1
|
Seo M, Shin M, Noh G, Yoo SS, Yoon K. Multi-modal networks for real-time monitoring of intracranial acoustic field during transcranial focused ultrasound therapy. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 257:108458. [PMID: 39437458 DOI: 10.1016/j.cmpb.2024.108458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 09/22/2024] [Accepted: 10/07/2024] [Indexed: 10/25/2024]
Abstract
BACKGROUND AND OBJECTIVE Transcranial focused ultrasound (tFUS) is an emerging non-invasive therapeutic technology that offers new brain stimulation modality. Precise localization of the acoustic focus to the desired brain target throughout the procedure is needed to ensure the safety and effectiveness of the treatment, but acoustic distortion caused by the skull poses a challenge. Although computational methods can provide the estimated location and shape of the focus, the computation has not reached sufficient speed for real-time inference, which is demanded in real-world clinical situations. Leveraging the advantages of deep learning, we propose multi-modal networks capable of generating intracranial pressure map in real-time. METHODS The dataset consisted of free-field pressure maps, intracranial pressure maps, medical images, and transducer placements was obtained from 11 human subjects. The free-field and intracranial pressure maps were computed using the k-space method. We developed network models based on convolutional neural networks and the Swin Transformer, featuring a multi-modal encoder and a decoder. RESULTS Evaluations on foreseen data achieved high focal volume conformity of approximately 93% for both computed tomography (CT) and magnetic resonance (MR) data. For unforeseen data, the networks achieved the focal volume conformity of 88% for CT and 82% for MR. The inference time of the proposed networks was under 0.02 s, indicating the feasibility for real-time simulation. CONCLUSIONS The results indicate that our networks can effectively and precisely perform real-time simulation of the intracranial pressure map during tFUS applications. Our work will enhance the safety and accuracy of treatments, representing significant progress for low-intensity focused ultrasound (LIFU) therapies.
Collapse
Affiliation(s)
- Minjee Seo
- Yonsei University, School of Mathematics and Computing (Computational Science and Engineering), Seoul, 03722, Republic of Korea
| | - Minwoo Shin
- Yonsei University, School of Mathematics and Computing (Computational Science and Engineering), Seoul, 03722, Republic of Korea
| | - Gunwoo Noh
- Korea University, School of Mechanical Engineering, Seoul, 02841, Republic of Korea
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, 02115, MA, USA
| | - Kyungho Yoon
- Yonsei University, School of Mathematics and Computing (Computational Science and Engineering), Seoul, 03722, Republic of Korea.
| |
Collapse
|
2
|
Rahpeima R, Lin CA. A comprehensive numerical procedure for high-intensity focused ultrasound ablation of breast tumour on an anatomically realistic breast phantom. PLoS One 2024; 19:e0310899. [PMID: 39352893 PMCID: PMC11444401 DOI: 10.1371/journal.pone.0310899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 09/09/2024] [Indexed: 10/04/2024] Open
Abstract
High-Intensity Focused Ultrasound (HIFU) as a promising and impactful modality for breast tumor ablation, entails the precise focalization of high-intensity ultrasonic waves onto the tumor site, culminating in the generation of extreme heat, thus ablation of malignant tissues. In this paper, a comprehensive three-dimensional (3D) Finite Element Method (FEM)-based numerical procedure is introduced, which provides exceptional capacity for simulating the intricate multiphysics phenomena associated with HIFU. Furthermore, the application of numerical procedures to an anatomically realistic breast phantom (ARBP) has not been explored before. The integrity of the present numerical procedure has been established through rigorous validation, incorporating comparative assessments with previous two-dimensional (2D) simulations and empirical data. For ARBP ablation, the administration of a 0.1 MPa pressure input pulse at a frequency of 1.5 MHz, sustained at the focal point for 10 seconds, manifests an ensuing temperature elevation to 80°C. It is noteworthy that, in contrast, the prior 2D simulation using a 2D phantom geometry reached just 72°C temperature under the identical treatment regimen, underscoring the insufficiency of 2D models, ascribed to their inherent limitations in spatially representing acoustic energy, which compromises their overall effectiveness. To underscore the versatility of this numerical platform, a simulation of a more clinically relevant HIFU therapy procedure has been conducted. This scenario involves the repositioning of the ultrasound focal point to three separate lesions, each spaced at 3 mm intervals, with ultrasound exposure durations of 6 seconds each and a 5-second interval for movement between focal points. This approach resulted in a more uniform high-temperature distribution at different areas of the tumour, leading to the ablation of almost all parts of the tumour, including its verges. In the end, the effects of different abnormal tissue shapes are investigated briefly as well. For solid mass tumors, 67.67% was successfully ablated with one lesion, while rim-enhancing tumors showed only 34.48% ablation and non-mass enhancement tumors exhibited 20.32% ablation, underscoring the need for multiple lesions and tailored treatment plans for more complex cases.
Collapse
Affiliation(s)
- Reza Rahpeima
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| | - Chao-An Lin
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| |
Collapse
|
3
|
Dagommer M, Daneshzand M, Nummemnaa A, Guerin B. Robust deep learning estimation of cortical bone porosity from MR T1-weighted images for individualized transcranial focused ultrasound planning. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2024:2024.07.18.24310644. [PMID: 39072036 PMCID: PMC11275664 DOI: 10.1101/2024.07.18.24310644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/30/2024]
Abstract
Objective Transcranial focused ultrasound (tFUS) is an emerging neuromodulation approach that has been demonstrated in animals but is difficult to translate to humans because of acoustic attenuation and scattering in the skull. Optimal dose delivery requires subject-specific skull porosity estimates which has traditionally been done using CT. We propose a deep learning (DL) estimation of skull porosity from T1-weighted MRI images which removes the need for radiation-inducing CT scans. Approach We evaluate the impact of different DL approaches, including network architecture, input size and dimensionality, multichannel inputs, data augmentation, and loss functions. We also propose back-propagation in the mask (BIM), a method whereby only voxels inside the skull mask contribute to training. We evaluate the robustness of the best model to input image noise and MRI acquisition parameters and propagate porosity estimation errors in thousands of beam propagation scenarios. Main results Our best performing model is a cGAN with a ResNet-9 generator with 3D 64×64×64 inputs trained with L1 and L2 losses. The model achieved a mean absolute error of 6.9% in the test set, compared to 9.5% with the pseudo-CT of Izquierdo et al. (38% improvement) and 9.4% with the generic pixel-to-pixel image translation cGAN pix2pix (36% improvement). Acoustic dose distributions in the thalamus were more accurate with our approach than with the pseudo-CT approach of both Burgos et al. and Izquierdo et al, resulting in near-optimal treatment planning and dose estimation at all frequencies compared to CT (reference). Significance Our DL approach porosity estimates with ~7% error, is robust to input image noise and MRI acquisition parameters (sequence, coils, field strength) and yields near-optimal treatment planning and dose estimates for both central (thalamus) and lateral brain targets (amygdala) in the 200-1000 kHz frequency range.
Collapse
Affiliation(s)
- Matthieu Dagommer
- École Supérieure de Physique et de Chimie Industrielles de la Ville de Paris (ESPCI), Paris France
| | - Mohammad Daneshzand
- Harvard Medical School, Boston MA
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown MA
| | - Aapo Nummemnaa
- Harvard Medical School, Boston MA
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown MA
| | - Bastien Guerin
- Harvard Medical School, Boston MA
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown MA
| |
Collapse
|
4
|
Daneshzand M, Guerin B, Kotlarz P, Chou T, Dougherty DD, Edlow BL, Nummenmaa A. Model-based navigation of transcranial focused ultrasound neuromodulation in humans: Application to targeting the amygdala and thalamus. Brain Stimul 2024; 17:958-969. [PMID: 39094682 PMCID: PMC11367617 DOI: 10.1016/j.brs.2024.07.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 07/22/2024] [Accepted: 07/29/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND Transcranial focused ultrasound (tFUS) neuromodulation has shown promise in animals but is challenging to translate to humans because of the thicker skull that heavily scatters ultrasound waves. OBJECTIVE We develop and disseminate a model-based navigation (MBN) tool for acoustic dose delivery in the presence of skull aberrations that is easy to use by non-specialists. METHODS We pre-compute acoustic beams for thousands of virtual transducer locations on the scalp of the subject under study. We use the hybrid angular spectrum solver mSOUND, which runs in ∼4 s per solve per CPU yielding pre-computation times under 1 h for scalp meshes with up to 4000 faces and a parallelization factor of 5. We combine this pre-computed set of beam solutions with optical tracking, thus allowing real-time display of the tFUS beam as the operator freely navigates the transducer around the subject' scalp. We assess the impact of MBN versus line-of-sight targeting (LOST) positioning in simulations of 13 subjects. RESULTS Our navigation tool has a display refresh rate of ∼10 Hz. In our simulations, MBN increased the acoustic dose in the thalamus and amygdala by 8-67 % compared to LOST and avoided complete target misses that affected 10-20 % of LOST cases. MBN also yielded a lower variability of the deposited dose across subjects than LOST. CONCLUSIONS MBN may yield greater and more consistent (less variable) ultrasound dose deposition than transducer placement with line-of-sight targeting, and thus could become a helpful tool to improve the efficacy of tFUS neuromodulation.
Collapse
Affiliation(s)
- Mohammad Daneshzand
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA
| | - Bastien Guerin
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA.
| | - Parker Kotlarz
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA
| | - Tina Chou
- Harvard Medical School, Boston, MA, USA; Department of Psychiatry, Massachusetts General Hospital, Charlestown, MA, USA
| | - Darin D Dougherty
- Harvard Medical School, Boston, MA, USA; Department of Psychiatry, Massachusetts General Hospital, Charlestown, MA, USA
| | - Brian L Edlow
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA; Center for Neurotechnology and Neurorecovery, Department of Neurology, Massachusetts General Hospital, Boston, MA, USA
| | - Aapo Nummenmaa
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA
| |
Collapse
|
5
|
Antoniou A, Evripidou N, Damianou C. Focused ultrasound heating in brain tissue/skull phantoms with 1 MHz single-element transducer. J Ultrasound 2024; 27:263-274. [PMID: 37517052 PMCID: PMC11178743 DOI: 10.1007/s40477-023-00810-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 07/09/2023] [Indexed: 08/01/2023] Open
Abstract
PURPOSE The study aims to provide insights on the practicality of using single-element transducers for transcranial Focused Ultrasound (tFUS) thermal applications. METHODS FUS sonications were performed through skull phantoms embedding agar-based tissue mimicking gels using a 1 MHz single-element spherically focused transducer. The skull phantoms were 3D printed with Acrylonitrile Butadiene Styrene (ABS) and Resin thermoplastics having the exact skull bone geometry of a healthy volunteer. The temperature field distribution during and after heating was monitored in a 3 T Magnetic Resonance Imaging (MRI) scanner using MR thermometry. The effect of the skull's thickness on intracranial heating was investigated. RESULTS A single FUS sonication at focal acoustic intensities close to 1580 W/cm2 for 60 s in free field heated up the agar phantom to ablative temperatures reaching about 90 °C (baseline of 37 °C). The ABS skull strongly blocked the ultrasonic waves, resulting in zero temperature increase within the phantom. Considerable heating was achieved through the Resin skull, but it remained at hyperthermia levels. Conversely, tFUS through a 1 mm Resin skull showed enhanced ultrasonic penetration and heating, with the focal temperature reaching 70 °C. CONCLUSIONS The ABS skull demonstrated poorer performance in terms of tFUS compared to the Resin skull owing to its higher ultrasonic attenuation and porosity. The thin Resin phantom of 1 mm thickness provided an efficient acoustic window for delivering tFUS and heating up deep phantom areas. The results of such studies could be particularly useful for accelerating the establishment of a wider range of tFUS applications.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus.
| |
Collapse
|
6
|
Cheng Z, Deng L, Lin Y, Zeng L, Ji X. Correction of a transcranial acoustic field using a transient ultrasound field visualization technique. OPTICS LETTERS 2023; 48:5915-5918. [PMID: 37966751 DOI: 10.1364/ol.505081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 10/24/2023] [Indexed: 11/16/2023]
Abstract
Ultrasound, due to its noninvasive nature, has the potential to enhance or suppress neural activity, making it highly promising for regulating intractable brain disorders. Precise ultrasound stimulation is crucial for improving the efficiency of neural modulation and studying its mechanisms. However, the presence of the skull can cause distortion in the ultrasound field, thereby affecting the accuracy of stimulation. Existing correction methods primarily rely on magnetic resonance guidance and numerical simulation. Due to the large size and high cost, the MR-guided transcranial ultrasound is difficult to be widely applied in small animals. The numerical simulation usually requires further validation and optimization before application, and the most effective method is to visualize the excited ultrasound field. However, the ultrasound field correction methods based on acoustic field visualization are still lacking. Therefore, a shadowgraph-based transient ultrasonic field visualization system is developed, and an ex vivo transcranial ultrasound field correction is performed. By visualizing the ultrasound field with or without a rat skull and then calculating the time difference of each element's ultrasound wavefront, the parameters for ultrasound field correction can be achieved. The experimental results show that this method can improve both the shape and the size of the focal spot, as well as enhance the acoustic pressure at the focus. Overall, the results demonstrate that the ultrasonic field visualization technology can effectively improve the transcranial ultrasound focusing effect and provide a new tool for achieving precise ultrasonic neural modulation.
Collapse
|
7
|
Park TY, Koh H, Lee W, Park SH, Chang WS, Kim H. Real-Time Acoustic Simulation Framework for tFUS: A Feasibility Study Using Navigation System. Neuroimage 2023; 282:120411. [PMID: 37844771 DOI: 10.1016/j.neuroimage.2023.120411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 10/10/2023] [Accepted: 10/13/2023] [Indexed: 10/18/2023] Open
Abstract
Transcranial focused ultrasound (tFUS), in which acoustic energy is focused on a small region in the brain through the skull, is a non-invasive therapeutic method with high spatial resolution and depth penetration. Image-guided navigation has been widely utilized to visualize the location of acoustic focus in the cranial cavity. However, this system is often inaccurate because of the significant aberrations caused by the skull. Therefore, acoustic simulations using a numerical solver have been widely adopted to compensate for this inaccuracy. Although the simulation can predict the intracranial acoustic pressure field, real-time application during tFUS treatment is almost impossible due to the high computational cost. In this study, we propose a neural network-based real-time acoustic simulation framework and test its feasibility by implementing a simulation-guided navigation (SGN) system. Real-time acoustic simulation is performed using a 3D conditional generative adversarial network (3D-cGAN) model featuring residual blocks and multiple loss functions. This network was trained by the conventional numerical acoustic simulation program (i.e., k-Wave). The SGN system is then implemented by integrating real-time acoustic simulation with a conventional image-guided navigation system. The proposed system can provide simulation results with a frame rate of 5 Hz (i.e., about 0.2 s), including all processing times. In numerical validation (3D-cGAN vs. k-Wave), the average peak intracranial pressure error was 6.8 ± 5.5%, and the average acoustic focus position error was 5.3 ± 7.7 mm. In experimental validation using a skull phantom (3D-cGAN vs. actual measurement), the average peak intracranial pressure error was 4.5%, and the average acoustic focus position error was 6.6 mm. These results demonstrate that the SGN system can predict the intracranial acoustic field according to transducer placement in real-time.
Collapse
Affiliation(s)
- Tae Young Park
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul 02792, Republic of Korea
| | - Heekyung Koh
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - Wonhye Lee
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - So Hee Park
- Department of Neurosurgery, Yeungnam University Medical Center, Daegu 42415, Republic of Korea
| | - Won Seok Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul 04527, Republic of Korea
| | - Hyungmin Kim
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul 02792, Republic of Korea.
| |
Collapse
|
8
|
Gao P, Sun Y, Zhang G, Li C, Wang L. A transducer positioning method for transcranial focused ultrasound treatment of brain tumors. Front Neurosci 2023; 17:1277906. [PMID: 37904813 PMCID: PMC10613465 DOI: 10.3389/fnins.2023.1277906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Accepted: 09/28/2023] [Indexed: 11/01/2023] Open
Abstract
Purpose As a non-invasive method for brain diseases, transcranial focused ultrasound (tFUS) offers higher spatial precision and regulation depth. Due to the altered path and intensity of sonication penetrating the skull, the focus and intensity in the skull are difficult to determine, making the use of ultrasound therapy for cancer treatment experimental and not widely available. The deficiency can be effectively addressed by numerical simulation methods, which enable the optimization of sonication modulation parameters and the determination of precise transducer positioning. Methods A 3D skull model was established using binarized brain CT images. The selection of the transducer matrix was performed using the radius positioning (RP) method after identifying the intracranial target region. Simulations were performed, encompassing acoustic pressure (AP), acoustic field, and temperature field, in order to provide compelling evidence of the safety of tFUS in sonication-induced thermal effects. Results It was found that the angle of sonication path to the coronal plane obtained at all precision and frequency models did not exceed 10° and 15° to the transverse plane. The results of thermal effects illustrated that the peak temperatures of tFUS were 43.73°C, which did not reach the point of tissue degeneration. Once positioned, tFUS effectively delivers a Full Width at Half Maximum (FWHM) stimulation that targets tumors with diameters of up to 3.72 mm in a one-off. The original precision model showed an attenuation of 24.47 ± 6.13 mm in length and 2.40 ± 1.42 mm in width for the FWHM of sonication after penetrating the skull. Conclusion The vector angles of the sonication path in each direction were determined based on the transducer positioning results. It has been suggested that when time is limited for precise transducer positioning, fixing the transducer on the horizontal surface of the target region can also yield positive results for stimulation. This framework used a new transducer localization method to offer a reliable basis for further research and offered new methods for the use of tFUS in brain tumor-related research.
Collapse
Affiliation(s)
- Penghao Gao
- Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Yue Sun
- Department of Biomedical Engineering, Shenyang University of Technology, Shenyang, Liaoning, China
| | - Gongsen Zhang
- Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| | - Chunsheng Li
- Department of Biomedical Engineering, Shenyang University of Technology, Shenyang, Liaoning, China
| | - Linlin Wang
- Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
- Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China
| |
Collapse
|
9
|
Yoo SS, Kim E, Kowsari K, Van Reet J, Kim HC, Yoon K. Non-invasive enhancement of intracortical solute clearance using transcranial focused ultrasound. Sci Rep 2023; 13:12339. [PMID: 37524783 PMCID: PMC10390479 DOI: 10.1038/s41598-023-39640-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Accepted: 07/28/2023] [Indexed: 08/02/2023] Open
Abstract
Transport of interstitial fluid and solutes plays a critical role in clearing metabolic waste from the brain. Transcranial application of focused ultrasound (FUS) has been shown to promote localized cerebrospinal fluid solute uptake into the brain parenchyma; however, its effects on the transport and clearance of interstitial solutes remain unknown. We demonstrate that pulsed application of low-intensity FUS to the rat brain enhances the transport of intracortically injected fluorescent tracers (ovalbumin and high molecular-weight dextran), yielding greater parenchymal tracer volume distribution compared to the unsonicated control group (ovalbumin by 40.1% and dextran by 34.6%). Furthermore, FUS promoted the drainage of injected interstitial ovalbumin to both superficial and deep cervical lymph nodes (cLNs) ipsilateral to sonication, with 78.3% higher drainage observed in the superficial cLNs compared to the non-sonicated hemisphere. The application of FUS increased the level of solute transport visible from the dorsal brain surface, with ~ 43% greater area and ~ 19% higher fluorescence intensity than the unsonicated group, especially in the pial surface ipsilateral to sonication. The sonication did not elicit tissue-level neuronal excitation, measured by an electroencephalogram, nor did it alter the molecular weight of the tracers. These findings suggest that nonthermal transcranial FUS can enhance advective transport of interstitial solutes and their subsequent removal in a completely non-invasive fashion, offering its potential non-pharmacological utility in facilitating clearance of waste from the brain.
Collapse
Affiliation(s)
- Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA.
| | - Evgenii Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
| | - Kavin Kowsari
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
| | - Jared Van Reet
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
| | - Hyun-Chul Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
- Department of Artificial Intelligence, Kyungpook National University, Daegu, Republic of Korea
| | - Kyungho Yoon
- School of Computational Science and Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
10
|
Kim HC, Lee W, Weisholtz DS, Yoo SS. Transcranial focused ultrasound stimulation of cortical and thalamic somatosensory areas in human. PLoS One 2023; 18:e0288654. [PMID: 37478086 PMCID: PMC10361523 DOI: 10.1371/journal.pone.0288654] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 06/30/2023] [Indexed: 07/23/2023] Open
Abstract
The effects of transcranial focused ultrasound (FUS) stimulation of the primary somatosensory cortex and its thalamic projection (i.e., ventral posterolateral nucleus) on the generation of electroencephalographic (EEG) responses were evaluated in healthy human volunteers. Stimulation of the unilateral somatosensory circuits corresponding to the non-dominant hand generated EEG evoked potentials across all participants; however, not all perceived stimulation-mediated tactile sensations of the hand. These FUS-evoked EEG potentials (FEP) were observed from both brain hemispheres and shared similarities with somatosensory evoked potentials (SSEP) from median nerve stimulation. Use of a 0.5 ms pulse duration (PD) sonication given at 70% duty cycle, compared to the use of 1 and 2 ms PD, elicited more distinctive FEP peak features from the hemisphere ipsilateral to sonication. Although several participants reported hearing tones associated with FUS stimulation, the observed FEP were not likely to be confounded by the auditory sensation based on a separate measurement of auditory evoked potentials (AEP) to tonal stimulation (mimicking the same repetition frequency as the FUS stimulation). Off-line changes in resting-state functional connectivity (FC) associated with thalamic stimulation revealed that the FUS stimulation enhanced connectivity in a network of sensorimotor and sensory integration areas, which lasted for at least more than an hour. Clinical neurological evaluations, EEG, and neuroanatomical MRI did not reveal any adverse or unintended effects of sonication, attesting its safety. These results suggest that FUS stimulation may induce long-term neuroplasticity in humans, indicating its neurotherapeutic potential for various neurological and neuropsychiatric conditions.
Collapse
Affiliation(s)
- Hyun-Chul Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Daniel S Weisholtz
- Department of Neurology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
11
|
Brinker ST, Yoon K, Benveniste H. Global sonication of the human intracranial space via a jumbo planar transducer. ULTRASONICS 2023; 134:107062. [PMID: 37343366 DOI: 10.1016/j.ultras.2023.107062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 05/25/2023] [Accepted: 05/30/2023] [Indexed: 06/23/2023]
Abstract
Contrary to conditioning a Focused Ultrasound (FUS) beam to sonicate a localized region of the human brain, the goal of this investigation was to explore the prospect of distributing homogeneous ultrasound energy over the entire brain space with a large cranium-wide ultrasound beam. Recent ultrasound preclincal studies utilizing large or whole brain stimulation regions create a demand for expanding the treatment envelope of transcranial pulsed-low intensity ultrasound towards Global Brain Sonication (GBS) for potential human investigation. Here, we conduct ultrasound field characterizations when transmitting pulsed ultrasound through human skull specimens using a 1-3 piezocomposite planar transducer operating at 464 kHz with an active single-element surface of 30 × 30 cm. Through computational simulation and hydrophone scanning methodology, ultrasound wave behavior and dose homogeneity in the brain space were evaluated under various trajectories of sonication using the planar transducer. Clinically relevant pulse parameters used for transcranial therapeutic ultrasound applications were used in the experiments. Simulations and empirical testing revealed that dose homogeneity and acoustic intensity over the brain space are influenced by sonication trajectory, skull lens effects, and acoustic wave reflections. The transducer can emit a spatial peak pulse average intensity of 4.03 W/cm2 (0.24 MPa) measured in the free-field at 464 kHz with electrical power of 1 kW. The simulation showed that approximately 99 % of the cranial volume was exposed with <30 % of the maximum external acoustic intensity being transmitted into the skull. The transmission loss across all sonication trajectories is similar to previously reported FUS studies. A marker for GBS dose homogeneity is introduced to score the ultrasound pressure field uniformity in the intracranial space. Results of this study identify the initial challenges of exposing the entire human brain space with ultrasound using a large cranium-wide sonication beam intended for global brain therapeutic modulation.
Collapse
Affiliation(s)
- Spencer T Brinker
- Department of Anesthesiology, Yale School of Medicine, New Haven, CT, USA.
| | - Kyungho Yoon
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul, South Korea
| | - Helene Benveniste
- Department of Anesthesiology, Yale School of Medicine, New Haven, CT, USA
| |
Collapse
|
12
|
Shin M, Peng Z, Kim HJ, Yoo SS, Yoon K. Multivariable-incorporating super-resolution residual network for transcranial focused ultrasound simulation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 237:107591. [PMID: 37182263 DOI: 10.1016/j.cmpb.2023.107591] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/02/2023] [Accepted: 05/06/2023] [Indexed: 05/16/2023]
Abstract
BACKGROUND AND OBJECTIVE Transcranial focused ultrasound (tFUS) has emerged as a new non-invasive brain stimulation (NIBS) modality, with its exquisite ability to reach deep brain areas at a high spatial resolution. Accurate placement of an acoustic focus to a target region of the brain is crucial during tFUS treatment; however, the distortion of acoustic wave propagation through the intact skull casts challenges. High-resolution numerical simulation allows for monitoring of the acoustic pressure field in the cranium but also demands extensive computational loads. In this study, we adopt a super-resolution residual network technique based on a deep convolution to enhance the prediction quality of the FUS acoustic pressure field in the targeted brain regions. METHODS The training dataset was acquired by numerical simulations performed at low-(1.0 mm) and high-resolutions (0.5mm) on three ex vivo human calvariae. Five different super-resolution (SR) network models were trained by using a multivariable dataset in 3D, which incorporated information on the acoustic pressure field, wave velocity, and localized skull computed tomography (CT) images. RESULTS The accuracy of 80.87±4.50% in predicting the focal volume with a substantial improvement of 86.91% in computational cost compared to the conventional high-resolution numerical simulation was achieved. The results suggest that the method can greatly reduce the simulation time without sacrificing accuracy and improve the accuracy further with the use of additional inputs. CONCLUSIONS In this research, we developed multivariable-incorporating SR neural networks for transcranial focused ultrasound simulation. Our super-resolution technique may contribute to promoting the safety and efficacy of tFUS-mediated NIBS by providing on-site feedback information on the intracranial pressure field to the operator.
Collapse
Affiliation(s)
- Minwoo Shin
- School of Mathematics and Computing (Computational Science and Engineering), Seoul 03722, Republic of Korea
| | - Zhuogang Peng
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame 46556, IN, USA
| | - Hyo-Jin Kim
- School of Mathematics and Computing (Computational Science and Engineering), Seoul 03722, Republic of Korea
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston 02115, MA, USA
| | - Kyungho Yoon
- School of Mathematics and Computing (Computational Science and Engineering), Seoul 03722, Republic of Korea.
| |
Collapse
|
13
|
Chen M, Peng C, Wu H, Huang CC, Kim T, Traylor Z, Muller M, Chhatbar PY, Nam CS, Feng W, Jiang X. Numerical and experimental evaluation of low-intensity transcranial focused ultrasound wave propagation using human skulls for brain neuromodulation. Med Phys 2023; 50:38-49. [PMID: 36342303 PMCID: PMC10099743 DOI: 10.1002/mp.16090] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 10/20/2022] [Accepted: 10/21/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Low-intensity transcranial focused ultrasound (tFUS) has gained considerable attention as a promising noninvasive neuromodulatory technique for human brains. However, the complex morphology of the skull hinders scholars from precisely predicting the acoustic energy transmitted and the region of the brain impacted during the sonication. This is due to the fact that different ultrasound frequencies and skull morphology variations greatly affect wave propagation through the skull. PURPOSE Although the acoustic properties of human skull have been studied for tFUS applications, such as tumor ablation using a multielement phased array, there is no consensus about how to choose a single-element focused ultrasound (FUS) transducer with a suitable frequency for neuromodulation. There are interests in exploring the magnitude and dimension of tFUS beam through human parietal bone for modulating specific brain lobes. Herein, we aim to investigate the wave propagation of tFUS on human skulls to understand and address the concerns above. METHODS Both experimental measurements and numerical modeling were conducted to investigate the transmission efficiency and beam pattern of tFUS on five human skulls (C3 and C4 regions) using single-element FUS transducers with six different frequencies (150-1500 kHz). The degassed skull was placed in a water tank, and a calibrated hydrophone was utilized to measure acoustic pressure past it. The cranial computed tomography scan data of each skull were obtained to derive a high-resolution acoustic model (grid point spacing: 0.25 mm) in simulations. Meanwhile, we modified the power-law exponent of acoustic attenuation coefficient to validate numerical modeling and enabled it to be served as a prediction tool, based on the experimental measurements. RESULTS The transmission efficiency and -6 dB beamwidth were evaluated and compared for various frequencies. An exponential decrease in transmission efficiency and a logarithmic decrease of -6 dB beamwidth with an increase in ultrasound frequency were observed. It is found that a >750 kHz ultrasound leads to a relatively lower tFUS transmission efficiency (<5%), whereas a <350 kHz ultrasound contributes to a relatively broader beamwidth (>5 mm). Based on these observations, we further analyzed the dependence of tFUS wave propagation on FUS transducer aperture size. CONCLUSIONS We successfully studied tFUS wave propagation through human skulls at different frequencies experimentally and numerically. The findings have important implications to predict tFUS wave propagation for ultrasound neuromodulation in clinical applications, and guide researchers to develop advanced ultrasound transducers as neural interfaces.
Collapse
Affiliation(s)
- Mengyue Chen
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Chang Peng
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA.,School of Biomedical Engineering, ShanghaiTech University, Shanghai, China
| | - Huaiyu Wu
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Chih-Chung Huang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA.,Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Taewon Kim
- Department of Neurology, Duke University School of Medicine, Durham, North Carolina, USA
| | - Zachary Traylor
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Marie Muller
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Pratik Y Chhatbar
- Department of Neurology, Duke University School of Medicine, Durham, North Carolina, USA
| | - Chang S Nam
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, North Carolina, USA
| | - Wuwei Feng
- Department of Neurology, Duke University School of Medicine, Durham, North Carolina, USA
| | - Xiaoning Jiang
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
| |
Collapse
|
14
|
Kim HC, Lee W, Kowsari K, Weisholtz DS, Yoo SS. Effects of focused ultrasound pulse duration on stimulating cortical and subcortical motor circuits in awake sheep. PLoS One 2022; 17:e0278865. [PMID: 36512563 PMCID: PMC9746960 DOI: 10.1371/journal.pone.0278865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 11/26/2022] [Indexed: 12/15/2022] Open
Abstract
Low-intensity transcranial focused ultrasound (tFUS) offers new functional neuromodulation opportunities, enabling stimulation of cortical as well as deep brain areas with high spatial resolution. Brain stimulation of awake sheep, in the absence of the confounding effects of anesthesia on brain function, provides translational insight into potential human applications with safety information supplemented by histological analyses. We examined the effects of tFUS pulsing parameters, particularly regarding pulse durations (PDs), on stimulating the cortical motor area (M1) and its thalamic projection in unanesthetized, awake sheep (n = 8). A wearable tFUS headgear, custom-made for individual sheep, enabled experiments to be conducted without using anesthesia. FUS stimuli, each 200 ms long, were delivered to the M1 and the thalamus using three different PDs (0.5, 1, and 2 ms) with the pulse repetition frequency (PRF) adjusted to maintain a 70% duty cycle at a derated in situ spatial-peak temporal-average intensity (Ispta) of 3.6 W/cm2. Efferent electromyography (EMG) responses to stimulation were quantified from both hind limbs. Group-averaged EMG responses from each of the hind limbs across the experimental conditions revealed selective responses from the hind limb contralateral to sonication. The use of 0.5 and 1 ms PDs generated higher EMG signal amplitudes compared to those obtained using a 2 ms PD. Faster efferent response was also observed from thalamic stimulation than that from stimulating the M1. Post-sonication behavioral observation and histological assessment performed 24 h and 1 month after sonication were not indicative of any abnormalities. The results suggest the presence of pulsing scheme-dependent effects of tFUS on brain stimulation and attest its safety in awake large animals.
Collapse
Affiliation(s)
- Hyun-Chul Kim
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, United States of America
- Department of Artificial Intelligence, Kyungpook National University, Daegu, South Korea
| | - Wonhye Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, United States of America
| | - Kavin Kowsari
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, United States of America
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Daniel S. Weisholtz
- Department of Neurology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, United States of America
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
15
|
Park TY, Jeong JH, Chung YA, Yeo SH, Kim H. Application of subject-specific helmets for the study of human visuomotor behavior using transcranial focused ultrasound: a pilot study. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107127. [PMID: 36126434 DOI: 10.1016/j.cmpb.2022.107127] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Revised: 07/27/2022] [Accepted: 09/12/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND AND OBJECTIVE As a novel non-invasive human brain stimulation method, transcranial focused ultrasound (tFUS) is receiving growing attention due to its superior spatial specificity and depth penetrability. Since the focal point of tFUS needs to be fixated precisely to the target brain region during stimulation, a critical issue is to identify and maintain the accurate position and orientation of the tFUS transducer relative to the subject's head. This study aims to propose the entire framework of tFUS stimulation integrating the methods previously proposed by the authors for tFUS transducer configuration optimization and a subject-specific 3D-printed helmet, and to validate this complete setup in a human behavioral neuromodulation study. METHODS To find the optimal configuration of the tFUS transducer, a numerical method based on subject-specific tFUS beamlines simulation was used. Then, the subject-specific 3D-printed helmet has been applied to effectively secure the transducer at the estimated optimal configuration. To validate this tFUS framework, a common behavioral neuromodulation paradigm was chosen; the effect of the dorsolateral prefrontal cortex (DLPFC) stimulation on anti-saccade (AS) behavior. While human participants (n=2) were performing AS tasks, tFUS stimulations were randomly applied to the left DLPFC right after the fixation target disappeared. RESULTS The neuromodulation result strongly suggests that the cortical stimulation using the proposed tFUS setup is effective in significantly reducing the error rates of anti-saccades (about -10 %p for S1 and -16 %p for S2), whereas no significant effect was observed on their latencies. These observed behavioral effects are consistent with the previous results based on conventional brain stimulation or lesion studies. CONCLUSIONS The proposed subject-specific tFUS framework has been effectively used in human neuromodulation study. The result suggests that the tFUS stimulation targeted to the DLPFC can generate a neuromodulatory effect on AS behavior.
Collapse
Affiliation(s)
- Tae Young Park
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul, 02792, Republic of Korea
| | - Ji Hyeok Jeong
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea; Department of Brain and Cognitive Engineering, Korea University, Seoul, 136-713, Republic of Korea
| | - Yong An Chung
- Incheon St. Mary's Hospital, The Catholic University of Korea, Republic of Korea
| | - Sang Hoon Yeo
- School of Sport, Exercise & Rehabilitation Sciences, The University of Birmingham, Edgbaston, Birmingham, B15 2TT, United Kingdom.
| | - Hyungmin Kim
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul, 02792, Republic of Korea.
| |
Collapse
|
16
|
Yoo SS, Kim HC, Kim J, Kim E, Kowsari K, Van Reet J, Yoon K. Enhancement of cerebrospinal fluid tracer movement by the application of pulsed transcranial focused ultrasound. Sci Rep 2022; 12:12940. [PMID: 35902724 PMCID: PMC9334279 DOI: 10.1038/s41598-022-17314-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 07/25/2022] [Indexed: 11/10/2022] Open
Abstract
Efficient transport of solutes in the cerebrospinal fluid (CSF) plays a critical role in their clearance from the brain. Convective bulk flow of solutes in the CSF in the perivascular space (PVS) is considered one of the important mechanisms behind solute movement in the brain, before their ultimate drainage to the systemic lymphatic system. Acoustic pressure waves can impose radiation force on a medium in its path, inducing localized and directional fluidic flow, known as acoustic streaming. We transcranially applied low-intensity focused ultrasound (FUS) to rats that received an intracisternal injection of fluorescent CSF tracers (dextran and ovalbumin, having two different molecular weights-Mw). The sonication pulsing parameter was determined on the set that propelled the aqueous solution of toluidine blue O dye into a porous media (melamine foam) at the highest level of infiltration. Fluorescence imaging of the brain showed that application of FUS increased the uptake of ovalbumin at the sonicated plane, particularly around the ventricles, whereas the uptake of high-Mw dextran was unaffected. Numerical simulation showed that the effects of sonication were non-thermal. Sonication did not alter the animals' behavior or disrupt the blood-brain barrier (BBB) while yielding normal brain histology. The results suggest that FUS may serve as a new non-invasive means to promote interstitial CSF solute transport in a region-specific manner without disrupting the BBB, providing potential for enhanced clearance of waste products from the brain.
Collapse
Affiliation(s)
- Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA.
| | - Hyun-Chul Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
- Department of Artificial Intelligence, Kyungpook National University, Daegu, Republic of Korea
| | - Jaeho Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
- Department of Neurology, Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - Evgenii Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Kavin Kowsari
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Boston, MA, USA
| | - Jared Van Reet
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Kyungho Yoon
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
17
|
Chen H, Felix C, Folloni D, Verhagen L, Sallet J, Jerusalem A. Modelling transcranial ultrasound neuromodulation: an energy-based multiscale framework. Acta Biomater 2022; 151:317-332. [PMID: 35902037 DOI: 10.1016/j.actbio.2022.07.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 11/26/2022]
Abstract
Several animal and human studies have now established the potential of low intensity, low frequency transcranial ultrasound (TUS) for non-invasive neuromodulation. Paradoxically, the underlying mechanisms through which TUS neuromodulation operates are still unclear, and a consensus on the identification of optimal sonication parameters still remains elusive. One emerging hypothesis based on thermodynamical considerations attributes the acoustic-induced nerve activity alterations to the mechanical energy and/or entropy conversions occurring during TUS action. Here, we propose a multiscale modelling framework to examine the energy states of neuromodulation under TUS. First, macroscopic tissue-level acoustic simulations of the sonication of a whole monkey brain are conducted under different sonication protocols. For each one of them, mechanical loading conditions of the received waves in the anterior cingulate cortex region are recorded and exported into a microscopic cell-level 3D viscoelastic finite element model of neuronal axon embedded extracellular medium. Pulse-averaged elastically stored and viscously dissipated energy rate densities during axon deformation are finally computed under different sonication incident angles and are mapped against distinct combinations of sonication parameters of the TUS. The proposed multiscale framework allows for the analysis of vibrational patterns of the axons and its comparison against the spectrograms of stimulating ultrasound. The results are in agreement with literature data on neuromodulation, demonstrating the potential of this framework to identify optimised acoustic parameters in TUS neuromodulation. The proposed approach is finally discussed in the context of multiphysics energetic considerations, argued here to be a promising avenue towards a scalable framework for TUS in silico predictions. STATEMENT OF SIGNIFICANCE: Low-intensity transcranial ultrasound (TUS) is poised to become a leading neuromodulation technique for the treatment of neurological disorders. Paradoxically, how it operates at the cellular scale remains unknown, hampering progress in personalised treatment. To this end, models of the multiphysics of neurons able to upscale results to the organ scale are required. We propose here to achieve this by considering an axon submitted to an ultrasound wave extracted from a simulation at the organ scale. Doing so, information pertaining to both stored and dissipated axonal energies can be extracted for a given head/brain morphology. This two-scale multiphysics energetic approach is a promising scalable framework for in silico predictions in the context of personalised TUS treatment.
Collapse
Affiliation(s)
- Haoyu Chen
- Department of Engineering Science, University of Oxford, Oxford, UK
| | - Ciara Felix
- Department of Engineering Science, University of Oxford, Oxford, UK
| | - Davide Folloni
- Wellcome Centre for Integrative Neuroimaging (WIN), Department of Experimental Psychology, University of Oxford, Oxford, UK; Department of Neuroscience and Friedman Brain Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Lennart Verhagen
- Wellcome Centre for Integrative Neuroimaging (WIN), Department of Experimental Psychology, University of Oxford, Oxford, UK; Donders Institute, Radboud University, Nijmegen, Netherlands
| | - Jérôme Sallet
- Wellcome Centre for Integrative Neuroimaging (WIN), Department of Experimental Psychology, University of Oxford, Oxford, UK; Inserm, Stem Cell and Brain Research Institute, Université Lyon 1, Bron, France
| | - Antoine Jerusalem
- Department of Engineering Science, University of Oxford, Oxford, UK.
| |
Collapse
|
18
|
Slezak C, Flatscher J, Slezak P. A Comparative Feasibility Study for Transcranial Extracorporeal Shock Wave Therapy. Biomedicines 2022; 10:biomedicines10061457. [PMID: 35740477 PMCID: PMC9219950 DOI: 10.3390/biomedicines10061457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 06/05/2022] [Accepted: 06/11/2022] [Indexed: 12/03/2022] Open
Abstract
The potential beneficial regenerative and stimulatory extracorporeal shock wave therapy (ESWT) applications to the central nervous system have garnered interest in recent years. Treatment zones for these indications are acoustically shielded by bones, which heavily impact generated sound fields. We present the results of high-resolution tissue-realistic simulations, comparing the viability of different ESWT applicators in their use for transcranial applications. The performances of electrohydraulic, electromagnetic, and piezoelectric transducers for key reflector geometries are compared. Based on density information obtained from CT imaging of the head, we utilized the non-linear wave propagation toolset Matlab k-Wave to obtain spatial therapeutic sound field geometries and waveforms. In order to understand the reliability of results on the appropriate modeling of the skull, three different bone attenuation models were compared. We find that all currently clinically ESWT applicator technologies show significant retention of peak pressures and energies past the bone barrier. Electromagnetic transducers maintain a significantly higher energy flux density compared to other technologies while low focusing strength piezoelectric applicators have the weakest transmissions. Attenuation estimates provide insights into sound field degradation and energy losses, indicating that effective transcranial therapies can readily be attained with current applicators. Furthermore, the presented approach will allow for future targeted in silico development and the design of applicators and therapy plans to ultimately improve therapeutic outcomes.
Collapse
Affiliation(s)
- Cyrill Slezak
- Department of Physics, Utah Valley University, Orem, UT 84058, USA;
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Center, 1200 Vienna, Austria;
- Austrian Cluster for Tissue Regeneration, 1200 Vienna, Austria
| | - Jonas Flatscher
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Center, 1200 Vienna, Austria;
| | - Paul Slezak
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Center, 1200 Vienna, Austria;
- Austrian Cluster for Tissue Regeneration, 1200 Vienna, Austria
- Correspondence:
| |
Collapse
|
19
|
Brinker ST, Balchandani P, Seifert AC, Kim HJ, Yoon K. Feasibility of Upper Cranial Nerve Sonication in Human Application via Neuronavigated Single-Element Pulsed Focused Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1045-1057. [PMID: 35341621 DOI: 10.1016/j.ultrasmedbio.2022.01.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 01/27/2022] [Accepted: 01/31/2022] [Indexed: 06/14/2023]
Abstract
Sonicating deep brain regions with pulsed focused ultrasound using magnetic resonance imaging-guided neuronavigation single-element piezoelectric transducers is a new area of exploration for neuromodulation. Upper cranial nerves such as the trigeminal nerve and other nerves responsible for sensory/motor functions in the head may be potential targets for ultrasound pain therapy. The location of upper cranial nerves close to the skull base poses additional challenges when compared with conventional cortical or middle brain targets. In the work described here, a series of computational and empirical testing methods using human skull specimens were conducted to assess the feasibility of sonicating the trigeminal pathway near the sphenoid bone region. The results indicate a transducer with a focal length of 120 mm and diameter of 85 mm (350 kHz) can deliver sonication to upper cranial nerve regions with spatial accuracy comparable to that of focused ultrasound brain targets used in previous human studies. Temperature measurements in cortical bone and in the skull base with embedded thermocouples yield evidence of minimal bone heating. Conventional pulse parameters were found to cause reverberation interference patterns near the cranial floor; therefore, changes in pulse cycles and pulse repetition frequency were examined for reducing standing waves. Limitations and considerations for conducting ultradeep focal targeting in human applications are discussed.
Collapse
Affiliation(s)
- Spencer T Brinker
- Department of Anesthesiology, Yale School of Medicine, New Haven, Connecticut, USA.
| | - Priti Balchandani
- BioMedical Engineering and Imaging Institute, Departments of Diagnostic, Molecular and Interventional Radiology, Neuroscience and Psychiatry, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Alan C Seifert
- Biomedical Engineering and Imaging Institute, Department of Diagnostic, Molecular and Interventional Radiology, and Graduate School of Biomedical Sciences, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Hyo-Jin Kim
- Center for Healthcare Robotics, Korea Institute of Science and Technology, Seoul, South Korea
| | - Kyungho Yoon
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul, South Korea
| |
Collapse
|
20
|
Park TY, Kim HJ, Park SH, Chang WS, Kim H, Yoon K. Differential evolution method to find optimal location of a single-element transducer for transcranial focused ultrasound therapy. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 219:106777. [PMID: 35397411 DOI: 10.1016/j.cmpb.2022.106777] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 03/14/2022] [Accepted: 03/24/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Focused ultrasound (FUS) has been receiving growing attention as a noninvasive brain stimulation tool because of its superior spatial specificity and depth penetrability. However, the large mismatch of acoustic properties between the skull and water can disrupt and shift the acoustic focus in the brain. In this paper, we present a numerical method to find the optimal location of a single-element FUS transducer, which creates focus on the target region. METHODS The score function, representing the superposition of acoustic waves according to the relative phase difference and transmissibility, was defined based on time-reversal invariance of acoustic waves and depending on the spatial location of the transducer. The optimal location of the transducer was then determined using a differential evolution algorithm. To assess the proposed method, we conducted a forward simulation and compared the resulting focal location to the desired target point. We also performed experimental validation by measuring the acoustic pressure field through an ex vivo human skull in a water tank. RESULTS The numerical results indicated that the score function had a positive proportional relationship with the acoustic pressure at the target. Moreover, for the optimized transducer location, both the numerical and experimental results showed that the normalized acoustic pressure at the target was higher than 0.9. CONCLUSIONS In this study, we developed an optimization method to place a single-element transducer that effectively transmits acoustic energy to the targeted region in the brain. Our numerical and experimental results demonstrate that the proposed method can provide an optimal transducer location for safe and efficient FUS treatment.
Collapse
Affiliation(s)
- Tae Young Park
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul 02792, Republic of Korea.
| | - Hyo-Jin Kim
- Center for Healthcare Robotics, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
| | - So Hui Park
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul 04527, Republic of Korea
| | - Won Seok Chang
- Department of Neurosurgery, Brain Research Institute, Yonsei University College of Medicine, Seoul 04527, Republic of Korea
| | - Hyungmin Kim
- Bionics Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea; Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul 02792, Republic of Korea.
| | - Kyungho Yoon
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul 03722, Republic of Korea.
| |
Collapse
|
21
|
Kim HC, Lee W, Kunes J, Yoon K, Lee JE, Foley L, Kowsari K, Yoo SS. Transcranial focused ultrasound modulates cortical and thalamic motor activity in awake sheep. Sci Rep 2021; 11:19274. [PMID: 34588588 PMCID: PMC8481295 DOI: 10.1038/s41598-021-98920-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 09/08/2021] [Indexed: 11/09/2022] Open
Abstract
Transcranial application of pulsed low-intensity focused ultrasound (FUS) modulates the excitability of region-specific brain areas, and anesthetic confounders on brain activity warrant the evaluation of the technique in awake animals. We examined the neuromodulatory effects of FUS in unanesthetized sheep by developing a custom-fit headgear capable of reproducibly placing an acoustic focus on the unilateral motor cortex (M1) and corresponding thalamic area. The efferent responses to sonication, based on the acoustic parameters previously identified in anesthetized sheep, were measured using electromyography (EMG) from both hind limbs across three experimental conditions: on-target sonication, off-target sonication, and without sonication. Excitatory sonication yielded greater amplitude of EMG signals obtained from the hind limb contralateral to sonication than that from the ipsilateral limb. Spurious appearance of motion-related EMG signals limited the amount of analyzed data (~ 10% selection of acquired data) during excitatory sonication, and the averaged EMG response rates elicited by the M1 and thalamic stimulations were 7.5 ± 1.4% and 6.7 ± 1.5%, respectively. Suppressive sonication, while sheep walked on the treadmill, temporarily reduced the EMG amplitude from the limb contralateral to sonication. No significant change was found in the EMG amplitudes during the off-target sonication. Behavioral observation throughout the study and histological analysis showed no sign of brain tissue damage caused by the acoustic stimulation. Marginal response rates observed during excitatory sonication call for technical refinement to reduce motion artifacts during EMG acquisitions as well as acoustic aberration correction schemes to improve spatial accuracy of sonication. Yet, our results indicate that low-intensity FUS modulated the excitability of regional brain tissues reversibly and safely in awake sheep, supporting its potential in theragnostic applications.
Collapse
Affiliation(s)
- Hyun-Chul Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Jennifer Kunes
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Kyungho Yoon
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Ji Eun Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Lori Foley
- Translational Discovery Laboratory, Brigham and Women's Hospital, Boston, MA, USA
| | - Kavin Kowsari
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA.
| |
Collapse
|
22
|
Koh H, Park TY, Chung YA, Lee JH, Kim H. Acoustic simulation for transcranial focused ultrasound using GAN-based synthetic CT. IEEE J Biomed Health Inform 2021; 26:161-171. [PMID: 34388098 DOI: 10.1109/jbhi.2021.3103387] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Transcranial focused ultrasound (tFUS) is a promising non-invasive technique for treating neurological and psychiatric disorders. One of the challenges for tFUS is the disruption of wave propagation through the skull. Consequently, despite the risks associated with exposure to ionizing radiation, computed tomography (CT) is required to estimate the acoustic transmission through the skull. This study aims to generate synthetic CT (sCT) from T1-weighted magnetic resonance imaging (MRI) and investigate its applicability to tFUS acoustic simulation. We trained a 3D conditional generative adversarial network (3D-cGAN) with 15 subjects. We then assessed image quality with 15 test subjects: mean absolute error (MAE) = 85.72± 9.50 HU (head) and 280.25±24.02 HU (skull), dice coefficient similarity (DSC) = 0.88±0.02 (skull). In terms of skull density ratio (SDR) and skull thickness (ST), no significant difference was found between sCT and real CT (rCT). When the acoustic simulation results of rCT and sCT were compared, the intracranial peak acoustic pressure ratio was found to be less than 4%, and the distance between focal points less than 1 mm.
Collapse
|
23
|
Montanaro H, Pasquinelli C, Lee HJ, Kim H, Siebner HR, Kuster N, Thielscher A, Neufeld E. The impact of CT image parameters and skull heterogeneity modeling on the accuracy of transcranial focused ultrasound simulations. J Neural Eng 2021; 18. [PMID: 33836508 DOI: 10.1088/1741-2552/abf68d] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 04/09/2021] [Indexed: 11/12/2022]
Abstract
Objective. Low-intensity transcranial ultrasound stimulation (TUS) is a promising non-invasive brain stimulation (NIBS) technique. TUS can reach deeper areas and target smaller regions in the brain than other NIBS techniques, but its application in humans is hampered by the lack of a straightforward and reliable procedure to predict the induced ultrasound exposure. Here, we examined how skull modeling affects computer simulations of TUS.Approach. We characterized the ultrasonic beam after transmission through a sheep skull with a hydrophone and performed computed tomography (CT) image-based simulations of the experimental setup. To study the skull model's impact, we varied: CT acquisition parameters (tube voltage, dose, filter sharpness), image interpolation, segmentation parameters, acoustic property maps (speed-of-sound, density, attenuation), and transducer-position mismatches. We compared the impact of modeling parameter changes on model predictions and on measurement agreement. Spatial-peak intensity and location, total power, and the Gamma metric (a measure for distribution differences) were used as quantitative criteria. Modeling-based sensitivity analysis was also performed for two human head models.Main results. Sheep skull attenuation assignment and transducer positioning had the most important impact on spatial peak intensity (overestimation up to 300%, respectively 30%), followed by filter sharpness and tube voltage (up to 20%), requiring calibration of the mapping functions. Positioning and skull-heterogeneity-structure strongly affected the intensity distribution (gamma tolerances exceeded in>80%, respectively>150%, of the focus-volume in water), necessitating image-based personalized modeling. Simulation results in human models consistently demonstrate a high sensitivity to the skull-heterogeneity model, attenuation tuning, and transducer shifts, the magnitude of which depends on the underlying skull structure complexity.Significance. Our study reveals the importance of properly modeling the skull-heterogeneity and its structure and of accurately reproducing the transducer position. The results raise red flags when translating modeling approaches among clinical sites without proper standardization and/or recalibration of the imaging and modeling parameters.
Collapse
Affiliation(s)
- Hazael Montanaro
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.,Department of Information Technology and Electrical Engineering , Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.,Laboratory for Acoustics/Noise Control, EMPA, Swiss Federal Laboratories for Materials Science and Technology, Dubendorf, Switzerland.,The authors contributed equally to the work
| | - Cristina Pasquinelli
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital - Amager and Hvidovre, Copenhagen, Denmark.,Center for Magnetic Resonance, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark.,The authors contributed equally to the work
| | - Hyunjoo J Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Hyunggug Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Hartwig R Siebner
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital - Amager and Hvidovre, Copenhagen, Denmark.,Department of Neurology , Copenhagen University Hospital Bispebjerg, Copenhagen, Denmark.,Institute of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen , Copenhagen, Denmark
| | - Niels Kuster
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.,Department of Information Technology and Electrical Engineering , Swiss Federal Institute of Technology (ETH), Zurich, Switzerland
| | - Axel Thielscher
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital - Amager and Hvidovre, Copenhagen, Denmark.,Center for Magnetic Resonance, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Esra Neufeld
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.,Department of Information Technology and Electrical Engineering , Swiss Federal Institute of Technology (ETH), Zurich, Switzerland
| |
Collapse
|
24
|
Lee W, Weisholtz DS, Strangman GE, Yoo SS. Safety Review and Perspectives of Transcranial Focused Ultrasound Brain Stimulation. BRAIN & NEUROREHABILITATION 2021; 14:e4. [PMID: 36742103 PMCID: PMC9879416 DOI: 10.12786/bn.2021.14.e4] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Revised: 02/17/2021] [Accepted: 03/04/2021] [Indexed: 11/08/2022] Open
Abstract
Ultrasound is an important theragnostic modality in modern medicine. Technical advancement of both acoustic focusing and transcranial delivery have enabled administration of ultrasound waves to localized brain areas with few millimeters of spatial specificity and penetration depth sufficient to reach the thalamus. Transcranial focused ultrasound (tFUS) given at a low acoustic intensity has been shown to increase or suppress the excitability of region-specific brain areas. The neuromodulatory effects can outlast the sonication, suggesting the possibility of inducing neural plasticity needed for neurorehabilitation. Increasing numbers of studies have shown the efficacy and excellent safety profile of the technique, yet comparisons among the safety-related parameters have not been compiled. This review aims to provide safety information and perspectives of tFUS brain stimulation. First, the acoustic parameters most relevant to thermal/mechanical tissue damage are discussed along with regulated parameters for existing ultrasound therapies/diagnostic imaging. Subsequently, the parameters used in studies of large animals, non-human primates, and humans are surveyed and summarized in terms of the acoustic intensity and the mechanical index. The pulse-mode operation and the use of low ultrasound frequency for tFUS-mediated brain stimulation warrant the establishment of new safety guidelines/recommendations for the use of the technique among healthy volunteers, with additional cautionary requirements for its clinical translation.
Collapse
Affiliation(s)
- Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Daniel S. Weisholtz
- Department of Neurology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Gary E. Strangman
- Neural Systems Group, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, USA
- Center for Space Medicine, Baylor College of Medicine, Houston, TX, USA
- Translational Research Institute, Houston, TX, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
25
|
Estrada H, Ozbek A, Robin J, Shoham S, Razansky D. Spherical Array System for High-Precision Transcranial Ultrasound Stimulation and Optoacoustic Imaging in Rodents. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:107-115. [PMID: 32406833 PMCID: PMC7952015 DOI: 10.1109/tuffc.2020.2994877] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Ultrasound can be delivered transcranially to ablate brain tissue, open the blood-brain barrier, or affect neural activity. Transcranial focused ultrasound in small rodents is typically done with low-frequency single-element transducers, which results in unspecific targeting and impedes the concurrent use of fast neuroimaging methods. In this article, we devised a wide-angle spherical array bidirectional interface for high-resolution parallelized optoacoustic imaging and transcranial ultrasound (POTUS) delivery in the same target regions. The system operates between 3 and 9 MHz, allowing to generate and steer focal spots with widths down to [Formula: see text] across a field of view covering the entire mouse brain, while the same array is used to capture high-resolution 3-D optoacoustic data in real time. We showcase the system's versatile beam-forming capacities as well as volumetric optoacoustic imaging capabilities and discuss its potential to noninvasively monitor brain activity and various effects of ultrasound emission.
Collapse
|
26
|
Mohammadi L, Behnam H, Tavakkoli J, Avanaki K. Skull acoustic aberration correction in photoacoustic microscopy using a vector space similarity model: a proof-of-concept simulation study. BIOMEDICAL OPTICS EXPRESS 2020; 11:5542-5556. [PMID: 33149969 PMCID: PMC7587255 DOI: 10.1364/boe.402027] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 08/30/2020] [Accepted: 09/07/2020] [Indexed: 05/18/2023]
Abstract
Skull bone represents a highly acoustical impedance mismatch and a dispersive barrier for the propagation of acoustic waves. Skull distorts the amplitude and phase information of the received waves at different frequencies in a transcranial brain imaging. We study a novel algorithm based on vector space similarity model for the compensation of the skull-induced distortions in transcranial photoacoustic microscopy. The results of the algorithm tested on a simplified numerical skull phantom, demonstrate a fully recovered vasculature with the recovery rate of 91.9%.
Collapse
Affiliation(s)
- Leila Mohammadi
- Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Hamid Behnam
- Department of Biomedical Engineering, Iran University of Science and Technology, Tehran 1684613114, Iran
| | - Jahan Tavakkoli
- Department of Physics, Ryerson University, Toronto, ON M5B 2K3, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Center for Biomedical Science, St. Michael’s Hospital, Toronto, ON M5B 1W8, Canada
| | - Kamran Avanaki
- Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA
- Department of Dermatology, University of Illinois at Chicago, Chicago, IL 60607, USA
| |
Collapse
|
27
|
Xu L, Lee W, Rotenberg A, Böhlke M, Yoon K, Yoo SS. Localized Disruption of Blood Albumin-Phenytoin Binding Using Transcranial Focused Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1986-1997. [PMID: 32402673 DOI: 10.1016/j.ultrasmedbio.2020.04.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 04/02/2020] [Accepted: 04/10/2020] [Indexed: 06/11/2023]
Abstract
Plasma protein binding (PPB) plays an important role in drug pharmacokinetics, particularly for central nervous system drugs, as PPB affects the blood concentration of unbound drug available to cross the blood-brain barrier (BBB). We report the non-invasive, spatially specific disruption of PPB to phenytoin, an anti-epileptic drug with high affinity to albumin, using 250-kHz focused ultrasound (FUS) delivered in a pulsed manner (55-ms tone burst duration, 4-Hz pulse repetitions). Equilibrium dialysis performed on sonicated phosphate-buffered saline solution containing phenytoin and bovine serum albumin revealed a 27.7% elevation in the unbound phenytoin concentration compared with an unsonicated control. Sonication of a unilateral brain hemisphere in rats (n = 10) after intraperitoneal phenytoin injection revealed increased parenchymal phenytoin uptake compared with the unsonicated hemisphere, without evidence of temperature change or BBB disruption. These findings illustrate the use of FUS as a novel technique for spatially selective disruption of PPB, which may be applied to a wide range of drug-plasma protein interactions.
Collapse
Affiliation(s)
- Linda Xu
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Alexander Rotenberg
- Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Mark Böhlke
- Massachusetts College of Pharmacy and Health Sciences University, Boston, Massachusetts, USA
| | - Kyungho Yoon
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| |
Collapse
|
28
|
Brinker ST, Preiswerk F, White PJ, Mariano TY, McDannold NJ, Bubrick EJ. Focused Ultrasound Platform for Investigating Therapeutic Neuromodulation Across the Human Hippocampus. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1270-1274. [PMID: 32088061 PMCID: PMC7239323 DOI: 10.1016/j.ultrasmedbio.2020.01.007] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 01/03/2020] [Accepted: 01/13/2020] [Indexed: 05/25/2023]
Abstract
Pulsed low-intensity focused ultrasound (PLIFUS) has shown promise in inducing neuromodulation in several animal and human studies. Therefore, it is of clinical interest to develop experimental platforms to test repetitive PLIFUS as a therapeutic modality in humans with neurologic disorders. In the study described here, our aim was to develop a laboratory-built experimental device platform intended to deliver repetitive PLIFUS across the hippocampus in seizure onset zones of patients with drug-resistant temporal lobe epilepsy. The system uses neuronavigation targeting over multiple therapeutic sessions. PLIFUS (548 kHz) was emitted across multiple hippocampal targets in a human subject with temporal lobe epilepsy using a mechanically steered piezoelectric transducer. Stimulation was delivered up to 2.25 W/cm2 spatial peak temporal average intensity (free-field equivalent), with 36%-50% duty cycle, 500-ms sonications and 7-s inter-stimulation intervals lasting 140 s per target and repeated for multiple sessions. A first-in-human PLIFUS course of treatment was successfully delivered using the device platform with no adverse events.
Collapse
Affiliation(s)
- Spencer T Brinker
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Frank Preiswerk
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Phillip J White
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA; Department of Physics, Simmons College, Boston, Massachusetts, USA
| | - Timothy Y Mariano
- Center for Neurorestoration and Neurotechnology, Providence Veterans Affairs Medical Center, Providence, Rhode Island, USA; Butler Hospital, Providence, Rhode Island, USA; Department of Psychiatry, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Nathan J McDannold
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | - Ellen J Bubrick
- Department of Neurology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| |
Collapse
|
29
|
Yoon K, Lee W, Lee JE, Xu L, Croce P, Foley L, Yoo SS. Effects of sonication parameters on transcranial focused ultrasound brain stimulation in an ovine model. PLoS One 2019; 14:e0224311. [PMID: 31648261 PMCID: PMC6812789 DOI: 10.1371/journal.pone.0224311] [Citation(s) in RCA: 75] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 10/10/2019] [Indexed: 01/01/2023] Open
Abstract
Low-intensity focused ultrasound (FUS) has significant potential as a non-invasive brain stimulation modality and novel technique for functional brain mapping, particularly with its advantage of greater spatial selectivity and depth penetration compared to existing non-invasive brain stimulation techniques. As previous studies, primarily carried out in small animals, have demonstrated that sonication parameters affect the stimulation efficiency, further investigation in large animals is necessary to translate this technique into clinical practice. In the present study, we examined the effects of sonication parameters on the transient modification of excitability of cortical and thalamic areas in an ovine model. Guided by anatomical and functional neuroimaging data specific to each animal, 250 kHz FUS was transcranially applied to the primary sensorimotor area associated with the right hind limb and its thalamic projection in sheep (n = 10) across multiple sessions using various combinations of sonication parameters. The degree of effect from FUS was assessed through electrophysiological responses, through analysis of electromyogram and electroencephalographic somatosensory evoked potentials for evaluation of excitatory and suppressive effects, respectively. We found that the modulatory effects were transient and reversible, with specific sonication parameters outperforming others in modulating regional brain activity. Magnetic resonance imaging and histological analysis conducted at different time points after the final sonication session, as well as behavioral observations, showed that repeated exposure to FUS did not damage the underlying brain tissue. Our results suggest that FUS-mediated, non-invasive, region-specific bimodal neuromodulation can be safely achieved in an ovine model, indicating its potential for translation into human studies.
Collapse
Affiliation(s)
- Kyungho Yoon
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Wonhye Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Ji Eun Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Linda Xu
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Phillip Croce
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Lori Foley
- Translational Discovery Laboratory, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
30
|
Park TY, Pahk KJ, Kim H. Method to optimize the placement of a single-element transducer for transcranial focused ultrasound. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 179:104982. [PMID: 31443869 DOI: 10.1016/j.cmpb.2019.104982] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Revised: 06/25/2019] [Accepted: 07/09/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE Transcranial focused ultrasound (tFUS) is a promising neuromodulation technique because of its non-invasiveness and high spatial resolution (within millimeter scale). However, the presence of the skull can lead to disrupting and shifting the acoustic focus in the brain. In this study, we propose a computationally efficient way to determine the optimal position of a single-element focused ultrasound transducer which can effectively deliver acoustic energy to the brain target. We hypothesized that the placement of a single element transducer with the lowest average reflection coefficient would be the optimal position. METHODS The reflection coefficient is defined by the ratio of the amplitude of the reflected wave to the incident wave. To calculate the reflection coefficient, we assumed ultrasound waves as straight lines (beam lines). At each beam line, the reflection coefficient was calculated from the incidence angle at the skull interface (outer/inner skull surfaces). The average reflection coefficient (ARC) was calculated at each possible placement of the transducer using a custom-built software. For comparison purposes, acoustic simulations (k-Wave MATLAB toolbox) which numerically solved the linear wave equation were performed with the same transducer positions used in the ARC calculation. In addition, the experimental validation of our proposed method was also performed by measuring acoustic wave propagation through the calvaria skull phantom in water. The accuracy of our method was defined as the distance between the two optimal transducer placements which were determined from the acoustic simulations and from the ARC method. RESULT Simulated acoustic pressure distribution corresponding to each ARC showed an inverse relationship with peak acoustic pressures produced in the brain. In comparison to the acoustic simulations, the accuracy of our method was 5.07 ± 4.27 mm when targeting the cortical region in the brain. The computing time of ARC calculations were 0.08% of the time required for acoustic pressure simulations. CONCLUSION We calculated the ARC to find the optimal position of the tFUS transducer used in the present study. The optimal placement of the transducer was found when the ARC was the lowest. Our numerical and experimental results showed that the proposed ARC method can effectively be used to find the optimal position of a single-element tFUS transducer for targeting the cortex region of the brain in a computationally inexpensive way.
Collapse
Affiliation(s)
- Tae Young Park
- Center for Bionics, Biomedical Research Institute, Korea Institute Science and Technology (KIST), 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea; Division of Bio-Medical Science & Technology, KIST School, Korea University of Science and Technology, 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea
| | - Ki Joo Pahk
- Center for Bionics, Biomedical Research Institute, Korea Institute Science and Technology (KIST), 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea
| | - Hyungmin Kim
- Center for Bionics, Biomedical Research Institute, Korea Institute Science and Technology (KIST), 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea; Division of Bio-Medical Science & Technology, KIST School, Korea University of Science and Technology, 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea.
| |
Collapse
|
31
|
Yoon K, Lee W, Chen E, Lee JE, Croce P, Cammalleri A, Foley L, Tsao AL, Yoo SS. Localized Blood-Brain Barrier Opening in Ovine Model Using Image-Guided Transcranial Focused Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2391-2404. [PMID: 31217090 PMCID: PMC6693666 DOI: 10.1016/j.ultrasmedbio.2019.05.023] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 05/13/2019] [Accepted: 05/21/2019] [Indexed: 05/03/2023]
Abstract
Transcranial application of focused ultrasound (FUS) combined with vascular introduction of microbubble contrast agents (MBs) has emerged as a non-invasive technique that can temporarily create a localized opening in the blood-brain barrier (BBB). Under image-guidance, we administered FUS to sheep brain after intravenous injection of microbubbles. BBB opening was confirmed by performing dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to detect the extravasated gadolinium-based magnetic resonance contrast agents. Through pharmacokinetic analysis as well as independent component analysis of the DCE-MRI data, we observed localized enhancement in BBB permeability at the area that subjected to acoustic pressure of 0.48 MPa (mechanical index = 0.96). On the other hand, application of a higher pressure at 0.58 MPa resulted in localized, minor cerebral hemorrhage. No animals exhibited abnormal behavior during the post-FUS survival periods up to 2 mo. Our data suggest that monitoring for excessive BBB disruption is important for safe translation of the method to humans.
Collapse
Affiliation(s)
- Kyungho Yoon
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Emily Chen
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Ji Eun Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Phillip Croce
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Amanda Cammalleri
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Lori Foley
- Translational Discovery Laboratory, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Allison L Tsao
- Translational Discovery Laboratory, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA; Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| |
Collapse
|
32
|
Brinker ST, Preiswerk F, McDannold NJ, Parker KL, Mariano TY. Virtual Brain Projection for Evaluating Trans-skull Beam Behavior of Transcranial Ultrasound Devices. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1850-1856. [PMID: 31060860 PMCID: PMC6827342 DOI: 10.1016/j.ultrasmedbio.2019.03.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 03/07/2019] [Accepted: 03/11/2019] [Indexed: 05/31/2023]
Abstract
Focused ultrasound single-element piezoelectric transducers constitute a promising method to deliver ultrasound to the brain in low-intensity applications, but are subject to defocusing and high attenuation because of transmission through the skull. Here, a novel virtual brain projection method is used to superimpose a magnetic resonance image of the brain in ex vivo human skulls to provide targets during trans-skull focused ultrasound single-element piezoelectric transducer pressure field mapping. Positions of the transducer, skull and hydrophone are tracked in real time using a stereoscopic navigation camera and 3-D Slicer software. Virtual targets of the left dorsolateral prefrontal cortex, left hippocampus and cerebellar vermis were chosen to illustrate the method's flexibility in evaluating focal-zone beam distortion and attenuation. The regions are of interest as non-invasive brain stimulation targets in the treatment of neuropsychiatric disorders via repeated ultrasound exposure. The technical approach can facilitate the assessment of transcranial ultrasound device operator positioning reliability, intracranial beam behavior and computational model validation.
Collapse
Affiliation(s)
- Spencer T Brinker
- Department of Radiology, Brigham & Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | - Frank Preiswerk
- Department of Radiology, Brigham & Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Nathan J McDannold
- Department of Radiology, Brigham & Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Krystal L Parker
- Carver College of Medicine, University of Iowa, Iowa City, Iowa, USA
| | - Timothy Y Mariano
- Department of Psychiatry, Brigham & Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA; Butler Hospital, Providence, Rhode Island, USA; Center for Neurorestoration and Neurotechnology, Providence Veterans Affairs Medical Center, Providence, Rhode Island, USA
| |
Collapse
|
33
|
Joe H, Pahk KJ, Park S, Kim H. Development of a subject-specific guide system for Low-Intensity Focused Ultrasound (LIFU) brain stimulation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 176:105-110. [PMID: 31200898 DOI: 10.1016/j.cmpb.2019.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 05/05/2019] [Accepted: 05/05/2019] [Indexed: 06/09/2023]
Abstract
Low-Intensity Focused Ultrasound (LIFU) has recently been considered as a promising neuromodulation technique because it can noninvasively stimulate the brain with a high spatial resolution. As spatial resolution is improved, there is a growing demand for developing more accurate and convenient guide systems. Therefore, in the present study, we have developed and prototyped a 3D printed wearable subject-specific helmet for LIFU stimulation that is guaranteed to be accurate. The spatial relationship between the target position and the full-width at half-maximum (FWHM) of acoustic pressure of the transducer, i.e. focal volume, was compared using the conventional image-guided navigation system. According to the distribution of positional errors, the target position was located well within the focal volume.
Collapse
Affiliation(s)
- Haeyoung Joe
- Center for Bionics, Biomedical Research Institute, Korea Institute Science and Technology (KIST), 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea; Human-Machine Systems Laboratory, Dept. of Mechanical Engineering, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Ki Joo Pahk
- Center for Bionics, Biomedical Research Institute, Korea Institute Science and Technology (KIST), 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea
| | - Shinsuk Park
- Human-Machine Systems Laboratory, Dept. of Mechanical Engineering, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
| | - Hyungmin Kim
- Center for Bionics, Biomedical Research Institute, Korea Institute Science and Technology (KIST), 5, Hwarangro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea.
| |
Collapse
|
34
|
Mohammadi L, Behnam H, Tavakkoli J, Avanaki MRN. Skull's Photoacoustic Attenuation and Dispersion Modeling with Deterministic Ray-Tracing: Towards Real-Time Aberration Correction. SENSORS (BASEL, SWITZERLAND) 2019; 19:E345. [PMID: 30654543 PMCID: PMC6359310 DOI: 10.3390/s19020345] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 01/10/2019] [Accepted: 01/14/2019] [Indexed: 12/25/2022]
Abstract
Although transcranial photoacoustic imaging has been previously investigated by several groups, there are many unknowns about the distorting effects of the skull due to the impedance mismatch between the skull and underlying layers. The current computational methods based on finite-element modeling are slow, especially in the cases where fine grids are defined for a large 3-D volume. We develop a very fast modeling/simulation framework based on deterministic ray-tracing. The framework considers a multilayer model of the medium, taking into account the frequency-dependent attenuation and dispersion effects that occur in wave reflection, refraction, and mode conversion at the skull surface. The speed of the proposed framework is evaluated. We validate the accuracy of the framework using numerical phantoms and compare its results to k-Wave simulation results. Analytical validation is also performed based on the longitudinal and shear wave transmission coefficients. We then simulated, using our method, the major skull-distorting effects including amplitude attenuation, time-domain signal broadening, and time shift, and confirmed the findings by comparing them to several ex vivo experimental results. It is expected that the proposed method speeds up modeling and quantification of skull tissue and allows the development of transcranial photoacoustic brain imaging.
Collapse
Affiliation(s)
- Leila Mohammadi
- Department of Biomedical Engineering, Islamic Azad University, Science and Research Branch, Tehran 1477893855, Iran.
| | - Hamid Behnam
- Department of Biomedical Engineering, Iran University of Science and Technology, Tehran 1684613114, Iran.
| | - Jahan Tavakkoli
- Department of Physics, Ryerson University, Toronto, ON M5B 2K3, Canada.
- Institute for Biomedical Engineering, Science and Technology (iBEST), Keenan Research Center for Biomedical Science, St. Michael's Hospital, Toronto, ON M5B 1W8, Canada.
| | - Mohammad R N Avanaki
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48202, USA.
- Department of Dermatology, Wayne State University School of Medicine, Detroit, MI 48201, USA.
- Barbara Ann Karmanos Cancer Institute, Detroit, MI 48201, USA.
| |
Collapse
|
35
|
Lee W, Croce P, Margolin RW, Cammalleri A, Yoon K, Yoo SS. Transcranial focused ultrasound stimulation of motor cortical areas in freely-moving awake rats. BMC Neurosci 2018; 19:57. [PMID: 30231861 PMCID: PMC6146769 DOI: 10.1186/s12868-018-0459-3] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Accepted: 09/15/2018] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Low-intensity transcranial focused ultrasound (tFUS) has emerged as a new non-invasive modality of brain stimulation with the potential for high spatial selectivity and penetration depth. Anesthesia is typically applied in animal-based tFUS brain stimulation models; however, the type and depth of anesthesia are known to introduce variability in responsiveness to the stimulation. Therefore, the ability to conduct sonication experiments on awake small animals, such as rats, is warranted to avoid confounding effects of anesthesia. RESULTS We developed a miniature tFUS headgear, operating at 600 kHz, which can be attached to the skull of Sprague-Dawley rats through an implanted pedestal, allowing the ultrasound to be transcranially delivered to motor cortical areas of unanesthetized freely-moving rats. Video recordings were obtained to monitor physical responses from the rat during acoustic brain stimulation. The stimulation elicited body movements from various areas, such as the tail, limbs, and whiskers. Movement of the head, including chewing behavior, was also observed. When compared to the light ketamine/xylazine and isoflurane anesthetic conditions, the response rate increased while the latency to stimulation decreased in the awake condition. The individual variability in response rates was smaller during the awake condition compared to the anesthetic conditions. Our analysis of latency distribution of responses also suggested possible presence of acoustic startle responses mixed with stimulation-related physical movement. Post-tFUS monitoring of animal behaviors and histological analysis performed on the brain did not reveal any abnormalities after the repeated tFUS sessions. CONCLUSIONS The wearable miniature tFUS configuration allowed for the stimulation of motor cortical areas in rats and elicited sonication-related movements under both awake and anesthetized conditions. The awake condition yielded diverse physical responses compared to those reported in existing literatures. The ability to conduct an experiment in freely-moving awake animals can be gainfully used to investigate the effects of acoustic neuromodulation free from the confounding effects of anesthesia, thus, may serve as a translational platform to large animals and humans.
Collapse
Affiliation(s)
- Wonhye Lee
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 USA
| | - Phillip Croce
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 USA
| | - Ryan W. Margolin
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 USA
| | - Amanda Cammalleri
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 USA
| | - Kyungho Yoon
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 USA
| |
Collapse
|
36
|
Yoo SS. Technical Review and Perspectives of Transcranial Focused Ultrasound Brain Stimulation for Neurorehabilitation. BRAIN & NEUROREHABILITATION 2018. [DOI: 10.12786/bn.2018.11.e16] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Affiliation(s)
- Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|