1
|
Tamaki A, Uenishi S, Yamada S, Yasuda K, Ikeda N, Tabata M, Kita A, Mizutani-Tiebel Y, Keeser D, Padberg F, Tsuji T, Kimoto S, Takahashi S. Female sex and age-based advantage of simulated electric field in TMS to the prefrontal cortex in schizophrenia and mood disorders. Psychiatry Res Neuroimaging 2024; 342:111844. [PMID: 38901089 DOI: 10.1016/j.pscychresns.2024.111844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 06/03/2024] [Accepted: 06/04/2024] [Indexed: 06/22/2024]
Abstract
This study investigates computational models of electric field strength for transcranial magnetic stimulation (TMS) of the left dorsolateral prefrontal cortex (DLPFC) based on individual MRI data of patients with schizophrenia (SZ), major depressive disorder (MDD), bipolar disorder (BP), and healthy controls (HC). In addition, it explores the association of electric field intensities with age, gender and intracranial volume. The subjects were 23 SZ (12 male, mean age = 45.30), 24 MDD (16 male, mean age = 43.57), 23 BP (16 male, mean age = 39.29), 23 HC (13 male, mean age = 40.91). Based on individual MRI sequences, electric fields were computationally modeled by two independent investigators using SimNIBS ver. 2.1.1. There was no significant difference in electric field strength between the groups (HC vs SZ, HC vs MDD, HC vs BP, SZ vs MDD, SZ vs BP, MDD vs BP). Female subjects showed higher electric field intensities in widespread areas than males, and age was positively significantly associated with electric field strength in the left parahippocampal area as observed. Our results suggest differences in electric field strength of left DLPFC TMS for gender and age. It may open future avenues for individually modeling TMS based on structural MRI data.
Collapse
Affiliation(s)
- Atsushi Tamaki
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan; Department of Psychiatry, Wakayama Prefectural Mental Health Care Center, Wakayama, 643-0811, Japan.
| | - Shinya Uenishi
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan; Department of Psychiatry, Hidaka Hospital, Gobo 6440002, Wakayama, Japan
| | - Shinichi Yamada
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan
| | - Kasumi Yasuda
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan
| | - Natsuko Ikeda
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan
| | - Michiyo Tabata
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan
| | - Akira Kita
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan
| | - Yuki Mizutani-Tiebel
- Department of Psychiatry and Psychotherapy, LMU University Hospital Munich, 80336, Munich, Germany
| | - Daniel Keeser
- Department of Psychiatry and Psychotherapy, LMU University Hospital Munich, 80336, Munich, Germany; Department of Radiology, LMU University Hospital Munich, 81377, Munich, Germany; Munich Center for Neurosciences (MCN) Brain & Mind, Planegg-Martinsried 82152, Munich, Germany
| | - Frank Padberg
- Department of Psychiatry and Psychotherapy, LMU University Hospital Munich, 80336, Munich, Germany
| | - Tomikimi Tsuji
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan
| | - Sohei Kimoto
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan
| | - Shun Takahashi
- Department of Neuropsychiatry, Wakayama Medical University, Wakayama 6410012, Wakayama, Japan; Department of Psychiatry, Osaka University Graduate School of Medicine, Suita 5650871, Osaka, Japan; Graduate School of Rehabilitation Science, Osaka Metropolitan University, Habikino 5838555, Osaka, Japan; Clinical Research and Education Center, Asakayama General Hospital, Sakai 5900018, Osaka, Japan
| |
Collapse
|
2
|
Camera F, Merla C, De Santis V. Comparison of Transcranial Magnetic Stimulation Dosimetry between Structured and Unstructured Grids Using Different Solvers. Bioengineering (Basel) 2024; 11:712. [PMID: 39061794 PMCID: PMC11273852 DOI: 10.3390/bioengineering11070712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Revised: 07/05/2024] [Accepted: 07/10/2024] [Indexed: 07/28/2024] Open
Abstract
In recent years, the interest in transcranial magnetic stimulation (TMS) has surged, necessitating deeper understanding, development, and use of low-frequency (LF) numerical dosimetry for TMS studies. While various ad hoc dosimetric models exist, commercial software tools like SimNIBS v4.0 and Sim4Life v7.2.4 are preferred for their user-friendliness and versatility. SimNIBS utilizes unstructured tetrahedral mesh models, while Sim4Life employs voxel-based models on a structured grid, both evaluating induced electric fields using the finite element method (FEM) with different numerical solvers. Past studies primarily focused on uniform exposures and voxelized models, lacking realism. Our study compares these LF solvers across simplified and realistic anatomical models to assess their accuracy in evaluating induced electric fields. We examined three scenarios: a single-shell sphere, a sphere with an orthogonal slab, and a MRI-derived head model. The comparison revealed small discrepancies in induced electric fields, mainly in regions of low field intensity. Overall, the differences were contained (below 2% for spherical models and below 12% for the head model), showcasing the potential of computational tools in advancing exposure assessment required for TMS protocols in different bio-medical applications.
Collapse
Affiliation(s)
- Francesca Camera
- Division of Biotechnologies, Italian National Agency for Energy, New Technologies and Sustainable Economic Development (ENEA), 00123 Rome, Italy;
| | - Caterina Merla
- Division of Biotechnologies, Italian National Agency for Energy, New Technologies and Sustainable Economic Development (ENEA), 00123 Rome, Italy;
| | - Valerio De Santis
- Department of Industrial and Information Engineering and Economics, University of L’Aquila, 67100 L’Aquila, Italy;
| |
Collapse
|
3
|
Robins PL, Makaroff SN, Dib M, Lisanby SH, Deng ZD. Electric Field Characteristics of Rotating Permanent Magnet Stimulation. Bioengineering (Basel) 2024; 11:258. [PMID: 38534532 PMCID: PMC10968657 DOI: 10.3390/bioengineering11030258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 02/26/2024] [Accepted: 03/03/2024] [Indexed: 03/28/2024] Open
Abstract
Neurostimulation devices that use rotating permanent magnets are being explored for their potential therapeutic benefits in patients with psychiatric and neurological disorders. This study aims to characterize the electric field (E-field) for ten configurations of rotating magnets using finite element analysis and phantom measurements. Various configurations were modeled, including single or multiple magnets, and bipolar or multipolar magnets, rotated at 10, 13.3, and 350 revolutions per second (rps). E-field strengths were also measured using a hollow sphere (r=9.2 cm) filled with a 0.9% sodium chloride solution and with a dipole probe. The E-field spatial distribution is determined by the magnets' dimensions, number of poles, direction of the magnetization, and axis of rotation, while the E-field strength is determined by the magnets' rotational frequency and magnetic field strength. The induced E-field strength on the surface of the head ranged between 0.0092 and 0.52 V/m. In the range of rotational frequencies applied, the induced E-field strengths were approximately an order or two of magnitude lower than those delivered by conventional transcranial magnetic stimulation. The impact of rotational frequency on E-field strength represents a confound in clinical trials that seek to tailor rotational frequency to individual neural oscillations. This factor could explain some of the variability observed in clinical trial outcomes.
Collapse
Affiliation(s)
- Pei L. Robins
- Computational Neurostimulation Research Program, Noninvasive Neuromodulation Unit, Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, Bethesda, MD 20892, USA; (P.L.R.); (S.H.L.)
| | - Sergey N. Makaroff
- Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609, USA;
| | - Michael Dib
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA;
| | - Sarah H. Lisanby
- Computational Neurostimulation Research Program, Noninvasive Neuromodulation Unit, Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, Bethesda, MD 20892, USA; (P.L.R.); (S.H.L.)
| | - Zhi-De Deng
- Computational Neurostimulation Research Program, Noninvasive Neuromodulation Unit, Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, Bethesda, MD 20892, USA; (P.L.R.); (S.H.L.)
| |
Collapse
|
4
|
Fernandes SR, Callejón-Leblic MA, Ferreira HA. How does the electric field induced by tDCS influence motor-related connectivity? Model-guided perspectives. Phys Med Biol 2024; 69:055007. [PMID: 38266295 DOI: 10.1088/1361-6560/ad222d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 01/24/2024] [Indexed: 01/26/2024]
Abstract
Over the last decade, transcranial direct current stimulation (tDCS) has been applied not only to modulate local cortical activation, but also to address communication between functionally-related brain areas. Stimulation protocols based on simple two-electrode placements are being replaced by multi-electrode montages to target intra- and inter-hemispheric neural networks using multichannel/high definition paradigms.Objective. This study aims to investigate the characteristics of electric field (EF) patterns originated by tDCS experiments addressing changes in functional brain connectivity.Methods. A previous selection of tDCS experimental studies aiming to modulate motor-related connectivity in health and disease was conducted. Simulations of the EF induced in the cortex were then performed for each protocol selected. The EF magnitude and orientation are determined and analysed in motor-related cortical regions for five different head models to account for inter-subject variability. Functional connectivity outcomes obtained are qualitatively analysed at the light of the simulated EF and protocol characteristics, such as electrode position, number and stimulation dosing.Main findings. The EF magnitude and orientation predicted by computational models can be related with the ability of tDCS to modulate brain functional connectivity. Regional differences in EF distributions across subjects can inform electrode placements more susceptible to inter-subject variability in terms of brain connectivity-related outcomes.Significance. Neuronal facilitation/inhibition induced by tDCS fields may indirectly influence intra and inter-hemispheric connectivity by modulating neural components of motor-related networks. Optimization of tDCS using computational models is essential for adequate dosing delivery in specific networks related to clinically relevant connectivity outcomes.
Collapse
Affiliation(s)
- Sofia Rita Fernandes
- Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, Portugal
| | - M Amparo Callejón-Leblic
- Oticon Medical, Madrid, Spain
- Grupo de Ingeniería Biomédica, Escuela Técnica Superior de Ingeniería, Universidad de Sevilla, Spain
- Servicio de Otorrinolaringología, Hospital Universitario Virgen Macarena, Sevilla, Spain
| | - Hugo Alexandre Ferreira
- Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, Portugal
| |
Collapse
|
5
|
Wang M, Zhang L, Hong W, Luo Y, Li H, Feng Z. Optimizing intracranial electric field distribution through temperature-driven scalp conductivity adjustments in transcranial electrical stimulation. Phys Med Biol 2024; 69:03NT02. [PMID: 38170996 DOI: 10.1088/1361-6560/ad1a24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Accepted: 01/03/2024] [Indexed: 01/05/2024]
Abstract
Transcranial electrical stimulation (TES) is a promising non-invasive neuromodulation technique. How to increase the current intensity entering the skull and reduce scalp shunting has become a key factor significantly influencing regulatory efficacy. In this study, we introduce a novel approach for optimizing TES by adjusting local scalp temperature to modulate scalp conductivity. We have developed simulation models for TES-induced electric fields and for temperature-induced alterations in scalp conductivity. Two common types of stimulation montage (M1-SO and 4 × 1 montage) were adopted for the evaluation of effectiveness. We observed that the modulation of scalp temperature has a significant impact on the distribution of the electric field within the brain during TES. As local scalp temperature decreases, there is an increase in the maximum electric field intensity within the target area, with the maximum change reaching 18.3%, when compared to the electric field distribution observed under normal scalp temperature conditions. Our study provide insights into the practical implementation challenges and future directions for this innovative methodology.
Collapse
Affiliation(s)
- Minmin Wang
- Key Laboratory of Biomedical Engineering of Education Ministry, Zhejiang Provincial Key Laboratory of Cardio-Cerebral Vascular Detection Technology and Medicinal Effectiveness Appraisal, Department of Biomedical Engineering, School of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, People's Republic of China
- Binjiang Institute of Zhejiang University, Hangzhou, People's Republic of China
| | - Li Zhang
- Department of Neurology, Brain Medical Center, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China
- Center for Rehabilitation Medicine, Rehabilitation & Sports Medicine Research Institute of Zhejiang Province, Department of Rehabilitation Medicine, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, People's Republic of China
| | - Wenjun Hong
- Department of Rehabilitation Medicine, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, People's Republic of China
| | - Yujia Luo
- Department of Pain Management, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China
| | - Han Li
- Department of Pain Management, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China
| | - Zhiying Feng
- Department of Pain Management, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China
| |
Collapse
|
6
|
Natale G, Colella M, De Carluccio M, Lelli D, Paffi A, Carducci F, Apollonio F, Palacios D, Viscomi MT, Liberti M, Ghiglieri V. Astrocyte Responses Influence Local Effects of Whole-Brain Magnetic Stimulation in Parkinsonian Rats. Mov Disord 2023; 38:2173-2184. [PMID: 37700489 DOI: 10.1002/mds.29599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 08/11/2023] [Accepted: 08/21/2023] [Indexed: 09/14/2023] Open
Abstract
BACKGROUND Excessive glutamatergic transmission in the striatum is implicated in Parkinson's disease (PD) progression. Astrocytes maintain glutamate homeostasis, protecting from excitotoxicity through the glutamate-aspartate transporter (GLAST), whose alterations have been reported in PD. Noninvasive brain stimulation using intermittent theta-burst stimulation (iTBS) acts on striatal neurons and glia, inducing neuromodulatory effects and functional recovery in experimental parkinsonism. OBJECTIVE Because PD is associated with altered astrocyte function, we hypothesized that acute iTBS, known to rescue striatal glutamatergic transmission, exerts regional- and cell-specific effects through modulation of glial functions. METHODS 6-Hydroxydopamine-lesioned rats were exposed to acute iTBS, and the areas predicted to be more responsive by a biophysical, hyper-realistic computational model that faithfully reconstructs the experimental setting were analyzed. The effects of iTBS on glial cells and motor behavior were evaluated by molecular and morphological analyses, and CatWalk and Stepping test, respectively. RESULTS As predicted by the model, the hippocampus, cerebellum, and striatum displayed a marked c-FOS activation after iTBS, with the striatum showing specific morphological and molecular changes in the astrocytes, decreased phospho-CREB levels, and recovery of GLAST. Striatal-dependent motor performances were also significantly improved. CONCLUSION These data uncover an unknown iTBS effect on astrocytes, advancing the understanding of the complex mechanisms involved in TMS-mediated functional recovery. Data on numerical dosimetry, obtained with a degree of anatomical details never before considered and validated by the biological findings, provide a framework to predict the electric-field induced in different specific brain areas and associate it with functional and molecular changes. © 2023 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.
Collapse
Affiliation(s)
- Giuseppina Natale
- Department of Neuroscience, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Micol Colella
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy
| | - Maria De Carluccio
- Department of Neuroscience, Università Cattolica del Sacro Cuore, Rome, Italy
- Department of Neurosciences and Neurorehabilitation, IRCCS San Raffaele Pisana, Rome, Italy
| | - Daniele Lelli
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy
| | - Alessandra Paffi
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy
| | - Filippo Carducci
- Neuroimaging Laboratory, Department of Physiology and Pharmacology "Vitorio Erspamer", Sapienza University of Rome, Rome, Italy
| | - Francesca Apollonio
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy
| | - Daniela Palacios
- Department of Life Sciences and Public Health, Section of Histology and Embryology, Università Cattolica del Sacro Cuore, Rome, Italy
- Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Maria Teresa Viscomi
- Department of Life Sciences and Public Health, Section of Histology and Embryology, Università Cattolica del Sacro Cuore, Rome, Italy
- Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Micaela Liberti
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, Rome, Italy
| | - Veronica Ghiglieri
- Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Department of Human Sciences and Quality of Life Promotion, San Raffaele University, Rome, Italy
| |
Collapse
|
7
|
Van Hoornweder S, Nuyts M, Frieske J, Verstraelen S, Meesen RLJ, Caulfield KA. Outcome measures for electric field modeling in tES and TMS: A systematic review and large-scale modeling study. Neuroimage 2023; 281:120379. [PMID: 37716590 PMCID: PMC11008458 DOI: 10.1016/j.neuroimage.2023.120379] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/18/2023] [Accepted: 09/13/2023] [Indexed: 09/18/2023] Open
Abstract
BACKGROUND Electric field (E-field) modeling is a potent tool to estimate the amount of transcranial magnetic and electrical stimulation (TMS and tES, respectively) that reaches the cortex and to address the variable behavioral effects observed in the field. However, outcome measures used to quantify E-fields vary considerably and a thorough comparison is missing. OBJECTIVES This two-part study aimed to examine the different outcome measures used to report on tES and TMS induced E-fields, including volume- and surface-level gray matter, region of interest (ROI), whole brain, geometrical, structural, and percentile-based approaches. The study aimed to guide future research in informed selection of appropriate outcome measures. METHODS Three electronic databases were searched for tES and/or TMS studies quantifying E-fields. The identified outcome measures were compared across volume- and surface-level E-field data in ten tES and TMS modalities targeting two common targets in 100 healthy individuals. RESULTS In the systematic review, we extracted 308 outcome measures from 202 studies that adopted either a gray matter volume-level (n = 197) or surface-level (n = 111) approach. Volume-level results focused on E-field magnitude, while surface-level data encompassed E-field magnitude (n = 64) and normal/tangential E-field components (n = 47). E-fields were extracted in ROIs, such as brain structures and shapes (spheres, hexahedra and cylinders), or the whole brain. Percentiles or mean values were mostly used to quantify E-fields. Our modeling study, which involved 1,000 E-field models and > 1,000,000 extracted E-field values, revealed that different outcome measures yielded distinct E-field values, analyzed different brain regions, and did not always exhibit strong correlations in the same within-subject E-field model. CONCLUSIONS Outcome measure selection significantly impacts the locations and intensities of extracted E-field data in both tES and TMS E-field models. The suitability of different outcome measures depends on the target region, TMS/tES modality, individual anatomy, the analyzed E-field component and the research question. To enhance the quality, rigor, and reproducibility in the E-field modeling domain, we suggest standard reporting practices across studies and provide four recommendations.
Collapse
Affiliation(s)
- Sybren Van Hoornweder
- REVAL - Rehabilitation Research Center, Faculty of Rehabilitation Sciences, University of Hasselt, Diepenbeek, Belgium.
| | - Marten Nuyts
- REVAL - Rehabilitation Research Center, Faculty of Rehabilitation Sciences, University of Hasselt, Diepenbeek, Belgium
| | - Joana Frieske
- REVAL - Rehabilitation Research Center, Faculty of Rehabilitation Sciences, University of Hasselt, Diepenbeek, Belgium; Movement Control and Neuroplasticity Research Group, Department of Movement Sciences, Group Biomedical Sciences, KU Leuven, Leuven, Belgium
| | - Stefanie Verstraelen
- REVAL - Rehabilitation Research Center, Faculty of Rehabilitation Sciences, University of Hasselt, Diepenbeek, Belgium
| | - Raf L J Meesen
- REVAL - Rehabilitation Research Center, Faculty of Rehabilitation Sciences, University of Hasselt, Diepenbeek, Belgium; Movement Control and Neuroplasticity Research Group, Department of Movement Sciences, Group Biomedical Sciences, KU Leuven, Leuven, Belgium
| | - Kevin A Caulfield
- Brain Stimulation Laboratory, Department of Psychiatry, Medical University of South Carolina, Charleston, SC, United States.
| |
Collapse
|
8
|
Van Hoornweder S, Nuyts M, Frieske J, Verstraelen S, Meesen RLJ, Caulfield KA. A Systematic Review and Large-Scale tES and TMS Electric Field Modeling Study Reveals How Outcome Measure Selection Alters Results in a Person- and Montage-Specific Manner. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.02.22.529540. [PMID: 36865243 PMCID: PMC9980068 DOI: 10.1101/2023.02.22.529540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
Background Electric field (E-field) modeling is a potent tool to examine the cortical effects of transcranial magnetic and electrical stimulation (TMS and tES, respectively) and to address the high variability in efficacy observed in the literature. However, outcome measures used to report E-field magnitude vary considerably and have not yet been compared in detail. Objectives The goal of this two-part study, encompassing a systematic review and modeling experiment, was to provide an overview of the different outcome measures used to report the magnitude of tES and TMS E-fields, and to conduct a direct comparison of these measures across different stimulation montages. Methods Three electronic databases were searched for tES and/or TMS studies reporting E-field magnitude. We extracted and discussed outcome measures in studies meeting the inclusion criteria. Additionally, outcome measures were compared via models of four common tES and two TMS modalities in 100 healthy younger adults. Results In the systematic review, we included 118 studies using 151 outcome measures related to E-field magnitude. Structural and spherical regions of interest (ROI) analyses and percentile-based whole-brain analyses were used most often. In the modeling analyses, we found that there was an average of only 6% overlap between ROI and percentile-based whole-brain analyses in the investigated volumes within the same person. The overlap between ROI and whole-brain percentiles was montage- and person-specific, with more focal montages such as 4Ã-1 and APPS-tES, and figure-of-eight TMS showing up to 73%, 60%, and 52% overlap between ROI and percentile approaches respectively. However, even in these cases, 27% or more of the analyzed volume still differed between outcome measures in every analyses. Conclusions The choice of outcome measures meaningfully alters the interpretation of tES and TMS E-field models. Well-considered outcome measure selection is imperative for accurate interpretation of results, valid between-study comparisons, and depends on stimulation focality and study goals. We formulated four recommendations to increase the quality and rigor of E-field modeling outcome measures. With these data and recommendations, we hope to guide future studies towards informed outcome measure selection, and improve the comparability of studies.
Collapse
|
9
|
Electric Field Distribution Induced by TMS: Differences Due to Anatomical Variation. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Transcranial magnetic stimulation (TMS) is a well-established technique for the diagnosis and treatment of neuropsychiatric diseases. The numerical calculation of the induced electric field (EF) distribution in the brain increases the efficacy of stimulation and improves clinical outcomes. However, unique anatomical features, which distinguish each subject, suggest that personalized models should be preferentially used. The objective of the present study was to assess how anatomy affects the EF distribution and to determine to what extent personalized models are useful for clinical studies. The head models of nineteen healthy volunteers were automatically segmented. Two versions of each head model, a homogeneous and a five-tissue anatomical, were stimulated by the model of a Hesed coil (H-coil), employing magnetic quasi-static simulations. The H-coil was placed at two standard stimulating positions per model, over the frontal and central areas. The results show small, but indisputable, variations in the EFs for the homogeneous and anatomical models. The interquartile ranges in the anatomical versions were higher compared to the homogeneous ones, indicating that individual anatomical features may affect the prediction of stimulation volumes. It is concluded that personalized models provide complementary information and should be preferably employed in the context of diagnostic and therapeutic TMS studies.
Collapse
|