1
|
Hao H, He B, Yu B, Yang J, Xing X, Liu W. Suprachoroidal injection of polyzwitterion hydrogel for treating glaucoma. BIOMATERIALS ADVANCES 2022; 142:213162. [PMID: 36279749 DOI: 10.1016/j.bioadv.2022.213162] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Revised: 09/24/2022] [Accepted: 10/15/2022] [Indexed: 06/16/2023]
Abstract
Glaucoma is the primary cause of irreversible blindness worldwide. The current treatments are primarily based on drug usage or surgical operation to reduce intraocular pressure (IOP). However, it is expensive and requires patients to insist on taking the medicine for a long time. The suprachoroidal space (SCS) is the space between the choroid and the sclera, which forms part of the uveovortex pathway in the circulation of aqueous humor. So far, it is still challenging to realize the injection of hydrogels into the SCS with long-term duration. In this work, an in situ-forming polyzwitterionic polycarboxybetaine hydrogel is designed and injected to expand SCS to increase the drainage of aqueous humor from the eye via the uveovortex pathway, thus reducing IOP for at least 6 weeks, while commercial hyaluronic acid hydrogel can only last for about 4 weeks. The clinical ophthalmological safety assessment examination shows that the treatment of polyzwitterion hydrogel is well-tolerated that leads to minimal inflammatory reaction, and histopathology assessment demonstrates that the SCS is expanded after injection of the hydrogel. Further analysis of ultrasound biomicroscopy reveals that there is a strong correlation between IOP reduction and SCS expansion. In short, the polyzwitterion hydrogel developed in this work can prolong the period of IOP reduction by expanding SCS, thus treating ocular hypertension and glaucoma without resorting to drugs or regular surgery.
Collapse
Affiliation(s)
- Huijie Hao
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Binbin He
- School of Materials Science and Engineering, Tianjin Key Laboratory of Composite and Functional Materials, Tianjin University, Tianjin 300350, China
| | - Bo Yu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China
| | - Jianhai Yang
- School of Materials Science and Engineering, Tianjin Key Laboratory of Composite and Functional Materials, Tianjin University, Tianjin 300350, China.
| | - Xiaoli Xing
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 300384, China.
| | - Wenguang Liu
- School of Materials Science and Engineering, Tianjin Key Laboratory of Composite and Functional Materials, Tianjin University, Tianjin 300350, China
| |
Collapse
|
2
|
Xiong Z, Huang W, Liang Q, Cao Y, Liu S, He Z, Zhang R, Zhang B, Green R, Zhang S, Li D. Harnessing the 2D Structure-Enabled Viscoelasticity of Graphene-Based Hydrogel Membranes for Chronic Neural Interfacing. SMALL METHODS 2022; 6:e2200022. [PMID: 35261208 DOI: 10.1002/smtd.202200022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 02/20/2022] [Indexed: 06/14/2023]
Abstract
Stiffness and viscoelasticity of neural implants regulate the foreign body response. Recent studies have suggested the use of elastic or viscoelastic materials with tissue-like stiffness for long-term neural electrical interfacing. Herein, the authors find that a viscoelastic multilayered graphene hydrogel (MGH) membrane, despite exhibiting a much higher Young's modulus than nerve tissues, shows little inflammatory response after 8-week implantation in rat sciatic nerves. The MGH membrane shows significant viscoelasticity due to the slippage between graphene nanosheets, facilitating its seamless yet minimally compressive interfacing with nerves to reduce the inflammation caused by the stiffness mismatch. When used as neural stimulation electrodes, the MGH membrane can offer abundant ion-accessible surfaces to bring a charge injection capacity 1-2 orders of magnitude higher than its traditional Pt counterpart, and further demonstrates chronic neural therapy potential in low-voltage modulation of rat blood pressure. This work suggests that the emergence of 2D nanomaterials and particularly their unique structural attributes can be harnessed to enable new bio-interfacing design strategies.
Collapse
Affiliation(s)
- Zhiyuan Xiong
- Department of Radiology, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
- Department of Chemical Engineering, The University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Wenhui Huang
- Department of Radiology, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
| | - Qinghua Liang
- Department of Chemical Engineering, The University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Yang Cao
- Department of Chemical Engineering, The University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Shuyi Liu
- Department of Radiology, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
| | - Zicong He
- Department of Radiology, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
| | - Ranran Zhang
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China
| | - Bin Zhang
- Department of Radiology, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
| | - Rylie Green
- Department of Bioengineering, Imperial College, London, SW7 2AZ, UK
| | - Shuixing Zhang
- Department of Radiology, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
| | - Dan Li
- Department of Chemical Engineering, The University of Melbourne, Melbourne, Victoria, 3010, Australia
| |
Collapse
|
3
|
Hadjinicolaou AE, Meffin H, Maturana MI, Cloherty SL, Ibbotson MR. Prosthetic vision: devices, patient outcomes and retinal research. Clin Exp Optom 2021; 98:395-410. [DOI: 10.1111/cxo.12342] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 07/06/2015] [Accepted: 08/04/2015] [Indexed: 12/11/2022] Open
Affiliation(s)
- Alex E Hadjinicolaou
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| | - Hamish Meffin
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| | - Matias I Maturana
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- Department of Electrical and Electronic Engineering, The University of Melbourne, Parkville, Victoria, Australia,
| | - Shaun L Cloherty
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
- Department of Electrical and Electronic Engineering, The University of Melbourne, Parkville, Victoria, Australia,
| | - Michael R Ibbotson
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia,
- ARC Centre of Excellence for Integrative Brain Function and Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia,
| |
Collapse
|
4
|
Richardson RT, Ibbotson MR, Thompson AC, Wise AK, Fallon JB. Optical stimulation of neural tissue. Healthc Technol Lett 2020; 7:58-65. [PMID: 32754339 PMCID: PMC7353819 DOI: 10.1049/htl.2019.0114] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 05/08/2020] [Accepted: 05/15/2020] [Indexed: 12/23/2022] Open
Abstract
Electrical stimulation has been used for decades in devices such as pacemakers, cochlear implants and more recently for deep brain and retinal stimulation and electroceutical treatment of disease. However, current spread from the electrodes limits the precision of neural activation, leading to a low quality therapeutic outcome or undesired side-effects. Alternative methods of neural stimulation such as optical stimulation offer the potential to deliver higher spatial resolution of neural activation. Direct optical stimulation is possible with infrared light, while visible light can be used to activate neurons if the neural tissue is genetically modified with a light sensitive ion channel. Experimentally, both methods have resulted in highly precise stimulation with little spread of activation at least in the cochlea, each with advantages and disadvantages. Infrared neural stimulation does not require modification of the neural tissue, but has very high power requirements. Optogenetics can achieve precision of activation with lower power, but only in conjunction with targeted insertion of a light sensitive ion channel into the nervous system via gene therapy. This review will examine the advantages and limitations of optical stimulation of neural tissue, using the cochlea as an exemplary model and recent developments for retinal and deep brain stimulation.
Collapse
Affiliation(s)
- Rachael Theresa Richardson
- Bionics Institute, Melbourne 3002, Australia.,University of Melbourne, Medical Bionics Department, Melbourne, 3002, Australia.,University of Melbourne, Department of Surgery (Otolaryngology), Melbourne, 3002, Australia
| | - Michael R Ibbotson
- National Vision Research Institute, Australian College of Optometry, and Department of Optometry and Vision Science, University of Melbourne, Melbourne, Australia
| | | | - Andrew K Wise
- Bionics Institute, Melbourne 3002, Australia.,University of Melbourne, Medical Bionics Department, Melbourne, 3002, Australia.,University of Melbourne, Department of Surgery (Otolaryngology), Melbourne, 3002, Australia
| | - James B Fallon
- Bionics Institute, Melbourne 3002, Australia.,University of Melbourne, Medical Bionics Department, Melbourne, 3002, Australia.,University of Melbourne, Department of Surgery (Otolaryngology), Melbourne, 3002, Australia
| |
Collapse
|
5
|
Im M, Kim SW. Neurophysiological and medical considerations for better-performing microelectronic retinal prostheses. J Neural Eng 2020; 17:033001. [PMID: 32329755 DOI: 10.1088/1741-2552/ab8ca9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Maesoon Im
- Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, Republic of Korea. Division of Bio-Medical Science & Technology, KIST School, University of Science and Technology (UST), Seoul, Republic of Korea
| | | |
Collapse
|
6
|
Shim S, Eom K, Jeong J, Kim SJ. Retinal Prosthetic Approaches to Enhance Visual Perception for Blind Patients. MICROMACHINES 2020; 11:E535. [PMID: 32456341 PMCID: PMC7281011 DOI: 10.3390/mi11050535] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 05/22/2020] [Accepted: 05/22/2020] [Indexed: 12/14/2022]
Abstract
Retinal prostheses are implantable devices that aim to restore the vision of blind patients suffering from retinal degeneration, mainly by artificially stimulating the remaining retinal neurons. Some retinal prostheses have successfully reached the stage of clinical trials; however, these devices can only restore vision partially and remain insufficient to enable patients to conduct everyday life independently. The visual acuity of the artificial vision is limited by various factors from both engineering and physiological perspectives. To overcome those issues and further enhance the visual resolution of retinal prostheses, a variety of retinal prosthetic approaches have been proposed, based on optimization of the geometries of electrode arrays and stimulation pulse parameters. Other retinal stimulation modalities such as optics, ultrasound, and magnetics have also been utilized to address the limitations in conventional electrical stimulation. Although none of these approaches have been clinically proven to fully restore the function of a degenerated retina, the extensive efforts made in this field have demonstrated a series of encouraging findings for the next generation of retinal prostheses, and these could potentially enhance the visual acuity of retinal prostheses. In this article, a comprehensive and up-to-date overview of retinal prosthetic strategies is provided, with a specific focus on a quantitative assessment of visual acuity results from various retinal stimulation technologies. The aim is to highlight future directions toward high-resolution retinal prostheses.
Collapse
Affiliation(s)
- Shinyong Shim
- Department of Electrical and Computer Engineering, College of Engineering, Seoul National University, Seoul 08826, Korea;
- Inter-university Semiconductor Research Center, College of Engineering, Seoul National University, Seoul 08826, Korea
| | - Kyungsik Eom
- Department of Electronics Engineering, College of Engineering, Pusan National University, Busan 46241, Korea
| | - Joonsoo Jeong
- School of Biomedical Convergence Engineering, College of Information and Biomedical Engineering, Pusan National University, Yangsan 50612, Korea
| | - Sung June Kim
- Department of Electrical and Computer Engineering, College of Engineering, Seoul National University, Seoul 08826, Korea;
- Inter-university Semiconductor Research Center, College of Engineering, Seoul National University, Seoul 08826, Korea
- Institute on Aging, College of Medicine, Seoul National University, Seoul 08826, Korea
| |
Collapse
|
7
|
Xiao Y, Wang Y, Li F, Lin T, Huffman K, Landeros S, Bosse B, Jing Y, Bartsch DU, Thorogood S, Freeman WR, Cheng L. Acute Rabbit Eye Model for Testing Subretinal Prostheses. Transl Vis Sci Technol 2019; 8:20. [PMID: 31602345 PMCID: PMC6779096 DOI: 10.1167/tvst.8.5.20] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Accepted: 07/23/2019] [Indexed: 11/24/2022] Open
Abstract
Purpose Subretinal prostheses are a novel technology for restoring useful vision in patients with retinitis pigmentosa or age-related macular degeneration. We characterize the surgical implantation technique and functional time window of an acute rabbit eye model for testing of human subretinal prostheses. Methods Retinal prostheses were implanted subretinally in 26 rabbits using a two-step technique. Fundus imaging, fluorescein fundus angiography, and optical coherence topography (OCT) were conducted postoperatively from days 1 to 21 to monitor prosthesis positioning and retinal anatomic changes. Results Successful implantation and excellent retina apposition were achieved in 84.6% of the rabbits. OCTs showed the overlying retina at full thickness for the first 2 days after implantation. Histology confirmed intact inner layers of the overlying retina until day 3. Progressive atrophy of the overlying retina was revealed by repeated OCTs; approximately 40% of the retina thickness remained on postoperative days 5 and 6. Conclusions The two-step implantation technique works well for the rabbit eye model with human prostheses. Rabbit retina may be used for acute electrophysiologic testing of a retinal prosthesis, but is unsuitable for chronic studies due to the merangiotic retina and its limited time window of validity. Translational Relevance The improved efficacy in prosthesis surgery using this technique will circumvent the challenges in animal models that provide human-like features critical for the transition into human clinical trials.
Collapse
Affiliation(s)
- Ying Xiao
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Yuqin Wang
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Fangting Li
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Tiezhu Lin
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Kristyn Huffman
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Stephanie Landeros
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | | | - Yi Jing
- Nanovision Biosciences, Inc., La Jolla, CA, USA
| | - Dirk-Uwe Bartsch
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | | | - William R Freeman
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Lingyun Cheng
- Department of Ophthalmology, Jacobs Retina Center at Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| |
Collapse
|
8
|
Zeng Q, Zhao S, Yang H, Zhang Y, Wu T. Micro/Nano Technologies for High-Density Retinal Implant. MICROMACHINES 2019; 10:E419. [PMID: 31234507 PMCID: PMC6630275 DOI: 10.3390/mi10060419] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 06/14/2019] [Accepted: 06/21/2019] [Indexed: 01/10/2023]
Abstract
During the past decades, there have been leaps in the development of micro/nano retinal implant technologies, which is one of the emerging applications in neural interfaces to restore vision. However, higher feedthroughs within a limited space are needed for more complex electronic systems and precise neural modulations. Active implantable medical electronics are required to have good electrical and mechanical properties, such as being small, light, and biocompatible, and with low power consumption and minimal immunological reactions during long-term implantation. For this purpose, high-density implantable packaging and flexible microelectrode arrays (fMEAs) as well as high-performance coating materials for retinal stimulation are crucial to achieve high resolution. In this review, we mainly focus on the considerations of the high-feedthrough encapsulation of implantable biomedical components to prolong working life, and fMEAs for different implant sites to deliver electrical stimulation to targeted retinal neuron cells. In addition, the functional electrode materials to achieve superior stimulation efficiency are also reviewed. The existing challenge and future research directions of micro/nano technologies for retinal implant are briefly discussed at the end of the review.
Collapse
Affiliation(s)
- Qi Zeng
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| | - Saisai Zhao
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| | - Hangao Yang
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| | - Yi Zhang
- Shenzhen CAS-Envision Medical Technology Co. Ltd., Shenzhen 518100, China.
| | - Tianzhun Wu
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| |
Collapse
|
9
|
Bosse B, Damle S, Akinin A, Jing Y, Bartsch DU, Cheng L, Oesch N, Lo YH, Cauwenberghs G, Freeman WR. In Vivo Photovoltaic Performance of a Silicon Nanowire Photodiode-Based Retinal Prosthesis. Invest Ophthalmol Vis Sci 2019; 59:5885-5892. [PMID: 30550611 PMCID: PMC6295940 DOI: 10.1167/iovs.18-24554] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Purpose For more than 20 years, there has been an international, multidisciplinary effort to develop retinal prostheses to restore functional vision to patients blinded by retinal degeneration. We developed a novel subretinal prosthesis with 1512 optically addressed silicon nanowire photodiodes, which transduce incident light into an electrical stimulation of the remaining retinal circuitry. This study was conducted to evaluate the efficacy of optically driving the subretinal prosthesis to produce visual cortex activation via electrical stimulation of the retina. Methods We measured electrically evoked potential responses (EEPs) in rabbit visual cortex in response to illumination of the subretinal nanowire prosthesis with pulsed 852-nm infrared (IR) light. We compared the EEP responses to visually evoked potential responses (VEPs) to pulsed 532-nm visible light (positive control) and pulsed 852-nm IR light (negative control). Results Activating the devices with IR light produced EEP responses with a significantly higher trough-to-peak amplitude (54.17 ± 33.4 μV) than IR light alone (24.07 ± 22.1 μV) or background cortical activity (23.22 ± 17.2 μV). EEP latencies were significantly faster than focal VEP latencies. Focal VEPs produced significantly higher amplitudes (94.88 ± 43.3 μV) than EEPs. We also demonstrated how an electrode placed on the cornea can be used as a noninvasive method to monitor the function of the implant. Conclusions These results show that subretinal electrical stimulation with nanowire electrodes can elicit EEPs in the visual cortex, providing evidence for the viability of a subretinal nanowire prosthetic approach for vision restoration.
Collapse
Affiliation(s)
- Brandon Bosse
- Nanovision Biosciences, Inc., La Jolla, California, United States
| | - Samir Damle
- Department of Bioengineering, University of California, San Diego, California, United States
| | - Abraham Akinin
- Department of Bioengineering, University of California, San Diego, California, United States
| | - Yi Jing
- Nanovision Biosciences, Inc., La Jolla, California, United States
| | - Dirk-Uwe Bartsch
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California, San Diego, California, United States
| | - Lingyun Cheng
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California, San Diego, California, United States
| | - Nicholas Oesch
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California, San Diego, California, United States.,Department of Psychology, University of California, San Diego, California, United States
| | - Yu-Hwa Lo
- Department of Electrical and Computer Engineering, University of California, San Diego, California, United States
| | - Gert Cauwenberghs
- Department of Bioengineering, University of California, San Diego, California, United States
| | - William R Freeman
- Jacobs Retina Center at Shiley Eye Institute, Department of Ophthalmology, University of California, San Diego, California, United States
| |
Collapse
|
10
|
Bareket L, Barriga-Rivera A, Zapf MP, Lovell NH, Suaning GJ. Progress in artificial vision through suprachoroidal retinal implants. J Neural Eng 2018; 14:045002. [PMID: 28541930 DOI: 10.1088/1741-2552/aa6cbb] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Retinal implants have proven their ability to restore visual sensation to people with degenerative retinopathy, characterized by photoreceptor cell death and the retina's inability to sense light. Retinal bionics operate by electrically stimulating the surviving neurons in the retina, thus triggering the transfer of visual sensory information to the brain. Suprachoroidal implants were first investigated in Australia in the 1950s. In this approach, the neuromodulation hardware is positioned between the sclera and the choroid, thus providing significant surgical and safety benefits for patients, with the potential to maintain residual vision combined with the artificial input from the device. Here we review the latest advances and state of the art devices for suprachoroidal prostheses, highlight future technologies and discuss challenges and perspectives towards improved rehabilitation of vision.
Collapse
Affiliation(s)
- Lilach Bareket
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | | | | | | | | |
Collapse
|
11
|
Abstract
Retinitis pigmentosa and age-related macular degeneration are both incurable eye diseases that lead to blindness due to photoreceptor degeneration. Electrically stimulating the remaining intact nerve cells may generate some useful vision for patients afflicted with these diseases. Various types of retinal prostheses, sub- and epi-retinal electrode arrays, as well as subretinal microphotodiode arrays are considered from a materials and biocompatibility point of view. Other, more innovative approaches to restoring vision, such as microfluidic pumps and activated nanosystems that deliver neurotransmitters in a controlled way and photodynamic therapy are being developed. This article discusses materials aspects of retinal prostheses that are currently in use or under development.
Collapse
Affiliation(s)
- Carmen Scholz
- Department of Chemistry, University of Alabama in Huntsville 301 Sparkman Drive, MSB 333, Huntsville, AL 35899, USA,
| |
Collapse
|
12
|
Sweitzer R, Scholz C, Montezuma S, Rizzo JF. Evaluation of Subretinal Implants Coated with Amorphous Aluminum Oxide and Diamond-like Carbon. J BIOACT COMPAT POL 2016. [DOI: 10.1177/0883911506060202] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Retinal prostheses may be used to support patients suffering from age-related macular degeneration (AMD) or retinitis pigmentosa (RP). A hermetic encapsulation of the poly(imide) (PI)-based prosthesis is important in order to prevent the leakage of water and ions into the electric circuitry embedded in the poly(imide) matrix. The deposition of amorphous aluminum oxide (by sputtering) and diamond like carbon (by pulsed laser ablation) were made for applications in retinal prostheses. The thin films obtained were characterized for composition, thickness, adhesion and smoothness by scanning electron microscopy-energy dispersive spectroscopy, atomic force microscopy, profilometry and light microscopy. Biocompatibility was tested in vivo by implanting coated specimen subretinally in the eye of Yucatan pigs. While amorphous aluminum oxide is more readily deposited with sufficient adhesion quality, superior biocompatibility behavior was shown by diamond-like carbon. Amorphous aluminum oxide had more adverse effects and caused more severe damage to the retinal tissue.
Collapse
Affiliation(s)
- Robyn Sweitzer
- Department of Chemistry, University of Alabama in Huntsville, Huntsville, AL 35899
| | - Carmen Scholz
- Department of Chemistry, University of Alabama in Huntsville, Huntsville, AL 35899, and VA Center for Innovative Visual Rehabilitation, Boston, MA
| | - Sandra Montezuma
- Department of Ophthalmology, Massachusetts Eye&Ear Infirmary, Boston, MA
| | - Joseph F. Rizzo
- Department of Ophthalmology, Massachusetts Eye&Ear Infirmary, Boston, MA and VA Center for Innovative Visual Rehabilitation, Boston, MA
| |
Collapse
|
13
|
Yue L, Weiland JD, Roska B, Humayun MS. Retinal stimulation strategies to restore vision: Fundamentals and systems. Prog Retin Eye Res 2016; 53:21-47. [DOI: 10.1016/j.preteyeres.2016.05.002] [Citation(s) in RCA: 173] [Impact Index Per Article: 21.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 05/13/2016] [Accepted: 05/21/2016] [Indexed: 11/28/2022]
|
14
|
Slater KD, Sinclair NC, Nelson TS, Blamey PJ, McDermott HJ. neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE-JTEHM 2015; 3:3800111. [PMID: 27170910 PMCID: PMC4848081 DOI: 10.1109/jtehm.2015.2455507] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2014] [Revised: 03/26/2015] [Accepted: 07/02/2015] [Indexed: 11/10/2022]
Abstract
To evaluate the efficacy of a suprachoroidal retinal prosthesis, a highly configurable external neurostimulator is required. In order to meet functional and safety specifications, it was necessary to develop a custom device. A system is presented which can deliver charge-balanced, constant-current biphasic pulses, with widely adjustable parameters, to arbitrary configurations of output electrodes. This system is shown to be effective in eliciting visual percepts in a patient with approximately 20 years of light perception vision only due to retinitis pigmentosa, using an electrode array implanted in the suprachoroidal space of the eye. The flexibility of the system also makes it suitable for use in a number of other emerging clinical neurostimulation applications, including epileptic seizure suppression and closed-loop deep brain stimulation. Clinical trial registration number NCT01603576 (www.clinicaltrials.gov).
Collapse
|
15
|
Yan Y, Sui X, Liu W, Lu Y, Cao P, Ma Z, Chen Y, Chai X, Li L. Spatial characteristics of evoked potentials elicited by a MEMS microelectrode array for suprachoroidal-transretinal stimulation in a rabbit. Graefes Arch Clin Exp Ophthalmol 2015; 253:1515-28. [PMID: 25981117 DOI: 10.1007/s00417-015-3027-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Revised: 03/26/2015] [Accepted: 04/20/2015] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Suprachoroidal-transretinal stimulation (STS) can potentially restore vision. This study investigated the spatial characteristics of cortical electrical evoked potentials (EEPs) elicited by STS. METHODS A 4 × 4 thin-film platinum microelectrode stimulating array (200 μm electrode diameter and 400 μm center-to-center distance) was fabricated by a micro-electro-mechanical systems (MEMS) techniques and implanted into the suprachoroidal space of albino rabbits. RESULTS The current threshold to elicit reliable EEPs by a single electrode was 41.6 ± 12.6 μA, corresponding to a 66.2 ± 20.1 μC · cm(-2) charge density per phase, which was lower than the reported safety limits. Spatially differentiated cortical responses could be evoked by STS through different rows or columns of electrical stimulation; furthermore, shifts in the location of the maximum cortical activities were consistent with cortical visuotopic maps; increasing the number of simultaneously stimulating electrodes increased the response amplitudes of EEPs and expanded the spatial spread as well. In addition, long-term implantation and electrical stimulation of the MEMS electrode array in suprachoroidal space are necessary to evaluate systematically the safety and biocompatibility of this approach. CONCLUSIONS This study indicates that the STS approach by a MEMS-based platinum electrode array is a feasible alternative for visual restoration, and relatively high spatial discrimination may be achieved.
Collapse
Affiliation(s)
- Yan Yan
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China,
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Light JG, Fransen JW, Adekunle AN, Adkins A, Pangeni G, Loudin J, Mathieson K, Palanker DV, McCall MA, Pardue MT. Inner retinal preservation in rat models of retinal degeneration implanted with subretinal photovoltaic arrays. Exp Eye Res 2014; 128:34-42. [PMID: 25224340 DOI: 10.1016/j.exer.2014.09.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 09/09/2014] [Accepted: 09/11/2014] [Indexed: 11/26/2022]
Abstract
Photovoltaic arrays (PVA) implanted into the subretinal space of patients with retinitis pigmentosa (RP) are designed to electrically stimulate the remaining inner retinal circuitry in response to incident light, thereby recreating a visual signal when photoreceptor function declines or is lost. Preservation of inner retinal circuitry is critical to the fidelity of this transmitted signal to ganglion cells and beyond to higher visual targets. Post-implantation loss of retinal interneurons or excessive glial scarring could diminish and/or eliminate PVA-evoked signal transmission. As such, assessing the morphology of the inner retina in RP animal models with subretinal PVAs is an important step in defining biocompatibility and predicting success of signal transmission. In this study, we used immunohistochemical methods to qualitatively and quantitatively compare inner retinal morphology after the implantation of a PVA in two RP models: the Royal College of Surgeons (RCS) or transgenic S334ter-line 3 (S334ter-3) rhodopsin mutant rat. Two PVA designs were compared. In the RCS rat, we implanted devices in the subretinal space at 4 weeks of age and histologically examined them at 8 weeks of age and found inner retinal morphology preservation with both PVA devices. In the S334ter-3 rat, we implanted devices at 6-12 weeks of age and again, inner retinal morphology was generally preserved with either PVA design 16-26 weeks post-implantation. Specifically, the length of rod bipolar cells and numbers of cholinergic amacrine cells were maintained along with their characteristic inner plexiform lamination patterns. Throughout the implanted retinas we found nonspecific glial reaction, but none showed additional glial scarring at the implant site. Our results indicate that subretinally implanted PVAs are well-tolerated in rodent RP models and that the inner retinal circuitry is preserved, consistent with our published results showing implant-evoked signal transmission.
Collapse
Affiliation(s)
- Jacob G Light
- Ophthalmology, Emory University, USA; Rehab R&D Center of Excellence, Atlanta VA Medical Center, USA
| | - James W Fransen
- Anatomical Sciences & Neurobiology, University of Louisville, USA
| | | | - Alice Adkins
- Rehab R&D Center of Excellence, Atlanta VA Medical Center, USA
| | - Gobinda Pangeni
- Ophthalmology & Visual Sciences, University of Louisville, USA
| | - James Loudin
- Hansen Experimental Physics Laboratory, Stanford University, USA
| | - Keith Mathieson
- Hansen Experimental Physics Laboratory, Stanford University, USA; Institute of Photonics, University of Strathclyde, UK
| | - Daniel V Palanker
- Hansen Experimental Physics Laboratory, Stanford University, USA; Ophthalmology, Stanford University, USA
| | - Maureen A McCall
- Anatomical Sciences & Neurobiology, University of Louisville, USA; Ophthalmology & Visual Sciences, University of Louisville, USA
| | - Machelle T Pardue
- Ophthalmology, Emory University, USA; Rehab R&D Center of Excellence, Atlanta VA Medical Center, USA.
| |
Collapse
|
17
|
Villalobos J, Fallon JB, Nayagam DAX, Shivdasani MN, Luu CD, Allen PJ, Shepherd RK, Williams CE. Cortical activation following chronic passive implantation of a wide-field suprachoroidal retinal prosthesis. J Neural Eng 2014; 11:046017. [PMID: 24965866 DOI: 10.1088/1741-2560/11/4/046017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The research goal is to develop a wide-field retinal stimulating array for prosthetic vision. This study aimed at evaluating the efficacy of a suprachoroidal electrode array in evoking visual cortex activity after long term implantation. APPROACH A planar silicone based electrode array (8 mm × 19 mm) was implanted into the suprachoroidal space in cats (ntotal = 10). It consisted of 20 platinum stimulating electrodes (600 μm diameter) and a trans-scleral cable terminated in a subcutaneous connector. Three months after implantation (nchronic = 6), or immediately after implantation (nacute = 4), an electrophysiological study was performed. Electrode total impedance was measured from voltage transients using 500 μs, 1 mA pulses. Electrically evoked potentials (EEPs) and multi-unit activity were recorded from the visual cortex in response to monopolar retinal stimulation. Dynamic range and cortical activation spread were calculated from the multi-unit recordings. MAIN RESULTS The mean electrode total impedance in vivo following 3 months was 12.5 ± 0.3 kΩ. EEPs were recorded for 98% of the electrodes. The median evoked potential threshold was 150 nC (charge density 53 μC cm(-2)). The lowest stimulation thresholds were found proximal to the area centralis. Mean thresholds from multiunit activity were lower for chronic (181 ± 14 nC) compared to acute (322 ± 20 nC) electrodes (P < 0.001), but there was no difference in dynamic range or cortical activation spread. SIGNIFICANCE Suprachoroidal stimulation threshold was lower in chronic than acute implantation and was within safe charge limits for platinum. Electrode-tissue impedance following chronic implantation was higher, indicating the need for sufficient compliance voltage (e.g. 12.8 V for mean impedance, threshold and dynamic range). The wide-field suprachoroidal array reliably activated the retina after chronic implantation.
Collapse
|
18
|
Penetrating electrode stimulation of the rabbit optic nerve: parameters and effects on evoked cortical potentials. Graefes Arch Clin Exp Ophthalmol 2013; 251:2545-54. [PMID: 24013577 DOI: 10.1007/s00417-013-2449-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2012] [Revised: 05/13/2013] [Accepted: 08/16/2013] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND Stimulus parameters, in particular pulse shape, are an important consideration in the application of electrical stimulation when experimentally testing a visual prosthesis. We changed the biphasic pulse shape of several asymmetric charge-balanced pulses to investigate their effect on optic nerve (ON) stimulation and the recorded cortical response. METHODS Monopolar platinum-iridium electrodes were implanted into the rabbit's ON behind the eyeball. Electrical evoked potentials (EEPs) were recorded with silver ball electrodes placed on the cortex, and the results quantified. RESULTS Our results indicate that changing the shape of cathodic-first charge-balanced biphasic pulse (CA) while maintaining charge balance could reduce the current thresholds for stimulation. When stimulated at the same charge density, the stimulus having high-amplitude short-duration (HASD) cathodic phase produced a higher amplitude response, with a larger spatial spread but with a lower current threshold compared with other stimuli. Adding an inter-phase gap between the two phases of the stimulus increased the EEP amplitude, but was saturated at a gap of ∼0.2 ms; this was most obvious with CA stimulation, which was able to elicit a larger cortical response than that elicited by asymmetrical charge-balanced stimulus pulses with HASD cathodic phase, in contrast to CA without a gap. As the stimulating frequency increased, the amplitudes of the EEP components elicited by CA monotonically decreased. The fastest component (P0) was present with stimulating frequencies as high as 80 Hz, while the slower P1 and P2 disappeared with stimulating frequencies higher than 40 and 20 Hz, respectively. CONCLUSION A CA stimulus waveform with an inter-phase gap of 0.2 ms was more efficacious for ON stimulation than other stimulus combinations, and therefore should result in less tissue damage, minimal electrode etching, and lower power consumption if used in a visual prosthesis.
Collapse
|
19
|
John SE, Shivdasani MN, Williams CE, Morley JW, Shepherd RK, Rathbone GD, Fallon JB. Suprachoroidal electrical stimulation: effects of stimulus pulse parameters on visual cortical responses. J Neural Eng 2013; 10:056011. [DOI: 10.1088/1741-2560/10/5/056011] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
20
|
Stronks HC, Barry MP, Dagnelie G. Electrically elicited visual evoked potentials in Argus II retinal implant wearers. Invest Ophthalmol Vis Sci 2013; 54:3891-901. [PMID: 23611993 DOI: 10.1167/iovs.13-11594] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE We characterized electrically elicited visual evoked potentials (eVEPs) in Argus II retinal implant wearers. METHODS eVEPs were recorded in four subjects, and analyzed by determining amplitude and latency of the first two positive peaks (P1 and P2). Subjects provided subjective feedback by rating the brightness and size of the phosphenes. We established eVEP input-output relationships, eVEP variability between and within subjects, the effect of stimulating different areas of the retina, and the maximal pulse rate to record eVEPs reliably. RESULTS eVEP waveforms had low signal-to-noise ratios, requiring long recording times and substantial signal processing. Waveforms varied between subjects, but showed good reproducibility and consistent parameter dependence within subjects. P2 amplitude overall was the most robust outcome measure and proved an accurate indicator of subjective threshold. Peak latencies showed small within-subject variability, yet their correlation with stimulus level and subjective rating were more variable than that of peak amplitudes. Pulse rates of up to (2)/3 Hz resulted in reliable eVEP recordings. Perceived phosphene brightness declined over time, as reflected in P1 amplitude, but not in P2 amplitude or peak latencies. Stimulating-electrode location significantly affected P1 and P2 amplitude and latency, but not subjective percepts. CONCLUSIONS While recording times and signal processing are more demanding than for standard visually evoked potential (VEP) recordings, the eVEP has proven to be a reliable tool to verify retinal implant functionality. eVEPs correlated with various stimulus parameters and with perceptual ratings. In view of these findings, eVEPs may become an important tool in functional investigations of retinal prostheses. (ClinicalTrials.gov number NCT00407602.) Dutch Abstract.
Collapse
|
21
|
Eiber CD, Lovell NH, Suaning GJ. Attaining higher resolution visual prosthetics: a review of the factors and limitations. J Neural Eng 2013; 10:011002. [PMID: 23337266 DOI: 10.1088/1741-2560/10/1/011002] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Visual prosthetics is an expanding subfield of functional electrical stimulation which has gained increased interest recently in light of new advances in treatments and technology. These treatments and technology represent a major improvement over prior art, but are still subject to a host of limitations which are dependent on the manner in which one approaches the topic of visual prosthetics. These limitations pose new research challenges whose solutions are directly applicable to the well-being of blind individuals everywhere. In this review, we will outline and critically compare major current approaches to visual prosthetics, and in particular retinal prosthetics. Then, we will engage in an in-depth discussion of the limitations imposed by current technology, physics, and the underlying biology of the retina to highlight several of the challenges currently facing researchers.
Collapse
Affiliation(s)
- Calvin D Eiber
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| | | | | |
Collapse
|
22
|
O'Brien EE, Greferath U, Vessey KA, Jobling AI, Fletcher EL. Electronic restoration of vision in those with photoreceptor degenerations. Clin Exp Optom 2012; 95:473-83. [PMID: 22823954 DOI: 10.1111/j.1444-0938.2012.00783.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2011] [Revised: 06/06/2012] [Accepted: 06/11/2012] [Indexed: 11/27/2022] Open
Abstract
Complete loss of vision is one of the most feared sequelae of retinal disease. Currently, there are few if any treatment options available to patients that may slow or prevent blindness in diseases caused by photoreceptor loss, such as retinitis pigmentosa and age-related macular degeneration. Electronic restoration of vision has emerged over recent years as a safe and viable option for those who have lost substantial numbers of photoreceptors and who are severely vision impaired. Indeed, there has been a dramatic increase in our understanding of what is required to restore vision using an electronic retinal prosthesis. Recent reports show that for some patients, restoration of vision to the point of reading large letters is possible. In this review, we examine the types of implants currently under investigation and the results these devices have achieved clinically. We then consider a range of engineering and biological factors that may need to be considered to improve the visual performance of newer-generation devices. With added research, it is hoped that the level of vision achieved with newer generation devices will steadily improve, resulting in enhanced quality of life for those with severe vision impairment.
Collapse
Affiliation(s)
- Emily E O'Brien
- Department of Anatomy and Cell Biology, The University of Melbourne, Parkville, Victoria, Australia.
| | | | | | | | | |
Collapse
|
23
|
Woo SJ, Kim SJ, Zhou JA, Kim ET, Seo JM, Park JH, Kim YK, Lee JS, Kim SJ, Chung H. Imaging of activated cortical areas after light and electrical stimulation of the rabbit retina: F-18 FDG PET-guided brain mapping. Biomed Eng Lett 2012. [DOI: 10.1007/s13534-012-0060-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
24
|
Cicione R, Shivdasani MN, Fallon JB, Luu CD, Allen PJ, Rathbone GD, Shepherd RK, Williams CE. Visual cortex responses to suprachoroidal electrical stimulation of the retina: effects of electrode return configuration. J Neural Eng 2012; 9:036009. [PMID: 22595310 DOI: 10.1088/1741-2560/9/3/036009] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A clinically effective retinal prosthesis must evoke localized phosphenes in a retinotopic manner in response to stimulation of each of the retinal electrodes, evoke brightness cues over a wide dynamic range and function within safe stimulus limits. The effects of varying return configuration for retinal stimulation are currently unknown. To investigate this, we implanted a flexible, 7 × 12 electrode array into the suprachoroidal space of normally-sighted, anesthetized cats. Multi-unit activity in the primary visual cortex was recorded in response to electrical stimulation using various return configurations: monopolar vitreous (MPV), common ground (CG), hexagonal (HX), monopolar remote (MPR) and bipolar (BP_N). MPV stimulation was found to be the most charge efficient and was most likely to induce cortical activity within safe charge limits. HX and CG stimulation were found to exhibit greater retinal selectivity compared to the MPV return at the expense of lower cortical yield and higher P50 charge levels, while cortical selectivity was unaffected by choice of return. Responses using MPR and widely spaced BP_N configurations were similar to those using the MPV return. These results suggest that choice of return configuration for a retinal prosthesis will be balanced between resolution and stimulation within safe charge limits.
Collapse
|
25
|
Loudin JD, Cogan SF, Mathieson K, Sher A, Palanker DV. Photodiode circuits for retinal prostheses. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2011; 5:468-80. [PMID: 23852178 PMCID: PMC7453407 DOI: 10.1109/tbcas.2011.2144980] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Photodiode circuits show promise for the development of high-resolution retinal prostheses. While several of these systems have been constructed and some even implanted in humans, existing descriptions of the complex optoelectronic interaction between light, photodiode, and the electrode/electrolyte load are limited. This study examines this interaction in depth with theoretical calculations and experimental measurements. Actively biased photoconductive and passive photovoltaic circuits are investigated, with the photovoltaic circuits consisting of one or more diodes connected in series, and the photoconductive circuits consisting of a single diode in series with a pulsed bias voltage. Circuit behavior and charge injection levels were markedly different for platinum and sputtered iridium-oxide film (SIROF) electrodes. Photovoltaic circuits were able to deliver 0.038 mC/cm(2) (0.75 nC/phase) per photodiode with 50- μm platinum electrodes, and 0.54-mC/cm(2) (11 nC/phase) per photodiode with 50-μ m SIROF electrodes driven with 0.5-ms pulses of light at 25 Hz. The same pulses applied to photoconductive circuits with the same electrodes were able to deliver charge injections as high as 0.38 and 7.6 mC/cm(2) (7.5 and 150 nC/phase), respectively. We demonstrate photovoltaic stimulation of rabbit retina in-vitro, with 0.5-ms pulses of 905-nm light using peak irradiance of 1 mW/mm(2). Based on the experimental data, we derive electrochemical and optical safety limits for pixel density and charge injection in various circuits. While photoconductive circuits offer smaller pixels, photovoltaic systems do not require an external bias voltage. Both classes of circuits show promise for the development of high-resolution optoelectronic retinal prostheses.
Collapse
|
26
|
Development of a surgical approach for a wide-view suprachoroidal retinal prosthesis: evaluation of implantation trauma. Graefes Arch Clin Exp Ophthalmol 2011; 250:399-407. [PMID: 21874343 DOI: 10.1007/s00417-011-1794-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2010] [Revised: 07/12/2011] [Accepted: 07/28/2011] [Indexed: 10/17/2022] Open
Abstract
BACKGROUND Our research goal is to develop a safe, reproducible surgical approach for implantation of a wide-field retinal stimulating array. The aim of this study was to evaluate the pathological response to acute implantation of a functional prototype electrode array in the suprachoroidal space. METHODS The surgical techniques to implant a 72 platinum electrode array fabricated on 8 × 13 × 0.4 mm polyimide and silicone substrate were developed in a pilot study in anesthetized cats. For the main study, nine eyes were implanted in vivo and unoperated eyes were used as controls. Surgery consisted of a temporal approach with a full-thickness scleral incision 5 mm posterior to the limbus. A suprachoroidal "pocket" was created, the electrode array inserted to sit beneath the area centralis, and placement was confirmed visually. The eyes were collected subsequently for histopathology. RESULTS The array was consistently inserted into the suprachoroidal space beneath the area centralis in nine eyes. There was a significant hemorrhage in two cases where implantation was complicated by choroidal congestion. Retinal folding occurred only when the array tip was within 2.6 mm of the optic disc (p < 0.01). There was choroidal incarceration at the incision in six eyes and scleral distortion at the array edges in five. No cases were found where the implant breached the retina, choroid, or sclera. CONCLUSIONS A large stimulation array can be reliably inserted into the suprachoroidal space without trauma to the neuroretina. These findings suggest that this is an appropriate surgical approach for the placement of an electrode array for use in retinal stimulation.
Collapse
|
27
|
Monopolar vs. bipolar subretinal stimulation—An in vitro study. J Neurosci Methods 2011; 199:26-34. [DOI: 10.1016/j.jneumeth.2011.04.017] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2010] [Revised: 03/24/2011] [Accepted: 04/14/2011] [Indexed: 11/23/2022]
|
28
|
Repeated transchoroidal implantation and explantation of compound subretinal prostheses: An exploratory study in rabbits. Jpn J Ophthalmol 2010; 54:467-75. [DOI: 10.1007/s10384-010-0851-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Accepted: 05/31/2010] [Indexed: 10/18/2022]
|
29
|
Yin S, Lovell NH, Suaning GJ, Dokos S. A continuum model of the retinal network and its response to electrical stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2010:2077-2080. [PMID: 21095947 DOI: 10.1109/iembs.2010.5626300] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A continuum network model of the retina is presented, consisting of an active implementation of the retinal ganglion cell tissue layer and passive implementation of deeper cell layers. The retinal ganglion cell layer receives excitatory presynaptic inputs from the bipolar layer and inhibitory presynaptic inputs from the amacrine layer. Simulations were performed to investigate the behavior of retinal tissue activation with epiretinal and suprachoroidal electrode stimulation. The results indicated the presence of both early and late onset action potentials consistent with experimental findings.
Collapse
Affiliation(s)
- Shijie Yin
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, 2052, Australia
| | | | | | | |
Collapse
|
30
|
|
31
|
Elfar SD, Cottaris NP, Iezzi R, Abrams GW. A cortical (V1) neurophysiological recording model for assessing the efficacy of retinal visual prostheses. J Neurosci Methods 2009; 180:195-207. [DOI: 10.1016/j.jneumeth.2009.02.019] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2007] [Revised: 02/25/2009] [Accepted: 02/25/2009] [Indexed: 10/21/2022]
|
32
|
Wong Y, Chen S, Seo J, Morley J, Lovell N, Suaning G. Focal activation of the feline retina via a suprachoroidal electrode array. Vision Res 2009; 49:825-33. [DOI: 10.1016/j.visres.2009.02.018] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2008] [Revised: 02/17/2009] [Accepted: 02/26/2009] [Indexed: 11/25/2022]
|
33
|
Shire DB, Kelly SK, Chen J, Doyle P, Gingerich MD, Cogan SF, Drohan WA, Mendoza O, Theogarajan L, Wyatt JL, Rizzo JF. Development and implantation of a minimally invasive wireless subretinal neurostimulator. IEEE Trans Biomed Eng 2009; 56:2502-11. [PMID: 19403357 DOI: 10.1109/tbme.2009.2021401] [Citation(s) in RCA: 120] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A wirelessly operated, minimally invasive retinal prosthesis was developed for preclinical chronic implantation studies in Yucatan minipig models. The implant conforms to the outer wall of the eye and drives a microfabricated polyimide stimulating electrode array with sputtered iridium oxide electrodes. This array is implanted in the subretinal space using a specially designed ab externo surgical technique that fixes the bulk of the prosthesis to the outer surface of the sclera. The implanted device is fabricated on a host polyimide flexible circuit. It consists of a 15-channel stimulator chip, secondary power and data receiving coils, and discrete power supply components. The completed device is encapsulated in poly(dimethylsiloxane) except for the reference/counter electrode and the thin electrode array. In vitro testing was performed to verify the performance of the system in biological saline using a custom RF transmitter circuit and primary coils. Stimulation patterns as well as pulse strength, duration, and frequency were programmed wirelessly using custom software and a graphical user interface. Wireless operation of the retinal implant has been verified both in vitro and in vivo in three pigs for more than seven months, the latter by measuring stimulus artifacts on the eye surface using contact lens electrodes.
Collapse
Affiliation(s)
- Douglas B Shire
- Veterans Affairs (VA) Center for Innovative Visual Rehabilitation, VA Boston Healthcare System, Boston, MA 02130, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Cottaris NP, Elfar SD. Assessing the efficacy of visual prostheses by decoding ms-LFPs: application to retinal implants. J Neural Eng 2009; 6:026007. [DOI: 10.1088/1741-2560/6/2/026007] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
|
36
|
Siu TL, Morley JW. Suppression of visual cortical evoked responses following deprivation of pattern vision in adult mice. Eur J Neurosci 2008; 28:484-90. [PMID: 18702720 DOI: 10.1111/j.1460-9568.2008.06342.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The effect of visual loss on the adult neocortex can have significant impact on the success of a visual implant. Recent research has shown that the adult neocortex retains substantial plasticity following a disruption to its afferent input. The result of these changes may hamper the development of a visual prosthesis if visual sensation cannot be effectively restored by stimulation of the surviving elements of the visual pathway. In order to evaluate further the visual performance of the mammalian adult brain following visual loss, especially the dominant form of blindness in humans, namely loss of pattern vision, we examined the cortical evoked potential of adult mice following 7, 30 and 120 days of visual deprivation via bilateral eyelid suture. Cortical potentials were elicited with a flash visual stimulus or by electrical stimulation of the retina. We found that after 7 days deprivation there was a potentiation of the evoked response while at 30 and 120 days deprivation the visual evoked responses were significantly reduced. Increasing the visual stimulus intensity reduced the effects. The electrical evoked potential demonstrated a corresponding reduction in stimulus threshold at 7 days and a corresponding rise (40-50%) after 30 and 120 days. These findings suggest that the adult brain exhibited significant experience-dependent modifications following visual loss, and the impact depended on the duration of deprivation. Such reduction in visual responsiveness, especially with electrical activation, will need to be taken into account in the development of a visual implant.
Collapse
Affiliation(s)
- Timothy L Siu
- School of Medical Sciences, University of New South Wales, Sydney, NSW, Australia.
| | | |
Collapse
|
37
|
Bošnjak R, Benedièiè M. Direct epidural electrical stimulation of the optic nerve: a new method for intraoperative assessment of function. J Neurosurg 2008; 109:647-53. [DOI: 10.3171/jns/2008/109/10/0647] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Intraoperative visual system monitoring of lesions with a close relationship to the optic apparatus by using light flashes reportedly is difficult to perform, and the results are too unreliable to interpret. The authors used direct epidural electrical stimulation of the optic nerve (ON) during surgery instead of light flashes.
Four patients were included in this feasibility study. In 3 patients—1 each harboring a planum sphenoidale meningioma, a tuberculum sellae meningioma, and an intraorbital ON sheath meningioma—2 stimulating needle electrodes were placed on each side of the ON just anterior to the optic canal, before unroofing the optic canal and an extradural anterior clinoidectomy. In the fourth patient, who harbored a frontotemporal astrocytoma, stimulation was applied at the exit of the ON from the canal. The electrically induced visual evoked potentials (eVEPs) were recorded from the scalp before, during, and after tumor removal.
A typical eVEP consisted of N20 and N40 waves. The amplitude of the N40 wave varied up to 25% prior to tumor removal. In the patient with a symptomatic tuberculum sellae meningioma, the decompressive effect of opening the optic canal and the impact of manipulation during piecemeal tumor removal were detected by the eVEPs. In the patient with an ON sheath meningioma and light sensation, only the N20 wave was observed.
Epidural electrical stimulation of the ON is a safe means of providing a stable signal and real-time information on nerve conduction during surgery. It may be a useful adjunct in improving visual outcomes postoperatively. Further clinical studies are necessary.
Collapse
|
38
|
A review of in vivo animal studies in retinal prosthesis research. Graefes Arch Clin Exp Ophthalmol 2008; 246:1505-17. [PMID: 18709385 DOI: 10.1007/s00417-008-0891-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2008] [Revised: 06/12/2008] [Accepted: 06/16/2008] [Indexed: 01/09/2023] Open
Abstract
BACKGROUND The development of a functional retinal prosthesis for acquired blindness is a great challenge. Rapid progress in the field over the last 15 years would not have been possible without extensive animal experimentation pertaining to device design and fabrication, biocompatibility, stimulation parameters and functional responses. This paper presents an overview of in vivo animal research related to retinal prosthetics, and aims to summarize the relevant studies. METHODS A Pubmed search of the English language literature was performed. The key search terms were: retinal implant, retinal prosthesis, artificial vision, rat, rabbit, cat, dog, sheep, pig, minipig. In addition a manual search was performed based on references quoted in the articles retrieved through Pubmed. RESULTS We identified 50 articles relevant to in vivo animal experimentation directly related to the development of a retinal implant. The highest number of publications related to the cat (n = 18). CONCLUSION The contribution of animal models to the development of retinal prosthetic devices has been enormous, and has led to human feasibility studies. Grey areas remain regarding long-term tissue-implant interactions, biomaterials, prosthesis design and neural adaptation. Animals will continue to play a key role in this rapidly evolving field.
Collapse
|
39
|
Implantation of episcleral electrodes via anterior orbitotomy for stimulation of the retina with induced photoreceptor degeneration: an in vivo feasibility study on a conceptual visual prosthesis. Acta Neurochir (Wien) 2008; 150:477-85; discussion 485. [PMID: 18385925 DOI: 10.1007/s00701-008-1528-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2007] [Accepted: 01/08/2008] [Indexed: 10/22/2022]
Abstract
BACKGROUND A visual prosthesis is a conceptual device designed to harnesses the function of residual afferent neurons in the visual pathway to produce artificial vision. Such implant, when applied to stimulate the vitreous surface of the retina, has proven feasible in producing the perception of light in both animals and humans. However the practicality of such device has been challenged by the difficulty of surgical access and the risks of damaging the neuroretina. Positioning a visual implant over the scleral surface of the eye could present a safer alternative but this stimulation modality has not been tested in diseased retinas and little is known about the altered electrophysiological properties of the retina in influencing the feasibility of such approach. METHODS Experimental photoreceptor degeneration was induced in four pigmented rabbit eyes with systematic administration of a retinotoxic agent, sodium iodate. A multielectrode array was implanted onto the surface of the sclera to target the central and peripheral parts of the retina via an anterior orbitotomy approach. The efficacy of retinal stimulation was assessed by recording electrical evoked potential over the primary visual cortex. FINDINGS The electrical evoked potentials were obtained from both injected and control eyes. The charge density thresholds were found to be similar in both groups and were below the bioelectric safety limit. Spatially differentiated cortical activation profiles were obtained from the central and peripheral retina and the pattern of activation corresponded to the retinotopography of the rabbit primary visual cortex. CONCLUSION This study proves that episcleral stimulation of the retina is a feasible alternative to intraocular approaches for the development of a visual prosthesis for retinas with photoreceptor loss.
Collapse
|
40
|
|
41
|
Zhou JA, Woo SJ, Park SI, Kim ET, Seo JM, Chung H, Kim SJ. A suprachoroidal electrical retinal stimulator design for long-term animal experiments and in vivo assessment of its feasibility and biocompatibility in rabbits. J Biomed Biotechnol 2008; 2008:547428. [PMID: 18317521 PMCID: PMC2246081 DOI: 10.1155/2008/547428] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2007] [Revised: 11/29/2007] [Accepted: 12/24/2007] [Indexed: 02/03/2023] Open
Abstract
This article reports on a retinal stimulation system for long-term use in animal electrical stimulation experiments. The presented system consisted of an implantable stimulator which provided continuous electrical stimulation, and an external component which provided preset stimulation patterns and power to the implanted stimulator via a paired radio frequency (RF) coil. A rechargeable internal battery and a parameter memory component were introduced to the implanted retinal stimulator. As a result, the external component was not necessary during the stimulation mode. The inductive coil pair was used to pass the parameter data and to recharge the battery. A switch circuit was used to separate the stimulation mode from the battery recharging mode. The implantable stimulator was implemented with IC chips and the electronics, except for the stimulation electrodes, were hermetically packaged in a biocompatible metal case. A polyimide-based gold electrode array was used. Surgical implantation into rabbits was performed to verify the functionality and safety of this newly designed system. The electrodes were implanted in the suprachoroidal space. Evoked cortical potentials were recorded during electrical stimulation of the retina. Long-term follow-up using OCT showed no chorioretinal abnormality after implantation of the electrodes.
Collapse
Affiliation(s)
- J. A. Zhou
- Nano Bioelectronics & Systems Research Center, Seoul National University, Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
- Nano Artificial Vision Research Center, Seoul National University Hospital,
Yeongeon-dong, Jongno-gu, Seoul 110-744, South Korea
- School of Electrical Engineering and Computer Science, Seoul National University,
Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
| | - S. J. Woo
- Nano Bioelectronics & Systems Research Center, Seoul National University, Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
- Nano Artificial Vision Research Center, Seoul National University Hospital,
Yeongeon-dong, Jongno-gu, Seoul 110-744, South Korea
- Department of Ophthalmology, Seoul National University College of Medicine,
Yeongeon-dong, Jongno-gu, Seoul 110-799, South Korea
- Seoul National University Bundang Hospital, Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707, South Korea
| | - S. I. Park
- Nano Bioelectronics & Systems Research Center, Seoul National University, Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
| | - E. T. Kim
- Nano Bioelectronics & Systems Research Center, Seoul National University, Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
- Nano Artificial Vision Research Center, Seoul National University Hospital,
Yeongeon-dong, Jongno-gu, Seoul 110-744, South Korea
- School of Electrical Engineering and Computer Science, Seoul National University,
Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
| | - J. M. Seo
- Nano Bioelectronics & Systems Research Center, Seoul National University, Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
- Nano Artificial Vision Research Center, Seoul National University Hospital,
Yeongeon-dong, Jongno-gu, Seoul 110-744, South Korea
- Department of Ophthalmology, Dongguk University College of Medicine, Pil-dong, Jung-gu, Seoul 100-715, South Korea
| | - H. Chung
- Nano Bioelectronics & Systems Research Center, Seoul National University, Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
- Nano Artificial Vision Research Center, Seoul National University Hospital,
Yeongeon-dong, Jongno-gu, Seoul 110-744, South Korea
- Department of Ophthalmology, Seoul National University College of Medicine,
Yeongeon-dong, Jongno-gu, Seoul 110-799, South Korea
| | - S. J. Kim
- Nano Bioelectronics & Systems Research Center, Seoul National University, Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
- Nano Artificial Vision Research Center, Seoul National University Hospital,
Yeongeon-dong, Jongno-gu, Seoul 110-744, South Korea
- School of Electrical Engineering and Computer Science, Seoul National University,
Shillim-dong, Gwanak-gu, Seoul 151-742, South Korea
| |
Collapse
|
42
|
Winter JO, Cogan SF, Rizzo JF. Retinal prostheses: current challenges and future outlook. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2007; 18:1031-55. [PMID: 17705997 DOI: 10.1163/156856207781494403] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Blindness from retinal diseases, including age-related macular degeneration (AMD) and retinitis pigmentosa (RP), usually causes a significant decline in quality of life for affected patients. Currently there is no cure for these conditions. However, over the last decade, several groups have been developing retinal prostheses which hopefully will provide some degree of improved visual function to these patients. Several such devices are now in clinical trials. Unfortunately, the possibility of electrode or tissue damage limits excitation schemes to those that may be employed with electrodes that have relatively low charge densities. Further, the excitation thresholds that have been required to achieve vision to date, in general, are relatively high. This may result in part from poor apposition between neurons and the stimulating electrodes and is confounded by the effects of the photoreceptor loss, which initiates other pathology in the surviving retinal tissue. The combination of these and other factors imposes a restriction on the pixel density that can be used for devices that actively deliver electrical stimulation to the retina. The resultant use of devices with relatively low pixel densities presumably will limit the degree of visual resolution that can be obtained with these devices. Further increases in pixel density, and therefore increased visual acuity, will necessitate either improved electrode-tissue biocompatibility or lower stimulation thresholds. To meet this challenge, innovations in materials and devices have been proposed. Here, we review the types of retinal prostheses investigated, the extent of their current biocompatibility and future improvements designed to surmount these limitations.
Collapse
Affiliation(s)
- Jessica O Winter
- Center for Innovative Visual Rehabilitation, VA Medical Center, Boston, MA, USA.
| | | | | |
Collapse
|
43
|
Siu TL, Morley JW. Influence of callosal transfer on visual cortical evoked response and the implication in the development of a visual prosthesis. Graefes Arch Clin Exp Ophthalmol 2007; 245:1797-803. [PMID: 17638003 DOI: 10.1007/s00417-007-0648-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2007] [Revised: 06/19/2007] [Accepted: 06/23/2007] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The development of a visual prosthesis has been limited by an incomplete understanding of functional changes of the visual cortex accompanying deafferentation. In particular, the role of the corpus callosum in modulating these changes has not been fully evaluated. Recent experimental evidence suggests that through synaptic modulation, short-term (4-5 days) visual deafferentation can induce plastic changes in the visual cortex, leading to adaptive enhancement of residual visual input. We therefore investigated whether a compensatory rerouting of visual information can occur via the indirect transcallosal linkage after deafferentation and the influence of this interhemispheric communication on the visual evoked response of each hemisphere. METHODS In albino rabbits, misrouting of uncrossed optic fibres reduces ipsilateral input to a negligible degree. We thus took advantage of this congenital anomaly to model unilateral cortical and ocular deafferentation by eliminating visual input from one eye and recorded the visual evoked potential (VEP) from the intact eye. RESULTS In keeping with the chiasmal anomaly, no VEP was elicited from the hemisphere ipsilateral to the intact eye. This remained unchanged following unilateral visual deafferentation. The amplitude and latency of the VEP in the fellow hemisphere, however, were significantly decreased in the deafferented animals. CONCLUSION Our data suggest that callosal linkage does not contribute to visual evoked responses and this is not changed after short-term deafferentation. The decrease in amplitude and latency of evoked responses in the hemisphere ipsilateral to the treated eye, however, confirms the facilitatory role of callosal transfer. This observation highlights the importance of bicortical stimulation in the future design of a cortical visual prosthesis.
Collapse
Affiliation(s)
- Timothy L Siu
- Department of Neurosurgery, Prince of Wales Hospital, Barker Street, Randwick, NSW 2031, Australia.
| | | |
Collapse
|
44
|
Abstract
The design of effective visual prostheses for the blind represents a challenge for biomedical engineers and neuroscientists. Significant progress has been made in the miniaturization and processing power of prosthesis electronics; however development lags in the design and construction of effective machine-brain interfaces with visual system neurons. This review summarizes what has been learned about stimulating neurons in the human and primate retina, lateral geniculate nucleus and visual cortex. Each level of the visual system presents unique challenges for neural interface design. Blind patients with the retinal degenerative disease retinitis pigmentosa (RP) are a common population in clinical trials of visual prostheses. The visual performance abilities of normals and RP patients are compared. To generate pattern vision in blind patients, the visual prosthetic interface must effectively stimulate the retinotopically organized neurons in the central visual field to elicit patterned visual percepts. The development of more biologically compatible methods of stimulating visual system neurons is critical to the development of finer spatial percepts. Prosthesis electrode arrays need to adapt to different optimal stimulus locations, stimulus patterns, and patient disease states.
Collapse
Affiliation(s)
- Ethan D Cohen
- Division of Physics, Office of Science and Engineering Labs, Center for Devices and Radiological Health, HFZ130, 12725 Twinbrook Pkwy, Rockville, MD 20852, USA.
| |
Collapse
|
45
|
Abstract
The possibility of using retina implants ('retinal prostheses') for the restoration of basic orientation in blind patients suffering from distal retinal diseases is presently under investigation by at least 18 independent project groups worldwide. It is a common feature of all implants to bypass degenerated retinal layers and to transfer visual information into the retinal network either by direct electrical stimulation or by neurotransmitter release. Contemporary implant designs are differing in the position of stimulating electrodes (epiretinal, subretinal, external) and the anatomical arrangement of implant components (intraocular, extraocular). The latter is of high relevance with regard to possible implant-tissue interactions and biological reactions. During the last few years new types of implants appeared that reduce intraocular components which are now deposited on the outer scleral surface or even in extraorbital position. The extreme of this trend are completely extraocular implants with transchoroidal or extraocular stimulation of the retina. The new type of implant presented in this paper combines the principle of direct retinal stimulation and minimal invasive implantation in a way that stimulating electrodes are the only implant component penetrating the eye via sclera, choroid and retinal pigment epithelium. All other device elements are positioned in extraocular position. The new concept necessitates a paradigmatic change about surgical handling of the choroid and multiple penetrations of the eye. Successful data about this type of retinal prosthesis are already available from long-term observation in non-human primates.
Collapse
Affiliation(s)
- H Gerding
- Department of Retinology, Klinik Pallas, Olten, Switzerland.
| |
Collapse
|
46
|
Abstract
This report provides a brief overview of blinding eye diseases for which prosthetic vision may hold promise as a treatment modality, and of current and near-term technological approaches towards the creation of prosthetic interfaces with the remaining visual system. Principal anatomical, physiological, technological and functional obstacles and possible solutions are outlined, and references are provided to pioneering work by over a dozen groups on four continents.
Collapse
Affiliation(s)
- Gislin Dagnelie
- Ophthalmology, Johns Hopkins University School of Medicine, Lions Vision Research and Rehabilitation Center, Wilmer Ophthalmological Institute, Baltimore, MD 21205, USA.
| |
Collapse
|
47
|
Jensen RJ, Rizzo JF. Thresholds for activation of rabbit retinal ganglion cells with a subretinal electrode. Exp Eye Res 2006; 83:367-73. [PMID: 16616739 DOI: 10.1016/j.exer.2006.01.012] [Citation(s) in RCA: 98] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2005] [Revised: 12/20/2005] [Accepted: 01/02/2006] [Indexed: 11/22/2022]
Abstract
The ultimate success of a retinal prosthesis to create vision will likely depend upon developing a base of knowledge of how best to electrically stimulate the retina. Previously, we studied the responses of rabbit retinal ganglion cells (RGCs) to current pulses applied with an electrode placed on the epiretinal surface. In the present study, we examined the responses of rabbit RGCs to current pulses applied with a subretinal electrode. Single-unit extracellular recordings were made from OFF RGCs and ON RGCs in isolated retinas, which were stimulated with monophasic current pulses (0.1-50ms in duration), delivered through a 500-mum diameter electrode. All RGCs elicited one or more bursts of action potentials upon electrical stimulation of the retina. The timing of the bursts depended upon both the polarity of the electrical stimulus and the RGC type. With near-threshold current pulses, the response latencies of OFF RGCs to anodal stimulation were comparable to those of ON RGCs to cathodal stimulation, whereas the response latencies of OFF RGCs to cathodal stimulation were comparable to those of ON RGCs to anodal stimulation. Threshold currents for activation of RGCs decreased with increased pulse duration. For OFF RGCs, threshold currents for cathodal current pulses were, on average, 2-7.5 times higher (depending upon pulse duration) than the threshold currents for anodal current pulses. For ON RGCs, threshold currents for cathodal and anodal current pulses were, on average, nearly identical for all pulse durations and were equivalent to threshold currents of OFF RGCs to anodal stimulation. With respect to a subretinal prosthesis, our findings suggest the possibility that cathodal current pulses may bias activation of ON RGCs in blind patients.
Collapse
Affiliation(s)
- Ralph J Jensen
- Center for Innovative Visual Rehabilitation, VA Boston Healthcare System, 150 South Huntington Avenue, Mail Stop 151E, Boston, MA 02130, USA.
| | | |
Collapse
|