Henry B, Merz M, Hoang H, Abdulkarim G, Wosik J, Schoettker P. Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits. Blood Press 2024; 33:2304190. [PMID: 38245864 DOI: 10.1080/08037051.2024.2304190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 01/07/2024] [Indexed: 01/22/2024]
Abstract
Background: Cuffless blood pressure measurement technologies have attracted significant attention for their potential to transform cardiovascular monitoring.Methods: This updated narrative review thoroughly examines the challenges, opportunities, and limitations associated with the implementation of cuffless blood pressure monitoring systems.Results: Diverse technologies, including photoplethysmography, tonometry, and ECG analysis, enable cuffless blood pressure measurement and are integrated into devices like smartphones and smartwatches. Signal processing emerges as a critical aspect, dictating the accuracy and reliability of readings. Despite its potential, the integration of cuffless technologies into clinical practice faces obstacles, including the need to address concerns related to accuracy, calibration, and standardization across diverse devices and patient populations. The development of robust algorithms to mitigate artifacts and environmental disturbances is essential for extracting clear physiological signals. Based on extensive research, this review emphasizes the necessity for standardized protocols, validation studies, and regulatory frameworks to ensure the reliability and safety of cuffless blood pressure monitoring devices and their implementation in mainstream medical practice. Interdisciplinary collaborations between engineers, clinicians, and regulatory bodies are crucial to address technical, clinical, and regulatory complexities during implementation. In conclusion, while cuffless blood pressure monitoring holds immense potential to transform cardiovascular care. The resolution of existing challenges and the establishment of rigorous standards are imperative for its seamless incorporation into routine clinical practice.Conclusion: The emergence of these new technologies shifts the paradigm of cardiovascular health management, presenting a new possibility for non-invasive continuous and dynamic monitoring. The concept of cuffless blood pressure measurement is viable and more finely tuned devices are expected to enter the market, which could redefine our understanding of blood pressure and hypertension.
Collapse
Affiliation(s)
- Benoit Henry
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Maxime Merz
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Harry Hoang
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ghaith Abdulkarim
- Neuro-Informatics Laboratory, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
| | - Jedrek Wosik
- Department of Medicine, Duke University School of Medicine, Durham, North Carolina
| | - Patrick Schoettker
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
2
|
Li J, Chu H, Chen Z, Yiu CK, Qu Q, Li Z, Yu X. Recent Advances in Materials, Devices and Algorithms Toward Wearable Continuous Blood Pressure Monitoring. ACS NANO 2024; 18:17407-17438. [PMID: 38923501 DOI: 10.1021/acsnano.4c04291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Continuous blood pressure (BP) tracking provides valuable insights into the health condition and functionality of the heart, arteries, and overall circulatory system of humans. The rapid development in flexible and wearable electronics has significantly accelerated the advancement of wearable BP monitoring technologies. However, several persistent challenges, including limited sensing capabilities and stability of flexible sensors, poor interfacial stability between sensors and skin, and low accuracy in BP estimation, have hindered the progress in wearable BP monitoring. To address these challenges, comprehensive innovations in materials design, device development, system optimization, and modeling have been pursued to improve the overall performance of wearable BP monitoring systems. In this review, we highlight the latest advancements in flexible and wearable systems toward continuous noninvasive BP tracking with a primary focus on materials development, device design, system integration, and theoretical algorithms. Existing challenges, potential solutions, and further research directions are also discussed to provide theoretical and technical guidance for the development of future wearable systems in continuous ambulatory BP measurement with enhanced sensing capability, robustness, and long-term accuracy.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Hongwei Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China
| | - Zhenlin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qing'ao Qu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zhiyuan Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057, China
- Hong Kong Institute for Clean Energy, City University of Hong Kong, Kowloon, Hong Kong, China
| |
Collapse
|
3
|
Lai K, Wang X, Cao C. A Continuous Non-Invasive Blood Pressure Prediction Method Based on Deep Sparse Residual U-Net Combined with Improved Squeeze and Excitation Skip Connections. SENSORS (BASEL, SWITZERLAND) 2024; 24:2721. [PMID: 38732827 PMCID: PMC11086107 DOI: 10.3390/s24092721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 04/09/2024] [Accepted: 04/19/2024] [Indexed: 05/13/2024]
Abstract
Arterial blood pressure (ABP) serves as a pivotal clinical metric in cardiovascular health assessments, with the precise forecasting of continuous blood pressure assuming a critical role in both preventing and treating cardiovascular diseases. This study proposes a novel continuous non-invasive blood pressure prediction model, DSRUnet, based on deep sparse residual U-net combined with improved SE skip connections, which aim to enhance the accuracy of using photoplethysmography (PPG) signals for continuous blood pressure prediction. The model first introduces a sparse residual connection approach for path contraction and expansion, facilitating richer information fusion and feature expansion to better capture subtle variations in the original PPG signals, thereby enhancing the network's representational capacity and predictive performance and mitigating potential degradation in the network performance. Furthermore, an enhanced SE-GRU module was embedded in the skip connections to model and weight global information using an attention mechanism, capturing the temporal features of the PPG pulse signals through GRU layers to improve the quality of the transferred feature information and reduce redundant feature learning. Finally, a deep supervision mechanism was incorporated into the decoder module to guide the lower-level network to learn effective feature representations, alleviating the problem of gradient vanishing and facilitating effective training of the network. The proposed DSRUnet model was trained and tested on the publicly available UCI-BP dataset, with the average absolute errors for predicting systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) being 3.36 ± 6.61 mmHg, 2.35 ± 4.54 mmHg, and 2.21 ± 4.36 mmHg, respectively, meeting the standards set by the Association for the Advancement of Medical Instrumentation (AAMI), and achieving Grade A according to the British Hypertension Society (BHS) Standard for SBP and DBP predictions. Through ablation experiments and comparisons with other state-of-the-art methods, the effectiveness of DSRUnet in blood pressure prediction tasks, particularly for SBP, which generally yields poor prediction results, was significantly higher. The experimental results demonstrate that the DSRUnet model can accurately utilize PPG signals for real-time continuous blood pressure prediction and obtain high-quality and high-precision blood pressure prediction waveforms. Due to its non-invasiveness, continuity, and clinical relevance, the model may have significant implications for clinical applications in hospitals and research on wearable devices in daily life.
Collapse
Affiliation(s)
- Kaixuan Lai
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| | - Xusheng Wang
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| | - Congjun Cao
- The Faculty of Printing, Packaging Engineering and Digital Media Technology, Xi’an University of Technology, Xi’an 710048, China; (K.L.); (X.W.)
- The Printing and Packaging Engineering Technology Research Center of Shaanxi Province, Xi’an 710048, China
| |
Collapse
|
4
|
Nishan A, M. Taslim Uddin Raju S, Hossain MI, Dipto SA, M. Tanvir Uddin S, Sijan A, Chowdhury MAS, Ahmad A, Mahamudul Hasan Khan M. A continuous cuffless blood pressure measurement from optimal PPG characteristic features using machine learning algorithms. Heliyon 2024; 10:e27779. [PMID: 38533045 PMCID: PMC10963242 DOI: 10.1016/j.heliyon.2024.e27779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/01/2024] [Accepted: 03/06/2024] [Indexed: 03/28/2024] Open
Abstract
Background and objective Hypertension is a potentially dangerous health condition that can be detected by measuring blood pressure (BP). Blood pressure monitoring and measurement are essential for preventing and treating cardiovascular diseases. Cuff-based devices, on the other hand, are uncomfortable and prevent continuous BP measurement. Methods In this study, a new non-invasive and cuff-less method for estimating Systolic Blood Pressure (SBP), Mean Arterial Pressure (MAP), and Diastolic Blood Pressure (DBP) has been proposed using characteristic features of photoplethysmogram (PPG) signals and nonlinear regression algorithms. PPG signals were collected from 219 participants, which were then subjected to preprocessing and feature extraction steps. Analyzing PPG and its derivative signals, a total of 46 time, frequency, and time-frequency domain features were extracted. In addition, the age and gender of each subject were also included as features. Further, correlation-based feature selection (CFS) and Relief F feature selection (ReliefF) techniques were used to select the relevant features and reduce the possibility of over-fitting the models. Finally, support vector regression (SVR), K-nearest neighbour regression (KNR), decision tree regression (DTR), and random forest regression (RFR) were established to develop the BP estimation model. Regression models were trained and evaluated on all features as well as selected features. The best regression models for SBP, MAP, and DBP estimations were selected separately. Results The SVR model, along with the ReliefF-based feature selection algorithm, outperforms other algorithms in estimating the SBP, MAP, and DBP with the mean absolute error of 2.49, 1.62 and 1.43 mmHg, respectively. The proposed method meets the Advancement of Medical Instrumentation standard for BP estimations. Based on the British Hypertension Society standard, the results also fall within Grade A for SBP, MAP, and DBP. Conclusion The findings show that the method can be used to estimate blood pressure non-invasively, without using a cuff or calibration, and only by utilizing the PPG signal characteristic features.
Collapse
Affiliation(s)
- Araf Nishan
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - S. M. Taslim Uddin Raju
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Md Imran Hossain
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Safin Ahmed Dipto
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - S. M. Tanvir Uddin
- Department of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur, Bangladesh
| | - Asif Sijan
- Department of Software Engineering, American International University, Dhaka, Bangladesh
| | - Md Abu Shahid Chowdhury
- Department of Biomedical Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Ashfaq Ahmad
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| | - Md Mahamudul Hasan Khan
- Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh
| |
Collapse
|
5
|
Dong S, Wang Q, Wang S, Zhou C, Wang H. Hypotension prediction index for the prevention of hypotension during surgery and critical care: A narrative review. Comput Biol Med 2024; 170:107995. [PMID: 38325215 DOI: 10.1016/j.compbiomed.2024.107995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/17/2023] [Accepted: 01/13/2024] [Indexed: 02/09/2024]
Abstract
Surgeons and anesthesia clinicians commonly face a hemodynamic disturbance known as intraoperative hypotension (IOH), which has been linked to more severe postoperative outcomes and increases mortality rates. Increased occurrence of IOH has been positively associated with mortality and incidence of myocardial infarction, stroke, and organ dysfunction hypertension. Hence, early detection and recognition of IOH is meaningful for perioperative management. Currently, when hypotension occurs, clinicians use vasopressor or fluid therapy to intervene as IOH develops but interventions should be taken before hypotension occurs; therefore, the Hypotension Prediction Index (HPI) method can be used to help clinicians further react to the IOH process. This literature review evaluates the HPI method, which can reliably predict hypotension several minutes before a hypotensive event and is beneficial for patients' outcomes.
Collapse
Affiliation(s)
- Siwen Dong
- The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou 310053, China
| | - Qing Wang
- Department of Anesthesiology, Tongde Hospital of Zhejiang Province, Hangzhou 310012, China
| | - Shuai Wang
- The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou 310053, China
| | - Congcong Zhou
- Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, China; Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou 310027, China
| | - Hongwei Wang
- The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou 310053, China; Department of Anesthesiology, Tongde Hospital of Zhejiang Province, Hangzhou 310012, China.
| |
Collapse
|
6
|
Park S, Lee S, Park E, Lee J, Kim IY. Quantitative analysis of pulse arrival time and PPG morphological features based cuffless blood pressure estimation: a comparative study between diabetic and non-diabetic groups. Biomed Eng Lett 2023; 13:625-636. [PMID: 37872987 PMCID: PMC10590356 DOI: 10.1007/s13534-023-00284-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 05/09/2023] [Accepted: 05/12/2023] [Indexed: 10/25/2023] Open
Abstract
Pulse arrival time (PAT) and PPG morphological features have attracted much interest in cuffless blood pressure (BP) estimation, but their effects are not clearly understood when vascular characteristics are affected by diseases such as diabetes. This work quantitatively analyzes the effect of diabetic disease on the PAT and PPG morphological features-based BP estimation. We selected 112 diabetic patients and 308 non-diabetic subjects from VitalDB, and extracted 16 features including PAT, PPG morphological features, and heart rate. BP estimation performance was statistically compared between groups using linear regression models with several feature sets, and the relative importance of each feature in the optimal feature set was extracted. As a result, the standard deviation of the error and mean absolute error of PAT-based BP estimation were significantly higher in the diabetic group than in the non-diabetic group (p < 0.01). A feature set containing PAT and PPG morphological features achieved the best performance in both groups. However, the relative importance of each feature for BP estimation differed notably between groups. The results indicate that different features are important depending on the vascular characteristics, which could help to construct different models to accommodate specific diseases.
Collapse
Affiliation(s)
- Seongryul Park
- Department of Electronic Engineering, Hanyang University, Seoul, 04763 South Korea
| | | | - Eunkyoung Park
- Department of Biomedical Engineering, Soonchunhyang University, Asan, 31538 South Korea
| | - Jongshill Lee
- Department of Biomedical Engineering, Hanyang University, Seoul, 04763 South Korea
| | - In Young Kim
- Department of Biomedical Engineering, Hanyang University, Seoul, 04763 South Korea
| |
Collapse
|
7
|
Ma G, Zhang J, Liu J, Wang L, Yu Y. A Multi-Parameter Fusion Method for Cuffless Continuous Blood Pressure Estimation Based on Electrocardiogram and Photoplethysmogram. MICROMACHINES 2023; 14:804. [PMID: 37421037 DOI: 10.3390/mi14040804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/27/2023] [Accepted: 03/29/2023] [Indexed: 07/09/2023]
Abstract
Blood pressure (BP) is an essential physiological indicator to identify and determine health status. Compared with the isolated BP measurement conducted by traditional cuff approaches, cuffless BP monitoring can reflect the dynamic changes in BP values and is more helpful to evaluate the effectiveness of BP control. In this paper, we designed a wearable device for continuous physiological signal acquisition. Based on the collected electrocardiogram (ECG) and photoplethysmogram (PPG), we proposed a multi-parameter fusion method for noninvasive BP estimation. An amount of 25 features were extracted from processed waveforms and Gaussian copula mutual information (MI) was introduced to reduce feature redundancy. After feature selection, random forest (RF) was trained to realize systolic BP (SBP) and diastolic BP (DBP) estimation. Moreover, we used the records in public MIMIC-III as the training set and private data as the testing set to avoid data leakage. The mean absolute error (MAE) and standard deviation (STD) for SBP and DBP were reduced from 9.12 ± 9.83 mmHg and 8.31 ± 9.23 mmHg to 7.93 ± 9.12 mmHg and 7.63 ± 8.61 mmHg by feature selection. After calibration, the MAE was further reduced to 5.21 mmHg and 4.15 mmHg. The result showed that MI has great potential in feature selection during BP prediction and the proposed multi-parameter fusion method can be used for long-term BP monitoring.
Collapse
Affiliation(s)
- Gang Ma
- School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| | - Jie Zhang
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| | - Jing Liu
- School of Electronics and Information Technology, Soochow University, Suzhou 215031, China
| | - Lirong Wang
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
- School of Electronics and Information Technology, Soochow University, Suzhou 215031, China
| | - Yong Yu
- Suzhou Institute of Biomedical Engineering and Technology, China Academy of Sciences, Suzhou 215163, China
| |
Collapse
|
8
|
Qin K, Huang W, Zhang T, Tang S. Machine learning and deep learning for blood pressure prediction: a methodological review from multiple perspectives. Artif Intell Rev 2022. [DOI: 10.1007/s10462-022-10353-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
9
|
Liu Z, Zhou C, Wang H, He Y. Blood pressure monitoring techniques in the natural state of multi-scenes: A review. Front Med (Lausanne) 2022; 9:851172. [PMID: 36091712 PMCID: PMC9462511 DOI: 10.3389/fmed.2022.851172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 08/11/2022] [Indexed: 11/17/2022] Open
Abstract
Blood pressure is one of the basic physiological parameters of human physiology. Frequent and repeated measurement of blood pressure along with recording of environmental or other physiological parameters when measuring blood pressure may reveal important cardiovascular risk factors that can predict occurrence of cardiovascular events. Currently, wearable non-invasive blood pressure measurement technology has attracted much research attention. Several different technical routes have been proposed to solve the challenge between portability or continuity of measurement methods and medical level accuracy of measurement results. The accuracy of blood pressure measurement technology based on auscultation and oscillography has been clinically verified, while majority of other technical routes are being explored at laboratory or multi-center clinical demonstration stage. Normally, Blood pressure measurement based on oscillographic method outside the hospital can only be measured at intervals. There is a need to develop techniques for frequent and high-precision blood pressure measurement under natural conditions outside the hospital. In this paper, we discussed the current status of blood pressure measurement technology and development trends of blood pressure measurement technology in different scenarios. We focuses on the key technical challenges and the latest advances in the study of miniaturization devices based on oscillographic method at wrist and PTT related method at finger positions as well as technology processes. This study is of great significance to the application of high frequency blood pressure measurement technology.
Collapse
Affiliation(s)
- Ziyi Liu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
- Guangdong Transtek Medical Electronics Co., Ltd., Zhongshan, China
| | - Congcong Zhou
- Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, China
- Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, China
| | - Hongwei Wang
- Tongde Hospital of Zhejiang Province, Hangzhou, China
- *Correspondence: Hongwei Wang,
| | - Yong He
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
- Yong He,
| |
Collapse
|