1
|
Collavini S, Pérez JJ, Berjano E, Fernández-Corazza M, Oddo S, Irastorza RM. Impact of surrounding tissue-type and peri-electrode gap in stereoelectroencephalography guided (SEEG) radiofrequency thermocoagulation (RF-TC): a computational study. Int J Hyperthermia 2024; 41:2364721. [PMID: 38880496 DOI: 10.1080/02656736.2024.2364721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 06/01/2024] [Indexed: 06/18/2024] Open
Abstract
PURPOSE To use computational modeling to provide a complete and logical description of the electrical and thermal behavior during stereoelectroencephalography-guided (SEEG) radiofrequency thermo-coagulation (RF-TC). METHODS A coupled electrical-thermal model was used to obtain the temperature distributions in the tissue during RF-TC. The computer model was first validated by an ex vivo model based on liver fragments and later used to study the impact of three different factors on the coagulation zone size: 1) the difference in the tissue surrounding the electrode (gray/white matter), 2) the presence of a peri-electrode gap occupied by cerebrospinal fluid (CSF), and 3) the energy setting used (power-duration). RESULTS The model built for the experimental validation was able to predict both the evolution of impedance and the short diameter of the coagulation zone (error < 0.01 mm) reasonably well but overestimated the long diameter by 2 - 3 mm. After adapting the model to clinical conditions, the simulation showed that: 1) Impedance roll-off limited the coagulation size but involved overheating (around 100 °C); 2) The type of tissue around the contacts (gray vs. white matter) had a moderate impact on the coagulation size (maximum difference 0.84 mm), and 3) the peri-electrode gap considerably altered the temperature distributions, avoided overheating, although the diameter of the coagulation zone was not very different from the no-gap case (<0.2 mm). CONCLUSIONS This study showed that computer modeling, especially subject- and scenario-specific modeling, can be used to estimate in advance the electrical and thermal performance of the RF-TC in brain tissue.
Collapse
Affiliation(s)
- Santiago Collavini
- Institute of Engineering and Agronomy, National University Arturo Jauretche, Buenos Aires, Argentina
- Neurosciences and Complex Systems Unit (EnyS), CONICET, Hosp. "El Cruce N. Kirchner", National University A. Jauretche (UNAJ), Buenos Aires, Argentina
| | - Juan J Pérez
- BioMIT, Departamento de Ingeniería Electrónica, Universitat Politècnica de València, València, Spain
| | - Enrique Berjano
- BioMIT, Departamento de Ingeniería Electrónica, Universitat Politècnica de València, València, Spain
| | - Mariano Fernández-Corazza
- Research Institute of Electronics, Control and Signal Processing (LEICI), National University of La Plata-CONICET, La Plata, Argentina
| | - Silvia Oddo
- Neurosciences and Complex Systems Unit (EnyS), CONICET, Hosp. "El Cruce N. Kirchner", National University A. Jauretche (UNAJ), Buenos Aires, Argentina
| | - Ramiro M Irastorza
- Institute of Engineering and Agronomy, National University Arturo Jauretche, Buenos Aires, Argentina
- Institute of Physics of Liquids and Biological Systems (IFLySiB CONICET La Plata), La Plata, Argentina
- Granular Materials Group, Department of Mechanical Engineering, La Plata Regional Faculty, National Technological University, La Plata, Argentina
| |
Collapse
|
2
|
Gomez-Tames J, Fernández-Corazza M. Perspectives on Optimized Transcranial Electrical Stimulation Based on Spatial Electric Field Modeling in Humans. J Clin Med 2024; 13:3084. [PMID: 38892794 PMCID: PMC11172989 DOI: 10.3390/jcm13113084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 05/20/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024] Open
Abstract
Background: Transcranial electrical stimulation (tES) generates an electric field (or current density) in the brain through surface electrodes attached to the scalp. Clinical significance has been demonstrated, although with moderate and heterogeneous results partly due to a lack of control of the delivered electric currents. In the last decade, computational electric field analysis has allowed the estimation and optimization of the electric field using accurate anatomical head models. This review examines recent tES computational studies, providing a comprehensive background on the technical aspects of adopting computational electric field analysis as a standardized procedure in medical applications. Methods: Specific search strategies were designed to retrieve papers from the Web of Science database. The papers were initially screened based on the soundness of the title and abstract and then on their full contents, resulting in a total of 57 studies. Results: Recent trends were identified in individual- and population-level analysis of the electric field, including head models from non-neurotypical individuals. Advanced optimization techniques that allow a high degree of control with the required focality and direction of the electric field were also summarized. There is also growing evidence of a correlation between the computationally estimated electric field and the observed responses in real experiments. Conclusions: Computational pipelines and optimization algorithms have reached a degree of maturity that provides a rationale to improve tES experimental design and a posteriori analysis of the responses for supporting clinical studies.
Collapse
Affiliation(s)
- Jose Gomez-Tames
- Department of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan
- Center for Frontier Medical Engineering, Chiba University, Chiba 263-8522, Japan
| | - Mariano Fernández-Corazza
- LEICI Institute of Research in Electronics, Control and Signal Processing, National University of La Plata, La Plata 1900, Argentina
| |
Collapse
|
3
|
Blenkmann AO, Leske SL, Llorens A, Lin JJ, Chang EF, Brunner P, Schalk G, Ivanovic J, Larsson PG, Knight RT, Endestad T, Solbakk AK. Anatomical registration of intracranial electrodes. Robust model-based localization and deformable smooth brain-shift compensation methods. J Neurosci Methods 2024; 404:110056. [PMID: 38224783 DOI: 10.1016/j.jneumeth.2024.110056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 11/27/2023] [Accepted: 01/03/2024] [Indexed: 01/17/2024]
Abstract
BACKGROUND Intracranial electrodes are typically localized from post-implantation CT artifacts. Automatic algorithms localizing low signal-to-noise ratio artifacts and high-density electrode arrays are missing. Additionally, implantation of grids/strips introduces brain deformations, resulting in registration errors when fusing post-implantation CT and pre-implantation MR images. Brain-shift compensation methods project electrode coordinates to cortex, but either fail to produce smooth solutions or do not account for brain deformations. NEW METHODS We first introduce GridFit, a model-based fitting approach that simultaneously localizes all electrodes' CT artifacts in grids, strips, or depth arrays. Second, we present CEPA, a brain-shift compensation algorithm combining orthogonal-based projections, spring-mesh models, and spatial regularization constraints. RESULTS We tested GridFit on ∼6000 simulated scenarios. The localization of CT artifacts showed robust performance under difficult scenarios, such as noise, overlaps, and high-density implants (<1 mm errors). Validation with data from 20 challenging patients showed 99% accurate localization of the electrodes (3160/3192). We tested CEPA brain-shift compensation with data from 15 patients. Projections accounted for simple mechanical deformation principles with < 0.4 mm errors. The inter-electrode distances smoothly changed across neighbor electrodes, while changes in inter-electrode distances linearly increased with projection distance. COMPARISON WITH EXISTING METHODS GridFit succeeded in difficult scenarios that challenged available methods and outperformed visual localization by preserving the inter-electrode distance. CEPA registration errors were smaller than those obtained for well-established alternatives. Additionally, modeling resting-state high-frequency activity in five patients further supported CEPA. CONCLUSION GridFit and CEPA are versatile tools for registering intracranial electrode coordinates, providing highly accurate results even in the most challenging implantation scenarios. The methods are implemented in the iElectrodes open-source toolbox.
Collapse
Affiliation(s)
- Alejandro Omar Blenkmann
- Department of Psychology, University of Oslo, Norway; RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway.
| | - Sabine Liliana Leske
- Department of Musicology, University of Oslo, Norway; RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway; Department of Neuropsychology, Helgeland Hospital, Mosjøen, Norway
| | - Anaïs Llorens
- Department of Psychology, University of Oslo, Norway; Department of Psychology and the Helen Wills Neuroscience Institute, University of California, Berkeley, USA; Université de Franche-Comté, SUPMICROTECH, CNRS, Institut FEMTO-ST, 25000 Besançon, France; Université Paris Cité, Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, Team TURC, 75014 Paris, France
| | - Jack J Lin
- Department of Neurology and Center for Mind and Brain, University of California, Davis, USA
| | - Edward F Chang
- Department of Neurological Surgery, University of California, San Francisco, USA
| | - Peter Brunner
- Department of Neurology, Albany Medical College, Albany, NY, USA; National Center for Adaptive Neurotechnologies, Albany, NY, USA; Department of Neurosurgery, Washington University School of Medicine, St. Louis, MO, USA
| | - Gerwin Schalk
- Department of Neurology, Albany Medical College, Albany, NY, USA; National Center for Adaptive Neurotechnologies, Albany, NY, USA; Tianqiao and Chrissy Chen Institute, Chen Frontier Lab for Applied Neurotechnology, Shanghai, China; Fudan University/Huashan Hospital, Department of Neurosurgery, Shanghai, China
| | | | | | - Robert Thomas Knight
- Department of Psychology and the Helen Wills Neuroscience Institute, University of California, Berkeley, USA
| | - Tor Endestad
- Department of Psychology, University of Oslo, Norway; RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway; Department of Neuropsychology, Helgeland Hospital, Mosjøen, Norway
| | - Anne-Kristin Solbakk
- Department of Psychology, University of Oslo, Norway; RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway; Department of Neurosurgery, Oslo University Hospital, Norway; Department of Neuropsychology, Helgeland Hospital, Mosjøen, Norway
| |
Collapse
|
4
|
Blenkmann AO, Leske SL, Llorens A, Lin JJ, Chang E, Brunner P, Schalk G, Ivanovic J, Larsson PG, Knight RT, Endestad T, Solbakk AK. Anatomical registration of intracranial electrodes. Robust model-based localization and deformable smooth brain-shift compensation methods. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.05.08.539503. [PMID: 37214984 PMCID: PMC10197594 DOI: 10.1101/2023.05.08.539503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Precise electrode localization is important for maximizing the utility of intracranial EEG data. Electrodes are typically localized from post-implantation CT artifacts, but algorithms can fail due to low signal-to-noise ratio, unrelated artifacts, or high-density electrode arrays. Minimizing these errors usually requires time-consuming visual localization and can still result in inaccurate localizations. In addition, surgical implantation of grids and strips typically introduces non-linear brain deformations, which result in anatomical registration errors when post-implantation CT images are fused with the pre-implantation MRI images. Several projection methods are currently available, but they either fail to produce smooth solutions or do not account for brain deformations. To address these shortcomings, we propose two novel algorithms for the anatomical registration of intracranial electrodes that are almost fully automatic and provide highly accurate results. We first present GridFit, an algorithm that simultaneously localizes all contacts in grids, strips, or depth arrays by fitting flexible models to the electrodes' CT artifacts. We observed localization errors of less than one millimeter (below 8% relative to the inter-electrode distance) and robust performance under the presence of noise, unrelated artifacts, and high-density implants when we ran ~6000 simulated scenarios. Furthermore, we validated the method with real data from 20 intracranial patients. As a second registration step, we introduce CEPA, a brain-shift compensation algorithm that combines orthogonal-based projections, spring-mesh models, and spatial regularization constraints. When tested with real data from 15 patients, anatomical registration errors were smaller than those obtained for well-established alternatives. Additionally, CEPA accounted simultaneously for simple mechanical deformation principles, which is not possible with other available methods. Inter-electrode distances of projected coordinates smoothly changed across neighbor electrodes, while changes in inter-electrode distances linearly increased with projection distance. Moreover, in an additional validation procedure, we found that modeling resting-state high-frequency activity (75-145 Hz ) in five patients further supported our new algorithm. Together, GridFit and CEPA constitute a versatile set of tools for the registration of subdural grid, strip, and depth electrode coordinates that provide highly accurate results even in the most challenging implantation scenarios. The methods presented here are implemented in the iElectrodes open-source toolbox, making their use simple, accessible, and straightforward to integrate with other popular toolboxes used for analyzing electrophysiological data.
Collapse
Affiliation(s)
- Alejandro Omar Blenkmann
- Department of Psychology, University of Oslo, Norway
- RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway
| | - Sabine Liliana Leske
- Department of Musicology, University of Oslo, Norway
- RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway
| | - Anaïs Llorens
- Department of Psychology, University of Oslo, Norway
- Department of Psychology and the Helen Wills Neuroscience Institute, University of California, Berkeley, USA
| | - Jack J. Lin
- Department of Neurology and Center for Mind and Brain, University of California, Davis, USA
| | - Edward Chang
- Department of Neurological Surgery, University of California, San Francisco, USA
| | - Peter Brunner
- Department of Neurology, Albany Medical College, Albany, NY, USA
- National Center for Adaptive Neurotechnologies, Albany, NY, USA
| | - Gerwin Schalk
- Department of Neurology, Albany Medical College, Albany, NY, USA
- National Center for Adaptive Neurotechnologies, Albany, NY, USA
- Tianqiao and Chrissy Chen Institute, Chen Frontier Lab for Applied Neurotechnology, Shanghai, China
- Fudan University/Huashan Hospital, Department of Neurosurgery, Shanghai, China
| | | | | | - Robert Thomas Knight
- Department of Psychology and the Helen Wills Neuroscience Institute, University of California, Berkeley, USA
| | - Tor Endestad
- Department of Psychology, University of Oslo, Norway
- RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway
- Department of Neuropsychology, Helgeland Hospital, Mosjøen, Norway
| | - Anne-Kristin Solbakk
- Department of Psychology, University of Oslo, Norway
- RITMO Centre for Interdisciplinary Studies in Rhythm, Time, and Motion, University of Oslo, Norway
- Department of Neurosurgery, Oslo University Hospital, Norway
- Department of Neuropsychology, Helgeland Hospital, Mosjøen, Norway
| |
Collapse
|
5
|
Guo W, He Y, Zhang W, Sun Y, Wang J, Liu S, Ming D. A novel non-invasive brain stimulation technique: "Temporally interfering electrical stimulation". Front Neurosci 2023; 17:1092539. [PMID: 36777641 PMCID: PMC9912300 DOI: 10.3389/fnins.2023.1092539] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/17/2023] [Indexed: 01/30/2023] Open
Abstract
For decades, neuromodulation technology has demonstrated tremendous potential in the treatment of neuropsychiatric disorders. However, challenges such as being less intrusive, more concentrated, using less energy, and better public acceptance, must be considered. Several novel and optimized methods are thus urgently desiderated to overcome these barriers. In specific, temporally interfering (TI) electrical stimulation was pioneered in 2017, which used a low-frequency envelope waveform, generated by the superposition of two high-frequency sinusoidal currents of slightly different frequency, to stimulate specific targets inside the brain. TI electrical stimulation holds the advantages of both spatial targeting and non-invasive character. The ability to activate deep pathogenic targets without surgery is intriguing, and it is expected to be employed to treat some neurological or psychiatric disorders. Recently, efforts have been undertaken to investigate the stimulation qualities and translation application of TI electrical stimulation via computational modeling and animal experiments. This review detailed the most recent scientific developments in the field of TI electrical stimulation, with the goal of serving as a reference for future research.
Collapse
Affiliation(s)
- Wanting Guo
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China
| | - Yuchen He
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China
| | - Wenquan Zhang
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China
| | - Yiwei Sun
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China
| | - Junling Wang
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China
| | - Shuang Liu
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China,*Correspondence: Shuang Liu,
| | - Dong Ming
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China,Department of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China,Tianjin International Joint Research Center for Neural Engineering, Tianjin, China,Dong Ming,
| |
Collapse
|
6
|
Samanta D. Recent developments in stereo electroencephalography monitoring for epilepsy surgery. Epilepsy Behav 2022; 135:108914. [PMID: 36116362 DOI: 10.1016/j.yebeh.2022.108914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 08/31/2022] [Accepted: 09/02/2022] [Indexed: 11/03/2022]
Abstract
Recently the utilization of the stereo electroencephalography (SEEG) method has exploded globally. It is now the preferred method of intracranial monitoring for epilepsy. Since its inception, the basic tenet of the SEEG method remains the same: strategic implantation of intracerebral electrodes based on a hypothesis grounded on anatomo-electroclinical correlation, interpretation of interictal and ictal abnormalities, and formation of a surgical plan based on these data. However, there are recent advancements in all these domains-electrodes implantations, data interpretation, and therapeutic strategy- that can make the SEEG a more accessible and effective approach. In this narrative review, these newer developments are discussed and summarized. Regarding implantation, efficient commercial robotic systems are now increasingly available, which are also more accurate in implanting electrodes. In terms of ictal and interictal abnormalities, newer studies focused on correlating these abnormalities with pathological substrates and surgical outcomes and analyzing high-frequency oscillations and cortical-subcortical connectivity. These abnormalities can now be further quantified using advanced tools (spectrum, spatiotemporal, connectivity analysis, and machine learning algorithms) for objective and efficient interpretation. Another aspect of recent development is renewed interest in SEEG-based electrical stimulation mapping (ESM). The SEEG-ESM has been used in defining epileptogenic networks, mapping eloquent cortex (primarily language), and analyzing cortico-cortical evoked potential. Regarding SEEG-guided direct therapeutic strategy, several clinical studies evaluated the use of radiofrequency thermocoagulation. As the emerging SEEG-based diagnosis and therapeutics are better evolved, treatments aimed at specific epileptogenic networks without compromising the eloquent cortex will become more easily accessible to improve the lives of individuals with drug-resistant epilepsy (DRE).
Collapse
Affiliation(s)
- Debopam Samanta
- Neurology Division, Department of Pediatrics, University of Arkansas for Medical Sciences, Little Rock, AR, United States.
| |
Collapse
|
7
|
Makarov SN, Golestanirad L, Wartman WA, Nguyen BT, Noetscher GM, Ahveninen JP, Fujimoto K, Weise K, Nummenmaa AR. Boundary element fast multipole method for modeling electrical brain stimulation with voltage and current electrodes. J Neural Eng 2021; 18. [PMID: 34311449 DOI: 10.1088/1741-2552/ac17d7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 07/26/2021] [Indexed: 01/03/2023]
Abstract
Objective. To formulate, validate, and apply an alternative to the finite element method (FEM) high-resolution modeling technique for electrical brain stimulation-the boundary element fast multipole method (BEM-FMM). To include practical electrode models for both surface and embedded electrodes.Approach. Integral equations of the boundary element method in terms of surface charge density are combined with a general-purpose fast multipole method and are expanded for voltage, shunt, current, and floating electrodes. The solution of coupled and properly weighted/preconditioned integral equations is accompanied by enforcing global conservation laws: charge conservation law and Kirchhoff's current law.Main results.A sub-percent accuracy is reported as compared to the analytical solutions and simple validation geometries. Comparison to FEM considering realistic head models resulted in relative differences of the electric field magnitude in the range of 3%-6% or less. Quantities that contain higher order spatial derivatives, such as the activating function, are determined with a higher accuracy and a faster speed as compared to the FEM. The method can be easily combined with existing head modeling pipelines such as headreco or mri2mesh.Significance.The BEM-FMM does not rely on a volumetric mesh and is therefore particularly suitable for modeling some mesoscale problems with submillimeter (and possibly finer) resolution with high accuracy at moderate computational cost. Utilizing Helmholtz reciprocity principle makes it possible to expand the method to a solution of EEG forward problems with a very large number of cortical dipoles.
Collapse
Affiliation(s)
- Sergey N Makarov
- Electrical & Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, United States of America.,Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, United States of America
| | - Laleh Golestanirad
- Biomedical Engineering and Radiology Depts., Northwestern University, Chicago, IL 60611, United States of America
| | - William A Wartman
- Electrical & Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, United States of America
| | - Bach Thanh Nguyen
- Biomedical Engineering and Radiology Depts., Northwestern University, Chicago, IL 60611, United States of America
| | - Gregory M Noetscher
- Electrical & Computer Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609, United States of America
| | - Jyrki P Ahveninen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, United States of America
| | - Kyoko Fujimoto
- Center for Devices and Radiological Health (CDRH), FDA, Silver Spring, MD 20993, United States of America
| | - Konstantin Weise
- Max Planck Institute for Human Cognitive and Brain Sciences, Stephanstr. 1a, 04103 Leipzig, Germany
| | - Aapo R Nummenmaa
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, United States of America
| |
Collapse
|