1
|
Lu S, Qian CS, Grueber WB. Mechanisms of gas sensing by internal sensory neurons in Drosophila larvae. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.01.20.576342. [PMID: 38293088 PMCID: PMC10827222 DOI: 10.1101/2024.01.20.576342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
Internal sensory neurons monitor the chemical and physical state of the body, providing critical information to the central nervous system for maintaining homeostasis and survival. A population of larval Drosophila sensory neurons, tracheal dendrite (td) neurons, elaborate dendrites along respiratory organs and may serve as a model for elucidating the cellular and molecular basis of chemosensation by internal neurons. We find that td neurons respond to decreases in O2 levels and increases in CO2 levels. We assessed the roles of atypical soluble guanylyl cyclases (Gycs) and a gustatory receptor (Gr) in mediating these responses. We found that Gyc88E/Gyc89Db were necessary for responses to hypoxia, and that Gr28b was necessary for responses to CO2. Targeted expression of Gr28b isoform c in td neurons rescued responses to CO2 in mutant larvae and also induced ectopic sensitivity to CO2 in the td network. Gas-sensitive td neurons were activated when larvae burrowed for a prolonged duration, demonstrating a natural-like feeding condition in which td neurons are activated. Together, our work identifies two gaseous stimuli that are detected by partially overlapping subsets of internal sensory neurons, and establishes roles for Gyc88E/Gyc89Db in the detection of hypoxia, and Gr28b in the detection of CO2.
Collapse
Affiliation(s)
- Shan Lu
- Zuckerman Mind Brain Behavior Institute, Jerome L. Greene Science Center, 3227 Broadway, L9-007, Columbia University, New York, NY 10027
- Department of Biological Sciences, Jerome L. Greene Science Center, 3227 Broadway, L9-007, Columbia University, New York, NY 10027
| | - Cheng Sam Qian
- Zuckerman Mind Brain Behavior Institute, Jerome L. Greene Science Center, 3227 Broadway, L9-007, Columbia University, New York, NY 10027
| | - Wesley B. Grueber
- Zuckerman Mind Brain Behavior Institute, Jerome L. Greene Science Center, 3227 Broadway, L9-007, Columbia University, New York, NY 10027
- Department of Physiology and Cellular Biophysics, Jerome L. Greene Science Center, 3227 Broadway, L9-007, Columbia University, New York, NY 10027
- Department of Neuroscience, Jerome L. Greene Science Center, 3227 Broadway, L9-007, Columbia University, New York, NY 10027
| |
Collapse
|
2
|
Luo SXL, Swager TM. Wireless Detection of Trace Ammonia: A Chronic Kidney Disease Biomarker. ACS NANO 2024; 18:364-372. [PMID: 38147595 DOI: 10.1021/acsnano.3c07325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2023]
Abstract
Elevated levels of ammonia in breath can be linked to medical complications, such as chronic kidney disease (CKD), that disturb the urea balance in the body. However, early stage CKD is usually asymptomatic, and mass screening is hindered by high instrumentation and operation requirements and accessible and reliable detection methods for CKD biomarkers, such as trace ammonia in breath. Enabling methods would have significance in population screening for early stage CKD patients. We herein report a method to effectively immobilize transition metal selectors in close proximity to a single-walled carbon nanotube (SWCNT) surface using pentiptycene polymers containing metal-chelating backbone structures. The robust and modular nature of the pentiptycene metallopolymer/SWCNT complexes creates a platform that accelerates sensor discovery and optimization. Using these methods, we have identified sensitive, selective, and robust copper-based chemiresistive ammonia sensors that display low parts per billion detection limits. We have added these hybrid materials to the resonant radio frequency circuits of commercial near-field communication (NFC) tags to achieve robust wireless detection of ammonia at physiologically relevant levels. The integrated devices offer a noninvasive and cost-effective approach for early detection and monitoring of CKD.
Collapse
Affiliation(s)
- Shao-Xiong Lennon Luo
- Department of Chemistry and Institute for Soldier Nanotechnologies, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Timothy M Swager
- Department of Chemistry and Institute for Soldier Nanotechnologies, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
3
|
Jiang J, Li ZW, Wu ZF, Huang XY. A Soluble Porous Coordination Polymer for Fluorescence Sensing of Explosives and Toxic Anions under Homogeneous Environment. SENSORS (BASEL, SWITZERLAND) 2023; 23:9719. [PMID: 38139565 PMCID: PMC10747015 DOI: 10.3390/s23249719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 12/05/2023] [Accepted: 12/06/2023] [Indexed: 12/24/2023]
Abstract
In the past decades, porous coordination polymers (PCPs) based fluorescent (FL) sensors have received intense attention due to their promising applications. In this work, a soluble Zn-PCP is presented as a sensitive probe towards explosive molecules, chromate, and dichromate ions. In former reports, PCP sensors were usually ground into fine powders and then dispersed in solvents to form FL emulsion for sensing applications. However, their insoluble characters would cause the sensing accuracy which is prone to interference from environmental effects. While in this work, the as-made PCP could be directly soluble in organic solvents to form a clear solution with bright blue emission, representing the first soluble PCP based fluorescence sensor to probe explosive molecules under a homogeneous environment. Moreover, the FL PCP solution also shows sensitive detection behaviors towards the toxic anions of CrO42- and Cr2O72-, which exhibit a good linear relationship between the fluorescence intensity of Zn-PCP and the concentrations of both analytes. This work provides a reference for designing task-specific PCP sensors utilized under a homogeneous environment.
Collapse
Affiliation(s)
- Jiang Jiang
- College of Life Sciences, Fujian Agriculture and Forestry University, Fuzhou 350002, China;
| | - Zi-Wei Li
- State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, The Chinese Academy of Sciences, Fuzhou 350002, China; (Z.-W.L.); (X.-Y.H.)
| | - Zhao-Feng Wu
- State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, The Chinese Academy of Sciences, Fuzhou 350002, China; (Z.-W.L.); (X.-Y.H.)
| | - Xiao-Ying Huang
- State Key Laboratory of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, The Chinese Academy of Sciences, Fuzhou 350002, China; (Z.-W.L.); (X.-Y.H.)
| |
Collapse
|
4
|
Bhogadia M, Edgar M, Hunwin K, Page G, Grootveld M. Detection and Quantification of Ammonia as the Ammonium Cation in Human Saliva by 1H NMR: A Promising Probe for Health Status Monitoring, with Special Reference to Cancer. Metabolites 2023; 13:792. [PMID: 37512499 PMCID: PMC10383521 DOI: 10.3390/metabo13070792] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 06/21/2023] [Accepted: 06/22/2023] [Indexed: 07/30/2023] Open
Abstract
Ammonia (NH3) has been shown to be a key biomarker for a wide variety of diseases, such as hepatic and chronic kidney diseases (CKD), and cancers. It also has relevance to the oral health research area, and, hence, its determination in appropriate biofluids and tissues is of much importance. However, since it contains exchangeable >N-H protons, its analysis via 1H NMR spectroscopy, which is a widely employed technique in untargeted metabolomic studies, is rendered complicated. In this study, we focused on the 1H NMR analysis of this biomarker in less invasively collected human saliva samples, and we successfully identified and quantified it as ammonium cation (NH4+) in post-collection acidulated forms of this biofluid using both the standard calibration curve and standard addition method (SAM) approaches. For this purpose, n = 27 whole mouth saliva (WMS) samples were provided by healthy human participants, and all donors were required to follow a fasting/oral environment abstention period of 8 h prior to collection. Following acidification (pH 2.00), diluted WMS supernatant samples treated with 10% (v/v) D2O underwent 1H NMR analysis (600 MHz). The acquired results demonstrated that NH4+ can be reliably determined in these supernatants via integration of the central line of its characteristic 1:1:1 intensity triplet resonance (complete spectral range δ = 6.97-7.21 ppm). Experiments performed also demonstrated that any urease-catalysed NH3 generation occurring post-sampling in WMS samples did not affect the results acquired during the usual timespan of laboratory processing required prior to analysis. Further experiments demonstrated that oral mouth-rinsing episodes conducted prior to sample collection, as reported in previous studies, gave rise to major decreases in salivary NH4+ levels thereafter, which renormalised to only 50-60% of their basal control concentrations at the 180-min post-rinsing time point. Therefore, the WMS sample collection method employed significantly affected the absolute levels of this analyte. The LLOD was 60 μmol/L with 128 scans. The mean ± SD salivary NH4+ concentration of WMS supernatants was 11.4 ± 4.5 mmol/L. The potential extension of these analytical strategies to the screening of other metabolites with exchangeable 1H nuclei is discussed, as is their relevance to the monitoring of human disorders involving the excessive generation and/or uptake of cellular/tissue material, or altered homeostasis, in NH3.
Collapse
Affiliation(s)
- Mohammed Bhogadia
- Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK
| | - Mark Edgar
- Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK
| | - Kayleigh Hunwin
- Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK
| | - Georgina Page
- Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK
| | - Martin Grootveld
- Leicester School of Pharmacy, De Montfort University, The Gateway, Leicester LE1 9BH, UK
| |
Collapse
|
5
|
Kalidoss R, Umapathy S, Rani Thirunavukkarasu U. A breathalyzer for the assessment of chronic kidney disease patients’ breathprint: Breath flow dynamic simulation on the measurement chamber and experimental investigation. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.103060] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
6
|
Comprehensive Two-Dimensional Gas Chromatography-Mass Spectrometry Analysis of Exhaled Breath Compounds after Whole Grain Diets. Molecules 2021; 26:molecules26092667. [PMID: 34063191 PMCID: PMC8125105 DOI: 10.3390/molecules26092667] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 04/26/2021] [Accepted: 04/30/2021] [Indexed: 12/18/2022] Open
Abstract
Exhaled breath is a potential noninvasive matrix to give new information about metabolic effects of diets. In this pilot study, non-targeted analysis of exhaled breath volatile organic compounds (VOCs) was made by comprehensive two-dimensional gas chromatography-mass spectrometry (GCxGC-MS) to explore compounds relating to whole grain (WG) diets. Nine healthy subjects participated in the dietary intervention with parallel crossover design, consisting of two high-fiber diets containing whole grain rye bread (WGR) or whole grain wheat bread (WGW) and 1-week control diets with refined wheat bread (WW) before both diet periods. Large interindividual differences were detected in the VOC composition. About 260 VOCs were detected from exhaled breath samples, in which 40 of the compounds were present in more than half of the samples. Various derivatives of benzoic acid and phenolic compounds, as well as some furanones existed in exhaled breath samples only after the WG diets, making them interesting compounds to study further.
Collapse
|
7
|
Sensors for the detection of ammonia as a potential biomarker for health screening. Sci Rep 2021; 11:7185. [PMID: 33785837 PMCID: PMC8009942 DOI: 10.1038/s41598-021-86686-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Accepted: 03/17/2021] [Indexed: 02/06/2023] Open
Abstract
The presence of ammonia within the body has long been linked to complications stemming from the liver, kidneys, and stomach. These complications can be the result of serious conditions such as chronic kidney disease (CKD), peptic ulcers, and recently COVID-19. Limited liver and kidney function leads to increased blood urea nitrogen (BUN) within the body resulting in elevated levels of ammonia in the mouth, nose, and skin. Similarly, peptic ulcers, commonly from H. pylori, result in ammonia production from urea within the stomach. The presence of these biomarkers enables a potential screening protocol to be considered for frequent, non-invasive monitoring of these conditions. Unfortunately, detection of ammonia in these mediums is rather challenging due to relatively small concentrations and an abundance of interferents. Currently, there are no options available for non-invasive screening of these conditions continuously and in real-time. Here we demonstrate the selective detection of ammonia using a vapor phase thermodynamic sensing platform capable of being employed as part of a health screening protocol. The results show that our detection system has the remarkable ability to selectively detect trace levels of ammonia in the vapor phase using a single catalyst. Additionally, detection was demonstrated in the presence of interferents such as carbon dioxide (CO2) and acetone common in human breath. These results show that our thermodynamic sensors are well suited to selectively detect ammonia at levels that could potentially be useful for health screening applications.
Collapse
|
8
|
Breath Ammonia Is a Useful Biomarker Predicting Kidney Function in Chronic Kidney Disease Patients. Biomedicines 2020; 8:biomedicines8110468. [PMID: 33142890 PMCID: PMC7692127 DOI: 10.3390/biomedicines8110468] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 10/27/2020] [Accepted: 10/27/2020] [Indexed: 12/28/2022] Open
Abstract
Chronic kidney disease (CKD) is a public health problem and its prevalence has increased worldwide; patients are commonly unaware of the condition. The present study aimed to investigate whether exhaled breath ammonia via vertical-channel organic semiconductor (V-OSC) sensor measurement could be used for rapid CKD screening. We enrolled 121 CKD stage 1–5 patients, including 19 stage 1 patients, 26 stage 2 patients, 38 stage 3 patients, 21 stage 4 patients, and 17 stage 5 patients, from July 2019 to January 2020. Demographic and laboratory data were recorded. The exhaled ammonia was collected and rapidly measured by the V-OSC sensor to correlate with kidney function. Results showed no significant difference in age, sex, body weight, hemoglobin, albumin level, and comorbidities in different CKD stage patients. Correlation analysis demonstrated a good correlation between breath ammonia and blood urea nitrogen levels, serum creatinine levels, and estimated glomerular filtration rate (eGFR). Breath ammonia concentration was significantly elevated with increased CKD stage compared with the previous stage (CKD stage 1/2/3/4/5: 636 ± 94; 1020 ± 120; 1943 ± 326; 4421 ± 1042; 12781 ± 1807 ppb, p < 0.05). The receiver operating characteristic curve analysis showed an area under the curve (AUC) of 0.835 (p < 0.0001) for distinguishing CKD stage 1 from other CKD stages at 974 ppb (sensitivity, 69%; specificity, 95%). The AUC was 0.831 (p < 0.0001) for distinguishing between patients with/without eGFR < 60 mL/min/1.73 m2 (cutoff 1187 ppb: sensitivity, 71%; specificity, 78%). At 886 ppb, the sensitivity increased to 80% but the specificity decreased to 69%. This value is suitable for kidney function screening. Breath ammonia detection with V-OSC is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy.
Collapse
|
9
|
Perraud V, Li X, Smith JN, Finlayson-Pitts BJ. Novel ionization reagent for the measurement of gas-phase ammonia and amines using a stand-alone atmospheric pressure gas chromatography (APGC) source. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8561. [PMID: 31429122 DOI: 10.1002/rcm.8561] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 08/14/2019] [Accepted: 08/14/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Contaminants present in ambient air or in sampling lines can interfere with the target analysis through overlapping peaks or causing a high background. This study presents a positive outcome from the unexpected presence of N-methyl-2-pyrrolidone, released from a PALL HEPA filter, in the analysis of atmospherically relevant gas-phase amines using chemical ionization mass spectrometry. METHODS Gas-phase measurements were performed using a triple quadrupole mass spectrometer equipped with a modified atmospheric pressure gas chromatography (APGC) source which allows sampling of the headspace above pure amine standards. Gas-phase N-methyl-2-pyrrolidone (NMP) emitted from a PALL HEPA filter located in the inlet stream served as the ionizing agent. RESULTS This study demonstrates that some alkylamines efficiently form a [NMP + amine+H]+ cluster with NMP upon chemical ionization at atmospheric pressure. The extent of cluster formation depends largely on the proton affinity of the amine compared with that of NMP. Aromatic amines (aniline, pyridine) and diamines (putrescine) were shown not to form cluster ions with NMP. CONCLUSIONS The use of NMP as an ionizing agent with stand-alone APGC provided high sensitivity for ammonia and the smaller amines. The main advantages, in addition to sensitivity, are direct sampling into the APGC source and avoiding uptake on sampling lines which can be a significant problem with ammonia and amines.
Collapse
Affiliation(s)
- Véronique Perraud
- Department of Chemistry, University of California, Irvine, CA, 92697, USA
| | - Xiaoxiao Li
- Department of Chemistry, University of California, Irvine, CA, 92697, USA
| | - James N Smith
- Department of Chemistry, University of California, Irvine, CA, 92697, USA
| | | |
Collapse
|
10
|
Dumitras DC, Petrus M, Bratu AM, Popa C. Applications of Near Infrared Photoacoustic Spectroscopy for Analysis of Human Respiration: A Review. Molecules 2020; 25:E1728. [PMID: 32283766 PMCID: PMC7180475 DOI: 10.3390/molecules25071728] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 04/03/2020] [Accepted: 04/07/2020] [Indexed: 12/15/2022] Open
Abstract
In this review, applications of near-infrared photoacoustic spectroscopy are presented as an opportunity to evaluate human respiration because the measurement of breath is fast, intact and simple to implement. Recently, analytical methods for measuring biomarkers in exhaled air have been extensively developed. With laser-based photoacoustic spectroscopy, volatile organic compounds can be identified with high sensitivity, at a high rate, and with very good selectivity. The literature review has shown the applicability of near-infrared photoacoustic spectroscopy to one of the problems of the real world, i.e., human health. In addition, the review will consider and explore different breath sampling methods for human respiration analysis.
Collapse
Affiliation(s)
- Dan C. Dumitras
- University “Politehnica” of Bucharest, Physics Department, Faculty of Applied Sciences, University “Politehnica” of Bucharest, 313 Splaiul Independentei, 060042 Bucharest, Romania
| | - Mioara Petrus
- National Institute for Laser, Plasma and Radiation Physics, Laser Department, 409 Atomistilor St., PO Box MG 36, 077125 Magurele, Romania; (M.P.); (A.-M.B.); (C.P.)
| | - Ana-Maria Bratu
- National Institute for Laser, Plasma and Radiation Physics, Laser Department, 409 Atomistilor St., PO Box MG 36, 077125 Magurele, Romania; (M.P.); (A.-M.B.); (C.P.)
| | - Cristina Popa
- National Institute for Laser, Plasma and Radiation Physics, Laser Department, 409 Atomistilor St., PO Box MG 36, 077125 Magurele, Romania; (M.P.); (A.-M.B.); (C.P.)
| |
Collapse
|
11
|
Valente E, Araujo L, Carvalho S, Stahlhofer M. Breath ammonia as a bioindicator of protein nutrition in heifers. Livest Sci 2018. [DOI: 10.1016/j.livsci.2018.10.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
12
|
Karaca M, Martin-Levilain J, Grimaldi M, Li L, Dizin E, Emre Y, Maechler P. Liver Glutamate Dehydrogenase Controls Whole-Body Energy Partitioning Through Amino Acid-Derived Gluconeogenesis and Ammonia Homeostasis. Diabetes 2018; 67:1949-1961. [PMID: 30002133 DOI: 10.2337/db17-1561] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 07/01/2018] [Indexed: 11/13/2022]
Abstract
Ammonia detoxification and gluconeogenesis are major hepatic functions mutually connected through amino acid metabolism. The liver is rich in glutamate dehydrogenase (GDH) that catalyzes the reversible oxidative deamination of glutamate to α-ketoglutarate and ammonia, thus bridging amino acid-to-glucose pathways. Here we generated inducible liver-specific GDH-knockout mice (HepGlud1-/- ) to explore the role of hepatic GDH on metabolic homeostasis. Investigation of nitrogen metabolism revealed altered ammonia homeostasis in HepGlud1-/- mice characterized by increased circulating ammonia associated with reduced detoxification process into urea. The abrogation of hepatic GDH also modified energy homeostasis. In the fasting state, HepGlud1-/- mice could barely produce glucose in response to alanine due to impaired liver gluconeogenesis. Compared with control mice, lipid consumption in HepGlud1-/- mice was favored over carbohydrates as a compensatory energy fuel. The changes in energy partitioning induced by the lack of liver GDH modified the circadian rhythm of food intake. Overall, this study demonstrates the central role of hepatic GDH as a major regulator for the maintenance of ammonia and whole-body energy homeostasis.
Collapse
Affiliation(s)
- Melis Karaca
- Department of Cell Physiology and Metabolism, University of Geneva Medical School, Geneva, Switzerland
- Faculty Diabetes Center, University of Geneva Medical School, Geneva, Switzerland
| | - Juliette Martin-Levilain
- Department of Cell Physiology and Metabolism, University of Geneva Medical School, Geneva, Switzerland
- Faculty Diabetes Center, University of Geneva Medical School, Geneva, Switzerland
| | - Mariagrazia Grimaldi
- Department of Cell Physiology and Metabolism, University of Geneva Medical School, Geneva, Switzerland
- Faculty Diabetes Center, University of Geneva Medical School, Geneva, Switzerland
| | - Lingzi Li
- Department of Cell Physiology and Metabolism, University of Geneva Medical School, Geneva, Switzerland
- Faculty Diabetes Center, University of Geneva Medical School, Geneva, Switzerland
| | - Eva Dizin
- Department of Cell Physiology and Metabolism, University of Geneva Medical School, Geneva, Switzerland
| | - Yalin Emre
- Department of Pathology and Immunology, University of Geneva Medical School, Geneva, Switzerland
| | - Pierre Maechler
- Department of Cell Physiology and Metabolism, University of Geneva Medical School, Geneva, Switzerland
- Faculty Diabetes Center, University of Geneva Medical School, Geneva, Switzerland
| |
Collapse
|
13
|
Popa C, Bratu AM, Petrus M. A comparative photoacoustic study of multi gases from human respiration: mouth breathing vs. nasal breathing. Microchem J 2018. [DOI: 10.1016/j.microc.2018.02.030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
14
|
Španěl P, Smith D. What is the real utility of breath ammonia concentration measurements in medicine and physiology? J Breath Res 2018; 12:027102. [PMID: 28972201 DOI: 10.1088/1752-7163/aa907f] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Much effort continues to be devoted to the development of devices to analyse breath ammonia with the anticipation that breath ammonia analyses will be useful in clinical practice. In this perspective we refer to the analytical techniques that have been used to measure breath ammonia, focusing on selected ion flow tube mass spectrometry, SIFT-MS, of which we have special knowledge and understanding. From the collected data obtained using the different techniques, we exam the origins of mouth- and nose-exhaled ammonia and conclude that mouth-exhaled ammonia is always elevated above a concentration that would be equilibrated with blood ammonia and is largely produced by the action of enzymes on salivary urea. Support to this conclusion is given by the reasonable correlation between blood urea concentration and mouth-exhaled ammonia concentration. Further, it is discussed that nose-exhaled ammonia largely originates at the alveolar interface and so its concentration more closely relates to the expected alveolar blood ammonia concentration. Ingestion of proteins results in increased blood/saliva urea and ultimately mouth-exhaled ammonia as does the generation of urease by H. pylori infection. It is also concluded that when mouth-exhaled ammonia is elevated then it may be due to either abnormally high blood urea, a high pH of the saliva/mouth/airways mucosa, poor oral hygiene or a combinations of these.
Collapse
Affiliation(s)
- Patrik Španěl
- J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, v.v.i., Dolejškova 3, 182 23 Prague 8, Czechia
| | | |
Collapse
|
15
|
Mun S, Park Y, Lee YEK, Sung MM. Highly Sensitive Ammonia Gas Sensor Based on Single-Crystal Poly(3-hexylthiophene) (P3HT) Organic Field Effect Transistor. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2017; 33:13554-13560. [PMID: 29125766 DOI: 10.1021/acs.langmuir.7b02466] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A highly sensitive organic field-effect transistor (OFET)-based sensor for ammonia in the range of 0.01 to 25 ppm was developed. The sensor was fabricated by employing an array of single-crystal poly(3-hexylthiophene) (P3HT) nanowires as the organic semiconductor (OSC) layer of an OFET with a top-contact geometry. The electrical characteristics (field-effect mobility, on/off current ratio) of the single-crystal P3HT nanowire OFET were about 2 orders of magnitude larger than those of the P3HT thin film OFET with the same geometry. The P3HT nanowire OFET showed excellent sensitivity to ammonia, about 3 times higher than that of the P3HT thin film OFET at 25 ppm ammonia. The ammonia response of the OFET was reversible and was not affected by changes in relative humidity from 45 to 100%. The high ammonia sensitivity of the P3HT nanowire OFET is believed to result from the single crystal nature and high surface/volume ratio of the P3HT nanowire used in the OSC layer.
Collapse
Affiliation(s)
- Seohyun Mun
- Department of Chemistry, Hanyang University , Seoul 04763, Korea
| | - Yoonkyung Park
- Department of Chemistry, Hanyang University , Seoul 04763, Korea
| | - Yong-Eun Koo Lee
- Department of Chemistry, Hanyang University , Seoul 04763, Korea
| | - Myung Mo Sung
- Department of Chemistry, Hanyang University , Seoul 04763, Korea
| |
Collapse
|
16
|
Yan H, Zhong M, Lv Z, Wan P. Stretchable Electronic Sensors of Nanocomposite Network Films for Ultrasensitive Chemical Vapor Sensing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2017; 13:1701697. [PMID: 28895272 DOI: 10.1002/smll.201701697] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 08/01/2017] [Indexed: 06/07/2023]
Abstract
A stretchable, transparent, and body-attachable chemical sensor is assembled from the stretchable nanocomposite network film for ultrasensitive chemical vapor sensing. The stretchable nanocomposite network film is fabricated by in situ preparation of polyaniline/MoS2 (PANI/MoS2 ) nanocomposite in MoS2 suspension and simultaneously nanocomposite deposition onto prestrain elastomeric polydimethylsiloxane substrate. The assembled stretchable electronic sensor demonstrates ultrasensitive sensing performance as low as 50 ppb, robust sensing stability, and reliable stretchability for high-performance chemical vapor sensing. The ultrasensitive sensing performance of the stretchable electronic sensors could be ascribed to the synergistic sensing advantages of MoS2 and PANI, higher specific surface area, the reliable sensing channels of interconnected network, and the effectively exposed sensing materials. It is expected to hold great promise for assembling various flexible stretchable chemical vapor sensors with ultrasensitive sensing performance, superior sensing stability, reliable stretchability, and robust portability to be potentially integrated into wearable electronics for real-time monitoring of environment safety and human healthcare.
Collapse
Affiliation(s)
- Hong Yan
- Center of Advanced Elastomer Materials, State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
| | - Mengjuan Zhong
- Center of Advanced Elastomer Materials, State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
| | - Ze Lv
- Center of Advanced Elastomer Materials, State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
| | - Pengbo Wan
- Center of Advanced Elastomer Materials, State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, 100029, P. R. China
| |
Collapse
|
17
|
Kumbhani SR, Wingen LM, Perraud V, Finlayson-Pitts BJ. A cautionary note on the effects of laboratory air contaminants on ambient ionization mass spectrometry measurements. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2017; 31:1659-1668. [PMID: 28782138 DOI: 10.1002/rcm.7951] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Revised: 08/01/2017] [Accepted: 08/02/2017] [Indexed: 06/07/2023]
Abstract
RATIONALE Ambient ionization mass spectrometry methods are convenient, sensitive and require little sample preparation. However, they are susceptible to species present in air surrounding the mass spectrometer. This study identifies some challenges associated with the potential impacts of indoor air contaminants on ionization and analysis involving open-air methods. METHODS Unexpected effects of volatile organic compounds (VOCs) from floor maintenance activities on ambient ionization mass spectrometry were studied using three different ambient ionization techniques. Extractive electrospray ionization (EESI), direct analysis in real time (DART) and ionization by piezoelectric direct discharge (PDD) plasma were demonstrated in this study to be affected by indoor air contaminants. Identification of contaminant vapors was verified by comparison with standards using EESI-MS/MS product ion scans. RESULTS Emissions of diethylene glycol monoethyl ether and ethylene glycol monobutyl ether are identified from floor stripping and waxing solutions using three ambient ionization mass spectrometry techniques. These unexpected indoor air contaminants are capable of more than 75% ion suppression of target analytes due to their high volatility, proton affinity and solubility compared with the target analytes. The contaminant vapors are also shown to form adducts with one of the target analytes. CONCLUSIONS The common practice in MS analysis of subtracting a background air spectrum may not be appropriate if the presence of ionizable air contaminants alters the spectrum in unexpected ways. For example, VOCs released into air from floor stripping and waxing are capable of causing ion suppression of target analytes.
Collapse
Affiliation(s)
- Sambhav R Kumbhani
- Department of Chemistry, University of California, Irvine, Irvine, CA, 92697-2025, USA
| | - Lisa M Wingen
- Department of Chemistry, University of California, Irvine, Irvine, CA, 92697-2025, USA
| | - Véronique Perraud
- Department of Chemistry, University of California, Irvine, Irvine, CA, 92697-2025, USA
| | | |
Collapse
|
18
|
Monasta L, Pierobon C, Princivalle A, Martelossi S, Marcuzzi A, Pasini F, Perbellini L. Inflammatory bowel disease and patterns of volatile organic compounds in the exhaled breath of children: A case-control study using Ion Molecule Reaction-Mass Spectrometry. PLoS One 2017; 12:e0184118. [PMID: 28859138 PMCID: PMC5578606 DOI: 10.1371/journal.pone.0184118] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Accepted: 08/20/2017] [Indexed: 12/22/2022] Open
Abstract
Inflammatory bowel diseases (IBD) profoundly affect quality of life and have been gradually increasing in incidence, prevalence and severity in many areas of the world, and in children in particular. Patients with suspected IBD require careful history and clinical examination, while definitive diagnosis relies on endoscopic and histological findings. The aim of the present study was to investigate whether the alveolar air of pediatric patients with IBD presents a specific volatile organic compounds’ (VOCs) pattern when compared to controls. Patients 10–17 years of age, were divided into four groups: Crohn’s disease (CD), ulcerative colitis (UC), controls with gastrointestinal symptomatology, and surgical controls with no evidence of gastrointestinal problems. Alveolar breath was analyzed by ion molecule reaction mass spectrometry. Four models were built starting from 81 molecules plus the age of subjects as independent variables, adopting a penalizing LASSO logistic regression approach: 1) IBDs vs. controls, finally based on 18 VOCs plus age (sensitivity = 95%, specificity = 69%, AUC = 0.925); 2) CD vs. UC, finally based on 13 VOCs plus age (sensitivity = 94%, specificity = 76%, AUC = 0.934); 3) IBDs vs. gastroenterological controls, finally based on 15 VOCs plus age (sensitivity = 94%, specificity = 65%, AUC = 0.918); 4) IBDs vs. controls, built starting from the 21 directly or indirectly calibrated molecules only, and finally based on 12 VOCs plus age (sensitivity = 94%, specificity = 71%, AUC = 0.888). The molecules identified by the models were carefully studied in relation to the concerned outcomes. This study, with the creation of models based on VOCs profiles, precise instrumentation and advanced statistical methods, can contribute to the development of new non–invasive, fast and relatively inexpensive diagnostic tools, with high sensitivity and specificity. It also represents a crucial step towards gaining further insights on the etiology of IBD through the analysis of specific molecules which are the expression of the particular metabolism that characterizes these patients.
Collapse
Affiliation(s)
- Lorenzo Monasta
- Institute for Maternal and Child Health – IRCCS “Burlo Garofolo”, Trieste, Italy
- * E-mail:
| | - Chiara Pierobon
- Institute for Maternal and Child Health – IRCCS “Burlo Garofolo”, Trieste, Italy
| | - Andrea Princivalle
- Occupational Medicine, Department of Public Health and Community Medicine, University of Verona, Verona, Italy
| | - Stefano Martelossi
- Institute for Maternal and Child Health – IRCCS “Burlo Garofolo”, Trieste, Italy
| | - Annalisa Marcuzzi
- Institute for Maternal and Child Health – IRCCS “Burlo Garofolo”, Trieste, Italy
| | - Francesco Pasini
- Occupational Medicine, Department of Public Health and Community Medicine, University of Verona, Verona, Italy
| | - Luigi Perbellini
- Occupational Medicine, Department of Public Health and Community Medicine, University of Verona, Verona, Italy
| |
Collapse
|
19
|
Bayrakli I, Turkmen A, Akman H, Sezer MT, Kutluhan S. Applications of external cavity diode laser-based technique to noninvasive clinical diagnosis using expired breath ammonia analysis: chronic kidney disease, epilepsy. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:87004. [PMID: 27533447 DOI: 10.1117/1.jbo.21.8.087004] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2016] [Accepted: 07/25/2016] [Indexed: 06/06/2023]
Abstract
An external cavity laser (ECL)-based off-axis cavity-enhanced absorption spectroscopy was applied to noninvasive clinical diagnosis using expired breath ammonia analysis: (1) the correlation between breath ammonia levels and blood parameters related to chronic kidney disease (CKD) was investigated and (2) the relationship between breath ammonia levels and blood concentrations of valproic acid (VAP) was studied. The concentrations of breath ammonia in 15 healthy volunteers, 10 epilepsy patients (before and after taking VAP), and 27 patients with different stages of CKD were examined. The range of breath ammonia levels was 120 to 530 ppb for healthy subjects and 710 to 10,400 ppb for patients with CKD. There was a statistically significant positive correlation between breath ammonia concentrations and urea, blood urea nitrogen, creatinine, or estimated glomerular filtration rate in 27 patients. It was demonstrated that taking VAP gave rise to increasing breath ammonia levels. A statistically significant difference was found between the levels of exhaled ammonia (NH3) in healthy subjects and in patients with epilepsy before and after taking VAP. The results suggest that our breath ammonia measurement system has great potential as an easy, noninvasive, real-time, and continuous monitor of the clinical parameters related to epilepsy and CKD.
Collapse
Affiliation(s)
- Ismail Bayrakli
- Suleyman Demirel University, Biomedical Engineering, Bati kampüsü Isparta, Turkey
| | - Aysenur Turkmen
- Suleyman Demirel University, Biomedical Engineering, Bati kampüsü Isparta, Turkey
| | - Hatice Akman
- Suleyman Demirel University, Biomedical Engineering, Bati kampüsü Isparta, Turkey
| | - M Tugrul Sezer
- Suleyman Demirel University, School of Medicine, Department of Nephrology, Dogu kampüsü Isparta, Turkey
| | - Suleyman Kutluhan
- Suleyman Demirel University, School of Medicine, Department of Neurology, Dogu kampüsü, Isparta, Turkey
| |
Collapse
|
20
|
Bayrakli I, Turkmen A, Cem Kockar M. Feasibility Study of Using Breath Ammonia Analysis Based on Off-Axis Cavity-Enhanced Absorption Spectroscopy with External Cavity Diode Laser for Noninvasive Real-Time Diagnosis of Helicobacter Pylori. APPLIED SPECTROSCOPY 2016; 70:1269-1277. [PMID: 27296306 DOI: 10.1177/0003702816654052] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Accepted: 11/26/2015] [Indexed: 06/06/2023]
Abstract
The purpose of this study is to assess the feasibility of using breath ammonia analysis based on off-axis cavity-enhanced absorption spectroscopy (OA-CEAS) with an external-cavity diode laser (ECL) for noninvasive, real-time diagnosis of Helicobacter pylori (HP) infection. Analyses are performed for the breath of 15 healthy volunteers, and eight children and 19 adults with HP infection. The range of ammonia levels for healthy participants is determined to be between 178 and 610 ppb, whereas the ranges for child and adult patients with HP infection are measured to be 457-2470 ppb and 450-2990 ppb, respectively. The ammonia concentrations for patients with HP infection are significantly higher than the concentrations for healthy volunteers. However, no sharp boundary between the ammonia concentrations in the breath of patients with HP infection and healthy volunteers is observed. No correlation between breath ammonia and either body mass index (BMI) or age is found. The reported results suggest that our breath ammonia measurement system has the potential for future use in easy, noninvasive diagnosis of HP infection.
Collapse
Affiliation(s)
- Ismail Bayrakli
- Suleyman Demirel University, Biomedical Engineering, Bati kampusu, Isparta, Turkey
| | - Aysenur Turkmen
- Suleyman Demirel University, Biomedical Engineering, Bati kampusu, Isparta, Turkey
| | - Muhammet Cem Kockar
- Suleyman Demirel University, School of Medicine, Dogu kampusu, Isparta, Turkey
| |
Collapse
|
21
|
Brannelly NT, Hamilton-Shield JP, Killard AJ. The Measurement of Ammonia in Human Breath and its Potential in Clinical Diagnostics. Crit Rev Anal Chem 2016; 46:490-501. [PMID: 26907707 DOI: 10.1080/10408347.2016.1153949] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Ammonia is an important component of metabolism and is involved in many physiological processes. During normal physiology, levels of blood ammonia are between 11 and 50 µM. Elevated blood ammonia levels are associated with a variety of pathological conditions such as liver and kidney dysfunction, Reye's syndrome and a variety of inborn errors of metabolism including urea cycle disorders (UCD), organic acidaemias and hyperinsulinism/hyperammonaemia syndrome in which ammonia may reach levels in excess of 1 mM. It is highly neurotoxic and so effective measurement is critical for assessing and monitoring disease severity and treatment. Ammonia is also a potential biomarker in exercise physiology and studies of drug metabolism. Current ammonia testing is based on blood sampling, which is inconvenient and can be subject to significant analytical errors due to the quality of the sample draw, its handling and preparation for analysis. Blood ammonia is in gaseous equilibrium with the lungs. Recent research has demonstrated the potential use of breath ammonia as a non-invasive means of measuring systemic ammonia. This requires measurement of ammonia in real breath samples with associated temperature, humidity and gas characteristics at concentrations between 50 and several thousand parts per billion. This review explores the diagnostic applications of ammonia measurement and the impact that the move from blood to breath analysis could have on how these processes and diseases are studied and managed.
Collapse
Affiliation(s)
- N T Brannelly
- a Department of Biological Biomedical and Analytical Science , University of the West of England , Bristol , UK
| | | | - A J Killard
- a Department of Biological Biomedical and Analytical Science , University of the West of England , Bristol , UK
| |
Collapse
|
22
|
Spacek LA, Mudalel ML, Lewicki R, Tittel FK, Risby TH, Stoltzfus J, Munier JJ, Solga SF. Breath ammonia and ethanol increase in response to a high protein challenge. Biomarkers 2015; 20:149-56. [PMID: 26043432 DOI: 10.3109/1354750x.2015.1040840] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Quantifying changes in ammonia and ethanol in blood and body fluid assays in response to food is cumbersome. We used breath analysis of ammonia, ethanol, hydrogen (an accepted standard of gut transit) and acetone to investigate gastrointestinal physiology. In 30 healthy participants, we measured each metabolite serially over 6 h in control and high protein trials. Two-way repeated measures ANOVA compared treatment (control versus intervention), change from baseline to maximum and interaction of treatment and time change. Interaction was significant for ammonia (p < 0.0001) and hydrogen (p < 0.0001). We describe the dynamic measurement of multiple metabolites in response to an oral challenge.
Collapse
Affiliation(s)
- Lisa A Spacek
- Department of Medicine, School of Medicine, Johns Hopkins University , Baltimore, MD , USA
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Mikhaylov S, Ogurtsov N, Noskov Y, Redon N, Coddeville P, Wojkiewicz JL, Pud A. Ammonia/amine electronic gas sensors based on hybrid polyaniline–TiO2 nanocomposites. The effects of titania and the surface active doping acid. RSC Adv 2015. [DOI: 10.1039/c4ra16121a] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Morphology and sensor responses.
Collapse
Affiliation(s)
- S. Mikhaylov
- Institute of Bioorganic Chemistry and Petrochemistry
- National Academy of Sciences of Ukraine
- Kyiv
- Ukraine
- Mines Douai
| | - N. Ogurtsov
- Institute of Bioorganic Chemistry and Petrochemistry
- National Academy of Sciences of Ukraine
- Kyiv
- Ukraine
| | - Yu. Noskov
- Institute of Bioorganic Chemistry and Petrochemistry
- National Academy of Sciences of Ukraine
- Kyiv
- Ukraine
| | - N. Redon
- Mines Douai
- Département Sciences de l'Atmosphère et Génie de l'Environnement (SAGE)
- F-59508 Douai
- France
| | - P. Coddeville
- Mines Douai
- Département Sciences de l'Atmosphère et Génie de l'Environnement (SAGE)
- F-59508 Douai
- France
| | - J.-L. Wojkiewicz
- Mines Douai
- Département Sciences de l'Atmosphère et Génie de l'Environnement (SAGE)
- F-59508 Douai
- France
| | - A. Pud
- Institute of Bioorganic Chemistry and Petrochemistry
- National Academy of Sciences of Ukraine
- Kyiv
- Ukraine
| |
Collapse
|
24
|
Abstract
It is known that the oral cavity is a production site for mouth-exhaled NH3. However, the mechanism of NH3 production in the oral cavity has been unclear. Since bacterial urease in the oral cavity has been found to produce ammonia from oral fluid urea, we hypothesize that oral fluid urea is the origin of mouth-exhaled NH3. Our results show that under certain conditions a strong correlation exists between oral fluid urea and oral fluid ammonia (NH4(+)+NH3) (rs = 0.77, p < 0.001). We also observe a strong correlation between oral fluid NH3 and mouth-exhaled NH3 (rs = 0.81, p < 0.001). We conclude that three main factors affect the mouth-exhaled NH3 concentration: urea concentration, urease activity and oral fluid pH. Bacterial urease catalyses the hydrolysis of oral fluid urea to ammonia (NH4(+)+NH3). Oral fluid ammonia (NH4(+)+NH3) and pH determine the concentration of oral fluid NH3, which evaporates from oral fluid into gas phase and turns to mouth-exhaled NH3.
Collapse
Affiliation(s)
- W Chen
- Laboratory of Physical Chemistry, Department of Chemistry, PO Box 55 (A. I. Virtasen aukio 1), FI-00014 University of Helsinki, Finland
| | | | | | | |
Collapse
|
25
|
Amann A, Costello BDL, Miekisch W, Schubert J, Buszewski B, Pleil J, Ratcliffe N, Risby T. The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva. J Breath Res 2014; 8:034001. [PMID: 24946087 DOI: 10.1088/1752-7155/8/3/034001] [Citation(s) in RCA: 361] [Impact Index Per Article: 36.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Breath analysis is a young field of research with its roots in antiquity. Antoine Lavoisier discovered carbon dioxide in exhaled breath during the period 1777-1783, Wilhelm (Vilém) Petters discovered acetone in breath in 1857 and Johannes Müller reported the first quantitative measurements of acetone in 1898. A recent review reported 1765 volatile compounds appearing in exhaled breath, skin emanations, urine, saliva, human breast milk, blood and feces. For a large number of compounds, real-time analysis of exhaled breath or skin emanations has been performed, e.g., during exertion of effort on a stationary bicycle or during sleep. Volatile compounds in exhaled breath, which record historical exposure, are called the 'exposome'. Changes in biogenic volatile organic compound concentrations can be used to mirror metabolic or (patho)physiological processes in the whole body or blood concentrations of drugs (e.g. propofol) in clinical settings-even during artificial ventilation or during surgery. Also compounds released by bacterial strains like Pseudomonas aeruginosa or Streptococcus pneumonia could be very interesting. Methyl methacrylate (CAS 80-62-6), for example, was observed in the headspace of Streptococcus pneumonia in concentrations up to 1420 ppb. Fecal volatiles have been implicated in differentiating certain infectious bowel diseases such as Clostridium difficile, Campylobacter, Salmonella and Cholera. They have also been used to differentiate other non-infectious conditions such as irritable bowel syndrome and inflammatory bowel disease. In addition, alterations in urine volatiles have been used to detect urinary tract infections, bladder, prostate and other cancers. Peroxidation of lipids and other biomolecules by reactive oxygen species produce volatile compounds like ethane and 1-pentane. Noninvasive detection and therapeutic monitoring of oxidative stress would be highly desirable in autoimmunological, neurological, inflammatory diseases and cancer, but also during surgery and in intensive care units. The investigation of cell cultures opens up new possibilities for elucidation of the biochemical background of volatile compounds. In future studies, combined investigations of a particular compound with regard to human matrices such as breath, urine, saliva and cell culture investigations will lead to novel scientific progress in the field.
Collapse
Affiliation(s)
- Anton Amann
- Univ-Clinic for Anesthesia and Intensive Care, Innsbruck Medical University, Anichstr, 35, A-6020 Innsbruck, Austria. Breath Research Institute of the University of Innsbruck, Rathausplatz 4, A-6850 Dornbirn, Austria
| | | | | | | | | | | | | | | |
Collapse
|
26
|
|
27
|
Breath analysis of ammonia, volatile organic compounds and deuterated water vapor in chronic kidney disease and during dialysis. Bioanalysis 2014; 6:843-57. [DOI: 10.4155/bio.14.26] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
The volatile metabolites present in trace amounts in exhaled breath of healthy individuals and patients, for example those with advanced chronic kidney disease (CKD), can now be detected and quantified by sensitive analytical techniques. In this review, special attention is given to the major retention metabolites resulting from dialysis-dependent CKD stage 5 and especially ammonia, as a potential estimator of the severity of uremia. However, other biomarkers are important, including the hydrocarbons isoprene, ethane and pentane, in that they are likely to indicate tissue injury associated with the dialysis treatment itself. Evaluation of over-hydration, a serious complication of CKD stage5 can be improved by analysis of deuterium in exhaled water vapor after ingestion of a known amount of deuterated water, so providing total body water measurements at the bedside to support clinical management of volume status.
Collapse
|
28
|
Direct analysis of human breath ammonia using corona discharge ion mobility spectrometry. J Pharm Biomed Anal 2014; 88:315-20. [DOI: 10.1016/j.jpba.2013.08.047] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2013] [Revised: 08/24/2013] [Accepted: 08/27/2013] [Indexed: 01/13/2023]
|
29
|
Hibbard T, Crowley K, Kelly F, Ward F, Holian J, Watson A, Killard AJ. Point of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors. Anal Chem 2013; 85:12158-65. [PMID: 24299143 DOI: 10.1021/ac403472d] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
A device for measuring human breath ammonia was developed based on a single use, disposable, inkjet printed ammonia sensor fabricated using polyaniline nanoparticles. The device was optimized for sampling ammonia in human breath samples by addressing issues such as variations in breath sample volume, flow rate, sources of oral ammonia, temperature and humidity. The resulting system was capable of measuring ammonia in breath from 40 to 2993 ppbv (r(2 )= 0.99, n = 3) as correlated with photoacoustic laser spectroscopy and correlation in normal human breath samples yielded a slope of 0.93 and a Pearson correlation coefficient of 0.9705 (p < 0.05, n = 11). Measurement of ammonia in the breath of patients with end-stage kidney disease demonstrated its significant reduction following dialysis, while also correlating well with blood urea nitrogen (BUN) (r = 0.61, p < 0.01, n = 96). Excellent intraindividual correlations were demonstrated between breath ammonia and BUN (0.86 to 0.96), which demonstrates the possibility of using low cost point of care breath ammonia systems as a noninvasive means of monitoring kidney dysfunction and treatment.
Collapse
Affiliation(s)
- Troy Hibbard
- Biomedical Diagnostics Institute, Dublin City University , Dublin D9, Ireland
| | | | | | | | | | | | | |
Collapse
|
30
|
Solga SF, Mudalel M, Spacek LA, Lewicki R, Tittel F, Loccioni C, Russo A, Risby TH. Factors influencing breath ammonia determination. J Breath Res 2013; 7:037101. [PMID: 23774041 DOI: 10.1088/1752-7155/7/3/037101] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Amongst volatile compounds (VCs) present in exhaled breath, ammonia has held great promise and yet it has confounded researchers due to its inherent reactivity. Herein we have evaluated various factors in both breath instrumentation and the breath collection process in an effort to reduce variability. We found that the temperature of breath sampler and breath sensor, mouth rinse pH, and mode of breathing to be important factors. The influence of the rinses is heavily dependent upon the pH of the rinse. The basic rinse (pH 8.0) caused a mean increase of the ammonia concentration by 410 ± 221 ppb. The neutral rinse (pH 7.0), slightly acidic rinse (pH 5.8), and acidic rinse (pH 2.5) caused a mean decrease of the ammonia concentration by 498 ± 355 ppb, 527 ± 198 ppb, and 596 ± 385 ppb, respectively. Mode of breathing (mouth-open versus mouth-closed) demonstrated itself to have a large impact on the rate of recovery of breath ammonia after a water rinse. Within 30 min, breath ammonia returned to 98 ± 16% that of the baseline with mouth open breathing, while mouth closed breathing allowed breath ammonia to return to 53 ± 14% of baseline. These results contribute to a growing body of literature that will improve reproducibly in ammonia and other VCs.
Collapse
|
31
|
Hibbard T, Crowley K, Killard AJ. Direct measurement of ammonia in simulated human breath using an inkjet-printed polyaniline nanoparticle sensor. Anal Chim Acta 2013; 779:56-63. [PMID: 23663672 DOI: 10.1016/j.aca.2013.03.051] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2012] [Revised: 02/13/2013] [Accepted: 03/18/2013] [Indexed: 12/28/2022]
Abstract
A sensor fabricated from the inkjet-printed deposition of polyaniline nanoparticles onto a screen-printed silver interdigitated electrode was developed for the detection of ammonia in simulated human breath samples. Impedance analysis showed that exposure to ammonia gas could be measured at 962 Hz at which changes in resistance dominate due to the deprotonation of the polymer film. Sensors required minimal calibration and demonstrated excellent intra-electrode baseline drift (≤1.67%). Gases typically present in breath did not interfere with the sensor. Temperature and humidity were shown to have characteristic impedimetric and temporal effects on the sensor that could be distinguished from the response to ammonia. While impedance responses to ammonia could be detected from a single simulated breath, quantification was improved after the cumulative measurement of multiple breaths. The measurement of ammonia after 16 simulated breaths was linear in the range of 40-2175 ppbv (27-1514 μg m(-3)) (r(2)=0.9963) with a theoretical limit of detection of 6.2 ppbv (4.1 μg m(-3)) (SN(-1)=3).
Collapse
Affiliation(s)
- Troy Hibbard
- Biomedical Diagnostics Institute, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland
| | | | | |
Collapse
|
32
|
Dai MZ, Lin YL, Lin HC, Zan HW, Chang KT, Meng HF, Liao JW, Tsai MJ, Cheng H. Highly Sensitive Ammonia Sensor with Organic Vertical Nanojunctions for Noninvasive Detection of Hepatic Injury. Anal Chem 2013; 85:3110-7. [DOI: 10.1021/ac303100k] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Ming-Zhi Dai
- Institute of Physics, National Chiao Tung University, Hsinchu, Taiwan
| | - Yi-Lo Lin
- Graduate Institute of Veterinary
Pathobiology, College of Veterinary Medicine, National Chung Hsing University, Taichung, Taiwan
- Neural Regeneration Laboratory,
Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Hung-Cheng Lin
- Department of Photonics, National Chiao Tung University, Hsinchu, Taiwan
| | - Hsiao-Wen Zan
- Department of Photonics, National Chiao Tung University, Hsinchu, Taiwan
| | - Kai-Ting Chang
- Neural Regeneration Laboratory,
Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- Department and Institute of
Pharmacology, School of Medicine, National Yang-Ming University, Taipei, Taiwan
| | - Hsin-Fei Meng
- Institute of Physics, National Chiao Tung University, Hsinchu, Taiwan
| | - Jiunn-Wang Liao
- Graduate Institute of Veterinary
Pathobiology, College of Veterinary Medicine, National Chung Hsing University, Taichung, Taiwan
| | - May-Jywan Tsai
- Neural Regeneration Laboratory,
Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Henrich Cheng
- Neural Regeneration Laboratory,
Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- Department and Institute of
Pharmacology, School of Medicine, National Yang-Ming University, Taipei, Taiwan
- Center for Neural Regeneration,
Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- Brain Research Center, School
of Medicine, National Yang-Ming University, Taipei, Taiwan
| |
Collapse
|
33
|
Schmidt FM, Vaittinen O, Metsälä M, Lehto M, Forsblom C, Groop PH, Halonen L. Ammonia in breath and emitted from skin. J Breath Res 2013; 7:017109. [PMID: 23445955 DOI: 10.1088/1752-7155/7/1/017109] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Ammonia concentrations in exhaled breath (eNH3) and skin gas of 20 healthy subjects were measured on-line with a commercial cavity ring-down spectrometer and compared to saliva pH and plasma ammonium ion (NH(+)4), urea and creatinine concentrations. Special attention was given to mouth, nose and skin sampling procedures and the accurate quantification of ammonia in humid gas samples. The obtained median concentrations were 688 parts per billion by volume (ppbv) for mouth-eNH3, 34 ppbv for nose-eNH3, and 21 ppbv for both mouth- and nose-eNH3 after an acidic mouth wash (MW). The median ammonia emission rate from the lower forearm was 0.3 ng cm(-2) min(-1). Statistically significant (p < 0.05) correlations between the breath, skin and plasma ammonia/ammonium concentrations were not found. However, mouth-eNH3 strongly (p < 0.001) correlated with saliva pH. This dependence was also observed in detailed measurements of the diurnal variation and the response of eNH3 to the acidic MW. It is concluded that eNH3 as such does not reflect plasma but saliva and airway mucus NH(+)4 concentrations and is affected by saliva and airway mucus pH. After normalization with saliva pH using the Henderson-Hasselbalch equation, mouth-eNH3 correlated with plasma NH(+)4, which points to saliva and plasma NH(+)4 being linked via hydrolysis of salivary urea.
Collapse
Affiliation(s)
- F M Schmidt
- Laboratory of Physical Chemistry, Department of Chemistry, University of Helsinki, Finland.
| | | | | | | | | | | | | |
Collapse
|
34
|
Human biomarkers in breath by photoacoustic spectroscopy. Clin Chim Acta 2012; 413:1171-8. [DOI: 10.1016/j.cca.2012.04.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2012] [Revised: 03/04/2012] [Accepted: 04/06/2012] [Indexed: 11/22/2022]
|