1
|
Hirata A, Akazawa Y, Kodera S, Otsuru N, Laakso I. Electric field envelope focality in superficial brain areas with linear alignment montage in temporal interference stimulation. Comput Biol Med 2024; 178:108697. [PMID: 38850958 DOI: 10.1016/j.compbiomed.2024.108697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 05/13/2024] [Accepted: 06/01/2024] [Indexed: 06/10/2024]
Abstract
Temporal interference stimulation (TIS) uses two pairs of conventional transcranial alternating current stimulation (tACS) electrodes, each with a different frequency, to generate a time-varying electric field (EF) envelope (EFE). The EFE focality in primary somatosensory and motor cortex areas of a standard human brain was computed using newly defined linear alignment montages. Sixty head volume conductor models constructed from magnetic resonance images were considered to evaluate interindividual variability. Six TIS and two tACS electrode montages were considered, including linear and rectangular alignments. EFEs were computed using the scalar-potential finite-difference method. The computed EFE was projected onto the standard brain space for each montage. Computational results showed that TIS and tACS generated different EFE and EF distributions in postcentral and precentral gyri regions. For TIS, the EFE amplitude in the target areas had lower variability than the EF strength of tACS. However, bipolar tACS montages showed higher focality in the superficial postcentral and precentral gyri regions than in TIS. TIS generated greater EFE penetration than bipolar tACS at depths <5-10 mm below the brain surface. From group-level analysis, tACS with a bipolar montage was preferred for targets <5-10 mm in depth (gyral crowns) and TIS for deeper targets. TIS with a linear alignment montage could be an effective method for deep structures and sulcal walls. These findings provide valuable insights into the choice of TIS and tACS for stimulating specific brain regions.
Collapse
Affiliation(s)
- Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan; Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Japan.
| | - Yusuke Akazawa
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
| | - Sachiko Kodera
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan; Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Japan
| | - Naofumi Otsuru
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
| | - Ilkka Laakso
- Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| |
Collapse
|
2
|
Dannhauer M, Gomez LJ, Robins PL, Wang D, Hasan NI, Thielscher A, Siebner HR, Fan Y, Deng ZD. Electric Field Modeling in Personalizing Transcranial Magnetic Stimulation Interventions. Biol Psychiatry 2024; 95:494-501. [PMID: 38061463 PMCID: PMC10922371 DOI: 10.1016/j.biopsych.2023.11.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 11/21/2023] [Accepted: 11/25/2023] [Indexed: 01/21/2024]
Abstract
The modeling of transcranial magnetic stimulation (TMS)-induced electric fields (E-fields) is a versatile technique for evaluating and refining brain targeting and dosing strategies, while also providing insights into dose-response relationships in the brain. This review outlines the methodologies employed to derive E-field estimations, covering TMS physics, modeling assumptions, and aspects of subject-specific head tissue and coil modeling. We also summarize various numerical methods for solving the E-field and their suitability for various applications. Modeling methodologies have been optimized to efficiently execute numerous TMS simulations across diverse scalp coil configurations, facilitating the identification of optimal setups or rapid cortical E-field visualization for specific brain targets. These brain targets are extrapolated from neurophysiological measurements and neuroimaging, enabling precise and individualized E-field dosing in experimental and clinical applications. This necessitates the quantification of E-field estimates using metrics that enable the comparison of brain target engagement, functional localization, and TMS intensity adjustments across subjects. The integration of E-field modeling with empirical data has the potential to uncover pivotal insights into the aspects of E-fields responsible for stimulating and modulating brain function and states, enhancing behavioral task performance, and impacting the clinical outcomes of personalized TMS interventions.
Collapse
Affiliation(s)
- Moritz Dannhauer
- Computational Neurostimulation Research Program, Noninvasive Neuromodulation Unit, Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, Bethesda, Maryland
| | - Luis J Gomez
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana
| | - Pei L Robins
- Computational Neurostimulation Research Program, Noninvasive Neuromodulation Unit, Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, Bethesda, Maryland
| | - Dezhi Wang
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana
| | - Nahian I Hasan
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana
| | - Axel Thielscher
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark; Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Hartwig R Siebner
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark; Department of Neurology, Copenhagen University Hospital Bispebjerg, Copenhagen, Denmark; Institute for Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Yong Fan
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Zhi-De Deng
- Computational Neurostimulation Research Program, Noninvasive Neuromodulation Unit, Experimental Therapeutics and Pathophysiology Branch, National Institute of Mental Health, Bethesda, Maryland.
| |
Collapse
|
3
|
Nishimoto H, Kodera S, Otsuru N, Hirata A. Individual and group-level optimization of electric field in deep brain region during multichannel transcranial electrical stimulation. Front Neurosci 2024; 18:1332135. [PMID: 38529268 PMCID: PMC10961445 DOI: 10.3389/fnins.2024.1332135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 02/19/2024] [Indexed: 03/27/2024] Open
Abstract
Electrode montage optimization for transcranial electric stimulation (tES) is a challenging topic for targeting a specific brain region. Targeting the deep brain region is difficult due to tissue inhomogeneity, resulting in complex current flow. In this study, a simplified protocol for montage optimization is proposed for multichannel tES (mc-tES). The purpose of this study was to reduce the computational cost for mc-tES optimization and to evaluate the mc-tES for deep brain regions. Optimization was performed using a simplified protocol for montages under safety constraints with 20 anatomical head models. The optimization procedure is simplified using the surface EF of the deep brain target region, considering its small volume and non-concentric distribution of the electrodes. Our proposal demonstrated that the computational cost was reduced by >90%. A total of six-ten electrodes were necessary for robust EF in the target region. The optimization with surface EF is comparable to or marginally better than using conventional volumetric EF for deep brain tissues. An electrode montage with a mean injection current amplitude derived from individual analysis was demonstrated to be useful for targeting the deep region at the group level. The optimized montage and injection current were derived at the group level. Our proposal at individual and group levels showed great potential for clinical application.
Collapse
Affiliation(s)
- Hidetaka Nishimoto
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
| | - Sachiko Kodera
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Japan
| | - Naofumi Otsuru
- Institute for Human Movement and Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan
- Department of Physical Therapy, Niigata University of Health and Welfare, Niigata, Japan
| | - Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Japan
| |
Collapse
|
4
|
Hikita K, Gomez-Tames J, Hirata A. Mapping Brain Motor Functions Using Transcranial Magnetic Stimulation with a Volume Conductor Model and Electrophysiological Experiments. Brain Sci 2023; 13:brainsci13010116. [PMID: 36672097 PMCID: PMC9856731 DOI: 10.3390/brainsci13010116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 12/26/2022] [Accepted: 01/05/2023] [Indexed: 01/11/2023] Open
Abstract
Transcranial magnetic stimulation (TMS) activates brain cells in a noninvasive manner and can be used for mapping brain motor functions. However, the complexity of the brain anatomy prevents the determination of the exact location of the stimulated sites, resulting in the limitation of the spatial resolution of multiple targets. The aim of this study is to map two neighboring muscles in cortical motor areas accurately and quickly. Multiple stimuli were applied to the subject using a TMS stimulator to measure the motor-evoked potentials (MEPs) in the corresponding muscles. For each stimulation condition (coil location and angle), the induced electric field (EF) in the brain was computed using a volume conductor model for an individualized head model of the subject constructed from magnetic resonance images. A post-processing method was implemented to determine a TMS hotspot using EF corresponding to multiple stimuli, considering the amplitude of the measured MEPs. The dependence of the computationally estimated hotspot distribution on two target muscles was evaluated (n = 11). The center of gravity of the first dorsal interosseous cortical representation was lateral to the abductor digiti minimi by a minimum of 2 mm. The localizations were consistent with the putative sites obtained from previous EF-based studies and fMRI studies. The simultaneous cortical mapping of two finger muscles was achieved with only several stimuli, which is one or two orders of magnitude smaller than that in previous studies. Our proposal would be useful in the preoperative mapping of motor or speech areas to plan brain surgery interventions.
Collapse
Affiliation(s)
- Keigo Hikita
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Aichi, Japan
| | - Jose Gomez-Tames
- Center for Frontier Medical Engineering, Chiba University, Chiba 263-8522, Chiba, Japan
| | - Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Aichi, Japan
- Correspondence:
| |
Collapse
|
5
|
Nieminen AE, Nieminen JO, Stenroos M, Novikov P, Nazarova M, Vaalto S, Nikulin V, Ilmoniemi RJ. Accuracy and precision of navigated transcranial magnetic stimulation. J Neural Eng 2022; 19. [PMID: 36541458 DOI: 10.1088/1741-2552/aca71a] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 11/29/2022] [Indexed: 12/02/2022]
Abstract
Objective.Transcranial magnetic stimulation (TMS) induces an electric field (E-field) in the cortex. To facilitate stimulation targeting, image-guided neuronavigation systems have been introduced. Such systems track the placement of the coil with respect to the head and visualize the estimated cortical stimulation location on an anatomical brain image in real time. The accuracy and precision of the neuronavigation is affected by multiple factors. Our aim was to analyze how different factors in TMS neuronavigation affect the accuracy and precision of the coil-head coregistration and the estimated E-field.Approach.By performing simulations, we estimated navigation errors due to distortions in magnetic resonance images (MRIs), head-to-MRI registration (landmark- and surface-based registrations), localization and movement of the head tracker, and localization of the coil tracker. We analyzed the effect of these errors on coil and head coregistration and on the induced E-field as determined with simplistic and realistic head models.Main results.Average total coregistration accuracies were in the range of 2.2-3.6 mm and 1°; precision values were about half of the accuracy values. The coregistration errors were mainly due to head-to-MRI registration with average accuracies 1.5-1.9 mm/0.2-0.4° and precisions 0.5-0.8 mm/0.1-0.2° better with surface-based registration. The other major source of error was the movement of the head tracker with average accuracy of 1.5 mm and precision of 1.1 mm. When assessed within an E-field method, the average accuracies of the peak E-field location, orientation, and magnitude ranged between 1.5 and 5.0 mm, 0.9 and 4.8°, and 4.4 and 8.5% across the E-field models studied. The largest errors were obtained with the landmark-based registration. When computing another accuracy measure with the most realistic E-field model as a reference, the accuracies tended to improve from about 10 mm/15°/25% to about 2 mm/2°/5% when increasing realism of the E-field model.Significance.The results of this comprehensive analysis help TMS operators to recognize the main sources of error in TMS navigation and that the coregistration errors and their effect in the E-field estimation depend on the methods applied. To ensure reliable TMS navigation, we recommend surface-based head-to-MRI registration and realistic models for E-field computations.
Collapse
Affiliation(s)
- Aino E Nieminen
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland.,AMI Centre, Aalto NeuroImaging, Aalto University School of Science, Espoo, Finland
| | - Jaakko O Nieminen
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
| | - Matti Stenroos
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
| | - Pavel Novikov
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland.,Centre for Cognition and Decision Making, Institute for Cognitive Neuroscience, National Research University Higher School of Economics, Moscow, Russia
| | - Maria Nazarova
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland.,Centre for Cognition and Decision Making, Institute for Cognitive Neuroscience, National Research University Higher School of Economics, Moscow, Russia.,Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States of America
| | - Selja Vaalto
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland.,HUS Diagnostic Center, Clinical Neurophysiology, Clinical Neurosciences, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Vadim Nikulin
- Centre for Cognition and Decision Making, Institute for Cognitive Neuroscience, National Research University Higher School of Economics, Moscow, Russia.,Department of Neurology, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Risto J Ilmoniemi
- Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
| |
Collapse
|
6
|
Beumer S, Boon P, Klooster DCW, van Ee R, Carrette E, Paulides MM, Mestrom RMC. Personalized tDCS for Focal Epilepsy—A Narrative Review: A Data-Driven Workflow Based on Imaging and EEG Data. Brain Sci 2022; 12:brainsci12050610. [PMID: 35624997 PMCID: PMC9139054 DOI: 10.3390/brainsci12050610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 05/03/2022] [Accepted: 05/05/2022] [Indexed: 02/01/2023] Open
Abstract
Conventional transcranial electric stimulation(tES) using standard anatomical positions for the electrodes and standard stimulation currents is frequently not sufficiently selective in targeting and reaching specific brain locations, leading to suboptimal application of electric fields. Recent advancements in in vivo electric field characterization may enable clinical researchers to derive better relationships between the electric field strength and the clinical results. Subject-specific electric field simulations could lead to improved electrode placement and more efficient treatments. Through this narrative review, we present a processing workflow to personalize tES for focal epilepsy, for which there is a clear cortical target to stimulate. The workflow utilizes clinical imaging and electroencephalography data and enables us to relate the simulated fields to clinical outcomes. We review and analyze the relevant literature for the processing steps in the workflow, which are the following: tissue segmentation, source localization, and stimulation optimization. In addition, we identify shortcomings and ongoing trends with regard to, for example, segmentation quality and tissue conductivity measurements. The presented processing steps result in personalized tES based on metrics like focality and field strength, which allow for correlation with clinical outcomes.
Collapse
Affiliation(s)
- Steven Beumer
- Department of Electrical Engineering, University of Technology Eindhoven, P.O. Box 513, 5600 MB Eindhoven, The Netherlands; (P.B.); (D.C.W.K.); (E.C.); (M.M.P.); (R.M.C.M.)
- Correspondence:
| | - Paul Boon
- Department of Electrical Engineering, University of Technology Eindhoven, P.O. Box 513, 5600 MB Eindhoven, The Netherlands; (P.B.); (D.C.W.K.); (E.C.); (M.M.P.); (R.M.C.M.)
- Department of Neurology, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium
| | - Debby C. W. Klooster
- Department of Electrical Engineering, University of Technology Eindhoven, P.O. Box 513, 5600 MB Eindhoven, The Netherlands; (P.B.); (D.C.W.K.); (E.C.); (M.M.P.); (R.M.C.M.)
- Department of Neurology, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium
| | - Raymond van Ee
- Philips Research Eindhoven, High Tech Campus 34, 5656 AE Eindhoven, The Netherlands;
| | - Evelien Carrette
- Department of Electrical Engineering, University of Technology Eindhoven, P.O. Box 513, 5600 MB Eindhoven, The Netherlands; (P.B.); (D.C.W.K.); (E.C.); (M.M.P.); (R.M.C.M.)
- Department of Neurology, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium
| | - Maarten M. Paulides
- Department of Electrical Engineering, University of Technology Eindhoven, P.O. Box 513, 5600 MB Eindhoven, The Netherlands; (P.B.); (D.C.W.K.); (E.C.); (M.M.P.); (R.M.C.M.)
- Department of Radiation Oncology, Erasmus Medical Center Cancer Institute, Burgemeester Oudlaan 50, 3062 PA Rotterdam, The Netherlands
| | - Rob M. C. Mestrom
- Department of Electrical Engineering, University of Technology Eindhoven, P.O. Box 513, 5600 MB Eindhoven, The Netherlands; (P.B.); (D.C.W.K.); (E.C.); (M.M.P.); (R.M.C.M.)
| |
Collapse
|
7
|
Zhang H, Gomez L, Guilleminot J. Uncertainty quantification of TMS simulations considering MRI segmentation errors. J Neural Eng 2022; 19. [PMID: 35169105 DOI: 10.1088/1741-2552/ac5586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 02/08/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Transcranial Magnetic Stimulation (TMS) is a non-invasive brain stimulation method that is used to study brain function and conduct neuropsychiatric therapy. Computational methods that are commonly used for electric field (E-field) dosimetry of TMS are limited in accuracy and precision because of possible geometric errors introduced in the generation of head models by segmenting medical images into tissue types. This paper studies E-field prediction fidelity as a function of segmentation accuracy. APPROACH The errors in the segmentation of medical images into tissue types are modeled as geometric uncertainty in the shape of the boundary between tissue types. For each tissue boundary realization, we then use an in-house boundary element method to perform a forward propagation analysis and quantify the impact of tissue boundary uncertainties on the induced cortical E-field. MAIN RESULTS Our results indicate that predictions of E-field induced in the brain are negligibly sensitive to segmentation errors in scalp, skull and white matter, compartments. In contrast, E-field predictions are highly sensitive to possible CSF segmentation errors. Specifically, the segmentation errors on the CSF and gray matter interface lead to higher E-field uncertainties in the gyral crowns, and the segmentation errors on CSF and white matter interface lead to higher uncertainties in the sulci. Furthermore, the uncertainty of the average cortical E-fields over a region exhibits lower uncertainty relative to point-wise estimates. SIGNIFICANCE The accuracy of current cortical E-field simulations is limited by the accuracy of CSF segmentation accuracy. Other quantities of interest like the average of the E-field over a cortical region could provide a dose quantity that is robust to possible segmentation errors.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Civil and Environmental Engineering, Duke University, 121 Hudson Hall, Durham, 27708-0187, UNITED STATES
| | - Luis Gomez
- Elmore Family School of Electrical and Computer Engineering, Purdue University, 465 Northwestern Ave., West Lafayette, Indiana, 47907-2050, UNITED STATES
| | - Johann Guilleminot
- Duke University, 121 Hudson Hall, Durham, North Carolina, 27708-0187, UNITED STATES
| |
Collapse
|
8
|
Moridera T, Rashed EA, Mizutani S, Hirata A. High-Resolution EEG Source Localization in Segmentation-Free Head Models Based on Finite-Difference Method and Matching Pursuit Algorithm. Front Neurosci 2021; 15:695668. [PMID: 34262433 PMCID: PMC8273249 DOI: 10.3389/fnins.2021.695668] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 06/04/2021] [Indexed: 11/23/2022] Open
Abstract
Electroencephalogram (EEG) is a method to monitor electrophysiological activity on the scalp, which represents the macroscopic activity of the brain. However, it is challenging to identify EEG source regions inside the brain based on data measured by a scalp-attached network of electrodes. The accuracy of EEG source localization significantly depends on the type of head modeling and inverse problem solver. In this study, we adopted different models with a resolution of 0.5 mm to account for thin tissues/fluids, such as the cerebrospinal fluid (CSF) and dura. In particular, a spatially dependent conductivity (segmentation-free) model created using deep learning was developed and used for more realist representation of electrical conductivity. We then adopted a multi-grid-based finite-difference method (FDM) for forward problem analysis and a sparse-based algorithm to solve the inverse problem. This enabled us to perform efficient source localization using high-resolution model with a reasonable computational cost. Results indicated that the abrupt spatial change in conductivity, inherent in conventional segmentation-based head models, may trigger source localization error accumulation. The accurate modeling of the CSF, whose conductivity is the highest in the head, was an important factor affecting localization accuracy. Moreover, computational experiments with different noise levels and electrode setups demonstrate the robustness of the proposed method with segmentation-free head model.
Collapse
Affiliation(s)
- Takayoshi Moridera
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
| | - Essam A Rashed
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan.,Department of Mathematics, Faculty of Science, Suez Canal University, Ismailia, Egypt
| | - Shogo Mizutani
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan
| | - Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Nagoya, Japan.,Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Japan
| |
Collapse
|