1
|
Dang C, Shao Y, Ding S, Qi H, Zhai W. Polyfunctional and Multisensory Bio-Ionoelastomers Enabled by Covalent Adaptive Networks With Hierarchically Dynamic Bonding. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2406967. [PMID: 39248650 DOI: 10.1002/adma.202406967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Revised: 08/08/2024] [Indexed: 09/10/2024]
Abstract
Developing versatile ionoelastomers, the alternatives to hydrogels and ionogels, will boost the advancement of high-performance ionotronic devices. However, meeting the requirements of bio-derivation, high toughness, high stretchability, autonomous self-healing ability, high ionic conductivity, reprocessing, and favorable recyclability in a single ionoelastomer remains a challenging endeavor. Herein, a dynamic covalent and supramolecular design, lipoic acid (LA)-based dynamic covalent ionoelastomer (DCIE), is proposed via melt building covalent adaptive networks with hierarchically dynamic bonding (CAN-HDB), wherein lithium bonds aid in the dissociation of ions and the integration of dynamic disulfide metathesis, lithium bonds, and binary hydrogen bonds enhances the mechanical performances, self-healing capability, reprocessing, and recyclability. Therefore, the trade-off among mechanical versatility, ionic conductivity, self-healing capability, reprocessing, and recyclability is successfully handled. The obtained DCIE demonstrates remarkable stretchability (1011.7%), high toughness (3877 kJ m-3), high ionic conductivity (3.94 × 10-4 S m-1), outstanding self-healing capability, reprocessing for 3D printing, and desirable recyclability. Significantly, the selective ion transport endows the DCIE with multisensory feature capable of generating continuous electrical signals for high-quality sensations towards temperature, humidity, and strain. Coupled with the straightforward methodology, abundant availability of LA and HPC, as well as multifunction, the DCIEs present new concept of advanced ionic conductors for developing soft ionotronics.
Collapse
Affiliation(s)
- Chao Dang
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore
| | - Yizhe Shao
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore
- State Key Laboratory for Strength and Vibration of Mechanical Structure, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Shuwei Ding
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore
| | - Haobo Qi
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore
| | - Wei Zhai
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Singapore
| |
Collapse
|
2
|
Chen H, Huang X, Yang Y, Li Y. Sodium Alginate/MXene-Based Flexible Humidity Sensors with High-Humidity Durability and Application Potentials in Breath Monitoring and Non-Contact Human-Machine Interfaces. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1694. [PMID: 39513774 PMCID: PMC11547644 DOI: 10.3390/nano14211694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2024] [Revised: 10/18/2024] [Accepted: 10/21/2024] [Indexed: 11/15/2024]
Abstract
Flexible humidity sensors (FHSs) with fast response times and durability to high-humidity environments are highly desirable for practical applications. Herein, an FHS based on crosslinked sodium alginate (SA) and MXene was fabricated, which exhibited high sensitivity (impedance varied from 107 to 105 Ω between 10% and 90% RH), good selectivity, prompt response times (response/recover time of 4 s/11 s), high sensing linearity (R2 = 0.992) on a semi-logarithmic scale, relatively small hysteresis (~5% RH), good repeatability, and good resistance to highly humid environments (negligible changes in sensing properties after being placed in 98% RH over 24 h). It is proposed that the formation of the crosslinking structure of SA and the introduction of MXene with good conductivity and a high specific surface area contributed to the high performance of the composite FHS. Moreover, the FHS could promptly differentiate the respiration status, recognize speech, and measure fingertip movement, indicating potential in breath monitoring and non-contact human-machine interactions. This work provides guidance for developing advanced flexible sensors with a wide application scope in wearable electronics.
Collapse
Affiliation(s)
| | | | | | - Yang Li
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310058, China; (H.C.); (X.H.); (Y.Y.)
| |
Collapse
|
3
|
Brendgen R, Grethe T, Schwarz-Pfeiffer A. Straightforward Production Methods for Diverse Porous PEDOT:PSS Structures and Their Characterization. SENSORS (BASEL, SWITZERLAND) 2024; 24:4919. [PMID: 39123965 PMCID: PMC11314961 DOI: 10.3390/s24154919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 07/25/2024] [Accepted: 07/26/2024] [Indexed: 08/12/2024]
Abstract
Porous conductive polymer structures, in particular Poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) structures, are gaining in importance due to their versatile fields of application as sensors, hydrogels, or supercapacitors, to name just a few. Moreover, (porous) conducting polymers have become of interest for wearable and smart textile applications due to their biocompatibility, which enables applications with direct skin contact. Therefore, there is a huge need to investigate distinct, straightforward, and textile-compatible production methods for the fabrication of porous PEDOT:PSS structures. Here, we present novel and uncomplicated approaches to producing diverse porous PEDOT:PSS structures and characterize them thoroughly in terms of porosity, electrical resistance, and their overall appearance. Production methods comprise the incorporation of micro cellulose, the usage of a blowing agent, creating a sponge-like structure, and spraying onto a porous base substrate. This results in the fabrication of various porous structures, ranging from thin and slightly porous to thick and highly porous. Depending on the application, these structures can be modified and integrated into electronic components or wearables to serve as porous electrodes, sensors, or other functional devices.
Collapse
Affiliation(s)
- Rike Brendgen
- Research Institute for Textile and Clothing (FTB), Niederrhein University of Applied Sciences, Webschulstr. 31, 41065 Moenchengladbach, Germany
| | - Thomas Grethe
- Faculty of Textile and Clothing Technology, Niederrhein University of Applied Sciences, Webschulstr. 31, 41065 Moenchengladbach, Germany (A.S.-P.)
| | - Anne Schwarz-Pfeiffer
- Faculty of Textile and Clothing Technology, Niederrhein University of Applied Sciences, Webschulstr. 31, 41065 Moenchengladbach, Germany (A.S.-P.)
| |
Collapse
|
4
|
Beniwal A, Khandelwal G, Mukherjee R, Mulvihill DM, Li C. Eco-Friendly Textile-Based Wearable Humidity Sensor with Multinode Wireless Connectivity for Healthcare Applications. ACS APPLIED BIO MATERIALS 2024; 7:4772-4784. [PMID: 38963128 PMCID: PMC11253092 DOI: 10.1021/acsabm.4c00593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 06/24/2024] [Accepted: 06/26/2024] [Indexed: 07/05/2024]
Abstract
Textile-based wearable humidity sensors are of great interest for human healthcare monitoring as they can provide critical human-physiology information. The demand for wearable and sustainable sensing technology has significantly promoted the development of eco-friendly sensing solutions for potential real-world applications. Herein, a biodegradable cotton (textile)-based wearable humidity sensor has been developed using fabsil-treated cotton fabric coated with a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) sensing layer. The structural, chemical composition, hygroscopicity, and morphological properties are examined using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), contact angle measurement, and scanning electron microscopy (SEM) analysis. The developed sensor exhibited a nearly linear response (Adj. R-square value observed as 0.95035) over a broad relative humidity (RH) range from 25 to 91.5%RH displaying high sensitivity (26.1%/%RH). The sensor shows excellent reproducibility (on replica sensors with a margin of error ±1.98%) and appreciable stability/aging with time (>4.5 months), high flexibility (studied at bending angles 30°, 70°, 120°, and 150°), substantial response/recovery durations (suitable for multiple applications), and highly repeatable (multicyclic analysis) sensing performance. The prospective relevance of the developed humidity sensor toward healthcare applications is demonstrated via breathing rate monitoring (via a sensor attached to a face mask), distinguishing different breathing patterns (normal, deep, and fast), skin moisture monitoring, and neonatal care (diaper wetting). The multinode wireless connectivity is demonstrated using a Raspberry Pi Pico-based system for demonstrating the potential applicability of the developed sensor as a real-time humidity monitoring system for the healthcare sector. Further, the biodegradability analysis of the used textile is evaluated using the soil burial degradation test. The work suggests the potential applicability of the developed flexible and eco-friendly humidity sensor in wearable healthcare devices and other humidity sensing applications.
Collapse
Affiliation(s)
- Ajay Beniwal
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, U.K.
| | - Gaurav Khandelwal
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, U.K.
| | - Rudra Mukherjee
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, U.K.
| | - Daniel M. Mulvihill
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, U.K.
| | - Chong Li
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, U.K.
| |
Collapse
|
5
|
Vitazkova D, Foltan E, Kosnacova H, Micjan M, Donoval M, Kuzma A, Kopani M, Vavrinsky E. Advances in Respiratory Monitoring: A Comprehensive Review of Wearable and Remote Technologies. BIOSENSORS 2024; 14:90. [PMID: 38392009 PMCID: PMC10886711 DOI: 10.3390/bios14020090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 01/28/2024] [Accepted: 02/03/2024] [Indexed: 02/24/2024]
Abstract
This article explores the importance of wearable and remote technologies in healthcare. The focus highlights its potential in continuous monitoring, examines the specificity of the issue, and offers a view of proactive healthcare. Our research describes a wide range of device types and scientific methodologies, starting from traditional chest belts to their modern alternatives and cutting-edge bioamplifiers that distinguish breathing from chest impedance variations. We also investigated innovative technologies such as the monitoring of thorax micromovements based on the principles of seismocardiography, ballistocardiography, remote camera recordings, deployment of integrated optical fibers, or extraction of respiration from cardiovascular variables. Our review is extended to include acoustic methods and breath and blood gas analysis, providing a comprehensive overview of different approaches to respiratory monitoring. The topic of monitoring respiration with wearable and remote electronics is currently the center of attention of researchers, which is also reflected by the growing number of publications. In our manuscript, we offer an overview of the most interesting ones.
Collapse
Affiliation(s)
- Diana Vitazkova
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (E.F.); (H.K.); (M.M.); (M.D.); (A.K.)
| | - Erik Foltan
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (E.F.); (H.K.); (M.M.); (M.D.); (A.K.)
| | - Helena Kosnacova
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (E.F.); (H.K.); (M.M.); (M.D.); (A.K.)
- Department of Simulation and Virtual Medical Education, Faculty of Medicine, Comenius University, Sasinkova 4, 81272 Bratislava, Slovakia
| | - Michal Micjan
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (E.F.); (H.K.); (M.M.); (M.D.); (A.K.)
| | - Martin Donoval
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (E.F.); (H.K.); (M.M.); (M.D.); (A.K.)
| | - Anton Kuzma
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (E.F.); (H.K.); (M.M.); (M.D.); (A.K.)
| | - Martin Kopani
- Institute of Medical Physics, Biophysics, Informatics and Telemedicine, Faculty of Medicine, Comenius University, Sasinkova 2, 81272 Bratislava, Slovakia;
| | - Erik Vavrinsky
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia; (E.F.); (H.K.); (M.M.); (M.D.); (A.K.)
- Institute of Medical Physics, Biophysics, Informatics and Telemedicine, Faculty of Medicine, Comenius University, Sasinkova 2, 81272 Bratislava, Slovakia;
| |
Collapse
|
6
|
Oechsle AL, Schöner T, Deville L, Xiao T, Tian T, Vagias A, Bernstorff S, Müller-Buschbaum P. Ionic Liquid-Induced Inversion of the Humidity-Dependent Conductivity of Thin PEDOT:PSS Films. ACS APPLIED MATERIALS & INTERFACES 2023; 15:47682-47691. [PMID: 37756141 DOI: 10.1021/acsami.3c08208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
The humidity influence on the electronic and ionic resistance properties of thin post-treated poly(3,4-ethylene dioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) films is investigated. In particular, the resistance of these PEDOT:PSS films post-treated with three different concentrations (0, 0.05, and 0.35 M) of ethyl-3-methylimidazolium dicyanamide (EMIM DCA) is measured while being exposed to a defined humidity protocol. A resistance increase upon elevated humidity is observed for the 0 M reference sample, while the EMIM DCA post-treated samples demonstrate a reverse behavior. Simultaneously performed in situ grazing-incidence small-angle X-ray scattering (GISAXS) measurements evidence changes in the film morphology upon varying the humidity, namely, an increase in the PEDOT domain distances. This leads to a detriment in the interdomain hole transport, which causes a rise in the resistance, as observed for the 0 M reference sample. Finally, electrochemical impedance spectroscopy (EIS) measurements at different humidities reveal additional contributions of ionic charge carriers in the EMIM DCA post-treated PEDOT:PSS films. Therefrom, a model is proposed, which describes the hole and cation transport in different post-treated PEDOT:PSS films dependent on the ambient humidity.
Collapse
Affiliation(s)
- Anna Lena Oechsle
- TUM School of Natural Science, Department of Physics, Chair for Functional Materials, Technical University of Munich, James Franck-Str. 1, 85748 Garching, Germany
| | - Tobias Schöner
- TUM School of Natural Science, Department of Physics, Chair for Functional Materials, Technical University of Munich, James Franck-Str. 1, 85748 Garching, Germany
| | - Lewin Deville
- TUM School of Natural Science, Department of Physics, Chair for Functional Materials, Technical University of Munich, James Franck-Str. 1, 85748 Garching, Germany
| | - Tianxiao Xiao
- TUM School of Natural Science, Department of Physics, Chair for Functional Materials, Technical University of Munich, James Franck-Str. 1, 85748 Garching, Germany
| | - Ting Tian
- TUM School of Natural Science, Department of Physics, Chair for Functional Materials, Technical University of Munich, James Franck-Str. 1, 85748 Garching, Germany
| | - Apostolos Vagias
- Heinz Maier-Leibnitz Zentrum (MLZ), Technical University of Munich, Lichtenbergstr. 1, 85748 Garching, Germany
| | - Sigrid Bernstorff
- Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale 14 Km 163.5, AREA Science Park, Basovizza 34149, Trieste, Italy
| | - Peter Müller-Buschbaum
- TUM School of Natural Science, Department of Physics, Chair for Functional Materials, Technical University of Munich, James Franck-Str. 1, 85748 Garching, Germany
- Heinz Maier-Leibnitz Zentrum (MLZ), Technical University of Munich, Lichtenbergstr. 1, 85748 Garching, Germany
| |
Collapse
|
7
|
Ku CA, Chung CK. Advances in Humidity Nanosensors and Their Application: Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23042328. [PMID: 36850926 PMCID: PMC9960561 DOI: 10.3390/s23042328] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 02/15/2023] [Accepted: 02/16/2023] [Indexed: 05/27/2023]
Abstract
As the technology revolution and industrialization have flourished in the last few decades, the development of humidity nanosensors has become more important for the detection and control of humidity in the industry production line, food preservation, chemistry, agriculture and environmental monitoring. The new nanostructured materials and fabrication in nanosensors are linked to better sensor performance, especially for superior humidity sensing, following the intensive research into the design and synthesis of nanomaterials in the last few years. Various nanomaterials, such as ceramics, polymers, semiconductor and sulfide, carbon-based, triboelectrical nanogenerator (TENG), and MXene, have been studied for their potential ability to sense humidity with structures of nanowires, nanotubes, nanopores, and monolayers. These nanosensors have been synthesized via a wide range of processes, including solution synthesis, anodization, physical vapor deposition (PVD), or chemical vapor deposition (CVD). The sensing mechanism, process improvement and nanostructure modulation of different types of materials are mostly inexhaustible, but they are all inseparable from the goals of the effective response, high sensitivity and low response-recovery time of humidity sensors. In this review, we focus on the sensing mechanism of direct and indirect sensing, various fabrication methods, nanomaterial geometry and recent advances in humidity nanosensors. Various types of capacitive, resistive and optical humidity nanosensors are introduced, alongside illustration of the properties and nanostructures of various materials. The similarities and differences of the humidity-sensitive mechanisms of different types of materials are summarized. Applications such as IoT, and the environmental and human-body monitoring of nanosensors are the development trends for futures advancements.
Collapse
|
8
|
High Throughput Fabrication of Flexible Top-Driven Sensing Probe. Polymers (Basel) 2022; 14:polym14235124. [PMID: 36501518 PMCID: PMC9738077 DOI: 10.3390/polym14235124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/20/2022] [Accepted: 11/21/2022] [Indexed: 11/27/2022] Open
Abstract
In this work, considering the current status of conservative and complicated traditional thrombosis treatment methods, a kind of flexible intelligent probe (FIP) with a top-driven sensing strategy is proposed to realize the expected function of thrombosis accurate localization in a liquid flow environment. After throughput fabrication, we find that the FIP has excellent electrical conductivity and mechanical properties. Notable, our FIP with the principle of piezo-resistive sensing has a quasi-linear sensitivity (approx. 0.325 L per minute) to flow sensing in the low flow velocity range (0-1 L per minute). Via the well-designed magnetically driven method, our FIP has a maximum deflection output force of 443.264 mN, a maximum deflection angle of 43°, and a maximum axial force of 54.176 mN. We demonstrate that the FIP is capable of completing the specified command actions relatively accurately and has a good response to real-time sensing feedback performance, which has broad application prospects in thrombus localization detection.
Collapse
|
9
|
Yang W, Li W, Lu H, Liu J, Zhang T. Dynamic Compensation Method for Humidity Sensors Based on Temperature and Humidity Decoupling. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197229. [PMID: 36236326 PMCID: PMC9570529 DOI: 10.3390/s22197229] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2022] [Revised: 09/11/2022] [Accepted: 09/14/2022] [Indexed: 05/14/2023]
Abstract
Currently, integrated humidity sensors with fast-response time are widely needed. The most commonly used polyimide capacitive humidity sensor has a long response time, which is difficult to meet the need for a fast response. Most studies focusing on technology and materials have a high cost and are difficult to ensure compatability with the CMOS process. The dynamic compensation method can shorten the response time by only adding digital circuits or software processing. However, conventional compensation technology is not suitable for humidity sensors due to temperature coupling. This paper proposes a new dynamic compensation method for humidity sensors based on the decoupling of temperature factors by analyzing the coupling relationship between sensor dynamic characteristics and temperature. Simulations and experiments were used to verify the proposed method. The experimental results show that the proposed method reduces the humidity response time of the sensor by 85.6%. The proposed method can effectively shorten the response time of humidity sensors.
Collapse
Affiliation(s)
- Wenxuan Yang
- Key Laboratory of Solid-State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wenchang Li
- Key Laboratory of Solid-State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
- University of Chinese Academy of Sciences, Beijing 100049, China
- Correspondence:
| | - Huaxiang Lu
- University of Chinese Academy of Sciences, Beijing 100049, China
- Semiconductor Neural Network Intelligent Perception and Computing Technology Beijing Key Laboratory, Beijing 100083, China
| | - Jian Liu
- University of Chinese Academy of Sciences, Beijing 100049, China
- State Key Laboratory of Superlattices and Microstructures, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | - Tianyi Zhang
- Key Laboratory of Solid-State Optoelectronics Information Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
10
|
Ultrasensitive, stretchable, and transparent humidity sensor based on ion-conductive double-network hydrogel thin films. SCIENCE CHINA MATERIALS 2022; 65:2540-2552. [PMID: 35600911 PMCID: PMC9109751 DOI: 10.1007/s40843-021-2022-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 03/07/2022] [Indexed: 11/15/2022]
Abstract
Ion-conductive hydrogels with intrinsic biocompatibility, stretchability, and stimuli-responsive capability have attracted considerable attention because of their extensive application potential in wearable sensing devices. The miniaturization and integration of hydrogel-based devices are currently expected to achieve breakthroughs in device performance and promote their practical application. However, currently, hydrogel film is rarely reported because it can be easily wrinkled, torn, and dehydrated, which severely hinders its development in microelectronics. Herein, thin, stretchable, and transparent ion-conductive double-network hydrogel films with controllable thickness are integrated with stretchable elastomer substrates, which show good environmental stability and ultrahigh sensitivity to humidity (78,785.5%/% relative humidity (RH)). Benefiting from the ultrahigh surface-area-to-volume ratio, abundant active sites, and short diffusion distance, the hydrogel film humidity sensor exhibits 2 × 105 times increased response to 98% RH, as well as 5.9 and 7.6 times accelerated response and recovery speeds compared with the bulk counterpart, indicating its remarkable thickness-dependent humidity-sensing properties. The humidity-sensing mechanism reveals that the adsorption of water improves the ion migration and dielectric constant, as well as establishes the electrical double layer. Furthermore, the noncontact human-machine interaction and real-time respiratory frequency detection are enabled by the sensors. This work provides an innovative strategy to achieve further breakthroughs in device performance and promote the development of hydrogel-based miniaturized and integrated electronics.
![]()
Collapse
|
11
|
Akram R, Saleem M, Farooq Z, Yaseen M, Almohaimeed ZM, Zafar Q. Integrated Capacitive- and Resistive-Type Bimodal Relative Humidity Sensor Based on 5,10,15,20-Tetraphenylporphyrinatonickel(II) (TPPNi) and Zinc Oxide (ZnO) Nanocomposite. ACS OMEGA 2022; 7:30590-30600. [PMID: 36061702 PMCID: PMC9434763 DOI: 10.1021/acsomega.2c04313] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 08/10/2022] [Indexed: 06/01/2023]
Abstract
The development of high-performance humidity sensors to cater for a plethora of applications, ranging from agriculture to intelligent medical monitoring systems, calls for the selection of a reliable and ultrasensitive sensing material. A simplistic device architecture, robust quantification of ambient relative humidity (% RH), and compatibility with the contemporary integrated circuit technology make a bimodal (capacitive and resistive) surface-type sensor to be a prominent choice for device fabrication. Herein, we have proposed and demonstrated a facile realization of a 5,10,15,20-tetraphenylporphyrinatonickel (II)-zinc oxide (TPPNi-ZnO) nanocomposite-based bimodal surface-type % RH sensor. The TPPNi macromolecule and ZnO nanoparticles have been synthesized by an eco-benign microwave-assisted technique and a thermal-budget chemical precipitation method, respectively. It is speculated from the morpohological study that specific surface area improvement, via the provision of ZnO nanoparticles on micro-pyramidal structures of TPPNi, may reinforce the sensing properties of the fabricated humidity sensor. The relative humidity sensing capacitive and resistive characteristics of the sensor have been monitored in 40-85% relative humidity (% RH) bandwidth. The fabricated sensor under the biasing conditions of 1 V of applied bias (V rms) and 500 Hz AC test frequency exhibits a significantly higher sensitivity of 387.03 pF/% RH and 95.79 kΩ/% RH in bimodal operation. The average values of both the response and recovery times of the capacitive sensor have been estimated to be ∼30 s. It has also been debated why this high degree of sensitivity and considerable reduction in response/recovery time has been obtained. In addition, the intense and wide bandwidth spectral response of the TPPNi-ZnO nanocomposite indicates that it may also be utilized as a potential light-harvesting heterostructured nanohybrid in future studies.
Collapse
Affiliation(s)
- Rizwan Akram
- Department
of Electrical Engineering, College of Engineering, Qassim University, P.O. Box 6677, Buraydah 51452, Saudi
Arabia
| | - Muhammad Saleem
- Department
of Physics, University of Management and
Technology, Lahore 54000, Pakistan
| | - Zahid Farooq
- Department
of Physics, Division of Science & Technology, University of Education, Lahore 54000, Pakistan
| | - Muhammad Yaseen
- Department
of Chemistry, Division of Science & Technology, University of Education, Lahore 54000, Pakistan
| | - Ziyad M. Almohaimeed
- Department
of Electrical Engineering, College of Engineering, Qassim University, P.O. Box 6677, Buraydah 51452, Saudi
Arabia
| | - Qayyum Zafar
- Department
of Physics, University of Management and
Technology, Lahore 54000, Pakistan
| |
Collapse
|
12
|
Cotur Y, Olenik S, Asfour T, Bruyns-Haylett M, Kasimatis M, Tanriverdi U, Gonzalez-Macia L, Lee HS, Kozlov AS, Güder F. Bioinspired Stretchable Transducer for Wearable Continuous Monitoring of Respiratory Patterns in Humans and Animals. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2203310. [PMID: 35730340 DOI: 10.1002/adma.202203310] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 06/15/2022] [Indexed: 06/15/2023]
Abstract
A bio-inspired continuous wearable respiration sensor modeled after the lateral line system of fish is reported which is used for detecting mechanical disturbances in the water. Despite the clinical importance of monitoring respiratory activity in humans and animals, continuous measurements of breathing patterns and rates are rarely performed in or outside of clinics. This is largely because conventional sensors are too inconvenient or expensive for wearable sensing for most individuals and animals. The bio-inspired air-silicone composite transducer (ASiT) is placed on the chest and measures respiratory activity by continuously measuring the force applied to an air channel embedded inside a silicone-based elastomeric material. The force applied on the surface of the transducer during breathing changes the air pressure inside the channel, which is measured using a commercial pressure sensor and mixed-signal wireless electronics. The transducer produced in this work are extensively characterized and tested with humans, dogs, and laboratory rats. The bio-inspired ASiT may enable the early detection of a range of disorders that result in altered patterns of respiration. The technology reported can also be combined with artificial intelligence and cloud computing to algorithmically detect illness in humans and animals remotely, reducing unnecessary visits to clinics.
Collapse
Affiliation(s)
- Yasin Cotur
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | - Selin Olenik
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | - Tarek Asfour
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | | | - Michael Kasimatis
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | - Ugur Tanriverdi
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | | | - Hong Seok Lee
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | - Andrei S Kozlov
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | - Firat Güder
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| |
Collapse
|
13
|
Cho MY, Kim IS, Kim MJ, Hyun DE, Koo SM, Sohn H, Kim NY, Kim S, Ko S, Oh JM. NaCl Ionization-Based Moisture Sensor Prepared by Aerosol Deposition for Monitoring Respiratory Patterns. SENSORS (BASEL, SWITZERLAND) 2022; 22:5178. [PMID: 35890859 PMCID: PMC9317478 DOI: 10.3390/s22145178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Revised: 06/27/2022] [Accepted: 07/05/2022] [Indexed: 06/15/2023]
Abstract
A highly polarizable moisture sensor with multimodal sensing capabilities has great advantages for healthcare applications such as human respiration monitoring. We introduce an ionically polarizable moisture sensor based on NaCl/BaTiO3 composite films fabricated using a facile aerosol deposition (AD) process. The proposed sensing model operates based on an enormous NaCl ionization effect in addition to natural moisture polarization, whereas all previous sensors are based only on the latter. We obtained an optimal sensing performance in a 0.5 µm-thick layer containing NaCl-37.5 wt% by manipulating the sensing layer thickness and weight fraction of NaCl. The NaCl/BaTiO3 sensing layer exhibits outstanding sensitivity over a wide humidity range and a fast response/recovery time of 2/2 s; these results were obtained by performing the one-step AD process at room temperature without using any auxiliary methods. Further, we present a human respiration monitoring system using a sensing device that provides favorable and stable electrical signals under diverse respiratory scenarios.
Collapse
Affiliation(s)
- Myung-Yeon Cho
- Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (M.-Y.C.); (M.-J.K.); (D.-E.H.); (S.-M.K.)
| | - Ik-Soo Kim
- Department of Materials Science and Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Pohang 37673, Korea;
| | - Min-Ji Kim
- Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (M.-Y.C.); (M.-J.K.); (D.-E.H.); (S.-M.K.)
| | - Da-Eun Hyun
- Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (M.-Y.C.); (M.-J.K.); (D.-E.H.); (S.-M.K.)
| | - Sang-Mo Koo
- Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (M.-Y.C.); (M.-J.K.); (D.-E.H.); (S.-M.K.)
| | - Hiesang Sohn
- Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea;
| | - Nam-Young Kim
- RFIC Center, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea;
| | - Sunghoon Kim
- Department of Applied Chemistry, Dong-Eui University, Busan 47227, Korea;
| | - Seunghoon Ko
- Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (M.-Y.C.); (M.-J.K.); (D.-E.H.); (S.-M.K.)
| | - Jong-Min Oh
- Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea; (M.-Y.C.); (M.-J.K.); (D.-E.H.); (S.-M.K.)
| |
Collapse
|
14
|
High-Performance Room-Temperature Conductometric Gas Sensors: Materials and Strategies. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10060227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Chemiresistive sensors have gained increasing interest in recent years due to the necessity of low-cost, effective, high-performance gas sensors to detect volatile organic compounds (VOC) and other harmful pollutants. While most of the gas sensing technologies rely on the use of high operation temperatures, which increase usage cost and decrease efficiency due to high power consumption, a particular subset of gas sensors can operate at room temperature (RT). Current approaches are aimed at the development of high-sensitivity and multiple-selectivity room-temperature sensors, where substantial research efforts have been conducted. However, fewer studies presents the specific mechanism of action on why those particular materials can work at room temperature and how to both enhance and optimize their RT performance. Herein, we present strategies to achieve RT gas sensing for various materials, such as metals and metal oxides (MOs), as well as some of the most promising candidates, such as polymers and hybrid composites. Finally, the future promising outlook on this technology is discussed.
Collapse
|
15
|
Cho J, Shin G. Fabrication of a Flexible, Wireless Micro-Heater on Elastomer for Wearable Gas Sensor Applications. Polymers (Basel) 2022; 14:polym14081557. [PMID: 35458311 PMCID: PMC9024803 DOI: 10.3390/polym14081557] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 04/07/2022] [Accepted: 04/08/2022] [Indexed: 12/10/2022] Open
Abstract
Thin-film microdevices can be applied to various wearable devices due to their high flexibility compared to conventional bulk-type electronic devices. Among the various microdevice types, many IoT-based sensor devices have been developed recently. In the case of such sensor elements, it is important to control the surrounding environment to optimize the sensing characteristics. Among these environmental factors, temperature often has a great influence. There are cases where temperature significantly affects the sensor characteristics, as is the case for gas sensors. For this purpose, the development of thin-film-type micro-heaters is important. For this study, a wirelessly driven thin-film micro-heater was fabricated on the flexible and stretchable elastomer, a polydimethylsiloxane (PDMS); the antenna was optimized; and the heater was driven at the temperature up to 102 degrees Celsius. The effect of its use on gas-sensing characteristics was compared through the application of the proposed micro-heater to a gas sensor. The heated SnO2 nanowire gas sensor improved the performance of detecting carbon monoxide (CO) by more than 20%, and the recovery time was reduced to less than half. It is expected that thin-film-type micro-heaters that can be operated wirelessly are suitable for application in various wearable devices, including those for smart sensors and health monitoring.
Collapse
|
16
|
Li Y, Jia J, Yu H, Wang S, Jin ZY, Zhang YH, Ma HZ, Zhang K, Ke K, Yin B, Yang MB. Macromolecule Relaxation Directed 3D Nanofiber Architecture in Stretchable Fibrous Mats for Wearable Multifunctional Sensors. ACS APPLIED MATERIALS & INTERFACES 2022; 14:15678-15686. [PMID: 35321545 DOI: 10.1021/acsami.2c02090] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Elastomer fiber mat sensors, which are capable of perceiving mechanical stimuli, temperature, and vapor of chemicals, are highly desirable for designing wearable electronics and human-robot interfacing devices due to good wearability, skin affinity, and durability, and so on. However, it is still challenging to fabricate multiresponsive flexible wearable sensors with three-dimensional (3D) architecture using simple material and structure design. Herein, we report an all-in-one multiresponsive thermoplastic polyurethane (TPU) nanofiber mat sensors composed of crimped elastomer fibers with deposited platinum nanoparticles (PtNPs) on the fiber surface. The 1D TPU nanofibers could be transferred to nanofibers with different 3D nanofiber architectures by controllable macromolecular chain relaxation of aligned elastomer polymers upon poor solvent annealing. The conductive networks of PtNPs on wavy TPU fibers enable the sensor susceptible to multiple stimuli like strain/pressure, humidity, and organic vapors. Besides, the 3D nanofiber architectures allow the strain sensor to detect wider tensile strain and pressure with higher sensitivity due to delicate fiber morphology and structure control. Therefore, this work provides new insights into the fabrication of multifunctional flexible sensors with 3D architecture in an easy way, advancing the establishment of a multiple signal monitoring platform for the health care and human-machine interfacing.
Collapse
Affiliation(s)
- Yan Li
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Jin Jia
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Hua Yu
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Shan Wang
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Zhao-Yuan Jin
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Yu-Hao Zhang
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Hong-Zhi Ma
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Kai Zhang
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Kai Ke
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Bo Yin
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| | - Ming-Bo Yang
- College of Polymer Science and Engineering, Sichuan University, State Key Laboratory of Polymer Materials Engineering, Chengdu, 610065 Sichuan, PR China
| |
Collapse
|
17
|
Falco A, Marín-Sánchez A, Loghin FC, Castillo E, Salinas-Castillo A, Salmerón JF, Rivadeneyra A. Paper and Salt: Biodegradable NaCl-Based Humidity Sensors for Sustainable Electronics. FRONTIERS IN ELECTRONICS 2022. [DOI: 10.3389/felec.2022.838472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Flexible and thin-film humidity sensors are currently attracting the attention of the scientific community due to their portability and reduced size, which are highly useful traits for use in the Internet o Things (IoT) industry. Furthermore, in order to perform efficient and profitable mass production, it is necessary to develop a cost-effective and reproducible fabrication process and materials. Green fabrication methods and biodegradable materials would also minimize the environmental impact and create a sustainable IoT development. In this paper, flexible humidity sensors based on a common salt (NaCl) sensing layer are reported. Our sensors and the fabrication techniques employed, such as dip and spray coating, provide a biodegradable, low cost, and highly reproducible device. One of the sensors reported presents a typical resistive behaviour from 40% RH up to 85% RH with a sensitivity of −0.21 (Z/%RH). The performance of the sensors obtained with several fabrication techniques is studied and reported at multiple frequencies from 100 Hz to 10 MHz, showcasing its versatility and robustness.
Collapse
|
18
|
Zhang X, Yang W, Zhang H, Xie M, Duan X. PEDOT:PSS: From conductive polymers to sensors. NANOTECHNOLOGY AND PRECISION ENGINEERING 2021. [DOI: 10.1063/10.0006866] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Xiaoshuang Zhang
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Wentuo Yang
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Hainan Zhang
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Mengying Xie
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
| |
Collapse
|
19
|
Allison L, Rostaminia S, Kiaghadi A, Ganesan D, Andrew TL. Enabling Longitudinal Respiration Monitoring Using Vapor-Coated Conducting Textiles. ACS OMEGA 2021; 6:31869-31875. [PMID: 34870009 PMCID: PMC8638004 DOI: 10.1021/acsomega.1c04616] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 11/01/2021] [Indexed: 05/24/2023]
Abstract
Wearable sensors allow for portable, long-term health monitoring in natural environments. Recently, there has been an increase in demand for technology that can reliably monitor respiration, which can be indicative of cardiac diseases, asthma, and infection by respiratory viruses. However, to date, the most reliable respiration monitoring system involves a tightly worn chest belt that is not conducive to longitudinal monitoring. Herein, we report that accurate respiration monitoring can be effected using a fabric-based humidity sensor mounted within a face mask. Our humidity sensor is created using cotton fabrics coated with a persistently p-doped conjugated polymer, poly(3,4-ethylenedioxythiophene):chloride (PEDOT-Cl), using a previously reported chemical vapor deposition process. The vapor-deposited polymer coating displays a stable, rapid, and reversible change in conductivity with an increase in local humidity, such as the humidity changes experienced within a face mask as the wearer breathes. Thus, when integrated into a face mask, the PEDOT-Cl-coated cotton humidity sensor is able to transduce breaths into an electrical signal. The humidity sensor-incorporated face mask is able to differentiate between deep and shallow breathing, as well as breathing versus talking. The sensor-incorporated face mask platform also functions both while walking and sitting, providing equally high signal quality in both indoor and outdoor contexts. Additionally, we show that the face mask can be worn for long periods of time with a negligible decline in the signal quality.
Collapse
Affiliation(s)
- Linden
K. Allison
- Department
of Chemistry, University of Massachusetts
Amherst, Amherst, Massachusetts 01002, United States
| | - Soha Rostaminia
- College
of Computer Science, University of Massachusetts
Amherst, Amherst, Massachusetts 01002, United States
| | - Ali Kiaghadi
- College
of Computer Science, University of Massachusetts
Amherst, Amherst, Massachusetts 01002, United States
- Department
of Electrical Engineering, University of
Massachusetts Amherst, Amherst, Massachusetts 01002, United States
| | - Deepak Ganesan
- College
of Computer Science, University of Massachusetts
Amherst, Amherst, Massachusetts 01002, United States
| | - Trisha L. Andrew
- Department
of Chemistry, University of Massachusetts
Amherst, Amherst, Massachusetts 01002, United States
- Department
of Chemical Engineering, University of Massachusetts
Amherst, Amherst, Massachusetts 01002, United States
| |
Collapse
|
20
|
Yang W, Xie M, Zhang X, Sun X, Zhou C, Chang Y, Zhang H, Duan X. Multifunctional Soft Robotic Finger Based on a Nanoscale Flexible Temperature-Pressure Tactile Sensor for Material Recognition. ACS APPLIED MATERIALS & INTERFACES 2021; 13:55756-55765. [PMID: 34780161 DOI: 10.1021/acsami.1c17923] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Robotic hands with tactile perception can perform more advanced and safer operations, such as material recognition. Nanowires with high sensitivity, fast response, and low power consumption are suitable for multifunctional flexible tactile sensors to provide the tactile perception of robotic hands. In this work, we designed a multifunctional soft robotic finger with a built-in nanoscale temperature-pressure tactile sensor for material recognition. The flexible multifunctional tactile sensor integrates a nanowire-based temperature sensor and a conductive sponge pressure sensor to measure the temperature change rate and contact pressure simultaneously. The developed nanoscale temperature and conductive sponge pressure sensor can reach a high sensitivity of 1.196%/°C and 13.29%/kPa, respectively. With this multifunctional tactile sensor, the soft finger can quickly recognize four metals within three contact pressure ranges and 13 materials within a high contact pressure range. By combining tactile information and artificial neural networks, the soft finger can recognize the materials precisely with a high recognition accuracy of 92.7 and 95.9%, respectively. This work proves the application potential of the multifunctional soft robot finger in material recognition.
Collapse
Affiliation(s)
- Wentuo Yang
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Mengying Xie
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xiaoshuang Zhang
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xueyou Sun
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Cheng Zhou
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Ye Chang
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Hainan Zhang
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
| |
Collapse
|
21
|
Chen X, Jiang S, Li Z, Lo B. A Pervasive Respiratory Monitoring Sensor for COVID-19 Pandemic. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2021; 2:11-16. [PMID: 34786558 PMCID: PMC8545027 DOI: 10.1109/ojemb.2020.3042051] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 11/14/2020] [Accepted: 11/30/2020] [Indexed: 12/19/2022] Open
Abstract
Goal: The SARS-CoV-2 viral infection could cause severe acute respiratory syndrome, disturbing the regular breathing and leading to continuous coughing. Automatic respiration monitoring systems could provide the necessary metrics and warnings for timely intervention, especially for those with mild symptoms. Current respiration detection systems are expensive and too obtrusive for any large-scale deployment. Thus, a low-cost pervasive ambient sensor is proposed. Methods: We will posit a barometer on the working desk and develop a novel signal processing algorithm with a sparsity-based filter to remove the similar-frequency noise. Three modes (coughing, breathing and others) will be conducted to detect coughing and estimate different respiration rates. Results: The proposed system achieved 97.33% accuracy of cough detection and 98.98% specificity of respiration rate estimation. Conclusions: This system could be used as an effective screening tool for detecting subjects suffering from COVID-19 symptoms and enable large scale monitoring of patients diagnosed with or recovering.
Collapse
Affiliation(s)
| | - Shuo Jiang
- College of Electronics and Information EngineeringTongji University Shanghai 201804 China
| | - Zeyu Li
- Department of Electrical and Computer EngineeringDuke University Durham NC 27708 USA
| | - Benny Lo
- Hamlyn CentreImperial College London London SW7 2AZ U.K
| |
Collapse
|
22
|
Liu R, He L, Cao M, Sun Z, Zhu R, Li Y. Flexible Temperature Sensors. Front Chem 2021; 9:539678. [PMID: 34631655 PMCID: PMC8492987 DOI: 10.3389/fchem.2021.539678] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 09/07/2021] [Indexed: 01/19/2023] Open
Abstract
Temperature reflects the balance between production and dissipate of heat. Flexible temperature sensors are primary sensors used for temperature monitoring. To obtain real-time and accurate information of temperature, different flexible temperature sensors are developed according to the principle of flexible resistance temperature detector (FRTC), flexible thermocouple, flexible thermistor and flexible thermochromic, showing great potential in energy conversion and storage. In order to obtain high integration and multifunction, various flexible temperature sensors are studied and optimized, including active-matrix flexible temperature sensor, self-powered flexible temperature sensor, self-healing flexible temperature sensor and self-cleaning flexible temperature sensor. This review focuses on the structure, material, fabrication and performance of flexible temperature sensors. Also, some typical applications of flexible temperature sensors are discussed and summarized.
Collapse
Affiliation(s)
- Ruping Liu
- Beijing Institute of Graphic Communication, Beijing, China
| | - Liang He
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan, China
| | - Meijuan Cao
- Beijing Institute of Graphic Communication, Beijing, China
| | - Zhicheng Sun
- Beijing Institute of Graphic Communication, Beijing, China
| | - Ruiqi Zhu
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan, China
| | - Ye Li
- Beijing Institute of Graphic Communication, Beijing, China
| |
Collapse
|
23
|
Xue Q, Kan X, Pan Z, Li Z, Pan W, Zhou F, Duan X. An intelligent face mask integrated with high density conductive nanowire array for directly exhaled coronavirus aerosols screening. Biosens Bioelectron 2021; 186:113286. [PMID: 33990035 PMCID: PMC8091738 DOI: 10.1016/j.bios.2021.113286] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 04/19/2021] [Accepted: 04/23/2021] [Indexed: 01/10/2023]
Abstract
The current ongoing outbreak of Coronavirus Disease 2019 (COVID-19) has globally affected the lives of more than one hundred million people. RT-PCR based molecular test is recommended as the gold standard method for diagnosing current infections. However, transportation and processing of the clinical sample for detecting virus require an expert operator and long processing time. Testing device enables on-site virus detection could reduce the sample-to-answer time, which plays a central role in containing the pandemic. In this work, we proposed an intelligent face mask, where a flexible immunosensor based on high density conductive nanowire array, a miniaturized impedance circuit, and wireless communication units were embedded. The sub-100 nm size and the gap between the neighbored nanowires facilitate the locking of nanoscale virus particles by the nanowire arrays and greatly improve the detection efficiency. Such a point-of-care (POC) system was demonstrated for coronavirus 'spike' protein and whole virus aerosol detection in simulated human breath. Detection of viral concentration as low as 7 pfu/mL from the atomized sample of coronavirus aerosol mimic was achieved in only 5 min. The POC systems can be readily applied for preliminary screening of coronavirus infections on-site and may help to understand the COVID-19 progression while a patient is under prescribed therapy.
Collapse
Affiliation(s)
- Qiannan Xue
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Xinyuan Kan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Zhihao Pan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Zheyu Li
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Wenwei Pan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Feng Zhou
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelec-tronics Engineering, Tianjin University, Tianjin, 300072, China.
| |
Collapse
|
24
|
Application of PEDOT:PSS and Its Composites in Electrochemical and Electronic Chemosensors. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9040079] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) is a highly important and attractive conducting polymer as well as commercially available in organic electronics, including electrochemical and electronic chemosensors, due to its unique features such as excellent solution-fabrication capability and miscibility, high and controllable conductivity, excellent chemical and electrochemical stability, good optical transparency and biocompatibility. In this review, we present a comprehensive overview of the recent research progress of PEDOT:PSS and its composites, and the application in electrochemical and electronic sensors for detecting liquid-phase or gaseous chemical analytes, including inorganic or organic ions, pH, humidity, hydrogen peroxide (H2O2), ammonia (NH3), CO, CO2, NO2, and organic solvent vapors like methanol, acetone, etc. We will discuss in detail the structural, architectural and morphological optimization of PEDOT:PSS and its composites with other additives, as well as the fabrication technology of diverse sensor systems in response to a wide range of analytes in varying environments. At the end of the review will be given a perspective summary covering both the key challenges and potential solutions in the future research of PEDOT:PSS-based chemosensors, especially those in a flexible or wearable format.
Collapse
|
25
|
Delipinar T, Shafique A, Gohar MS, Yapici MK. Fabrication and Materials Integration of Flexible Humidity Sensors for Emerging Applications. ACS OMEGA 2021; 6:8744-8753. [PMID: 33842746 PMCID: PMC8028014 DOI: 10.1021/acsomega.0c06106] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 03/16/2021] [Indexed: 05/05/2023]
Abstract
In the past decade, humidity measurements have ubiquitously gained consideration in the wide range of application paradigms such as industrial predictive maintenance, instrumentation, automation, agriculture, climate monitoring, healthcare, and semiconductor industries. Accurate humidity measurements and cost-effective fabrication processes for large-volume and high-performance sensors with flexible form factors are essential to meet the stringent performance requirements of the emerging application areas. To address this need, recent efforts focus on development of innovative sensing modalities, process technologies, and exploration and integration of new materials to enable low-cost, robust, and flexible humidity sensors with ultrahigh sensitivity and linearity, large dynamic range, low hysteresis, and fast response time. In this review paper, we present an overview of flexible humidity sensors based on distinct sensing mechanisms, employed processing techniques, and various functional sensing layers and substrate materials for specific applications. Furthermore, we present the critical device design parameters considered to be indicative of sensor performance such as relative humidity range, along with a discussion on some of the specific applications and use cases.
Collapse
Affiliation(s)
- Tugce Delipinar
- Faculty
of Engineering and Natural Sciences, Sabanci
University, Istanbul 34956, Turkey
| | - Atia Shafique
- Flexible
Electronics R&D Platform, Kordsa, Izmit 41310, Turkey
| | - Maryam Sepehri Gohar
- Faculty
of Engineering and Natural Sciences, Sabanci
University, Istanbul 34956, Turkey
| | - Murat Kaya Yapici
- Faculty
of Engineering and Natural Sciences, Sabanci
University, Istanbul 34956, Turkey
- Department
of Electrical Engineering, University of
Washington, Seattle, Washington 98195, United States
- SUNUM
Nanotechnology Research Center, Sabanci
University, Istanbul 34956, Turkey
| |
Collapse
|
26
|
Cho MY, Kim IS, Kim SH, Park C, Kim NY, Kim SW, Kim S, Oh JM. Unique Noncontact Monitoring of Human Respiration and Sweat Evaporation Using a CsPb 2Br 5-Based Sensor. ACS APPLIED MATERIALS & INTERFACES 2021; 13:5602-5613. [PMID: 33496182 DOI: 10.1021/acsami.0c21097] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Respiration monitoring and human sweat sensing have promising application prospects in personal healthcare data collection, disease diagnostics, and the effective prevention of human-to-human transmission of fatal viruses. Here, we have introduced a unique respiration monitoring and touchless sensing system based on a CsPb2Br5/BaTiO3 humidity-sensing layer operated by water-induced interfacial polarization and prepared using a facile aerosol deposition process. Based on the relationship between sensing ability and layer thickness, the sensing device with a 1.0 μm thick layer was found to exhibit optimal sensing performance, a result of its ideal microstructure. This sensor also exhibits the highest electrical signal variation at 0.5 kHz due to a substantial polarizability difference between high and low humidity. As a result, the CsPb2Br5/BaTiO3 sensing device shows the best signal variation of all types of breath-monitoring devices reported to date when used to monitor sudden changes in respiratory rates in diverse situations. Furthermore, the sensor can effectively detect sweat evaporation when placed 1 cm from the skin, including subtle changes in capacitance caused by finger area and motion, skin moisture, and contact time. This ultrasensitive sensor, with its fast response, provides a potential new sensing platform for the long-term daily monitoring of respiration and sweat evaporation.
Collapse
Affiliation(s)
- Myung-Yeon Cho
- Department of Electronic Materials Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| | - Ik-Soo Kim
- Department of Electronic Materials Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| | - Seok-Hun Kim
- Department of Applied Chemistry, Dong-eui University, Busan 47227, Republic of Korea
| | - Chulhwan Park
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| | - Nam-Young Kim
- RFIC Center, Department of Electronic Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| | - Sang-Wook Kim
- Nanomaterials Laboratory, Department of Molecular Science and Technology, Ajou University, Suwon 16499, Republic of Korea
| | - Sunghoon Kim
- Department of Applied Chemistry, Dong-eui University, Busan 47227, Republic of Korea
| | - Jong-Min Oh
- Department of Electronic Materials Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| |
Collapse
|
27
|
Tang G, Qiao Y, Yu L, Li CM, Lu Z. Re-stickable All-Solid-State Supercapacitor Supported by Cohesive Thermoplastic for Textile Electronics. ACS APPLIED MATERIALS & INTERFACES 2020; 12:45322-45331. [PMID: 32914958 DOI: 10.1021/acsami.0c13687] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The textile-based flexible electronic device has attracted considerable attention due to its excellent conformability, skin affinity, and compatibility with the clothing industry. However, the machine-washing process may damage the electronic components, further resulting in the failure of the device. Herein, parafilm, a commercially available cohesive thermoplastic, is introduced as both a substrate and encapsulating material to fabricate an all-solid-state supercapacitor, which could be tightly stuck on and easily peeled off from a fabric. The supercapacitor possesses excellent capacitive behavior (73.7 F/g at a current density of 1 A/g), long cycle life (capacitance retention >90% after 5000 cycles), and great flexibility (capacitance retention >98% after 100 times of bending/twisting). After water flushing and soaking, the capacitance of the supercapacitor could be retained at about 98% of its original level. A parafilm-based piezoresistive sensor with good pressure-sensing performance has also been fabricated via the same approach to demonstrate the universality of the proposed strategy for textile re-stickable electronics. This work may not only fabricate novel flexible electronic systems for wearable applications but also provide a universal strategy to address the machine-washing issues in textile electronics.
Collapse
Affiliation(s)
- Guilin Tang
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
- Institute for Clean Energy & Advanced Materials, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
| | - Yan Qiao
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
- Institute for Clean Energy & Advanced Materials, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
| | - Ling Yu
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
- Institute for Clean Energy & Advanced Materials, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
| | - Chang Ming Li
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
- Institute for Clean Energy & Advanced Materials, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
- Institute of Advanced Cross-field Science, Qingdao University, Qingdao 266071, P. R. China
| | - Zhisong Lu
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
- Institute for Clean Energy & Advanced Materials, School of Materials & Energy, Southwest University, 1 Tiansheng Road, Chongqing 400715, P. R. China
| |
Collapse
|
28
|
Xue Q, Li Z, Wang Q, Pan W, Chang Y, Duan X. Nanostrip flexible microwave enzymatic biosensor for noninvasive epidermal glucose sensing. NANOSCALE HORIZONS 2020; 5:934-943. [PMID: 32301449 DOI: 10.1039/d0nh00098a] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Microwave sensors based on microstrip antennas are promising as wearable devices because of their flexibility and wireless communication compatibility. However, their sensitivity is limited due to the reduced sensor size and the potential of biochemical monitoring needs to be explored. In this work, we present a new concept to enhance the microwave signals using nanostrip-based metamaterials. The introduction of the nanostrip structures was achieved by theory and simulations. Experiments prove their enhancement of the electric field and sensing response in the characteristic gigahertz (GHz) wave band. Ordered nanostrips were fabricated on a plastic substrate through a simple nanoscale printing approach. Glucose oxidase is directly doped into the nanostrips, which enables a flexible wearable enzymatic biosensor for glucose sensing. Sensing experiments demonstrated that the nanostrip biosensor gives excellent performance for glucose detection, including high sensitivity, fast response, low detection limit, high affinity, and low power consumption. The applicability of the nanostrip-based sensor as a wearable epidermal device for real-time noninvasive monitoring of glucose in sweat is verified as well.
Collapse
Affiliation(s)
- Qiannan Xue
- State Key Laboratory of Precision Measuring Technology and Instruments, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China.
| | | | | | | | | | | |
Collapse
|
29
|
Luo H, Lin X, Peng Z, Zhou Y, Xu S, Song M, Jin L, Zheng X. A Fast and Highly Selective Nitrite Sensor Based on Interdigital Electrodes Modified With Nanogold Film and Chrome-Black T. Front Chem 2020; 8:366. [PMID: 32411677 PMCID: PMC7201102 DOI: 10.3389/fchem.2020.00366] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2020] [Accepted: 04/08/2020] [Indexed: 11/17/2022] Open
Abstract
Nitrite is a toxic substance, when excessive nitrite enters the human body, it will be seriously harmful to human. At present, the detection methods of nitrite are complicated to operate and require expensive detection instruments. Therefore, an effective, fast and highly selective nanogold film interdigital electrode sensors that can detect nitrite easily and quickly is developed in the work. Firstly, the variation of the sensitivity of nanogold film nitrite sensors with concentrations (1 mol/L, 10−1 mol/L, 10−2 mol/L, 10−3 mol/L, 10−4 mol/L, and 10−5 mol/L) was measured by experiments. Then, Chrome-black T was modified to the surface of the nanogold film interdigital electrodes by electrochemical polymerization, and the film of chrome-black T had affinity for nitrite ions, so nitrite ions were enriched on the sensor surface. The change law of the impedance signal of the modified nanogold film nitrite sensors after being added to different concentrations of sodium nitrite solution were also concluded. The study demonstrates that the larger the concentration of sodium nitrite solution is added to the modified interdigital electrodes, the smaller impedance and resistance of the modified interdigital electrodes are reflected. Finally, specificity of the modified interdigital electrode sensors has been demonstrated. The novel interdigital electrode sensors can detect the concentration of nitrite solution conveniently and quickly with only 30 s. Therefore, the prospect of applying the novel nanogold film interdigital electrode sensors to the detection of nitrite in blood, body fluid, food and drinking water is promising.
Collapse
Affiliation(s)
- Haoyue Luo
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Xiaogang Lin
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Zhijia Peng
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Yong Zhou
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Shibin Xu
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Ming Song
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Lifeng Jin
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Xiaodong Zheng
- Chongqing University Cancer Hospital, Chongqing University, Chongqing, China
| |
Collapse
|
30
|
Soft, Wirelessly Powered Humidity Sensor Based on SnO 2 Nanowires for Wireless/Wearable Sensor Application. MATERIALS 2020; 13:ma13092176. [PMID: 32397314 PMCID: PMC7254362 DOI: 10.3390/ma13092176] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 05/07/2020] [Accepted: 05/07/2020] [Indexed: 11/16/2022]
Abstract
Humidity, along with temperature, is one of the most important environmental variables in people’s lives. The control of humidity is an important matter that is related to material properties and stability in various industries, as well as basic living. In order to detect humidity, changes in the physical, chemical, and electrical properties of materials related to humidity are used, and studies using various methods are conducted. In this study, a field-effect transistor (FET) device was fabricated on a soft polymer substrate with SnO2 nanowires (NWs), whose electrical properties change in response to water molecules. The SnO2 NWs, synthesized by chemical vapor deposition (CVD), were transferred onto a polymer substrate, using a sliding transfer method. The NW FET device, which was connected to an aluminum (Al)-based radio frequency (RF) receiving antenna, was wirelessly operated as a humidity sensor, based on the change in electrical properties of SnO2 NWs according to the relative humidity (RH). It was configured with a wireless antenna and light emitting diode (LED) indicator to implement a soft wirelessly powered humidity sensor that senses high RH and is expected to be used as a wearable electronic/sensor in the future.
Collapse
|
31
|
Song C, Luo H, Lin X, Peng Z, Weng L, Tang X, Xu S, Song M, Jin L, Zheng X. Study on AgInZnS-Graphene Oxide Non-toxic Quantum Dots for Biomedical Sensing. Front Chem 2020; 8:331. [PMID: 32432079 PMCID: PMC7215081 DOI: 10.3389/fchem.2020.00331] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2020] [Accepted: 03/31/2020] [Indexed: 11/20/2022] Open
Abstract
In recent years, non-toxic quantum dot has caught the attention of biomedical fields. However, the inherent cytotoxicity of QDs makes its biomedical application painful, and is a major drawback of this method. In this paper, a non-toxic and water-soluble quantum dot AgInZnS-GO using graphene oxide was synthesized. A simple model of state complex was also established, which is produced through a combination of quantum dots and protein. The interaction between AIZS-GO QDs and human serum albumin (HSA) has significant meaning in vivo biological application. Herein, the binding of AIZS-GO QDs and HSA were researched using fluorescence spectra, Uv-visible absorption spectra, FT-IR spectra, and circular dichroism (CD) spectra. The results of fluorescence spectra demonstrate that AIZS-GO QDs have an obvious fluorescence quenching effect on HSA. The quenching mechanism is static quenching, which implies that some type of complex was produced by the binding of QDs and HSA. These results were further proved by Uv-visible absorption spectroscopy. The Stern-Volmer quenching constant Ksv at various temperatures (298 K, 303 K, 308 K) were acquired from analyzing Stern-Volmer plots of the fluorescence quenching information. The Van't Hoff equation could describe the thermodynamic parameters, which demonstrated that the van der Waals and hydrogen bonds had an essential effect on the interaction. FT-IR spectra and CD spectra further indicate that AIZS-GO QDs can alter the structure of HSA. These spectral methods show that the quantum dot can combine well with HSA. The experimental results showed that AgInZn-GO water-soluble quantum dots have good biocompatibility, which can be combined with proteins to form new compounds which have no cytotoxicity and biological practicability. It provides an important basis for the combination of quantum dots and specific proteins as well as fluorescent labeling.
Collapse
Affiliation(s)
- Chi Song
- Department of Life Science and Technology, Changshu Institute of Technology, Changshu, China
| | - Haoyue Luo
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Xiaogang Lin
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Zhijia Peng
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Lingdong Weng
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Xiaosheng Tang
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Shibin Xu
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Ming Song
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Lifeng Jin
- Key Laboratory of Optoelectronic Technology and Systems of Ministry of Education of China, Chongqing University, Chongqing, China
| | - Xiaodong Zheng
- Chongqing University Cancer Hospital, Chongqing University, Chongqing, China
| |
Collapse
|
32
|
Wang Z, Hu T, Liang R, Wei M. Application of Zero-Dimensional Nanomaterials in Biosensing. Front Chem 2020; 8:320. [PMID: 32373593 PMCID: PMC7182656 DOI: 10.3389/fchem.2020.00320] [Citation(s) in RCA: 75] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Accepted: 03/30/2020] [Indexed: 12/15/2022] Open
Abstract
Zero-dimensional (0D) nanomaterials, including graphene quantum dots (GQDs), carbon quantum dots (CQDs), fullerenes, inorganic quantum dots (QDs), magnetic nanoparticles (MNPs), noble metal nanoparticles, upconversion nanoparticles (UCNPs) and polymer dots (Pdots), have attracted extensive research interest in the field of biosensing in recent years. Benefiting from the ultra-small size, quantum confinement effect, excellent physical and chemical properties and good biocompatibility, 0D nanomaterials have shown great potential in ion detection, biomolecular recognition, disease diagnosis and pathogen detection. Here we first introduce the structures and properties of different 0D nanomaterials. On this basis, recent progress and application examples of 0D nanomaterials in the field of biosensing are discussed. In the last part, we summarize the research status of 0D nanomaterials in the field of biosensing and anticipate the development prospects and future challenges in this field.
Collapse
Affiliation(s)
| | | | - Ruizheng Liang
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, China
| | - Min Wei
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, China
| |
Collapse
|