1
|
Tukimin SN, Karman SB, Wan Kamarul Zaman WS, Mohd Yunos NB, Syed Nor SN, Ahmad MY. The angle of polarized light (AOP) property for optical classification of the crosslinked polymer. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 330:125503. [PMID: 39842129 DOI: 10.1016/j.saa.2024.125503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 10/12/2024] [Accepted: 11/25/2024] [Indexed: 01/24/2025]
Abstract
Light-matter interaction has been profoundly studied for sample material classification. However, the optical classification of the sample through the polarized light-matter interaction remains underexplored. It is limited to the measurement of intensity instead of the angle of polarized light (AOP) for its degree of polarization. Measurement of the degree of polarization within a material or a medium becomes easier with a simple, low-cost and direct measurement without the need of any probing or labelling agent. Thus, this investigation was conducted mainly to determine the angle of polarized light (AOP) property of the crosslinked polymer using our proposed polarization measurement technique as an alternative approach of the material classification. The angle of polarized light (AOP) of each polymer was determined in combination property of polarization by absorption, transmission, and scattering. Our proposed scattered angle (ס=90°, 100°, 110°, and 120°) successfully measured the AOP of each polymer that can be classified into two groups. Group 1 represents the AOP value ( [Formula: see text] ) for a test sample of t1 = 3.1 %, 3.2, and 3.3 % with comparison to the normal sample (n = 3.0 %) and Group 2 represents the AOP value ( [Formula: see text] ) for the test sample oft2 = 3.4 %, 3.6 % and 3.7 % with comparison to the normal sample (n = 3.0 %). Our study proved a direct, easy, and simple method of determining the degree of polarization of the polymers without the need of complex formulation and labelling protocol. Therefore, this work may enhance the investigation of the optical properties of the agarose-based tissue-mimicking phantom (AGTMP) for modeling or simulation of the real biological sample in the future. Our polarization measures are worthy of further explored and implemented in current optical imaging techniques or sensing platform for optical classification of the biomaterials.
Collapse
Affiliation(s)
- Siti Nurainie Tukimin
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Federal Territory of Kuala Lumpur, Kuala Lumpur 50603 Malaysia.
| | - Salmah Binti Karman
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Federal Territory of Kuala Lumpur, Kuala Lumpur 50603 Malaysia.
| | - Wan Safwani Wan Kamarul Zaman
- Department of Pharmaceutical Life Sciences, Faculty of Pharmacy, Universiti Malaya, Federal Territory of Kuala Lumpur, Kuala Lumpur 50603 Malaysia
| | - Nuranisha Binti Mohd Yunos
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Federal Territory of Kuala Lumpur, Kuala Lumpur 50603 Malaysia
| | - Sharifah Norsyahindah Syed Nor
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Federal Territory of Kuala Lumpur, Kuala Lumpur 50603 Malaysia
| | - Mohd Yazed Ahmad
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Federal Territory of Kuala Lumpur, Kuala Lumpur 50603 Malaysia
| |
Collapse
|
2
|
Chimene D, Queener KMK, Ko BS, McShane M, Daniele M. Insertable Biosensors: Combining Implanted Sensing Materials with Wearable Monitors. Annu Rev Biomed Eng 2024; 26:197-221. [PMID: 38346276 DOI: 10.1146/annurev-bioeng-110222-101045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/05/2024]
Abstract
Insertable biosensor systems are medical diagnostic devices with two primary components: an implantable biosensor within the body and a wearable monitor that can remotely interrogate the biosensor from outside the body. Because the biosensor does not require a physical connection to the electronic monitor, insertable biosensor systems promise improved patient comfort, reduced inflammation and infection risk, and extended operational lifetimes relative to established percutaneous biosensor systems. However, the lack of physical connection also presents technical challenges that have necessitated new innovations in developing sensing chemistries, transduction methods, and communication modalities. In this review, we discuss the key developments that have made insertables a promising option for longitudinal biometric monitoring and highlight the essential needs and existing development challenges to realizing the next generation of insertables for extended-use diagnostic and prognostic devices.
Collapse
Affiliation(s)
- David Chimene
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA;
| | - Kirstie M K Queener
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, North Carolina, USA
| | - Brian S Ko
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA;
| | - Mike McShane
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA;
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas, USA
| | - Michael Daniele
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, North Carolina, USA
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, North Carolina, USA;
| |
Collapse
|
3
|
Tchvialeva L, Phillips J, Louie DC, Zeng H, Lui H, Lee TK. Micro-relief characterization of benign and malignant skin lesions by polarization speckle analysis in vivo. PHOTODERMATOLOGY, PHOTOIMMUNOLOGY & PHOTOMEDICINE 2023; 39:449-456. [PMID: 37138413 DOI: 10.1111/phpp.12876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 04/05/2023] [Accepted: 04/13/2023] [Indexed: 05/05/2023]
Abstract
BACKGROUND/PURPOSE A recent direction in skin disease classification is to develop quantitative diagnostic techniques. Skin relief, colloquially known as roughness, is an important clinical feature. The aim of this study is to demonstrate a novel polarization speckle technique to quantitatively measure roughness on skin lesions in vivo. We then calculate the average roughness of different types of skin lesions to determine the extent to which polarization speckle roughness measurements can be used to identify skin cancer. METHODS The experimental conditions were set to target the fine relief structure on the order of ten microns within a small field of view of 3 mm. The device was tested in a clinical study on patients with malignant and benign skin lesions that resemble cancer. The cancer group includes 37 malignant melanomas (MM), 43 basal cell carcinomas (BCC), and 26 squamous cell carcinomas (SCC), all categories confirmed by gold standard biopsy. The benign group includes 109 seborrheic keratoses (SK), 79 nevi, and 11 actinic keratoses (AK). Normal skin roughness was obtained for the same patients (301 different body sites proximal to the lesion). RESULTS The average root mean squared (rms) roughness ± standard error of the mean for MM and nevus was equal to 19 ± 5 μm and 21 ± 3 μm, respectively. Normal skin has rms roughness of 31 ± 3 μm, other lesions have roughness of 35 ± 10 μm (AK), 35 ± 7 μm (SCC), 31 ± 4 μm (SK), and 30 ± 5 μm (BCC). CONCLUSION An independent-samples Kruskal-Wallis test indicates that MM and nevus can be separated from each of the tested types of lesions, except each other. These results quantify clinical knowledge of lesion roughness and could be useful for optical cancer detection.
Collapse
Affiliation(s)
- Lioudmila Tchvialeva
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada
- Department of Cancer Control Research, BC Cancer, Vancouver, British Columbia, Canada
| | - Jamie Phillips
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada
- Department of Cancer Control Research, BC Cancer, Vancouver, British Columbia, Canada
| | - Daniel C Louie
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada
- Department of Cancer Control Research, BC Cancer, Vancouver, British Columbia, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| | - Haishan Zeng
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada
- Department of Integrative Oncology, Imaging Unit, BC Cancer, Vancouver, British Columbia, Canada
| | - Harvey Lui
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada
- Department of Integrative Oncology, Imaging Unit, BC Cancer, Vancouver, British Columbia, Canada
| | - Tim K Lee
- Department of Dermatology and Skin Science, University of British Columbia, Vancouver, British Columbia, Canada
- Photomedicine Institute, Vancouver Coastal Health Research Institute, Vancouver, British Columbia, Canada
- Department of Cancer Control Research, BC Cancer, Vancouver, British Columbia, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
4
|
Dinh J, Yamashita A, Kang H, Gioux S, Choi HS. Optical Tissue Phantoms for Quantitative Evaluation of Surgical Imaging Devices. ADVANCED PHOTONICS RESEARCH 2023; 4:2200194. [PMID: 36643020 PMCID: PMC9838008 DOI: 10.1002/adpr.202200194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Optical tissue phantoms (OTPs) have been extensively applied to the evaluation of imaging systems and surgical training. Due to their human tissue-mimicking characteristics, OTPs can provide accurate optical feedback on the performance of image-guided surgical instruments, simulating the biological sizes and shapes of human organs, and preserving similar haptic responses of original tissues. This review summarizes the essential components of OTPs (i.e., matrix, scattering and absorbing agents, and fluorophores) and the various manufacturing methods currently used to create suitable tissue-mimicking phantoms. As photobleaching is a major challenge in OTP fabrication and its feedback accuracy, phantom photostability and how the photobleaching phenomenon can affect their optical properties are discussed. Consequently, the need for novel photostable OTPs for the quantitative evaluation of surgical imaging devices is emphasized.
Collapse
Affiliation(s)
- Jason Dinh
- Gordon Center for Medical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Atsushi Yamashita
- Gordon Center for Medical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Homan Kang
- Gordon Center for Medical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Sylvain Gioux
- Intuitive Surgical Sàrl, 1170 Aubonne, Switzerland
- ICube Laboratory, University of Strasbourg, 67081 Strasbourg, France
| | - Hak Soo Choi
- Gordon Center for Medical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Boston, MA 02114, USA
| |
Collapse
|
5
|
Hacker L, Wabnitz H, Pifferi A, Pfefer TJ, Pogue BW, Bohndiek SE. Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation. Nat Biomed Eng 2022; 6:541-558. [PMID: 35624150 DOI: 10.1038/s41551-022-00890-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 02/07/2022] [Indexed: 01/08/2023]
Abstract
A lack of accepted standards and standardized phantoms suitable for the technical validation of biophotonic instrumentation hinders the reliability and reproducibility of its experimental outputs. In this Perspective, we discuss general criteria for the design of tissue-mimicking biophotonic phantoms, and use these criteria and state-of-the-art developments to critically review the literature on phantom materials and on the fabrication of phantoms. By focusing on representative examples of standardization in diffuse optical imaging and spectroscopy, fluorescence-guided surgery and photoacoustic imaging, we identify unmet needs in the development of phantoms and a set of criteria (leveraging characterization, collaboration, communication and commitment) for the standardization of biophotonic instrumentation.
Collapse
Affiliation(s)
- Lina Hacker
- Department of Physics, University of Cambridge, Cambridge, UK
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK
| | - Heidrun Wabnitz
- Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | | | | | - Brian W Pogue
- Thayer School of Engineering, Dartmouth, Hanover, NH, USA
| | - Sarah E Bohndiek
- Department of Physics, University of Cambridge, Cambridge, UK.
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK.
| |
Collapse
|
6
|
Zhou X, Maloufi S, Louie DC, Zhang N, Liu Q, Lee TK, Tang S. Investigating the depolarization property of skin tissue by degree of polarization uniformity contrast using polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:5073-5088. [PMID: 34513243 PMCID: PMC8407846 DOI: 10.1364/boe.424709] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 05/11/2023]
Abstract
The depolarization property of skin has been found to be important for skin cancer detection. Previous techniques based on light polarization lack the capability of depth differentiation. Polarization-sensitive optical coherence tomography (PS-OCT) has the advantage of both depth-resolved 3D imaging and high sensitivity to polarization. In this study, we investigate the depolarization property of skin tissue using PS-OCT, especially with the degree of polarization uniformity (DOPU) contrast. Well designed skin phantoms with various surface roughness levels and optical properties mimicking skin are imaged by PS-OCT and the DOPU values are quantified. The result shows a correlation between DOPU and surface roughness, where a higher roughness corresponds to a lower DOPU value. An index matching experiment with a water layer confirms the impact of surface condition on light depolarization. Refraction of backscattered photons on the surface boundary is attributed to the broadening of backscattering angle and thus depolarization. To the best of our knowledge, this is the first time the impact of surface roughness on DOPU is reported and its mechanism explained. Furthermore, through preliminary in vivo skin imaging, the capability of DOPU in detecting depolarization in skin is demonstrated. By utilizing the 3D imaging from PS-OCT, DOPU can offer a high-resolution depth differentiation and quantification of depolarization in skin tissue.
Collapse
Affiliation(s)
- Xin Zhou
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
| | - Sina Maloufi
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
| | - Daniel C. Louie
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
- Department of Dermatology and Skin Science, Photomedicine Institute, University of British Columbia, and Vancouver Coastal Health Research Institute, Vancouver, BC, V5Z 4E8, Canada
- Cancer Control Research Program, BC Cancer, Vancouver, BC, V5Z 1L3, Canada
| | - Ning Zhang
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
| | - Qihao Liu
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
| | - Tim K. Lee
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
- Department of Dermatology and Skin Science, Photomedicine Institute, University of British Columbia, and Vancouver Coastal Health Research Institute, Vancouver, BC, V5Z 4E8, Canada
- Cancer Control Research Program, BC Cancer, Vancouver, BC, V5Z 1L3, Canada
| | - Shuo Tang
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC V6 T 1Z4, Canada
| |
Collapse
|
7
|
Louie DC, Tchvialeva L, Kalia S, Lui H, Lee TK. Constructing a portable optical polarimetry probe for in-vivo skin cancer detection. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200359R. [PMID: 33686846 PMCID: PMC7938231 DOI: 10.1117/1.jbo.26.3.035001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 02/12/2021] [Indexed: 05/20/2023]
Abstract
SIGNIFICANCE Management of skin cancer worldwide is often a challenge of scale, in that the number of potential cases presented outweighs the resources available to detect and treat skin cancer. AIM This project aims to develop a polarimetry probe to create an accessible skin cancer detection tool. APPROACH An optical probe was developed to perform bulk tissue Stokes polarimetry, a technique in which a laser of known polarization illuminates a target, and the altered polarization state of the backscattered light is measured. Typically, measuring a polarization state requires four sequential measurements with different orientations of polarization filters; however, this probe contains four spatially separated detectors to take four measurements in one shot. The probe was designed to perform at a lower cost and higher speed than conventional polarimetry methods. The probe uses photodiodes and linear and circular film polarizing filters as detectors, and a low-coherence laser diode as its illumination source. The probe design takes advantage of the statistical uniformity of the polarization speckle field formed at the detection area. RESULTS Tests of each probe component, and the complete system put together, were performed to evaluate error and confirm the probe's performance despite its low-cost components. This probe's potential is demonstrated in a pilot clinical study on 71 skin lesions. The degree of polarization was found to be a factor by which malignant melanoma could be separated from other types of skin lesions.
Collapse
Affiliation(s)
- Daniel C. Louie
- University of British Columbia, School of Biomedical Engineering, Vancouver, Canada
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Vancouver, Canada
- BC Cancer, Departments of Cancer Control Research and Integrative Oncology, Vancouver, Canada
| | - Lioudmila Tchvialeva
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Vancouver, Canada
| | - Sunil Kalia
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Vancouver, Canada
- BC Cancer, Departments of Cancer Control Research and Integrative Oncology, Vancouver, Canada
| | - Harvey Lui
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Vancouver, Canada
- BC Cancer, Departments of Cancer Control Research and Integrative Oncology, Vancouver, Canada
| | - Tim K. Lee
- University of British Columbia, School of Biomedical Engineering, Vancouver, Canada
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Vancouver, Canada
- BC Cancer, Departments of Cancer Control Research and Integrative Oncology, Vancouver, Canada
| |
Collapse
|
8
|
Sekar SKV, Pacheco A, Martella P, Li H, Lanka P, Pifferi A, Andersson-Engels S. Solid phantom recipe for diffuse optics in biophotonics applications: a step towards anatomically correct 3D tissue phantoms. BIOMEDICAL OPTICS EXPRESS 2019; 10:2090-2100. [PMID: 31061772 PMCID: PMC6484985 DOI: 10.1364/boe.10.002090] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 02/19/2019] [Accepted: 02/19/2019] [Indexed: 05/19/2023]
Abstract
We present a tissue mimicking optical phantom recipe to create robust well tested solid phantoms. The recipe consists of black silicone pigment (absorber), silica microspheres (scatterer) and silicone rubber (SiliGlass, bulk material). The phantom recipe was characterized over a broadband spectrum (600-1100 nm) for a wide range of optical properties (absorption 0.1-1 cm-1, reduced scattering 5-25 cm-1) that are relevant to human organs. The results of linearity show a proper scaling of optical properties as well as the absence of coupling between the absorber and scatterer at different concentrations. A reproducibility of 4% among different preparations was obtained, with a similar grade of spatial homogeneity. Finally, a 3D non-scattering mock-up phantom of an infant torso made with the same recipe bulk material (SiliGlass) was presented to project the futuristic aspect of our work that is 3D printing human organs of biomedical relevance.
Collapse
Affiliation(s)
| | - Andrea Pacheco
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, Lee Maltings, Dyke Parade, Cork, Ireland
- Department of Physics, University College Cork, College Road, Cork, T12 K8AF, Ireland
| | - Pierluigi Martella
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, Lee Maltings, Dyke Parade, Cork, Ireland
- Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Pavia, Italy
| | - Haiyang Li
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, Lee Maltings, Dyke Parade, Cork, Ireland
- School of Mechanical Engineering and Automation, Northeastern University, China
| | - Pranav Lanka
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| | - Antonio Pifferi
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Milano, Italy
| | - Stefan Andersson-Engels
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, Lee Maltings, Dyke Parade, Cork, Ireland
- Department of Physics, University College Cork, College Road, Cork, T12 K8AF, Ireland
| |
Collapse
|
9
|
Louie DC, Phillips J, Tchvialeva L, Kalia S, Lui H, Wang W, Lee TK. Degree of optical polarization as a tool for detecting melanoma: proof of principle. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-7. [PMID: 30554501 DOI: 10.1117/1.jbo.23.12.125004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 11/26/2018] [Indexed: 05/14/2023]
Abstract
Determining the optical polarization properties of a skin lesion is a proposed method to differentiate melanoma from other skin lesions. We developed an in vivo Stokes polarimetry probe that fires a laser of known polarization at the skin and measures the Stokes parameters of the backscattered light in one shot. From these measured Stokes parameters, we can calculate the degree of polarization (DOP). Through testing on rough skin phantoms, a correlation between backscattered DOP and skin roughness was identified for both linear and circular input polarization, the latter of which was found to be more useful. In a pilot clinical trial of 69 skin lesions in vivo, it was found that the mean DOP for melanoma (linear input on melanoma: 0.46 ± 0.09) was greater than that of other lesions (linear input on all other lesions: 0.28 ± 0.01). This separation is greater for circular polarized input light, and it is likely that circular polarized light's greater sensitivity to surface roughness contributes to this result. In addition, all skin lesions demonstrated a stronger depolarizing effect on circular polarized light than linear polarized light. We have identified DOP as a potentially useful measurement to identify melanoma among other types of skin lesions.
Collapse
Affiliation(s)
- Daniel C Louie
- University of British Columbia, School of Biomedical Engineering, Vancouver, Canada
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermat, Canada
| | - Jamie Phillips
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermat, Canada
| | - Lioudmila Tchvialeva
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermat, Canada
| | - Sunil Kalia
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermat, Canada
| | - Harvey Lui
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermat, Canada
- British Columbia Cancer Agency, Department of Cancer Control Research, Vancouver, Canada
- British Columbia Cancer Agency, Department of Integrative Oncology, Vancouver, Canada
| | - Wei Wang
- Heriot-Watt University, School of Engineering and Physical Sciences, Edinburgh, United Kingdom
| | - Tim K Lee
- University of British Columbia, School of Biomedical Engineering, Vancouver, Canada
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermat, Canada
- British Columbia Cancer Agency, Department of Cancer Control Research, Vancouver, Canada
| |
Collapse
|
10
|
Doronin A, Tchvialeva L, Markhvida I, Lee TK, Meglinski I. Backscattering of linearly polarized light from turbid tissue-like scattering medium with rough surface. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:71117. [PMID: 27401802 DOI: 10.1117/1.jbo.21.7.071117] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Accepted: 06/14/2016] [Indexed: 06/06/2023]
Abstract
In the framework of further development of a unified computational tool for the needs of biomedical optics, we introduce an electric field Monte Carlo (MC) model for simulation of backscattering of coherent linearly polarized light from a turbid tissue-like scattering medium with a rough surface. We consider the laser speckle patterns formation and the role of surface roughness in the depolarization of linearly polarized light backscattered from the medium. The mutual phase shifts due to the photons’ pathlength difference within the medium and due to reflection/refraction on the rough surface of the medium are taken into account. The validation of the model includes the creation of the phantoms of various roughness and optical properties, measurements of co- and cross-polarized components of the backscattered/reflected light, its analysis and extensive computer modeling accelerated by parallel computing on the NVIDIA graphics processing units using compute unified device architecture (CUDA). The analysis of the spatial intensity distribution is based on second-order statistics that shows a strong correlation with the surface roughness, both with the results of modeling and experiment. The results of modeling show a good agreement with the results of experimental measurements on phantoms mimicking human skin. The developed MC approach can be used for the direct simulation of light scattered by the turbid scattering medium with various roughness of the surface.
Collapse
Affiliation(s)
- Alexander Doronin
- Yale University, Department of Computer Science, Computer Graphics Group, New Haven 06511, United States
| | - Lioudmila Tchvialeva
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Photomedicine Institute, Vancouver V5Z 4E8, Canada
| | - Igor Markhvida
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Photomedicine Institute, Vancouver V5Z 4E8, Canada
| | - Tim K Lee
- University of British Columbia and Vancouver Coastal Health Research Institute, Department of Dermatology and Skin Science, Photomedicine Institute, Vancouver V5Z 4E8, CanadacBC Cancer Agency, Departments of Cancer Control Research and Integrative Oncolog
| | - Igor Meglinski
- University of Oulu, Opto-Electronics and Measurement Techniques Laboratory, Oulu FI-9014, Finland
| |
Collapse
|