1
|
Ross CL, Syed I, Smith TL, Harrison BS. The regenerative effects of electromagnetic field on spinal cord injury. Electromagn Biol Med 2016; 36:74-87. [DOI: 10.3109/15368378.2016.1160408] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
2
|
Effect of the external electric field on selected tripeptides. Amino Acids 2015; 47:1399-408. [DOI: 10.1007/s00726-015-1971-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Accepted: 03/23/2015] [Indexed: 10/23/2022]
|
3
|
|
4
|
Berg H, Zhang L. Electrostimulation in Cell Biology by Low-Frequency Electromagnetic Fields. ACTA ACUST UNITED AC 2009. [DOI: 10.3109/15368379309012869] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
5
|
Sisken BF, Fowler I, Mayaud C, Ryaby JP, Ryaby J, Pilla AA. Pulsed Electromagnetic Fields and Normal Chick Development. ACTA ACUST UNITED AC 2009. [DOI: 10.3109/15368378609027715] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
6
|
Sisken BF, Midkiff P, Tweheus A, Markov M. Influence of static magnetic fields on nerve regeneration in vitro. ACTA ACUST UNITED AC 2007. [DOI: 10.1007/s10669-007-9117-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
7
|
Bervar M. Effect of weak, interrupted sinusoidal low frequency magnetic field on neural regeneration in rats: Functional evaluation. Bioelectromagnetics 2005; 26:351-6. [PMID: 15887258 DOI: 10.1002/bem.20108] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A study of the effect of weak, interrupted sinusoidal low frequency magnetic field (ISMF) stimulation on regeneration of the rat sciatic nerve was carried out. In the experiment, 60 Wistar rats were used: 24 rats underwent unilateral sciatic nerve transection injury and immediate surgical nerve repair, 24 rats underwent unilateral sciatic nerve crush injury, and the remaining 12 rats underwent a sham surgery. Half of the animals (n = 12) with either sciatic nerve lesion were randomly chosen and exposed between a pair of Helmholtz coils for 3 weeks post-injury, 4 h/day, to an interrupted (active period to pause ratio = 1.4 s/0.8 s) sinusoidal 50 Hz magnetic field of 0.5 mT. The other half of the animals (n = 12) and six rats with sham surgery were used for two separate controls. Functional recovery was followed for 6 weeks for the crush injuries and 7(1/2) months for the transection injuries by video assisted footprint analysis in static conditions and quantified using a recently revised static sciatic index (SSI) formula. We ascertained that the magnetic field influence was weak, but certainly detectable in both injury models. The accuracy of ISMF influence detection, determined by the one-way repeated measures ANOVA test, was better for the crush injury model: F(1, 198) = 9.0144, P = .003, than for the transection injury model: F(1, 198) = 6.4826, P = .012. The Student-Newman-Keuls range test for each response day yielded significant differences (P < .05) between the exposed and control groups early in the beginning of functional recovery and later on from the points adjacent to the beginning of the plateau, or 95% of functional recovery, and the end of observation. These differences probably reflect the ISMF systemic effect on the neuron cell bodies and increased and more efficient reinnervation of the periphery.
Collapse
Affiliation(s)
- Marijan Bervar
- Department of Plastic and Reconstructive Surgery, Maribor General Hospital, Maribor, Slovenia.
| |
Collapse
|
8
|
Crowe MJ, Sun ZP, Battocletti JH, Macias MY, Pintar FA, Maiman DJ. Exposure to pulsed magnetic fields enhances motor recovery in cats after spinal cord injury. Spine (Phila Pa 1976) 2003; 28:2660-6. [PMID: 14673366 DOI: 10.1097/01.brs.0000099385.46102.0d] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Animal model study of eight healthy commercial cats was conducted. OBJECTIVE To determine whether pulsed electromagnetic field (PMF) stimulation results in improvement of function after contusive spinal cord injury in cats. SUMMARY OF BACKGROUND DATA PMF stimulation has been shown to enhance nerve growth, regeneration, and functional recovery of peripheral nerves. Little research has been performed examining the effects of PMF stimulation on the central nervous system and no studies of PMF effects on in vivo spinal cord injury (SCI) models have been reported. MATERIALS AND METHODS PMF stimulation was noninvasively applied for up to 12 weeks to the midthoracic spine of cats with acute contusive spinal cord injury. The injury was produced using a weight-drop apparatus. Motor functions were evaluated with the modified Tarlov assessment scale. Morphologic analyses of the injury sites and somatosensory-evoked potential measurements were conducted to compare results between PMF-stimulated and control groups. RESULTS There was a significant difference in locomotor recovery between the PMF-stimulated and control groups. Although not statistically significant, PMF-stimulated spinal cords demonstrated greater sparing of peripheral white matter and smaller lesion volumes compared to controls. Somatosensory-evoked potential measurements indicated that the PMF-stimulated group had better recovery of preinjury waveforms than the control group; however, this observation also was not statistically significant because of the small sample size. CONCLUSIONS This preliminary study indicates that pulsed magnetic fields may have beneficial effects on motor function recovery and lesion volume size after acute spinal cord injury.
Collapse
Affiliation(s)
- Maria J Crowe
- Neuroscience Research Laboratories, The Clement J. Zablocki VA Medical Center, Milwaukee, WI 53295, USA.
| | | | | | | | | | | |
Collapse
|
9
|
Oishi M, Onesti ST. Electrical bone graft stimulation for spinal fusion: a review. Neurosurgery 2000; 47:1041-55; discussion 1055-6. [PMID: 11063097 DOI: 10.1097/00006123-200011000-00005] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Although electrical stimulation to aid bone fusion is well established in the treatment of long-bone fractures, its use as an aid in spinal fusion is not as well documented. This article presents the history and scientific basis of electrical stimulation to aid bone fusion and extensively reviews the clinical literature. It is intended to provide an objective review of the indications and limitations of electrical stimulation to enhance spinal fusion and to serve as a reference source for further study.
Collapse
Affiliation(s)
- M Oishi
- Department of Neurological Surgery, Montefiore Medical Center, Bronx, New York 10467, USA
| | | |
Collapse
|
10
|
Greenebaum B, Sutton CH, Vadula MS, Battocletti JH, Swiontek T, DeKeyser J, Sisken BF. Effects of pulsed magnetic fields on neurite outgrowth from chick embryo dorsal root ganglia. Bioelectromagnetics 1996; 17:293-302. [PMID: 8891188 DOI: 10.1002/(sici)1521-186x(1996)17:4<293::aid-bem5>3.0.co;2-z] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
We have previously shown that neurite outgrowth from 6-day chick embryo dorsal root ganglia (DRG) in vitro was stimulated when nerve growth factor (NGF) and pulsed magnetic fields (PMF) are used in combination. 392 DRGs were studied in a field excited by a commercial PMF generator. We have now analyzed an additional 416 DRGs exposed to very similar PMF's produced by an arbitrary wavefrom generator and power amplifier. We reproduced our previous findings that combination of NGF and bursts of asymmetric, 220 microsecond-wide, 4.0 mT-peak pulses induced significantly (p < 0.05) greater outgrowth than NGF alone, that fields without NGF do not significantly alter outgrowth, and that, unlike NGF alone, 4.0 mT fields and NGF can induce asymmetric outgrowth. The asymmetry does not seem to have a preferred orientation with respect to the induced electric field. Analysis of the data for the entire 808 DRGs confirms these findings. Importantly, we find similar results for pulse bursts repeated at 15 or 25 Hz.
Collapse
Affiliation(s)
- B Greenebaum
- Biomedical Research Institute, University of Wisconsin-Parkside, Kenosha, WI, USA
| | | | | | | | | | | | | |
Collapse
|
11
|
Sisken BF, Jacob JM, Walker JL. Acute treatment with pulsed electromagnetic fields and its effect on fast axonal transport in normal and regenerating nerve. J Neurosci Res 1995; 42:692-9. [PMID: 8600302 DOI: 10.1002/jnr.490420512] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The mechanism whereby low-frequency electromagnetic fields accelerate axonal regrowth and regeneration of peripheral nerve after crush lesion is not known. One candidate is an alteration in axonal transport. In this study we exposed unoperated rats for 15 min/day, and rats that had undergone a crush lesion of the sciatic nerve, for 1 hr/day for 2 days, to 2-Hz pulsed electromagnetic fields. To label fast transported proteins, [3H]-proline was microinjected into the spinal cord, and the sciatic nerves were removed 2, 3.5, and 5 hr later. The rates of fast axonal transport were obtained for animals in all groups by counting sequential 2-mm segments of nerves. The following transport rates were found: in unoperated normal sciatic nerve not exposed to PEMF, 373 +/- 14 mm/day; in unoperated normal nerve exposed to PEMF, 383 +/- 14 mm/day; in sham crush nerves not exposed to PEMF, 379 +/- 19 mm/day; in sham crush nerve exposed to PEMF, 385 +/- 17 mm/day; in crushed nerves not exposed to PEMF, 393 +/- 16 mm/day. and in crushed nerves exposed to PEMF, 392 +/- 15 mm/day. The results of these experiments indicate that 1) a crush injury to the sciatic nerve does not alter the rate of fast axonal transport, and 2) low-frequency pulsed electromagnetic fields do not alter fast axonal transport rates in operated (crush) or unoperated sciatic nerves.
Collapse
Affiliation(s)
- B F Sisken
- Department of Anatomy and Neurobiology, University of Kentucky, Lexington 40506, USA
| | | | | |
Collapse
|
12
|
Khan T, Myklebust J, Swiontek T, Sayers S, Dauzvardis M. Electrical field distribution within the injured cat spinal cord: injury potentials and field distribution. J Neurotrauma 1994; 11:699-710. [PMID: 7723069 DOI: 10.1089/neu.1994.11.699] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
This study investigated the spontaneous injury potentials measured after contusion or transection injury to the cat spinal cord. In addition, the distribution of electrical field potentials on the surface and within the spinal cord were measured following applied electrical fields after transection and contusion injuries. After transection of the spinal cord, the injury potentials were -19.8 +/- 2.6 mV; after contusion of the spinal cord, the injury potentials were -9.5 +/- 2.2 mV. These potentials returned to control values within 2.5-4h after injury. The electrical field distribution measured on the dorsal surface, as well as within the spinal cord, after the application of a 10 microA current, showed little difference between contusion and transection injuries. Scalar potential fields were measured using two configurations of stimulating electrodes: dorsal to dorsal (D-D), in which both electrodes were placed epidurally on the dorsal surface of the spinal cord, and ventral to dorsal (V-D), in which one electrode was placed dorsally and one ventrally. As reported in normal uninjured cats, the total current in the midsagittal plane for the D-D configuration was largely confined to the dorsal portion of the spinal cord; with the V-D configuration, the current distribution was uniform throughout the spinal cord. In the injured spinal cord, the equipotential lines midway between the stimulating electrodes have a wider separation than in the uninjured spinal cord. Because the magnitude of the electrical field E is equal to the current density J multiplied by the resistivity r, this suggests that either the current density is reduced or that the resistivity is reduced.
Collapse
Affiliation(s)
- T Khan
- Rehabilitation Research and Development Center, Hines Veterans Administration Hospital, Illinois, USA
| | | | | | | | | |
Collapse
|
13
|
|
14
|
Berg H. Electrostimulation of cell metabolism by low frequency electric and electromagnetic fields. ACTA ACUST UNITED AC 1993. [DOI: 10.1016/0302-4598(93)86102-7] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
15
|
Sisken BF, Walker J, Orgel M. Prospects on clinical applications of electrical stimulation for nerve regeneration. J Cell Biochem 1993; 51:404-9. [PMID: 8496243 DOI: 10.1002/jcb.2400510404] [Citation(s) in RCA: 100] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Regenerative capability is limited in higher vertebrates but present in organ systems such as skin, liver, bone, and to some extent, the nervous system. Peripheral nerves in particular have a relatively high potential for regeneration following injury. However, delay in regrowth or growth, blockage, or misdirection at the injury site, and growth to inappropriate end organs may compromise successful regeneration, leading to poor clinical results. Recent studies indicate that low-intensity electrical stimulation is equivalent to various growth factors, offering avenues to improve these outcomes. We present a review of studies using electric and electromagnetic fields that provide evidence for the enhancement of regeneration following nerve injury. Electric and electromagnetic fields (EMFs) have been used to heal fracture non-unions. This technology emerged as a consequence of basic studies [Yasuda, 1953; Fukada and Yasuda, 1957] demonstrating the piezoelectric properties of (dry) bone. The principle for using electrical stimulation for bone healing originated from the work of Bassett and Becker [1962], who described asymmetric voltage waveforms from mechanically deformed live bone. These changes were presumed to occur in bone during normal physical activity as a result of mechanical forces, and it was postulated that these forces were linked to modifications in bone structure. Endogenous currents present in normal tissue and those that occur after injury were proposed to modify bone structure [Bassett, 1989]. These investigators proposed that tissue integrity and function could be restored by applying electrical and/or mechanical energy to the area of injury. They successfully applied electrical currents to nonhealing fractures (using surgically implanted electrodes or pulsed currents using surface electrodes) to aid endogenous currents in the healing process.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- B F Sisken
- Center for Biomedical Engineering, University of Kentucky, Lexington 40506
| | | | | |
Collapse
|
16
|
Kanje M, Rusovan A, Sisken B, Lundborg G. Pretreatment of rats with pulsed electromagnetic fields enhances regeneration of the sciatic nerve. Bioelectromagnetics 1993; 14:353-9. [PMID: 8216387 DOI: 10.1002/bem.2250140407] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Regeneration of the sciatic nerve was studied in rats pretreated in a pulsed electromagnetic field (PEMF). The rats were exposed between a pair of Helmholtz coils at a pulse repetition rate of 2 pps at a field density of 60 or 300 microT. The PEMF treatment was then discontinued. After an interval of recovery, regeneration of the sciatic nerve was initiated by a crush lesion. Regeneration of sensory fibers was measured by the "pinch test" after an additional 3-6 days. A variety of PEMF pretreatments including 4 h/day for 1-4 days or exposure for 15 min/day during 2 days resulted in an increased regeneration distance, measured 3 days after the crush lesion. This effect could be demonstrated even after a 14-day recovery period. In contrast, pretreatment for 4 h/day for 2 days at 60 microT did not affect the regeneration distance. The results showed that PEMF pretreatment conditioned the rat sciatic nerve in a manner similar to that which occurs after a crush lesion, which indicates that PEMF affects the neuronal cell body. However, the mechanism of this effect remains obscure.
Collapse
Affiliation(s)
- M Kanje
- Department of Animal Physiology, University of Lund, Sweden
| | | | | | | |
Collapse
|
17
|
Bassen H, Litovitz T, Penafiel M, Meister R. ELF in vitro exposure systems for inducing uniform electric and magnetic fields in cell culture media. Bioelectromagnetics 1992; 13:183-98. [PMID: 1590818 DOI: 10.1002/bem.2250130303] [Citation(s) in RCA: 56] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Many in vitro experiments on the biological effects of extremely low frequency (ELF) electromagnetic fields utilize a uniform external magnetic flux density (B) to expose biological materials. A significant number of researchers do not measure or estimate the resulting electric field strength (E) or current density (J) in the sample medium. The magnitude and spatial distribution of the induced E field are highly dependent on the sample geometry and its relative orientation with respect to the magnetic field. We have studied the E fields induced in several of the most frequently used laboratory culture dishes and flasks under various exposure conditions. Measurements and calculations of the E field distributions in the aqueous sample volume in the containers were performed, and a set of simple, quantitative tables was developed. These tables allow a biological researcher to determine, in a straightforward fashion, the magnitudes and distributions of the electric fields that are induced in the aqueous sample when it is subjected to a uniform, sinusoidal magnetic field of known strength and frequency. In addition, we present a novel exposure technique based on a standard organ culture dish containing two circular, concentric annular rings. Exposure of the organ culture dish to a uniform magnetic field induces different average electric fields in the liquid medium in the inner and outer rings. Results of experiments with this system, which were reported in a separate paper, have shown the dominant role of the magnetically induced E field in producing specific biological effects on cells, in vitro. These results emphasize the need to report data about the induced E field in ELF in-vitro studies, involving magnetic field exposures. Our data tables on E and J in standard containers provide simple means to enable determination of these parameters.
Collapse
Affiliation(s)
- H Bassen
- Walter Reed Army Institute of Research, Department of Microwave Research, Washington, DC
| | | | | | | |
Collapse
|
18
|
Astumian D, Berg H. Direct electric field effects and sequential processes in biosystems. J Electroanal Chem (Lausanne) 1991. [DOI: 10.1016/0022-0728(91)85660-h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
19
|
Rusovan A, Kanje M. Stimulation of regeneration of the rat sciatic nerve by 50 Hz sinusoidal magnetic fields. Exp Neurol 1991; 112:312-6. [PMID: 2029930 DOI: 10.1016/0014-4886(91)90132-v] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The effect of sinusoidal magnetic field stimulation on regeneration of the rat sciatic nerve was studied. Rats were exposed, after crush lesioning of the nerve, between a pair of Helmholtz coils to a 50 Hz magnetic field of 0.2 mT or 0.4 mT, respectively. Regeneration of the sciatic nerve was measured by the "pinch test," or by immunocytochemical staining for neurofilaments 1 to 6 days after the crush lesion. Intermittent stimulation (4 h/day) at 0.2 mT did not affect regeneration, while continuous stimulation with the same field enhanced regeneration distances measured at Days 1, 2, and 3. Intermittent stimulation with 0.4 mT increased regeneration distances in 3-day regenerated nerves. In the rats exposed continuously to 0.4 mT regeneration was higher in all groups (1, 2, 3, 4, and 6 days). This field enhanced the regeneration velocity by 21%. Pretreatment for 7 days with continuous stimulation either at 0.2 mT or at 0.4 mT did not affect regeneration of the sciatic nerve after a crush lesion.
Collapse
Affiliation(s)
- A Rusovan
- Department of Zoophysiology, University of Lund, Sweden
| | | |
Collapse
|
20
|
Astumian D, Berg H. Direct electric field effects and sequential processes in biosystems. ACTA ACUST UNITED AC 1991. [DOI: 10.1016/0302-4598(91)80010-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
21
|
|
22
|
Beers GJ. Biological effects of weak electromagnetic fields from 0 Hz to 200 MHz: a survey of the literature with special emphasis on possible magnetic resonance effects. Magn Reson Imaging 1989; 7:309-31. [PMID: 2668675 DOI: 10.1016/0730-725x(89)90556-0] [Citation(s) in RCA: 71] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The literature on biological effects of weak electromagnetic fields of a frequency of 200 MHz or less is surveyed. The topic has been extraordinarily controversial, in part because of disputed assertions about a role for electromagnetic fields in carcinogenesis or production of abnormalities in growth and development. There is fairly widespread acceptance of certain beneficial effects, particularly the stimulation of healing. An increasing number of reports point to interactions between static magnetic fields and time-varying fields in the production of some effects. Safety implications are noted along with the hypothetical possibility of production of experimental artifacts by electromagnetic fields in MRS research.
Collapse
Affiliation(s)
- G J Beers
- Department of Radiology, Boston University Medical Center, MA 02118
| |
Collapse
|
23
|
Sisken BF, Kanje M, Lundborg G, Herbst E, Kurtz W. Stimulation of rat sciatic nerve regeneration with pulsed electromagnetic fields. Brain Res 1989; 485:309-16. [PMID: 2497929 DOI: 10.1016/0006-8993(89)90575-1] [Citation(s) in RCA: 132] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The effects of pulsed electromagnetic fields (PEMF) on rat sciatic nerve regeneration after a crush lesion were determined. The rats were placed between a pair of Helmholtz coils and exposed to PEMF of frequency 2 Hz and magnetic flux density of 0.3 mT. A 4 h/day treatment for 3-6 days increased the rate of nerve regeneration by 22%. This stimulatory effect was independent of the orientation of the coils. Exposure times of 1 h/day-10 h/day were equally effective in stimulating nerve regeneration. Rats exposed to PEMF for 4 h/day for 7 days before crush, followed by 3 days after crush without PEMF, also showed significantly increased regeneration. This pre-exposure 'conditioning' effect suggests that PEMF influences regeneration indirectly.
Collapse
Affiliation(s)
- B F Sisken
- Center for Biomedical Engineering, University of Kentucky, Lexington 40506
| | | | | | | | | |
Collapse
|
24
|
Effects of electric fields and currents on living cells and their potential use in biotechnology: a survey. J Electroanal Chem (Lausanne) 1988. [DOI: 10.1016/0022-0728(80)80340-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
25
|
|
26
|
Teissié J. Effects of electric fields and currents on living cells and their potential use in biotechnology: A survey. ACTA ACUST UNITED AC 1988. [DOI: 10.1016/s0302-4598(98)80011-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
27
|
|
28
|
Elliott JP, Smith RL, Block CA. Time-varying magnetic fields: effects of orientation on chondrocyte proliferation. J Orthop Res 1988; 6:259-64. [PMID: 3343631 DOI: 10.1002/jor.1100060213] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The purpose of this study was to determine the effect of orientation of pulsed electromagnetic fields (PEMFs) on cellular proliferation and extracellular matrix synthesis. Bovine articular chondrocytes were cultured in PEMFs (repetitive pulse at 72 Hz) generated using Helmholtz coils oriented either parallel (horizontal) or perpendicular (vertical) to the plane of cell adhesion. Dissipation of signal energy in the form of heat increased the temperature of the PEMF coils by 2 degrees C and the tissue culture medium by 1 degree C. Therefore, control coils, which emitted no PEMFs, were heated to the temperature of PEMF coils by circulating water. Chondrocytes were cultured in 16-mm-well culture plates, and the data for individual wells were pooled as triplicates. Although not observed by microscopic examination of individual wells, positionally dependent electric field effects may be minimized by this approach. PEMFs generated by coils oriented vertically significantly decreased chondrocyte proliferation. The effect was dependent on the concentration of serum in the culture media. At 3% serum concentration, the total cell number attained after 10 days of culture was reduced by 50% in stimulated cultures when compared with controls. At 5% serum concentration, there was no effect. PEMFs applied by coils oriented horizontally did not alter proliferation of articular chondrocytes. PEMFs had no effect on synthesis of extracellular matrix by chondrocytes plated at high density, irrespective of orientation.
Collapse
Affiliation(s)
- J P Elliott
- Orthopaedic Research Laboratory, Stanford University School of Medicine, California
| | | | | |
Collapse
|
29
|
|
30
|
De Loof A. The electrical dimension of cells: the cell as a miniature electrophoresis chamber. INTERNATIONAL REVIEW OF CYTOLOGY 1986; 104:251-352. [PMID: 3531065 DOI: 10.1016/s0074-7696(08)61927-0] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
31
|
Mazzoleni AP, Sisken BF, Kahler RL. Conductivity values of tissue culture medium from 20 degrees C to 40 degrees C. Bioelectromagnetics 1986; 7:95-9. [PMID: 3730006 DOI: 10.1002/bem.2250070111] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Few studies are available that relate conductivity and temperature in solutions commonly used in tissue culture media. The purpose of this paper is to provide equations relating conductivity and temperature (in the range 20 degrees C-40 degrees C) for five solutions: 0.9% saline, MEM (Minimum Essential Media), horse serum, MEM with 1% horse serum, and MEM with 10% horse serum.
Collapse
|
32
|
McLeod BR, Liboff AR. Dynamic characteristics of membrane ions in multifield configurations of low-frequency electromagnetic radiation. Bioelectromagnetics 1986; 7:177-89. [PMID: 3741492 DOI: 10.1002/bem.2250070208] [Citation(s) in RCA: 86] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
We seek to extend the recent suggestion that classical cyclotron resonance of biologically important ions is implicated in weak electromagnetic field-cell interactions. The motion of charged particles in a constant magnetic field and periodic electric field is examined under the simplifying assumption of no damping. Each of the nine terms of the relative dielectric tensor is found to have a dependence on functions that include the factor (omega 2 - omega 2B)-1, where omega B is the gyrofrequency. We also find a plasmalike decomposition of the electric field into oppositely rotating components that could conceivably act to drive oppositely charged ions in the same direction through helical membrane channels. For weak low-frequency magnetic fields, an additional feature arises, namely, periodic reinforcement of the resonance condition with intervals of the order of tens of msec for biological ions such as Li+, Na+, and K+.
Collapse
|
33
|
|