1
|
Zhang P, Ding S, Peng K, He H, Wang D, Zhou R, Wang B, Guo J, Liu H, Huang X, Xie C, Liu H, Qiu B. Comparing the outcomes of MR-based versus CT-based tumor delineation in locally advanced non-small cell lung cancer treated with hypo-fractionated radiotherapy and concurrent chemotherapy. Transl Lung Cancer Res 2024; 13:2890-2902. [PMID: 39670014 PMCID: PMC11632429 DOI: 10.21037/tlcr-24-341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Accepted: 09/25/2024] [Indexed: 12/14/2024]
Abstract
Background Delineating gross tumor volume (GTV) using computed tomography (CT) imaging is the standard for lung cancer contouring, but discrepancies among observers compromise accuracy and reliability. Magnetic resonance imaging (MRI) provides superior soft-tissue resolution compared to CT, thus, we design this retrospective study to compare the treatment outcomes of magnetic resonance-based (MR-based) and CT-based tumor delineation in locally advanced non-small cell lung cancer (LA-NSCLC) patients treated with hypo-fractionated concurrent chemoradiotherapy (hypo-CCRT). Methods A total of 293 LA-NSCLC patients treated with hypo-CCRT from three trials between October 2015 and October 2020 were screened. Ninety patients with each MR-based delineation and CT-based delineation of the primary tumor were selected for analysis. In the MR-based delineation group, T1-enhanced MR images was rigidly registered with 10 respiratory phases of planning CT images, respectively. The primary tumors were contoured on each respiratory phase based on co-registered MRI. The locoregional progression-free survival (LPFS), progression-free survival (PFS), overall survival (OS) and toxicities in both groups were analyzed. Results The 2-year LPFS rate was 69.2% [95% confidence interval (CI): 59.6-80.2%] in the MR-based delineation group and 61.0% (95% CI: 50.9-73.0%) in the CT-based delineation group (P=0.37). There was no significant difference in median PFS (P=0.45) or OS (P=0.69) between the two groups. The MR-based delineation group had smaller planning target volume (186.1 vs. 315.3 cm3, P<0.001), lower incidences of ≥G2 pneumonitis (10% vs. 24.4%, P=0.001) and ≥G3 esophagitis (2.2% vs. 15.6%, P<0.001). In evaluating the patterns of recurrence, in-field recurrences were the dominant type in both groups (21 out of 27 patients in MR-based delineation group, 24 out of 32 patients in CT-based delineation group). Conclusions MR-based delineation in hypo-CCRT was feasible and achieved similar treatment efficacy to CT-based delineation. The use of MR imaging to reduce the target volume resulted in promising local control and lower incidence of radiation-induced toxicities.
Collapse
Affiliation(s)
- Pengxin Zhang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Shouliang Ding
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Kangqiang Peng
- Department of Medical Imaging, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Haoqiang He
- Department of Medical Imaging, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Daquan Wang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Rui Zhou
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Bin Wang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Jinyu Guo
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Hongdong Liu
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Xiaoyan Huang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Chuanmiao Xie
- Department of Medical Imaging, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Hui Liu
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Bo Qiu
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China
| |
Collapse
|
2
|
Bahloul MA, Jabeen S, Benoumhani S, Alsaleh HA, Belkhatir Z, Al‐Wabil A. Advancements in synthetic CT generation from MRI: A review of techniques, and trends in radiation therapy planning. J Appl Clin Med Phys 2024; 25:e14499. [PMID: 39325781 PMCID: PMC11539972 DOI: 10.1002/acm2.14499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 06/27/2024] [Accepted: 07/26/2024] [Indexed: 09/28/2024] Open
Abstract
BACKGROUND Magnetic resonance imaging (MRI) and Computed tomography (CT) are crucial imaging techniques in both diagnostic imaging and radiation therapy. MRI provides excellent soft tissue contrast but lacks the direct electron density data needed to calculate dosage. CT, on the other hand, remains the gold standard due to its accurate electron density information in radiation therapy planning (RTP) but it exposes patients to ionizing radiation. Synthetic CT (sCT) generation from MRI has been a focused study field in the last few years due to cost effectiveness as well as for the objective of minimizing side-effects of using more than one imaging modality for treatment simulation. It offers significant time and cost efficiencies, bypassing the complexities of co-registration, and potentially improving treatment accuracy by minimizing registration-related errors. In an effort to navigate the quickly developing field of precision medicine, this paper investigates recent advancements in sCT generation techniques, particularly those using machine learning (ML) and deep learning (DL). The review highlights the potential of these techniques to improve the efficiency and accuracy of sCT generation for use in RTP by improving patient care and reducing healthcare costs. The intricate web of sCT generation techniques is scrutinized critically, with clinical implications and technical underpinnings for enhanced patient care revealed. PURPOSE This review aims to provide an overview of the most recent advancements in sCT generation from MRI with a particular focus of its use within RTP, emphasizing on techniques, performance evaluation, clinical applications, future research trends and open challenges in the field. METHODS A thorough search strategy was employed to conduct a systematic literature review across major scientific databases. Focusing on the past decade's advancements, this review critically examines emerging approaches introduced from 2013 to 2023 for generating sCT from MRI, providing a comprehensive analysis of their methodologies, ultimately fostering further advancement in the field. This study highlighted significant contributions, identified challenges, and provided an overview of successes within RTP. Classifying the identified approaches, contrasting their advantages and disadvantages, and identifying broad trends were all part of the review's synthesis process. RESULTS The review identifies various sCT generation approaches, consisting atlas-based, segmentation-based, multi-modal fusion, hybrid approaches, ML and DL-based techniques. These approaches are evaluated for image quality, dosimetric accuracy, and clinical acceptability. They are used for MRI-only radiation treatment, adaptive radiotherapy, and MR/PET attenuation correction. The review also highlights the diversity of methodologies for sCT generation, each with its own advantages and limitations. Emerging trends incorporate the integration of advanced imaging modalities including various MRI sequences like Dixon sequences, T1-weighted (T1W), T2-weighted (T2W), as well as hybrid approaches for enhanced accuracy. CONCLUSIONS The study examines MRI-based sCT generation, to minimize negative effects of acquiring both modalities. The study reviews 2013-2023 studies on MRI to sCT generation methods, aiming to revolutionize RTP by reducing use of ionizing radiation and improving patient outcomes. The review provides insights for researchers and practitioners, emphasizing the need for standardized validation procedures and collaborative efforts to refine methods and address limitations. It anticipates the continued evolution of techniques to improve the precision of sCT in RTP.
Collapse
Affiliation(s)
- Mohamed A. Bahloul
- College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
- Translational Biomedical Engineering Research Lab, College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
| | - Saima Jabeen
- College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
- Translational Biomedical Engineering Research Lab, College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
- AI Research Center, College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
| | - Sara Benoumhani
- College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
- AI Research Center, College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
| | | | - Zehor Belkhatir
- School of Electronics and Computer ScienceUniversity of SouthamptonSouthamptonUK
| | - Areej Al‐Wabil
- College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
- AI Research Center, College of EngineeringAlfaisal UniversityRiyadhSaudi Arabia
| |
Collapse
|
3
|
Deng L, Chen S, Li Y, Huang S, Yang X, Wang J. Synthetic CT generation based on multi-sequence MR using CycleGAN for head and neck MRI-only planning. Biomed Eng Lett 2024; 14:1319-1333. [PMID: 39465105 PMCID: PMC11502648 DOI: 10.1007/s13534-024-00402-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 06/10/2024] [Accepted: 06/11/2024] [Indexed: 10/29/2024] Open
Abstract
The purpose of this study is to investigate the influence of different magnetic resonance (MR) sequences on the accuracy of generating computed tomography (sCT) images for nasopharyngeal carcinoma based on CycleGAN. In this study, 143 patients' head and neck MR sequence (T1, T2, T1C, and T1DIXONC) and CT imaging data were acquired. The generator and discriminator of CycleGAN are improved to achieve the purpose of balance confrontation, and a cyclic consistent structure control domain is proposed in terms of loss function. Four different single-sequence MR images and one multi-sequence MR image were used to evaluate the accuracy of sCT. During the model testing phase, five testing scenarios were employed to further assess the mean absolute error, peak signal-to-noise ratio, structural similarity index, and root mean square error between the actual CT images and the sCT images generated by different models. T1 sequence-based sCT achieved better results in single-sequence MR-based sCT. Multi-sequence MR-based sCT achieved better results with T1 sequence-based sCT in terms of evaluation metrics. For metrological evaluation, the global gamma passage rate of sCT based on sequence MR was greater than 95% at 3%/3 mm, except for sCT based on T2 sequence MR. We developed a CycleGAN method to synthesize CT using different MR sequences, this method shows encouraging potential for dosimetric evaluation.
Collapse
Affiliation(s)
- Liwei Deng
- School of Computer Science and Technology, Harbin University of Science and Technology, Harbin, 150080 Heilongjiang China
- Heilongjiang Provincial Key Laboratory of Complex Intelligent System and Integration, School of Automation, Harbin University of Science and Technology, Harbin, 150080 Heilongjiang China
| | - Songyu Chen
- School of Computer Science and Technology, Harbin University of Science and Technology, Harbin, 150080 Heilongjiang China
| | - Yunfa Li
- Heilongjiang Provincial Key Laboratory of Complex Intelligent System and Integration, School of Automation, Harbin University of Science and Technology, Harbin, 150080 Heilongjiang China
| | - Sijuan Huang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-Sen University Cancer Center, Guangzhou, 510060 Guangdong China
| | - Xin Yang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-Sen University Cancer Center, Guangzhou, 510060 Guangdong China
| | - Jing Wang
- Institute for Brain Research and Rehabilitation, South China Normal University, Guangzhou, 510631 China
| |
Collapse
|
4
|
Fok WYR, Fieselmann A, Huemmer C, Biniazan R, Beister M, Geiger B, Kappler S, Saalfeld S. Adversarial robustness improvement for X-ray bone segmentation using synthetic data created from computed tomography scans. Sci Rep 2024; 14:25813. [PMID: 39468116 PMCID: PMC11519576 DOI: 10.1038/s41598-024-73363-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 09/17/2024] [Indexed: 10/30/2024] Open
Abstract
Deep learning-based image analysis offers great potential in clinical practice. However, it faces mainly two challenges: scarcity of large-scale annotated clinical data for training and susceptibility to adversarial data in inference. As an example, an artificial intelligence (AI) system could check patient positioning, by segmenting and evaluating relative positions of anatomical structures in medical images. Nevertheless, data to train such AI system might be highly imbalanced with mostly well-positioned images being available. Thus, we propose the use of synthetic X-ray images and annotation masks forward projected from 3D photon-counting CT volumes to create realistic non-optimally positioned X-ray images for training. An open-source model (TotalSegmentator) was used to annotate the clavicles in 3D CT volumes. We evaluated model robustness with respect to the internal (simulated) patient rotation α on real-data-trained models and real&synthetic-data-trained models. Our results showed that real&synthetic- data-trained models have Dice score percentage improvements of 3% to 15% across different α groups compared to the real-data-trained model. Therefore, we demonstrated that synthetic data could be supplementary used to train and enrich heavily underrepresented conditions to increase model robustness.
Collapse
Affiliation(s)
- Wai Yan Ryana Fok
- Faculty of Computer Science, Otto-von-Guericke-University Magdeburg, 39106, Magdeburg, Germany.
- X-ray Products, Siemens Healthineers AG, 91301, Forchheim, Germany.
| | | | | | - Ramyar Biniazan
- X-ray Products, Siemens Healthineers AG, 91301, Forchheim, Germany
| | - Marcel Beister
- X-ray Products, Siemens Healthineers AG, 91301, Forchheim, Germany
| | - Bernhard Geiger
- X-ray Products, Siemens Healthineers AG, 91301, Forchheim, Germany
| | - Steffen Kappler
- X-ray Products, Siemens Healthineers AG, 91301, Forchheim, Germany
| | - Sylvia Saalfeld
- Faculty of Computer Science, Otto-von-Guericke-University Magdeburg, 39106, Magdeburg, Germany
- Institute for Medical Informatics and Statistics, University Hospital Schleswig-Holstein Campus Kiel, 24105, Kiel, Germany
| |
Collapse
|
5
|
Chetty IJ, Cai B, Chuong MD, Dawes SL, Hall WA, Helms AR, Kirby S, Laugeman E, Mierzwa M, Pursley J, Ray X, Subashi E, Henke LE. Quality and Safety Considerations for Adaptive Radiation Therapy: An ASTRO White Paper. Int J Radiat Oncol Biol Phys 2024:S0360-3016(24)03474-6. [PMID: 39424080 DOI: 10.1016/j.ijrobp.2024.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2024] [Revised: 09/06/2024] [Accepted: 10/06/2024] [Indexed: 10/21/2024]
Abstract
PURPOSE Adaptive radiation therapy (ART) is the latest topic in a series of white papers published by the American Society for Radiation Oncology addressing quality processes and patient safety. ART widens the therapeutic index by improving the precision of radiation dose to targets, allowing for dose escalation and/or minimization of dose to normal tissue. ART is performed via offline or online methods; offline ART is the process of replanning a patient's treatment plan between fractions, whereas online ART involves plan adjustment with the patient on the treatment table. This is achieved with in-room imaging capable of assessing anatomic changes and the ability to reoptimize the treatment plan rapidly during the treatment session. Although ART has occurred in its simplest forms in clinical practice for decades, recent technological developments have enabled more clinical applications of ART. With increased clinical prevalence, compressed timelines, and the associated complexity of ART, quality and safety considerations are an important focus area. METHODS The American Society for Radiation Oncology convened an interdisciplinary task force to provide expert consensus on key workflows and processes for ART. Recommendations were created using a consensus-building methodology, and task force members indicated their level of agreement based on a 5-point Likert scale, from "strongly agree" to "strongly disagree." A prespecified threshold of ≥75% of raters selecting "strongly agree" or "agree" indicated consensus. Content not meeting this threshold was removed or revised. SUMMARY Establishing and maintaining an adaptive program requires a team-based approach, appropriately trained and credentialed specialists, significant resources, specialized technology, and implementation time. A comprehensive quality assurance program must be developed, using established guidance, to make sure all forms of ART are performed in a safe and effective manner. Patient safety when delivering ART is everyone's responsibility, and professional organizations, regulators, vendors, and end users must demonstrate a clear commitment to working together to deliver the highest levels of quality and safety.
Collapse
Affiliation(s)
- Indrin J Chetty
- Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California
| | - Bin Cai
- Department of Radiation Oncology, University of Texas Southwestern, Dallas, Texas
| | - Michael D Chuong
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
| | | | - William A Hall
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Amanda R Helms
- American Society for Radiation Oncology, Arlington, Virginia
| | - Suzanne Kirby
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia
| | - Eric Laugeman
- Department of Radiation Oncology, Washington University in St Louis, St Louis, Missouri
| | - Michelle Mierzwa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Jennifer Pursley
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
| | - Xenia Ray
- Department of Radiation Medicine & Applied Sciences, University of California, San Diego, California
| | - Ergys Subashi
- Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Lauren E Henke
- Department of Radiation Oncology, Case Western University Hospitals, Cleveland, Ohio
| |
Collapse
|
6
|
Rippke C, Renkamp CK, Stahl-Arnsberger C, Miltner A, Buchele C, Hörner-Rieber J, Ristau J, Debus J, Alber M, Klüter S. A body mass index-based method for "MR-only" abdominal MR-guided adaptive radiotherapy. Z Med Phys 2024; 34:456-467. [PMID: 36759229 PMCID: PMC11384073 DOI: 10.1016/j.zemedi.2022.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 12/08/2022] [Accepted: 12/09/2022] [Indexed: 02/10/2023]
Abstract
PURPOSE Dose calculation for MR-guided radiotherapy (MRgRT) at the 0.35 T MR-Linac is currently based on deformation of planning CTs (defCT) acquired for each patient. We present a simple and robust bulk density overwrite synthetic CT (sCT) method for abdominal treatments in order to streamline clinical workflows. METHOD Fifty-six abdominal patient treatment plans were retrospectively evaluated. All patients had been treated at the MR-Linac using MR datasets for treatment planning and plan adaption and defCT for dose calculation. Bulk density CTs (4M-sCT) were generated from MR images with four material compartments (bone, lung, air, soft tissue). The relative electron densities (RED) for bone and lung were extracted from contoured CT structure average REDs. For soft tissue, a correlation between BMI and RED was evaluated. Dose was recalculated on 4M-sCT and compared to dose distributions on defCTs assessing dose differences in the PTV and organs at risk (OAR). RESULTS Mean RED of bone was 1.17 ± 0.02, mean RED of lung 0.17 ± 0.05. The correlation between BMI and RED for soft tissue was statistically significant (p < 0.01). PTV dose differences between 4M-sCT and defCT were Dmean: -0.4 ± 1.0%, D1%: -0.3 ± 1.1% and D95%: -0.5 ± 1.0%. OARs showed D2%: -0.3 ± 1.9% and Dmean: -0.1 ± 1.4% differences. Local 3D gamma index pass rates (2%/2mm) between dose calculated using 4M-sCT and defCT were 96.8 ± 2.6% (range 89.9-99.6%). CONCLUSION The presented method for sCT generation enables precise dose calculation for MR-only abdominal MRgRT.
Collapse
Affiliation(s)
- Carolin Rippke
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany; Medical Faculty, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany.
| | - C Katharina Renkamp
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
| | - Christiane Stahl-Arnsberger
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Annette Miltner
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Carolin Buchele
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany; Medical Faculty, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany
| | - Juliane Hörner-Rieber
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany; Medical Faculty, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany; Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Im Neuenheimer Feld 460, 69120 Heidelberg, Germany; German Cancer Consortium (DKTK), Core-center Heidelberg, Heidelberg, Germany
| | - Jonas Ristau
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany; Medical Faculty, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany; Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; National Center for Tumor Diseases (NCT), Im Neuenheimer Feld 460, 69120 Heidelberg, Germany; Heidelberg Ion-Beam Therapy Center (HIT), Im Neuenheimer Feld 450, 69120 Heidelberg, Germany; German Cancer Consortium (DKTK), Core-center Heidelberg, Heidelberg, Germany
| | - Markus Alber
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany; Medical Faculty, University of Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany
| | - Sebastian Klüter
- Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany; Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Oncology (NCRO), Heidelberg, Germany.
| |
Collapse
|
7
|
Garg P, Singhal S, Kulkarni P, Horne D, Malhotra J, Salgia R, Singhal SS. Advances in Non-Small Cell Lung Cancer: Current Insights and Future Directions. J Clin Med 2024; 13:4189. [PMID: 39064229 PMCID: PMC11278207 DOI: 10.3390/jcm13144189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 07/11/2024] [Accepted: 07/17/2024] [Indexed: 07/28/2024] Open
Abstract
The leading cause of cancer deaths worldwide is attributed to non-small cell lung cancer (NSCLC), necessitating a continual focus on improving the diagnosis and treatment of this disease. In this review, the latest breakthroughs and emerging trends in managing NSCLC are highlighted. Major advancements in diagnostic methods, including better imaging technologies and the utilization of molecular biomarkers, are discussed. These advancements have greatly enhanced early detection and personalized treatment plans. Significant improvements in patient outcomes have been achieved by new targeted therapies and immunotherapies, providing new hope for individuals with advanced NSCLC. This review discusses the persistent challenges in accessing advanced treatments and their associated costs despite recent progress. Promising research into new therapies, such as CAR-T cell therapy and oncolytic viruses, which could further revolutionize NSCLC treatment, is also highlighted. This review aims to inform and inspire continued efforts to improve outcomes for NSCLC patients globally, by offering a comprehensive overview of the current state of NSCLC treatment and future possibilities.
Collapse
Affiliation(s)
- Pankaj Garg
- Department of Chemistry, GLA University, Mathura 281406, Uttar Pradesh, India
| | - Sulabh Singhal
- Department of Internal Medicine, Drexel University College of Medicine, Philadelphia, PA 19104, USA
| | - Prakash Kulkarni
- Departments of Medical Oncology & Therapeutics Research, Beckman Research Institute of City of Hope, Comprehensive Cancer Center and National Medical Center, Duarte, CA 91010, USA
| | - David Horne
- Departments of Molecular Medicine, Beckman Research Institute of City of Hope, Comprehensive Cancer Center and National Medical Center, Duarte, CA 91010, USA
| | - Jyoti Malhotra
- Departments of Medical Oncology & Therapeutics Research, Beckman Research Institute of City of Hope, Comprehensive Cancer Center and National Medical Center, Duarte, CA 91010, USA
| | - Ravi Salgia
- Departments of Medical Oncology & Therapeutics Research, Beckman Research Institute of City of Hope, Comprehensive Cancer Center and National Medical Center, Duarte, CA 91010, USA
| | - Sharad S. Singhal
- Departments of Medical Oncology & Therapeutics Research, Beckman Research Institute of City of Hope, Comprehensive Cancer Center and National Medical Center, Duarte, CA 91010, USA
| |
Collapse
|
8
|
Chaknam K, Worapruekjaru L, Suphaphong S, Stansook N, Sodkokkruad P, Asavaphatiboon S. Impact Assessment of Systemic Geometric Distortion in 1.5T Magnetic Resonance Imaging Simulation through Three-dimensional Geometric Distortion Phantom on Dosimetric Accuracy for Magnetic Resonance Imaging-only Prostate Treatment Planning. J Med Phys 2024; 49:356-362. [PMID: 39526153 PMCID: PMC11548076 DOI: 10.4103/jmp.jmp_62_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 04/09/2024] [Accepted: 04/24/2024] [Indexed: 11/16/2024] Open
Abstract
Aims Magnetic resonance imaging (MRI)-only radiotherapy has emerged as a solution to address registration errors that can lead to missed dose delivery. However, the presence of systemic geometric distortion (SGD) stemming from gradient nonlinearity (GNL) and inhomogeneity of the main magnetic field (B0) necessitates consideration. This study aimed to quantitatively assess residual SGD in 1.5T MRI simulation using a three-dimensional (3D) geometric distortion phantom and evaluate its impact on dosimetric accuracy for retrospective prostate cancer patients. Materials and Methods Ten retrospective cases of prostate cancer patients treated with volumetric modulated arc radiotherapy (VMAT) were randomly selected. A geometric distortion phantom was scanned on a 1.5T MRI simulation using a 3D T1 volumetric interpolated breath-hold examination sequence, varying bandwidth (BW), and two-phase-encoding directions. Distortion maps were generated and applied to the original computed tomography (oriCT) plan to create a distorted computed tomography plan (dCT), and a dice similarity coefficient (DSC) was observed. Dosimetric accuracy was evaluated by recalculating radiation dose for dCT plans using identical beam parameters as oriCT. Results The SGD increased with distance from the isocenter in all series. DSC exceeded 0.95 for all plans except the rectum. Regarding GNL's impact on dosimetric accuracy, most mean percentage errors for clinical target volume, planning target volume, and both femurs were under 2% in all plans, except for the bladder and rectum. Conclusion SGD pre-evaluation is crucial and should be incorporated into a quality assurance program to ensure effective MRI-simulation performance before MRI-only treatment planning for prostate cancer.
Collapse
Affiliation(s)
- Korawig Chaknam
- Division of Diagnostic Radiology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Ladawan Worapruekjaru
- Division of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Sithiphong Suphaphong
- Division of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Nualjun Stansook
- Division of Radiation Oncology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Prapa Sodkokkruad
- Division of Diagnostic Radiology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | - Sawwanee Asavaphatiboon
- Division of Diagnostic Radiology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
9
|
Wu K, Zhu X, Anderson SW, Zhang X. Wireless, customizable coaxially shielded coils for magnetic resonance imaging. SCIENCE ADVANCES 2024; 10:eadn5195. [PMID: 38865448 PMCID: PMC11168459 DOI: 10.1126/sciadv.adn5195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 05/08/2024] [Indexed: 06/14/2024]
Abstract
Anatomy-specific radio frequency receive coil arrays routinely adopted in magnetic resonance imaging (MRI) for signal acquisition are commonly burdened by their bulky, fixed, and rigid configurations, which may impose patient discomfort, bothersome positioning, and suboptimal sensitivity in certain situations. Herein, leveraging coaxial cables' inherent flexibility and electric field confining property, we present wireless, ultralightweight, coaxially shielded, passive detuning MRI coils achieving a signal-to-noise ratio comparable to or surpassing that of commercially available cutting-edge receive coil arrays with the potential for improved patient comfort, ease of implementation, and substantially reduced costs. The proposed coils demonstrate versatility by functioning both independently in form-fitting configurations, closely adapting to relatively small anatomical sites, and collectively by inductively coupling together as metamaterials, allowing for extension of the field of view of their coverage to encompass larger anatomical regions without compromising coil sensitivity. The wireless, coaxially shielded MRI coils reported herein pave the way toward next-generation MRI coils.
Collapse
Affiliation(s)
- Ke Wu
- Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA
- Photonics Center, Boston University, Boston, MA 02215, USA
| | - Xia Zhu
- Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA
- Photonics Center, Boston University, Boston, MA 02215, USA
| | - Stephan W. Anderson
- Photonics Center, Boston University, Boston, MA 02215, USA
- Boston University Chobanian and Avedisian School of Medicine, Boston, MA 02118, USA
| | - Xin Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA
- Photonics Center, Boston University, Boston, MA 02215, USA
| |
Collapse
|
10
|
Gao Y, Chang CW, Mandava S, Marants R, Scholey JE, Goette M, Lei Y, Mao H, Bradley JD, Liu T, Zhou J, Sudhyadhom A, Yang X. MRI-only based material mass density and relative stopping power estimation via deep learning for proton therapy: a preliminary study. Sci Rep 2024; 14:11166. [PMID: 38750148 PMCID: PMC11096170 DOI: 10.1038/s41598-024-61869-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 05/10/2024] [Indexed: 05/18/2024] Open
Abstract
Magnetic Resonance Imaging (MRI) is increasingly being used in treatment planning due to its superior soft tissue contrast, which is useful for tumor and soft tissue delineation compared to computed tomography (CT). However, MRI cannot directly provide mass density or relative stopping power (RSP) maps, which are required for calculating proton radiotherapy doses. Therefore, the integration of artificial intelligence (AI) into MRI-based treatment planning to estimate mass density and RSP directly from MRI has generated significant interest. A deep learning (DL) based framework was developed to establish a voxel-wise correlation between MR images and mass density as well as RSP. To facilitate the study, five tissue substitute phantoms were created, representing different tissues such as skin, muscle, adipose tissue, 45% hydroxyapatite (HA), and spongiosa bone. The composition of these phantoms was based on information from ICRP reports. Additionally, two animal tissue phantoms, simulating pig brain and liver, were prepared for DL training purposes. The phantom study involved the development of two DL models. The first model utilized clinical T1 and T2 MRI scans as input, while the second model incorporated zero echo time (ZTE) MRI scans. In the patient application study, two more DL models were trained: one using T1 and T2 MRI scans as input, and another model incorporating synthetic dual-energy computed tomography (sDECT) images to provide accurate bone tissue information. The DECT empirical model was used as a reference to evaluate the proposed models in both phantom and patient application studies. The DECT empirical model was selected as the reference for evaluating the proposed models in both phantom and patient application studies. In the phantom study, the DL model based on T1, and T2 MRI scans demonstrated higher accuracy in estimating mass density and RSP for skin, muscle, adipose tissue, brain, and liver. The mean absolute percentage errors (MAPE) were 0.42%, 0.14%, 0.19%, 0.78%, and 0.26% for mass density, and 0.30%, 0.11%, 0.16%, 0.61%, and 0.23% for RSP, respectively. The DL model incorporating ZTE MRI further improved the accuracy of mass density and RSP estimation for 45% HA and spongiosa bone, with MAPE values of 0.23% and 0.09% for mass density, and 0.19% and 0.07% for RSP, respectively. These results demonstrate the feasibility of using an MRI-only approach combined with DL methods for mass density and RSP estimation in proton therapy treatment planning. By employing this approach, it is possible to obtain the necessary information for proton radiotherapy directly from MRI scans, eliminating the need for additional imaging modalities.
Collapse
Affiliation(s)
- Yuan Gao
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30308, USA
| | - Chih-Wei Chang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30308, USA
| | | | - Raanan Marants
- Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women's Hospital, and Harvard Medical School, Boston, Massachusetts, USA
| | - Jessica E Scholey
- Department of Radiation Oncology, The University of California, San Francisco, CA, 94143, USA
| | - Matthew Goette
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30308, USA
| | - Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30308, USA
| | - Hui Mao
- Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA, USA
| | - Jeffrey D Bradley
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30308, USA
| | - Tian Liu
- Radiation Oncology, Mount Sinai Medical Center, New York, NY, USA
| | - Jun Zhou
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30308, USA
| | - Atchar Sudhyadhom
- Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women's Hospital, and Harvard Medical School, Boston, Massachusetts, USA.
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30308, USA.
| |
Collapse
|
11
|
He Q, Summerfield N, Dong M, Glide-Hurst C. MODALITY-AGNOSTIC LEARNING FOR MEDICAL IMAGE SEGMENTATION USING MULTI-MODALITY SELF-DISTILLATION. PROCEEDINGS. IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING 2024; 2024:10.1109/isbi56570.2024.10635881. [PMID: 39735423 PMCID: PMC11673955 DOI: 10.1109/isbi56570.2024.10635881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2024]
Abstract
In medical image segmentation, although multi-modality training is possible, clinical translation is challenged by the limited availability of all image types for a given patient. Different from typical segmentation models, modality-agnostic (MAG) learning trains a single model based on all available modalities but remains input-agnostic, allowing a single model to produce accurate segmentation given any modality combinations. In this paper, we propose a novel frame-work, MAG learning through Multi-modality Self-distillation (MAG-MS), for medical image segmentation. MAG-MS distills knowledge from the fusion of multiple modalities and applies it to enhance representation learning for individual modalities. This makes it an adaptable and efficient solution for handling limited modalities during testing scenarios. Our extensive experiments on benchmark datasets demonstrate its superior segmentation accuracy, MAG robustness, and efficiency than the current state-of-the-art methods.
Collapse
Affiliation(s)
- Qisheng He
- Department of Computer Science, Wayne State University, Detroit, MI, USA
| | - Nicholas Summerfield
- Department of Human Oncology, University of Wisconsin-Madison, Madison, WI, USA
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Ming Dong
- Department of Computer Science, Wayne State University, Detroit, MI, USA
| | - Carri Glide-Hurst
- Department of Human Oncology, University of Wisconsin-Madison, Madison, WI, USA
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
12
|
Kim H, Yoo SK, Kim JS, Kim YT, Lee JW, Kim C, Hong CS, Lee H, Han MC, Kim DW, Kim SY, Kim TM, Kim WH, Kong J, Kim YB. Clinical feasibility of deep learning-based synthetic CT images from T2-weighted MR images for cervical cancer patients compared to MRCAT. Sci Rep 2024; 14:8504. [PMID: 38605094 PMCID: PMC11009270 DOI: 10.1038/s41598-024-59014-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 04/05/2024] [Indexed: 04/13/2024] Open
Abstract
This work aims to investigate the clinical feasibility of deep learning-based synthetic CT images for cervix cancer, comparing them to MR for calculating attenuation (MRCAT). Patient cohort with 50 pairs of T2-weighted MR and CT images from cervical cancer patients was split into 40 for training and 10 for testing phases. We conducted deformable image registration and Nyul intensity normalization for MR images to maximize the similarity between MR and CT images as a preprocessing step. The processed images were plugged into a deep learning model, generative adversarial network. To prove clinical feasibility, we assessed the accuracy of synthetic CT images in image similarity using structural similarity (SSIM) and mean-absolute-error (MAE) and dosimetry similarity using gamma passing rate (GPR). Dose calculation was performed on the true and synthetic CT images with a commercial Monte Carlo algorithm. Synthetic CT images generated by deep learning outperformed MRCAT images in image similarity by 1.5% in SSIM, and 18.5 HU in MAE. In dosimetry, the DL-based synthetic CT images achieved 98.71% and 96.39% in the GPR at 1% and 1 mm criterion with 10% and 60% cut-off values of the prescription dose, which were 0.9% and 5.1% greater GPRs over MRCAT images.
Collapse
Affiliation(s)
- Hojin Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Sang Kyun Yoo
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Jin Sung Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Yong Tae Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Jai Wo Lee
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Changhwan Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Chae-Seon Hong
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Ho Lee
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Min Cheol Han
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Dong Wook Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Se Young Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Tae Min Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Woo Hyoung Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Jayoung Kong
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Yong Bae Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul, 03722, Korea.
| |
Collapse
|
13
|
Emin S, Rossi E, Myrvold Rooth E, Dorniok T, Hedman M, Gagliardi G, Villegas F. Clinical implementation of a commercial synthetic computed tomography solution for radiotherapy treatment of glioblastoma. Phys Imaging Radiat Oncol 2024; 30:100589. [PMID: 38818305 PMCID: PMC11137592 DOI: 10.1016/j.phro.2024.100589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 05/12/2024] [Accepted: 05/13/2024] [Indexed: 06/01/2024] Open
Abstract
Background and Purpose Magnetic resonance (MR)-only radiotherapy (RT) workflow eliminates uncertainties due to computed tomography (CT)-MR image registration, by using synthetic CT (sCT) images generated from MR. This study describes the clinical implementation process, from retrospective commissioning to prospective validation stage of a commercial artificial intelligence (AI)-based sCT product. Evaluation of the dosimetric performance of the sCT is presented, with emphasis on the impact of voxel size differences between image modalities. Materials and methods sCT performance was assessed in glioblastoma RT planning. Dose differences for 30 patients in both commissioning and validation cohorts were calculated at various dose-volume-histogram (DVH) points for target and organs-at-risk (OAR). A gamma analysis was conducted on regridded image plans. Quality assurance (QA) guidelines were established based on commissioning phase results. Results Mean dose difference to target structures was found to be within ± 0.7 % regardless of image resolution and cohort. OARs' mean dose differences were within ± 1.3 % for plans calculated on regridded images for both cohorts, while differences were higher for plans with original voxel size, reaching up to -4.2 % for chiasma D2% in the commissioning cohort. Gamma passing rates for the brain structure using the criteria 1 %/1mm, 2 %/2mm and 3 %/3mm were 93.6 %/99.8 %/100 % and 96.6 %/99.9 %/100 % for commissioning and validation cohorts, respectively. Conclusions Dosimetric outcomes in both commissioning and validation stages confirmed sCT's equivalence to CT. The large patient cohort in this study aided in establishing a robust QA program for the MR-only workflow, now applied in glioblastoma RT at our center.
Collapse
Affiliation(s)
- Sevgi Emin
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
| | - Elia Rossi
- Department of Radiation Oncology, Karolinska University Hospital, 171 76 Stockholm, Sweden
| | | | - Torsten Dorniok
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
| | - Mattias Hedman
- Department of Radiation Oncology, Karolinska University Hospital, 171 76 Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institute, 171 77 Stockholm, Sweden
| | - Giovanna Gagliardi
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institute, 171 77 Stockholm, Sweden
| | - Fernanda Villegas
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76 Stockholm, Sweden
- Department of Oncology-Pathology, Karolinska Institute, 171 77 Stockholm, Sweden
| |
Collapse
|
14
|
Sherwani MK, Gopalakrishnan S. A systematic literature review: deep learning techniques for synthetic medical image generation and their applications in radiotherapy. FRONTIERS IN RADIOLOGY 2024; 4:1385742. [PMID: 38601888 PMCID: PMC11004271 DOI: 10.3389/fradi.2024.1385742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 03/11/2024] [Indexed: 04/12/2024]
Abstract
The aim of this systematic review is to determine whether Deep Learning (DL) algorithms can provide a clinically feasible alternative to classic algorithms for synthetic Computer Tomography (sCT). The following categories are presented in this study: ∙ MR-based treatment planning and synthetic CT generation techniques. ∙ Generation of synthetic CT images based on Cone Beam CT images. ∙ Low-dose CT to High-dose CT generation. ∙ Attenuation correction for PET images. To perform appropriate database searches, we reviewed journal articles published between January 2018 and June 2023. Current methodology, study strategies, and results with relevant clinical applications were analyzed as we outlined the state-of-the-art of deep learning based approaches to inter-modality and intra-modality image synthesis. This was accomplished by contrasting the provided methodologies with traditional research approaches. The key contributions of each category were highlighted, specific challenges were identified, and accomplishments were summarized. As a final step, the statistics of all the cited works from various aspects were analyzed, which revealed that DL-based sCTs have achieved considerable popularity, while also showing the potential of this technology. In order to assess the clinical readiness of the presented methods, we examined the current status of DL-based sCT generation.
Collapse
Affiliation(s)
- Moiz Khan Sherwani
- Section for Evolutionary Hologenomics, Globe Institute, University of Copenhagen, Copenhagen, Denmark
| | | |
Collapse
|
15
|
Tseng CL, Zeng KL, Mellon EA, Soltys SG, Ruschin M, Lau AZ, Lutsik NS, Chan RW, Detsky J, Stewart J, Maralani PJ, Sahgal A. Evolving concepts in margin strategies and adaptive radiotherapy for glioblastoma: A new future is on the horizon. Neuro Oncol 2024; 26:S3-S16. [PMID: 38437669 PMCID: PMC10911794 DOI: 10.1093/neuonc/noad258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2024] Open
Abstract
Chemoradiotherapy is the standard treatment after maximal safe resection for glioblastoma (GBM). Despite advances in molecular profiling, surgical techniques, and neuro-imaging, there have been no major breakthroughs in radiotherapy (RT) volumes in decades. Although the majority of recurrences occur within the original gross tumor volume (GTV), treatment of a clinical target volume (CTV) ranging from 1.5 to 3.0 cm beyond the GTV remains the standard of care. Over the past 15 years, the incorporation of standard and functional MRI sequences into the treatment workflow has become a routine practice with increasing adoption of MR simulators, and new integrated MR-Linac technologies allowing for daily pre-, intra- and post-treatment MR imaging. There is now unprecedented ability to understand the tumor dynamics and biology of GBM during RT, and safe CTV margin reduction is being investigated with the goal of improving the therapeutic ratio. The purpose of this review is to discuss margin strategies and the potential for adaptive RT for GBM, with a focus on the challenges and opportunities associated with both online and offline adaptive workflows. Lastly, opportunities to biologically guide adaptive RT using non-invasive imaging biomarkers and the potential to define appropriate volumes for dose modification will be discussed.
Collapse
Affiliation(s)
- Chia-Lin Tseng
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - K Liang Zeng
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
- Department of Radiation Oncology, Simcoe Muskoka Regional Cancer Program, Royal Victoria Regional Health Centre, University of Toronto, Toronto, Ontario, Canada
| | - Eric A Mellon
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami, Miami, Florida, USA
| | - Scott G Soltys
- Department of Radiation Oncology, Stanford University, Stanford, California, USA
| | - Mark Ruschin
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Angus Z Lau
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada
- Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Natalia S Lutsik
- Department of Radiation Oncology, Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami, Miami, Florida, USA
| | - Rachel W Chan
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Jay Detsky
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - James Stewart
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Pejman J Maralani
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Arjun Sahgal
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
16
|
Sun H, Yang Z, Zhu J, Li J, Gong J, Chen L, Wang Z, Yin Y, Ren G, Cai J, Zhao L. Pseudo-medical image-guided technology based on 'CBCT-only' mode in esophageal cancer radiotherapy. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 245:108007. [PMID: 38241802 DOI: 10.1016/j.cmpb.2024.108007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 11/03/2023] [Accepted: 01/03/2024] [Indexed: 01/21/2024]
Abstract
Purpose To minimize the various errors introduced by image-guided radiotherapy (IGRT) in the application of esophageal cancer treatment, this study proposes a novel technique based on the 'CBCT-only' mode of pseudo-medical image guidance. Methods The framework of this technology consists of two pseudo-medical image synthesis models in the CBCT→CT and the CT→PET direction. The former utilizes a dual-domain parallel deep learning model called AWM-PNet, which incorporates attention waning mechanisms. This model effectively suppresses artifacts in CBCT images in both the sinogram and spatial domains while efficiently capturing important image features and contextual information. The latter leverages tumor location and shape information provided by clinical experts. It introduces a PRAM-GAN model based on a prior region aware mechanism to establish a non-linear mapping relationship between CT and PET image domains. As a result, it enables the generation of pseudo-PET images that meet the clinical requirements for radiotherapy. Results The NRMSE and multi-scale SSIM (MS-SSIM) were utilized to evaluate the test set, and the results were presented as median values with lower quartile and upper quartile ranges. For the AWM-PNet model, the NRMSE and MS-SSIM values were 0.0218 (0.0143, 0.0255) and 0.9325 (0.9141, 0.9410), respectively. The PRAM-GAN model produced NRMSE and MS-SSIM values of 0.0404 (0.0356, 0.0476) and 0.9154 (0.8971, 0.9294), respectively. Statistical analysis revealed significant differences (p < 0.05) between these models and others. The numerical results of dose metrics, including D98 %, Dmean, and D2 %, validated the accuracy of HU values in the pseudo-CT images synthesized by the AWM-PNet. Furthermore, the Dice coefficient results confirmed statistically significant differences (p < 0.05) in GTV delineation between the pseudo-PET images synthesized using the PRAM-GAN model and other compared methods. Conclusion The AWM-PNet and PRAM-GAN models have the capability to generate accurate pseudo-CT and pseudo-PET images, respectively. The pseudo-image-guided technique based on the 'CBCT-only' mode shows promising prospects for application in esophageal cancer radiotherapy.
Collapse
Affiliation(s)
- Hongfei Sun
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Zhi Yang
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Jiarui Zhu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Jie Li
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Jie Gong
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Liting Chen
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Zhongfei Wang
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Yutian Yin
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | - Ge Ren
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China.
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China.
| | - Lina Zhao
- Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi'an, China.
| |
Collapse
|
17
|
Rossi E, Emin S, Gubanski M, Gagliardi G, Hedman M, Villegas F. Contouring practices and artefact management within a synthetic CT-based radiotherapy workflow for the central nervous system. Radiat Oncol 2024; 19:27. [PMID: 38424642 PMCID: PMC11320867 DOI: 10.1186/s13014-024-02422-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 02/19/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND The incorporation of magnetic resonance (MR) imaging in radiotherapy (RT) workflows improves contouring precision, yet it introduces geometrical uncertainties when registered with computed tomography (CT) scans. Synthetic CT (sCT) images could minimize these uncertainties and streamline the RT workflow. This study aims to compare the contouring capabilities of sCT images with conventional CT-based/MR-assisted RT workflows, with an emphasis on managing artefacts caused by surgical fixation devices (SFDs). METHODS The study comprised a commissioning cohort of 100 patients with cranial tumors treated using a conventional CT-based/MR-assisted RT workflow and a validation cohort of 30 patients with grade IV glioblastomas treated using an MR-only workflow. A CE-marked artificial-intelligence-based sCT product was utilized. The delineation accuracy comparison was performed using dice similarity coefficient (DSC) and average Hausdorff distance (AHD). Artefacts within the commissioning cohort were visually inspected, classified and an estimation of thickness was derived using Hausdorff distance (HD). For the validation cohort, boolean operators were used to extract artefact volumes adjacent to the target and contrasted to the planning treatment volume. RESULTS The combination of high DSC (0.94) and low AHD (0.04 mm) indicates equal target delineation capacity between sCT images and conventional CT scans. However, the results for organs at risk delineation were less consistent, likely because of voxel size differences between sCT images and CT scans and absence of standardized delineation routines. Artefacts observed in sCT images appeared as enhancements of cranial bone. When close to the target, they could affect its definition. Therefore, in the validation cohort the clinical target volume (CTV) was expanded towards the bone by 3.5 mm, as estimated by HD analysis. Subsequent analysis on cone-beam CT scans showed that the CTV adjustment was enough to provide acceptable target coverage. CONCLUSION The tested sCT product performed on par with conventional CT in terms of contouring capability. Additionally, this study provides both the first comprehensive classification of metal artefacts on a sCT product and a novel method to assess the clinical impact of artefacts caused by SFDs on target delineation. This methodology encourages similar analysis for other sCT products.
Collapse
Affiliation(s)
- Elia Rossi
- Department of Radiation Oncology, Karolinska University Hospital, Solna, Sweden
| | - Sevgi Emin
- Radiotherapy Physics and Engineering, Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden
| | - Michael Gubanski
- Department of Radiation Oncology, Karolinska University Hospital, Solna, Sweden
- Department of Oncology-Pathology, Karolinska Institutet, Solna, Sweden
| | - Giovanna Gagliardi
- Radiotherapy Physics and Engineering, Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden
- Department of Oncology-Pathology, Karolinska Institutet, Solna, Sweden
| | - Mattias Hedman
- Department of Radiation Oncology, Karolinska University Hospital, Solna, Sweden
- Department of Oncology-Pathology, Karolinska Institutet, Solna, Sweden
| | - Fernanda Villegas
- Radiotherapy Physics and Engineering, Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.
- Department of Oncology-Pathology, Karolinska Institutet, Solna, Sweden.
| |
Collapse
|
18
|
Chang CW, Peng J, Safari M, Salari E, Pan S, Roper J, Qiu RLJ, Gao Y, Shu HK, Mao H, Yang X. High-resolution MRI synthesis using a data-driven framework with denoising diffusion probabilistic modeling. Phys Med Biol 2024; 69:045001. [PMID: 38241726 PMCID: PMC10839468 DOI: 10.1088/1361-6560/ad209c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/08/2024] [Accepted: 01/19/2024] [Indexed: 01/21/2024]
Abstract
Objective. High-resolution magnetic resonance imaging (MRI) can enhance lesion diagnosis, prognosis, and delineation. However, gradient power and hardware limitations prohibit recording thin slices or sub-1 mm resolution. Furthermore, long scan time is not clinically acceptable. Conventional high-resolution images generated using statistical or analytical methods include the limitation of capturing complex, high-dimensional image data with intricate patterns and structures. This study aims to harness cutting-edge diffusion probabilistic deep learning techniques to create a framework for generating high-resolution MRI from low-resolution counterparts, improving the uncertainty of denoising diffusion probabilistic models (DDPM).Approach. DDPM includes two processes. The forward process employs a Markov chain to systematically introduce Gaussian noise to low-resolution MRI images. In the reverse process, a U-Net model is trained to denoise the forward process images and produce high-resolution images conditioned on the features of their low-resolution counterparts. The proposed framework was demonstrated using T2-weighted MRI images from institutional prostate patients and brain patients collected in the Brain Tumor Segmentation Challenge 2020 (BraTS2020).Main results. For the prostate dataset, the bicubic interpolation model (Bicubic), conditional generative-adversarial network (CGAN), and our proposed DDPM framework improved the noise quality measure from low-resolution images by 4.4%, 5.7%, and 12.8%, respectively. Our method enhanced the signal-to-noise ratios by 11.7%, surpassing Bicubic (9.8%) and CGAN (8.1%). In the BraTS2020 dataset, the proposed framework and Bicubic enhanced peak signal-to-noise ratio from resolution-degraded images by 9.1% and 5.8%. The multi-scale structural similarity indexes were 0.970 ± 0.019, 0.968 ± 0.022, and 0.967 ± 0.023 for the proposed method, CGAN, and Bicubic, respectively.Significance. This study explores a deep learning-based diffusion probabilistic framework for improving MR image resolution. Such a framework can be used to improve clinical workflow by obtaining high-resolution images without penalty of the long scan time. Future investigation will likely focus on prospectively testing the efficacy of this framework with different clinical indications.
Collapse
Affiliation(s)
- Chih-Wei Chang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Junbo Peng
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Mojtaba Safari
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Elahheh Salari
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Shaoyan Pan
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
- Department of Biomedical Informatics, Emory University, Atlanta, GA 30308, United States of America
| | - Justin Roper
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Richard L J Qiu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Yuan Gao
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Hui-Kuo Shu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Hui Mao
- Department of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, United States of America
- Department of Biomedical Informatics, Emory University, Atlanta, GA 30308, United States of America
| |
Collapse
|
19
|
García-Figueiras R, Baleato-González S, Luna A, Padhani AR, Vilanova JC, Carballo-Castro AM, Oleaga-Zufiria L, Vallejo-Casas JA, Marhuenda A, Gómez-Caamaño A. How Imaging Advances Are Defining the Future of Precision Radiation Therapy. Radiographics 2024; 44:e230152. [PMID: 38206833 DOI: 10.1148/rg.230152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
Radiation therapy is fundamental in the treatment of cancer. Imaging has always played a central role in radiation oncology. Integrating imaging technology into irradiation devices has increased the precision and accuracy of dose delivery and decreased the toxic effects of the treatment. Although CT has become the standard imaging modality in radiation therapy, the development of recently introduced next-generation imaging techniques has improved diagnostic and therapeutic decision making in radiation oncology. Functional and molecular imaging techniques, as well as other advanced imaging modalities such as SPECT, yield information about the anatomic and biologic characteristics of tumors for the radiation therapy workflow. In clinical practice, they can be useful for characterizing tumor phenotypes, delineating volumes, planning treatment, determining patients' prognoses, predicting toxic effects, assessing responses to therapy, and detecting tumor relapse. Next-generation imaging can enable personalization of radiation therapy based on a greater understanding of tumor biologic factors. It can be used to map tumor characteristics, such as metabolic pathways, vascularity, cellular proliferation, and hypoxia, that are known to define tumor phenotype. It can also be used to consider tumor heterogeneity by highlighting areas at risk for radiation resistance for focused biologic dose escalation, which can impact the radiation planning process and patient outcomes. The authors review the possible contributions of next-generation imaging to the treatment of patients undergoing radiation therapy. In addition, the possible roles of radio(geno)mics in radiation therapy, the limitations of these techniques, and hurdles in introducing them into clinical practice are discussed. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.
Collapse
Affiliation(s)
- Roberto García-Figueiras
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Sandra Baleato-González
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Antonio Luna
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Anwar R Padhani
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Joan C Vilanova
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Ana M Carballo-Castro
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Laura Oleaga-Zufiria
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Juan Antonio Vallejo-Casas
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Ana Marhuenda
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| | - Antonio Gómez-Caamaño
- From the Department of Radiology, Division of Oncologic Imaging (R.G.F., S.B.G.), and Department of Radiation Oncology (A.M.C.C., A.G.C.), Hospital Clínico Universitario de Santiago de Compostela, Choupana s/n, 15706 Santiago de Compostela, Spain; Department of Advanced Medical Imaging, Grupo Health Time, Sercosa (Servicio Radiologia Computerizada, Clínica Las Nieves, Jaén, Spain (A.L.); Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Northwood, Middlesex, England (A.R.P.); Department of Radiology, Clínica Girona and Hospital Santa Caterina, Girona, Spain (J.C.V.); Department of Radiology, Hospital Clínic Barcelona, Barcelona, Spain (L.O.Z.); Unidad de Gestión Clínica de Medicina Nuclear, Instituto Maimónides de Investigación Biomédica de Córdoba, Hospital Universitario Reina Sofía, Córdoba, Spain (J.A.V.C.); and Department of Radiology, Instituto Valenciano de Oncología, Valencia, Spain (A.M.)
| |
Collapse
|
20
|
Bird D, Speight R, Andersson S, Wingqvist J, Al-Qaisieh B. Deep learning MRI-only synthetic-CT generation for pelvis, brain and head and neck cancers. Radiother Oncol 2024; 191:110052. [PMID: 38096921 DOI: 10.1016/j.radonc.2023.110052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 12/07/2023] [Accepted: 12/10/2023] [Indexed: 12/19/2023]
Abstract
BACKGROUND AND PURPOSE MRI-only planning relies on dosimetrically accurate synthetic-CT (sCT) generation to allow dose calculation. Here we validated the dosimetric accuracy of sCTs generated using a deep learning algorithm for pelvic, brain and head and neck (H&N) cancer sites using variable MRI data from multiple scanners. METHODS sCT generation models were trained using a cycle-GAN algorithm, using paired MRI-CT patient data. Input MRI sequences were: T2 for pelvis, T1 with gadolinium (T1Gd) and T2 FLAIR for brain and T1 for H&N. Patient validation sCTs were generated for each site (49 - pelvis, 25 - brain and 30 - H&N). VMAT plans, following local clinical protocols, were calculated on planning CTs and recalculated on sCTs. HU and dosimetric differences were assessed, including DVH differences and gamma index (2 %/2mm). RESULTS Mean absolute error (MAE) HU differences were; 48.8 HU (pelvis), 118 HU (T2 FLAIR brain), 126 HU (T1Gd brain) and 124 HU (H&N). Mean primary PTV D95% dose differences for all sites were < 0.2 % (range: -0.9 to 1.0 %). Mean 2 %/2mm and 1 %/1mm gamma pass rates for all sites were > 99.6 % (min: 95.3 %) and > 97.3 % (min: 80.1 %) respectively. For all OARs for all sites, mean dose differences were < 0.4 %. CONCLUSION Generated sCTs had excellent dosimetric accuracy for all sites and sequences. The cycle-GAN model, available on the research version of a commercial treatment planning system, is a feasible method for sCT generation with high clinical utility due to its ability to use variable input data from multiple scanners and sequences.
Collapse
Affiliation(s)
- David Bird
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
| | - Richard Speight
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | | | | | - Bashar Al-Qaisieh
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| |
Collapse
|
21
|
Wang Z, Fang M, Zhang J, Tang L, Zhong L, Li H, Cao R, Zhao X, Liu S, Zhang R, Xie X, Mai H, Qiu S, Tian J, Dong D. Radiomics and Deep Learning in Nasopharyngeal Carcinoma: A Review. IEEE Rev Biomed Eng 2024; 17:118-135. [PMID: 37097799 DOI: 10.1109/rbme.2023.3269776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023]
Abstract
Nasopharyngeal carcinoma is a common head and neck malignancy with distinct clinical management compared to other types of cancer. Precision risk stratification and tailored therapeutic interventions are crucial to improving the survival outcomes. Artificial intelligence, including radiomics and deep learning, has exhibited considerable efficacy in various clinical tasks for nasopharyngeal carcinoma. These techniques leverage medical images and other clinical data to optimize clinical workflow and ultimately benefit patients. In this review, we provide an overview of the technical aspects and basic workflow of radiomics and deep learning in medical image analysis. We then conduct a detailed review of their applications to seven typical tasks in the clinical diagnosis and treatment of nasopharyngeal carcinoma, covering various aspects of image synthesis, lesion segmentation, diagnosis, and prognosis. The innovation and application effects of cutting-edge research are summarized. Recognizing the heterogeneity of the research field and the existing gap between research and clinical translation, potential avenues for improvement are discussed. We propose that these issues can be gradually addressed by establishing standardized large datasets, exploring the biological characteristics of features, and technological upgrades.
Collapse
|
22
|
Olsson LE, Af Wetterstedt S, Scherman J, Gunnlaugsson A, Persson E, Jamtheim Gustafsson C. Evaluation of a deep learning magnetic resonance imaging reconstruction method for synthetic computed tomography generation in prostate radiotherapy. Phys Imaging Radiat Oncol 2024; 29:100557. [PMID: 38414521 PMCID: PMC10897922 DOI: 10.1016/j.phro.2024.100557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 02/07/2024] [Accepted: 02/08/2024] [Indexed: 02/29/2024] Open
Abstract
Background and Purpose In magnetic resonance imaging (MRI) only radiotherapy computed tomography (CT) is excluded. The method relies entirely on synthetic CT images generated from MRI. This study evaluates the compatibility of a commercial synthetic CT (sCT) with an accelerated commercial deep learning reconstruction (DLR) in MRI-only prostate radiotherapy. Materials and Methods For a group of 24 patients (cohort 1) the effects of DLR were studied in isolation. MRI data were reconstructed conventionally and with DLR from identical k-space data, and sCTs were generated for both reconstructions. The sCT quality, Hounsfield Unit (HU) and dosimetric impact were investigated. In another group of 15 patients (cohort 2) effects on sCT generation using accelerated MRI acquisition (40 % time reduction) reconstructed with DLR were investigated. Results sCT images from both cohorts, generated from DLR MRI data, were of clinically expected image quality. The mean dose differences for targets and organs at risks in cohort 1 were <0.06 Gy, corresponding to a 0.1 % prescribed dose difference. Similar dose differences were observed in cohort 2. Gamma pass rates for cohort 1 were 100 % for criteria 3 %/3mm, 2 %/2mm and 1 %/1mm for all dose levels. Mean error and mean absolute error inside the body, between sCTs, averaged over all cohort 1 subjects, were -1.1 ± 0.6 [-2.4 0.2] and 2.9 ± 0.4 [2.3 3.9] HU, respectively. Conclusions DLR was suitable for sCT generation with clinically negligible differences in HU and calculated dose compared to the conventional MRI reconstruction method. For sCT generation DLR enables scan time reduction, without compromised sCT quality.
Collapse
Affiliation(s)
- Lars E Olsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Carl Bertil Laurells gata 9, Malmö 205 02, Sweden
| | - Sacha Af Wetterstedt
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
| | - Jonas Scherman
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
| | - Adalsteinn Gunnlaugsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
| | - Emilia Persson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Carl Bertil Laurells gata 9, Malmö 205 02, Sweden
| | - Christian Jamtheim Gustafsson
- Radiation Physics, Department of Hematology, Oncology, and Radiation Physics, Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Carl Bertil Laurells gata 9, Malmö 205 02, Sweden
| |
Collapse
|
23
|
Guckenberger M, Andratschke N, Chung C, Fuller D, Tanadini-Lang S, Jaffray DA. The Future of MR-Guided Radiation Therapy. Semin Radiat Oncol 2024; 34:135-144. [PMID: 38105088 DOI: 10.1016/j.semradonc.2023.10.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Magnetic resonance image guided radiation therapy (MRIgRT) is a relatively new technology that has already shown outcomes benefits but that has not yet reached its clinical potential. The improved soft-tissue contrast provided with MR, coupled with the immediacy of image acquisition with respect to the treatment, enables expansion of on-table adaptive protocols, currently at a cost of increased treatment complexity, use of human resources, and longer treatment slot times, which translate to decreased throughput. Many approaches are being investigated to meet these challenges, including the development of artificial intelligence (AI) algorithms to accelerate and automate much of the workflow and improved technology that parallelizes workflow tasks, as well as improvements in image acquisition speed and quality. This article summarizes limitations of current available integrated MRIgRT systems and gives an outlook about scientific developments to further expand the use of MRIgRT.
Collapse
Affiliation(s)
- Matthias Guckenberger
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland..
| | - Nicolaus Andratschke
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Caroline Chung
- Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Dave Fuller
- Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Stephanie Tanadini-Lang
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - David A Jaffray
- Division of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
24
|
Putz F, Bock M, Schmitt D, Bert C, Blanck O, Ruge MI, Hattingen E, Karger CP, Fietkau R, Grigo J, Schmidt MA, Bäuerle T, Wittig A. Quality requirements for MRI simulation in cranial stereotactic radiotherapy: a guideline from the German Taskforce "Imaging in Stereotactic Radiotherapy". Strahlenther Onkol 2024; 200:1-18. [PMID: 38163834 PMCID: PMC10784363 DOI: 10.1007/s00066-023-02183-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 11/06/2023] [Indexed: 01/03/2024]
Abstract
Accurate Magnetic Resonance Imaging (MRI) simulation is fundamental for high-precision stereotactic radiosurgery and fractionated stereotactic radiotherapy, collectively referred to as stereotactic radiotherapy (SRT), to deliver doses of high biological effectiveness to well-defined cranial targets. Multiple MRI hardware related factors as well as scanner configuration and sequence protocol parameters can affect the imaging accuracy and need to be optimized for the special purpose of radiotherapy treatment planning. MRI simulation for SRT is possible for different organizational environments including patient referral for imaging as well as dedicated MRI simulation in the radiotherapy department but require radiotherapy-optimized MRI protocols and defined quality standards to ensure geometrically accurate images that form an impeccable foundation for treatment planning. For this guideline, an interdisciplinary panel including experts from the working group for radiosurgery and stereotactic radiotherapy of the German Society for Radiation Oncology (DEGRO), the working group for physics and technology in stereotactic radiotherapy of the German Society for Medical Physics (DGMP), the German Society of Neurosurgery (DGNC), the German Society of Neuroradiology (DGNR) and the German Chapter of the International Society for Magnetic Resonance in Medicine (DS-ISMRM) have defined minimum MRI quality requirements as well as advanced MRI simulation options for cranial SRT.
Collapse
Affiliation(s)
- Florian Putz
- Strahlenklinik, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
| | - Michael Bock
- Klinik für Radiologie-Medizinphysik, Universitätsklinikum Freiburg, Freiburg, Germany
| | - Daniela Schmitt
- Klinik für Strahlentherapie und Radioonkologie, Universitätsmedizin Göttingen, Göttingen, Germany
| | - Christoph Bert
- Strahlenklinik, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Oliver Blanck
- Klinik für Strahlentherapie, Universitätsklinikum Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Maximilian I Ruge
- Klinik für Stereotaxie und funktionelle Neurochirurgie, Zentrum für Neurochirurgie, Universitätsklinikum Köln, Cologne, Germany
| | - Elke Hattingen
- Institut für Neuroradiologie, Universitätsklinikum Frankfurt, Frankfurt am Main, Germany
| | - Christian P Karger
- Abteilung Medizinische Physik in der Strahlentherapie, Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Germany
- Nationales Zentrum für Strahlenforschung in der Onkologie (NCRO), Heidelberger Institut für Radioonkologie (HIRO), Heidelberg, Germany
| | - Rainer Fietkau
- Strahlenklinik, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Johanna Grigo
- Strahlenklinik, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Manuel A Schmidt
- Neuroradiologisches Institut, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Tobias Bäuerle
- Radiologisches Institut, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Andrea Wittig
- Klinik und Poliklinik für Strahlentherapie und Radioonkologie, Universitätsklinikum Würzburg, Würzburg, Germany
| |
Collapse
|
25
|
Nenoff L, Amstutz F, Murr M, Archibald-Heeren B, Fusella M, Hussein M, Lechner W, Zhang Y, Sharp G, Vasquez Osorio E. Review and recommendations on deformable image registration uncertainties for radiotherapy applications. Phys Med Biol 2023; 68:24TR01. [PMID: 37972540 PMCID: PMC10725576 DOI: 10.1088/1361-6560/ad0d8a] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 10/30/2023] [Accepted: 11/15/2023] [Indexed: 11/19/2023]
Abstract
Deformable image registration (DIR) is a versatile tool used in many applications in radiotherapy (RT). DIR algorithms have been implemented in many commercial treatment planning systems providing accessible and easy-to-use solutions. However, the geometric uncertainty of DIR can be large and difficult to quantify, resulting in barriers to clinical practice. Currently, there is no agreement in the RT community on how to quantify these uncertainties and determine thresholds that distinguish a good DIR result from a poor one. This review summarises the current literature on sources of DIR uncertainties and their impact on RT applications. Recommendations are provided on how to handle these uncertainties for patient-specific use, commissioning, and research. Recommendations are also provided for developers and vendors to help users to understand DIR uncertainties and make the application of DIR in RT safer and more reliable.
Collapse
Affiliation(s)
- Lena Nenoff
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, United States of America
- Harvard Medical School, Boston, MA, United States of America
- OncoRay—National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden—Rossendorf, Dresden Germany
- Helmholtz-Zentrum Dresden—Rossendorf, Institute of Radiooncology—OncoRay, Dresden, Germany
| | - Florian Amstutz
- Department of Physics, ETH Zurich, Switzerland
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Switzerland
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Martina Murr
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Germany
| | | | - Marco Fusella
- Department of Radiation Oncology, Abano Terme Hospital, Italy
| | - Mohammad Hussein
- Metrology for Medical Physics, National Physical Laboratory, Teddington, United Kingdom
| | - Wolfgang Lechner
- Department of Radiation Oncology, Medical University of Vienna, Austria
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, Switzerland
| | - Greg Sharp
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, United States of America
- Harvard Medical School, Boston, MA, United States of America
| | - Eliana Vasquez Osorio
- Division of Cancer Sciences, The University of Manchester, Manchester, United Kingdom
| |
Collapse
|
26
|
Honkamaa J, Khan U, Koivukoski S, Valkonen M, Latonen L, Ruusuvuori P, Marttinen P. Deformation equivariant cross-modality image synthesis with paired non-aligned training data. Med Image Anal 2023; 90:102940. [PMID: 37666115 DOI: 10.1016/j.media.2023.102940] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 08/14/2023] [Accepted: 08/18/2023] [Indexed: 09/06/2023]
Abstract
Cross-modality image synthesis is an active research topic with multiple medical clinically relevant applications. Recently, methods allowing training with paired but misaligned data have started to emerge. However, no robust and well-performing methods applicable to a wide range of real world data sets exist. In this work, we propose a generic solution to the problem of cross-modality image synthesis with paired but non-aligned data by introducing new deformation equivariance encouraging loss functions. The method consists of joint training of an image synthesis network together with separate registration networks and allows adversarial training conditioned on the input even with misaligned data. The work lowers the bar for new clinical applications by allowing effortless training of cross-modality image synthesis networks for more difficult data sets.
Collapse
Affiliation(s)
- Joel Honkamaa
- Department of Computer Science, Aalto University, Finland.
| | - Umair Khan
- Institute of Biomedicine, University of Turku, Finland
| | - Sonja Koivukoski
- Institute of Biomedicine, University of Eastern Finland, Kuopio, Finland
| | - Mira Valkonen
- Faculty of Medicine and Health Technology, Tampere University, Finland
| | - Leena Latonen
- Institute of Biomedicine, University of Eastern Finland, Kuopio, Finland
| | - Pekka Ruusuvuori
- Institute of Biomedicine, University of Turku, Finland; Faculty of Medicine and Health Technology, Tampere University, Finland
| | | |
Collapse
|
27
|
Yuan S, Chen X, Liu Y, Zhu J, Men K, Dai J. Comprehensive evaluation of similarity between synthetic and real CT images for nasopharyngeal carcinoma. Radiat Oncol 2023; 18:182. [PMID: 37936196 PMCID: PMC10629140 DOI: 10.1186/s13014-023-02349-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 09/11/2023] [Indexed: 11/09/2023] Open
Abstract
BACKGROUND Although magnetic resonance imaging (MRI)-to-computed tomography (CT) synthesis studies based on deep learning have significantly progressed, the similarity between synthetic CT (sCT) and real CT (rCT) has only been evaluated in image quality metrics (IQMs). To evaluate the similarity between synthetic CT (sCT) and real CT (rCT) comprehensively, we comprehensively evaluated IQMs and radiomic features for the first time. METHODS This study enrolled 127 patients with nasopharyngeal carcinoma who underwent CT and MRI scans. Supervised-learning (Unet) and unsupervised-learning (CycleGAN) methods were applied to build MRI-to-CT synthesis models. The regions of interest (ROIs) included nasopharynx gross tumor volume (GTVnx), brainstem, parotid glands, and temporal lobes. The peak signal-to-noise ratio (PSNR), mean absolute error (MAE), root mean square error (RMSE), and structural similarity (SSIM) were used to evaluate image quality. Additionally, 837 radiomic features were extracted for each ROI, and the correlation was evaluated using the concordance correlation coefficient (CCC). RESULTS The MAE, RMSE, SSIM, and PSNR of the body were 91.99, 187.12, 0.97, and 51.15 for Unet and 108.30, 211.63, 0.96, and 49.84 for CycleGAN. For the metrics, Unet was superior to CycleGAN (P < 0.05). For the radiomic features, the percentage of four levels (i.e., excellent, good, moderate, and poor, respectively) were as follows: GTVnx, 8.5%, 14.6%, 26.5%, and 50.4% for Unet and 12.3%, 25%, 38.4%, and 24.4% for CycleGAN; other ROIs, 5.44% ± 3.27%, 5.56% ± 2.92%, 21.38% ± 6.91%, and 67.58% ± 8.96% for Unet and 5.16% ± 1.69%, 3.5% ± 1.52%, 12.68% ± 7.51%, and 78.62% ± 8.57% for CycleGAN. CONCLUSIONS Unet-sCT was superior to CycleGAN-sCT for the IQMs. However, neither exhibited absolute superiority in radiomic features, and both were far less similar to rCT. Therefore, further work is required to improve the radiomic similarity for MRI-to-CT synthesis. TRIAL REGISTRATION This study was a retrospective study, so it was free from registration.
Collapse
Affiliation(s)
- Siqi Yuan
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Xinyuan Chen
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Yuxiang Liu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Ji Zhu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Kuo Men
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| | - Jianrong Dai
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| |
Collapse
|
28
|
Salzillo TC, Dresner MA, Way A, Wahid KA, McDonald BA, Mulder S, Naser MA, He R, Ding Y, Yoder A, Ahmed S, Corrigan KL, Manzar GS, Andring L, Pinnix C, Stafford RJ, Mohamed ASR, Christodouleas J, Wang J, Fuller CD. Development and implementation of optimized endogenous contrast sequences for delineation in adaptive radiotherapy on a 1.5T MR-linear-accelerator: a prospective R-IDEAL stage 0-2a quantitative/qualitative evaluation of in vivo site-specific quality-assurance using a 3D T2 fat-suppressed platform for head and neck cancer. J Med Imaging (Bellingham) 2023; 10:065501. [PMID: 37937259 PMCID: PMC10627232 DOI: 10.1117/1.jmi.10.6.065501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 10/06/2023] [Accepted: 10/16/2023] [Indexed: 11/09/2023] Open
Abstract
Purpose To improve segmentation accuracy in head and neck cancer (HNC) radiotherapy treatment planning for the 1.5T hybrid magnetic resonance imaging/linear accelerator (MR-Linac), three-dimensional (3D), T2-weighted, fat-suppressed magnetic resonance imaging sequences were developed and optimized. Approach After initial testing, spectral attenuated inversion recovery (SPAIR) was chosen as the fat suppression technique. Five candidate SPAIR sequences and a nonsuppressed, T2-weighted sequence were acquired for five HNC patients using a 1.5T MR-Linac. MR physicists identified persistent artifacts in two of the SPAIR sequences, so the remaining three SPAIR sequences were further analyzed. The gross primary tumor volume, metastatic lymph nodes, parotid glands, and pterygoid muscles were delineated using five segmentors. A robust image quality analysis platform was developed to objectively score the SPAIR sequences on the basis of qualitative and quantitative metrics. Results Sequences were analyzed for the signal-to-noise ratio and the contrast-to-noise ratio and compared with fat and muscle, conspicuity, pairwise distance metrics, and segmentor assessments. In this analysis, the nonsuppressed sequence was inferior to each of the SPAIR sequences for the primary tumor, lymph nodes, and parotid glands, but it was superior for the pterygoid muscles. The SPAIR sequence that received the highest combined score among the analysis categories was recommended to Unity MR-Linac users for HNC radiotherapy treatment planning. Conclusions Our study led to two developments: an optimized, 3D, T2-weighted, fat-suppressed sequence that can be disseminated to Unity MR-Linac users and a robust image quality analysis pathway that can be used to objectively score SPAIR sequences and can be customized and generalized to any image quality optimization protocol. Improved segmentation accuracy with the proposed SPAIR sequence will potentially lead to improved treatment outcomes and reduced toxicity for patients by maximizing the target coverage and minimizing the radiation exposure of organs at risk.
Collapse
Affiliation(s)
- Joint Head and Neck Radiotherapy-MRI Development Cooperative
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
- Philips Healthcare, Cleveland, Ohio, United States
- MD Anderson Cancer Center, Radiation Physics, Houston, Texas, United States
- MD Anderson Cancer Center, Imaging Physics, Houston, Texas, United States
- Elekta AB, Stockholm, Sweden
| | - Travis C. Salzillo
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | | | - Ashley Way
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Kareem A. Wahid
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Brigid A. McDonald
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Sam Mulder
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Mohamed A. Naser
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Renjie He
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Yao Ding
- MD Anderson Cancer Center, Radiation Physics, Houston, Texas, United States
| | - Alison Yoder
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Sara Ahmed
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Kelsey L. Corrigan
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Gohar S. Manzar
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Lauren Andring
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - Chelsea Pinnix
- MD Anderson Cancer Center, Radiation Oncology, Houston, Texas, United States
| | - R. Jason Stafford
- MD Anderson Cancer Center, Imaging Physics, Houston, Texas, United States
| | | | | | - Jihong Wang
- MD Anderson Cancer Center, Radiation Physics, Houston, Texas, United States
| | | |
Collapse
|
29
|
Autret D, Guillerminet C, Roussel A, Cossec-Kerloc'h E, Dufreneix S. Comparison of four synthetic CT generators for brain and prostate MR-only workflow in radiotherapy. Radiat Oncol 2023; 18:146. [PMID: 37670397 PMCID: PMC10478301 DOI: 10.1186/s13014-023-02336-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 08/23/2023] [Indexed: 09/07/2023] Open
Abstract
BACKGROUND The interest in MR-only workflows is growing with the introduction of artificial intelligence in the synthetic CT generators converting MR images into CT images. The aim of this study was to evaluate several commercially available sCT generators for two anatomical localizations. METHODS Four sCT generators were evaluated: one based on the bulk density method and three based on deep learning methods. The comparison was performed on large patient cohorts (brain: 42 patients and pelvis: 52 patients). It included geometric accuracy with the evaluation of Hounsfield Units (HU) mean error (ME) for several structures like the body, bones and soft tissues. Dose evaluation included metrics like the Dmean ME for bone structures (skull or femoral heads), PTV and soft tissues (brain or bladder or rectum). A 1%/1 mm gamma analysis was also performed. RESULTS HU ME in the body were similar to those reported in the literature. Dmean ME were smaller than 2% for all structures. Mean gamma pass rate down to 78% were observed for the bulk density method in the brain. Performances of the bulk density generator were generally worse than the artificial intelligence generators for the brain but similar for the pelvis. None of the generators performed best in all the metrics studied. CONCLUSIONS All four generators can be used in clinical practice to implement a MR-only workflow but the bulk density method clearly performed worst in the brain.
Collapse
Affiliation(s)
| | | | | | | | - Stéphane Dufreneix
- Institut de Cancérologie de l'Ouest, Angers, France.
- CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), Palaiseau, France.
| |
Collapse
|
30
|
Ranta I, Wright P, Suilamo S, Kemppainen R, Schubert G, Kapanen M, Keyriläinen J. Clinical feasibility of a commercially available MRI-only method for radiotherapy treatment planning of the brain. J Appl Clin Med Phys 2023; 24:e14044. [PMID: 37345212 PMCID: PMC10476982 DOI: 10.1002/acm2.14044] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 01/19/2023] [Accepted: 04/25/2023] [Indexed: 06/23/2023] Open
Abstract
BACKGROUND Advancements in deep-learning based synthetic computed tomography (sCT) image conversion methods have enabled the development of magnetic resonance imaging (MRI)-only based radiotherapy treatment planning (RTP) of the brain. PURPOSE This study evaluates the clinical feasibility of a commercial, deep-learning based MRI-only RTP method with respect to dose calculation and patient positioning verification performance in RTP of the brain. METHODS Clinical validation of dose calculation accuracy was performed by a retrospective evaluation for 25 glioma and 25 brain metastasis patients. Dosimetric and image quality of the studied MRI-only RTP method was evaluated by a direct comparison of the sCT-based and computed tomography (CT)-based external beam radiation therapy (EBRT) images and treatment plans. Patient positioning verification accuracy of sCT images was evaluated retrospectively for 10 glioma and 10 brain metastasis patients based on clinical cone-beam computed tomography (CBCT) imaging. RESULTS An average mean dose difference of Dmean = 0.1% for planning target volume (PTV) and 0.6% for normal tissue (NT) structures were obtained for glioma patients. Respective results for brain metastasis patients were Dmean = 0.5% for PTVs and Dmean =1.0% for NTs. Global three-dimensional (3D) gamma pass rates using 2%/2 mm dose difference and distance-to-agreement (DTA) criterion were 98.0% for the glioma subgroup, and 95.2% for the brain metastasis subgroup using 1%/1 mm criterion. Mean distance differences of <1.0 mm were observed in all Cartesian directions between CT-based and sCT-based CBCT patient positioning in both subgroups. CONCLUSIONS In terms of dose calculation and patient positioning accuracy, the studied MRI-only method demonstrated its clinical feasibility for RTP of the brain. The results encourage the use of the studied method as part of a routine clinical workflow.
Collapse
Affiliation(s)
- Iiro Ranta
- Department of Physics and AstronomyUniversity of TurkuTurkuFinland
- Department of Medical PhysicsTurku University HospitalTurkuFinland
- Department of Oncology and RadiotherapyTurku University HospitalTurkuFinland
| | - Pauliina Wright
- Department of Medical PhysicsTurku University HospitalTurkuFinland
- Department of Oncology and RadiotherapyTurku University HospitalTurkuFinland
| | - Sami Suilamo
- Department of Medical PhysicsTurku University HospitalTurkuFinland
- Department of Oncology and RadiotherapyTurku University HospitalTurkuFinland
| | - Reko Kemppainen
- HUS Diagnostic CenterUniversity of Helsinki and Helsinki University HospitalHelsinkiFinland
| | | | - Mika Kapanen
- Department of Medical PhysicsMedical Imaging CenterTampere University HospitalTampereFinland
- Department of OncologyUnit of RadiotherapyTampere University HospitalTampereFinland
| | - Jani Keyriläinen
- Department of Physics and AstronomyUniversity of TurkuTurkuFinland
- Department of Medical PhysicsTurku University HospitalTurkuFinland
- Department of Oncology and RadiotherapyTurku University HospitalTurkuFinland
| |
Collapse
|
31
|
Shusharina N, Nguyen C. Consistency of muscle fibers directionality in human thigh derived from diffusion-weighted MRI. Phys Med Biol 2023; 68:175045. [PMID: 37586375 PMCID: PMC10472329 DOI: 10.1088/1361-6560/acf10c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 08/16/2023] [Indexed: 08/18/2023]
Abstract
Objective.Diffusion-weighted MR imaging (DW-MRI) is known to quantify muscle fiber directionality and thus may be useful for radiotherapy target definition in sarcomas. Here, we investigate the variability of tissue anisotropy derived from diffusion tensor (DT) in the human thigh to establish the baseline parameters and protocols for DW-MRI acquisition for future studies in sarcoma patients.Approach.We recruited ten healthy volunteers to acquire diffusion-weighted MR images of the left and right thigh. DW-MRI data were used to reconstruct DT eigenvectors within each individual thigh muscle. Deviations of the principal eigenvector from its mean were calculated for different experimental conditions.Main results.Within the majority of muscles in most subjects, the mode of the histogram of the angular deviation of the principal eigenvector of the water DT from its muscle-averaged value did not exceed 20°. On average for all subjects, the mode ranged from 15° to 24°. Deviations much larger than 20° were observed in muscles far from the RF coil, including cases with significant amounts of subcutaneous fat and muscle deformation under its own weight.Significance.Our study is a robust characterization of angular deviations of muscle fiber directionality in the thigh as determined by DW-MRI. We show that an appropriate choice of experimental conditions reduces the variability of the observed directionality. Precise determination of tissue directionality will enable reproducible models of microscopic tumor spread, with future application in defining the clinical target volume for soft tissue sarcoma.
Collapse
Affiliation(s)
- Nadya Shusharina
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA 02114, United States of America
- Harvard Medical School, Boston, MA 02115, United States of America
| | - Christopher Nguyen
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, OH, United States of America
| |
Collapse
|
32
|
Young T, Dowling J, Rai R, Liney G, Greer P, Thwaites D, Holloway L. Clinical validation of MR imaging time reduction for substitute/synthetic CT generation for prostate MRI-only treatment planning. Phys Eng Sci Med 2023; 46:1015-1021. [PMID: 37219797 PMCID: PMC10480277 DOI: 10.1007/s13246-023-01268-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 04/26/2023] [Indexed: 05/24/2023]
Abstract
Radiotherapy treatment planning based only on magnetic resonance imaging (MRI) has become clinically achievable. Though computed tomography (CT) is the gold standard for radiotherapy imaging, directly providing the electron density values needed for planning calculations, MRI has superior soft tissue visualisation to guide treatment planning decisions and optimisation. MRI-only planning removes the need for the CT scan, but requires generation of a substitute/synthetic/pseudo CT (sCT) for electron density information. Shortening the MRI imaging time would improve patient comfort and reduce the likelihood of motion artefacts. A volunteer study was previously carried out to investigate and optimise faster MRI sequences for a hybrid atlas-voxel conversion to sCT for prostate treatment planning. The aim of this follow-on study was to clinically validate the performance of the new optimised sequence for sCT generation in a treated MRI-only prostate patient cohort. 10 patients undergoing MRI-only treatment were scanned on a Siemens Skyra 3T MRI as part of the MRI-only sub-study of the NINJA clinical trial (ACTRN12618001806257). Two sequences were used, the standard 3D T2-weighted SPACE sequence used for sCT conversion which has been previously validated against CT, and a modified fast SPACE sequence, selected based on the volunteer study. Both were used to generate sCT scans. These were then compared to evaluate the fast sequence conversion for anatomical and dosimetric accuracy against the clinically approved treatment plans. The average Mean Absolute Error (MAE) for the body was 14.98 ± 2.35 HU, and for bone was 40.77 ± 5.51 HU. The external volume contour comparison produced a Dice Similarity Coefficient (DSC) of at least 0.976, and an average of 0.985 ± 0.004, and the bony anatomy contour comparison a DSC of at least 0.907, and an average of 0.950 ± 0.018. The fast SPACE sCT agreed with the gold standard sCT within an isocentre dose of -0.28% ± 0.16% and an average gamma pass rate of 99.66% ± 0.41% for a 1%/1 mm gamma tolerance. In this clinical validation study, the fast sequence, which reduced the required imaging time by approximately a factor of 4, produced an sCT with similar clinical dosimetric results compared to the standard sCT, demonstrating its potential for clinical use for treatment planning.
Collapse
Affiliation(s)
- Tony Young
- Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, Sydney, Australia
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia
| | - Jason Dowling
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia
- CSIRO Health and Biosecurity, The Australian e-Health & Research Centre, Brisbane, QLD Australia
- South Western Sydney Clinical School, University of New South Wales, Sydney, NSW Australia
- School of Mathematical and Physical Sciences, University of Newcastle, Callaghan, NSW Australia
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW Australia
| | - Robba Rai
- Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, Sydney, Australia
- South Western Sydney Clinical School, University of New South Wales, Sydney, NSW Australia
| | - Gary Liney
- Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, Sydney, Australia
- South Western Sydney Clinical School, University of New South Wales, Sydney, NSW Australia
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW Australia
| | - Peter Greer
- School of Mathematical and Physical Sciences, University of Newcastle, Callaghan, NSW Australia
- Calvary Mater Newcastle Hospital, Newcastle, NSW Australia
| | - David Thwaites
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia
| | - Lois Holloway
- Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, Sydney, Australia
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia
- South Western Sydney Clinical School, University of New South Wales, Sydney, NSW Australia
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW Australia
| |
Collapse
|
33
|
Zhao Y, Chen X, McDonald B, Yu C, Mohamed ASR, Fuller CD, Court LE, Pan T, Wang H, Wang X, Phan J, Yang J. A transformer-based hierarchical registration framework for multimodality deformable image registration. Comput Med Imaging Graph 2023; 108:102286. [PMID: 37625307 PMCID: PMC10873569 DOI: 10.1016/j.compmedimag.2023.102286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 07/04/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023]
Abstract
Deformable image registration (DIR) between daily and reference images is fundamentally important for adaptive radiotherapy. In the last decade, deep learning-based image registration methods have been developed with faster computation time and improved robustness compared to traditional methods. However, the registration performance is often degraded in extra-cranial sites with large volume containing multiple anatomic regions, such as Computed Tomography (CT)/Magnetic Resonance (MR) images used in head and neck (HN) radiotherapy. In this study, we developed a hierarchical deformable image registration (DIR) framework, Patch-based Registration Network (Patch-RegNet), to improve the accuracy and speed of CT-MR and MR-MR registration for head-and-neck MR-Linac treatments. Patch-RegNet includes three steps: a whole volume global registration, a patch-based local registration, and a patch-based deformable registration. Following a whole-volume rigid registration, the input images were divided into overlapping patches. Then a patch-based rigid registration was applied to achieve accurate local alignment for subsequent DIR. We developed a ViT-Morph model, a combination of a convolutional neural network (CNN) and the Vision Transformer (ViT), for the patch-based DIR. A modality independent neighborhood descriptor was adopted in our model as the similarity metric to account for both inter-modality and intra-modality registration. The CT-MR and MR-MR DIR models were trained with 242 CT-MR and 213 MR-MR image pairs from 36 patients, respectively, and both tested with 24 image pairs (CT-MR and MR-MR) from 6 other patients. The registration performance was evaluated with 7 manually contoured organs (brainstem, spinal cord, mandible, left/right parotids, left/right submandibular glands) by comparing with the traditional registration methods in Monaco treatment planning system and the popular deep learning-based DIR framework, Voxelmorph. Evaluation results show that our method outperformed VoxelMorph by 6 % for CT-MR registration, and 4 % for MR-MR registration based on DSC measurements. Our hierarchical registration framework has been demonstrated achieving significantly improved DIR accuracy of both CT-MR and MR-MR registration for head-and-neck MR-guided adaptive radiotherapy.
Collapse
Affiliation(s)
- Yao Zhao
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Xinru Chen
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Brigid McDonald
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Cenji Yu
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Abdalah S R Mohamed
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Clifton D Fuller
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Laurence E Court
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Tinsu Pan
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - He Wang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Xin Wang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA
| | - Jack Phan
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Jinzhong Yang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, TX, USA.
| |
Collapse
|
34
|
Nijskens L, van den Berg CAT, Verhoeff JJC, Maspero M. Exploring contrast generalisation in deep learning-based brain MRI-to-CT synthesis. Phys Med 2023; 112:102642. [PMID: 37473612 DOI: 10.1016/j.ejmp.2023.102642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/24/2023] [Accepted: 07/05/2023] [Indexed: 07/22/2023] Open
Abstract
BACKGROUND Synthetic computed tomography (sCT) has been proposed and increasingly clinically adopted to enable magnetic resonance imaging (MRI)-based radiotherapy. Deep learning (DL) has recently demonstrated the ability to generate accurate sCT from fixed MRI acquisitions. However, MRI protocols may change over time or differ between centres resulting in low-quality sCT due to poor model generalisation. PURPOSE investigating domain randomisation (DR) to increase the generalisation of a DL model for brain sCT generation. METHODS CT and corresponding T1-weighted MRI with/without contrast, T2-weighted, and FLAIR MRI from 95 patients undergoing RT were collected, considering FLAIR the unseen sequence where to investigate generalisation. A "Baseline" generative adversarial network was trained with/without the FLAIR sequence to test how a model performs without DR. Image similarity and accuracy of sCT-based dose plans were assessed against CT to select the best-performing DR approach against the Baseline. RESULTS The Baseline model had the poorest performance on FLAIR, with mean absolute error (MAE) = 106 ± 20.7 HU (mean ±σ). Performance on FLAIR significantly improved for the DR model with MAE = 99.0 ± 14.9 HU, but still inferior to the performance of the Baseline+FLAIR model (MAE = 72.6 ± 10.1 HU). Similarly, an improvement in γ-pass rate was obtained for DR vs Baseline. CONCLUSION DR improved image similarity and dose accuracy on the unseen sequence compared to training only on acquired MRI. DR makes the model more robust, reducing the need for re-training when applying a model on sequences unseen and unavailable for retraining.
Collapse
Affiliation(s)
- Lotte Nijskens
- Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Science, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, 3584CX, The Netherlands; Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, 3584CX, The Netherlands
| | - Cornelis A T van den Berg
- Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Science, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, 3584CX, The Netherlands; Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, 3584CX, The Netherlands
| | - Joost J C Verhoeff
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, 3584CX, The Netherlands
| | - Matteo Maspero
- Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Science, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, 3584CX, The Netherlands; Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht, 3584CX, The Netherlands.
| |
Collapse
|
35
|
He M, Cao Y, Chi C, Yang X, Ramin R, Wang S, Yang G, Mukhtorov O, Zhang L, Kazantsev A, Enikeev M, Hu K. Research progress on deep learning in magnetic resonance imaging-based diagnosis and treatment of prostate cancer: a review on the current status and perspectives. Front Oncol 2023; 13:1189370. [PMID: 37546423 PMCID: PMC10400334 DOI: 10.3389/fonc.2023.1189370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 05/30/2023] [Indexed: 08/08/2023] Open
Abstract
Multiparametric magnetic resonance imaging (mpMRI) has emerged as a first-line screening and diagnostic tool for prostate cancer, aiding in treatment selection and noninvasive radiotherapy guidance. However, the manual interpretation of MRI data is challenging and time-consuming, which may impact sensitivity and specificity. With recent technological advances, artificial intelligence (AI) in the form of computer-aided diagnosis (CAD) based on MRI data has been applied to prostate cancer diagnosis and treatment. Among AI techniques, deep learning involving convolutional neural networks contributes to detection, segmentation, scoring, grading, and prognostic evaluation of prostate cancer. CAD systems have automatic operation, rapid processing, and accuracy, incorporating multiple sequences of multiparametric MRI data of the prostate gland into the deep learning model. Thus, they have become a research direction of great interest, especially in smart healthcare. This review highlights the current progress of deep learning technology in MRI-based diagnosis and treatment of prostate cancer. The key elements of deep learning-based MRI image processing in CAD systems and radiotherapy of prostate cancer are briefly described, making it understandable not only for radiologists but also for general physicians without specialized imaging interpretation training. Deep learning technology enables lesion identification, detection, and segmentation, grading and scoring of prostate cancer, and prediction of postoperative recurrence and prognostic outcomes. The diagnostic accuracy of deep learning can be improved by optimizing models and algorithms, expanding medical database resources, and combining multi-omics data and comprehensive analysis of various morphological data. Deep learning has the potential to become the key diagnostic method in prostate cancer diagnosis and treatment in the future.
Collapse
Affiliation(s)
- Mingze He
- Institute for Urology and Reproductive Health, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Yu Cao
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Changliang Chi
- Department of Urology, The First Hospital of Jilin University (Lequn Branch), Changchun, Jilin, China
| | - Xinyi Yang
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Rzayev Ramin
- Department of Radiology, The Second University Clinic, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Shuowen Wang
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Guodong Yang
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Otabek Mukhtorov
- Regional State Budgetary Health Care Institution, Kostroma Regional Clinical Hospital named after Korolev E.I. Avenue Mira, Kostroma, Russia
| | - Liqun Zhang
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian, Liaoning, China
| | - Anton Kazantsev
- Regional State Budgetary Health Care Institution, Kostroma Regional Clinical Hospital named after Korolev E.I. Avenue Mira, Kostroma, Russia
| | - Mikhail Enikeev
- Institute for Urology and Reproductive Health, I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - Kebang Hu
- Department of Urology, The First Hospital of Jilin University (Lequn Branch), Changchun, Jilin, China
| |
Collapse
|
36
|
He Q, Dong M, Summerfield N, Glide-Hurst C. MAGNET: A MODALITY-AGNOSTIC NETWORK FOR 3D MEDICAL IMAGE SEGMENTATION. PROCEEDINGS. IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING 2023; 2023:10.1109/isbi53787.2023.10230587. [PMID: 38169907 PMCID: PMC10760993 DOI: 10.1109/isbi53787.2023.10230587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
In this paper, we proposed MAGNET, a novel modality-agnostic network for 3D medical image segmentation. Different from existing learning methods, MAGNET is specifically designed to handle real medical situations where multiple modalities/sequences are available during model training, but fewer ones are available or used at time of clinical practice. Our results on multiple datasets show that MAGNET trained on multi-modality data has the unique ability to perform predictions using any subset of training imaging modalities. It outperforms individually trained uni-modality models while can further boost performance when more modalities are available at testing.
Collapse
Affiliation(s)
- Qisheng He
- Wayne State University Department of Computer Science 5057 Woodward Ave, Detroit, MI 48202
| | - Ming Dong
- Wayne State University Department of Computer Science 5057 Woodward Ave, Detroit, MI 48202
| | - Nicholas Summerfield
- University of Wisconsin-Madison Department of Human Oncology Department of Medical Physics 600 Highland Ave, Madison, WI 53792
| | - Carri Glide-Hurst
- University of Wisconsin-Madison Department of Human Oncology Department of Medical Physics 600 Highland Ave, Madison, WI 53792
| |
Collapse
|
37
|
Scherman J, af Wetterstedt S, Persson E, Olsson LE, Jamtheim Gustafsson C. Geometric impact and dose estimation of on-patient placement of a lightweight receiver coil in a clinical magnetic resonance imaging-only radiotherapy workflow for prostate cancer. Phys Imaging Radiat Oncol 2023; 26:100433. [PMID: 37063614 PMCID: PMC10091035 DOI: 10.1016/j.phro.2023.100433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 03/14/2023] [Accepted: 03/17/2023] [Indexed: 04/18/2023] Open
Abstract
Background and Purpose For pelvic magnetic resonance imaging (MRI)-only radiotherapy the use of receiver coil bridges (CB) is recommended to avoid deformation of the patient. Development in coil technology has enabled lightweight, flexible coils. In this work we evaluate the effects of a lightweight coil in a pelvic MRI-only radiotherapy workflow. Materials and Methods Twenty-one patients, referred to prostate MRI-only radiotherapy, were included. Images were acquired with and without CB. Anatomical deformation from the on-patient coil placement was measured in the anterior-posterior (AP) and left-right (LR) direction. The change in signal-to-noise ratio (SNR) was measured in phantom and in vivo.The clinical treatment plan, created on the image with CB, was transferred and recalculated on the image without the CB. Dose metrics for the targets (planning- and clinical target volume) and organs at risks (OAR) were analyzed. Results There was a statistically significant increase in SNR in-vivo (median 21 %, p = 0.002) when removing the CB. Anatomical differences after removing the CB in patients were -1.5 mm in AP (median change) and + 2.5 mm in LR direction. Dosimetric differences for the target structures were clinically negligible, but statistically significant. The difference in target mean doses were 0.2 % (both p = 0.004) of the prescribed dose. No dosimetric differences were observed for the OAR, except for the penile bulb. Conclusions We concluded that anatomical change and dosimetric differences, originating from scanning without CB were minor. The CB can thereby be removed from the workflow, enabling easier patient positioning and increased SNR when using lightweight coils.
Collapse
Affiliation(s)
- Jonas Scherman
- Department of Hematology, Oncology, and Radiation Physics Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
| | - Sacha af Wetterstedt
- Department of Hematology, Oncology, and Radiation Physics Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
| | - Emilia Persson
- Department of Hematology, Oncology, and Radiation Physics Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Carl Bertil Laurells gata 9, Malmö 205 02, Sweden
| | - Lars E. Olsson
- Department of Hematology, Oncology, and Radiation Physics Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Carl Bertil Laurells gata 9, Malmö 205 02, Sweden
| | - Christian Jamtheim Gustafsson
- Department of Hematology, Oncology, and Radiation Physics Skåne University Hospital, Klinikgatan 5, Lund 221 85, Sweden
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Carl Bertil Laurells gata 9, Malmö 205 02, Sweden
| |
Collapse
|
38
|
Nousiainen K, Santurio GV, Lundahl N, Cronholm R, Siversson C, Edmund JM. Evaluation of MRI-only based online adaptive radiotherapy of abdominal region on MR-linac. J Appl Clin Med Phys 2023; 24:e13838. [PMID: 36347050 PMCID: PMC10018672 DOI: 10.1002/acm2.13838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/30/2022] [Accepted: 10/18/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE A hybrid magnetic resonance linear accelerator (MRL) can perform magnetic resonance imaging (MRI) with high soft-tissue contrast to be used for online adaptive radiotherapy (oART). To obtain electron densities needed for the oART dose calculation, a computed tomography (CT) is often deformably registered to MRI. Our aim was to evaluate an MRI-only based synthetic CT (sCT) generation as an alternative to the deformed CT (dCT)-based oART in the abdominal region. METHODS The study data consisted of 57 patients who were treated on a 0.35 T MRL system mainly for abdominal tumors. Simulation MRI-CT pairs of 43 patients were used for training and validation of a prototype convolutional neural network sCT-generation algorithm, based on HighRes3DNet, for the abdominal region. For remaining test patients, sCT images were produced from simulation MRIs and daily MRIs. The dCT-based plans were re-calculated on sCT with identical calculation parameters. The sCT and dCT were compared in terms of geometric agreement and calculated dose. RESULTS The mean and one standard deviation of the geometric agreement metrics over dCT-sCT-pairs were: mean error of 8 ± 10 HU, mean absolute error of 49 ± 10 HU, and Dice similarity coefficient of 55 ± 12%, 60 ± 5%, and 82 ± 15% for bone, fat, and lung tissues, respectively. The dose differences between the sCT and dCT-based dose for planning target volumes were 0.5 ± 0.9%, 0.6 ± 0.8%, and 0.5 ± 0.8% at D2% , D50% , and D98% in physical dose and 0.8 ± 1.4%, 0.8 ± 1.2%, and 0.6 ± 1.1% in biologically effective dose (BED). For organs-at-risk, the dose differences of all evaluated dose-volume histogram points were within [-4.5%, 7.8%] and [-1.1 Gy, 3.5 Gy] in both physical dose and BED. CONCLUSIONS The geometric agreement metrics were within typically reported values and most average relative dose differences were within 1%. Thus, an MRI-only sCT-based approach is a promising alternative to the current clinical practice of the abdominal oART on MRL.
Collapse
Affiliation(s)
- Katri Nousiainen
- Department of Physics, University of Helsinki, Helsinki, Finland.,HUS Cancer Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.,HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Grichar Valdes Santurio
- Department of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark
| | | | | | | | - Jens M Edmund
- Department of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark.,Nils Bohr Institute, Copenhagen University, Copenhagen, Denmark
| |
Collapse
|
39
|
Moore-Palhares D, Ho L, Lu L, Chugh B, Vesprini D, Karam I, Soliman H, Symons S, Leung E, Loblaw A, Myrehaug S, Stanisz G, Sahgal A, Czarnota GJ. Clinical implementation of magnetic resonance imaging simulation for radiation oncology planning: 5 year experience. Radiat Oncol 2023; 18:27. [PMID: 36750891 PMCID: PMC9903411 DOI: 10.1186/s13014-023-02209-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Accepted: 01/16/2023] [Indexed: 02/09/2023] Open
Abstract
PURPOSE Integrating magnetic resonance (MR) into radiotherapy planning has several advantages. This report details the clinical implementation of an MR simulation (MR-planning) program for external beam radiotherapy (EBRT) in one of North America's largest radiotherapy programs. METHODS AND MATERIALS An MR radiotherapy planning program was developed and implemented at Sunnybrook Health Sciences Center in 2016 with two dedicated wide-bore MR platforms (1.5 and 3.0 Tesla). Planning MR was sequentially implemented every 3 months for separate treatment sites, including the central nervous system (CNS), gynecologic (GYN), head and neck (HN), genitourinary (GU), gastrointestinal (GI), breast, and brachial plexus. Essential protocols and processes were detailed in this report, including clinical workflow, optimized MR-image acquisition protocols, MR-adapted patient setup, strategies to overcome risks and challenges, and an MR-planning quality assurance program. This study retrospectively reviewed simulation site data for all MR-planning sessions performed for EBRT over the past 5 years. RESULTS From July 2016 to December 2021, 8798 MR-planning sessions were carried out, which corresponds to 25% of all computer tomography (CT) simulations (CT-planning) performed during the same period at our institution. There was a progressive rise from 80 MR-planning sessions in 2016 to 1126 in 2017, 1492 in 2018, 1824 in 2019, 2040 in 2020, and 2236 in 2021. As a result, the relative number of planning MR/CT increased from 3% of all planning sessions in 2016 to 36% in 2021. The most common site of MR-planning was CNS (49%), HN (13%), GYN (12%), GU (12%), and others (8%). CONCLUSION Detailed clinical processes and protocols of our MR-planning program were presented, which have been improved over more than 5 years of robust experience. Strategies to overcome risks and challenges in the implementation process are highlighted. Our work provides details that can be used by institutions interested in implementing an MR-planning program.
Collapse
Affiliation(s)
- Daniel Moore-Palhares
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada ,grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada
| | - Ling Ho
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada
| | - Lin Lu
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada
| | - Brige Chugh
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada ,grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada
| | - Danny Vesprini
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Irene Karam
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Hany Soliman
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Sean Symons
- grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada ,grid.413104.30000 0000 9743 1587Department of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - Eric Leung
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Andrew Loblaw
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Sten Myrehaug
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Greg Stanisz
- grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada
| | - Arjun Sahgal
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada
| | - Gregory J. Czarnota
- grid.413104.30000 0000 9743 1587Department of Radiation Oncology, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, T2, Toronto, ON M4N3M5 Canada ,grid.17063.330000 0001 2157 2938Department of Radiation Oncology, University of Toronto, Toronto, Canada ,grid.17063.330000 0001 2157 2938Physical Sciences, Sunnybrook Research Institute, Toronto, Canada ,grid.17063.330000 0001 2157 2938Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
40
|
Bryant JM, Sim AJ, Feygelman V, Latifi K, Rosenberg SA. Adaptive hypofractionted and stereotactic body radiotherapy for lung tumors with real-time MRI guidance. Front Oncol 2023; 13:1061854. [PMID: 36776319 PMCID: PMC9911810 DOI: 10.3389/fonc.2023.1061854] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 01/03/2023] [Indexed: 01/28/2023] Open
Abstract
The treatment of central and ultracentral lung tumors with radiotherapy remains an ongoing clinical challenge. The risk of Grade 5 toxicity with ablative radiotherapy doses to these high-risk regions is significant as shown in recent prospective studies. Magnetic resonance (MR) image-guided adaptive radiotherapy (MRgART) is a new technology and may allow the delivery of ablative radiotherapy to these high-risk regions safely. MRgART is able to achieve this by utilizing small treatment margins, real-time gating/tracking and on-table plan adaptation to maintain dose to the tumor but limit dose to critical structures. The process of MRgART is complex and has nuances and challenges for the treatment of lung tumors. We outline the critical steps needed for appropriate delivery of MRgART for lung tumors safely and effectively.
Collapse
Affiliation(s)
- John M. Bryant
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Austin J. Sim
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States,Department of Radiation Oncology, Comprehensive Cancer Center – The James Cancer Hospital, Columbus, OH, United States
| | - Vladimir Feygelman
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Kujtim Latifi
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States
| | - Stephen A. Rosenberg
- Department of Radiation Oncology, H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL, United States,*Correspondence: Stephen A. Rosenberg,
| |
Collapse
|
41
|
McDonald BA, Zachiu C, Christodouleas J, Naser MA, Ruschin M, Sonke JJ, Thorwarth D, Létourneau D, Tyagi N, Tadic T, Yang J, Li XA, Bernchou U, Hyer DE, Snyder JE, Bubula-Rehm E, Fuller CD, Brock KK. Dose accumulation for MR-guided adaptive radiotherapy: From practical considerations to state-of-the-art clinical implementation. Front Oncol 2023; 12:1086258. [PMID: 36776378 PMCID: PMC9909539 DOI: 10.3389/fonc.2022.1086258] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 12/21/2022] [Indexed: 01/27/2023] Open
Abstract
MRI-linear accelerator (MR-linac) devices have been introduced into clinical practice in recent years and have enabled MR-guided adaptive radiation therapy (MRgART). However, by accounting for anatomical changes throughout radiation therapy (RT) and delivering different treatment plans at each fraction, adaptive radiation therapy (ART) highlights several challenges in terms of calculating the total delivered dose. Dose accumulation strategies-which typically involve deformable image registration between planning images, deformable dose mapping, and voxel-wise dose summation-can be employed for ART to estimate the delivered dose. In MRgART, plan adaptation on MRI instead of CT necessitates additional considerations in the dose accumulation process because MRI pixel values do not contain the quantitative information used for dose calculation. In this review, we discuss considerations for dose accumulation specific to MRgART and in relation to current MR-linac clinical workflows. We present a general dose accumulation framework for MRgART and discuss relevant quality assurance criteria. Finally, we highlight the clinical importance of dose accumulation in the ART era as well as the possible ways in which dose accumulation can transform clinical practice and improve our ability to deliver personalized RT.
Collapse
Affiliation(s)
- Brigid A. McDonald
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Cornel Zachiu
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, Netherlands
| | | | - Mohamed A. Naser
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Mark Ruschin
- Department of Radiation Oncology, University of Toronto, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tuebingen, Tuebingen, Germany
| | - Daniel Létourneau
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Neelam Tyagi
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, United States
| | - Tony Tadic
- Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON, Canada
- Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Jinzhong Yang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - X. Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| | - Uffe Bernchou
- Laboratory of Radiation Physics, Department of Oncology, Odense University Hospital, Odense, Denmark
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Daniel E. Hyer
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | - Jeffrey E. Snyder
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | | | - Clifton D. Fuller
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Kristy K. Brock
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| |
Collapse
|
42
|
Zaridis DI, Mylona E, Tachos N, Pezoulas VC, Grigoriadis G, Tsiknakis N, Marias K, Tsiknakis M, Fotiadis DI. Region-adaptive magnetic resonance image enhancement for improving CNN-based segmentation of the prostate and prostatic zones. Sci Rep 2023; 13:714. [PMID: 36639671 PMCID: PMC9837765 DOI: 10.1038/s41598-023-27671-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 01/05/2023] [Indexed: 01/14/2023] Open
Abstract
Automatic segmentation of the prostate of and the prostatic zones on MRI remains one of the most compelling research areas. While different image enhancement techniques are emerging as powerful tools for improving the performance of segmentation algorithms, their application still lacks consensus due to contrasting evidence regarding performance improvement and cross-model stability, further hampered by the inability to explain models' predictions. Particularly, for prostate segmentation, the effectiveness of image enhancement on different Convolutional Neural Networks (CNN) remains largely unexplored. The present work introduces a novel image enhancement method, named RACLAHE, to enhance the performance of CNN models for segmenting the prostate's gland and the prostatic zones. The improvement in performance and consistency across five CNN models (U-Net, U-Net++, U-Net3+, ResU-net and USE-NET) is compared against four popular image enhancement methods. Additionally, a methodology is proposed to explain, both quantitatively and qualitatively, the relation between saliency maps and ground truth probability maps. Overall, RACLAHE was the most consistent image enhancement algorithm in terms of performance improvement across CNN models with the mean increase in Dice Score ranging from 3 to 9% for the different prostatic regions, while achieving minimal inter-model variability. The integration of a feature driven methodology to explain the predictions after applying image enhancement methods, enables the development of a concrete, trustworthy automated pipeline for prostate segmentation on MR images.
Collapse
Affiliation(s)
- Dimitrios I Zaridis
- Biomedical Research Institute, Foundation for Research and Technology Hellas (FORTH), Ioannina, Greece
| | - Eugenia Mylona
- Biomedical Research Institute, Foundation for Research and Technology Hellas (FORTH), Ioannina, Greece
| | - Nikolaos Tachos
- Biomedical Research Institute, Foundation for Research and Technology Hellas (FORTH), Ioannina, Greece
| | - Vasileios C Pezoulas
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, Ioannina, Greece
| | - Grigorios Grigoriadis
- Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, Ioannina, Greece
| | - Nikos Tsiknakis
- Institute of Computer Science, Foundation for Research and Technology Hellas (FORTH), Heraklion, Greece
| | - Kostas Marias
- Institute of Computer Science, Foundation for Research and Technology Hellas (FORTH), Heraklion, Greece.,Department of Electrical and Computer Engineering, Hellenic Mediterranean University, Heraklion, Greece
| | - Manolis Tsiknakis
- Institute of Computer Science, Foundation for Research and Technology Hellas (FORTH), Heraklion, Greece.,Department of Electrical and Computer Engineering, Hellenic Mediterranean University, Heraklion, Greece
| | - Dimitrios I Fotiadis
- Biomedical Research Institute, Foundation for Research and Technology Hellas (FORTH), Ioannina, Greece. .,Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science and Engineering, University of Ioannina, Ioannina, Greece.
| |
Collapse
|
43
|
Hyuk Choi J, Asadi B, Simpson J, Dowling JA, Chalup S, Welsh J, Greer P. Investigation of a water equivalent depth method for dosimetric accuracy evaluation of synthetic CT. Phys Med 2023; 105:102507. [PMID: 36535236 DOI: 10.1016/j.ejmp.2022.11.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 11/24/2022] [Accepted: 11/26/2022] [Indexed: 12/23/2022] Open
Abstract
PURPOSE To provide a metric that reflects the dosimetric utility of the synthetic CT (sCT) and can be rapidly determined. METHODS Retrospective CT and atlas-based sCT of 62 (53 IMRT and 9 VMAT) prostate cancer patients were used. For image similarity measurements, the sCT and reference CT (rCT) were aligned using clinical registration parameters. Conventional image similarity metrics including the mean absolute error (MAE) and mean error (ME) were calculated. The water equivalent depth (WED) was automatically determined for each patient on the rCT and sCT as the distance from the skin surface to the treatment plan isocentre at 36 equidistant gantry angles, and the mean WED difference (ΔWED¯) between the two scans was calculated. Doses were calculated on each scan pair for the clinical plan in the treatment planning system. The image similarity measurements and ΔWED¯ were then compared to the isocentre dose difference (ΔDiso) between the two scans. RESULTS While no particular relationship to dose was observed for the other image similarity metrics, the ME results showed a linear trend against ΔDiso with R2 = 0.6, and the 95 % prediction interval for ΔDiso between -1.2 and 1 %. The ΔWED¯ results showed an improved linear trend (R2 = 0.8) with a narrower 95 % prediction interval from -0.8 % to 0.8 %. CONCLUSION ΔWED¯ highly correlates with ΔDiso for the reference and synthetic CT scans. This is easy to calculate automatically and does not require time-consuming dose calculations. Therefore, it can facilitate the process of developing and evaluating new sCT generation algorithms.
Collapse
Affiliation(s)
- Jae Hyuk Choi
- School of Information and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia.
| | - Behzad Asadi
- Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, New South Wales, Australia
| | - John Simpson
- Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, New South Wales, Australia
| | - Jason A Dowling
- School of Information and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia; Commonwealth Scientific and Industrial Research Organisation, Australian E-Health Research Centre, Herston, Queensland, Australia
| | - Stephan Chalup
- School of Information and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia
| | - James Welsh
- School of Engineering, University of Newcastle, Newcastle, New South Wales, Australia
| | - Peter Greer
- School of Information and Physical Sciences, University of Newcastle, Newcastle, New South Wales, Australia; Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, New South Wales, Australia
| |
Collapse
|
44
|
Devi S, Bakshi S, Sahoo MN. Effect of situational and instrumental distortions on the classification of brain MR images. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2022.104177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
45
|
Persson E, Svanberg N, Scherman J, Jamtheim Gustafsson C, Fridhammar A, Hjalte F, Bäck S, Nilsson P, Gunnlaugsson A, Olsson LE. MRI-only radiotherapy from an economic perspective: Can new techniques in prostate cancer treatment be cost saving? Clin Transl Radiat Oncol 2022; 38:183-187. [DOI: 10.1016/j.ctro.2022.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 10/16/2022] [Accepted: 11/19/2022] [Indexed: 11/23/2022] Open
|
46
|
Gurney-Champion OJ, Landry G, Redalen KR, Thorwarth D. Potential of Deep Learning in Quantitative Magnetic Resonance Imaging for Personalized Radiotherapy. Semin Radiat Oncol 2022; 32:377-388. [DOI: 10.1016/j.semradonc.2022.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
47
|
Magnetic Resonance Imaging–guided Focal Boost to Intraprostatic Lesions Using External Beam Radiotherapy for Localized Prostate Cancer: A Systematic Review and Meta-analysis. Eur Urol Oncol 2022. [DOI: 10.1016/j.euo.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
48
|
Hsu SH, Han Z, Leeman JE, Hu YH, Mak RH, Sudhyadhom A. Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer. Front Oncol 2022; 12:969463. [PMID: 36212472 PMCID: PMC9539763 DOI: 10.3389/fonc.2022.969463] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 08/26/2022] [Indexed: 11/21/2022] Open
Abstract
Current MRI-guided adaptive radiotherapy (MRgART) workflows require fraction-specific electron and/or mass density maps, which are created by deformable image registration (DIR) between the simulation CT images and daily MR images. Manual density overrides may also be needed where DIR-produced results are inaccurate. This approach slows the adaptive radiotherapy workflow and introduces additional dosimetric uncertainties, especially in the presence of the magnetic field. This study investigated a method based on a conditional generative adversarial network (cGAN) with a multi-planar method to generate synthetic CT images from low-field MR images to improve efficiency in MRgART workflows for prostate cancer. Fifty-seven male patients, who received MRI-guided radiation therapy to the pelvis using the ViewRay MRIdian Linac, were selected. Forty-five cases were randomly assigned to the training cohort with the remaining twelve cases assigned to the validation/testing cohort. All patient datasets had a semi-paired DIR-deformed CT-sim image and 0.35T MR image acquired using a true fast imaging with steady-state precession (TrueFISP) sequence. Synthetic CT images were compared with deformed CT images to evaluate image quality and dosimetric accuracy. To evaluate the dosimetric accuracy of this method, clinical plans were recalculated on synthetic CT images in the MRIdian treatment planning system. Dose volume histograms for planning target volumes (PTVs) and organs-at-risk (OARs) and dose distributions using gamma analyses were evaluated. The mean-absolute-errors (MAEs) in CT numbers were 30.1 ± 4.2 HU, 19.6 ± 2.3 HU and 158.5 ± 26.0 HU for the whole pelvis, soft tissue, and bone, respectively. The peak signal-to-noise ratio was 35.2 ± 1.7 and the structural index similarity measure was 0.9758 ± 0.0035. The dosimetric difference was on average less than 1% for all PTV and OAR metrics. Plans showed good agreement with gamma pass rates of 99% and 99.9% for 1%/1 mm and 2%/2 mm, respectively. Our study demonstrates the potential of using synthetic CT images created with a multi-planar cGAN method from 0.35T MRI TrueFISP images for the MRgART treatment of prostate radiotherapy. Future work will validate the method in a large cohort of patients and investigate the limitations of the method in the adaptive workflow.
Collapse
|
49
|
Zhang L, Yin FF, Lu K, Moore B, Han S, Cai J. Improving liver tumor image contrast and synthesizing novel tissue contrasts by adaptive multiparametric MRI fusion. PRECISION RADIATION ONCOLOGY 2022; 6:190-198. [PMID: 36590077 PMCID: PMC9797133 DOI: 10.1002/pro6.1167] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 06/23/2022] [Indexed: 01/05/2023] Open
Abstract
Purpose Multiparametric MRI contains rich and complementary anatomical and functional information, which is often utilized separately. This study aims to propose an adaptive multiparametric MRI (mpMRI) fusion method and examine its capability in improving tumor contrast and synthesizing novel tissue contrasts among liver cancer patients. Methods An adaptive mpMRI fusion method was developed with five components: image pre-processing, fusion algorithm, database, adaptation rules, and fused MRI. Linear-weighted summation algorithm was used for fusion. Weight-driven and feature-driven adaptations were designed for different applications. A clinical-friendly graphic-user-interface (GUI) was developed in Matlab and used for mpMRI fusion. Twelve liver cancer patients and a digital human phantom were included in the study. Synthesis of novel image contrast and enhancement of image signal and contrast were examined in patient cases. Tumor contrast-to-noise ratio (CNR) and liver signal-to-noise ratio (SNR) were evaluated and compared before and after mpMRI fusion. Results The fusion platform was applicable in both XCAT phantom and patient cases. Novel image contrasts, including enhancement of soft-tissue boundary, vertebral body, tumor, and composition of multiple image features in a single image were achieved. Tumor CNR improved from -1.70 ± 2.57 to 4.88 ± 2.28 (p < 0.0001) for T1-w, from 3.39 ± 1.89 to 7.87 ± 3.47 (p < 0.01) for T2-w, and from 1.42 ± 1.66 to 7.69 ± 3.54 (p < 0.001) for T2/T1-w MRI. Liver SNR improved from 2.92 ± 2.39 to 9.96 ± 8.60 (p < 0.05) for DWI. The coefficient of variation (CV) of tumor CNR lowered from 1.57, 0.56, and 1.17 to 0.47, 0.44, and 0.46 for T1-w, T2-w and T2/T1-w MRI, respectively. Conclusion A multiparametric MRI fusion method was proposed and a prototype was developed. The method showed potential in improving clinically relevant features such as tumor contrast and liver signal. Synthesis of novel image contrasts including the composition of multiple image features into single image set was achieved.
Collapse
Affiliation(s)
- Lei Zhang
- Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710, USA
- Medical Physics Graduate Program, Duke Kunshan University, Kunshan, Jiangsu, 215316 China
| | - Fang-Fang Yin
- Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710, USA
- Medical Physics Graduate Program, Duke Kunshan University, Kunshan, Jiangsu, 215316 China
| | - Ke Lu
- Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710, USA
| | - Brittany Moore
- Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710, USA
| | - Silu Han
- Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705, USA
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710, USA
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| |
Collapse
|
50
|
Retif P, Djibo Sidikou A, Mathis C, Letellier R, Verrecchia-Ramos E, Dupres R, Michel X. Evaluation of the ability of the Brainlab Elements Cranial Distortion Correction algorithm to correct clinically relevant MRI distortions for cranial SRT. Strahlenther Onkol 2022; 198:907-918. [PMID: 35980455 DOI: 10.1007/s00066-022-01988-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Accepted: 07/10/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE Cranial stereotactic radiotherapy (SRT) requires highly accurate lesion delineation. However, MRI can have significant inherent geometric distortions. We investigated how well the Elements Cranial Distortion Correction algorithm of Brainlab (Munich, Germany) corrects the distortions in MR image-sets of a phantom and patients. METHODS A non-distorted reference computed tomography image-set of a CIRS Model 603-GS (CIRS, Norfolk, VA, USA) phantom was acquired. Three-dimensional T1-weighted images were acquired with five MRI scanners and reconstructed with vendor-derived distortion correction. Some were reconstructed without correction to generate heavily distorted image-sets. All MR image-sets were corrected with the Brainlab algorithm relative to the computed tomography acquisition. CIRS Distortion Check software measured the distortion in each image-set. For all uncorrected and corrected image-sets, the control points that exceeded the 0.5-mm clinically relevant distortion threshold and the distortion maximum, mean, and standard deviation were recorded. Empirical cumulative distribution functions (eCDF) were plotted. Intraclass correlation coefficient (ICC) was calculated. The algorithm was evaluated with 10 brain metastases using Dice similarity coefficients (DSC). RESULTS The algorithm significantly reduced mean and standard deviation distortion in all image-sets. It reduced the maximum distortion in the heavily distorted image-sets from 2.072 to 1.059 mm and the control points with > 0.5-mm distortion fell from 50.2% to 4.0%. Before and especially after correction, the eCDFs of the four repeats were visually similar. ICC was 0.812 (excellent-good agreement). The algorithm increased the DSCs for all patients and image-sets. CONCLUSION The Brainlab algorithm significantly and reproducibly ameliorated MRI distortion, even with heavily distorted images. Thus, it increases the accuracy of cranial SRT lesion delineation. After further testing, this tool may be suitable for SRT of small lesions.
Collapse
Affiliation(s)
- Paul Retif
- Medical Physics Unit, CHR Metz-Thionville, Metz, France. .,Université de Lorraine, CNRS, CRAN, 54000, Nancy, France.
| | | | | | | | | | - Rémi Dupres
- Medical Imaging Department, CHR Metz-Thionville, Metz, France
| | - Xavier Michel
- Radiation Therapy Department, CHR Metz-Thionville, Metz, France
| |
Collapse
|