Bennett JP, Cataldi D, Liu YE, Kelly NN, Quon BK, Gonzalez MC, Heymsfield SB, Shepherd JA. Variations in bioelectrical impedance devices impact raw measures comparisons and subsequent prediction of body composition using recommended estimation equations. Clin Nutr ESPEN 2024; 63:540-550. [PMID: 39047869 DOI: 10.1016/j.clnesp.2024.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Revised: 07/03/2024] [Accepted: 07/09/2024] [Indexed: 07/27/2024]
Abstract
BACKGROUND & AIMS Bioelectrical impedance analysis (BIA) for body composition estimation is increasingly used in clinical and field settings to guide nutrition and training programs. Due to variations among BIA devices and the proprietary prediction equations used, studies have recommended the use of raw measures of resistance (R) and reactance (Xc) within population-specific equations to predict body composition. OBJECTIVE We compared raw measures from three BIA devices to assess inter-device variation and the impact of differences on body composition estimations. METHODS Raw R, Xc, impedance (Z) parameters were measured on a calibrated phantom and athletes using tetrapolar supine (BIASUP4), octapolar supine (BIASUP8), and octapolar standing (BIASTA8) devices. Measures of R and Xc were compared across devices and graphed using BIA vector analysis (BIVA) and raw parameters were entered into recommended athlete-specific equations for predicting fat-free mass (FFM) and appendicular lean soft tissue (ALST). Whole-body FFM and regional ALST were compared across devices and to a criterion five-compartment (5C) model and dual energy X-ray absorptiometry for ALST. RESULTS Data from 73 (23.2 ± 4.8 y) athletes were included in the analyses. Technical differences were observed between Z (range 12.2-50.1Ω) measures on the calibrated phantom. Differences in whole-body impedance were apparent due to posture (technological) and electrode placement (biological) factors. This resulted in raw measures for all three devices showing greater dehydration on BIVA compared to published norms for athletes using a separate BIA device. Compared to the 5C FFM, significant differences (p < 0.05) were observed on all three equations for BIASUP8 and BIASTA8, with constant error (CE) from -2.7 to -4.6 kg; no difference was observed for BIASUP4 or when device-specific algorithms were used. Published equations resulted in differences as large as 8.8 kg FFM among BIA devices. For ALST, even after a correction in the error of the published empirical equation, all three devices showed significant (p < 0.01) CE from -1.6 to -2.9 kg. CONCLUSIONS Raw bioimpedance measurements differ among devices due to technical, technological, and biological factors, limiting interchangeability of data across BIA systems. Professionals should be aware of these factors when purchasing systems, comparing data to published reference ranges, or when applying published empirical body composition prediction equations.
Collapse
Affiliation(s)
- Jonathan P Bennett
- Department of Epidemiology, University of Hawai'i Cancer Center, 701 Ilalo St, Honolulu, HI, 96813, USA.
| | - Devon Cataldi
- Department of Epidemiology, University of Hawai'i Cancer Center, 701 Ilalo St, Honolulu, HI, 96813, USA
| | - Yong En Liu
- Department of Epidemiology, University of Hawai'i Cancer Center, 701 Ilalo St, Honolulu, HI, 96813, USA
| | - Nisa N Kelly
- Department of Epidemiology, University of Hawai'i Cancer Center, 701 Ilalo St, Honolulu, HI, 96813, USA
| | - Brandon K Quon
- Department of Epidemiology, University of Hawai'i Cancer Center, 701 Ilalo St, Honolulu, HI, 96813, USA
| | - Maria Cristina Gonzalez
- Graduate Program in Nutrition and Foods, Federal University of Pelotas, Rua Gomes Carneiro, 01- Centro, 96010-610, Pelotas, Brazil
| | - Steven B Heymsfield
- Pennington Biomedical Research Center, Louisiana State University, 6400 Perkins Rd, Baton Rouge, LA, 70808, USA
| | - John A Shepherd
- Department of Epidemiology, University of Hawai'i Cancer Center, 701 Ilalo St, Honolulu, HI, 96813, USA
| |
Collapse
|
2
|
Fontanier V, Bruchard A, Tremblay M, Mohammed R, da Silva-Oolup S, Suri-Chilana M, Pasquier M, Hachem S, Meyer AL, Honoré M, Vigne G, Bermon S, Murnaghan K, Lemeunier N. Classification of myo-connective tissue injuries for severity grading and return to play prediction: A scoping review. J Sci Med Sport 2024:S1440-2440(24)00257-3. [PMID: 39232948 DOI: 10.1016/j.jsams.2024.07.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 06/28/2024] [Accepted: 07/25/2024] [Indexed: 09/06/2024]
Abstract
OBJECTIVES To conduct a systematic literature search to identify currently used classifications of acute non-contact muscle injuries in sporting adults. DESIGNS Scoping review. METHODS A systematic literature search from January 1, 2010 to April 19, 2022 of Medline and SPORTDiscus yielded 13,426 articles that were screened for eligibility. Findings from included studies were qualitatively synthesized. Classifications and their grading, as well as outcomes and definitions were extracted. RESULTS Twenty-four classifications were identified from the 37 included studies, most of which had low evidence study designs. Majority (57 %) of classifications were published after 2009 and were mostly developed for hamstring or other lower limb injuries. The six most cited classifications accounted for 70 % of the reports (BAMIC, modified Peetrons, Munich, Cohen, Chan and MLG-R). Outcome reporting was sparse, making it difficult to draw conclusions. Still, significant relationships between grading and time to return to play were reported for the BAMIC, modified Peetrons, Munich and Cohen classifications. Other classifications either had a very low number of reported associations, reported no associations, reported inconclusive associations, or did not report an assessment of the association. Other outcomes were poorly investigated. CONCLUSIONS There is no agreed-upon use of muscle classification, and no consensus on definitions and terminology. As a result, reported outcomes and their relationship to severity grading are inconsistent across studies. There is a need to improve the generalizability and applicability of existing classifications and to refine their prognostic value. High-level evidence studies are needed to resolve these inconsistencies.
Collapse
Affiliation(s)
| | | | - Mathieu Tremblay
- Groupe de Recherche sur les Affections Neuromusculosquelettiques, Université du Québec à Trois-Rivières, Canada
| | | | - Sophia da Silva-Oolup
- Undergraduate and Graduate Education Departments: Canadian Memorial Chiropractic College, Canada
| | - Minisha Suri-Chilana
- Undergraduate and Graduate Education Departments: Canadian Memorial Chiropractic College, Canada
| | | | - Sarah Hachem
- Paris-Saclay University, Inserm, "Exposome and Heredity" Team, CESP, France
| | | | | | | | - Stéphane Bermon
- Health and Science Department, World Athletics, Monaco; LAMHESS, Université Côte d'Azur, France
| | - Kent Murnaghan
- Library Services, Canadian Memorial Chiropractic College, Canada
| | - Nadège Lemeunier
- Medinetic Learning, Research Department, France; UMR1295, Toulouse III University, Inserm, Equipe EQUITY, Equipe constitutive du CERPOP, France; Faculty of Health Sciences, Ontario Tech University, Canada
| |
Collapse
|
3
|
Lukaski HC. Using physical activity to advance a career in clinical nutrition. Eur J Clin Nutr 2024; 78:653-658. [PMID: 38438631 PMCID: PMC11300298 DOI: 10.1038/s41430-024-01410-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 01/16/2024] [Accepted: 01/19/2024] [Indexed: 03/06/2024]
Affiliation(s)
- Henry C Lukaski
- Retired, US Department of Agriculture, Agriculture Research Service, Grand Forks Human Nutrition Research Center, Grand Forks, ND, 50202, USA.
- Adjunct Professor, Department of Kinesiology and Public Health Education, University of North Dakota, Grand Forks, ND, 58202, USA.
| |
Collapse
|
4
|
Francisco R, Jesus F, Nunes CL, Alvim M, Campa F, Sardinha LB, Mendonca GV, Lukaski H, Silva AM. Comparison of series and parallel reactance to identify changes in intracellular water in response to physical training in athletes during a sports season. Nutrition 2024; 123:112414. [PMID: 38564838 DOI: 10.1016/j.nut.2024.112414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 01/29/2024] [Accepted: 02/26/2024] [Indexed: 04/04/2024]
Abstract
OBJECTIVE Cross-sectional evidence has demonstrated that parallel reactance obtained by bioelectrical impedance analysis (BIA) may be an alternative to the regularly used series of measurements to predict intracellular water (ICW) in athletes. However, we are not aware of any studies that have determined the predictive role or compared the effectiveness of both series and parallel reactance for tracking ICW changes during an athletic season. The main aim of this study was to determine the predictive role and compare both series and parallel reactance (Xc) in tracking ICW during an athletic season. RESEARCH METHODS AND PROCEDURES This longitudinal study analyzed 108 athletes in the preparatory and competitive periods. Using dilution techniques, total body water (TBW) and extracellular water (ECW) were determined and ICW was calculated. Resistance (R), Xc, and impedance (Z) standardized for height were obtained through BIA spectroscopy using a frequency of 50kHz in a series array and then mathematically transformed in a parallel array. RESULTS Multiple regression analyses showed that only changes in parallel Xc and capacitance (CAP) (P < 0.05) were predictors of delta ICW during the sports season. In contracts, this was not the case for Xcs. Both changes in R and Z, series and parallel, predicted similarly the changes in ECW and TBW (P < 0.05) in athletes. CONCLUSION Our findings highlight the potential of parallel BIA values to detect changes in body water compartments over a competitive season. These data provide preliminary evidence that changes in parallel Xc/H, and ultimately CAP, represent valid markers of alterations in cell volume during a sports season.
Collapse
Affiliation(s)
- Rúben Francisco
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal.
| | - Filipe Jesus
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | | | - Marta Alvim
- National Institute of Health Doutor Ricardo Jorge, Lisbon, Portugal
| | - Francesco Campa
- Department of Biomedical Sciences, University of Padua, Padua, Italy
| | - Luís B Sardinha
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Goncalo V Mendonca
- Neuromuscular Research Lab, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Henry Lukaski
- Department of Kinesiology and Public Health Education, Hyslop Sports Center, University of North Dakota, Grand Forks, North Dakota, USA
| | - Analiza M Silva
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| |
Collapse
|
5
|
Nescolarde L, Yanguas J, Hernández-Hermoso JA. Localized hamstring bioimpedance in marathon runners is related to muscle high-energy enzyme serum levels and predicts race time. Front Physiol 2024; 15:1337119. [PMID: 38505706 PMCID: PMC10948513 DOI: 10.3389/fphys.2024.1337119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 02/12/2024] [Indexed: 03/21/2024] Open
Abstract
Introduction: The aim was to analyze the response of serum levels of inflammatory, high-energy muscle biomarkers and hamstring localized bioimpedance (L-BIA) measurements to marathon running and to ascertain whether they correlate with each other or with race time. Methods: Blood samples and hamstrings tetra-polar L-BIA measurements from 14 Caucasian male recreational athletes at the Barcelona Marathon 2019 were collected at base line, immediately after and 48 h post-race. Serum C reactive protein (sCRP), creatinine kinase (sCK) and lactate dehydrogenase (sLDH) were determined using an AU-5800 chemistry analyzer. L-BIA was obtained at 50 kHz with a Quantum V Segmental phase-sensitive bioimpedance analyzer. Results: Median sCRP increased (4-fold) after 48 h post-race. Median sCK and sLDH levels increased immediately post-race (3-fold, 2-fold) and 48h post-race (5-fold, 1-fold). Left, right and combined hamstring reactance (Xc) and phase angle (PhA) increased immediately post-race. Xc combined hamstring pre- and immediately post-race correlated with race-time and with sCK and sLDH median levels pre-race. Xc combined hamstring pre- and immediately post-race > 15.6 Ω and 15.8 Ω, respectively, predicted the race time of 3:00:00 h. Conclusion: L-BIA reactance (Xc) is an objective direct, real time, easy, noninvasive bioelectrical parameter that may predict muscle and marathon athlete performance.
Collapse
Affiliation(s)
- Lexa Nescolarde
- Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
| | - Javier Yanguas
- FIFA Medical Center of Excellence, Ciutat Esportiva Futbol Club Barcelona, Medical Department, Futbol Club Barcelona, Barcelona, Spain
| | - José A. Hernández-Hermoso
- Department of Orthopedic Surgery and Traumatology, Hospital Universitari Germans Trias i Pujol, Badalona, Spain
- Department of Surgery, Faculty of Medicine, Universitat Autònoma de Barcelona, Barcelona, Spain
| |
Collapse
|
6
|
Cai JH, Chuang CC, Chen MH, Yeh CP, Hsu CY. Differences of bioelectrical impedance in the development and healing phase of pressure ulcers and erythema in mouse model. J Tissue Viability 2024:S0965-206X(24)00025-1. [PMID: 38431432 DOI: 10.1016/j.jtv.2024.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 01/26/2024] [Accepted: 02/24/2024] [Indexed: 03/05/2024]
Abstract
Pressure ulcers (PUs) are economically burdensome medical conditions. Early changes in pressure ulcers are associated with erythema. In this study, bioelectrical impedance was used to measure the differences between PUs and blanchable erythema. We divided 21 ICR mice into three groups: control, 1000 mmHg-1h, and 1000 mmHg-6h. Healthy skin, blanchable erythema, and PUs were induced on the dorsal skin. The results indicated an immediate increase in impedance, resistance, and reactance values in the pressure group after release, followed by a subsequent decrease until two days after release. Compared with the control group, impedance and reactance significantly increased by 30.9% (p < 0.05) and 30.1% (p < 0.01), respectively, in the 6 h-loading group immediately after release. One and two days after release, the 1 h-loading and 6 h-loading groups exhibited significantly different degrees of decline. One day after release, impedance and resistance decreased by 30.2% (p < 0.05) and 19.8% (p < 0.05), respectively, in the 1 h-loading group; while impedance, resistance, and reactance decreased by 39.2% (p < 0.01), 26.8% (p < 0.01), and 45.7% (p < 0.05), respectively, in the 6 h-loading group. Two days after release, in the 1 h-loading group, impedance and resistance decreased by 28.3% (p < 0.05) and 21.7% (p < 0.05), respectively; while in the 6 h-loading group, impedance, resistance, and reactance decreased by 49.8% (p < 0.001), 34.2% (p < 0.001), and 59.8% (p < 0.01), respectively. One and two days after release the pressure group reductions were significantly greater than those in the control group. Additionally, we monitored changes during wound healing. Distinguishing early PUs from blanchable erythema by noninvasive bioelectrical impedance technology may have applications value in early assessment of PUs.
Collapse
Affiliation(s)
- J H Cai
- Department of Biomedical Engineering, Chung Yuan Christian University, Chung Pei Road, Chung Li District, Taoyuan City, Taiwan.
| | - C C Chuang
- Department of Biomedical Engineering, Chung Yuan Christian University, Chung Pei Road, Chung Li District, Taoyuan City, Taiwan.
| | - M H Chen
- Department of Biomedical Engineering, Chung Yuan Christian University, Chung Pei Road, Chung Li District, Taoyuan City, Taiwan.
| | - C P Yeh
- Department of Biomedical Engineering, Chung Yuan Christian University, Chung Pei Road, Chung Li District, Taoyuan City, Taiwan.
| | - C Y Hsu
- Department of Physical Medicine and Rehabilitation, Ten-Chan General Hospital, Yanping Road, Chung Li District, Taoyuan City, Taiwan.
| |
Collapse
|
7
|
Wohlgemuth KJ, Freeborn TJ, Southall KE, Hare MM, Mota JA. Can segmental bioelectrical impedance be used as a measure of muscle quality? Med Eng Phys 2024; 124:104103. [PMID: 38418031 DOI: 10.1016/j.medengphy.2024.104103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 12/11/2023] [Accepted: 01/08/2024] [Indexed: 03/01/2024]
Abstract
Recent works have shown bioelectrical impedance spectroscopy (BIS) may assess tissue quality. The purpose of this project was to examine associations between ultrasound echo intensity (EI) of quadriceps muscles (vastus lateralis [VL], vastus medialis [VM], vastus intermedius [VI], rectus femoris [RF]) and BIS parameters (R0, R1, C, α, fp), and if the associations are specific to individual muscles or associated with a representation of the entire quadriceps. Twenty-two participants (age: 22 ± 4 years; BMI: 25.47 ± 3.26 kg/m2) participated in all study activities. Participants had transverse ultrasound scans of each individual quadriceps muscle taken at 25, 50, and 75 % of the muscle length to generate an average EI for the VL, VM, VI, and RF, which were further averaged to generate an EI for the entire quadriceps. For BIS, participants were seated with electrodes placed on the thigh to measure the segmental quadriceps. The Cole-impedance model parameters that best fit the BIS data for each participant was used for all analyses. Pearson's correlation coefficient (r) were calculated to determine associations between muscles' EI and BIS parameters. The results suggest averaged EI of individual VL, VM, VI, RF muscles and the average EI of the segmental quadriceps were significantly related to the R0, C, α metrics of the Cole-impedance model representing quadriceps segmental tissues. This supports that segmental BIS may be an appropriate technique for rapid evaluation of segmental muscle quality.
Collapse
Affiliation(s)
- Kealey J Wohlgemuth
- Neuromuscular and Occupational Performance Laboratory, Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, US
| | - Todd J Freeborn
- Electrical and Computer Engineering, Integrative Center for Athletic and Sport Technology, College of Engineering, University of Alabama, Tuscaloosa, AL, US
| | - Kathyrn E Southall
- Neuromuscular and Occupational Performance Laboratory, Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, US
| | - McKenzie M Hare
- Neuromuscular and Occupational Performance Laboratory, Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, US
| | - Jacob A Mota
- Neuromuscular and Occupational Performance Laboratory, Department of Kinesiology and Sport Management, Texas Tech University, Lubbock, TX, US.
| |
Collapse
|
8
|
Francisco R, Jesus F, Nunes CL, Carvalho A, Alvim M, Campa F, Sardinha LB, Mendonca GV, Lukaski H, Silva AM. Prediction of body water compartments by raw bioelectrical impedance parameters in athletes: Comparison between series and parallel measurements. Scand J Med Sci Sports 2023; 33:1998-2008. [PMID: 37403709 DOI: 10.1111/sms.14443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 06/02/2023] [Accepted: 06/22/2023] [Indexed: 07/06/2023]
Abstract
BACKGROUND The aim of this study was to determine the predictive role of series and parallel bioelectrical impedance-derived parameters in predicting total body (TBW), intracellular (ICW), and extracellular water (ECW) in athletes. METHODS This cross-sectional study analyzed 134 male (21.33 ± 5.11 years) and 64 female (20.45 ± 5.46 years) athletes. Using dilution techniques, TBW and ECW were determined while ICW was the difference between both. Raw and standardized for height (/H) bioelectrical resistance (R), reactance (Xc), and impedance (Z) values were obtained using a phase-sensitive device at a single frequency in a series array (s). These were mathematically transformed in a parallel array (p) and capacitance (CAP). Fat-free mass (FFM) was assessed by dual-energy X-ray absorptiometry. RESULTS Multiple regressions adjusted for age and FFM show that R/Hs, Z/Hs, R/Hp, and Z/Hp were significant predictors of TBW (p < 0.001 in females and males). While Xc/Hs did not predict ICW, Xc/Hp was a predictor (p < 0.001 in females and Males). In females, R/H and Z/H predicted similarly TBW, ICW, and ECW. In males, R/Hs was considered a better predictor than R/Hp for TBW and ICW, and the Xc/Hp was considered the best predictor for ICW. Another significant predictor of ICW was CAP (p < 0.001 in females and males). CONCLUSION This study highlights the potential value of parallel bioelectrical impedance values to identify fluid compartments in athletes as an alternative to the regularly used series measurements. Moreover, this study supports Xc in parallel, and ultimately CAP, as valid indicators of cell volume.
Collapse
Affiliation(s)
- Rúben Francisco
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Filipe Jesus
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Catarina L Nunes
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - André Carvalho
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Marta Alvim
- National Institute of Health Doutor Ricardo Jorge, Lisbon, Portugal
| | - Francesco Campa
- Department of Biomedical Sciences, University of Padua, Padua, Italy
| | - Luís B Sardinha
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Goncalo V Mendonca
- Neuromuscular Research Lab, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | - Henry Lukaski
- Department of Kinesiology and Public Health Education, Hyslop Sports Center, University of North Dakota, Grand Forks, North Dakota, USA
| | - Analiza M Silva
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| |
Collapse
|
9
|
Nescolarde L, Talluri A, Yanguas J, Lukaski H. Phase angle in localized bioimpedance measurements to assess and monitor muscle injury. Rev Endocr Metab Disord 2023; 24:415-428. [PMID: 36847994 PMCID: PMC10140135 DOI: 10.1007/s11154-023-09790-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/27/2023] [Indexed: 02/28/2023]
Abstract
Localized bioimpedance (L-BIA) measurements are an innovative method to non-invasively identify structural derangement of soft tissues, principally muscles, and fluid accumulation in response to traumatic injury. This review provides unique L-BIA data demonstrating significant relative differences between injured and contralateral non-injured regions of interest (ROI) associated with soft tissue injury. One key finding is the specific and sensitive role of reactance (Xc), measured at 50 kHz with a phase-sensitive BI instrument, to identify objective degrees of muscle injury, localized structural damage and fluid accretion, determined using magnetic resonance imaging. The predominant effect of Xc as an indicator of severity of muscle injury is highlighted in phase angle (PhA) measurements. Novel experimental models utilizing cooking-induced cell disruption, saline injection into meat specimens, and measurements of changing amounts of cells in a constant volume provide empirical evidence of the physiological correlates of series Xc as cells in water. Findings of strong associations of capacitance, computed from parallel Xc (XCP), with whole body counting of 40-potassium and resting metabolic rate support the hypothesis that parallel Xc is a biomarker of body cell mass. These observations provide a theoretical and practical basis for a significant role of Xc, and hence PhA, to identify objectively graded muscle injury and to reliably monitor progress of treatment and return of muscle function.
Collapse
Affiliation(s)
- Lexa Nescolarde
- Department of Electronic Engineering, Universitat Politècnica de Catalunya, c/ Jordi Girona 1-3, Edifici C4, 08034, Barcelona, Spain.
| | | | - Javier Yanguas
- Futbol Club Barcelona, Ciutat Esportiva Joan Gamper, Av. c/ Onze de Setembre s/n, 08790, Sant Joan Despí, Barcelona, Spain
| | - Henry Lukaski
- Department of Kinesiology and Public Health Education, University of North Dakota, Grand Forks, ND, 58202, USA
| |
Collapse
|
10
|
Pîslaru-Dănescu L, Zărnescu GC, Telipan G, Stoica V. Design and Manufacturing of Equipment for Investigation of Low Frequency Bioimpedance. MICROMACHINES 2022; 13:1858. [PMID: 36363879 PMCID: PMC9698562 DOI: 10.3390/mi13111858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 10/22/2022] [Accepted: 10/25/2022] [Indexed: 06/16/2023]
Abstract
The purpose of this study was to highlight a method of making equipment for the investigation of low frequency bioimpedance. A constant current with an average value of I = 100 µA is injected into the human body via means of current injection electrodes, and the biological signal is taken from the electrodes of electric potential charged with the biopotentials generated by the human body. The resulting voltage, ΔU is processed by the electronic conditioning system. The mathematical model of the four-electrode system in contact with the skin, and considering a target organ, was simplified to a single equivalent impedance. The capacitive filter low passes down from the differential input of the first instrumentation amplifier together with the isolated capacitive barrier integrated in the precision isolated secondary amplifier and maintains the biological signal taken from the electrodes charged with the undistorted biopotentials generated by the human body. Mass loops are avoided, and any electric shocks or electrostatic discharges are prevented. In addition, for small amplitudes of the biological signal, electromagnetic interferences of below 100 Hz of the power supply network were eliminated by using an active fourth-order Bessel filtering module. The measurements performed for the low frequency of f = 100 Hz on the volunteers showed for the investigated organs that the bioelectrical resistivities vary from 90 Ωcm up to 450 Ωcm, and that these are in agreement with other published and disseminated results for each body zone.
Collapse
|
11
|
Celicanin M, Harrison AP, Olsen JK, Korbo L, Løkkegård A, Petersen CB, Danneskiold‐Samsøe B, Siebner HR, Ilic T, Bartels EM. Probing cellular health at the muscle level-Multi-frequency bioimpedance in Parkinson's disease. Physiol Rep 2022; 10:e15465. [PMID: 36200221 PMCID: PMC9535347 DOI: 10.14814/phy2.15465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 08/24/2022] [Accepted: 08/25/2022] [Indexed: 06/16/2023] Open
Abstract
Bioimpedance (mfBIA) non-invasively assesses cellular muscle health. Our aim was to explore whether mfBIA captures abnormal cellular muscle health in patients with Parkinson's Disease (PD) and how such changes are modulated with the use of Parkinson's medication. In patients with PD (n = 20) mfBIA measurements were made of biceps brachii, triceps, and extensor carpi radialis longus muscles of the more affected arm whilst at rest, using a mobile mfBIA device (IMPEDIMED, Australia). mfBIA and assessment of motor symptoms were performed in a pragmatic off-medication state, as well as one and 3 h after oral intake of 200 mg levodopa. Age and sex-matched healthy subjects (HC; n = 20) served as controls. PD and HC mfBIA parameters were compared by applying an unpaired two-tailed adjusted t-test and ANOVA with Tukey's correction for multiple comparisons (p ≤ 0.05). The PD group consisted of 13 men (71 ± 17 years) and 7 women (65 ± 7 years). Independent of medication, internal (Ri ) and external resistance (Re ) were found to be significantly higher, and membrane capacitance (Mc) significantly lower, in m.biceps brachii in PD subjects compared to HC. Center frequency (fc) was significantly higher in m.biceps brachii of PD subjects in the "medication-off" state. There was no difference between PD and HC in mfBIA parameters in the measured extensor muscles. The upper limb flexor muscle shows a difference in mfBIA parameters in PD compared to HC. mfBIA may be useful in the diagnosis and assessment of PD patients and is objective, non-invasive, reliable, and easy to use.
Collapse
Affiliation(s)
- Marko Celicanin
- Department of NeurologyCopenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
- The Parker Institute, Copenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
| | - Adrian Paul Harrison
- Faculty of Health and Medical SciencesUniversity of Copenhagen, IVH, PAS (Excitable Tissues & Biomechanics)CopenhagenDenmark
| | - Jack Kvistgaard Olsen
- The Parker Institute, Copenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
| | - Lise Korbo
- Department of NeurologyCopenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
| | - Annemette Løkkegård
- Department of NeurologyCopenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
| | - Charlotte Bjerg Petersen
- Department of NeurologyCopenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
| | - Bente Danneskiold‐Samsøe
- The Parker Institute, Copenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
| | - Hartwig Roman Siebner
- Department of NeurologyCopenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
- Faculty of Health and Medical SciencesUniversity of Copenhagen, IVH, PAS (Excitable Tissues & Biomechanics)CopenhagenDenmark
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and ResearchCopenhagen University Hospital Amager and HvidovreHvidovreDenmark
| | - Tihomir Ilic
- Department of Neurophysiology, Medical Faculty of Military Medical AcademyUniversity of DefenseBelgradeSerbia
| | - Else Marie Bartels
- Department of NeurologyCopenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
- The Parker Institute, Copenhagen University Hospital, Bispebjerg and FrederiksbergCopenhagenDenmark
| |
Collapse
|
12
|
Ye X, Wu L, Mao K, Feng Y, Li J, Ning L, Chen J. Bioimpedance Measurement of Knee Injuries Using Bipolar Electrode Configuration. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:962-971. [PMID: 35994551 DOI: 10.1109/tbcas.2022.3200355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Currently, there is no suitable solution for the point-of-care diagnosis of knee injuries. A potential portable and low-cost technique for accessing and monitoring knee injuries is bioimpedance measurement. This study validated the feasibility of the bipolar electrode configuration for knee bioimpedance measurement with two electrodes placed on a fixed pair of knee acupuncture locations called Xiyan. Then, the study collected 76 valid samples to investigate the relationship between bioimpedance and knee injuries, among whom 39 patients have unilateral knee injuries, and 37 individuals have healthy knees. The self-contrast results indicated that knee injuries caused a reduction of bioimpedance of the knee by about 5% on average, which was detectable at around 100 kHz (p ≈ 0.001). Furthermore, the results analyzed by principal component analysis and support vector machines show that the detection sensitivity can reach 87.18% using the leave-one-out cross-validation. We also proposed a low-cost and portable bioimpedance measurement device that meets the needs for measuring knee joint bioimpedance.
Collapse
|
13
|
Changes in Intra-to-Extra-Cellular Water Ratio and Bioelectrical Parameters from Day-Before to Day-Of Competition in Bodybuilders: A Pilot Study. Sports (Basel) 2022; 10:sports10020023. [PMID: 35202062 PMCID: PMC8880471 DOI: 10.3390/sports10020023] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 02/09/2022] [Accepted: 02/10/2022] [Indexed: 01/06/2023] Open
Abstract
The present study analyzed the effects from day-before to day-of bodybuilding competition on intracellular water (ICW), extracellular water (ECW), total body water (TBW), and bioimpedance analysis (BIA) parameters (resistance, R; reactance, Xc; and derived scores) in bodybuilding athletes. We assessed anthropometry and BIA (foot-to-hand; tetrapolar; 50 kHz) in 11 male bodybuilders (29 ± 4 year-old; 81 ± 8 kg; 172 ± 7 cm; 27 ± 2 kg/m2) both on the pre-competition day and on the contest day. Results revealed significant increases in ICW (31.6 ± 2.9 to 33.1 ± 2.8 L), with concomitant decreases in ECW (19.8 ± 1.8 to 17.2 ± 1.4 L) and TBW (51.4 ± 4.6 to 50.3 ± 4.2 L) from the day-before competition to contest day, which resulted in relatively large increases in the ICW/ECW ratio (1.60 ± 0.03 to 1.92 ± 0.01 L). Moreover, significant increases in R (391 ± 34 to 413 ± 33 ohm), Xc (64 ± 7 to 70 ± 6 ohm), and phase angle (9.3 ± 0.6 to 9.6 ± 0.7 degree) were observed between time periods. The phase angle scores reported on show-day of 9.6 and 11.2 appear to be the highest group mean and individual values observed in the literature to date. In conclusion, the strategies carried out on the final day of peak-week bodybuilding preparation lead to changes in BIA parameters and body water, with fluids shifting from the extra- to the intracellular compartment.
Collapse
|
14
|
Grange S, Reurink G, Nguyen AQ, Riviera-Navarro C, Foschia C, Croisille P, Edouard P. Location of Hamstring Injuries Based on Magnetic Resonance Imaging: A Systematic Review. Sports Health 2022; 15:111-123. [PMID: 35148645 PMCID: PMC9808837 DOI: 10.1177/19417381211071010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
CONTEXT Hamstring muscle injury location using magnetic resonance imaging (MRI) is not so well described in the literature. OBJECTIVE To describe the location of hamstring injuries using MRI. DATA SOURCES PubMed, Web of Science, Scopus, SPORTDiscus, Cochrane Library. STUDY SELECTION The full text of studies, in English, had to be available. Case reports and reviews were excluded. Included studies must report the location of hamstring injuries using MRI within 8 days of the acute injury. STUDY DESIGN Systematic review. LEVEL OF EVIDENCE Level 4. DATA EXTRACTION A first screening was conducted based on title and abstract of the articles. In the second screening, the full text of the remaining articles was evaluated for the fulfillment of the inclusion criteria. RESULTS From the 2788 references initially found in 5 databases, we included 34 studies, reporting a total of 2761 acute hamstring injuries. The most frequent muscle head involved was the long head of the biceps femoris (BFLH) (70%), followed by the semitendinosus (ST) (15%), generally associated with BFLH. The most frequent tissue affected was the myotendinous junction (MTJ) accounting for half the cases (52%). Among all lesions, the distribution between proximal, central, and distal lesions looked homogenous, with 34.0%, 33.4% and 32.6%, respectively. The stretching mechanism, while only reported in 2 articles, represented 3% of all reported mechanisms, appears responsible for a specific lesion involving the proximal tendon of the semimembranosus (SM), and leading to a longer time out from sport. CONCLUSION BFLH was the most often affected hamstring injuries and MTJ was the most affected tissue. In addition, the distal, central, and proximal locations were homogeneously distributed. We also noted that MRI descriptions of hamstring injuries are often poor and did not take full advantage of the MRI strengths. SYSTEMATIC REVIEW REGISTRATION Before study initiation, the study was registered in the PROSPERO International prospective register of systematic reviews (registration number CRD42018107580).
Collapse
Affiliation(s)
- Sylvain Grange
- Inter-university Laboratory of Human
Movement Science (LIBM EA 7424), University of Lyon, University Jean Monnet, Saint
Etienne, France,CREATIS, UMR CNRS 5220–INSERM U1206,
F-69621, Villeurbanne, France,Department of Radiology, University
Hospital of Saint-Etienne, Saint-Etienne, France,Sylvain Grange, MD,
Département de Radiologie, Hôpital Nord, CHU de Saint-Etienne, 42055
Saint-Etienne cedex 2, France (
)
| | - Gustaaf Reurink
- Department of Orthopedic Surgery,
Academic Medical Center, University of Amsterdam, Amsterdam Movement Sciences,
Amsterdam, The Netherlands,Academic Center for Evidence-Based
Sports Medicine (ACES), Academic Medical Center, Amsterdam, The Netherlands,The Sports Physicians Group, Onze Lieve
Vrouwe Gasthuis, Amsterdam, The Netherlands
| | - Anh Quoc Nguyen
- Department of Radiology, University
Hospital of Saint-Etienne, Saint-Etienne, France
| | - Camille Riviera-Navarro
- Department of Clinical and Exercise
Physiology, Sports Medicine Unity, University Hospital of Saint-Etienne,
Saint-Etienne, France
| | - Clément Foschia
- Department of Clinical and Exercise
Physiology, Sports Medicine Unity, University Hospital of Saint-Etienne,
Saint-Etienne, France
| | - Pierre Croisille
- CREATIS, UMR CNRS 5220–INSERM U1206,
F-69621, Villeurbanne, France,Department of Radiology, University
Hospital of Saint-Etienne, Saint-Etienne, France
| | - Pascal Edouard
- Inter-university Laboratory of Human
Movement Science (LIBM EA 7424), University of Lyon, University Jean Monnet, Saint
Etienne, France,Department of Clinical and Exercise
Physiology, Sports Medicine Unity, University Hospital of Saint-Etienne,
Saint-Etienne, France,European Athletics Medical &
Anti-Doping Commission, European Athletics Association (EAA), Lausanne,
Switzerland
| |
Collapse
|
15
|
Bioelectrical Impedance Vector and Creatine Phosphokinase Changes Induced by a High-Intensity Training Session in Rink Hockey Players. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12020751] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
This study aimed to analyze anthropometric and whole-body/muscle-localized bioelectrical impedance vector analysis (BIVA) adaptations and their relation to creatine kinase (CK) as a biomarker of muscle damage in a group of seven male players in the maximum category of professional rink hockey. There were three checkpoint assessments in relation to a high-intensity training session: pre-session (PRE), post-session (POST), and 24 h-post-session (POST24H). The resistance, reactance, and impedance module were adjusted by height (R/h, Xc/h, and Z/h, respectively). The Wilcoxon signed-rank test was used to compare the data at baseline and follow-up, while Spearman correlation was used to explore the relationship between CK and the rest of the parameters. The results registered a decrease in body mass at POST (p = 0.03) and a reestablishment at POST24H (p = 0.02). Whole-body BIVA registered a significant increase in R/h between PRE–to–POST (p = 0.02) and returned to baseline values at POST24H (p = 0.02), which was expected since this parameter is related to hydration processes. Muscle-localized BIVA in the rectus femoris muscle showed an increase in both Xc/h and phase angle in POST (p = 0.04 and p = 0.03, respectively) and a decrease in Xc/h at POST24H (p = 0.02). CK correlated with R/h in the rectus femoris at all the checkpoints (PRE–to–POST: r = 0.75, p = 0.05; PRE–to–POST24H: r = 0.81, p = 0.03; POST–to–POST24H: r = 0.82, p = 0.02). Our results indicate that BIVA is a sensitive methodology to assess general and muscle-localized hydration induced by a high-intensity training session in rink hockey players. A correlation between BIVA and CK was also reported.
Collapse
|
16
|
Campa F, Bongiovanni T, Trecroci A, Rossi A, Greco G, Pasta G, Coratella G. Effects of the COVID-19 Lockdown on Body Composition and Bioelectrical Phase Angle in Serie A Soccer Players: A Comparison of Two Consecutive Seasons. BIOLOGY 2021; 10:biology10111175. [PMID: 34827168 PMCID: PMC8614814 DOI: 10.3390/biology10111175] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 11/08/2021] [Accepted: 11/11/2021] [Indexed: 02/05/2023]
Abstract
Simple Summary In 2020, the first Italian soccer league (Serie A) was canceled due to the COVID-19 pandemic. Consequently, a detraining process was triggered in soccer players, leading coaches and sports scientists to implement alternative training strategies to prevent a remodeling in body composition. This study tested the hypothesis that male elite soccer players, when confined to their home during the coronavirus disease 2019 pandemic, will display unfavorable trends in bioelectrical and body composition parameters. The results of the present study showed that reduction in phase angle and muscle mass occurred in soccer players during the coronavirus disease 2019 pandemic lockdown. Recognizing these adverse effects of a detraining period is critical in avoiding adverse effects on body composition in soccer players. In addition, the bioelectrical phase angle has been identified as a valid predictor of muscle mass changes during the competitive soccer season. Considerably, the phase angle represents a parameter that can be measured directly through bioelectrical impedance analysis, and it is independent of predictive equations such as those that quantify muscle mass. Abstract The present study compared changes in body composition during the COVID-19-associated lockdown with the same period of the following season in elite soccer players. Fifteen elite male soccer players (30.5 ± 3.6 years.) underwent a bioelectrical impedance analysis (BIA) before (end of February) and after (end of May) the lockdown, which occurred during the 2019/2020 season, and at the same period during the following competitive season in 2020/2021, when restrictions were lifted. Fat and muscle mass were estimated using predictive equations, while phase angle (PhA) and bioelectrical impedance vector analysis (BIVA) patterns were directly measured. After lockdown, fat mass remained unchanged (p > 0.05), while muscle mass (95%CI = −1.12/−0.64; ES = −2.04) and PhA (95%CI = 0.51/−0.24, ES = −1.56) decreased. A rightward displacement of the BIVA vector was also found (p < 0.001, ES = 1.50). After the same period during the regular season, FM% and muscle mass did not change (p > 0.05), while the PhA increased (95%CI = 0.01/0.22; ES = 0.63). A leftward vector displacement (p < 0.001, ES = 1.05) was also observed. The changes in muscle mass correlated with changes in PhA (“lockdown” season 2019/2020: ß = −1.128, p = 0.011; “regular” season 2020/21: ß = 1.963, p = 0.011). In conclusion, coaches and strength conditioners should monitor muscle mass in soccer players during detraining periods as this parameter appears to be mainly affected by changes in training plans.
Collapse
Affiliation(s)
- Francesco Campa
- Department for Life Quality Studies, University of Bologna, 47921 Rimini, Italy;
| | - Tindaro Bongiovanni
- Department of Biomedical Sciences for Health, University of Study of Milano, 20133 Milano, Italy; (T.B.); (A.T.); (G.C.)
- Department of Health, Nutrition and Exercise Physiology, Parma Calcio 1913, 43100 Parma, Italy
| | - Athos Trecroci
- Department of Biomedical Sciences for Health, University of Study of Milano, 20133 Milano, Italy; (T.B.); (A.T.); (G.C.)
| | - Alessio Rossi
- Department of Computer Science, University of Pisa, 56126 Pisa, Italy;
| | - Gianpiero Greco
- Department of Basic Medical Sciences, Neuroscience and Sense Organs, University of Study of Bari, 70121 Bari, Italy
- Correspondence:
| | - Giulio Pasta
- Medical Department, Parma Calcio 1913, 43100 Parma, Italy;
| | - Giuseppe Coratella
- Department of Biomedical Sciences for Health, University of Study of Milano, 20133 Milano, Italy; (T.B.); (A.T.); (G.C.)
| |
Collapse
|
17
|
Cebrián-Ponce Á, Irurtia A, Carrasco-Marginet M, Saco-Ledo G, Girabent-Farrés M, Castizo-Olier J. Electrical Impedance Myography in Health and Physical Exercise: A Systematic Review and Future Perspectives. Front Physiol 2021; 12:740877. [PMID: 34594243 PMCID: PMC8476966 DOI: 10.3389/fphys.2021.740877] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 08/19/2021] [Indexed: 12/25/2022] Open
Abstract
Background: Electrical impedance myography (EIM) is a non-invasive method that provides information about muscle health and changes that occur within it. EIM is based on the analysis of three impedance variables: resistance, reactance, and the phase angle. This systematic review of the literature provides a deeper insight into the scope and range of applications of EIM in health and physical exercise. The main goal of this work was to systematically review the studies on the applications of EIM in health and physical exercise in order to summarize the current knowledge on this method and outline future perspectives in this growing area, including a proposal for a research agenda. Furthermore, some basic assessment principles are provided. Methods: Systematic literature searches on PubMed, Scopus, SPORTDiscus and Web of Science up to September 2020 were conducted on any empirical investigations using localized bioimpedance devices to perform EIM within health and physical exercise contexts. The search included healthy individuals, elite soccer players with skeletal muscle injury, and subjects with primary sarcopenia. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist was used to develop the systematic review protocol. The quality and risk of bias of the studies included were assessed with the AQUA tool. Results: Nineteen eligible original articles were included in this review, which were separated into three tables according to the nature of the study. The first table includes six studies on the bioelectrical characterization of muscle. The second table includes five studies analyzing muscle changes in injured elite soccer players. The third table includes studies on the short-, medium-, and long-term bioelectrical adaptations to physical exercise. Conclusions: EIM has been used for the evaluation of the muscle condition in the clinical field over the last few years, especially in different neuromuscular diseases. It can also play an important role in other contexts as an alternative to complex and expensive methods such as magnetic resonance imaging. However, further research is needed. The main step in establishing EIM as a valid tool in the scientific field is to standardize the protocol for performing impedance assessments.
Collapse
Affiliation(s)
- Álex Cebrián-Ponce
- Barcelona Sports Sciences Research Group, Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona (UB), Barcelona, Spain
| | - Alfredo Irurtia
- Barcelona Sports Sciences Research Group, Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Carrasco-Marginet
- Barcelona Sports Sciences Research Group, Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona (UB), Barcelona, Spain
| | - Gonzalo Saco-Ledo
- Bioenergy and Motion Analysis Laboratory, National Research Center on Human Evolution (CENIEH), Burgos, Spain
| | | | | |
Collapse
|
18
|
Analysis of localized bioimpedance from healthy young adults during activities of the vocal folds using Cole-impedance model representation. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
19
|
Abstract
The body composition phenotype of an athlete displays the complex interaction among genotype, physiological and metabolic demands of a sport, diet, and physical training. Observational studies dominate the literature and describe the sport-specific physique characteristics (size, shape, and composition) of adult athletes by gender and levels of competition. Limited data reveal how body composition measurements can benefit an athlete. Thus, the objective is to identify purposeful measurements of body composition, notably fat and lean muscle masses, and determine their impact on the health and performance of athletes. Areas of interest include relationships among total and regional body composition measurements, muscle function, sport-specific performance, risk of injury, return to sport after injury, and identification of activity-induced fluid shifts. Discussion includes the application of specific uses of dual X-ray absorptiometry and bioelectrical impedance including an emphasis on the need to minimize measurement errors and standardize protocols, and highlights opportunities for future research. This focus on functional body composition can benefit the health and optimize the performance of an athlete.
Collapse
Affiliation(s)
- Henry Lukaski
- Department of Kinesiology and Public Health Education, Hyslop Sports Center, University of North Dakota, Grand Forks, United States
| | | |
Collapse
|
20
|
Assessment of Body Composition in Athletes: A Narrative Review of Available Methods with Special Reference to Quantitative and Qualitative Bioimpedance Analysis. Nutrients 2021; 13:nu13051620. [PMID: 34065984 PMCID: PMC8150618 DOI: 10.3390/nu13051620] [Citation(s) in RCA: 121] [Impact Index Per Article: 40.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 04/29/2021] [Accepted: 05/11/2021] [Indexed: 01/09/2023] Open
Abstract
Body composition is acknowledged as a determinant of athletic health and performance. Its assessment is crucial in evaluating the efficiency of a diet or aspects related to the nutritional status of the athlete. Despite the methods traditionally used to assess body composition, bioelectric impedance analysis (BIA) and bioelectric impedance vector analysis (BIVA) have recently gained attention in sports, as well as in a research context. Only until recently have specific regression equations and reference tolerance ellipses for athletes become available, while specific recommendations for measurement procedures still remain scarce. Therefore, the present narrative review summarizes the current literature regarding body composition analysis, with a special focus on BIA and BIVA. The use of specific technologies and sampling frequencies is described, and recommendations for the assessment of body composition in athletes are provided. Additionally, the estimation of body composition parameters (i.e., quantitative analysis) and the interpretation of the raw bioelectrical data (i.e., qualitative analysis) are examined, highlighting the innovations now available in athletes. Lastly, it should be noted that, up until 2020, the use of BIA and BIVA in athletes failed to provide accurate results due to unspecific equations and references; however, new perspectives are now unfolding for researchers and practitioners. In light of this, BIA and especially BIVA can be utilized to monitor the nutritional status and the seasonal changes in body composition in athletes, as well as provide accurate within- and between-athlete comparisons.
Collapse
|
21
|
Localized Bioimpedance Measurements with the MAX3000x Integrated Circuit: Characterization and Demonstration. SENSORS 2021; 21:s21093013. [PMID: 33923037 PMCID: PMC8123364 DOI: 10.3390/s21093013] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 04/15/2021] [Accepted: 04/20/2021] [Indexed: 01/24/2023]
Abstract
The commercial availability of integrated circuits with bioimpedance sensing functionality is advancing the opportunity for practical wearable systems that monitor the electrical impedance properties of tissues to identify physiological features in support of health-focused applications. This technical note characterizes the performance of the MAX3000x (resistance/reactance accuracy, power modes, filtering, gains) and is available for on-board processing (electrode detection) for localized bioimpedance measurements. Measurements of discrete impedances that are representative of localized tissue bioimpedance support that this IC has a relative error of <10% for the resistance component of complex impedance measurements, but can also measure relative alterations in the 250 mΩ range. The application of the MAX3000x for monitoring localized bicep tissues during activity is presented to highlight its functionality, as well as its limitations, for multi-frequency measurements. This device is a very-small-form-factor single-chip solution for measuring multi-frequency bioimpedance with significant on-board processing with potential for wearable applications.
Collapse
|
22
|
Logothetis I, Gil I, Wang X, Razal J. Comparison of silver-plated nylon (Ag/PA66) e-textile and Ag/AgCl electrodes for bioelectrical impedance analysis (BIA). Biomed Phys Eng Express 2021; 7. [PMID: 33770764 DOI: 10.1088/2057-1976/abf2a0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/26/2021] [Indexed: 11/12/2022]
Abstract
Recently, researchers have adapted Bioelectrical Impedance Analysis (BIA) as a new approach to objectively monitor wounds. They have indicated various BIA parameters associated to specific wound types can be linked to wound healing through trend analysis relative to time. However, these studies are conducted using wet electrodes which have been identified as possessing several shortcomings, such as unstable measurements. Thus, the adaption of e-textile electrodes has become an area of interest in measuring biosignals. E-textile electrodes are known to possess a significantly large polarization impedance (Zp) that potentially influences these biosignal measurements. In this study we aim to identify the suitability of e-textile electrodes to monitor wounds using BIA methodologies. By adapting suggested methodologies conducted in-vivo from previous studies, we used an ex-vivo model to observe the behaviour of e-textile electrodes relative to time. This was compared to common clinical wet electrodes, specifically Ag/AgCl. The objective of this study was to identify the BIA parameters that can be used to monitor wounds with e-textile electrodes. By analysing the BIA parameters relative to time, we observed the influence ofZpon these parameters.
Collapse
Affiliation(s)
- Irini Logothetis
- Institute of Frontier Materials, Deakin University, Geelong, Australia
| | - Ignacio Gil
- Department of Electronic Engineering, Universitat Politecnica de Catalunya, Terrassa (Barcelona), Spain
| | - Xungai Wang
- Institute of Frontier Materials, Deakin University, Geelong, Australia
| | - Joselito Razal
- Institute of Frontier Materials, Deakin University, Geelong, Australia
| |
Collapse
|
23
|
Honorato RDC, Ferraz ASM, Kassiano W, Carvalho DP, Ceccatto VM. Test-retest reliability of electrical impedance myography in hamstrings of healthy young men. J Electromyogr Kinesiol 2021; 56:102511. [PMID: 33454538 DOI: 10.1016/j.jelekin.2020.102511] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/22/2020] [Accepted: 12/30/2020] [Indexed: 11/16/2022] Open
Abstract
Several techniques are available to assess muscle tissue status, including electrical impedance myography (EIM). Despite being used in the assessment of neuromuscular status in injury and response to exercise, reliability data for hamstrings muscles are limited. Therefore, this study aimed to determine the test-retest reliability of EIM components on hamstrings. Twenty-one healthy males (25.3 ± 3.4 years; 173 ± 6.7 cm; and 79.7 ± 15.9 kg) volunteered for this study. Subjects completed two visits, separated by seven days to collect EIM components (resistance, reactance, impedance, and phase angle) in the longitudinal and transversal axis of hamstrings in both thighs, using a bioimpedance device and Ag/AgCL adhesive contact electrodes. The electrode arrangement was in the muscular belly, half the distance between origin and insertion of the hamstrings. Reliability was determined by the intraclass correlation coefficient (ICC), minimal detectable change (MDC), and Bland-Altman plots. We observed high to excellent reliability (ICC > 0.85) between all EIM components, except for reactance with MDC ranged from 2.0 to 10.8 and the mean bias in Bland-Altman plots ranged from -0.02 to 2.48 (95% limits of agreement from -9.98 to 11.20). From our findings, the hamstrings assessment using EIM technique is reliable to assess muscle tissue; therefore, it enables the evaluation of changes/adaptations in clinical and applied contexts.
Collapse
Affiliation(s)
- Renêe de Caldas Honorato
- Sports Department, Pará State University, Belém, Brazil; Northeast Biotechnology Network, Postgraduate Program in Biotechnology, Ceará State University, Fortaleza, Brazil.
| | - Alex Soares Marreiros Ferraz
- Biotechnology and Exercise Biology Research Laboratory, Institute of Physical Education and Sports, Federal University of Ceará, Fortaleza, Brazil
| | - Witalo Kassiano
- Metabolism, Nutrition and Exercise Laboratory, Physical Education and Sport Center, Londrina State University, Londrina, Brazil.
| | - Denise Pires Carvalho
- Endocrine Physiology Doris Rosenthal Research Laboratory, Institute of Biophysical Carlos Chagas Filho, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Vânia Marilande Ceccatto
- Northeast Biotechnology Network, Postgraduate Program in Biotechnology, Ceará State University, Fortaleza, Brazil; Biochemistry and Gene Expression Research Laboratory, Superior Institute of Biomedical Science, Ceará State University, Fortaleza, Brazil
| |
Collapse
|
24
|
Oubre B, Daneault JF, Boyer K, Kim JH, Jasim M, Bonato P, Lee SI. A Simple Low-Cost Wearable Sensor for Long-Term Ambulatory Monitoring of Knee Joint Kinematics. IEEE Trans Biomed Eng 2020; 67:3483-3490. [PMID: 32324536 PMCID: PMC7709863 DOI: 10.1109/tbme.2020.2988438] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
OBJECTIVE Accurate monitoring of joint kinematics in individuals with neuromuscular and musculoskeletal disorders within ambulatory settings could provide important information about changes in disease status and the effectiveness of rehabilitation programs and/or pharmacological treatments. This paper introduces a reliable, power efficient, and low-cost wearable system designed for the long-term monitoring of joint kinematics in ambulatory settings. METHODS Seventeen healthy subjects wore a retractable string sensor, fixed to two anchor points on the opposing segments of the knee joint, while walking at three different self-selected speeds. Joint angles were estimated from calibrated sensor values and their derivatives in a leave-one-subject-out cross validation manner using a random forest algorithm. RESULTS The proposed system estimated knee flexion/extension angles with a root mean square error (RMSE) of 5.0°±1.0° across the study subjects upon removal of a single outlier subject. The outlier was likely a result of sensor miscalibration. CONCLUSION The proposed wearable device can accurately estimate knee flexion/extension angles during locomotion at various walking speeds. SIGNIFICANCE We believe that our novel wearable technology has great potential to enable joint kinematic monitoring in ambulatory settings and thus provide clinicians with an opportunity to closely monitor joint recovery, develop optimal, personalized rehabilitation programs, and ultimately maximize therapeutic outcomes.
Collapse
|
25
|
Campa F, Bongiovanni T, Matias CN, Genovesi F, Trecroci A, Rossi A, Iaia FM, Alberti G, Pasta G, Toselli S. A New Strategy to Integrate Heath-Carter Somatotype Assessment with Bioelectrical Impedance Analysis in Elite Soccer Player. Sports (Basel) 2020; 8:E142. [PMID: 33121135 PMCID: PMC7694105 DOI: 10.3390/sports8110142] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 10/23/2020] [Accepted: 10/24/2020] [Indexed: 01/11/2023] Open
Abstract
Easy-to-apply and quick methods for evaluate body composition are often preferred when assessing soccer teams. This study aimed to develop new equations for the somatotype quantification that would reduce the anthropometric measurements required by the Heath and Carter method, integrating the somatotype assessment to the bioelectrical impedance analysis (BIA). One hundred and seventy-six male elite soccer players (age 26.9 ± 4.5 years), registered in the Italian first division (Serie A), underwent anthropometric measurements and BIA. Endomorphy, mesomorphy, and ectomorphy were obtained according to the Heath and Carter method, while fat mass (FM) and fat free mass (FFM) estimated using a BIA-derived equation specific for athletes. The participants were randomly split into development (n = 117) and validation groups (n = 59, 1/3 of sample). The developed models including resistance2/stature, FM%, FFM, contracted arm and calf circumference, triceps, and supraspinal skinfolds had high predictive ability for endomorphy (R2 = 0.83, Standard Error of Estimate (SEE) = 0.16) mesomorphy (R2 = 0.80, SEE = 0.36), and ectomorphy (endomorphy (R2 = 0.87, SEE = 0.22). Cross validation revealed R2 of 0.80, 0.84, 0.87 for endomorphy, mesomorphy, and ectomorphy, respectively. The proposed strategy allows the integration of somatotype assessment to BIA in soccer players, reducing the number of instruments and measurements required by the Heath and Carter approach.
Collapse
Affiliation(s)
- Francesco Campa
- Department for Life Quality Studies, University of Bologna, 47921 Rimini, Italy;
| | - Tindaro Bongiovanni
- Department of Health, Performance and Recovery, Parma Calcio 1913, 40121 Parma, Italy
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20129 Milano, Italy; (A.T.); (F.M.I.); (G.A.)
| | - Catarina N. Matias
- Faculdade de Educação Física e Desporto, Universidade Lusófona, 1749-024 Lisboa, Portugal;
- CIPER—Interdisciplinary Center for the Study of Human Performance, Faculty Human Kinetics, University of Lisbon, 1495-751 Lisboa, Portugal
- Bioperformance & Nutrition Research Unit, Ingrediente Métrico S.A., 2740-262 Lisbon, Portugal
| | - Federico Genovesi
- Medical Department Manchester City Football Club, Manchester 03101, UK;
| | - Athos Trecroci
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20129 Milano, Italy; (A.T.); (F.M.I.); (G.A.)
| | - Alessio Rossi
- Department of Computer Science, University of Pisa, 56121 Pisa, Italy;
| | - F. Marcello Iaia
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20129 Milano, Italy; (A.T.); (F.M.I.); (G.A.)
| | - Giampietro Alberti
- Department of Biomedical Sciences for Health, Università degli Studi di Milano, 20129 Milano, Italy; (A.T.); (F.M.I.); (G.A.)
| | - Giulio Pasta
- Medical Department Parma Calcio 1913, 40121 Parma, Italy;
| | - Stefania Toselli
- Department of Biomedical and Neuromotor Sciences, University of Bologna, 40126 Bologna, Italy;
| |
Collapse
|
26
|
Fu B, Freeborn TJ. Cole-impedance parameters representing biceps tissue bioimpedance in healthy adults and their alterations following eccentric exercise. J Adv Res 2020; 25:285-293. [PMID: 32922994 PMCID: PMC7474209 DOI: 10.1016/j.jare.2020.05.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Revised: 05/13/2020] [Accepted: 05/14/2020] [Indexed: 12/14/2022] Open
Abstract
The purpose of this study is to identify if participation in an eccentric exercise protocol altered the Cole-impedance model parameters that represent localized bicep tissue bioimpedance. This supports continued efforts to identify which features of tissue bioimpedance may be effective markers to non-invasively identify skeletal muscle damage. Here, the Cole-impedance model parameters that best fit the localized electrical impedance of exercised (using an eccentric stimulus) and unexercised biceps of 6 participants (collected before, immediately after and at 24 h, 48 h, 72 h and 96 h) are determined using a numerical optimization technique. Statistical tests comparing the pre-exercise and post-exercise model parameters report significant decreases in R ∞ and R 1 with significant increases in C at 72 h and 96 h post-exercise for exercised biceps (aligning with noted periods of peak swelling). These changes in R ∞ , R 1 , and C were not observed in the unexercised biceps. These results support that the C parameter of the Cole-impedance model fit to bioimpedance data may be a suitable marker for identifying skeletal muscle damage.
Collapse
Affiliation(s)
- Bo Fu
- Dept. Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, USA
| | - Todd J Freeborn
- Dept. Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, USA
| |
Collapse
|
27
|
Nescolarde L, Terricabras J, Mechó S, Rodas G, Yanguas J. Differentiation Between Tendinous, Myotendinous and Myofascial Injuries by L-BIA in Professional Football Players. Front Physiol 2020; 11:574124. [PMID: 33013488 PMCID: PMC7500181 DOI: 10.3389/fphys.2020.574124] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 08/14/2020] [Indexed: 12/27/2022] Open
Abstract
Purpose To differentiate by localized bioimpedance (L-BIA) measurements 24 h after injury, between tendinous, myotendinous junction (MTJ), and myofascial junction (MFJ) injuries, previously diagnosed by MRI exam. To evaluate by L-BIA, the severity of MTJ injuries graded from 1 to 3, and to determine the relationship between days to return to play (RTP) and L-BIA measurements. Methods 3T MRI and tetra polar L-BIA was used to analyzed 37 muscle injuries 24 h after injury in 32 male professional football players, (23.5 ± 1.5 kg m–2; 1.8 ± 0.1 m; 20–30 year.) between the 2016–2017 and 2017–2018 seasons. Muscle injuries were classified by The British Athletics Muscle Injury Classification (BAMIC). Percentage difference of L-BIA parameters [resistance (R), reactance (Xc), and phase angle (PA)] of the injured side were calculated considering contralateral non-injured side as the reference value. Results According to BAMIC classification and by MRI exam, we found tendinous (n = 4), MTJ (n = 26), and MFJ (n = 7) muscle injuries. In addition, MTJ injuries were grouped according to the severity of injury in grade 1 (n = 11), grade 2 (n = 8), and grade 3 (n = 7). Significant decrease (P < 0.01) was found in the L-BIA parameters R, Xc, and PA, in both MTJ and MFJ as well as in the different grades of MTJ injuries. In particular, in Xc (P < 0.001), which is related to muscle cell disruption. Regarding days to RTP, there was statistical significance among the three different grades of MTJ injuries (P < 0.001), especially when grade 1 was compared to grade 3 and grade 2 compared to 3. Conclusion L-BIA is a complementary method to imaging diagnostic techniques, such as MRI and US, to quantify MTJ and MFJ injuries. In addition, the increase in the severity of the MTJ injury resulted in higher changes of the Xc parameter and longer time to RTP.
Collapse
Affiliation(s)
- Lexa Nescolarde
- Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
| | - Joaquim Terricabras
- Medical Department, Futbol Club Barcelona, FIFA Medical Center of Excelence, Barcelona, Spain.,Department of Surgery, Faculty of Medicine, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Sandra Mechó
- Medical Department, Futbol Club Barcelona, FIFA Medical Center of Excelence, Barcelona, Spain.,Department of Radiology, SCIAS-Hospital de Barcelona, Barcelona, Spain
| | - Gil Rodas
- Medical Department, Futbol Club Barcelona, FIFA Medical Center of Excelence, Barcelona, Spain
| | - Javier Yanguas
- Medical Department, Futbol Club Barcelona, FIFA Medical Center of Excelence, Barcelona, Spain
| |
Collapse
|
28
|
Martinez-Gonzalez M, Montilla-Herrador J, García-Vidal JA, Escolar-Reina P, Gacto-Sánchez M, Medina-Mirapeix F. Intra- and inter-rater reliability of electrical impedance myography using adhesive electrodes in healthy volunteers. J Electromyogr Kinesiol 2020; 55:102456. [PMID: 32905888 DOI: 10.1016/j.jelekin.2020.102456] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 07/31/2020] [Accepted: 08/01/2020] [Indexed: 12/14/2022] Open
Abstract
In spite of the growing use of the electrical impedance myography (EIM) measures for clinical assessment and follow-up of diseased muscle tissue, reliability studies are scarce. We evaluate the reliability of the (EIM) technique using four adhesive electrodes over the muscle of interest. Intra- and inter-rater reliability was studied within the same session and between sessions. Thirty-one healthy and volunteer subjects aged between 20 and 26 years were recruited. Phase angle, reactance and resistance were assessed for each EIM measurement. Intraclass correlation coefficient (ICC) was used to determine the relative reliability. Absolute reliability was expressed as the standard error of measurement and the minimum detectable change. Relative reliability within the same session and between sessions for the EIM technique was excellent (ICCs > 0.9) concerning both intra- and inter-rater reliability, except for the component reactance. The absolute reliability was very high for the three EIM components. EIM measures using four adhesive electrodes over the area of interest is a reliable technique to assess muscle tissue status. This study confirms that these measurement results barely vary depending on the examiner and the moment. The present study also confirms phase angle as the least affected EIM component by examiner and evaluation moment.
Collapse
Affiliation(s)
- Mariano Martinez-Gonzalez
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain.
| | - Joaquina Montilla-Herrador
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| | - Jose A García-Vidal
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| | - Pilar Escolar-Reina
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| | - Mariano Gacto-Sánchez
- Department of Physical Therapy, EUSES University School, University of Girona, Spain
| | - Francesc Medina-Mirapeix
- Instituto Murciano de Investigación Biosanitaria Virgen de la Arrixaca (IMIB-Arrixaca), Murcia, Spain; Department of Physical Therapy, University of Murcia, Murcia, Spain
| |
Collapse
|
29
|
Somatotype and Bioimpedance Vector Analysis: A New Target Zone for Male Athletes. SUSTAINABILITY 2020. [DOI: 10.3390/su12114365] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Background: Bioelectrical impedance vector analysis (BIVA) is a body composition assessment method based on the interpretation of the raw bioimpedance parameters. While it was initially proposed in clinical settings, its use in the sports field has grown considerably. The aim of this study was: (i) to explore the role of somatotype on BIVA patterns and (ii) to propose a new target zone to improve BIVA analysis in ball games athletes. Methods: One hundred and sixty-four male volleyball, soccer, and rugby players (age 26.2 ± 4.4 yrs; body mass index (BMI) 25.4 ± 2.4 kg/m2) were included in this study. Somatotype and BIVA were measured from anthropometric and bioelectrical data, respectively. Results: Forty-six athletes were classified with an endomorphic mesomorphic somatotype, 26 showed a balanced mesomorphy, 55 were ectomorphic mesomorph, 10 resulted as mesomorph ectomorphs, 13 with a mesomorphic ectomorph somatotype, and in 14 athletes a balanced ectomorphy was assessed. The results of the Hotelling’s T2 test showed significant differences in BIVA patterns for the endomorphic mesomorph group (p < 0.001) in comparison with all the other groups, while mesomorphic balanced athletes presented a more inclined vector compared to the athletes with a balanced ectomorphy (p < 0.003). In addition, the endomorphic mesomorph group showed a greater BMI (p < 0.001) with respect to the athletes grouped in the other somatotype categories. Discriminant analysis revealed two significant functions (p < 0.001). The first discriminant function primarily represented differences based on the bioelectrical standardized resistance parameter (R/H) measure, while the second function reflected differences based on the bioelectrical standardized reactance parameter (Xc/H). Conclusions: Athletes presenting a higher endomorphic component have a lower vector, whereas those with a larger mesomorphic component display higher vector inclinations on the R-Xc graph. We propose a new target zone to improve the interpretation of BIVA analysis in athletes engaged in team sports.
Collapse
|
30
|
Pingel J, Harrison A, Von Walden F, Hjalmarsson E, Bartels EM. Multi-frequency bioimpedance: a non-invasive tool for muscle-health assessment of adults with cerebral palsy. J Muscle Res Cell Motil 2020; 41:211-219. [PMID: 32221759 DOI: 10.1007/s10974-020-09579-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 03/14/2020] [Indexed: 12/13/2022]
Abstract
Muscle contracture development is a major complication for individuals with cerebral palsy (CP) and has lifelong implications. In order to recognize contracture development early and to follow up on preventive interventions aimed at muscle health development, non-invasive, and easy to use methods are needed. The aim of the present study was to assess whether multi-frequency Bioimpedance (mfBIA) can be used to detect differences between skeletal muscle of individuals with CP and healthy controls. The mfBIA technique was applied to the medial gastrocnemius muscle of n = 24 adults with CP and n = 20 healthy controls of both genders. The phase angle (PA) and the centre frequency (fc) were significantly lower in individuals with CP when compared to controls; PA: - 25% for women and - 31.8% for men (P < 0.0001); fc: - 5.6% for women and - 5.2% for men (P < 0.009). The reactance (Xc) and the extracellular resistance (Re) of skeletal muscle from individuals with CP were significantly higher when compared to controls; Xc: + 9.9% for women and + 28.9% for men (P < 0.0001); Re: + 39.7% for women and + 91.2% for men (P < 0.0001). The present study shows that several mfBIA parameters differ significantly between individuals with CP and healthy controls. Furthermore, these changes correlated significantly with the severity of CP, as assessed using the GMFCS scale. The present data indicate that mfBIA shows promise in terms of being a useful diagnostic tool, capable of characterizing muscle health and its development in individuals with cerebral palsy.
Collapse
Affiliation(s)
- Jessica Pingel
- Department of Neuroscience, Faculty of Health & Medical Sciences, University of Copenhagen, Blegdamsvej 3.33.3.50, 2200, Copenhagen N, Denmark.
| | - Adrian Harrison
- PAS, Physiology, Faculty of Health & Medical Sciences, University of Copenhagen, Frederiksberg C, Denmark
| | - Ferdinand Von Walden
- Division of Pediatric Neurology, Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Emma Hjalmarsson
- Division of Pediatric Neurology, Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
- Functional Area Occupational Therapy & Physiotherapy, Karolinska University Hospital, Stockholm, Sweden
| | - Else Marie Bartels
- Department of Neurology & The Parker Institute, Copenhagen University Hospital, Bispebjerg and Frederiksberg, Copenhagen, Denmark
| |
Collapse
|
31
|
Shiose K, Tanabe Y, Ohnishi T, Takahashi H. Effect of regional muscle damage and inflammation following eccentric exercise on electrical resistance and the body composition assessment using bioimpedance spectroscopy. J Physiol Sci 2019; 69:895-901. [PMID: 31388975 PMCID: PMC10717188 DOI: 10.1007/s12576-019-00702-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Accepted: 07/30/2019] [Indexed: 12/12/2022]
Abstract
We investigated the effect of muscle damage and inflammation on electrical resistance and the body composition assessment by using bioimpedance spectroscopy (BIS). Twenty-two subjects completed 30 repetitions of maximal eccentric contractions of the elbow flexors with one arm. Whole-body resistance of extracellular and intracellular components (Re and Ri, respectively) on the exercised and non-exercised sides were measured using BIS. Body composition was calculated from both sides of resistance at baseline and 96 h after exercise. Re decreased only on the exercised side at 96 h after exercise (P < 0.05). Fat-free and fat mass values estimated from resistance on the exercised side were altered by 3.1% and - 15.6%, respectively, at 96 h after exercise (P < 0.05); those estimated from the non-exercised side were unaltered. Eccentric exercise-induced muscle damage and inflammation reduce Re and induce non-negligible estimation error in the body composition assessment using BIS.
Collapse
Affiliation(s)
- Keisuke Shiose
- Faculty of Education, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki, 889-2192, Japan.
- Fukuoka University Institute for Physical Activity, 8-19-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan.
| | - Yoko Tanabe
- Japan Institute of Sports Sciences, 3-15-1 Nishigaoka, Kita-ku, Tokyo, 115-0056, Japan
| | - Takahiro Ohnishi
- Japan Institute of Sports Sciences, 3-15-1 Nishigaoka, Kita-ku, Tokyo, 115-0056, Japan
| | - Hideyuki Takahashi
- Japan Institute of Sports Sciences, 3-15-1 Nishigaoka, Kita-ku, Tokyo, 115-0056, Japan
| |
Collapse
|
32
|
Rutkove SB, Sanchez B. Electrical Impedance Methods in Neuromuscular Assessment: An Overview. Cold Spring Harb Perspect Med 2019; 9:cshperspect.a034405. [PMID: 30291145 DOI: 10.1101/cshperspect.a034405] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Electrical impedance methods have been used as evaluation tools in biological and medical science for well over 100 years. However, only recently have these techniques been applied specifically to the evaluation of conditions affecting nerve and muscle. This specific application, termed electrical impedance myography (EIM), is finding wide application as it can provide a quantitative index of muscle condition that can assist with diagnosis, track disease progression, and assess the beneficial impact of therapy. Using noninvasive surface methods, EIM has been studied in a number of conditions ranging from amyotrophic lateral sclerosis to muscular dystrophy to disuse atrophy. Data support that the technique is sensitive to disease status and can offer the possibility of performing clinical trials with fewer subjects than would otherwise be possible. Recent advances in the field include improved approaches for using EIM as a "virtual biopsy" and the development of combined needle impedance-electromyography technology.
Collapse
Affiliation(s)
- Seward B Rutkove
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts 02215
| | - Benjamin Sanchez
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts 02215
| |
Collapse
|
33
|
Mabrouk S, Hersek S, Jeong HK, Whittingslow D, Ganti VG, Wolkoff P, Inan OT. Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy. IEEE Trans Biomed Eng 2019; 67:1019-1029. [PMID: 31295102 DOI: 10.1109/tbme.2019.2927807] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS). METHODS We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema. This technique addresses many of the major challenges in longitudinal BIS-based edema assessment, including day-to-day variability in electrode placement, positional/postural variability, and intersubject variability. RESULTS We first evaluated the hardware in bench-top testing, and determined the error of the bioimpedance measurements to be 0.4 Ω for the real components and 0.54 Ω for the imaginary components with a resolution of 0.2 Ω. We then validated the hardware and differential measurement technique in: 1) an ex vivo, fresh-frozen, cadaveric limb model, and 2) a cohort of 11 human subjects for proof of concept (eight healthy controls and five subjects with recently acquired acute unilateral ankle injury). CONCLUSION The hardware design, with novel calibration methodology, and differential measurement technique can potentially enable long-term quantification of ankle edema throughout the course of rehabilitation following acute ankle injuries. SIGNIFICANCE This could lead to better-informed decision making regarding readiness to return to activities and/or tailoring of rehabilitation activities to an individual's changing needs.
Collapse
|
34
|
Bartels EM, Andersen EL, Olsen JK, Kristensen LE, Bliddal H, Danneskiold‐Samsøe B, Harrison AP. Muscle assessment using multi-frequency bioimpedance in a healthy Danish population aged 20-69 years: a powerful non-invasive tool in sports and in the clinic. Physiol Rep 2019; 7:e14109. [PMID: 31197976 PMCID: PMC6565800 DOI: 10.14814/phy2.14109] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 04/29/2019] [Accepted: 05/08/2019] [Indexed: 12/17/2022] Open
Abstract
The condition of active muscles determines an individual's ability to carry out daily activities and has implications for an athlete's performance. Multi-frequency bioimpedance (mfBIA) is a non-invasive, well-known, validated, and much used method to assess muscle condition. However, it is rarely used to its full potential. Our aim was to apply mfBIA fully in the assessment of an adult healthy population, to compare muscle condition in different functional rested muscle groups, with age, and between men and women, and establish a control data set. Fifty healthy subjects (25 men/25 women) aged 20-69 years, participated. mfBIA measurements at a frequency range of 4-1000 kHz were taken from muscles of the lower and the upper extremities, the upper back, and the hand. Data were analyzed using ImpediMed software, giving Impedance, Resistance, Reactance, Phase Angle, Center Frequency, external and internal Resistance, and Membrane Capacitance. Differences between means were tested for statistical significance. A P value >0.05 was considered nonsignificant. While no difference in the mfBIA parameters was seen with age, a highly significant gender difference was seen. At rest, women's muscles cf men's showed a significantly higher center frequency and intra- and extra-cellular resistance, while the membrane capacitance was lower. A set of values for mfBIA parameters for healthy adult individuals are given for some of the main muscles which are frequently part of muscle assessment. The documented gender difference in muscle condition at rest has important implications in work situations, during physical rehabilitation and when training for competitive sports.
Collapse
Affiliation(s)
- Else Marie Bartels
- The Parker InstituteCopenhagen University HospitalBispebjerg & FrederiksbergFrederiksbergDenmark
- Department of NeurologyCopenhagen University HospitalBispebjerg & FrederiksbergCopenhagenDenmark
- Copenhagen Center for Translational ResearchCopenhagen University Hospital, Bispebjerg & FrederiksbergCopenhagenDenmark
| | - Eva Littrup Andersen
- The Parker InstituteCopenhagen University HospitalBispebjerg & FrederiksbergFrederiksbergDenmark
| | - Jack Kvistgaard Olsen
- The Parker InstituteCopenhagen University HospitalBispebjerg & FrederiksbergFrederiksbergDenmark
| | - Lars Erik Kristensen
- The Parker InstituteCopenhagen University HospitalBispebjerg & FrederiksbergFrederiksbergDenmark
- Department of Clinical MedicineFaculty of Health & Medical SciencesCopenhagen UniversityCopenhagenDenmark
| | - Henning Bliddal
- The Parker InstituteCopenhagen University HospitalBispebjerg & FrederiksbergFrederiksbergDenmark
- Department of Clinical MedicineFaculty of Health & Medical SciencesCopenhagen UniversityCopenhagenDenmark
| | - Bente Danneskiold‐Samsøe
- The Parker InstituteCopenhagen University HospitalBispebjerg & FrederiksbergFrederiksbergDenmark
- Department of Clinical MedicineFaculty of Health & Medical SciencesCopenhagen UniversityCopenhagenDenmark
| | - Adrian Paul Harrison
- Pathobiological Sciences (Physiology)Faculty of Health & Medical SciencesCopenhagen UniversityFrederiksbergDenmark
| |
Collapse
|
35
|
Freeborn TJ, Fu B. Time-course bicep tissue bio-impedance changes throughout a fatiguing exercise protocol. Med Eng Phys 2019; 69:109-115. [PMID: 31056402 DOI: 10.1016/j.medengphy.2019.04.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 03/19/2019] [Accepted: 04/09/2019] [Indexed: 12/14/2022]
Abstract
This study investigated the localized electrical-impedance changes in the biceps tissues throughout a fatiguing exercise protocol. During the protocol, 17 subjects performed 10 sets of bicep curl repetitions at either 60% or 75% of their one-repetition maximum weight until task failure. The localized tissue impedance (resistance, reactance, phase angle) was measured at 10 kHz, 50 kHz, and 100 kHz immediately after each of 10 sets for comparison against the baseline pre-fatigue measures. A trend of decreasing resistance and reactance magnitude were observed, with greater changes occurring as the protocol progressed. Statistical testing demonstrated statistically significant changes in resistance, reactance, and phase angle for both groups of participants. The significant changes in resistance were observed at earlier time-points than the reactance and phase angle changes for both groups.
Collapse
Affiliation(s)
- Todd J Freeborn
- Department of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL 35487, USA.
| | - Bo Fu
- Department of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL 35487, USA
| |
Collapse
|
36
|
Suspension syndrome: a potentially fatal vagally mediated circulatory collapse-an experimental randomized crossover trial. Eur J Appl Physiol 2019; 119:1353-1365. [PMID: 30895459 PMCID: PMC6517360 DOI: 10.1007/s00421-019-04126-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Accepted: 03/13/2019] [Indexed: 12/22/2022]
Abstract
Purpose Suspension syndrome describes a potentially life-threatening event during passive suspension on a rope. The pathophysiological mechanism is not fully understood and optimal treatment unknown. We aimed to elucidate the pathophysiology and to give treatment recommendations. Methods In this experimental, randomized crossover trial, 20 healthy volunteers were suspended in a sit harness for a maximum of 60 min, with and without prior climbing. Venous pooling was assessed by measuring the diameter of the superficial femoral vein (SFV), lower leg tissue oxygenation (StO2) and by determining localized bioelectrical impedance. Hemodynamic response was assessed by measuring heart rate, blood pressure, stroke volume, and left ventricular diameters. Signs and symptoms of pre-syncope were recorded. Results Twelve (30%) out of 40 tests were prematurely terminated due to pre-syncopal symptoms (mean 44.7 min, minimum 13.4, maximum 59.7). SFV diameter increased, StO2 and the capacitive resistance of the cells decreased indicating venous pooling. Heart rate and blood pressure did not change in participants without pre-syncope. In contrast, in participants experiencing pre-syncope, heart rate and blood pressure dropped immediately before the event. All symptoms dissolved and values returned to normal within 5 min with participants in a supine position. Conclusions Sudden pre-syncope during passive suspension in a harness was observed in 30% of the tests. Blood pools in the veins of the lower legs; however, a vagal mechanism finally leads to loss of consciousness. Time to pre-syncope is unpredictable and persons suspended on a rope should be rescued and put into a supine position as soon as possible. Electronic supplementary material The online version of this article (10.1007/s00421-019-04126-5) contains supplementary material, which is available to authorized users.
Collapse
|
37
|
Jeong IS, Lee EJ, Kim JH, Kim GH, Hwang YJ, Jeon GR. Detection of intravenous infiltration using impedance parameters in patients in a long-term care hospital. PLoS One 2019; 14:e0213585. [PMID: 30897178 PMCID: PMC6428251 DOI: 10.1371/journal.pone.0213585] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Accepted: 02/25/2019] [Indexed: 11/19/2022] Open
Abstract
This study was aimed to evaluate the changes of impedance parameters of patients who were admitted to a long-term care hospital by measuring bioelectrical impedance. The subjects were 18 patients who had infusion therapy through peripheral intravenous (IV) catheters and had at least an infiltration. The impedance parameters were measured with a multi-channel impedance measuring instrument (Vector Impedance Meter) twice; at starting IV infusion after catheter insertion and infiltration detected. As results, the resistance (R) after infiltration significantly decreased compared to the initial resistance. At 50 kHz, the resistances were 498.2±79.3 [Ω] before infiltration and 369.4±85.6 [Ω] after infiltration. The magnitude of the reactance (XC) decreased after infiltration. At 50 kHz, the measured reactance was -31.1±8.3 [Ω] before infiltration and -24.5±5.9 [Ω] after infiltration. The data points plotted in the R-XC graph shifted from the first quadrant before infiltration to third quadrant after infiltration. Our findings suggest that bioelectrical impedance is an effective method for detection of infiltration in a noninvasive and quantitative manner.
Collapse
Affiliation(s)
- Ihn Sook Jeong
- College of Nursing, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Joo Lee
- Dept, of Nursing, Dong-Eui University, Busan, South Korea
| | - Jae Hyung Kim
- Research Institute of Nursing Science, Pusan National University, Yangsan, Republic of Korea
- * E-mail:
| | - Gun Ho Kim
- Dept. of Medical Science, School of Medicine, Pusan National University, Yangsan, Republic of Korea
| | - Young Jun Hwang
- Dept. of Medical Science, School of Medicine, Pusan National University, Yangsan, Republic of Korea
| | - Gye Rok Jeon
- Dept. of Biomedical Engineering, School of Medicine, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
38
|
Martins PC, Hansen F, Silva AM, Silva DAS. Fluid distribution and cell integrity indicators evaluated by bioelectrical impedance in university athletes: comparison between team sports and individual sports. Physiol Meas 2019; 40:015004. [PMID: 30557857 DOI: 10.1088/1361-6579/aaf8cd] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To compare indicators of fluid distribution and cellular integrity in university athletes through a cross-sectional study of 167 university athletes (18-35 years) who competed in team sports and individual sports. APPROACH Bioimpedance was used to estimate total body water (TBW), intracellular water (ICW), extracellular water (ECW), ECW/ICW ratio, impedance (Z), reactance (Xc), resistance (R), phase angle, body cell mass (BCM) and ECW/BCM ratio at a frequency of 50 kHz. X-ray absorptiometry was used to determine lean soft tissue mass and body fat. As covariables, sex, age, time of practice and type of modality were obtained by questionnaire. MAIN RESULTS Individual male athletes presented higher values of ECW/ICW ratio (means difference MD = 0.006, p = 0.020) and ECW/BCM ratio (MD = 0.006, p = 0.017) than team sports male athletes. Values of Z (MD = 24.988, p = 0.009), Xc (MD = 3.327, p = 0.008) and R (MD = 24.755, p = 0.09) were higher in male athletes practicing team sports than individual sports. Female team sports athletes presented higher values of Z (MD = 32.029, p = 0.015) and R (MD = 31.987, p = 0.015) than individual female athletes. It was concluded that ECW/ICW and ECW/BCM ratios were higher in male athletes who practiced individual sports. For the Z, R, and Xc values, the athletes in team sports presented higher values. The female athletes who practiced team sports presented higher values of Z and R than did individual female athletes. SIGNIFICANCE ECW/ICW and ECW/BCM ratios were higher in male athletes who practiced individual sports. For the Z, R, and Xc values, the athletes in team sports presented higher values. The female athletes who practiced team sports presented higher values of Z and R than did individual female athletes.
Collapse
Affiliation(s)
- Priscila Custódio Martins
- Federal University of Santa Catarina, Research Center in Kinanthropometry and Human Performance, Florianópolis, Brazil. Federal University of Santa Catarina, Research Center in Kinanthropometry and Human Performance, Sports Centre, University Campus, Trindade, 88040-900 Florianópolis, Santa Catarina, Brazil. Author to whom any correspondence should be addressed
| | | | | | | |
Collapse
|
39
|
Design and Evaluation of an Electrical Bioimpedance Device Based on DIBS for Myography during Isotonic Exercises. JOURNAL OF LOW POWER ELECTRONICS AND APPLICATIONS 2018. [DOI: 10.3390/jlpea8040050] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Electrical Bioimpedance Spectroscopy (EIS) is a technique used to assess passive electrical properties of biological materials. EIS detects physiological and pathological conditions in animal tissues. Recently, the introduction of broadband excitation signals has reduced the measuring time for application techniques such as Electrical Bioimpedance Myography. Therefore, this work is aimed at proposing a prototype by using discrete interval binary sequences (DIBS), which is based on a system that holds a current source, impedance acquisition system, microcontroller and graphical user interface. Measurements between 5 Ω to 5 kΩ had impedance acquisition and phase angle errors of aproximately 2% and were lower than 3 degrees, respectively. Based on a proposed circuit, bioimpedance of the chest muscle (Pectoralis Major) was measured during isotonic exercise (push-up). As a result, our analyses have detected tiredness and fatigue. We have explored and proposed new parameters which assess such conditions, as both the maximum magnitude and tiredness coefficient. These parameters decrease exponentially with consecutive push-ups and were convergent in the majority of the sixteen days of measurement.
Collapse
|
40
|
Physiology of exercise and phase angle: another look at BIA. Eur J Clin Nutr 2018; 72:1323-1327. [DOI: 10.1038/s41430-018-0215-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 05/09/2018] [Indexed: 11/08/2022]
|
41
|
Mullie L, Obrand A, Bendayan M, Trnkus A, Ouimet M, Moss E, Chen‐Tournoux A, Rudski LG, Afilalo J. Phase Angle as a Biomarker for Frailty and Postoperative Mortality: The BICS Study. J Am Heart Assoc 2018; 7:e008721. [PMID: 30371163 PMCID: PMC6201414 DOI: 10.1161/jaha.118.008721] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 07/02/2018] [Indexed: 01/19/2023]
Abstract
Background Phase angle (PA) is a bioimpedance measurement that is determined lean body mass and hydration status. Patients with low PA values are more likely to be frail, sarcopenic, or malnourished. Previous work has shown that low PA predicts adverse outcomes after cardiac surgery, but the effect of PA on survival has not previously been assessed in this setting. Methods and Results The BICS (Bioimpedance in Cardiac Surgery) study recruited 277 patients undergoing major cardiac surgery at 2 university-affiliated hospitals in Montreal, QC, Canada. Bioimpedance measurements as well as frailty and nutritional assessments were performed preoperatively. The primary outcome was all-cause mortality. Secondary outcomes were 30-day mortality, postoperative morbidity, and hospital length of stay. There were 10 deaths at 1 month of follow-up and 16 deaths at 12 months of follow-up. PA was associated with age, sex, body mass index, comorbidities, and frailty, as measured by the Short Physical Performance Battery and Fried scales. After adjusting for Society of Thoracic Surgeons-predicted mortality, lower PA was associated with higher mortality at 1 month (adjusted odds ratio, 3.57 per 1° decrease in PA ; 95% confidence interval, 1.35-9.47) and at 12 months (adjusted odds ratio, 3.03 per 1° decrease in PA ; 95% confidence interval, 1.30-7.09), a higher risk of overall morbidity (adjusted hazard ratio, 2.51 per 1° decrease in PA ; 95% confidence interval, 1.32-4.75), and a longer hospital length of stay (adjusted β, 4.8 days per 1° decrease in PA ; 95% confidence interval, 1.3-8.2 days). Conclusions Low PA is associated with frailty and is predictive of mortality, morbidity, and length of stay after major cardiac surgery. Further work is needed to determine the responsiveness of PA to interventions aimed at reversing frailty.
Collapse
Affiliation(s)
- Louis Mullie
- Centre for Clinical EpidemiologyLady Davis InstituteMcGill UniversityMontrealQuebecCanada
- Division of Internal MedicineMcGill UniversityMontrealQuebecCanada
| | - Alexandrine Obrand
- Centre for Clinical EpidemiologyLady Davis InstituteMcGill UniversityMontrealQuebecCanada
- School of EngineeringMassachusetts Institute of TechnologyCambridgeMA
| | - Melissa Bendayan
- Centre for Clinical EpidemiologyLady Davis InstituteMcGill UniversityMontrealQuebecCanada
- Division of Experimental MedicineFaculty of MedicineMcGill UniversityMontrealQuebecCanada
| | - Amanda Trnkus
- Centre for Clinical EpidemiologyLady Davis InstituteMcGill UniversityMontrealQuebecCanada
| | - Marie‐Claude Ouimet
- Centre for Innovative MedicineMcGill University Health CentreMcGill UniversityMontrealQuebecCanada
| | - Emmanuel Moss
- Division of Cardiac SurgeryJewish General HospitalMcGill UniversityMontrealQuebecCanada
| | | | - Lawrence G. Rudski
- Centre for Clinical EpidemiologyLady Davis InstituteMcGill UniversityMontrealQuebecCanada
- Division of CardiologyJewish General HospitalMcGill UniversityMontrealQuebecCanada
| | - Jonathan Afilalo
- Centre for Clinical EpidemiologyLady Davis InstituteMcGill UniversityMontrealQuebecCanada
- Division of Experimental MedicineFaculty of MedicineMcGill UniversityMontrealQuebecCanada
- Division of CardiologyJewish General HospitalMcGill UniversityMontrealQuebecCanada
| |
Collapse
|
42
|
Tomeleri CM, Ribeiro AS, Cavaglieri CR, Deminice R, Schoenfeld BJ, Schiavoni D, Dos Santos L, de Souza MF, Antunes M, Venturini D, Barbosa DS, Sardinha LB, Cyrino ES. Correlations between resistance training-induced changes on phase angle and biochemical markers in older women. Scand J Med Sci Sports 2018; 28:2173-2182. [PMID: 29858504 DOI: 10.1111/sms.13232] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/28/2018] [Indexed: 01/02/2023]
Abstract
The main purpose of this study was to investigate the effects of 12 weeks of resistance training (RT) on phase angle (PhA), inflammatory and oxidative stress biomarkers, and to evaluate whether these RT-induced adaptations are related to PhA changes. Fifty-one older women (70.6 ± 5.1 years; 26.9 ± 4.2 kg/m2 ) were randomly allocated into a training group (TG) that performed 12-week RT or a nonexercising control group (CG). The PhA (Xitron), body composition (DXA), and blood sample measurements (after a 12 hours fast) were performed before and after the intervention. The TG showed a significant (P < .05) increase in PhA (TG: +7.4±5.9% vs CG: -3.6 ± 8.8%), and interleukin-10 (IL-10; TG: +51.8 ± 71.1% vs CG: -46.6 ± 38.0%), and a decrease in tumor necrosis factor alpha (TNF-α; TG: -15.2 ± 11.1% vs CG: +6.9±17.7%), interleukin-6 (IL-6; TG: -17.9 ± 17.8% vs CG: +6.1 ± 24.8%), and C-reactive protein (CRP; TG: -24.1 ± 19.9% vs CG: +43.8 ± 31.1%). Moreover, TG upregulated catalase (TG: +11.4 ± 15.0% vs CG: -6.7 ± 10.2%). Changes in TNF-α (r = -.71), CRP (r = -.65), lower advanced oxidation protein products (r = -.55), and catalase (r = +.73) after RT were correlated with changes in PhA (P < .05). These results suggest that RT improves PhA, inflammatory and oxidative stress biomarkers, and the changes in inflammatory and oxidative damage markers are correlated with changes in PhA.
Collapse
Affiliation(s)
- C M Tomeleri
- Metabolism, Nutrition, and Exercise Laboratory, Londrina State University, Londrina, Brazil.,Exercise Physiology Laboratory, Faculty of Physical Education, University of Campinas-Unicamp, Campinas, Brazil
| | - A S Ribeiro
- Metabolism, Nutrition, and Exercise Laboratory, Londrina State University, Londrina, Brazil.,Center for Research in Health Sciences, University of Northern Parana, Londrina, Brazil
| | - C R Cavaglieri
- Exercise Physiology Laboratory, Faculty of Physical Education, University of Campinas-Unicamp, Campinas, Brazil
| | - R Deminice
- Department of Physical Education, Faculty of Physical Education and Sport, State University of Londrina, Londrina, PR, Brazil
| | - B J Schoenfeld
- Exercise Science Department, CUNY Lehman College, Bronx, New York
| | - D Schiavoni
- Metabolism, Nutrition, and Exercise Laboratory, Londrina State University, Londrina, Brazil
| | - L Dos Santos
- Metabolism, Nutrition, and Exercise Laboratory, Londrina State University, Londrina, Brazil
| | - M F de Souza
- Metabolism, Nutrition, and Exercise Laboratory, Londrina State University, Londrina, Brazil.,Department of Physical Education, Federal University of Vale do São Francisco, Petrolina, Brazil
| | - M Antunes
- Metabolism, Nutrition, and Exercise Laboratory, Londrina State University, Londrina, Brazil
| | - D Venturini
- Clinical Analyses Laboratory, Londrina State University, Londrina, Brazil
| | - D S Barbosa
- Clinical Analyses Laboratory, Londrina State University, Londrina, Brazil
| | - L B Sardinha
- Exercise and Health Laboratory, Faculdade Motricidade Humana, CIPER, Universidade de Lisboa, Lisbon, Portugal
| | - E S Cyrino
- Metabolism, Nutrition, and Exercise Laboratory, Londrina State University, Londrina, Brazil.,Department of Physical Education, Faculty of Physical Education and Sport, State University of Londrina, Londrina, PR, Brazil
| |
Collapse
|
43
|
Mascherini G, Castizo-Olier J, Irurtia A, Petri C, Galanti G. Differences between the sexes in athletes' body composition and lower limb bioimpedance values. Muscles Ligaments Tendons J 2018; 7:573-581. [PMID: 29721459 DOI: 10.11138/mltj/2017.7.4.573] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Introduction The differences between the sexes in body composition are well established, although sports activity at an elite level seems to reduce them. The aim of this study is a comparison of the sexes in terms of athletes' body composition with a three-compartment model and a localized bioimpedance analysis in elite soccer players. Methods 18 female and 18 male elite soccer players of the same age were matched (female=26.2±2.4, male 26.9±2.5; p=0.87). An assessment of body composition was performed through the integration of anthropometrics parameters, skinfold thickness and bioimpedance data. The evaluations were carried out in the morning on a group of athletes who were in a rested condition, having not exercised in the previous 12 hours and having fasted for breakfast. Results A body composition assessment shows higher values in females for hip circumference/ height (female: 0.55±0.03, male: 0.52±0.02; p<0.01) and fat mass index (female: 3.7±0.7 kg/m2, male: 2.4±0.4 kg/m2; p<0.001), while there is no difference between the genders in the extra cellular mass index (female: 7.1±1.2 kg/m2, male: 7.6±0.4 kg/m2; p=0.11). A localized bioimpedance analysis describes well-defined differences in the thighs, while in the calves these differences are reversed for the reactance values. Conclusion Sports activity seems to slightly reduce differences in the whole body. The different adaption at the same physical effort appears to be mainly related to cellular mass. This study shows for the first time localized bioimpedance values in female athletes. Level of evidence II b.
Collapse
Affiliation(s)
- Gabriele Mascherini
- Sports and Exercise Medicine Unit, Department of Experimental and Clinic Medicine, University of Florence, Italy.,INEFC-Barcelona Sports Sciences Research Group, National Institute of Physical Education of Catalonia, University of Barcelona, Barcelona, Spain
| | - Jorge Castizo-Olier
- Sports and Exercise Medicine Unit, Department of Experimental and Clinic Medicine, University of Florence, Italy.,INEFC-Barcelona Sports Sciences Research Group, National Institute of Physical Education of Catalonia, University of Barcelona, Barcelona, Spain
| | - Alfredo Irurtia
- Sports and Exercise Medicine Unit, Department of Experimental and Clinic Medicine, University of Florence, Italy.,INEFC-Barcelona Sports Sciences Research Group, National Institute of Physical Education of Catalonia, University of Barcelona, Barcelona, Spain
| | - Cristian Petri
- Sports and Exercise Medicine Unit, Department of Experimental and Clinic Medicine, University of Florence, Italy.,INEFC-Barcelona Sports Sciences Research Group, National Institute of Physical Education of Catalonia, University of Barcelona, Barcelona, Spain
| | - Giorgio Galanti
- Sports and Exercise Medicine Unit, Department of Experimental and Clinic Medicine, University of Florence, Italy.,INEFC-Barcelona Sports Sciences Research Group, National Institute of Physical Education of Catalonia, University of Barcelona, Barcelona, Spain
| |
Collapse
|
44
|
Fu B, Freeborn TJ. Biceps tissue bioimpedance changes from isotonic exercise-induced fatigue at different intensities. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aaabed] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
45
|
Freeborn TJ, Crenshaw T, Critcher S. Hook artifact correction of localized electrical bioimpedance for improved agreement between different device measurements. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa971b] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
46
|
Shiffman C. Scaling and the frequency dependence of Nyquist plot maxima of the electrical impedance of the human thigh. Physiol Meas 2017; 38:2203-2221. [PMID: 29044047 DOI: 10.1088/1361-6579/aa9470] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To define and elucidate the properties of reduced-variable Nyquist plots. APPROACH Non-invasive measurements of the electrical impedance of the human thigh. A retrospective analysis of the electrical impedances of 154 normal subjects measured over the past decade shows that 'scaling' of the Nyquist plots for human thigh muscles is a property shared by healthy thigh musculature, irrespective of subject and the length of muscle segment. Here the term scaling signifies the near and sometimes 'perfect' coalescence of the separate X versus R plots into one 'reduced' Nyquist plot by the simple expedient of dividing R and X by X m , the value of X at the reactance maximum. To the extent allowed by noise levels one can say that there is one 'universal' reduced Nyquist plot for the thigh musculature of healthy subjects. MAIN RESULTS There is one feature of the Nyquist curves which is not 'universal', however, namely the frequency f m at which the maximum in X is observed. That is found to vary from 10 to 100 kHz. depending on subject and segment length. Analysis shows, however, that the mean value of 1/f m is an accurately linear function of segment length, though there is a small subject-to-subject random element as well. Also, following the recovery of an otherwise healthy victim of ankle fracture demonstrates the clear superiority of measurements above about 800 kHz, where scaling is not observed, in contrast to measurements below about 400 kHz, where scaling is accurately obeyed. SIGNIFICANCE The ubiquity of 'scaling' casts new light on the interpretation of impedance results as they are used in electrical impedance myography and bioelectric impedance analysis.
Collapse
Affiliation(s)
- Carl Shiffman
- Physics department, Northeastern University, Boston, MA, United States of America
| |
Collapse
|
47
|
Buendia R, Candefjord S, Sanchez B, Granhed H, Sjöqvist BA, Örtenwall P, Caragounis EC. Bioimpedance technology for detection of thoracic injury. Physiol Meas 2017; 38:2000-2014. [DOI: 10.1088/1361-6579/aa8de2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
48
|
Present Uses, Future Applications, and Technical Underpinnings of Electrical Impedance Myography. Curr Neurol Neurosci Rep 2017; 17:86. [DOI: 10.1007/s11910-017-0793-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
49
|
Kwon H, Rutkove SB, Sanchez B. Recording characteristics of electrical impedance myography needle electrodes. Physiol Meas 2017; 38:1748-1765. [PMID: 28721951 DOI: 10.1088/1361-6579/aa80ac] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE Neurologists and physiatrists need improved tools for the evaluation of skeletal muscle condition. Here we evaluate needle electrical impedance myography (EIM), a new minimally invasive approach to determine muscle status that could ultimately become a bedside tool for the assessment of neuromuscular disorders. APPROACH We design and study the recording characteristics of tetrapolar EIM needle electrodes combining theory and finite-element model simulations. We then use these results to build and pilot in vivo an EIM needle electrode in the rat gastrocnemius muscle ([Formula: see text]). The dielectric properties of muscle are reported (mean ± standard deviation). RESULTS The numerical simulations show that the contribution of subcutaneous fat and muscle tissues to needle EIM data is <3% and >97%, respectively, and the sensed volume is [Formula: see text] cm3. Apparent resistivity [Formula: see text] [Formula: see text] cm and relative permittivity [Formula: see text] (dimensionless) measured at 10 kHz are in good agreement with in vivo dielectric properties reported in the literature. SIGNIFICANCE The results presented show the feasibility of measuring muscle impedivity in vivo using a needle electrode from 10 kHz to 1 MHz. The development of needle EIM technology can open up a new field of study in electrodiagnostic medicine, with potential applications to both disease diagnosis and biomarker assessment of therapy.
Collapse
Affiliation(s)
- H Kwon
- Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215-5491, United States of America
| | | | | |
Collapse
|
50
|
Inan OT, Whittingslow DC, Teague CN, Hersek S, Pouyan MB, Millard-Stafford M, Kogler GF, Sawka MN. Wearable knee health system employing novel physiological biomarkers. J Appl Physiol (1985) 2017; 124:537-547. [PMID: 28751371 DOI: 10.1152/japplphysiol.00366.2017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Knee injuries and chronic disorders, such as arthritis, affect millions of Americans, leading to missed workdays and reduced quality of life. Currently, after an initial diagnosis, there are few quantitative technologies available to provide sensitive subclinical feedback to patients regarding improvements or setbacks to their knee health status; instead, most assessments are qualitative, relying on patient-reported symptoms, performance during functional tests, and physical examinations. Recent advances have been made with wearable technologies for assessing the health status of the knee (and potentially other joints) with the goal of facilitating personalized rehabilitation of injuries and care for chronic conditions. This review describes our progress in developing wearable sensing technologies that enable quantitative physiological measurements and interpretation of knee health status. Our sensing system enables longitudinal quantitative measurements of knee sounds, swelling, and activity context during clinical and field situations. Importantly, we leverage machine-learning algorithms to fuse the low-level signal and feature data of the measured time series waveforms into higher level metrics of joint health. This paper summarizes the engineering validation, baseline physiological experiments, and human subject studies-both cross-sectional and longitudinal-that demonstrate the efficacy of using such systems for robust knee joint health assessment. We envision our sensor system complementing and advancing present-day practices to reduce joint reinjury risk, to optimize rehabilitation recovery time for a quicker return to activity, and to reduce health care costs.
Collapse
Affiliation(s)
- Omer T Inan
- School of Electrical and Computer Engineering, Georgia Institute of Technology , Atlanta, Georgia.,Coulter Department of Biomedical Engineering, Georgia Institute of Technology , Atlanta, Georgia
| | - Daniel C Whittingslow
- Coulter Department of Biomedical Engineering, Georgia Institute of Technology , Atlanta, Georgia.,School of Medicine, Emory University , Atlanta, Georgia
| | - Caitlin N Teague
- School of Electrical and Computer Engineering, Georgia Institute of Technology , Atlanta, Georgia
| | - Sinan Hersek
- School of Electrical and Computer Engineering, Georgia Institute of Technology , Atlanta, Georgia
| | - Maziyar Baran Pouyan
- School of Electrical and Computer Engineering, Georgia Institute of Technology , Atlanta, Georgia
| | | | - Geza F Kogler
- School of Biological Sciences, Georgia Institute of Technology , Atlanta, Georgia
| | - Michael N Sawka
- School of Biological Sciences, Georgia Institute of Technology , Atlanta, Georgia
| |
Collapse
|