1
|
Hafid A, Zolfaghari S, Kristoffersson A, Folke M. Exploring the potential of electrical bioimpedance technique for analyzing physical activity. Front Physiol 2024; 15:1515431. [PMID: 39759110 PMCID: PMC11696282 DOI: 10.3389/fphys.2024.1515431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2024] [Accepted: 12/03/2024] [Indexed: 01/07/2025] Open
Abstract
Introduction Exercise physiology investigates the complex and multifaceted human body responses to physical activity (PA). The integration of electrical bioimpedance (EBI) has emerged as a valuable tool for deepening our understanding of muscle activity during exercise. Method In this study, we investigate the potential of using the EBI technique for human motion recognition. We analyze EBI signals from the quadriceps muscle and extensor digitorum longus muscle acquired when healthy participants in the range 20-30 years of age performed four lower body PAs, namely squats, lunges, balance walk, and short jumps. Results The characteristics of EBI signals are promising for analyzing PAs. Each evaluated PA exhibited unique EBI signal characteristics. Discussion The variability in how PAs are executed leads to variations in the EBI signal characteristics, which, in turn, can provide insights into individual differences in how a person executes a specific PA.
Collapse
Affiliation(s)
- Abdelakram Hafid
- Division of Intelligent Future Technologies, School of Innovation, Design and Technology, Mälardalen University, Västerås, Sweden
| | | | | | | |
Collapse
|
2
|
Ozmen GC, Mabrouk S, Nichols C, Berkebile J, Goossens Q, Gazi AH, Inan OT. Mid-Activity and At-Home Wearable Bioimpedance Elucidates an Interpretable Digital Biomarker of Muscle Fatigue. IEEE Trans Biomed Eng 2023; 70:3513-3524. [PMID: 37405890 PMCID: PMC11092386 DOI: 10.1109/tbme.2023.3290530] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/07/2023]
Abstract
OBJECTIVE Muscle health and decreased muscle performance (fatigue) quantification has proven to be an invaluable tool for both athletic performance assessment and injury prevention. However, existing methods estimating muscle fatigue are infeasible for everyday use. Wearable technologies are feasible for everyday use and can enable discovery of digital biomarkers of muscle fatigue. Unfortunately, the current state-of-the-art wearable systems for muscle fatigue tracking suffer from either low specificity or poor usability. METHODS We propose using dual-frequency bioimpedance analysis (DFBIA) to non-invasively assess intramuscular fluid dynamics and thereby muscle fatigue. A wearable DFBIA system was developed to measure leg muscle fatigue of 11 individuals during a 13-day protocol consisting of exercise and unsupervised at-home portions. RESULTS We derived a digital biomarker of muscle fatigue, fatigue score, from the DFBIA signals that was able to estimate the percent reduction in muscle force during exercise with repeated-measures Pearson's r = 0.90 and mean absolute error (MAE) of 3.6%. This fatigue score also estimated delayed onset muscle soreness with repeated-measures Pearson's r = 0.83 and MAE = 0.83. Using at-home data, DFBIA was strongly associated with absolute muscle force of participants (n = 198, p < 0.001). CONCLUSION These results demonstrate the utility of wearable DFBIA for non-invasively estimating muscle force and pain through the changes in intramuscular fluid dynamics. SIGNIFICANCE The presented approach may inform development of future wearable systems for quantifying muscle health and provide a novel framework for athletic performance optimization and injury prevention.
Collapse
|
3
|
Critcher S, Parmelee P, Freeborn TJ. Localized Multi-Site Knee Bioimpedance as a Predictor for Knee Osteoarthritis Associated Pain Within Older Adults During Free-Living. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2023; 4:1-10. [PMID: 37138591 PMCID: PMC10151013 DOI: 10.1109/ojemb.2023.3256181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 02/06/2023] [Accepted: 03/09/2023] [Indexed: 03/14/2023] Open
Abstract
The drastic increase in the aging population has increased the prevalence of osteoarthritis in the United States. The ability to monitor symptoms of osteoarthritis (such as pain) within a free-living environment could improve understanding of each person's experiences with this disease and provide opportunities to personalize treatments specific to each person and their experience. In this work, localized knee tissue bioimpedance and self-reports of knee pain were collected from older adults ([Formula: see text]) with and without knee osteoarthritis over 7 days of free-living to evaluate if knee tissue bioimpedance is associated with persons' knee pain experience. Within the group of persons' with knee osteoarthritis increases in 128 kHz per-length resistance and decreases in 40 kHz per-length reactance were associated with increased probability of persons having active knee pain ([Formula: see text] and [Formula: see text]).
Collapse
Affiliation(s)
- Shelby Critcher
- Department of Electrical and Computer EngineeringThe University of AlabamaTuscaloosaAL35487USA
| | - Patricia Parmelee
- Department of PsychologyThe University of AlabamaTuscaloosaAL35487USA
| | - Todd J. Freeborn
- Department of Electrical and Computer EngineeringThe University of AlabamaTuscaloosaAL35487USA
| |
Collapse
|
4
|
Pîslaru-Dănescu L, Zărnescu GC, Telipan G, Stoica V. Design and Manufacturing of Equipment for Investigation of Low Frequency Bioimpedance. MICROMACHINES 2022; 13:1858. [PMID: 36363879 PMCID: PMC9698562 DOI: 10.3390/mi13111858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 10/22/2022] [Accepted: 10/25/2022] [Indexed: 06/16/2023]
Abstract
The purpose of this study was to highlight a method of making equipment for the investigation of low frequency bioimpedance. A constant current with an average value of I = 100 µA is injected into the human body via means of current injection electrodes, and the biological signal is taken from the electrodes of electric potential charged with the biopotentials generated by the human body. The resulting voltage, ΔU is processed by the electronic conditioning system. The mathematical model of the four-electrode system in contact with the skin, and considering a target organ, was simplified to a single equivalent impedance. The capacitive filter low passes down from the differential input of the first instrumentation amplifier together with the isolated capacitive barrier integrated in the precision isolated secondary amplifier and maintains the biological signal taken from the electrodes charged with the undistorted biopotentials generated by the human body. Mass loops are avoided, and any electric shocks or electrostatic discharges are prevented. In addition, for small amplitudes of the biological signal, electromagnetic interferences of below 100 Hz of the power supply network were eliminated by using an active fourth-order Bessel filtering module. The measurements performed for the low frequency of f = 100 Hz on the volunteers showed for the investigated organs that the bioelectrical resistivities vary from 90 Ωcm up to 450 Ωcm, and that these are in agreement with other published and disseminated results for each body zone.
Collapse
|
5
|
Ozmen GC, Nichols C, Mabrouk S, Berkebile J, Lan L, Inan OT. Wearable Mid-Activity Measurement of Lower Limb Electrical Bioimpedance Estimates Vertical Ground Reaction Force Features. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:91-94. [PMID: 36085606 DOI: 10.1109/embc48229.2022.9871267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In recent years, wearable mid-activity electrical bioimpedance (EBI) sensing has been used to non-invasively track changes in edema and swelling levels within human joints. While the physiological origin of the changes in mid-activity EBI measurements have been demonstrated, EBI waveform patterns during activity have not been explored. In this work, we present a novel approach to extract waveform features from EBI measurements during gait to estimate the changes in vertical ground reaction forces (vGRF) corresponding to fatigue. Wearable EBI and vGRF data were measured from six healthy subjects during an asymmetric fatiguing protocol. For the exercised leg, the first peak of vGRF corresponding to the initial phase of simple support, decreased significantly and the loading rate increased significantly between the beginning and the end of the protocol. No significant change in these parameters were observed for the control leg. The first peak of vGRF and loading rate during the protocol (15 walking sessions) were correlated to the multi-frequency EBI features with mean Pearson's r=0.81 and r=0.777, respectively. The results of this proof-of-concept study demonstrate the feasibility of estimating biomechanical parameters during activity with wearable EBI. Clinical Relevance - The proposed wearable system and associated signal processing could enable convenient tracking of changes in vGRFs during daily living activities, allowing physiotherapists and doctors to remotely monitor the progress and adherence of their patients and thereby reducing the number of clinical visits.
Collapse
|
6
|
Critcher S, Freeborn TJ. System Performance and User Feedback Regarding Wearable Bioimpedance System for Multi-Site Knee Tissue Monitoring: Free-Living Pilot Study With Healthy Adults. FRONTIERS IN ELECTRONICS 2022; 3. [PMID: 37096020 PMCID: PMC10122869 DOI: 10.3389/felec.2022.824981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Knee-focused wearable devices have the potential to support personalized rehabilitation therapies by monitoring localized tissue alterations related to activities that reduce functional symptoms and pain. However, supporting these applications requires reported data to be reliable and accurate which can be challenging in the unsupervised free-living conditions that wearable devices are deployed. This pilot study has assessed a knee-focused wearable sensor system to quantify 1) system performance (operation, rates of data artifacts, environment impacts) to estimate realistic targets for reliable data with this system and 2) user experiences (comfort, fit, usability) to help inform future designs to increase usability and adoption of knee-focused wearables. Study data was collected from five healthy adult participants over 2 days, with 84.5 and 35.9% of artifact free data for longitudinal and transverse electrode configurations. Small to moderate positive correlations were also identified between changes in resistance, temperature, and humidity with respect to acceleration to highlight how this system can be used to explore relationships between knee tissues and environmental/activity context.
Collapse
|
7
|
Ngo C, Munoz C, Lueken M, Hülkenberg A, Bollheimer C, Briko A, Kobelev A, Shchukin S, Leonhardt S. A Wearable, Multi-Frequency Device to Measure Muscle Activity Combining Simultaneous Electromyography and Electrical Impedance Myography. SENSORS 2022; 22:s22051941. [PMID: 35271088 PMCID: PMC8914780 DOI: 10.3390/s22051941] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/22/2022] [Accepted: 02/26/2022] [Indexed: 01/24/2023]
Abstract
The detection of muscle contraction and the estimation of muscle force are essential tasks in robot-assisted rehabilitation systems. The most commonly used method to investigate muscle contraction is surface electromyography (EMG), which, however, shows considerable disadvantages in predicting the muscle force, since unpredictable factors may influence the detected force but not necessarily the EMG data. Electrical impedance myography (EIM) investigates the change in electrical impedance during muscle activities and is another promising technique to investigate muscle functions. This paper introduces the design, development, and evaluation of a device that performs EMG and EIM simultaneously for more robust measurement of muscle conditions subject to artifacts. The device is light, wearable, and wireless and has a modular design, in which the EMG, EIM, micro-controller, and communication modules are stacked and interconnected through connectors. As a result, the EIM module measures the bioimpedance between 20 and 200 Ω with an error of less than 5% at 140 SPS. The settling time during the calibration phase of this module is less than 1000 ms. The EMG module captures the spectrum of the EMG signal between 20–150 Hz at 1 kSPS with an SNR of 67 dB. The micro-controller and communication module builds an ARM-Cortex M3 micro-controller which reads and transfers the captured data every 1 ms over RF (868 Mhz) with a baud rate of 500 kbps to a receptor connected to a PC. Preliminary measurements on a volunteer during leg extension, walking, and sit-to-stand showed the potential of the system to investigate muscle function by combining simultaneous EMG and EIM.
Collapse
Affiliation(s)
- Chuong Ngo
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany; (C.M.); (M.L.); (A.H.); (S.L.)
- Correspondence: ; Tel.: +49-241-8023513
| | - Carlos Munoz
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany; (C.M.); (M.L.); (A.H.); (S.L.)
| | - Markus Lueken
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany; (C.M.); (M.L.); (A.H.); (S.L.)
| | - Alfred Hülkenberg
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany; (C.M.); (M.L.); (A.H.); (S.L.)
| | | | - Andrey Briko
- Department of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, Russia; (A.B.); (A.K.); (S.S.)
| | - Alexander Kobelev
- Department of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, Russia; (A.B.); (A.K.); (S.S.)
| | - Sergey Shchukin
- Department of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, Russia; (A.B.); (A.K.); (S.S.)
| | - Steffen Leonhardt
- Medical Information Technology, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany; (C.M.); (M.L.); (A.H.); (S.L.)
| |
Collapse
|
8
|
Bioelectrical Impedance Vector and Creatine Phosphokinase Changes Induced by a High-Intensity Training Session in Rink Hockey Players. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12020751] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
This study aimed to analyze anthropometric and whole-body/muscle-localized bioelectrical impedance vector analysis (BIVA) adaptations and their relation to creatine kinase (CK) as a biomarker of muscle damage in a group of seven male players in the maximum category of professional rink hockey. There were three checkpoint assessments in relation to a high-intensity training session: pre-session (PRE), post-session (POST), and 24 h-post-session (POST24H). The resistance, reactance, and impedance module were adjusted by height (R/h, Xc/h, and Z/h, respectively). The Wilcoxon signed-rank test was used to compare the data at baseline and follow-up, while Spearman correlation was used to explore the relationship between CK and the rest of the parameters. The results registered a decrease in body mass at POST (p = 0.03) and a reestablishment at POST24H (p = 0.02). Whole-body BIVA registered a significant increase in R/h between PRE–to–POST (p = 0.02) and returned to baseline values at POST24H (p = 0.02), which was expected since this parameter is related to hydration processes. Muscle-localized BIVA in the rectus femoris muscle showed an increase in both Xc/h and phase angle in POST (p = 0.04 and p = 0.03, respectively) and a decrease in Xc/h at POST24H (p = 0.02). CK correlated with R/h in the rectus femoris at all the checkpoints (PRE–to–POST: r = 0.75, p = 0.05; PRE–to–POST24H: r = 0.81, p = 0.03; POST–to–POST24H: r = 0.82, p = 0.02). Our results indicate that BIVA is a sensitive methodology to assess general and muscle-localized hydration induced by a high-intensity training session in rink hockey players. A correlation between BIVA and CK was also reported.
Collapse
|
9
|
Critcher S, Freeborn TJ. Flexible PCB Failures From Dynamic Activity and Their Impacts on Bioimpedance Measurements: A Wearable Case Study. IEEE OPEN JOURNAL OF CIRCUITS AND SYSTEMS 2021; 2:732-742. [PMID: 34901875 PMCID: PMC8656411 DOI: 10.1109/ojcas.2021.3122369] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Wearable health monitoring systems that collect data in free-living environments are becoming increasingly popular. Flexible printed circuits provide a commercially available option that can conform to the shape of a wearable system and support electronic sensing and flexible interconnect. However, repetitive dynamic activity can stress and damage the interconnect of flexible PCBs which degrades data quality. This case study evaluated the performance of flexible PCBs providing interconnect between electrodes and sensing electronics for tissue bioimpedance measurements in a wearable system. Resistance data (1 kHz to 128 kHz) was collected from localized knee tissues of 3 participants using the wearable design with flexible PCBs over 7 days of free-living. From electrical and optical inspection after use trace cracking of the flexible PCBs occurred, degrading tissue resistances reported by the wearable system. Exploration of these results advances understanding of how flexible PCBs perform in free-living conditions for wearable bioimpedance applications.
Collapse
Affiliation(s)
- Shelby Critcher
- Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35487, USA
| | - Todd J Freeborn
- Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35487, USA
| |
Collapse
|
10
|
Freeborn TJ, Critcher S. Threshold and Trend Artifacts in Localized Multi-Frequency Bioimpedance Measurements. IFAC-PAPERSONLINE 2021; 54:55-60. [PMID: 37097809 PMCID: PMC10122868 DOI: 10.1016/j.ifacol.2021.10.231] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Localized tissue bioimpedance is being widely investigated as a technique to identify physiological features in support of health focused applications. In support of this method being translated into wearable systems for continuous monitoring, it is critical to not only collect measurements but also evaluate their quality. This is necessary to reduce errors in equipment or measurement conditions from contributing data artifacts to datasets that will be analyzed. Two methods for artifact identification in resistance measurements of bioimpedance datasets are presented. These methods, based on thresholding and trend detection, are applied to localized knee bioimpedance datasets collected from two knee sites over 7 consecutive days in free-living conditions. Threshold artifacts were identified in 0.04% (longitudinal and transverse) and 0.69% (longitudinal) /3.50% (transverse) of the total data collected.
Collapse
Affiliation(s)
- Todd J Freeborn
- Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35404 USA
| | - Shelby Critcher
- Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35404 USA
| |
Collapse
|
11
|
Cebrián-Ponce Á, Irurtia A, Carrasco-Marginet M, Saco-Ledo G, Girabent-Farrés M, Castizo-Olier J. Electrical Impedance Myography in Health and Physical Exercise: A Systematic Review and Future Perspectives. Front Physiol 2021; 12:740877. [PMID: 34594243 PMCID: PMC8476966 DOI: 10.3389/fphys.2021.740877] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 08/19/2021] [Indexed: 12/25/2022] Open
Abstract
Background: Electrical impedance myography (EIM) is a non-invasive method that provides information about muscle health and changes that occur within it. EIM is based on the analysis of three impedance variables: resistance, reactance, and the phase angle. This systematic review of the literature provides a deeper insight into the scope and range of applications of EIM in health and physical exercise. The main goal of this work was to systematically review the studies on the applications of EIM in health and physical exercise in order to summarize the current knowledge on this method and outline future perspectives in this growing area, including a proposal for a research agenda. Furthermore, some basic assessment principles are provided. Methods: Systematic literature searches on PubMed, Scopus, SPORTDiscus and Web of Science up to September 2020 were conducted on any empirical investigations using localized bioimpedance devices to perform EIM within health and physical exercise contexts. The search included healthy individuals, elite soccer players with skeletal muscle injury, and subjects with primary sarcopenia. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist was used to develop the systematic review protocol. The quality and risk of bias of the studies included were assessed with the AQUA tool. Results: Nineteen eligible original articles were included in this review, which were separated into three tables according to the nature of the study. The first table includes six studies on the bioelectrical characterization of muscle. The second table includes five studies analyzing muscle changes in injured elite soccer players. The third table includes studies on the short-, medium-, and long-term bioelectrical adaptations to physical exercise. Conclusions: EIM has been used for the evaluation of the muscle condition in the clinical field over the last few years, especially in different neuromuscular diseases. It can also play an important role in other contexts as an alternative to complex and expensive methods such as magnetic resonance imaging. However, further research is needed. The main step in establishing EIM as a valid tool in the scientific field is to standardize the protocol for performing impedance assessments.
Collapse
Affiliation(s)
- Álex Cebrián-Ponce
- Barcelona Sports Sciences Research Group, Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona (UB), Barcelona, Spain
| | - Alfredo Irurtia
- Barcelona Sports Sciences Research Group, Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Carrasco-Marginet
- Barcelona Sports Sciences Research Group, Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona (UB), Barcelona, Spain
| | - Gonzalo Saco-Ledo
- Bioenergy and Motion Analysis Laboratory, National Research Center on Human Evolution (CENIEH), Burgos, Spain
| | | | | |
Collapse
|
12
|
Localized Bioimpedance Measurements with the MAX3000x Integrated Circuit: Characterization and Demonstration. SENSORS 2021; 21:s21093013. [PMID: 33923037 PMCID: PMC8123364 DOI: 10.3390/s21093013] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 04/15/2021] [Accepted: 04/20/2021] [Indexed: 01/24/2023]
Abstract
The commercial availability of integrated circuits with bioimpedance sensing functionality is advancing the opportunity for practical wearable systems that monitor the electrical impedance properties of tissues to identify physiological features in support of health-focused applications. This technical note characterizes the performance of the MAX3000x (resistance/reactance accuracy, power modes, filtering, gains) and is available for on-board processing (electrode detection) for localized bioimpedance measurements. Measurements of discrete impedances that are representative of localized tissue bioimpedance support that this IC has a relative error of <10% for the resistance component of complex impedance measurements, but can also measure relative alterations in the 250 mΩ range. The application of the MAX3000x for monitoring localized bicep tissues during activity is presented to highlight its functionality, as well as its limitations, for multi-frequency measurements. This device is a very-small-form-factor single-chip solution for measuring multi-frequency bioimpedance with significant on-board processing with potential for wearable applications.
Collapse
|
13
|
Mabrouk S, Whittingslow D, Inan OT. Robust Method for Mid-Activity Tracking and Evaluation of Ankle Health Post-Injury. IEEE Trans Biomed Eng 2021; 68:1341-1350. [PMID: 32997618 DOI: 10.1109/tbme.2020.3027477] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE To present a robust methodology for evaluating ankle health during ambulation using a wearable device. Methods: We developed a novel data capture system that leverages changes within the ankle during ambulation for real-time tracking of bioimpedance. The novel analysis compares the range of reactance at 5 kHz to the range of reactance at 100 kHz; which removes the technique's previous reliance on a known baseline. To aid in interpretation of the measurements, we developed a quantitative simulation model based on a literature review of the effects on joint bioimpedance of variations in edematous fluid volume, muscle fiber tears, and blood flow changes. Results: The results of the simulation predicted a significant difference in the ratio of the range of the reactance from 5 kHz to 100 kHz between the healthy and injured ankles. These results were validated in 15 subjects - with 11 healthy ankles and 7 injured ankles measured. The injured subjects had lateral ankle sprains 2-4 weeks prior to the measurement. The analysis technique differentiated between the healthy and the injured population (p<<0.01), and a correlation (R = 0.8) with a static protocol previously validated for its sensitivity to edema. Conclusion: The technology presented can detect variations in ankle edema and structural integrity of ankles, and thus could provide valuable feedback to clinicians and patients during the rehabilitation of an ankle injury. Significance: This technology could lead to better-informed decision making regarding a patient's readiness to return to activity and / or tailoring rehabilitation activities to an individual's changing needs.
Collapse
|
14
|
Honorato RDC, Ferraz ASM, Kassiano W, Carvalho DP, Ceccatto VM. Test-retest reliability of electrical impedance myography in hamstrings of healthy young men. J Electromyogr Kinesiol 2021; 56:102511. [PMID: 33454538 DOI: 10.1016/j.jelekin.2020.102511] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/22/2020] [Accepted: 12/30/2020] [Indexed: 11/16/2022] Open
Abstract
Several techniques are available to assess muscle tissue status, including electrical impedance myography (EIM). Despite being used in the assessment of neuromuscular status in injury and response to exercise, reliability data for hamstrings muscles are limited. Therefore, this study aimed to determine the test-retest reliability of EIM components on hamstrings. Twenty-one healthy males (25.3 ± 3.4 years; 173 ± 6.7 cm; and 79.7 ± 15.9 kg) volunteered for this study. Subjects completed two visits, separated by seven days to collect EIM components (resistance, reactance, impedance, and phase angle) in the longitudinal and transversal axis of hamstrings in both thighs, using a bioimpedance device and Ag/AgCL adhesive contact electrodes. The electrode arrangement was in the muscular belly, half the distance between origin and insertion of the hamstrings. Reliability was determined by the intraclass correlation coefficient (ICC), minimal detectable change (MDC), and Bland-Altman plots. We observed high to excellent reliability (ICC > 0.85) between all EIM components, except for reactance with MDC ranged from 2.0 to 10.8 and the mean bias in Bland-Altman plots ranged from -0.02 to 2.48 (95% limits of agreement from -9.98 to 11.20). From our findings, the hamstrings assessment using EIM technique is reliable to assess muscle tissue; therefore, it enables the evaluation of changes/adaptations in clinical and applied contexts.
Collapse
Affiliation(s)
- Renêe de Caldas Honorato
- Sports Department, Pará State University, Belém, Brazil; Northeast Biotechnology Network, Postgraduate Program in Biotechnology, Ceará State University, Fortaleza, Brazil.
| | - Alex Soares Marreiros Ferraz
- Biotechnology and Exercise Biology Research Laboratory, Institute of Physical Education and Sports, Federal University of Ceará, Fortaleza, Brazil
| | - Witalo Kassiano
- Metabolism, Nutrition and Exercise Laboratory, Physical Education and Sport Center, Londrina State University, Londrina, Brazil.
| | - Denise Pires Carvalho
- Endocrine Physiology Doris Rosenthal Research Laboratory, Institute of Biophysical Carlos Chagas Filho, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Vânia Marilande Ceccatto
- Northeast Biotechnology Network, Postgraduate Program in Biotechnology, Ceará State University, Fortaleza, Brazil; Biochemistry and Gene Expression Research Laboratory, Superior Institute of Biomedical Science, Ceará State University, Fortaleza, Brazil
| |
Collapse
|
15
|
Fu B, Freeborn TJ. Cole-impedance parameters representing biceps tissue bioimpedance in healthy adults and their alterations following eccentric exercise. J Adv Res 2020; 25:285-293. [PMID: 32922994 PMCID: PMC7474209 DOI: 10.1016/j.jare.2020.05.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Revised: 05/13/2020] [Accepted: 05/14/2020] [Indexed: 12/14/2022] Open
Abstract
The purpose of this study is to identify if participation in an eccentric exercise protocol altered the Cole-impedance model parameters that represent localized bicep tissue bioimpedance. This supports continued efforts to identify which features of tissue bioimpedance may be effective markers to non-invasively identify skeletal muscle damage. Here, the Cole-impedance model parameters that best fit the localized electrical impedance of exercised (using an eccentric stimulus) and unexercised biceps of 6 participants (collected before, immediately after and at 24 h, 48 h, 72 h and 96 h) are determined using a numerical optimization technique. Statistical tests comparing the pre-exercise and post-exercise model parameters report significant decreases in R ∞ and R 1 with significant increases in C at 72 h and 96 h post-exercise for exercised biceps (aligning with noted periods of peak swelling). These changes in R ∞ , R 1 , and C were not observed in the unexercised biceps. These results support that the C parameter of the Cole-impedance model fit to bioimpedance data may be a suitable marker for identifying skeletal muscle damage.
Collapse
Affiliation(s)
- Bo Fu
- Dept. Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, USA
| | - Todd J Freeborn
- Dept. Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, USA
| |
Collapse
|
16
|
Mabrouk S, Hersek S, Jeong HK, Whittingslow D, Ganti VG, Wolkoff P, Inan OT. Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy. IEEE Trans Biomed Eng 2019; 67:1019-1029. [PMID: 31295102 DOI: 10.1109/tbme.2019.2927807] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS). METHODS We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema. This technique addresses many of the major challenges in longitudinal BIS-based edema assessment, including day-to-day variability in electrode placement, positional/postural variability, and intersubject variability. RESULTS We first evaluated the hardware in bench-top testing, and determined the error of the bioimpedance measurements to be 0.4 Ω for the real components and 0.54 Ω for the imaginary components with a resolution of 0.2 Ω. We then validated the hardware and differential measurement technique in: 1) an ex vivo, fresh-frozen, cadaveric limb model, and 2) a cohort of 11 human subjects for proof of concept (eight healthy controls and five subjects with recently acquired acute unilateral ankle injury). CONCLUSION The hardware design, with novel calibration methodology, and differential measurement technique can potentially enable long-term quantification of ankle edema throughout the course of rehabilitation following acute ankle injuries. SIGNIFICANCE This could lead to better-informed decision making regarding readiness to return to activities and/or tailoring of rehabilitation activities to an individual's changing needs.
Collapse
|
17
|
Freeborn TJ, Fu B. Time-course bicep tissue bio-impedance changes throughout a fatiguing exercise protocol. Med Eng Phys 2019; 69:109-115. [PMID: 31056402 DOI: 10.1016/j.medengphy.2019.04.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 03/19/2019] [Accepted: 04/09/2019] [Indexed: 12/14/2022]
Abstract
This study investigated the localized electrical-impedance changes in the biceps tissues throughout a fatiguing exercise protocol. During the protocol, 17 subjects performed 10 sets of bicep curl repetitions at either 60% or 75% of their one-repetition maximum weight until task failure. The localized tissue impedance (resistance, reactance, phase angle) was measured at 10 kHz, 50 kHz, and 100 kHz immediately after each of 10 sets for comparison against the baseline pre-fatigue measures. A trend of decreasing resistance and reactance magnitude were observed, with greater changes occurring as the protocol progressed. Statistical testing demonstrated statistically significant changes in resistance, reactance, and phase angle for both groups of participants. The significant changes in resistance were observed at earlier time-points than the reactance and phase angle changes for both groups.
Collapse
Affiliation(s)
- Todd J Freeborn
- Department of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL 35487, USA.
| | - Bo Fu
- Department of Electrical and Computer Engineering, The University of Alabama, Tuscaloosa, AL 35487, USA
| |
Collapse
|
18
|
Design and Evaluation of an Electrical Bioimpedance Device Based on DIBS for Myography during Isotonic Exercises. JOURNAL OF LOW POWER ELECTRONICS AND APPLICATIONS 2018. [DOI: 10.3390/jlpea8040050] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Electrical Bioimpedance Spectroscopy (EIS) is a technique used to assess passive electrical properties of biological materials. EIS detects physiological and pathological conditions in animal tissues. Recently, the introduction of broadband excitation signals has reduced the measuring time for application techniques such as Electrical Bioimpedance Myography. Therefore, this work is aimed at proposing a prototype by using discrete interval binary sequences (DIBS), which is based on a system that holds a current source, impedance acquisition system, microcontroller and graphical user interface. Measurements between 5 Ω to 5 kΩ had impedance acquisition and phase angle errors of aproximately 2% and were lower than 3 degrees, respectively. Based on a proposed circuit, bioimpedance of the chest muscle (Pectoralis Major) was measured during isotonic exercise (push-up). As a result, our analyses have detected tiredness and fatigue. We have explored and proposed new parameters which assess such conditions, as both the maximum magnitude and tiredness coefficient. These parameters decrease exponentially with consecutive push-ups and were convergent in the majority of the sixteen days of measurement.
Collapse
|
19
|
Fatigue-Induced Cole Electrical Impedance Model Changes of Biceps Tissue Bioimpedance. FRACTAL AND FRACTIONAL 2018. [DOI: 10.3390/fractalfract2040027] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Bioimpedance, or the electrical impedance of biological tissues, describes the passive electrical properties of these materials. To simplify bioimpedance datasets, fractional-order equivalent circuit presentations are often used, with the Cole-impedance model being one of the most widely used fractional-order circuits for this purpose. In this work, bioimpedance measurements from 10 kHz to 100 kHz were collected from participants biceps tissues immediately prior and immediately post completion of a fatiguing exercise protocol. The Cole-impedance parameters that best fit these datasets were determined using numerical optimization procedures, with relative errors of within approximately ± 0.5 % and ± 2 % for the simulated resistance and reactance compared to the experimental data. Comparison between the pre and post fatigue Cole-impedance parameters shows that the R ∞ , R 1 , and f p components exhibited statistically significant mean differences as a result of the fatigue induced changes in the study participants.
Collapse
|