Torii S, Hashimoto T, Do AT, Furumai H, Katayama H. Repeated pressurization as a potential cause of deterioration in virus removal by aged reverse osmosis membrane used in households.
THE SCIENCE OF THE TOTAL ENVIRONMENT 2019;
695:133814. [PMID:
31421339 DOI:
10.1016/j.scitotenv.2019.133814]
[Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 08/04/2019] [Accepted: 08/06/2019] [Indexed: 06/10/2023]
Abstract
Reverse osmosis (RO) membrane is widely used for household water treatment in areas with limited access to safe drinking water; however, some studies documented deterioration in the quality of RO permeate. Repeated pressurization from intermittent operation in households is suspected to have an adverse effect on RO. This study aimed to evaluate virus removal by RO used in actual households as well as the water quality of permeate, and to elucidate the main cause of RO deterioration. We conducted a survey in households in Hanoi, Vietnam, to collect 27 membranes along with their usage history, where virus removal was investigated in laboratory. Of the used RO membranes, 22% did not show the protective level, >3 log10 (99.9%) virus removal, recommended by World Health Organization. The differences in virus removal among Aichi virus, MS2 and φX-174 were <0.5 log10. All membranes with estimated pressurization times of <4000 showed >3 log10 virus removal, while 17% of membranes used for <3years, the manufacturers' warranty period, did not achieve the criterion. Therefore, virus removal performance may not be assured even if the users replace the membrane following the warranty period. Furthermore, more pressurized membranes exhibited significantly lower virus removal than less pressurized ones, suggesting a major role of repeated pressurization in the deterioration of RO. Coliforms were detected from 44% of the permeate of the point-of-use devices applying RO (RO-POU), raising concerns on the extrinsic contamination and regrowth of bacteria. Consequently, RO in households may deteriorate more rapidly than the manufactures' expectation due to repeated pressurization. RO in households should be replaced based on not only membrane age but also total pressurized times (i.e., 4000 times) to keep the protective level of virus removal. The deteriorated bacterial quality in RO permeate suggested the need for installing post-treatment, such as UV irradiation.
Collapse