1
|
Zhao W, Shen S, Ke T, Jiang J, Wang Y, Xie X, Hu X, Tang X, Han D, Chen J. Clinical value of dual-energy CT for predicting occult metastasis in central neck lymph nodes of papillary thyroid carcinoma. Eur Radiol 2024; 34:16-25. [PMID: 37526667 DOI: 10.1007/s00330-023-10004-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 05/09/2023] [Accepted: 06/06/2023] [Indexed: 08/02/2023]
Abstract
OBJECTIVES To predict the probability of occult lymph node metastasis (OLNM) in the central cervical by analyzing the dual-energy computed tomography (DECT) parameters derived from papillary thyroid carcinoma (PTC). METHODS Data were retrospectively collected from patients with pathologically confirmed PTC who underwent arterial and venous phases of enhanced DECT with concurrent central neck lymph node dissection (CLND). Three clinical features, three shape-related features, and twenty-six DECT-derived parameters were measured. The univariate and multivariate analyses were applied to select the relevant parameters and develop the nomogram. RESULTS A total 140 cases with negative diagnosis of cervical central lymph node metastases by preoperative evaluation were included, among which 88 patients with metastasis (OLNM +) and 52 patients without metastasis (OLNM -) were finally confirmed by pathology. (1) Anteroposterior/transverse diameter ratio (A/T) derived from the PTC focus had significant difference between the OLNM + and OLNM - groups (p < 0.05). (2) In the arterial phase, iodine concentration (ICarterial), normalized iodine concentration (NICarterial), effective atomic number (Zeff-arterial), electron density (EDarterial), and slope of energy curve (karterial) from PTC focus showed significant difference (all p < 0.05) between the two groups. In the venous phase, only the CT value under the 40 keV (HU40keVvenous) had differences (p < 0.05). (3) The nomogram was produced to predict the probability of OLNM, and the AUC, sensitivity, and specificity in the training and test cohort were 0.830, 75.0%, 76.9%, and 0.829, 65.9%, 84.6%, respectively. CONCLUSIONS DECT parameters combined with shape-related feature derived from PTC might be used as predictors of OLNM in the central neck. CLINICAL RELEVANCE STATEMENT Preoperative imaging evaluation combining shape-related features and dual-energy CT parameters could serve as a reference to discern occult lymph node metastasis in central neck during the surgically planning of papillary thyroid carcinoma. KEY POINTS • Papillary thyroid carcinoma (PTC) patients may have occult lymph node metastasis (OLNM) in the central neck, which is extremely difficult to find by preoperative imaging examination. • Dual-energy CT quantitative evaluation has higher accuracy than conventional CT and can predicting OLNM in the central neck of PTC. • Dual-energy CT quantitative parameters and morphology of PTC can serve as a useful tool in predicting OLNM in the central neck, and as a guide for personalized treatment.
Collapse
Affiliation(s)
- Wen Zhao
- Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Shasha Shen
- Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Tengfei Ke
- Department of Radiology, the Third Affiliated Hospital of Kunming Medical University, Yunnan Cancer Hospital, Kunming, China.
| | - Jie Jiang
- Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Yingxia Wang
- Department of Pathology, the First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Xiaojie Xie
- Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Xingyue Hu
- Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Xiaonan Tang
- Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, China
| | - Dan Han
- Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, China.
| | | |
Collapse
|
2
|
Zimmerman J, Thor D, Poludniowski G. Stopping-power ratio estimation for proton radiotherapy using dual-energy computed tomography and prior-image constrained denoising. Med Phys 2023; 50:1481-1495. [PMID: 36322128 DOI: 10.1002/mp.16063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2022] [Revised: 09/12/2022] [Accepted: 09/26/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Dual-energy computed tomography (DECT) is a promising technique for estimating stopping-power ratio (SPR) for proton therapy planning. It is known, however, that deriving electron density (ED) and effective atomic number (EAN) from DECT data can cause noise amplification in the resulting SPR images. This can negate the benefits of DECT. PURPOSE This work introduces a new algorithm for estimating SPR from DECT with noise suppression, using a pair of CT scans with spectral separation. The method is demonstrated using phantom measurements. MATERIALS AND METHODS An iterative algorithm is presented, reconstructing ED and EAN with noise suppression, based on Prior Image Constrained Denoising (PIC-D). The algorithm is tested using a Siemens Definition AS+ CT scanner (Siemens Healthcare, Forchheim, Germany). Three phantoms are investigated: a calibration phantom (CIRS 062M), a QA phantom (CATPHAN 700), and an anthropomorphic head phantom (CIRS 731-HN). A task-transfer function (TTF) and the noise power spectrum are derived from SPR images of the QA phantom for the evaluation of image quality. Comparisons of accuracy and noise for ED, EAN, and SPR are made for various versions of the algorithm in comparison to a solution based on Siemens syngo.via Rho/Z software and the current clinical standard of a single-energy CT stoichiometric calibration. A gamma analysis is also applied to the SPR images of the head phantom and water-equivalent distance (WED) is evaluated in a treatment planning system for a proton treatment field. RESULTS The algorithm is effective at suppressing noise in both ED and EAN and hence also SPR. The noise is tunable to a level equivalent to or lower than that of the syngo.via Rho/Z software. The spatial resolution (10% and 50% frequencies in the TTF) does not degrade even for the highest noise suppression investigated, although the average spatial frequency of noise does decrease. The PIC-D algorithm showed better accuracy than syngo.via Rho/Z for low density materials. In the calibration phantom, it was superior even when excluding lung substitutes, with root-mean-square deviations for ED and EAN less than 0.3% and 2%, respectively, compared to 0.5% and 3%. In the head phantom, however, the SPR accuracy of the PIC-D algorithm was comparable (excluding sinus tissue) to that derived from syngo.via Rho/Z: less than 1% error for soft tissue, brain, and trabecular bone substitutes and 5-7% for cortical bone, with the larger error for the latter likely related to the phantom geometry. Gamma evaluation showed that PIC-D can suppress noise in a patient-like geometry without introducing substantial errors in SPR. The absolute pass rates were almost identical for PIC-D and syngo.via Rho/Z. In the WED evaluations no general differences were shown. CONCLUSIONS The PIC-D DECT algorithm provides scanner-specific calibration and tunable noise suppression. It is vendor agnostic and applicable to any pair of CT scans with spectral separation. Improved accuracy to current methods was not clearly demonstrated for the complex geometry of a head phantom, but the suppression of noise without spatial resolution degradation and the possibility of incorporating constraints on image properties, suggests the usefulness of the approach.
Collapse
Affiliation(s)
- Jens Zimmerman
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden
| | - Daniel Thor
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden
| | - Gavin Poludniowski
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
3
|
Yang M, Wohlfahrt P, Shen C, Bouchard H. Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential. Phys Med Biol 2023; 68. [PMID: 36595276 DOI: 10.1088/1361-6560/acabfa] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power (ρs) within patients. Currently, theρsdistribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel toρsusing a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU andρsshare a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) forρsprediction has been shown to be effective in reducing the uncertainty inρsestimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy ofρsestimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods forρsestimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyondρsestimation.
Collapse
Affiliation(s)
- Ming Yang
- The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, 1515 Holcombe Blvd Houston, TX 77030, United States of America
| | - Patrick Wohlfahrt
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA 02115, United States of America
| | - Chenyang Shen
- University of Texas Southwestern Medical Center, Department of Radiation Oncology, 2280 Inwood Rd Dallas, TX 75235, United States of America
| | - Hugo Bouchard
- Département de physique, Université de Montréal, Complexe des sciences, 1375 Avenue Thérèse-Lavoie-Roux, Montréal, Québec H2V0B3, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal, 900 Rue Saint-Denis, Montréal, Québec, H2X 0A9, Canada.,Département de radio-oncologie, Centre hospitalier de l'Université de Montréal, 1051 Rue Sanguinet, Montréal, Québec H2X 3E4, Canada
| |
Collapse
|
4
|
Näsmark T, Andersson J. Proton stopping power prediction based on dual-energy CT-generated virtual monoenergetic images. Med Phys 2021; 48:5232-5243. [PMID: 34213768 DOI: 10.1002/mp.15066] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The purpose of this work was to assess a proof of concept for a novel method for predicting proton stopping power ratios (SPRs) based on a pair of dual-energy CT generated virtual monoenergetic (VM) images. MATERIALS AND METHODS A rapid kV-switching dual-energy CT scanner was used to acquire Gemstone Spectral Imaging (GSI) and 120 kV conventional single-energy CT (SECT) image data of the CIRS 062M phantom. The proposed method was applied to every possible pairing of VM images between 40 and 140 keV to find the optimal energy pairs for SPR prediction in lung tissue, soft tissue, and bone. The predicted SPRs were compared against SPRs predicted from the SECT data using the conventional SECT-based method. The impact of different scan and reconstruction parameters was also investigated. RESULTS The SPR residual root mean square errors (RMSE) yielded by the optimal pairs were 7.2% for lung tissue, 0.4% for soft tissue, and 0.8% for bone. While no direct comparison could be made to other DECT-based methods for SPR prediction, as these methods could not be directly implemented on a fast kV-switching system, the SPR RMSEs for soft tissue and bone in Table 4 are comparable to RMSEs reported in the literature. For the conventional SECT-based method, the SPR RMSEs were 5.9% for lung tissue, 0.9% for soft tissue, and 5.1% for bone. CONCLUSIONS The proposed method is a valid alternative to, and has the potential to improve upon, the conventional SECT-based method for predicting SPRs. The formalism used in the method is applied directly, with no approximations made on our part, and requires neither prior knowledge of the spectra nor calibration with a phantom. This work presents a way of optimizing the proposed method for a specific scanner by determining the optimal energy pairs to use as input and demonstrates the method's robustness to different levels of ASiR-V, reconstruction kernels, and dose levels.
Collapse
Affiliation(s)
- Torbjörn Näsmark
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| | - Jonas Andersson
- Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå, Sweden
| |
Collapse
|
5
|
Birnbacher L, Braig EM, Pfeiffer D, Pfeiffer F, Herzen J. Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography. Eur J Nucl Med Mol Imaging 2021; 48:4171-4188. [PMID: 33846846 PMCID: PMC8566444 DOI: 10.1007/s00259-021-05259-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 02/11/2021] [Indexed: 11/25/2022]
Abstract
The ability of biomedical imaging data to be of quantitative nature is getting increasingly important with the ongoing developments in data science. In contrast to conventional attenuation-based X-ray imaging, grating-based phase contrast computed tomography (GBPC-CT) is a phase contrast micro-CT imaging technique that can provide high soft tissue contrast at high spatial resolution. While there is a variety of different phase contrast imaging techniques, GBPC-CT can be applied with laboratory X-ray sources and enables quantitative determination of electron density and effective atomic number. In this review article, we present quantitative GBPC-CT with the focus on biomedical applications.
Collapse
Affiliation(s)
- Lorenz Birnbacher
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Eva-Maria Braig
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Franz Pfeiffer
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Julia Herzen
- Physics Department, Munich School of Bioengineering, Technical University of Munich, Munich, Germany.
| |
Collapse
|
6
|
Ates O, Hua CH, Zhao L, Shapira N, Yagil Y, Merchant TE, Krasin M. Feasibility of using post-contrast dual-energy CT for pediatric radiation treatment planning and dose calculation. Br J Radiol 2021; 94:20200170. [PMID: 33201728 DOI: 10.1259/bjr.20200170] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
OBJECTIVES When iodinated contrast is administered during CT simulation, standard practice requires a separate non-contrast CT for dose calculation. The objective of this study is to validate our hypothesis that since iodine affects Hounsfield units (HUs) more than electron density (ED), the information from post-contrast dual-layer CT (DLCT) would be sufficient for accurate dose calculation for both photon and proton therapy. METHODS AND MATERIALS 10 pediatric patients with abdominal tumors underwent DLCT scans before and after iodinated contrast administration for radiotherapy planning. Dose distributions with these DLCT-based methods were compared to those with conventional calibration-curve methods that map HU images to ED and stopping-power ratio (SPR) images. RESULTS For photon plans, conventional and DLCT approaches based on post-contrast scans underestimated the PTV D99 by 0.87 ± 0.70% (p = 0.18) and 0.36 ± 0.31% (p = 0.34), respectively, comparing to their non-contrast optimization plans. Renal iodine concentration was weakly associated with D99 deviation for both conventional (R2 = 0.10) and DLCT (R2 = 0.02) approaches. For proton plans, the clinical target volume D99 errors were 3.67 ± 2.43% (p = 0.0001) and 0.30 ± 0.25% (p = 0.40) for conventional and DLCT approaches, respectively. The proton beam range changed noticeably with the conventional approach. Renal iodine concentration was highly associated with D99 deviation for the conventional approach (R2 = 0.83) but not for DLCT (R2 = 0.007). CONCLUSION Conventional CT with iodine contrast resulted in a large dosimetric error for proton therapy, compared to true non-contrast plans, but the error was less for photon therapy. These errors can be greatly reduced in the case of the proton plans if DLCT is used, raising the possibility of using only a single post-contrast CT for radiotherapy dose calculation, thus reducing the time and imaging dose required. ADVANCES IN KNOWLEDGE This study is the first to compare directly the differences in the calculated dose distributions between pre- and post-contrast CT images generated by single-energy CT and dual-energy CT methods for photon and proton therapy.
Collapse
Affiliation(s)
- Ozgur Ates
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Chia-Ho Hua
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Li Zhao
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Nadav Shapira
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.,Global Advanced Technology, Philips Medical Systems, Haifa, Israel
| | - Yoad Yagil
- Global Advanced Technology, Philips Medical Systems, Haifa, Israel
| | - Thomas E Merchant
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Matthew Krasin
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| |
Collapse
|
7
|
Faller FK, Mein S, Ackermann B, Debus J, Stiller W, Mairani A. Pre-clinical evaluation of dual-layer spectral computed tomography-based stopping power prediction for particle therapy planning at the Heidelberg Ion Beam Therapy Center. ACTA ACUST UNITED AC 2020; 65:095007. [DOI: 10.1088/1361-6560/ab735e] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
8
|
Wohlfahrt P, Richter C. Status and innovations in pre-treatment CT imaging for proton therapy. Br J Radiol 2020; 93:20190590. [PMID: 31642709 PMCID: PMC7066941 DOI: 10.1259/bjr.20190590] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 10/04/2019] [Accepted: 10/21/2019] [Indexed: 12/19/2022] Open
Abstract
Pre-treatment CT imaging is a topic of growing importance in particle therapy. Improvements in the accuracy of stopping-power prediction are demanded to allow for a dose conformality that is not inferior to state-of-the-art image-guided photon therapy. Although range uncertainty has been kept practically constant over the last decades, recent technological and methodological developments, like the clinical application of dual-energy CT, have been introduced or arise at least on the horizon to improve the accuracy and precision of range prediction. This review gives an overview of the current status, summarizes the innovations in dual-energy CT and its potential impact on the field as well as potential alternative technologies for stopping-power prediction.
Collapse
Affiliation(s)
- Patrick Wohlfahrt
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | | |
Collapse
|
9
|
Mei K, Ehn S, Oechsner M, Kopp FK, Pfeiffer D, Fingerle AA, Pfeiffer F, Combs SE, Wilkens JJ, Rummeny EJ, Noël PB. Dual-layer spectral computed tomography: measuring relative electron density. Eur Radiol Exp 2018; 2:20. [PMID: 30175319 PMCID: PMC6103960 DOI: 10.1186/s41747-018-0051-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2018] [Accepted: 05/25/2018] [Indexed: 11/22/2022] Open
Abstract
Background X-ray and particle radiation therapy planning requires accurate estimation of local electron density within the patient body to calculate dose delivery to tumour regions. We evaluate the feasibility and accuracy of electron density measurement using dual-layer computed tomography (DLCT), a recently introduced dual-energy CT technique. Methods Two calibration phantoms were scanned with DLCT and virtual monoenergetic images (VMIs) at 50 keV and 200 keV were generated. We investigated two approaches to obtain relative electron densities from these VMIs: to fit an analytic interaction cross-sectional model and to empirically calibrate a conversion function with one of the phantoms. Knowledge of the emitted x-ray spectrum was not required for the presented work. Results The results from both methods were highly correlated to the nominal values (R > 0.999). Except for the water and lung inserts, the error was within 1.79% (average 1.53%) for the cross-sectional model and 1.61% (average 0.87%) for the calibrated conversion. Different radiation doses did not have a significant influence on the measurement (p = 0.348, 0.167), suggesting that the methods are reproducible. Further, we applied these methods to routine clinical data. Conclusions Our study shows a high validity of electron density estimation based on DLCT, which has potential to improve the procedure and accuracy of measuring electron density in clinical practice.
Collapse
Affiliation(s)
- Kai Mei
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Sebastian Ehn
- 2Department of Physics and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Markus Oechsner
- Department of Radiation Oncology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Felix K Kopp
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.,2Department of Physics and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Alexander A Fingerle
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Franz Pfeiffer
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.,2Department of Physics and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| | - Stephanie E Combs
- Department of Radiation Oncology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Ernst J Rummeny
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Peter B Noël
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.,2Department of Physics and Munich School of BioEngineering, Technical University of Munich, Munich, Germany
| |
Collapse
|
10
|
Birnbacher L, Willner M, Marschner M, Pfeiffer D, Pfeiffer F, Herzen J. Accurate effective atomic number determination with polychromatic grating-based phase-contrast computed tomography. OPTICS EXPRESS 2018; 26:15153-15166. [PMID: 30114766 DOI: 10.1364/oe.26.015153] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Accepted: 04/30/2018] [Indexed: 06/08/2023]
Abstract
The demand for quantitative medical imaging is increasing in the ongoing digitalization. Conventional computed tomography (CT) is energy-dependent and therefore of limited comparability. In contrast, dual-energy CT (DECT) allows for the determination of absolute image contrast quantities, namely the electron density and the effective atomic number, and is already established in clinical radiology and radiation therapy. Grating-based phase-contrast computed tomography (GBPC-CT) is an experimental X-ray technique that also allows for the measurement of the electron density and the effective atomic number. However, the determination of both quantities is challenging when dealing with polychromatic GBPC-CT setups. In this paper, we present how to calculate the effective atomic numbers with a polychromatic, laboratory GBPC-CT setup operating between 35 and 50\,kVp. First, we investigated the accuracy of the measurement of the attenuation coefficients and electron densities. For this, we performed a calibration using the concept of effective energy. With the reliable experimental quantitative values, we were able to evaluate the effective atomic numbers of the investigated materials using a method previously shown with monochromatic X-ray radiation. In detail, we first calculated the ratio of the electron density and attenuation coefficient, which were experimentally determined with our polychromatic GBPC-CT setup. Second, we compared this ratio with tabulated total attenuation cross sections from literature values to determine the effective atomic numbers. Thus, we were able to calculate two physical absolute quantities -- the electron density and effective atomic number -- that are in general independent of the specific experimental conditions like the X-ray beam spectrum or the setup design.
Collapse
|
11
|
Möhler C, Wohlfahrt P, Richter C, Greilich S. On the equivalence of image-based dual-energy CT methods for the determination of electron density and effective atomic number in radiotherapy. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2018; 5:108-110. [PMID: 33884314 PMCID: PMC7808337 DOI: 10.1016/j.phro.2018.03.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 03/13/2018] [Accepted: 03/13/2018] [Indexed: 12/03/2022]
Abstract
Dual-energy computed tomography enables the determination of relative electron density and effective atomic number. As this can increase accuracy in radiotherapy treatment planning, a substantial number of algorithms for the determination of the two quantities has been suggested – most of them based on reconstructed CT images. We show that many of these methods share a common theoretical framework. Equations can be transformed from one method to the other by re-definition of the calibration parameters. We suggest that further work should be spent on practical calibration and the reliability of CT numbers rather than on the theoretical framework.
Collapse
Affiliation(s)
- Christian Möhler
- German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| | - Patrick Wohlfahrt
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, 01307 Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, 01307 Dresden, Germany
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, 01307 Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, 01307 Dresden, Germany.,Department of Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, 01307 Dresden, Germany.,German Cancer Consortium (DKTK), 01307 Dresden, Germany
| | - Steffen Greilich
- German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), 69120 Heidelberg, Germany
| |
Collapse
|
12
|
Zhang S, Han D, Politte DG, Williamson JF, O'Sullivan JA. Impact of joint statistical dual-energy CT reconstruction of proton stopping power images: Comparison to image- and sinogram-domain material decomposition approaches. Med Phys 2018; 45:2129-2142. [PMID: 29570809 DOI: 10.1002/mp.12875] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 02/23/2018] [Accepted: 03/07/2018] [Indexed: 01/30/2023] Open
Abstract
PURPOSE The purpose of this study was to assess the performance of a novel dual-energy CT (DECT) approach for proton stopping power ratio (SPR) mapping that integrates image reconstruction and material characterization using a joint statistical image reconstruction (JSIR) method based on a linear basis vector model (BVM). A systematic comparison between the JSIR-BVM method and previously described DECT image- and sinogram-domain decomposition approaches is also carried out on synthetic data. METHODS The JSIR-BVM method was implemented to estimate the electron densities and mean excitation energies (I-values) required by the Bethe equation for SPR mapping. In addition, image- and sinogram-domain DECT methods based on three available SPR models including BVM were implemented for comparison. The intrinsic SPR modeling accuracy of the three models was first validated. Synthetic DECT transmission sinograms of two 330 mm diameter phantoms each containing 17 soft and bony tissues (for a total of 34) of known composition were then generated with spectra of 90 and 140 kVp. The estimation accuracy of the reconstructed SPR images were evaluated for the seven investigated methods. The impact of phantom size and insert location on SPR estimation accuracy was also investigated. RESULTS All three selected DECT-SPR models predict the SPR of all tissue types with less than 0.2% RMS errors under idealized conditions with no reconstruction uncertainties. When applied to synthetic sinograms, the JSIR-BVM method achieves the best performance with mean and RMS-average errors of less than 0.05% and 0.3%, respectively, for all noise levels, while the image- and sinogram-domain decomposition methods show increasing mean and RMS-average errors with increasing noise level. The JSIR-BVM method also reduces statistical SPR variation by sixfold compared to other methods. A 25% phantom diameter change causes up to 4% SPR differences for the image-domain decomposition approach, while the JSIR-BVM method and sinogram-domain decomposition methods are insensitive to size change. CONCLUSION Among all the investigated methods, the JSIR-BVM method achieves the best performance for SPR estimation in our simulation phantom study. This novel method is robust with respect to sinogram noise and residual beam-hardening effects, yielding SPR estimation errors comparable to intrinsic BVM modeling error. In contrast, the achievable SPR estimation accuracy of the image- and sinogram-domain decomposition methods is dominated by the CT image intensity uncertainties introduced by the reconstruction and decomposition processes.
Collapse
Affiliation(s)
- Shuangyue Zhang
- Department of Electrical and Systems Engineering, Washington University, St. Louis, MO, 63130, USA
| | - Dong Han
- Medical Physics Graduate Program, Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA, 23298, USA
| | - David G Politte
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO, 63110, USA
| | - Jeffrey F Williamson
- Department of Radiation Oncology, Washington University, St. Louis, MO, 63110, USA
| | - Joseph A O'Sullivan
- Department of Electrical and Systems Engineering, Washington University, St. Louis, MO, 63130, USA
| |
Collapse
|
13
|
Vilches-Freixas G, Taasti VT, Muren LP, Petersen JBB, Létang JM, Hansen DC, Rit S. Comparison of projection- and image-based methods for proton stopping power estimation using dual energy CT. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2017. [DOI: 10.1016/j.phro.2017.08.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
14
|
Bär E, Lalonde A, Royle G, Lu HM, Bouchard H. The potential of dual-energy CT to reduce proton beam range uncertainties. Med Phys 2017; 44:2332-2344. [PMID: 28295434 DOI: 10.1002/mp.12215] [Citation(s) in RCA: 95] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Revised: 02/21/2017] [Accepted: 03/09/2017] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Dual-energy CT (DECT) promises improvements in estimating stopping power ratios (SPRs) for proton therapy treatment planning. Although several comparable mathematical formalisms have been proposed in literature, the optimal techniques to characterize human tissue SPRs with DECT in a clinical environment are not fully established. The aim of this work is to compare the most robust DECT methods against conventional single-energy CT (SECT) in conditions reproducing a clinical environment, where CT artifacts and noise play a major role on the accuracy of these techniques. METHODS Available DECT tissue characterization methods are investigated and their ability to predict SPRs is compared in three contexts: (a) a theoretical environment using the XCOM cross section database; (b) experimental data using a dual-source CT scanner on a calibration phantom; (c) simulations of a virtual humanoid phantom with the ImaSim software. The latter comparison accounts for uncertainties caused by CT artifacts and noise, but leaves aside other sources of uncertainties such as CT grid size and the I-values. To evaluate the clinical impact, a beam range calculation model is used to predict errors from the probability distribution functions determined with ImaSim simulations. Range errors caused by SPR errors in soft tissues and bones are investigated. RESULTS Range error estimations demonstrate that DECT has the potential of reducing proton beam range uncertainties by 0.4% in soft tissues using low noise levels of 12 and 8 HU in DECT, corresponding to 7 HU in SECT. For range uncertainties caused by the transport of protons through bones, the reduction in range uncertainties for the same levels of noise is found to be up to 0.6 to 1.1 mm for bone thicknesses ranging from 1 to 5 cm, respectively. We also show that for double the amount noise, i.e., 14 HU in SECT and 24 and 16 HU for DECT, the advantages of DECT in soft tissues are lost over SECT. In bones however, the reduction in range uncertainties is found to be between 0.5 and 0.9 mm for bone thicknesses ranging from 1 to 5 cm, respectively. CONCLUSION DECT has a clear potential to improve proton beam range predictions over SECT in proton therapy. However, in the current state high levels of noise remain problematic for DECT characterization methods and do not allow getting the full benefits of this technology. Future work should focus on adapting DECT methods to noise and investigate methods based on raw-data to reduce CT artifacts.
Collapse
Affiliation(s)
- Esther Bär
- Acoustics and Ionising Radiation Team, National Physical Laboratory, Teddington, TW11 0LW, UK
- Department of Medical Physics and Biomedical Engineering, University College London, London, WC1E 6BT, UK
| | - Arthur Lalonde
- Départment de physique, Université de Montréal, Montréal, QC, H3T 1J4, Canada
| | - Gary Royle
- Department of Medical Physics and Biomedical Engineering, University College London, London, WC1E 6BT, UK
| | - Hsiao-Ming Lu
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, 02114, USA
| | - Hugo Bouchard
- Acoustics and Ionising Radiation Team, National Physical Laboratory, Teddington, TW11 0LW, UK
- Départment de physique, Université de Montréal, Montréal, QC, H3T 1J4, Canada
- Centre de recherche du Centre hospitalier de l'Université de Montréal, Montréal, QC, H2X 0A9, Canada
| |
Collapse
|
15
|
Möhler C, Wohlfahrt P, Richter C, Greilich S. Methodological accuracy of image-based electron density assessment using dual-energy computed tomography. Med Phys 2017; 44:2429-2437. [PMID: 28397977 DOI: 10.1002/mp.12265] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Revised: 12/28/2017] [Accepted: 03/30/2017] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Electron density is the most important tissue property influencing photon and ion dose distributions in radiotherapy patients. Dual-energy computed tomography (DECT) enables the determination of electron density by combining the information on photon attenuation obtained at two different effective x-ray energy spectra. Most algorithms suggested so far use the CT numbers provided after image reconstruction as input parameters, i.e., are imaged-based. To explore the accuracy that can be achieved with these approaches, we quantify the intrinsic methodological and calibration uncertainty of the seemingly simplest approach. METHODS In the studied approach, electron density is calculated with a one-parametric linear superposition ('alpha blending') of the two DECT images, which is shown to be equivalent to an affine relation between the photon attenuation cross sections of the two x-ray energy spectra. We propose to use the latter relation for empirical calibration of the spectrum-dependent blending parameter. For a conclusive assessment of the electron density uncertainty, we chose to isolate the purely methodological uncertainty component from CT-related effects such as noise and beam hardening. RESULTS Analyzing calculated spectrally weighted attenuation coefficients, we find universal applicability of the investigated approach to arbitrary mixtures of human tissue with an upper limit of the methodological uncertainty component of 0.2%, excluding high-Z elements such as iodine. The proposed calibration procedure is bias-free and straightforward to perform using standard equipment. Testing the calibration on five published data sets, we obtain very small differences in the calibration result in spite of different experimental setups and CT protocols used. Employing a general calibration per scanner type and voltage combination is thus conceivable. CONCLUSION Given the high suitability for clinical application of the alpha-blending approach in combination with a very small methodological uncertainty, we conclude that further refinement of image-based DECT-algorithms for electron density assessment is not advisable.
Collapse
Affiliation(s)
- Christian Möhler
- German Cancer Research Center (DKFZ), Division of Medical Physics in Radiation Oncology, Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Patrick Wohlfahrt
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany
| | - Christian Richter
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden - Rossendorf, Institute of Radiooncology - OncoRay, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.,German Cancer Consortium (DKTK), Dresden, Germany
| | - Steffen Greilich
- German Cancer Research Center (DKFZ), Division of Medical Physics in Radiation Oncology, Heidelberg, Germany.,National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| |
Collapse
|
16
|
Men K, Dai J, Chen X, Li M, Zhang K, Huang P. Dual-energy imaging method to improve the image quality and the accuracy of dose calculation for cone-beam computed tomography. Phys Med 2017; 36:110-118. [PMID: 28410679 DOI: 10.1016/j.ejmp.2017.03.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2016] [Revised: 03/26/2017] [Accepted: 03/28/2017] [Indexed: 01/30/2023] Open
Abstract
PURPOSE To improve the image quality and accuracy of dose calculation for cone-beam computed tomography (CT) images through implementation of a dual-energy cone-beam computed tomography method (DE-CBCT), and evaluate the improvement quantitatively. METHODS Two sets of CBCT projections were acquired using the X-ray volumetric imaging (XVI) system on a Synergy (Elekta, Stockholm, Sweden) system with 120kV (high) and 70kV (low) X-rays, respectively. Then, the electron density relative to water (relative electron density (RED)) of each voxel was calculated using a projection-based dual-energy decomposition method. As a comparison, single-energy cone-beam computed tomography (SE-CBCT) was used to calculate RED with the Hounsfield unit-RED calibration curve generated by a CIRS phantom scan with identical imaging parameters. The imaging dose was measured with a dosimetry phantom. The image quality was evaluated quantitatively using a Catphan 503 phantom with the evaluation indices of the reproducibility of the RED values, high-contrast resolution (MTF50%), uniformity, and signal-to-noise ratio (SNR). Dose calculation of two simulated volumetric-modulated arc therapy plans using an Eclipse treatment-planning system (Varian Medical Systems, Palo Alto, CA, USA) was performed on an Alderson Rando Head and Neck (H&N) phantom and a Pelvis phantom. Fan-beam planning CT images for the H&N and Pelvis phantom were set as the reference. A global three-dimensional gamma analysis was used to compare dose distributions with the reference. The average gamma values for targets and OAR were analyzed with paired t-tests between DE-CBCT and SE-CBCT. RESULTS In two scans (H&N scan and body scan), the imaging dose of DE-CBCT increased by 1.0% and decreased by 1.3%. It had a better reproducibility of the RED values (mean bias: 0.03 and 0.07) compared with SE-CBCT (mean bias: 0.13 and 0.16). It also improved the image uniformity (57.5% and 30.1%) and SNR (9.7% and 2.3%), but did not affect the MTF50%. Gamma analyses of the 3D dose distribution with criteria of 1%/1mm showed a pass rate of 99.0-100% and 85.3-97.6% for DE-CBCT and 73.5-99.1% and 80.4-92.7% for SE-CBCT. The average gamma values were reduced significantly by DE-CBCT (p< 0.05). Gamma index maps showed that matching of the dose distribution between CBCT-based and reference was improved by DE-CBCT. CONCLUSIONS DE-CBCT can achieve both better image quality and higher accuracy of dose calculation, and could be applied to adaptive radiotherapy.
Collapse
Affiliation(s)
- Kuo Men
- National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
| | - Jianrong Dai
- National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
| | - Xinyuan Chen
- National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
| | - Minghui Li
- National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
| | - Ke Zhang
- National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
| | - Peng Huang
- National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
| |
Collapse
|
17
|
Taasti VT, Petersen JBB, Muren LP, Thygesen J, Hansen DC. A robust empirical parametrization of proton stopping power using dual energy CT. Med Phys 2016; 43:5547. [DOI: 10.1118/1.4962934] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|