studies will investigate the effects of physio-chemical drug properties and realistic inhalation profiles on ECG growth characteristics.
Collapse
Affiliation(s)
- Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, 410 N. 12th St., P.O. Box 980533, Richmond, Virginia 23298-0533, USA.
| | | |
Collapse
|