1
|
Liu S, Hall DJ, Dommann-Scherrer C, Pourzal R, Wahl P. Fourier-transform infrared spectroscopy imaging is a useful adjunct to routine histopathology to identify failure of polyethylene inlays in revision total hip arthroplasty. APMIS 2024; 132:553-563. [PMID: 38741279 DOI: 10.1111/apm.13421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 04/26/2024] [Indexed: 05/16/2024]
Abstract
The use of highly crosslinked ultra-high molecular weight polyethylene (XLPE) has significantly reduced the volumetric wear of acetabular liners, thereby reducing the incidence of osteolysis. However, contemporary components tend to generate smaller wear particles, which can no longer be identified using conventional histology. This technical limitation can result in imprecise diagnosis. Here, we report on two uncemented total hip arthroplasty cases (~7 years in situ) revised for periprosthetic fracture of the femur and femoral loosening, respectively. Both liners exhibited prominent wear. The retrieved pseudocapsular tissue exhibited a strong macrophage infiltration without microscopically identifiable polyethylene particles. Yet, using Fourier-transform infrared micro-spectroscopic imaging (FTIR-I), we demonstrated the prominent intracellular accumulation of polyethylene debris in both cases. This study shows that particle induced osteolysis can still occur with XLPE liners, even under 10 years in situ. Furthermore, we demonstrate the difficulty of determining the presence of polyethylene debris within periprosthetic tissue. Considering the potentially increased bioactivity of finer particles from XLPE compared to conventional liners, an accurate detection method is required, and new histopathological hallmarks of particle induced osteolysis are needed. FTIR-I is a great tool to that end and can help the accurate determination of foreign body tissue responses.
Collapse
Affiliation(s)
- Songyun Liu
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | | | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
- Faculty of Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Nerys-Figueroa J, Parsa A, Curley A, Charif S, Domb BG, Schinsky MF. Slightly reduced early subsidence with similar outcomes and complications rate in collared stems - A systematic review of randomized clinical trials. J Orthop 2024; 50:170-176. [PMID: 38328796 PMCID: PMC10845209 DOI: 10.1016/j.jor.2024.01.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 01/05/2024] [Accepted: 01/24/2024] [Indexed: 02/09/2024] Open
Abstract
Background There is a growing trend towards using femoral stems with a medial calcar collar during total hip arthroplasty (THA). Purpose Systematically review the literature comparing a femoral collared stem and femoral collarless stem on subsidence, patient-reported outcomes (PROs), and revision rate. Study design Systematic Review, Level of Evidence 1. Methods A literature search of Pubmed and Medline was according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Randomized controlled trials that evaluated collared and collarless stems, subsidence and PROs for adult patients undergoing total hip arthroplasty (THA) were included. Additional data collection included patient demographics, stem-calcar contact, canal-fill ratio (CFR), stem orientation, surgical approach, Dorr Type, complications, and revisions. Results Five studies met inclusion criteria. 674 patients (704 hips) were included. Mean patient ages ranged 58.5-72.4 years old, and mean BMI ranged 26.6-29.8 kg/m2. Mean reported follow-up of the included clinical trials ranged 1-9.6 years. Two studies reported mean early subsidence at two weeks postoperatively, which was 0.36, 0.99 mm for collared stems and 0.52, 3.22 mm for collarless stems, proving to be statistically significant (P = 0.023), (P = 0.05). All studies demonstrated improved PROs at most recent follow-up. Revision rates ranged from 4 to 11.3 %, but these were not statistically significant. Conclusions Implantation of collared stems compared to collarless may reduce early post-operative subsidence, while no substantial effect on aseptic loosening, thigh pain, proximal femoral fracture, and revision is seen. When measuring patient-reported outcomes, the collared femoral stem was not superior to the collarless femoral stem as both resulted in similar improvement preoperatively to postoperative state.
Collapse
Affiliation(s)
| | - Ali Parsa
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
| | - Andrew Curley
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
| | - Sam Charif
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
| | - Benjamin G. Domb
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
- American Hip Institute, Chicago, IL, 60018, USA
| | - Mark F. Schinsky
- American Hip Institute Research Foundation, Chicago, IL, 60018, USA
- American Hip Institute, Chicago, IL, 60018, USA
| |
Collapse
|
3
|
Paoli E, Bergadano D, Sheng S, Pandit H. National Registry Data Analysis on a Unique Highly-Crosslinked Polyethylene for Total Hip Arthroplasty. Arthroplast Today 2023; 24:101267. [PMID: 38023652 PMCID: PMC10679760 DOI: 10.1016/j.artd.2023.101267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 09/21/2023] [Accepted: 10/14/2023] [Indexed: 12/01/2023] Open
Abstract
Background Several types of highly-crosslinked polyethylene with different manufacturing processes and mechanical properties are commercially available, including HIGHCROSS (Medacta). The aim of this registry study is to ascertain the long-term safety of the HIGHCROSS liners in total hip arthroplasty and compare the revision rates with its contemporaries using real-world data to establish their safety and generalizability when used by multiple surgeons. Methods The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) and the Swiss National Joint Registry (SIRIS) were selected for the large number of users of Medacta implants and the availability of long-term results. Three reports from SIRIS and 4 reports from AOANJRR were examined to establish the overall and Kaplan-Meier (KM) cumulative revision rate. Results According to SIRIS, the HIGHCROSS liner was the most commonly used bearing surface with Medacta stems with overall revision rates for wear/osteolysis at 9.7 years of 0.04% and 0.03%, respectively, for AMIStem and Quadra. Based on AOANJRR, the KM cumulative revision rate for any reason of Medacta stems with HIGHCROSS liners was lower than that with ceramic liners at 3 years for MasterLoc and at 10 years for Quadra. The KM cumulative revision rate for any reasons of Medacta cementless cups with HIGHCROSS liners at 12 years was lower than the comparator made of all other implants and tribological couplings (1.6% vs 2.1%). Conclusions This real-world data proves that long-term HIGHCROSS survival rates are comparable to other modern bearing surfaces.
Collapse
Affiliation(s)
- Elda Paoli
- Medacta International, Castel San Pietro, Switzerland
| | | | | | - Hemant Pandit
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| |
Collapse
|
4
|
Hong Y, Johnston L, Wang W. A Multi-factor Analysis of Revision in Total Hip Replacement Using the Collarless-Polished-Tapered Stems with Different Cups. Orthop Surg 2023. [PMID: 37385946 DOI: 10.1111/os.13778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 05/08/2023] [Accepted: 05/17/2023] [Indexed: 07/01/2023] Open
Abstract
OBJECTIVE Collarless-polished-tapered (CPT) stems have been widely used in total hip replacement (THR). Given that various types of cups are combined with CPT in clinical practice, however, what cup type performs the best for use with CPT is still unclear. This study aimed to investigate the effects of three types of commonly used cups with CPT on revision and survival life using multi-factor analysis. METHODS This study is a cohort study using the data between October 1998 to September 2021. The data of THR patients with ZCA All-poly Acetabular Cup, Continuum Acetabular System, and Trilogy Acetabular System with CPT were collected from several hospitals in the UK. The patients aged from 20 to 97 (n = 5981, 2345 male and 3636 female). Age, gender, body mass index, diagnosis, surgeon grade, cup material, cup size, surgical approach, survival life, complications, and Harris hip scores (HHS) were analyzed in relation to revision status. SPSS statistical software was used to analyze the relationship among various factors. The main statistical methods included chi-square with cross tables, analysis of variance (ANOVA) and survival analysis. RESULTS The results in relation to HHS shows that the continuum cup has the best outcome in the postoperative period of 1 and 5 years (1 year = 90.7, 5 years = 91.3; P < 0.001); the Trilogy cup was the second (1 year = 88.4, 5 years = 87.3; P < 0.001); and the ZCA cup was the third (1 year = 84.6, 5 years = 82.4; P < 0.001). However, the Trilogy cup performed the best regarding survival life on revision while the Continuum cup was the worst. CONCLUSION When the CPT stem is combined with different cups, the trilogy cup shows the best characteristics in terms of survival trends with revision ratios compared with the continuum and ZCA cups, and is therefore recommended by this study.
Collapse
Affiliation(s)
- Yu Hong
- University Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, TORT Centre, University of Dundee, Dundee, UK
| | - Linda Johnston
- University Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, TORT Centre, University of Dundee, Dundee, UK
| | - Weijie Wang
- University Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, TORT Centre, University of Dundee, Dundee, UK
| |
Collapse
|
5
|
Wahl P, Mossu-Haas C, Dommann-Scherrer C, Wei K, Eschbach L, Gehr P, Benninger E. Early failure of a highly cross-linked polyethylene inlay after total hip arthroplasty probably due to insufficient irradiation. Proc Inst Mech Eng H 2022; 236:1711-1719. [DOI: 10.1177/09544119221130673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Highly cross-linked polyethylene (XLPE) is a major advance in total hip arthroplasty (THA), as it suffers from less wear and thus is associated with lower revision rates than standard ultra-high molecular weight polyethylene. Early failures are reported rarely, and associated with specific design or manufacturing issues. We report a case requiring early revision due to adverse reaction to polyethylene particles. Investigations identified insufficient irradiation as the most probable cause of failure. Here are reported the features of a clinical case with determination of the material properties of the retrieved XLPE liner and establishment of the appropriate calibration curves as reference. Periprosthetic joint infection could be ruled out with appropriate sampling as cause for the inflammatory periarticular tumour. Histology identified a massive macrophagic reaction to micrometric polyethylene particles. No component malposition was present, nor any third-body wear. The trans-vinylene index (TVI) indicated insufficient and potentially detrimental irradiation of the polyethylene, while gel content, crystallinity, melting temperature and oxidation index remained within expected ranges. Histologically proven failure of a XLPE THA liner was identifiable despite correct implantation of the components. The cause of failure most probably was an inadequate irradiation, as indicated by determination of the TVI. This case underscores the importance of histologic workup even in aseptic revisions, and of detailed analysis of retrievals. The calibration curves provided are essential for analysis of other retrievals.
Collapse
Affiliation(s)
- Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | | | | | - Kongchang Wei
- Laboratory for Biomimetic Membranes and Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, St. Gallen, Switzerland
| | | | - Peter Gehr
- Institute of Anatomy, University of Berne, Berne, Switzerland
| | - Emanuel Benninger
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| |
Collapse
|
6
|
Medley JB. Highly cross‐linked polyethylene is the new ‘gold standard’ bearing material for total hip arthroplasty. BIOSURFACE AND BIOTRIBOLOGY 2021. [DOI: 10.1049/bsb2.12007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Affiliation(s)
- John B. Medley
- Department of Mechanical and Mechatronics Engineering University of Waterloo Waterloo Ontario Canada
| |
Collapse
|
7
|
Davis ET, Pagkalos J, Kopjar B. A higher degree of polyethylene irradiation is associated with a reduced risk of revision for aseptic loosening in total hip arthroplasties using cemented acetabular components: an analysis of 290,770 cases from the National Joint Registry of England, Wales, Northern Island and the Isle of Man. Bone Joint Res 2020; 9:563-571. [PMID: 33005395 PMCID: PMC7502255 DOI: 10.1302/2046-3758.99.bjr-2020-0135.r1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Aims To investigate the effect of polyethylene manufacturing characteristics and irradiation dose on the survival of cemented and reverse hybrid total hip arthroplasties (THAs). Methods In this registry study, data from the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man (NJR) were linked with manufacturing data supplied by manufacturers. The primary endpoint was revision of any component. Cox proportional hazard regression was a primary analytic approach adjusting for competing risk of death, patient characteristics, head composition, and stem fixation. Results A total of 290,770 primary THAs were successfully linked with manufacturing characteristics. Overall 4,708 revisions were analyzed, 1,260 of which were due to aseptic loosening. Total radiation dose was identified as a risk factor and included in the Cox model. For statistical modelling of aseptic loosening, THAs were grouped into three categories: G1 (no radiation); G2 ( > 0 to < 5 Mrad); and G3 ( ≥ 5 Mrad). G1 had the worst survivorship. The Cox regression hazard ratio for revision due to aseptic loosening for G2 was 0.7 (95% confidence interval (CI) 0.58 to 0.83), and for G3 0.4 (95% CI 0.30 to 0.53). Male sex and uncemented stem fixation were associated with higher risk of revision and ceramic heads with lower risk. Conclusion Polyethylene irradiation was associated with reduced risk of revision for aseptic loosening. Radiation doses of ≥ 5 Mrad were associated with a further reduction in risk. Cite this article: Bone Joint Res 2020;9(9):563–571.
Collapse
Affiliation(s)
- Edward T Davis
- Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, UK.,Institute of Inflammation and Ageing, University of Birmingham, Birmingham, UK
| | - Joseph Pagkalos
- Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, UK
| | - Branko Kopjar
- Royal Orthopaedic Hospital NHS Foundation Trust, Birmingham, UK.,School of Public Health, University of Washington, Seattle, Washington, USA
| |
Collapse
|
8
|
Abstract
Choice of articulating materials, head size and the design of the articulation will become decisive for the long-term performance of a total hip arthroplasty (THA) and especially in terms of risk for dislocation and wear-related problems. Here we account for common alternatives based on available studies and the evidence that can be derived from them.Metal or ceramic femoral heads articulating against a liner or cup made of highly cross-linked polyethylene and ceramic-on-ceramic articulations have about similar risk for complications leading to revision, whereas the performance of metal-on-metal articulations, especially with use of big heads, is inferior. The clinical significance of problems related to ceramic-on-ceramic articulations such as squeaking remains unclear. With use of current technology ceramic fractures are rare.Large femoral heads have the potential to increase the range of hip movement before impingement occurs and are therefore expected to reduce dislocation rates. On the other hand, issues related to bearing wear, corrosion at the taper-trunnion junction and groin pain may arise with larger heads and jeopardize the longevity of THA. Based on current knowledge, 32-mm heads seem to be optimal for metal-on-polyethylene bearings. Patients with ceramic-on-ceramic bearings may benefit from even larger heads such as 36 or 40 mm, but so far there are no long-term reports that confirm the safety of bearings larger than 36 mm.Assessment of lipped liners is difficult because randomized studies are lacking, but retrospective clinical studies and registry data seem to indicate that this liner modification will reduce the rate of dislocation or revision due to dislocation without clear evidence of clinically obvious problems due to neck-liner impingement.The majority of studies support the view that constrained liners and dual mobility cups (DMC) will reduce the risk of revision due to dislocation both in primary and revision THA, the latter gaining increasing popularity in some countries. Both these devices suffer from implant-specific problems, which seem to be more common for the constrained liner designs. The majority of studies of these implants suffer from various methodological problems, not least selection bias, which calls for randomized studies preferably in a multi-centre setting to obtain sufficient power. In the 2020s, the orthopaedic profession should place more effort on such studies, as has already been achieved within other medical specialties, to improve the level of evidence in the choice of articulation when performing one of the most common in-hospital surgical procedures in Europe. Cite this article: EFORT Open Rev 2020;5:763-775. DOI: 10.1302/2058-5241.5.200002.
Collapse
Affiliation(s)
- Georgios Tsikandylakis
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
| | - Soren Overgaard
- The Danish Hip Arthroplasty Register, Aarhus, Denmark
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
- Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Luigi Zagra
- Hip Department, IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - Johan Kärrholm
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden
- Region Västra Götaland, Sahlgrenska University Hospital, Department of Orthopaedics, Gothenburg, Sweden
- The Swedish Hip Arthroplasty Register, Gothenburg, Sweden
| |
Collapse
|
9
|
Yoon JY, Moon JK, Kim CH, Lee S, Yoon PW. Korean epidemiology and trends in hip joint replacements. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION 2020. [DOI: 10.5124/jkma.2020.63.8.462] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
This study aimed to analyze the epidemiologic characteristics of patients who underwent hip arthroplasty using the Korean nationwide database and investigate the recent trends in implant fixation methods and bearing surface selection. We aimed to compare clinical characteristics and differences with the results from the registry of other western countries. We analyzed the data collected by the Health Insurance Review and Assessment Service database of Korea from 2007 to 2011 and the Main Surgery Statistical Yearbook from 2014 to 2018, published by the National Health Insurance Service. The number and rate of patients who underwent hip joint arthroplasty per 10,000 persons have been steadily increasing since 2007. There was a big difference in mean age and preoperative diagnosis of patients between the bipolar hemiarthroplasty and total hip arthroplasty groups. Most patients underwent surgery using a cementless biological fixation method, and the cemented fixation method was selectively used for a small portion of old aged osteoporotic patients. In relation to the use of bearing surfaces, the registry data showed that ceramic-ceramic bearings were used at an overwhelmingly high rate (81%) in Korea compared to other countries. The reason was attributable to various factors, such as patient’s age or economic status, differences in the health insurance system between countries, and recently reported complications, such as ceramic fracture or noise.
Collapse
|
10
|
Langlois J, Hamadouche M. Recent update on crosslinked polyethylene in total hip arthroplasty. SICOT J 2020; 6:13. [PMID: 32412408 PMCID: PMC7227368 DOI: 10.1051/sicotj/2020013] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 04/23/2020] [Indexed: 02/02/2023] Open
Abstract
More than two decades after their clinical introduction, crosslinked polyethylenes (XLPE) have been widely adopted. Though concerns were initially raised regarding oxidation and brittleness, on a large scale, the first generation of XLPE continues to be highly effective 15 years after the surgery, even in a young and active population. Remelted XLPE might display lower wear rates than annealed XLPE. Second generation XLPEs, not only including sequentially irradiated and annealed but also associated with antioxidants, demonstrate encouraging short- to mid-term results. Registry data support clinical trial reports. Even in less favorable settings (lipped liners, dual mobility cups, revision surgery, hip resurfacing) results are promising. However, failures (fractures) have already been described. Therefore, a high level of surveillance remains crucial.
Collapse
Affiliation(s)
- Jean Langlois
-
Centre Orthopédique Santy 24, avenue Paul Santy 69008 Lyon France
-
Hôpital Privé Jean-Mermoz 55, avenue Jean-Mermoz 69008 Lyon France
| | - Moussa Hamadouche
-
Département de Chirurgie Orthopédique, Université Paris-Descartes, Assistance Publique-Hôpitaux de Paris, Hôpital Cochin 27, rue du Faubourg Saint-Jacques 75014 Paris France
| |
Collapse
|
11
|
Bartz-Johannessen C, Furnes O, Fenstad AM, Lie SA, Pedersen AB, Overgaard S, Kärrholm J, Malchau H, Mäkelä K, Eskelinen A, Wilkinson JM. Homogeneity in prediction of survival probabilities for subcategories of hipprosthesis data: the Nordic Arthroplasty Register Association, 2000-2013. Clin Epidemiol 2019; 11:519-524. [PMID: 31402836 PMCID: PMC6637139 DOI: 10.2147/clep.s199227] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2018] [Accepted: 04/08/2019] [Indexed: 11/23/2022] Open
Abstract
Introduction: The four countries in the Nordic Arthroplasty Register Association (NARA) share geographic proximity, culture, and ethnicity. Pooling data from different sources in order to obtain higher precision and accuracy of survival-probability estimates is appealing. Nevertheless, survival probabilities of hip replacements vary between the countries. As such, risk prediction for individual patients within countries may be problematic if data are merged. In this study, our primary question was to address when data merging for estimating prosthesis survival in subcategories of patients is advantageous for survival prediction of individual patients, and at what sample sizes this may be advised. Methods: Patients undergoing total hip replacements for osteoarthritis between January 1, 2000 and December 31, 2013 in the four Nordic countries were studied. A total of 184,507 patients were stratified into 360 patient subcategories based on country, age-group, sex, fixation, head size, and articulation. For each patient category, we determined the sample size needed from a single country to obtain a more accurate and precise estimate of prosthesis-survival probability at 5 and 10 years compared to an estimate using data from all countries. The comparison was done using mean-square error. Results: We found large variations in the sample size needed, ranging from 40 to 2,060 hips, before an estimate from a single Nordic country was more accurate and precise than estimates based on the NARA data. Conclusion: Using pooled survival-probability estimates for individual risk prediction may be imprecise if there is heterogeneity in the pooled data sources. By applying mean-square error, we demonstrate that for small sample sizes, applying the larger NARA database may provide a more accurate and precise estimate; however, this effect is not consistent and varies with the characteristics of the subcategory.
Collapse
Affiliation(s)
| | - Ove Furnes
- Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Anne Marie Fenstad
- Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Stein Atle Lie
- Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Dentistry, University of Bergen, Bergen, Norway
| | - Alma Becic Pedersen
- Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, Denmark
| | - Søren Overgaard
- Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopaedic Surgery and Traumatology Odense University Hospital and Institute of Clinical Research, University of Southern Denmark, Odense Denmark
| | - Johan Kärrholm
- Swedish Hip Arthroplasty Register, Department of Orthopaedics, Institute of Surgical Sciences, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Henrik Malchau
- Swedish Hip Arthroplasty Register, Department of Orthopaedics, Institute of Surgical Sciences, Sahlgrenska University Hospital, Gothenburg, Sweden.,Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, USA.,Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA, USA
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital, Turku, Finland.,Finnish Arthroplasty Register, Finnish Institute of Health, Helsinki, Finland
| | - Antti Eskelinen
- Finnish Arthroplasty Register, Finnish Institute of Health, Helsinki, Finland.,Department of Orthopaedics Surgery, Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Jeremy M Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| |
Collapse
|
12
|
Mäkelä KT, Furnes O, Hallan G, Fenstad AM, Rolfson O, Kärrholm J, Rogmark C, Pedersen AB, Robertsson O, W-Dahl A, Eskelinen A, Schrøder HM, Äärimaa V, Rasmussen JV, Salomonsson B, Hole R, Overgaard S. The benefits of collaboration: the Nordic Arthroplasty Register Association. EFORT Open Rev 2019; 4:391-400. [PMID: 31312523 PMCID: PMC6598612 DOI: 10.1302/2058-5241.4.180058] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The Nordic Arthroplasty Register Association (NARA) was established in 2007 by arthroplasty register representatives from Sweden, Norway and Denmark with the overall aim to improve the quality of research and thereby enhance the possibility for quality improvement with arthroplasty surgery. Finland joined the NARA collaboration in 2010. NARA minimal hip, knee and shoulder datasets were created with variables that all countries can deliver. They are dynamic datasets, currently with 25 variables for hip arthroplasty, 20 for knee arthroplasty and 20 for shoulder arthroplasty. NARA has published statistical guidelines for the analysis of arthroplasty register data. The association is continuously working on the improvement of statistical methods and the application of new ones. There are 31 published peer-reviewed papers based on the NARA databases and 20 ongoing projects in different phases. Several NARA publications have significantly affected clinical practice. For example, metal-on-metal total hip arthroplasty and resurfacing arthroplasty have been abandoned due to increased revision risk based on i.a. NARA reports. Further, the use of uncemented total hip arthroplasty in elderly patients has decreased significantly, especially in Finland, based on the NARA data. The NARA collaboration has been successful because the countries were able to agree on a common dataset and variable definitions. The collaboration was also successful because the group was able to initiate a number of research projects and provide answers to clinically relevant questions. A number of specific goals, set up in 2007, have been achieved and new one has emerged in the process.
Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180058
Collapse
Affiliation(s)
- Keijo T Mäkelä
- Turku University Hospital and University of Turku, Finland, and the Finnish Arthroplasty Register
| | - Ove Furnes
- Haukeland University Hospital, Bergen, Norway, and the Norwegian Arthroplasty Register
| | - Geir Hallan
- Haukeland University Hospital, Bergen, Norway, and the Norwegian Arthroplasty Register
| | - Anne Marie Fenstad
- Haukeland University Hospital, Bergen, Norway, and the Norwegian Arthroplasty Register
| | - Ola Rolfson
- Sahlgrenska University Hospital and University of Gothenburg, Sweden, and the Swedish Hip Arthroplasty Register
| | - Johan Kärrholm
- Sahlgrenska University Hospital and University of Gothenburg, Sweden, and the Swedish Hip Arthroplasty Register
| | - Cecilia Rogmark
- Department of Orthopedics, Skåne University Hospital, Department of Clinical Sciences Malmö, Lund University, and the Swedish Hip Arthroplasty Register, Sweden
| | - Alma Becic Pedersen
- Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, Denmark, and the Danish Hip Arthroplasty Register
| | - Otto Robertsson
- The Swedish Knee Arthroplasty Register, Department of Orthopedics, Skåne University Hospital, and Department of Clinical Sciences, Orthopedics, Lund University, Sweden
| | - Annette W-Dahl
- The Swedish Knee Arthroplasty Register, Department of Orthopedics, Skåne University Hospital, and Department of Clinical Sciences, Orthopedics, Lund University, Sweden
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Tampere, Finland, and the Finnish Arthroplasty Register
| | - Henrik M Schrøder
- Department of Orthopaedic Surgery, Naestved Hospital, Denmark, and the Danish Knee Arthroplasty Register
| | - Ville Äärimaa
- Turku University Hospital and University of Turku, Finland, and the Finnish Arthroplasty Register
| | - Jeppe V Rasmussen
- Department of Orthopaedic Surgery, Herlev Hospital, University of Copenhagen, Denmark, and the Danish Shoulder Arthroplasty Register
| | - Björn Salomonsson
- Department of Orthopedics, Karolinska Institutet, Danderyds Sjukhus AB, Sweden, and the Swedish Shoulder Arthroplasty Register
| | - Randi Hole
- Haukeland University Hospital, Bergen, Norway, and the Norwegian Arthroplasty Register
| | - Søren Overgaard
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Department of Clinical Research, University of Southern Denmark, and the Danish Hip Arthroplasty Register
| |
Collapse
|
13
|
Paxton EW, Cafri G, Nemes S, Lorimer M, Kärrholm J, Malchau H, Graves SE, Namba RS, Rolfson O. An international comparison of THA patients, implants, techniques, and survivorship in Sweden, Australia, and the United States. Acta Orthop 2019; 90:148-152. [PMID: 30739548 PMCID: PMC6461092 DOI: 10.1080/17453674.2019.1574395] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - International comparisons of total hip arthroplasty (THA) practices and outcomes provide an opportunity to enhance the quality of care worldwide. We compared THA patients, implants, techniques, and survivorship in Sweden, Australia, and the United States. Patients and methods - Primary THAs due to osteoarthritis were identified using Swedish (n = 159,695), Australian (n = 279,693), and US registries (n = 69,641) (2003-2015). We compared patients, practices, and implant usage across the countries using descriptive statistics. We evaluated time to all-cause revision using Kaplan-Meier survival curves. We assessed differences in countries' THA survival using chi-square tests of survival probabilities. Results - Sweden had fewer comorbidities than the United States and Australia. Cement fixation was used predominantly in Sweden and cementless in the United States and Australia. The direct anterior approach was used more frequently in the United States and Australia. Smaller head sizes (≤ 32 mm vs. ≥ 36 mm) were used more often in Sweden than the United States and Australia. Metal-on-highly cross-linked polyethylene was used more frequently in the United States and Australia than in Sweden. Sweden's 5- (97.8%) and 10-year THA survival (95.8%) was higher than the United States' (5-year: 97.0%; 10-year: 95.2%) and Australia (5-year: 96.3%; 10-year: 93.5%). Interpretation - Patient characteristics, surgical techniques, and implants differed across the 3 countries, emphasizing the need to adjust for demographics, surgical techniques, and implants and the need for global standardized definitions to compare THA survivorship internationally.
Collapse
Affiliation(s)
- Elizabeth W Paxton
- Department of Clinical Analysis, Surgical Outcomes and Analysis, Southern California Permanente Medical Group, San Diego, CA, USA; ,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; ,Correspondence:
| | - Guy Cafri
- Department of Clinical Analysis, Surgical Outcomes and Analysis, Southern California Permanente Medical Group, San Diego, CA, USA;
| | - Szilard Nemes
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden; ,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden;
| | - Michelle Lorimer
- Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, Australia;
| | - Johan Kärrholm
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden; ,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; ,Sahlgrenska University Hospital, Gothenburg, Sweden;
| | - Henrik Malchau
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden; ,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; ,Sahlgrenska University Hospital, Gothenburg, Sweden;
| | - Stephen E Graves
- Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, Australia;
| | - Robert S Namba
- Southern California Permanente Medical Group, Irvine, CA, USA
| | - Ola Rolfson
- Swedish Hip Arthroplasty Register, Gothenburg, Sweden; ,Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; ,Sahlgrenska University Hospital, Gothenburg, Sweden;
| |
Collapse
|
14
|
Westerman RW, Whitehouse SL, Hubble MJW, Timperley AJ, Howell JR, Wilson MJ. The Exeter V40 cemented femoral component at a minimum 10-year follow-up: the first 540 cases. Bone Joint J 2018; 100-B:1002-1009. [PMID: 30062940 DOI: 10.1302/0301-620x.100b8.bjj-2017-1535.r1] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims The aim of this study was to report the initial results of the Exeter V40 stem, which became available in 2000. Patients and Methods A total of 540 total hip arthroplasties (THAs) were performed in our unit using this stem between December 2000 and May 2002. Our routine protocol is to review patients postoperatively and at one, five, and ten years following surgery. Results A total of 145 patients (26.9%) died before ten years and of the remaining 395 stems, 374 (94.7%) remain in situ. A total of 21 well-fixed stems (5.3%) were revised. Ten were exchanged using a cement-in-cement technique to facilitate acetabular revision. Three were revised for infection, one for instability, one for fracture of the stem, and six following a periprosthetic fracture. An additional 16 acetabular components (4.1%) were revised; five for aseptic loosening and 11 for instability. There were no revisions for aseptic loosening of the stem, and no evidence of aseptic loosening in any hip. The fate of every stem is known and all patients remain under review. Survivorship, with revision of the stem for aseptic loosening as the endpoint, was 100%. At 13.5 years, the Kaplan-Meier survival rate for all-cause revision of the stem was 96.8% (95% confidence interval (CI) 94.8 to 98.8) and all-cause revision (including acetabular revision, infection, and instability) was 91.2% (95% CI 88.3 to 94.1). Conclusion Conclusion No stem was revised for aseptic loosening in this series. The contemporary Exeter V40 stem continues to perform well, and survival has remained comparable with that of the Exeter Universal stem. Cite this article: Bone Joint J 2018;100-B:1002-9.
Collapse
Affiliation(s)
- R W Westerman
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, UK
| | - S L Whitehouse
- Queensland University of Technology (QUT), Brisbane, Australia
| | - M J W Hubble
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, UK
| | - A J Timperley
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, UK
| | - J R Howell
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, UK
| | - M J Wilson
- Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter NHS Foundation Trust, Exeter, UK
| |
Collapse
|
15
|
de Steiger R, Lorimer M, Graves SE. Cross-Linked Polyethylene for Total Hip Arthroplasty Markedly Reduces Revision Surgery at 16 Years. J Bone Joint Surg Am 2018; 100:1281-1288. [PMID: 30063590 DOI: 10.2106/jbjs.17.01221] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total hip arthroplasty (THA) is an effective operation for the management of end-stage hip osteoarthritis, but long-term success can be limited by wear of the polyethylene bearing surface. Cross-linking conventional polyethylene has resulted in lower wear rates and a reduction in bone lysis in both laboratory and clinical studies. The aim of this study was to compare the rates of revision between cross-linked polyethylene (XLPE) and conventional non-cross-linked polyethylene (CPE) at 16 years after THAs performed for the treatment of osteoarthritis. METHODS We performed an observational study of data, from a national registry, on all patients who underwent THA for osteoarthritis in Australia from 1999 through December 31, 2016. The outcomes of THAs performed with CPE were compared with those of THAs performed with XLPE, along with an analysis of the effect of age, sex, femoral head size, the method of acetabular and femoral component fixation, and the reasons and types of revision. The principal outcome measure was the time to the first revision, determined using Kaplan-Meier estimates of survivorship. RESULTS CPE was used in 41,171 procedures, and XLPE was used in 199,131. The mean ages of the men and women treated with CPE were 70.0 years (standard deviation [SD] = 9.9 years) and 72.5 years (SD = 9.7 years), respectively, whereas the men and women who received XLPE were slightly younger (mean age, 68.6 years [SD = 10.3 years] and 70.7 years [SD = 9.9 years], respectively. XLPE was associated with a lower rate of revision than CPE at 6 months, and this difference became more apparent with time. The 16-year cumulative percentage of revisions of the primary THAs was 11.7% (95% confidence interval [CI] = 11.1% to 12.3%]) in the CPE group and 6.2% (95% CI = 5.7% to 6.7%) in the XLPE group. The hazard ratio at 9 years was 3.02 (p = 0.001). CONCLUSIONS The use of XLPE has resulted in a significant reduction in the rate of revision at 16 years following THA for osteoarthritis. This evidence suggests that the longevity of THA is likely to be improved, which may enable younger patients to undergo surgery, confident of a reduced need for revision in the long term. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- R de Steiger
- Australian Orthopaedic Association National Joint Replacement Registry, SAHMRI, Adelaide, South Australia, Australia.,School of Public Health, Faculty of Health and Medical Sciences, University of Adelaide, Adelaide, South Australia, Australia
| | - M Lorimer
- Australian Orthopaedic Association National Joint Replacement Registry, SAHMRI, Adelaide, South Australia, Australia
| | - S E Graves
- Australian Orthopaedic Association National Joint Replacement Registry, SAHMRI, Adelaide, South Australia, Australia
| |
Collapse
|
16
|
Affiliation(s)
- Ove Furnes
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen and Department of Clinical Medicine (K1), Faculty of Medicine, University of Bergen, Norway,
| |
Collapse
|