1
|
Hatamleh MM, Furuse AY. Bis-EMA/Bis-GMA ratio effects on resin-properties and impregnated fiber-bundles. Dent Mater 2024; 40:1652-1657. [PMID: 39084956 DOI: 10.1016/j.dental.2024.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Accepted: 07/09/2024] [Indexed: 08/02/2024]
Abstract
OBJECTIVES To evaluate the effect of different ratios of Bis-EMA/Bis-GMA resin mixtures on the inherent viscosity and curing-related properties: including degree of cure (DC%), shrinkage strain, Knoop micro-hardness (KH) and flexural strength of resin-impregnated fiber-bundles. METHODS Bis-EMA/Bis-GMA monomers were mixed (by weight) in the following ratios: M1 = 30 %/70 %, M2 = 50 %/50 %, M3 = 70 %/30 %, and M4 = 100 %/0 %. Standard measurements were made of refractive index, viscosity, degree of conversion, shrinkage strain and Knoop hardness (KHN). For 60 % glass fiber-bundles impregnated with 40 % resin, three-point bending test for flexural strength and shrinkage strain were measured. Data were analyzed by One-way ANOVA and Bonferroni post-hoc tests (α = 0.05). RESULTS For resin mixtures, increasing Bis-EMA proportion decreased refractive index (p < 0.05), and viscosity (p < 0.05), and increased monomer conversion (DC%), shrinkage strain and KHN (p < 0.05). DC% increased after 1 h for all resin mixtures. The shrinkage strain and flexural strength of resin-impregnated fiber-bundles reduced with increased Bis-EMA. SIGNIFICANCE Monomeric mixtures with highest amounts of Bis-EMA showed enhancement in several clinically-relevant properties and polymerization of respective resin-impregnated glass fibers. This makes them potential candidates for impregnating glass fibers in fiber-reinforced restorations.
Collapse
Affiliation(s)
- Muhanad M Hatamleh
- Department of Applied Dental Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, PO Box 3030, Irbid 22110, Jordan.
| | - Adilson Yoshio Furuse
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Al. Dr. Octávio Pinheiro Brisola - 9-75, Bauru, SP CEP 17012-901, Brazil
| |
Collapse
|
2
|
Menini M, Delucchi F, Bagnasco F, Baldi D, Canullo L, Setti P, Migliorati M, Simetti E, Pesce P. Shock Absorption Capacity of High-Performance Polymers for Dental Implant-Supported Restorations: In Vitro Study. Dent J (Basel) 2024; 12:111. [PMID: 38668023 PMCID: PMC11048904 DOI: 10.3390/dj12040111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 04/08/2024] [Accepted: 04/10/2024] [Indexed: 04/28/2024] Open
Abstract
BACKGROUND Restorative materials might significantly affect load transmission in peri-implant bone. The aim of the present study is to evaluate the shock absorption capacity of two different polymeric materials to be used for implant-supported prostheses. METHODS A masticatory robot was used to compare the shock absorption capacity of veneered and non-veneered polyetherketoneketone (PEKK), Pekkton®ivory (Cendres+Mètaux), and the glass fiber-reinforced composite (GFRC), TRINIATM (Bicon). Five identical sample crowns for each of the three groups were tested. Forces transmitted at the simulated peri-implant bone were recorded and statistically analyzed. RESULTS The statistical analysis of forces transmitted at the simulated dental implant revealed significant differences between the materials tested and between these materials and zirconia, glass ceramic, composite resin, and acrylic resin. Only differences between PEKK and veneered PEKK and between PEKK and one of the previously tested composite resins were not statistically significant. PEKK samples demonstrated significantly greater shock absorption capacity compared to GFRC. CONCLUSIONS PEKK revealed optimal shock absorption capacity. Further studies are needed to evaluate its efficacy in the case of long-span prostheses with reduced prosthetic volume.
Collapse
Affiliation(s)
- Maria Menini
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, 16132 Genova, Italy; (F.D.); (F.B.); (D.B.); (L.C.); (P.P.)
| | - Francesca Delucchi
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, 16132 Genova, Italy; (F.D.); (F.B.); (D.B.); (L.C.); (P.P.)
| | - Francesco Bagnasco
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, 16132 Genova, Italy; (F.D.); (F.B.); (D.B.); (L.C.); (P.P.)
| | - Domenico Baldi
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, 16132 Genova, Italy; (F.D.); (F.B.); (D.B.); (L.C.); (P.P.)
| | - Luigi Canullo
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, 16132 Genova, Italy; (F.D.); (F.B.); (D.B.); (L.C.); (P.P.)
| | | | - Marco Migliorati
- Orthodontic Division, Department of Surgical Sciences (DISC), University of Genova, 16132 Genova, Italy;
| | - Enrico Simetti
- Department of Informatics, Bioengineering, Robotics and Systems Engineering (DIBRIS), University of Genova, 16132 Genova, Italy
| | - Paolo Pesce
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences (DISC), University of Genova, 16132 Genova, Italy; (F.D.); (F.B.); (D.B.); (L.C.); (P.P.)
| |
Collapse
|
3
|
De Giorgis L, Pesce P, Barberis F, Lagazzo A, Pera F, Baldi D, Canullo L, Menini M. Fiber-Reinforced Composites for Full-Arch Implant-Supported Rehabilitations: An In Vitro Study. J Clin Med 2024; 13:2060. [PMID: 38610826 PMCID: PMC11012982 DOI: 10.3390/jcm13072060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 03/07/2024] [Accepted: 03/28/2024] [Indexed: 04/14/2024] Open
Abstract
Background: Fiber-reinforced composites (FRCs) have been proposed as an alternative to traditional metal alloys for the realization of frameworks in full-arch implant-supported prostheses. The aim of the present in vitro study was to evaluate the deflection under load of seven prostheses endowed with frameworks made of different materials, including different types of fiber-reinforced composites (FRCs). Methods: A master cast with four implant analogues in correspondence with the two lateral incisors and the two first molars was used to create full-arch fixed prostheses with the same shape and different materials. Prostheses were made of the following different materials (framework+veneering material): gold alloy+resin (Au+R), titanium+resin (Ti+R), FRC with multidirectional carbon fibers+resin (ICFRC+AR), FRC with unidirectional carbon fibers+composite (UCFRC+C), FRC with glass fibers+resin (GFRC+AR), FRC with glass fibers+composite (GFRC+C), and resin (R, fully acrylic prosthesis). Flexural tests were conducted using a Zwick/Roell Z 0.5 machine, and the deflection of the lower surface of the prosthesis was measured in order to obtain load/deflection graphs. Results: Greater rigidity and less deflection were recorded for UCFRC+C and GFRC+C, followed by Ti+R and Au+R. The greatest deformations were observed for resin alone, ICFRC+R, and GFRC+R. The results were slightly different in the incisal region, probably due to the greater amount of veneering material in this area. Conclusions: When used to realize full-arch frameworks, Au and Ti allow for predictable mechanical behavior with gradual deformations with increasing load. UCFRC also demonstrated good outcomes and less deflection than ICFRCs when loaded. The GFRC full-arch framework may be a valid alternative, although it showed greater deflections. Further studies are needed in order to evaluate how different prosthesis designs and material thicknesses might affect the outcomes.
Collapse
Affiliation(s)
- Luisa De Giorgis
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences, University of Genova, Largo R. Benzi 10, 16132 Genova, Italy; (L.D.G.); (P.P.); (D.B.); (M.M.)
| | - Paolo Pesce
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences, University of Genova, Largo R. Benzi 10, 16132 Genova, Italy; (L.D.G.); (P.P.); (D.B.); (M.M.)
| | - Fabrizio Barberis
- Department of Civil, Chemical and Environmental Engineering, University of Genoa, Via Opera Pia 15, 16145 Genova, Italy (A.L.)
| | - Alberto Lagazzo
- Department of Civil, Chemical and Environmental Engineering, University of Genoa, Via Opera Pia 15, 16145 Genova, Italy (A.L.)
| | - Francesco Pera
- CIR Dental School, Department of Surgical Sciences, University of Turin, 10126 Torino, Italy;
| | - Domenico Baldi
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences, University of Genova, Largo R. Benzi 10, 16132 Genova, Italy; (L.D.G.); (P.P.); (D.B.); (M.M.)
| | - Luigi Canullo
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences, University of Genova, Largo R. Benzi 10, 16132 Genova, Italy; (L.D.G.); (P.P.); (D.B.); (M.M.)
| | - Maria Menini
- Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences, University of Genova, Largo R. Benzi 10, 16132 Genova, Italy; (L.D.G.); (P.P.); (D.B.); (M.M.)
| |
Collapse
|
4
|
Fouquet V, Larsen N, Stchepinsky AC, Vennat E, Benoit A, Tapie L. A parametrical finite element analysis for functionally graded material overlay restoration. J Mech Behav Biomed Mater 2024; 152:106409. [PMID: 38277910 DOI: 10.1016/j.jmbbm.2024.106409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 01/13/2024] [Accepted: 01/15/2024] [Indexed: 01/28/2024]
Abstract
The main cause of failure in bonded ceramic restorations is material fracture due to excessive stress concentration at the base of the prosthesis. The design of restorative functionally graded materials (FGM) could represent a major advance in dissipating mechanical stresses during occlusal contacts. The aim of this paper is to carry out a complete factorial design of finite element analyses to optimize a multilayer FGM introduced at the bottom of an overlay prosthesis. The number and thickness of layers vary within a spectrum compatible with ceramic shaping processes whereas Young's moduli variations are set in the range of dental tissues. For a 1.5-mm thick prosthesis, the optimal FGM configuration appears to be a 5 layers of 0.2 mm thickness with a linear distribution of Young's modulus from 30 to 70 GPa. This configuration was implemented in a 3D model of a restored tooth with realistic geometry to validate the proof-of-concept.
Collapse
Affiliation(s)
- Vincent Fouquet
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France; Université Sorbonne Paris Nord, F-93430, Villetaneuse, France; AP-HP, Louis-Mourier Hospital, Oral Medecine Department, F-92700, Colombes, France
| | - Nicoline Larsen
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France
| | | | - Elsa Vennat
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France; Université Paris-Saclay, CentraleSupélec, ENS Paris-Saclay, CNRS, LMPS - Laboratoire de Mécanique Paris-Saclay, 91190, Gif sur Yvette, France
| | - Aurélie Benoit
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France.
| | - Laurent Tapie
- Université Paris Cité, Université Sorbonne Paris Nord, URB2i, F-92120, Montrouge, France; EPF Engineering School, F-94230, Cachan, France.
| |
Collapse
|
5
|
Liang X, Yu B, Ye L, Lin D, Zhang W, Zhong HJ, He J. Recent Advances in Quaternary Ammonium Monomers for Dental Applications. MATERIALS (BASEL, SWITZERLAND) 2024; 17:345. [PMID: 38255513 PMCID: PMC10820831 DOI: 10.3390/ma17020345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 12/30/2023] [Accepted: 01/08/2024] [Indexed: 01/24/2024]
Abstract
Resin-based dental materials have been one of the ideal choices among various materials in the treatment of dental caries. However, resin-based dental materials still have some drawbacks, such as the lack of inherent antibacterial activity. Extensive research has been conducted on the use of novel quaternary ammonium monomers (QAMs) to impart antibacterial activity to dental materials. This review provides a comprehensive overview of the recent advances in quaternary ammonium monomers (QAMs) for dental applications. The current progress and limitations of QAMs are discussed based on the evolution of their structures. The functional diversification and enhancement of QAMs are presented. QAMs have the potential to provide long-term antibacterial activity in dental resin composites, thereby prolonging their service life. However, there is a need to balance antibacterial performance with other material properties and the potential impact on the oral microbiome and general health. Finally, the necessity for further scientific progress in the development of novel quaternary ammonium monomers and the optimization of dental resin formulations is emphasized.
Collapse
Affiliation(s)
- Xiaoxu Liang
- Foundation Department, Guangzhou Maritime University, Guangzhou 510725, China;
| | - Biao Yu
- School of Chemistry and Chemical Engineering, Lingnan Normal University, Zhanjiang 524048, China;
| | - Liuqi Ye
- International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China; (L.Y.); (D.L.); (W.Z.)
| | - Danlei Lin
- International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China; (L.Y.); (D.L.); (W.Z.)
| | - Wen Zhang
- International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China; (L.Y.); (D.L.); (W.Z.)
| | - Hai-Jing Zhong
- International Cooperative Laboratory of Traditional Chinese Medicine Modernization and Innovative Drug Development of Chinese Ministry of Education (MOE), College of Pharmacy, Jinan University, Guangzhou 510632, China; (L.Y.); (D.L.); (W.Z.)
| | - Jingwei He
- School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641, China
| |
Collapse
|
6
|
Inan A, Gonca M. Effects of aligner activation and power arm length and material on canine displacement and periodontal ligament stress: a finite element analysis. Prog Orthod 2023; 24:40. [PMID: 38008884 PMCID: PMC10678869 DOI: 10.1186/s40510-023-00492-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 09/16/2023] [Indexed: 11/28/2023] Open
Abstract
BACKGROUND This study aimed to assess the impact of aligner activation and power arm length and material on canine and aligner displacement, von Mises stress in the power arm, and principal stress in the periodontal ligament (PDL) during canine tooth distalization using finite element analysis (FEA). The effects of aligner activation and power arm length were primary outcomes, while the effect of the power arm material was a secondary outcome. METHODS Aligner activation (0.1 mm or 0.2 mm) was applied without using a power arm in two models. The effects of aligner activation, power arm length (12, 13, or 14 mm) and power arm material (stainless steel [SS] or fiber-reinforced composite [FRC]) on canine distalization were investigated in 12 models by evaluating displacement and stress via ALTAIR OptiStruct analysis. RESULTS Greater canine displacement was observed in all models with 0.2 mm than 0.1 mm of aligner activation. When models with the same aligner activation were compared, reduced mesiodistal tipping, increased palatal tipping, and increased extrusion of the canine cusp were observed with increasing power arm length. Moreover, the von Mises stress increased as the power arm length increased. Increasing the aligner activation and power arm length increased the maximum principal stress in the PDL. Power arms of the same length in both materials showed the same results in terms of canine displacement, clear aligner displacement, and maximum principal stress in the PDL. However, under conditions of equal length and aligner activation, the von Mises stress of the SS power arm was higher than that of the FRC power arm. CONCLUSION Using a power arm in canine distalization reduced mesiodistal tipping but increased palatal tipping and extrusion of the canine cusp. Aligner activation and additional force increased tooth movement and principal stress in the canine PDL. FRC power arms exhibited less von Mises stress than SS power arms.
Collapse
Affiliation(s)
| | - Merve Gonca
- Department of Orthodontics, Faculty of Dentistry, Recep Tayyip Erdoğan University, Rize, Turkey.
| |
Collapse
|
7
|
Sinha N, Thompson GA, Drago C, An H. Shear bond strength characteristics on surface treatment modalities of CAD-CAM resin polymers. J Prosthodont 2023. [PMID: 37940565 DOI: 10.1111/jopr.13790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 11/05/2023] [Indexed: 11/10/2023] Open
Abstract
PURPOSE The purpose of this in vitro study was to analyze the shear bond strength of composite resin to a commercially available high-performance polymer material for fixed, screw-retained full arch restorations. MATERIAL AND METHODS A total of 135 computer-aided design and computer-aided manufacturing, high-performance polymer (HPP) blocks were cut and obtained from discs (Trilor 95, Harvest Dental, Brea, CA). The samples were 10 mm × 10 mm × 10 mm. The specimen surfaces were grouped as untreated (Group A), 50 μm Al2O3 (Group B), 110 μm Al2O3 (Group C), Rocatec (3 M, St. Paul, MN) activated with silica-modified alumina oxide treatment (Group D); and trimmed coarsely with a carbide bur (Group E). Group A samples were used as controls. After surface treatments, the specimens were gently cleansed with oil-free steam and alcohol wipes. Surface conditioning was performed on all physically treated samples. The manufacturer's recommendations were followed for bonding composite resin to the samples with light-cured Visio.link (Bredent, Chesterfield, UK). Cylinders were veneered with composite resins (diameter 5 mm, height 4 mm) and polymerized on the specimen surfaces through plastic tubes. Twenty-seven specimens were used for each testing group and aging tests were performed. The experimental samples were thermocycled. Shear bond strength and scanning electron microscopic tests were performed. Means and standard deviations were calculated. Statistical analysis was performed with post-hoc Tukey tests. RESULTS Statistical analysis revealed that there was a significant difference between the groups (p<0.001). The highest shear bond strengths were achieved for the specimens bonded with Visio.link without physical surface treatments (270.47 MPa). The lowest bond strengths were found for specimen surfaces abraded with 110 μm Al2O3 (117.03 Mpa) CONCLUSIONS: The results of this laboratory study indicated that the specimens used with Visio.link as provided by the manufacturer had the highest shear bond strengths between the composite resin and high-performance polymer test specimens. Modifications of the high-performance polymer surfaces with carbide burs did not change bonding strengths with the composite materials.
Collapse
Affiliation(s)
- Nikita Sinha
- Department of Prosthodontics, Creighton University School of Dentistry, Omaha, Nebraska, USA
| | - Geoffrey A Thompson
- Department of Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wisconsin, USA
| | - Carl Drago
- Department of Prosthodontics, Marquette University School of Dentistry, Milwaukee, Wisconsin, USA
| | - Hongseok An
- Department of Restorative Dentistry, Graduate Prosthodontics OHSU, Portland, Oregon, USA
| |
Collapse
|
8
|
Kuusisto N, Abushahba F, Syrjänen S, Huumonen S, Vallittu P, Närhi T. Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study. Dentomaxillofac Radiol 2023; 52:20230252. [PMID: 37641961 DOI: 10.1259/dmfr.20230252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/31/2023] Open
Abstract
OBJECTIVES Three-dimensional cone beam computed tomography (CBCT) imaging can be considered, especially in patients with complicated peri-implantitis (PI). Artifacts induced by dense materials are the drawback of CBCT imaging and the peri-implant bone condition may not be assessed reliably because the artifacts are present in the same area. This pilot study investigates the performance of the artifact reduction algorithm (ARA) of the Planmeca Viso G7 CBCT device (Planmeca, Helsinki, Finland) with three different implant materials and imaging parameters. METHODS Three pairs of dental implants consisting of titanium, zirconia, and fiber reinforced composite (FRC) were set into a pig mandible. A vertical defect simulating peri-implantitis bone loss was made on the buccal side of one of each implant. The defect was identified and measured by two observers and compared to the actual dimensions. In addition, the bone structure and the marginal cortex visibility between the implants were estimated visually. RESULTS The bone defect and its dimensions with the zirconia implant could not be identified in any image with or without the metal artifact reduction algorithm. The bone defect of titanium and FRC implants were identified with all three imaging parameters or even without ARA. The interobserver agreement between the two observers was almost perfect for all categories analyzed. CONCLUSION Peri-implantitis defect of the zirconia implant and the peri-implant bone structure of the zirconia implants cannot be recognized reliably with any ARA levels, or any imaging parameters used with the Planmeca Viso G7. The need for ARA when imaging the peri-implant bone condition of the titanium and FRC implants may be unnecessary.
Collapse
Affiliation(s)
- Niina Kuusisto
- Department of Oral Pathology and Radiology, Institute of Dentistry, University of Turku, Turku, Finland
- Department of Radiology, Päijät-Häme Central Hospital, Lahti, Finland
| | - Faleh Abushahba
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland
| | - Stina Syrjänen
- Department of Oral Pathology and Radiology, Institute of Dentistry, University of Turku, Turku, Finland
| | - Sisko Huumonen
- Institute of Dentistry, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Pekka Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- Welfare Division, City of Turku, Turku, Finland
| | - Timo Närhi
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland
| |
Collapse
|
9
|
Escobar LB, Pereira da Silva L, Manarte-Monteiro P. Fracture Resistance of Fiber-Reinforced Composite Restorations: A Systematic Review and Meta-Analysis. Polymers (Basel) 2023; 15:3802. [PMID: 37765654 PMCID: PMC10537351 DOI: 10.3390/polym15183802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/08/2023] [Accepted: 09/15/2023] [Indexed: 09/29/2023] Open
Abstract
Composite resin is universally used for posterior teeth restorations. Fibers have been suggested for the mechanical improvement of the restorations. This study assessed the fracture resistance of class II fiber-reinforced composite restorations and compared it with the fracture resistance of three control groups: (1) healthy teeth, (2) non-fiber-reinforced restorations and (3) unrestored cavities. A search was performed using PubMed, Web of Science and Google Scholar from 15 May to 12 June 2023. Only in vitro studies from the last 10 years were included for this systematic analysis. This study was registered in the PROSPERO database, it followed PRISMA guidelines and the risk of bias was assessed using the QUIN tool. Fracture resistance median values, in Newtons (N), were calculated for the experimental and control groups (95% confidence interval). For pairwise comparison, nonparametric tests (p < 0.05) were applied. Twenty-four in vitro studies met the inclusion criteria. The fracture resistance of the experimental group was 976.0 N and differed (p < 0.05) from all controls. The experimental group showed lower values of fracture resistance than healthy teeth (1459.9 N; p = 0.048) but higher values than non-fiber-reinforced restorations (771.0 N; p = 0.008) and unrestored cavities (386.6 N; p < 0.001). In vitro systematic outcomes evidenced that glass and/or polyethylene fibers improved the fracture resistance of composite restorations.
Collapse
Affiliation(s)
| | - Lígia Pereira da Silva
- FP-I3ID, Faculty of Health Sciences, University Fernando Pessoa, 4200-150 Porto, Portugal; (L.B.E.); (P.M.-M.)
| | | |
Collapse
|
10
|
Güzelce S E. Biomechanical comparison of different framework materials in mandibular overdenture prosthesis supported with implants of different sizes: a finite element analysis. BMC Oral Health 2023; 23:450. [PMID: 37408011 DOI: 10.1186/s12903-023-03080-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Accepted: 05/25/2023] [Indexed: 07/07/2023] Open
Abstract
BACKGROUND The aim of this study is to evaluate the stresses on the supporting bone, implants, and framework materials under masticatory forces in mandibular overdenture prostheses modeled with different framework materials and different implant types, using the Finite Element Analysis (FEA). METHODS For the finite element modeling, two identical mandibular jaw models were created; one with two standard (diameter:4.1 mm/12 mm length) and the other with two mini-implants (diameter:2.4 mm/12 mm length) were placed in the canine teeth area. The polymethylmethacrylate (PMMA) denture was modeled upon them, supported by Cobalt Chromium alloy (CoCr), Poly-ether ether ketone (PEEK), and Zantex materials with framework. No framework was added as a control model; only PMMA overdenture prosthesis was modeled. RESULTS Regardless of the framework materials of the overdenture prostheses, the stress values on mini-implants in all models yielded approximately two times higher results comparing to standard implants. More stress transmission was observed in the supporting bone and implants in the control prostheses and overdenture prostheses supported with respectively PEEK, Zantex, CoCr alloy frameworks, respectively. In the framework materials, more stress occurred on CoCr, Zantex and PEEK in that order. CONCLUSION In the light of this study, the use of mini-implants as an alternative to standard implants is not promising in terms of distribution and transmission of chewing stresses. As a framework material, standard rigid metal alloys were found to be more advantageous than polymer materials in terms of stress distribution.
Collapse
Affiliation(s)
- Elifnur Güzelce S
- Department of Prosthodontics, University of Health Sciences Turkey, Hamidiye Campus (Istanbul) Selimiye Mah. Tıbbiye Cad. No:38, Üsküdar/Istanbul, 34668, Türkiye.
| |
Collapse
|
11
|
Maletin A, Ristić I, Nešić A, Knežević MJ, Koprivica DĐ, Cakić S, Ilić D, Milekić B, Puškar T, Pilić B. Development of Light-Polymerized Dental Composite Resin Reinforced with Electrospun Polyamide Layers. Polymers (Basel) 2023; 15:2598. [PMID: 37376244 DOI: 10.3390/polym15122598] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 06/01/2023] [Accepted: 06/02/2023] [Indexed: 06/29/2023] Open
Abstract
As the mechanical properties of resin-based dental composite materials are highly relevant in clinical practice, diverse strategies for their potential enhancement have been proposed in the extant literature, aiming to facilitate their reliable use in dental medicine. In this context, the focus is primarily given to the mechanical properties with the greatest influence on clinical success, i.e., the longevity of the filling in the patient's mouth and its ability to withstand very strong masticatory forces. Guided by these objectives, the goal of the present study was to ascertain whether the reinforcement of dental composite resins with electrospun polyamide (PA) nanofibers would improve the mechanical strength of dental restoration materials. For this purpose, light-cure dental composite resins were interspersed with one and two layers comprising PA nanofibers in order to investigate the influence of such reinforcement on the mechanical properties of the resulting hybrid resins. One set of the obtained samples was investigated as prepared, while another set was immersed in artificial saliva for 14 days and was subsequently subjected to the same set of analyses, namely Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and differential scanning calorimetry (DSC). Findings yielded by the FTIR analysis confirmed the structure of the produced dental composite resin material. They also provided evidence that, while the presence of PA nanofibers did not influence the curing process, it strengthened the dental composite resin. Moreover, flexural strength measurements revealed that the inclusion of a 16 μm-thick PA nanolayer enabled the dental composite resin to withstand a load of 3.2 MPa. These findings were supported by the SEM results, which further indicated that immersing the resin in saline solution resulted in a more compact composite material structure. Finally, DSC results indicated that as-prepared as well as saline-treated reinforced samples had a lower glass transition temperature (Tg) compared to pure resin. Specifically, while pure resin had a Tg of 61.6 °C, each additional PA nanolayer decreased the Tg by about 2 °C, while the further reduction was obtained when samples were immersed in saline for 14 days. These results show that electrospinning is a facile method for producing different nanofibers that can be incorporated into resin-based dental composite materials to modify their mechanical properties. Moreover, while their inclusion strengthens the resin-based dental composite materials, it does not affect the course and outcome of the polymerization reaction, which is an important factor for their use in clinical practice.
Collapse
Affiliation(s)
| | - Ivan Ristić
- Faculty of Technology, University of Novi Sad, 21000 Novi Sad, Serbia
| | - Aleksandra Nešić
- Faculty of Technology, University of Novi Sad, 21000 Novi Sad, Serbia
| | | | | | - Suzana Cakić
- Faculty of Technology, University of Niš, 16000 Leskovac, Serbia
| | - Dušica Ilić
- Faculty of Electronic Engineering, University of Niš, 18000 Niš, Serbia
| | - Bojana Milekić
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia
| | - Tatjana Puškar
- Faculty of Medicine, University of Novi Sad, 21000 Novi Sad, Serbia
| | - Branka Pilić
- Faculty of Technology, University of Novi Sad, 21000 Novi Sad, Serbia
| |
Collapse
|
12
|
Khan AA, Zafar MS, Fareed MA, AlMufareh NA, Alshehri F, AlSunbul H, Lassila L, Garoushi S, Vallittu PK. Fiber-reinforced composites in dentistry - An insight into adhesion aspects of the material and the restored tooth construct. Dent Mater 2023; 39:141-151. [PMID: 36604257 DOI: 10.1016/j.dental.2022.12.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 12/05/2022] [Accepted: 12/24/2022] [Indexed: 01/04/2023]
Abstract
OBJECTIVE This review aimed to highlight the insight into adhesion aspects within the components of the glass FRC (i.e., fiber and matrix) and between resin luting material and the glass FRC construction. METHODS The fundamentals of semi-interpenetrating polymer network (semi-IPN) based FRCs and their advantages in forming a solid adhesive interface with indirect FRC restoration, dental adhesive, and luting cement are elaborated. The important resin matrix systems and glass fibers used in FRCs are discussed. This is principally based on a survey of the literature over Medline/PubMed, Web of Science, and Scopus databases and a review of the relevant studies and publications in scientific papers in international peer-reviewed journals for the specific topic of biomaterials science. The keywords used for the search approach were: adhesion, fiber-reinforced composite, glass fiber, and semi-interpenetrating polymer network. RESULTS The polymer matrix systems of semi-IPN-based FRCs and formation of secondary-IPN layer are pivotal for bonding of multiphasic indirect dental constructs and repair. Additionally, describing areas of indication for FRCs in dentistry, explaining the adhesion aspects of FRC for the cohesion of the material itself, and for obtaining durable adhesion when the FRC construct is luted to tooth and remaining dentition. Current progress in the field of FRC research and future directions are summarized and presented. SIGNIFICANCE By understanding the isotropic-anisotropic nature of fibers and the interfacial adhesion within the components of the FRC; between resin cement and the FRC construction, the clinically successful FRC-based multiphasic indirect tooth construct can be achieved. The interfacial adhesion within the components of the FRC and between resin luting material and the FRC construction play a key role in adhesion-based unibody dental restorations.
Collapse
Affiliation(s)
- Aftab Ahmed Khan
- Dental Biomaterials Research Chair, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
| | - Muhammad Sohail Zafar
- Department of Restorative Dentistry, College of Dentistry, Taibah University, Al Madinah, Al Munawwarah, Medina, Saudi Arabia; Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad, Pakistan
| | - Muhammad Amber Fareed
- Department of Restorative Dentistry, College of Dentistry, Gulf Medical University, Ajman, United Arab Emirates
| | - Nawaf Abdulrahman AlMufareh
- Department of Pediatric Dentistry and Special Health Care Needs, Ministry of Health, Abha Specialist Dental Center, Abha, Saudi Arabia
| | - Faisal Alshehri
- Department of Restorative Sciences, School of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Hanan AlSunbul
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterials Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Pekka Kalevi Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland; City of Turku Welfare Division, Oral Health Care, Turku, Finland
| |
Collapse
|
13
|
He J, Lassila L, Garoushi S, Vallittu P. Tailoring the monomers to overcome the shortcomings of current dental resin composites - review. Biomater Investig Dent 2023; 10:2191621. [PMID: 37090482 PMCID: PMC10120559 DOI: 10.1080/26415275.2023.2191621] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023] Open
Abstract
Dental resin composites (DRCs) have become the first choice among different restorative materials for direct anterior and posterior restorations in the clinic. Though the properties of DRCs have been improved greatly in recent years, they still have several shortcomings, such as volumetric shrinkage and shrinkage stress, biofilm development, lack of radio-opacity for some specific DRCs, and estrogenicity, which need to be overcome. The resin matrix, composed of different monomers, constitutes the continuous phase and determine the performance of DRCs. Thus, the chemical structure of the monomers plays an important role in modifying the properties of DRCs. Numerous researchers have taken to design and develop novel monomers with specific functions for the purpose of fulfilling the needs in dentistry. In this review, the development of monomers in DRCs were highlighted, especially focusing on strategies aimed at reducing volumetric shrinkage and shrinkage stress, endowing bacteriocidal and antibacterial adhesion activities as well as protein-repelling activity, increasing radio-opacity, and replacing Bis-GMA. The influences of these novel monomers on the properties of DRCs were also discussed.
Collapse
Affiliation(s)
- Jingwei He
- College of Materials Science and Engineering, South China University of Technology, Guangzhou, China
- Department of Biomaterials Science and Turku Clinical Biomaterials Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- CONTACT Jingwei He College of Materials Science and Engineering, South China University of Technology, Guangzhou, China
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterials Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Pekka Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- Wellbeing Services County of South-West Finland, Turku, Finland
| |
Collapse
|
14
|
Chattrairat A, Kandare E, Aimmanee S, Tran P, Das R. Development and characterisation of hybrid composite skin simulants based on short polyethylene fibre and bioactive glass particle-reinforced silicone. J Mech Behav Biomed Mater 2022; 136:105424. [PMID: 36283299 DOI: 10.1016/j.jmbbm.2022.105424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 08/16/2022] [Accepted: 08/17/2022] [Indexed: 11/30/2022]
Abstract
Silicone elastomers are widely recognised as artificial skins for medical prosthesis and cranial injury assessment. Since silicone is not an ideal skin simulant due to the lack of mechanical stiffness and a fibrous structure, the present study aimed to tailor the mechanical and structural characteristics of silicone by integrating biocompatible reinforcements (namely, short polyethylene fibres and bioglass particles) to develop suitable bio-integrative skin simulant candidates. The influences of short polyethylene fibres and bioglass particles in the selected platinum silicone on the mechanical properties of silicone-based composite skin simulants were investigated with various factors, including filler concentration, KMnO4 surface treatment of the polyethylene fibre, and particle size. A comprehensive assessment of the tensile, compressive, and hardness properties of the examined composites was conducted, and they were compared with the properties of human biological skin. The results exhibited that the elastic moduli and the hardness of all composites increased with the concentration of both reinforcements. While integrating only the bioglass particles had the advantage of an insignificant effect on the hardness change of the silicone matrix, the composite with polyethylene fibres possessed superior tensile elastic modulus and tensile strength compared to those of the bioglass reinforced composite. The composites with 5% untreated polyethylene fibres, KMnO4 surface-treated fibres, and bioglass reinforcements enhanced the tensile elastic moduli from the pure silicone up to 32%, 44%, and 22%, respectively. It reflected that the surface treatment of the fibres promotes better interfacial adhesion between the silicone matrix and the fibres. Moreover, the smaller bioglass particle had a greater mechanical contribution than the larger glass particle. Systematically characterised for the first time, the developed composite skin simulants demonstrated essential mechanical properties within the range of the human skin and constituted better skin alternatives than pure silicone for various biomedical applications.
Collapse
Affiliation(s)
- Akanae Chattrairat
- School of Engineering, RMIT University, GPO Box 2476, Melbourne, Victoria, 3001, Australia.
| | - Everson Kandare
- School of Engineering, RMIT University, GPO Box 2476, Melbourne, Victoria, 3001, Australia
| | - Sontipee Aimmanee
- Advanced Materials and Structures Laboratory, Department of Mechanical Engineering, Faculty of Engineering, King Mongkut's University of Technology, Thonburi, Thailand
| | - Phuong Tran
- School of Engineering, RMIT University, GPO Box 2476, Melbourne, Victoria, 3001, Australia
| | - Raj Das
- School of Engineering, RMIT University, GPO Box 2476, Melbourne, Victoria, 3001, Australia
| |
Collapse
|
15
|
Kumar S, Bhowmik S. Potential use of natural fiber-reinforced polymer biocomposites in knee prostheses: a review on fair inclusion in amputees. IRANIAN POLYMER JOURNAL 2022. [DOI: 10.1007/s13726-022-01077-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
16
|
Zhang S, Liao M, Liu F, Huang X, Mai S, He J. Preparation of Bis-GMA free dental resin composites with anti-adhesion effect against Streptococcus mutans using synthesized fluorine-containing methacrylate (DFMA). J Mech Behav Biomed Mater 2022; 131:105263. [DOI: 10.1016/j.jmbbm.2022.105263] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Revised: 04/26/2022] [Accepted: 05/01/2022] [Indexed: 12/21/2022]
|
17
|
Sunarintyas S, Siswomihardjo W, Tsoi JK, Matinlinna JP. Biocompatibility and mechanical properties of an experimental E-glass fiber-reinforced composite for dentistry. Heliyon 2022; 8:e09552. [PMID: 35711989 PMCID: PMC9192806 DOI: 10.1016/j.heliyon.2022.e09552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 03/04/2022] [Accepted: 05/23/2022] [Indexed: 11/25/2022] Open
Abstract
Objectives To evaluate the biocompatibility and mechanical properties of experimental bis-phenol-A and bis-GMA free E-glass fiber-reinforced composites (FRCs) prepared with hexanediol dimethacrylate (HDDMA) based resin. Methods Two ratios of HDDMA/TEGDMA resin were evaluated: exp-1 (70/30 wt.%) and exp-2 (50/50 wt.%) with two bis-GMA resin control groups (bis-GMA/MMA and bis-GMA/TEGDMA resins, both 70/30 wt.%). E-glass fibers were embedded into the resins to prepare FRCs specimens. Biocompatibility was assessed for cytoviability and biofilm formation with Streptococcus mutans, Streptococcus sanguinis, Enterococcus faecalis, and Candida albicans. Mechanical properties were evaluated for flexural strength and hardness (24 h, water storage 1 and 28 days), water sorption (1, 7, 14, and 28 days), contact angle, and surface roughness. The data were analyzed statistically by one-way and two-way ANOVA (p < 0.05). Results Cytoviability of the experimental groups was significantly higher than the control groups (p < 0.05). The exp-1 cytoviability (98.2 ± 1.3%) met the ISO 10993-5 standard requirement for noncytotoxic materials. The adherence of bacteria to the experimental FRCs was visibly less than the controls, while Candida albicans adhered visibly more to the experimental groups than the controls (p < 0.05). Flexural strength showed slightly higher values for controls than for the experimental groups. The exp-1 hardness value was significantly higher in the control groups for all storage conditions (p < 0.05). The water sorption of the experimental groups was significantly higher than the controls. The surface roughness indicated no significant difference (p = 0.87). The exp-1 showed a higher contact angle with the control groups. Conclusion The experimental HDDMA/TEGDMA-based FRCs might be potential alternatives for bis-GMA-based FRCs. Clinical significance The HDDMA/TEGDMA E-glass FRCs might provide biocompatible restorations.
Collapse
Affiliation(s)
- Siti Sunarintyas
- Dental Biomaterial Department, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia
| | - Widowati Siswomihardjo
- Dental Biomaterial Department, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta, Indonesia
| | - James K.H. Tsoi
- Dental Materials Science, Applied Oral Sciences & Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Jukka P. Matinlinna
- Dental Materials Science, Applied Oral Sciences & Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
- Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, United Kingdom
| |
Collapse
|
18
|
Sailer I, Karasan D, Todorovic A, Ligoutsikou M, Pjetursson BE. Prosthetic failures in dental implant therapy. Periodontol 2000 2022; 88:130-144. [PMID: 35103329 PMCID: PMC9305548 DOI: 10.1111/prd.12416] [Citation(s) in RCA: 69] [Impact Index Per Article: 34.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Both fixed and removable implant-supported prostheses are well-established methods for replacing missing teeth in partially or fully edentulous patients. Numerous systematic reviews have been performed in recent years to evaluate the survival and complication rates of implant-retained fixed dental prostheses and implant-retained overdentures, displaying high 5-year survival rates ranging from 97.1% for fixed dental prostheses to 95%-100% for implant-retained overdentures. However, the survival rates only represent the prostheses remaining in use for a defined follow-up time, and do not account for the potential prosthetic complications that may have arisen and influence the general success of the implant treatment. The most common technical complications of fixed implant-retained single crowns are crown fracture, fractures of ceramic implant abutments, and esthetic problems. The predominant technical complication at multiple-unit, implant-retained fixed dental prostheses is fracture/chipping of the veneering ceramic. Reported technical complications for implant-retained overdentures are overdenture fracture or chipping of the veneer materials, whereas mechanical complications include implant fracture, attachment failure, and attachment housing or insert complications. To reduce the risk of such failures, a comprehensive pretreatment diagnostic work-up is essential, including defining the prosthetic goal with the aid of a wax-up or set-up and the associated ideal, prosthetically oriented three-dimensional implant position. Furthermore, selection of the ideal type of prosthesis, including the respective implant components and materials, is important for clinical long-term treatment success.
Collapse
Affiliation(s)
- Irena Sailer
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
| | - Duygu Karasan
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
| | - Ana Todorovic
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
- Division of ProsthodonticsFaculty of Dental MedicineUniversity of BelgradeBelgradeSerbia
| | - Maria Ligoutsikou
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
| | - Bjarni Elvar Pjetursson
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
- Department of Reconstructive DentistryFaculty of OdontologyUniversity of IcelandReykjavikIceland
| |
Collapse
|
19
|
Evaluation of the Behavior of Two CAD/CAM Fiber-Reinforced Composite Dental Materials by Immersion Tests. MATERIALS 2021; 14:ma14237185. [PMID: 34885342 PMCID: PMC8658643 DOI: 10.3390/ma14237185] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 11/20/2021] [Accepted: 11/22/2021] [Indexed: 01/15/2023]
Abstract
Fiber-reinforced composites are used as restorative materials for prosthetic oral rehabilitation. Gastroesophageal reflux disease (GERD) is an accustomed affection with various oral manifestations. This study aimed to evaluate the behavior of two high-performance CAD/CAM milled reinforced composites (Trinia™, TriLor) in artificial saliva at different pH levels through immersion tests, and to determine if changes in mass or surface morphology at variable pH, specific for patients affected by GERD, appear. After investigating the elemental composition and surface morphology, the specimens were immersed in Carter Brugirard artificial saliva for 21 days at different pH values (5.7, 7.6, and varying the pH from 5.7 to 3). The values of the weighed masses during the immersion tests were statistically processed in terms of mean and standard deviation. Results suggested that irrespective of the medium pH, the two composites presented a similar mass variation in the range of −0.18 (±0.01)–1.82 (±0.02) mg after immersion, suggesting their stability when in contact with artificial saliva, an aspect which was also highlighted by scanning electron microscope (SEM) analysis performed on the immersed surfaces. Novel composite biomaterials can be a proper alternative for metal alloys used for prosthetic frameworks in patients suffering from GERD.
Collapse
|
20
|
Goriuc A, Jităreanu A, Mârțu I, Dascălu CG, Kappenberg-Niţescu DC, Solomon SM, Mârțu A, Foia L, Țapu I, Istrate B, Tatarciuc M, Luchian I. Experimental EDX analysis of different periodontal splinting systems. Exp Ther Med 2021; 22:1384. [PMID: 34650632 PMCID: PMC8506950 DOI: 10.3892/etm.2021.10820] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 08/16/2021] [Indexed: 01/23/2023] Open
Abstract
Physiological/normal tooth mobility may be defined as the slight displacement of the clinical crown of a tooth, which is allowed by the resilience of an intact and healthy periodontium, under the application of a moderate force. The factors influencing the success and longevity of dental splinting are the type of material used for the splint, the type of composite resin, the number and location of the dental units included for splinting (maxillary or mandibular arch). In periodontology, the term 'splint' is defined as the joining of two or more teeth into a rigid unit through restorations or fixed or removable devices. The purpose of using periodontal splints for tooth immobilization is to provide a period of rest in the areas where the healing process has begun and to allow normal functioning there where the tissues alone would not be able to withstand occlusal forces. The aim of the present study was to evaluate comparatively, by means of energy dispersive electron spectrometry (EDX), the chemical composition in the case of in vitro samples that structurally reproduce direct periodontal immobilization systems using fiberglass strips and fluid composite resins. The differences in the chemical composition of the investigated materials can influence their physiochemical properties, but also their biological and toxicological reliability. Elements such as C, O, Al, Si and Ba were identified as common elements among the resins tested in the present study. The only difference in terms of the component elements was found in the case of the fluid composite Clearfil Majesty ES Flow, which, apart from the elements mentioned, also presented Co in its structure.
Collapse
Affiliation(s)
- Ancuța Goriuc
- Department of Biochemistry, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Alexandra Jităreanu
- Department of Toxicology, Faculty of Pharmacy, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Ioana Mârțu
- Department of Dental Technology, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Cristina Gena Dascălu
- Department of Medical Informatics and Biostatistics, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Diana Cristala Kappenberg-Niţescu
- Department of Periodontology, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Sorina-Mihaela Solomon
- Department of Periodontology, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Alexandra Mârțu
- Department of Periodontology, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Liliana Foia
- Department of Biochemistry, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Iustin Țapu
- Department of Periodontology, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Bogdan Istrate
- Department of Mechanical Engineering, Mechatronics and Robotics, Faculty of Mechanical Engineering, 'Gheorghe Asachi' Technical University of Iasi, 700050 Iasi, Romania
| | - Monica Tatarciuc
- Department of Dental Technology, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| | - Ionuț Luchian
- Department of Periodontology, Faculty of Dental Medicine, 'Grigore T. Popa' University of Medicine and Pharmacy, 700115 Iasi, Romania
| |
Collapse
|
21
|
Behl S, Rajan G, Raju, Farrar P, Prentice L, Prusty BG. Evaluation of depth-wise post-gel polymerisation shrinkage behaviour of flowable dental composites. J Mech Behav Biomed Mater 2021; 124:104860. [PMID: 34628187 DOI: 10.1016/j.jmbbm.2021.104860] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Revised: 09/23/2021] [Accepted: 09/24/2021] [Indexed: 11/24/2022]
Abstract
Short fibre reinforced flowable dental composites are gaining acceptance over particulate filled composites due to their competence to impart improved physio-mechanical properties and capability to prevent crack propagation. However, limited research exists to assess their overall post-gel shrinkage behaviour, which is an important factor to determine marginal seal around restoration and hence its longevity. In this paper, depth-wise post-gel shrinkage strain and the resulting factors such as degree of conversion and rheological behaviour of flowable fibre reinforced composite (FRC) containing 5% weight fraction of 5 μm diameter, 350 μm length S-Glass fibres in UDMA/TEGDMA mixture along with 50% strontium filler particles were investigated. Post-gel shrinkage strain was measured using an array of optical fibre Bragg grating sensors (FBGs) of diameter 250 μm and length 1 mm each embedded at three different depths (depth 0 mm, depth 2.5 mm and depth 5 mm from curing light tip) within the flowable dental composite samples. The rheological behaviour during the polymerisation process was carried out using dynamic oscillatory tests. To evaluate the conversion of CC during polymerisation, degree of conversion tests were conducted by using FTIR spectroscopy. The results obtained for FRC samples were further compared with that of particulate filled composite (PFC) samples, with 55% strontium filler particles only within the same resin system. The relationship between post-gel shrinkage strain at different depths, rheological behaviour and degree of conversion was also explored. The experimental results from the sensor embedded materials suggested that the post-gel shrinkage strain was higher at the top surface (depth 0 mm) and was 50% more than at the bottom surface (depth of 5 mm) for dental FRC as well as PFC samples. Further, similar flow behaviour and not significant different (p<0.05) degree of conversion (DC), post-gel shrinkage strain for dental PFC and FRC composites was observed, establishing a convincing positive relationship between all the key factors and further implying that replacement of fibres with fillers did not affect the overall post-gel polymerisation shrinkage behaviour in dental composites. This investigation has also demonstrated that fibre optic sensors-based shrinkage measurements can be an ideal technique to evaluate post-gel shrinkage performance of dental resins with PFCs or FRCs.
Collapse
Affiliation(s)
- Sonam Behl
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia.
| | - Ginu Rajan
- School of Technologies, Cardiff Metropolitan University, Cardiff, CF5 2YB, UK; ARC Centre for Automated Manufacture of Advanced Composites, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Raju
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Paul Farrar
- SDI Limited, Melbourne, VIC, 3153, Australia
| | | | - B Gangadhara Prusty
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia; ARC Centre for Automated Manufacture of Advanced Composites, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| |
Collapse
|
22
|
Aldhuwayhi S, Shaikh SA, Thakare AA, Mustafa MZ, Mallineni SK. Remote Management of Prosthodontic Emergencies in the Geriatric Population During the Pandemic Outbreak of COVID-19. Front Med (Lausanne) 2021; 8:648675. [PMID: 34395459 PMCID: PMC8355538 DOI: 10.3389/fmed.2021.648675] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 05/31/2021] [Indexed: 12/23/2022] Open
Abstract
The global pandemic outbreak of coronavirus disease 2019 (COVID-19) has put the world in a panic situation. It has been evident that the geriatric population is more susceptible to acquire this infection. Thus, due to this ongoing crisis, geriatric individuals cannot visit a dental operatory, and there is the possibility of their dental needs and emergencies to remain unattended. Partial or complete edentulism is very prevalent among the geriatric population, and prosthodontic management of these patients is essential for their well-being. However, the prosthesis can lead to various emergencies of the oral and its supporting structures. There are currently no available recommendations to address these prosthodontic emergencies in geriatric individuals during this pandemic period. Hence, the aims of this minireview were to discuss the common prosthodontic emergencies in the geriatric population and provide recommendations to manage these issues during the COVID-19 pandemic outbreak.
Collapse
Affiliation(s)
- Sami Aldhuwayhi
- Department of Prosthodontics, College of Dentistry, Majmaah University, Al-Majmaah, Saudi Arabia
| | - Saquib Ahmed Shaikh
- Department of Prosthodontics, College of Dentistry, Majmaah University, Al-Majmaah, Saudi Arabia
| | - Amar Ashok Thakare
- Department of Prosthodontics, College of Dentistry, Majmaah University, Al-Majmaah, Saudi Arabia
| | | | - Sreekanth Kumar Mallineni
- Department of Preventive Dental Science, College of Dentistry, Majmaah University, Al-Majmaah, Saudi Arabia.,Department of Pediatric and Preventive Dentistry, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Science, Saveetha University, Chennai, India
| |
Collapse
|
23
|
Characterization of Experimental Short-Fiber-Reinforced Dual-Cure Core Build-Up Resin Composites. Polymers (Basel) 2021; 13:polym13142281. [PMID: 34301038 PMCID: PMC8309262 DOI: 10.3390/polym13142281] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/07/2021] [Accepted: 07/08/2021] [Indexed: 12/28/2022] Open
Abstract
As a core build-up material, dual-cured (DC) resin-based composites are becoming popular. The aim of this research was to investigate specific physical and handling properties of new experimental short-fiber-reinforced DC resin composites (SFRCs) in comparison to different commercial, conventional DC materials (e.g., Gradia Core, Rebilda DC, LuxaCore Z, and Visalys® CemCore). Degree of monomer conversion (DC%) was determined by FTIR-spectrometry using either self- or light-curing mode. The flexural strength, modulus, and fracture toughness were calculated through a three-point bending setup. Viscosity was analyzed at room (22 °C) and mouth (35 °C) temperatures with a rotating disk rheometer. The surface microstructure of each resin composite was examined with scanning electron microscopy (SEM). Data were statistically analyzed with analysis of variance ANOVA (p = 0.05). The curing mode showed significant (p < 0.05) effect on the DC% and flexural properties of tested DC resin composites and differences were material dependent. SFRC exhibited the highest fracture toughness (2.3 MPa m1/2) values and LuxaCore showed the lowest values (1 MPa m1/2) among the tested materials (p < 0.05). After light curing, Gradia Core and SFRCs showed the highest flexural properties (p < 0.05), while the other resin composites had comparable values. The novel DC short-fiber-reinforced core build-up resin composite demonstrated super fracture toughness compared to the tested DC conventional resin composites.
Collapse
|
24
|
Someya T, Kasahara M, Takemoto S, Hattori M. Retention force of fiber-reinforced composite resin post on resin composite for core buildup -Effects of fiber orientation, silane treatment and thermal cycling. Dent Mater J 2021; 40:1264-1269. [PMID: 34193726 DOI: 10.4012/dmj.2020-416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to investigate the effects of fiber orientation, silane treatment, and thermal cycling on the retention force of fiber-reinforced composite resin (FRC) posts on resin composite. Two types of FRC posts (linear and woven) were prepared with and without silane treatment. Pull-out test specimens were made of FRC posts and resin composite for core buildup. Specimens were either incubated in distilled water for 24 h or subjected to 10,000 thermal cycles. The maximum fracture load obtained by a pull-out test was defined as the retention force. Fracture modes were observed after the test. Fiber orientation and thermal cycling did not affect the retention force on resin composite, and the retention force was improved by silane treatment. Whereas, fiber orientation affected the fracture mode. The result showed woven fiber orientation could contribute to the mechanically interlocking with the resin composite.
Collapse
Affiliation(s)
- Tomoko Someya
- Department of Dental Materials Science, Tokyo Dental College
| | | | - Shinji Takemoto
- Department of Biomedical Engineering, Iwate Medical University
| | | |
Collapse
|
25
|
Gibreel M, Sameh A, Hegazy S, Närhi TO, Vallittu PK, Perea-Lowery L. Effect of specific retention biomaterials for ball attachment on the biomechanical response of single implant-supported overdenture: A finite element analysis. J Mech Behav Biomed Mater 2021; 122:104653. [PMID: 34229172 DOI: 10.1016/j.jmbbm.2021.104653] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 05/03/2021] [Accepted: 06/16/2021] [Indexed: 12/13/2022]
Abstract
PURPOSE The purpose of this finite element analysis (FEA) was to evaluate the effect of specific retention biomaterials with different elastic modulus on the biomechanical response to the axial and off-axial biting loads of a mandibular midline single implant-supported overdenture (SIO) model. METHODS Five 3-dimensional (3D) finite element models of an edentulous mandible with SIO were designed as follows: model M with a titanium retentive element for ball attachment, model P with a PEEK retentive element, model S with a silicone resilient liner retentive element, model T with a thermoplastic acrylic resin retentive element made from a CAD-CAM material, and model A with a polyacetal resin retentive element. Posterior bilateral vertical load (PV) at the 1st molar areas and anterior oblique load (AO) at the incisal edge of the mandibular central incisors at a 30-degree angle of 100 N were applied. Stress values were recorded. RESULTS Stress values were higher for all models under (AO) loading than under (PV) loading. Model M recorded the highest stress values on the implant, its components, cortical, and cancellous bone under both loading conditions. Under (AO) loading condition, the ball abutment von Mises stress value in model S was almost 7 times lower than that of model M (19 and 130 MPa respectively) and the other 3 models (P, T, and A) (119, 121, and 120 MPa respectively). However, model S recorded the highest value of denture base stress at the attachment area. CONCLUSIONS The elastic modulus of retention materials can affect stresses generated on the implant overdenture components and supporting structures.
Collapse
Affiliation(s)
- Mona Gibreel
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
| | - Ahmed Sameh
- Production Engineering Dept., Faculty of Engineering, Mansoura University, Mansoura, Egypt
| | - Salah Hegazy
- Professor and Chair of Department of Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt
| | - Timo O Närhi
- Department of Prosthetic Dentistry, and Stomatognathic Physiology, University of Turku, Turku, Finland; and City of Turku, Welfare Division, Turku, Finland
| | - Pekka K Vallittu
- Professor, and Chair of Biomaterials Science Department, University of Turku, Turku, Finland; and City of Turku, Welfare Division, Turku, Finland
| | - Leila Perea-Lowery
- Department of Biomaterials Science, Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| |
Collapse
|
26
|
Framework Materials for Full-Arch Implant-Supported Rehabilitations: A Systematic Review of Clinical Studies. MATERIALS 2021; 14:ma14123251. [PMID: 34204681 PMCID: PMC8231547 DOI: 10.3390/ma14123251] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/03/2021] [Accepted: 06/08/2021] [Indexed: 12/24/2022]
Abstract
The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch prostheses. A literature search was conducted on MEDLINE, Scopus and Cochrane Library, until the 1st of March 2021, with the following search terms: framework or substructure combined with "dental implants". The outcomes evaluated were: implant and prosthesis survival, bone resorption, biological and technical complications. The Cochrane Handbook for Systematic Reviews of Interventions was employed to assess the risk of bias in randomized clinical trials. The Newcastle-Ottawa quality assessment scale was used for non-randomized studies. In total, 924 records were evaluated for title and abstract, and 11 studies were included in the review: 4 clinical randomized trials and 7 cohort studies. The framework materials investigated were: gold alloy, titanium, silver-palladium alloy, zirconia and polymers including acrylic resin and carbon-fiber-reinforced composites. High implant and prosthetic cumulative survival rates were recorded by all included studies. Various materials and different fabrication techniques are now available as alternatives to traditional cast metal frameworks, for full-arch implant-supported rehabilitations. Further long-term studies are needed to validate the use of these materials and clarify their specific clinical indications and manufacturing protocols to optimize their clinical outcomes.
Collapse
|
27
|
Semisch-Dieter OK, Choi AH, Ben-Nissan B, Stewart MP. Modifying an Implant: A Mini-review of Dental Implant Biomaterials. BIO INTEGRATION 2021. [DOI: 10.15212/bioi-2020-0034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Dental implants have been used as far back as 2000BC, and since then have developed into highly sophisticated solutions for tooth replacement. It is becoming increasingly important for the materials used in dental implants to exhibit and maintain favorable long-term mechanical, biological
and more recently, aesthetic properties. This review aims to assess the biomaterials used in modern dental implants, introducing their properties, and concentrating on modifications to improve these biomaterials. Focus is drawn to the prominent biomaterials, titanium (Ti) and zirconia due
to their prevalence in implant dentistry. Additionally, novel coatings and materials with potential use as viable improvements or alternatives are reviewed. An effective dental biomaterial should osseointegrate, maintain structural integrity, resist corrosion and infection, and not cause systemic
toxicity or cytotoxicity. Current materials such as bioactive glass offer protection against biofilm formation, and when combined with a titanium‐zirconium (TiZr) alloy, provide a reliable combination of properties to represent a competitive alternative. Further long-term clinical studies
are needed to inform the development of next-generation materials.Significance StatementBiomaterials have become essential for modern implants. A suitable implant biomaterial integrates into the body to perform a key function, whilst minimizing negative immune response. Focusing
on dentistry, the use of dental implants for tooth replacement requires a balance between bodily response, mechanical structure and performance, and aesthetics. This mini-review addresses the use of biomaterials in dental implants with significant comparisons drawn between Ti and zirconia.
Attention is drawn to optimizing surface modification processes and the additional use of coatings. Alternatives and novel developments are addressed, providing potential implications of combining biomaterials to form novel composites that combine and synergize the benefits of each material.
Collapse
Affiliation(s)
- Oliver K. Semisch-Dieter
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Andy H. Choi
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Besim Ben-Nissan
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| | - Martin P. Stewart
- School of Life Sciences, Faculty of Science, University of Technology Sydney, Ultimo, NSW, Australia
| |
Collapse
|
28
|
Huang Y, Song B, Zhou X, Chen H, Wang H, Cheng L. Dental Restorative Materials for Elderly Populations. Polymers (Basel) 2021; 13:polym13050828. [PMID: 33800358 PMCID: PMC7962827 DOI: 10.3390/polym13050828] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 03/02/2021] [Accepted: 03/04/2021] [Indexed: 01/26/2023] Open
Abstract
The incidence of dental caries, especially root caries, has risen in elderly populations in recent years. Specialized restorative materials are needed due to the specific site of root caries and the age-related changes in general and oral health in the elderly. Unfortunately, the restorative materials commonly used clinically cannot fully meet the requirements in this population. Specifically, the antibacterial, adhesive, remineralization, mechanical, and anti-aging properties of the materials need to be significantly improved for dental caries in the elderly. This review mainly discusses the strengths and weaknesses of currently available materials, including amalgam, glass ionomer cement, and light-cured composite resin, for root caries. It also reviews the studies on novel anti-caries materials divided into three groups, antimicrobial, remineralization, and self-healing materials, and explores their potential in the clinical use for caries in the elderly. Therefore, specific restorative materials for caries in the elderly, especially for root caries, need to be further developed and applied in clinical practice.
Collapse
Affiliation(s)
- Yuyao Huang
- State Key Laboratory of Oral Diseases, West China School of Stomatology, National Clinical Research Center for Oral Diseases, Sichuan University, Chengdu 610064, China; (Y.H.); (B.S.); (X.Z.)
- Department of Cariology and Endodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Bingqing Song
- State Key Laboratory of Oral Diseases, West China School of Stomatology, National Clinical Research Center for Oral Diseases, Sichuan University, Chengdu 610064, China; (Y.H.); (B.S.); (X.Z.)
- Department of Cariology and Endodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Xuedong Zhou
- State Key Laboratory of Oral Diseases, West China School of Stomatology, National Clinical Research Center for Oral Diseases, Sichuan University, Chengdu 610064, China; (Y.H.); (B.S.); (X.Z.)
- Department of Cariology and Endodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Hui Chen
- Department of Operative Dentistry and Endodontics, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou 510055, China;
| | - Haohao Wang
- State Key Laboratory of Oral Diseases, West China School of Stomatology, National Clinical Research Center for Oral Diseases, Sichuan University, Chengdu 610064, China; (Y.H.); (B.S.); (X.Z.)
- Department of Cariology and Endodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China
- Correspondence: (H.W.); (L.C.)
| | - Lei Cheng
- State Key Laboratory of Oral Diseases, West China School of Stomatology, National Clinical Research Center for Oral Diseases, Sichuan University, Chengdu 610064, China; (Y.H.); (B.S.); (X.Z.)
- Department of Cariology and Endodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China
- Correspondence: (H.W.); (L.C.)
| |
Collapse
|
29
|
Raju R, Rajan G, Farrar P, Prusty BG. Dimensional stability of short fibre reinforced flowable dental composites. Sci Rep 2021; 11:4697. [PMID: 33633198 PMCID: PMC7907147 DOI: 10.1038/s41598-021-83947-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Accepted: 02/08/2021] [Indexed: 11/24/2022] Open
Abstract
Fibre-reinforced dental composites are proven to have superior mechanical properties in comparison with micro/nano/hybrid filled composites. However, the addition of small quantities of short glass fibres could affect the dimensional stability of the restoration both during initial stages as well as through the life of the restoration. This in-vitro study aims at evaluating the physical properties of short S-Glass reinforced flowable dental composites. Two S-Glass short fibre-particulate reinforced (5 wt% of aspect ratios 50 and 70) and one particulate only reinforced flowable dental composites were prepared with UDMA-TEGDMA based dental monomer systems. Samples were photopolymersied for 60 s and stored in distilled water at 37 °C for 24 h before testing. Depth of cure (through-thickness microhardness), volumetric shrinkage (Archimedes technique), polymerisation stress (cantilever based tensometer), curing exotherm (thermocouple), water sorption and solubility (ISO 4049) and thermal expansion coefficient (dilatometer) were determined. The test results were statistically analysed using one-way ANOVA (p < 0.05). Depth of cure increased by 41%, volumetric shrinkage increased by 8.3%, shrinkage stress increased by 37.6%, exotherm increased by 20.2%, and thermal expansion reduced by 6.4% while water sorption and solubility had a negligible effect with the inclusion of short glass fibres. The study demonstrates that within the same organic resin system and quantity, a small replacement of fillers with short fibres could significantly affect the dimensional stability of the composite system. In conjunction with mechanical properties, this study could help clinicians to gain confidence in fibre reinforced dental composite restorative system.
Collapse
Affiliation(s)
- Raju Raju
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Ginu Rajan
- School of Electrical, Computer & Telecommunications Engineering, University of Wollongong, Wollongong, NSW, 2522, Australia. .,ARC Centre for Automated Manufacture of Advanced Composites, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia.
| | - Paul Farrar
- SDI Limited, Melbourne, VIC, 3153, Australia
| | - B Gangadhara Prusty
- ARC Centre for Automated Manufacture of Advanced Composites, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| |
Collapse
|
30
|
Elsubeihi ES, Aljafarawi T, Elsubeihi HE. State of the Art Contemporary Prefabricated Fiber-Reinforced Posts. Open Dent J 2020. [DOI: 10.2174/1874210602014010313] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Background:
There is an increased interest in investigating and use of prefabricated fiber-reinforced posts by scientists and clinicians in the restoration of endodontically treated teeth.
Objective:
The objective of this narrative review was to summarize the composition of contemporary prefabricated fiber-reinforced posts and elucidate its effect on the different properties of these posts.
Methods:
PubMed/Medline, Scopus, and Google Scholar were searched from January 1990 to December 2019 for English Language articles describing the composition and properties of prefabricated fiber-reinforced posts. First, the search strategy was established for Medline / PubMed using the following terms ((Fiber post[All Fields] OR (fiber reinforced post[All Fields] AND composition[All Fields] AND (“matrix”[MeSH Terms] OR (“fiber”[All Fields] AND “properties”[All Fields] AND “epoxy”[All Fields]) OR “dimethacrylate”[All Fields]) AND NOT (CAD CAM[All Fields])). The search strategy was then adapted for Scopus and Google Scholar databases to identify eligible studies.
Results:
The current state of the art of prefabricated fiber-reinforced posts revealed a myriad of products with different formulations which are reflected on the mechanical and handling characteristics of the different posts available in the market. More recent research and development efforts attempted to address issues related to the improved transmission of polymerization light through the post to the most apical end of the restoration inside the root canal. Others focused on the development of new matrix materials for fiber-reinforced posts.
Conclusion:
A review of the literature revealed that currently available prefabricated fiber-reinforced posts consist of a heterogeneous group of materials which can have a significant effect on the behavior of posts. Understanding different formulations will help clinicians in scrutinizing the vast literature available on prefabricated fiber-reinforced posts. This, in turn, will help them make an informed decision when selecting materials for the restoration of endodontically treated teeth.
Collapse
|
31
|
Gibreel M, Lassila LV, Närhi TO, Perea-Lowery L, Vallittu PK. Fatigue resistance of a simulated single LOCATOR overdenture system. J Prosthet Dent 2019; 122:557-563. [DOI: 10.1016/j.prosdent.2018.11.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 11/08/2018] [Accepted: 11/08/2018] [Indexed: 02/06/2023]
|
32
|
Gibreel MF, Khalifa A, Said MM, Mahanna F, El-Amier N, Närhi TO, Perea-Lowery L, Vallittu PK. Biomechanical aspects of reinforced implant overdentures: A systematic review. J Mech Behav Biomed Mater 2018; 91:202-211. [PMID: 30594062 DOI: 10.1016/j.jmbbm.2018.12.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 12/07/2018] [Accepted: 12/08/2018] [Indexed: 12/17/2022]
Abstract
PURPOSE The purpose of this systematic review was to investigate the effect of reinforcement on the mechanical behaviour of implant overdenture (IOD) bases and its cumulative biological effect on the underlying supporting structures (implants and the residual ridge). MATERIAL AND METHODS The required documents were collected electronically from PubMed and Web of Science databases targeting papers published in English that focused on denture base reinforcement for IOD prostheses in order to recognize the principal outcomes of reinforcement on the mechanical and biological properties of overdentures. Such biological outcomes as: strains on implants, peri-implant bone loss, residual ridge resorption, and strain on the residual alveolar ridge. RESULTS A total of 269 citations were identified. After excluding any repeated articles between databases and the application of exclusion and inclusion criteria, only 13 publications fulfilled the inclusion criteria. Three publications investigated the mechanical properties of fibre and/or metal-reinforced implant overdentures while another 3 articles investigated the effect of metal reinforcement on stress distribution and strains transmitted to the underlying implants. In addition, 3 in vitro studies investigated the effect of metal reinforcement on overdenture base strain and stresses. Stress distribution to the residual ridge and strain characteristics of the underlying tissues were investigated by 2 in vitro studies. Five clinical studies performed to assist the clinical and prosthetic maintenance of metal-reinforced IOD were included. Data concerning denture base fracture, relining, peri-implant bone loss, probing depth, and implant survival rates during the functional period were extracted and considered in order to evaluate the mechanical properties of the denture base, residual ridge resorption and implant preservation rates, respectively. CONCLUSION The use of a denture base reinforcement can reduce the fracture incidence in IOD bases by enhancing their flexural properties and reducing the overdenture base deformation. Strains on the underlying supporting structures of overdenture prostheses including dental implants and the residual ridge can be decreased and evenly distributed using a metal reinforcement.
Collapse
Affiliation(s)
- Mona Fathy Gibreel
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
| | - Ahmed Khalifa
- Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt
| | - Mohamed Moustafa Said
- Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt
| | - Fatma Mahanna
- Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt
| | - Nesma El-Amier
- Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Egypt
| | - Timo O Närhi
- Department of Prosthetic Dentistry and Stomatognathic Physiology, University of Turku, Turku, Finland; Department of Oral Diseases, Turku University Hospital, Turku, Finland
| | - Leila Perea-Lowery
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Pekka K Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre-TCBC, Institute of Dentistry, University of Turku, Turku, Finland; Welfare Division, City of Turku, Turku, Finland
| |
Collapse
|
33
|
Lempel E, Őri Z, Szalma J, Lovász BV, Kiss A, Tóth Á, Kunsági-Máté S. Effect of exposure time and pre-heating on the conversion degree of conventional, bulk-fill, fiber reinforced and polyacid-modified resin composites. Dent Mater 2018; 35:217-228. [PMID: 30503020 DOI: 10.1016/j.dental.2018.11.017] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Revised: 10/03/2018] [Accepted: 11/14/2018] [Indexed: 01/16/2023]
Abstract
OBJECTIVE To determine the degree of conversion (DC) of different type of resin-based composites (RBC) in eight-millimeter-deep clinically relevant molds, and investigate the influence of exposure time and pre-heating on DC. METHODS Two-millimeter-thick samples of conventional sculptable [FiltekZ250 (FZ)], flowable [Filtek Ultimate Flow (FUF)] and polyacid-modified [Twinky Star Flow (TS)] RBCs, and four-millimeter-thick samples of flowable bulk-fill [Filtek Bulk Fill Flow (FBF), Surefil SDR (SDR)] and sculptable fibre-reinforced [EverX Posterior (EX)] RBCs were prepared in an eight-millimeter-deep mold. The RBCs temperature was pre-set to 25, 35 and 55°C. The RBCs were photopolymerized with the recommended and its double exposure time. The DC at the top and bottom was measured with micro-Raman spectroscopy. Data were analyzed with ANOVA and Scheffe post-hoc test (p<0.05). RESULTS The differences in DC% between the top/bottom and the recommended/extended exposure time were significant for the materials, except SDR (64.5/63.0% and 67.4/63.0%). FUF (69.0% and 53.4%) and TS (64.9% and 60.9%) in 2mm provided higher DC% at the top and bottom with the recommended curing time, compared to the other materials, except SDR. Pre-heating had negative effect on DC at the bottom in flowable RBCs (FUF: 48.9%, FBF: 36.7%, SDR: 43%, TS: 54.7%). Pre-heating to 55 °C significantly increased the DC% in fibre-reinforced RBC (75.0% at the top, 64.7% at the bottom). SIGNIFICANCE Increased exposure time improves the DC for each material. Among bulk-fills, only SDR performed similarly, compared to the two-millimeter-thick flowable RBCs. Pre-heating of low-viscosity RBCs decreased the DC% at the bottom. Pre-heating of fibre-reinforced RBC to 55°C increased the DC% at a higher rate than the extended curing time.
Collapse
Affiliation(s)
- Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary.
| | - Zsuzsanna Őri
- Department of General and Physical Chemistry, University of Pécs, 6 Ifjúság Street, Pécs, H-7624, Hungary; János Szentágothai Research Center, 20 Ifjúság Street, Pécs, H-7624, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs, Pécs, Hungary
| | - Bálint Viktor Lovász
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary
| | - Adél Kiss
- Department of Restorative Dentistry and Periodontology, University of Pécs, Pécs, Hungary
| | - Ákos Tóth
- Faculty of Sciences, University of Pécs Pécs, Hungary
| | - Sándor Kunsági-Máté
- Department of General and Physical Chemistry, University of Pécs, 6 Ifjúság Street, Pécs, H-7624, Hungary; János Szentágothai Research Center, 20 Ifjúság Street, Pécs, H-7624, Hungary
| |
Collapse
|