1
|
Deep transfer learning: a novel glucose prediction framework for new subjects with type 2 diabetes. COMPLEX INTELL SYST 2022. [DOI: 10.1007/s40747-021-00360-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
AbstractBlood glucose (BG) prediction is an effective approach to avoid hyper- and hypoglycemia, and achieve intelligent glucose management for patients with type 1 or serious type 2 diabetes. Recent studies have tended to adopt deep learning networks to obtain improved prediction models and more accurate prediction results, which have often required significant quantities of historical continuous glucose-monitoring (CGM) data. However, for new patients with limited historical dataset, it becomes difficult to establish an acceptable deep learning network for glucose prediction. Consequently, the goal of this study was to design a novel prediction framework with instance-based and network-based deep transfer learning for cross-subject glucose prediction based on segmented CGM time series. Taking the effects of biodiversity into consideration, dynamic time warping (DTW) was applied to determine the proper source domain dataset that shared the greatest degree of similarity for new subjects. After that, a network-based deep transfer learning method was designed with cross-domain dataset to obtain a personalized model combined with improved generalization capability. In a case study, the clinical dataset demonstrated that, with additional segmented dataset from other subjects, the proposed deep transfer learning framework achieved more accurate glucose predictions for new subjects with type 2 diabetes.
Collapse
|
2
|
|
3
|
Shirin A, Della Rossa F, Klickstein I, Russell J, Sorrentino F. Optimal regulation of blood glucose level in Type I diabetes using insulin and glucagon. PLoS One 2019; 14:e0213665. [PMID: 30893335 PMCID: PMC6426249 DOI: 10.1371/journal.pone.0213665] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 02/26/2019] [Indexed: 12/11/2022] Open
Abstract
The Glucose-Insulin-Glucagon nonlinear model accurately describes how the body responds to exogenously supplied insulin and glucagon in patients affected by Type I diabetes. Based on this model, we design infusion rates of either insulin (monotherapy) or insulin and glucagon (dual therapy) that can optimally maintain the blood glucose level within desired limits after consumption of a meal and prevent the onset of both hypoglycemia and hyperglycemia. This problem is formulated as a nonlinear optimal control problem, which we solve using the numerical optimal control package PSOPT. Interestingly, in the case of monotherapy, we find the optimal solution is close to the standard method of insulin based glucose regulation, which is to assume a variable amount of insulin half an hour before each meal. We also find that the optimal dual therapy (that uses both insulin and glucagon) is better able to regulate glucose as compared to using insulin alone. We also propose an ad-hoc rule for both the dosage and the time of delivery of insulin and glucagon.
Collapse
Affiliation(s)
- Afroza Shirin
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
- * E-mail:
| | - Fabio Della Rossa
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| | - Isaac Klickstein
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| | - John Russell
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| | - Francesco Sorrentino
- Mechanical Engineering Department, University of New Mexico, Albuquerque, NM 87131, United States of America
| |
Collapse
|
4
|
Rigla M, García-Sáez G, Pons B, Hernando ME. Artificial Intelligence Methodologies and Their Application to Diabetes. J Diabetes Sci Technol 2018; 12:303-310. [PMID: 28539087 PMCID: PMC5851211 DOI: 10.1177/1932296817710475] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
In the past decade diabetes management has been transformed by the addition of continuous glucose monitoring and insulin pump data. More recently, a wide variety of functions and physiologic variables, such as heart rate, hours of sleep, number of steps walked and movement, have been available through wristbands or watches. New data, hydration, geolocation, and barometric pressure, among others, will be incorporated in the future. All these parameters, when analyzed, can be helpful for patients and doctors' decision support. Similar new scenarios have appeared in most medical fields, in such a way that in recent years, there has been an increased interest in the development and application of the methods of artificial intelligence (AI) to decision support and knowledge acquisition. Multidisciplinary research teams integrated by computer engineers and doctors are more and more frequent, mirroring the need of cooperation in this new topic. AI, as a science, can be defined as the ability to make computers do things that would require intelligence if done by humans. Increasingly, diabetes-related journals have been incorporating publications focused on AI tools applied to diabetes. In summary, diabetes management scenarios have suffered a deep transformation that forces diabetologists to incorporate skills from new areas. This recently needed knowledge includes AI tools, which have become part of the diabetes health care. The aim of this article is to explain in an easy and plane way the most used AI methodologies to promote the implication of health care providers-doctors and nurses-in this field.
Collapse
Affiliation(s)
- Mercedes Rigla
- Endocrinology and Nutrition Department, Parc Tauli University Hospital, Sabadell, Spain
- Mercedes Rigla, MD, PhD, Endocrinology and Nutrition Department, Parc Tauli University Hospital, I3PT, Autonomous University of Barcelona, Parc Taulí, 1, Sabadell, 08208, Spain.
| | - Gema García-Sáez
- Bioengineering and Telemedicine Centre, Universidad Politécnica de Madrid, Spain
- CIBER-BBN: Networking Research Centre for Bioengineering, Biomaterials and Nanomedicine, Madrid, Spain
| | - Belén Pons
- Endocrinology and Nutrition Department, Parc Tauli University Hospital, Sabadell, Spain
| | - Maria Elena Hernando
- Bioengineering and Telemedicine Centre, Universidad Politécnica de Madrid, Spain
- CIBER-BBN: Networking Research Centre for Bioengineering, Biomaterials and Nanomedicine, Madrid, Spain
| |
Collapse
|
5
|
Weisman A, Bai JW, Cardinez M, Kramer CK, Perkins BA. Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials. Lancet Diabetes Endocrinol 2017; 5:501-512. [PMID: 28533136 DOI: 10.1016/s2213-8587(17)30167-5] [Citation(s) in RCA: 304] [Impact Index Per Article: 43.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 04/11/2017] [Accepted: 04/11/2017] [Indexed: 12/27/2022]
Abstract
BACKGROUND Closed-loop artificial pancreas systems have been in development for several years, including assessment in numerous varied outpatient clinical trials. We aimed to summarise the efficacy and safety of artificial pancreas systems in outpatient settings and explore the clinical and technical factors that can affect their performance. METHODS We did a systematic review and meta-analysis of randomised controlled trials comparing artificial pancreas systems (insulin only or insulin plus glucagon) with conventional pump therapy (continuous subcutaneous insulin infusion [CSII] with blinded continuous glucose monitoring [CGM] or unblinded sensor-augmented pump [SAP] therapy) in adults and children with type 1 diabetes. We searched Medline, Embase, and the Cochrane Central Register of Controlled Trials for studies published from 1946, to Jan 1, 2017. We excluded studies not published in English, those involving pregnant women or participants who were in hospital, and those testing adjunct medications other than glucagon. The primary outcome was the mean difference in percentage of time blood glucose concentration remained in target range (3·9-10 mmol/L or 3·9-8 mmol/L, depending on the study), assessed by random-effects meta-analysis. This study is registered with PROSPERO, number 2015:CRD42015026854. FINDINGS We identified 984 reports; after exclusions, 27 comparisons from 24 studies (23 crossover and one parallel design) including a total of 585 participants (219 in adult studies, 265 in paediatric studies, and 101 in combined studies) were eligible for analysis. Five comparisons assessed dual-hormone (insulin and glucagon), two comparisons assessed both dual-hormone and single-hormone (insulin only), and 20 comparisons assessed single-hormone artificial pancreas systems. Time in target was 12·59% higher with artificial pancreas systems (95% CI 9·02-16·16; p<0·0001), from a weighted mean of 58·21% for conventional pump therapy (I2=84%). Dual-hormone artificial pancreas systems were associated with a greater improvement in time in target range compared with single-hormone systems (19·52% [95% CI 15·12-23·91] vs 11·06% [6·94 to 15·18]; p=0·006), although six of seven comparisons compared dual-hormone systems to CSII with blinded CGM, whereas 21 of 22 single-hormone comparisons had SAP as the comparator. Single-hormone studies had higher heterogeneity than dual-hormone studies (I2 79% vs 66%). Bias assessment characteristics were incompletely reported in 12 of 24 studies, no studies masked participants to the intervention assignment, and masking of outcome assessment was not done in 12 studies and was unclear in 12 studies. INTERPRETATION Artificial pancreas systems uniformly improved glucose control in outpatient settings, despite heterogeneous clinical and technical factors. FUNDING None.
Collapse
Affiliation(s)
- Alanna Weisman
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada; Division of Endocrinology and Metabolism, Department of Medicine, University of Toronto, Toronto, ON, Canada.
| | - Johnny-Wei Bai
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada
| | - Marina Cardinez
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada
| | - Caroline K Kramer
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada; Division of Endocrinology and Metabolism, Department of Medicine, University of Toronto, Toronto, ON, Canada
| | - Bruce A Perkins
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada; Division of Endocrinology and Metabolism, Department of Medicine, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
6
|
Turksoy K, Frantz N, Quinn L, Dumin M, Kilkus J, Hibner B, Cinar A, Littlejohn E. Automated Insulin Delivery-The Light at the End of the Tunnel. J Pediatr 2017; 186:17-28.e9. [PMID: 28396030 DOI: 10.1016/j.jpeds.2017.02.055] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 02/13/2017] [Accepted: 02/20/2017] [Indexed: 12/28/2022]
Affiliation(s)
- Kamuran Turksoy
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL
| | - Nicole Frantz
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL
| | - Laurie Quinn
- College of Nursing, University of Illinois at Chicago, Chicago, IL
| | - Magdalena Dumin
- Biological Sciences Division, University of Chicago, Chicago, IL
| | - Jennifer Kilkus
- Biological Sciences Division, University of Chicago, Chicago, IL
| | - Brooks Hibner
- Biological Sciences Division, University of Chicago, Chicago, IL
| | - Ali Cinar
- Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL; Biological Sciences Division, University of Chicago, Chicago, IL; Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL
| | | |
Collapse
|
7
|
Christiansen SC, Fougner AL, Stavdahl Ø, Kölle K, Ellingsen R, Carlsen SM. A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach. Diabetes Ther 2017; 8:489-506. [PMID: 28503717 PMCID: PMC5446388 DOI: 10.1007/s13300-017-0263-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Indexed: 01/01/2023] Open
Abstract
INTRODUCTION Patients with diabetes type 1 (DM1) struggle daily to achieve good glucose control. The last decade has seen a rush of research groups working towards an artificial pancreas (AP) through the application of a double subcutaneous approach, i.e., subcutaneous (SC) continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion. Few have focused on the fundamental limitations of this approach, especially regarding outcome measures beyond time in range. METHODS Based on insulin physiology, the limitations of CGM, SC insulin absorption, meal challenge, and physical activity in DM1 patients, we discuss the limitations of the double SC approach. Finally, we discuss safety measures and the achievements reported in some recent AP studies that have utilized the double SC approach. RESULTS Most studies show that a double SC AP increases the time in range compared to a sensor-augmented insulin pump and shortens the time in hypoglycemia. Despite these achievements, the proportion of time spent in hyperglycemia is still roughly 20-40%, and hypoglycemia is still present 1-4% of the time. The main factors limiting further progress are the latency of SC CGM (at least 5-10 min) and the slow pharmacokinetics of SC-delivered fast-acting insulin. The maximum blood insulin level is reached after 45 min and the maximum glucose-lowering effect is observed after 1.5-2 h, while the glucose-lowering effect lasts for at least 5 h. CONCLUSIONS Although using a double SC AP leads to significant improvements in glucose control, the SC approach has severe limitations that hamper further progress towards a robust AP.
Collapse
Affiliation(s)
- Sverre Christian Christiansen
- Department of Endocrinology, St Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
- Department of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology (NTNU), Trondheim, Norway.
| | - Anders Lyngvi Fougner
- Department of Engineering Cybernetics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
- Central Norway Regional Health Authority, Stjørdal, Norway
| | - Øyvind Stavdahl
- Department of Engineering Cybernetics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Konstanze Kölle
- Department of Engineering Cybernetics, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
- Central Norway Regional Health Authority, Stjørdal, Norway
| | - Reinold Ellingsen
- Department of Electronic Systems, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Sven Magnus Carlsen
- Department of Endocrinology, St Olavs Hospital, Trondheim University Hospital, Trondheim, Norway
- Department of Cancer Research and Molecular Medicine, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
8
|
Oviedo S, Vehí J, Calm R, Armengol J. A review of personalized blood glucose prediction strategies for T1DM patients. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e2833. [PMID: 27644067 DOI: 10.1002/cnm.2833] [Citation(s) in RCA: 107] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 09/15/2016] [Accepted: 09/16/2016] [Indexed: 06/06/2023]
Abstract
This paper presents a methodological review of models for predicting blood glucose (BG) concentration, risks and BG events. The surveyed models are classified into three categories, and they are presented in summary tables containing the most relevant data regarding the experimental setup for fitting and testing each model as well as the input signals and the performance metrics. Each category exhibits trends that are presented and discussed. This document aims to be a compact guide to determine the modeling options that are currently being exploited for personalized BG prediction.
Collapse
Affiliation(s)
- Silvia Oviedo
- Institut d'Informàtica i Aplicacions, Parc Científic i Tecnològic de la Universitat de Girona, 17003, Girona, Spain
| | - Josep Vehí
- Institut d'Informàtica i Aplicacions, Universitat de Girona, Campus Montilivi, Edifici P4, 17071, Girona, Spain
| | - Remei Calm
- Institut d'Informàtica i Aplicacions, Universitat de Girona, Campus Montilivi, Edifici P4, 17071, Girona, Spain
| | - Joaquim Armengol
- Institut d'Informàtica i Aplicacions, Universitat de Girona, Campus Montilivi, Edifici P4, 17071, Girona, Spain
| |
Collapse
|
9
|
Pinsker JE, Lee JB, Dassau E, Seborg DE, Bradley PK, Gondhalekar R, Bevier WC, Huyett L, Zisser HC, Doyle FJ. Randomized Crossover Comparison of Personalized MPC and PID Control Algorithms for the Artificial Pancreas. Diabetes Care 2016; 39:1135-42. [PMID: 27289127 PMCID: PMC4915560 DOI: 10.2337/dc15-2344] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Accepted: 02/18/2016] [Indexed: 02/03/2023]
Abstract
OBJECTIVE To evaluate two widely used control algorithms for an artificial pancreas (AP) under nonideal but comparable clinical conditions. RESEARCH DESIGN AND METHODS After a pilot safety and feasibility study (n = 10), closed-loop control (CLC) was evaluated in a randomized, crossover trial of 20 additional adults with type 1 diabetes. Personalized model predictive control (MPC) and proportional integral derivative (PID) algorithms were compared in supervised 27.5-h CLC sessions. Challenges included overnight control after a 65-g dinner, response to a 50-g breakfast, and response to an unannounced 65-g lunch. Boluses of announced dinner and breakfast meals were given at mealtime. The primary outcome was time in glucose range 70-180 mg/dL. RESULTS Mean time in range 70-180 mg/dL was greater for MPC than for PID (74.4 vs. 63.7%, P = 0.020). Mean glucose was also lower for MPC than PID during the entire trial duration (138 vs. 160 mg/dL, P = 0.012) and 5 h after the unannounced 65-g meal (181 vs. 220 mg/dL, P = 0.019). There was no significant difference in time with glucose <70 mg/dL throughout the trial period. CONCLUSIONS This first comprehensive study to compare MPC and PID control for the AP indicates that MPC performed particularly well, achieving nearly 75% time in the target range, including the unannounced meal. Although both forms of CLC provided safe and effective glucose management, MPC performed as well or better than PID in all metrics.
Collapse
Affiliation(s)
| | - Joon Bok Lee
- William Sansum Diabetes Center, Santa Barbara, CA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA
| | - Eyal Dassau
- William Sansum Diabetes Center, Santa Barbara, CA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| | - Dale E Seborg
- William Sansum Diabetes Center, Santa Barbara, CA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA
| | | | - Ravi Gondhalekar
- William Sansum Diabetes Center, Santa Barbara, CA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA
| | | | - Lauren Huyett
- William Sansum Diabetes Center, Santa Barbara, CA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA
| | - Howard C Zisser
- William Sansum Diabetes Center, Santa Barbara, CA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA
| | - Francis J Doyle
- William Sansum Diabetes Center, Santa Barbara, CA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| |
Collapse
|
10
|
Trevitt S, Simpson S, Wood A. Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes: What Systems Are in Development? J Diabetes Sci Technol 2016; 10:714-23. [PMID: 26589628 PMCID: PMC5038530 DOI: 10.1177/1932296815617968] [Citation(s) in RCA: 89] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Closed-loop artificial pancreas device (APD) systems are externally worn medical devices that are being developed to enable people with type 1 diabetes to regulate their blood glucose levels in a more automated way. The innovative concept of this emerging technology is that hands-free, continuous, glycemic control can be achieved by using digital communication technology and advanced computer algorithms. METHODS A horizon scanning review of this field was conducted using online sources of intelligence to identify systems in development. The systems were classified into subtypes according to their level of automation, the hormonal and glycemic control approaches used, and their research setting. RESULTS Eighteen closed-loop APD systems were identified. All were being tested in clinical trials prior to potential commercialization. Six were being studied in the home setting, 5 in outpatient settings, and 7 in inpatient settings. It is estimated that 2 systems may become commercially available in the EU by the end of 2016, 1 during 2017, and 2 more in 2018. CONCLUSIONS There are around 18 closed-loop APD systems progressing through early stages of clinical development. Only a few of these are currently in phase 3 trials and in settings that replicate real life.
Collapse
Affiliation(s)
- Sara Trevitt
- NIHR Horizon Scanning Research & Intelligence Centre, University of Birmingham, Birmingham, UK
| | - Sue Simpson
- NIHR Horizon Scanning Research & Intelligence Centre, University of Birmingham, Birmingham, UK
| | - Annette Wood
- NIHR Horizon Scanning Research & Intelligence Centre, University of Birmingham, Birmingham, UK
| |
Collapse
|
11
|
Bartlett ST, Markmann JF, Johnson P, Korsgren O, Hering BJ, Scharp D, Kay TWH, Bromberg J, Odorico JS, Weir GC, Bridges N, Kandaswamy R, Stock P, Friend P, Gotoh M, Cooper DKC, Park CG, O'Connell P, Stabler C, Matsumoto S, Ludwig B, Choudhary P, Kovatchev B, Rickels MR, Sykes M, Wood K, Kraemer K, Hwa A, Stanley E, Ricordi C, Zimmerman M, Greenstein J, Montanya E, Otonkoski T. Report from IPITA-TTS Opinion Leaders Meeting on the Future of β-Cell Replacement. Transplantation 2016; 100 Suppl 2:S1-44. [PMID: 26840096 PMCID: PMC4741413 DOI: 10.1097/tp.0000000000001055] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2015] [Accepted: 10/07/2015] [Indexed: 12/11/2022]
Affiliation(s)
- Stephen T. Bartlett
- Department of Surgery, University of Maryland School of Medicine, Baltimore MD
| | - James F. Markmann
- Division of Transplantation, Massachusetts General Hospital, Boston MA
| | - Paul Johnson
- Nuffield Department of Surgical Sciences and Oxford Centre for Diabetes, Endocrinology, and Metabolism, University of Oxford, Oxford, United Kingdom
| | - Olle Korsgren
- Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| | - Bernhard J. Hering
- Schulze Diabetes Institute, Department of Surgery, University of Minnesota, Minneapolis, MN
| | - David Scharp
- Prodo Laboratories, LLC, Irvine, CA
- The Scharp-Lacy Research Institute, Irvine, CA
| | - Thomas W. H. Kay
- Department of Medicine, St. Vincent’s Hospital, St. Vincent's Institute of Medical Research and The University of Melbourne Victoria, Australia
| | - Jonathan Bromberg
- Division of Transplantation, Massachusetts General Hospital, Boston MA
| | - Jon S. Odorico
- Division of Transplantation, Department of Surgery, School of Medicine and Public Health, University of Wisconsin, Madison, WI
| | - Gordon C. Weir
- Joslin Diabetes Center and Harvard Medical School, Boston, MA
| | - Nancy Bridges
- National Institutes of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, MD
| | - Raja Kandaswamy
- Schulze Diabetes Institute, Department of Surgery, University of Minnesota, Minneapolis, MN
| | - Peter Stock
- Division of Transplantation, University of San Francisco Medical Center, San Francisco, CA
| | - Peter Friend
- Nuffield Department of Surgical Sciences and Oxford Centre for Diabetes, Endocrinology, and Metabolism, University of Oxford, Oxford, United Kingdom
| | - Mitsukazu Gotoh
- Department of Surgery, Fukushima Medical University, Fukushima, Japan
| | - David K. C. Cooper
- Thomas E. Starzl Transplantation Institute, University of Pittsburgh, Pittsburgh, PA
| | - Chung-Gyu Park
- Xenotransplantation Research Center, Department of Microbiology and Immunology, Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Korea
| | - Phillip O'Connell
- The Center for Transplant and Renal Research, Westmead Millennium Institute, University of Sydney at Westmead Hospital, Westmead, NSW, Australia
| | - Cherie Stabler
- Diabetes Research Institute, School of Medicine, University of Miami, Coral Gables, FL
| | - Shinichi Matsumoto
- National Center for Global Health and Medicine, Tokyo, Japan
- Otsuka Pharmaceutical Factory inc, Naruto Japan
| | - Barbara Ludwig
- Department of Medicine III, Technische Universität Dresden, Dresden, Germany
- Paul Langerhans Institute Dresden of Helmholtz Centre Munich at University Clinic Carl Gustav Carus of TU Dresden and DZD-German Centre for Diabetes Research, Dresden, Germany
| | - Pratik Choudhary
- Diabetes Research Group, King's College London, Weston Education Centre, London, United Kingdom
| | - Boris Kovatchev
- University of Virginia, Center for Diabetes Technology, Charlottesville, VA
| | - Michael R. Rickels
- Division of Endocrinology, Diabetes, and Metabolism, Department of Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA
| | - Megan Sykes
- Columbia Center for Translational Immunology, Coulmbia University Medical Center, New York, NY
| | - Kathryn Wood
- Nuffield Department of Surgical Sciences and Oxford Centre for Diabetes, Endocrinology, and Metabolism, University of Oxford, Oxford, United Kingdom
| | - Kristy Kraemer
- National Institutes of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, MD
| | - Albert Hwa
- Juvenile Diabetes Research Foundation, New York, NY
| | - Edward Stanley
- Murdoch Children's Research Institute, Parkville, VIC, Australia
- Monash University, Melbourne, VIC, Australia
| | - Camillo Ricordi
- Diabetes Research Institute, School of Medicine, University of Miami, Coral Gables, FL
| | - Mark Zimmerman
- BetaLogics, a business unit in Janssen Research and Development LLC, Raritan, NJ
| | - Julia Greenstein
- Discovery Research, Juvenile Diabetes Research Foundation New York, NY
| | - Eduard Montanya
- Bellvitge Biomedical Research Institute (IDIBELL), Hospital Universitari Bellvitge, CIBER of Diabetes and Metabolic Diseases (CIBERDEM), University of Barcelona, Barcelona, Spain
| | - Timo Otonkoski
- Children's Hospital and Biomedicum Stem Cell Center, University of Helsinki, Helsinki, Finland
| |
Collapse
|
12
|
Brugués A, Bromuri S, Barry M, Del Toro ÓJ, Mazurkiewicz MR, Kardas P, Pegueroles J, Schumacher M. Processing Diabetes Mellitus Composite Events in MAGPIE. J Med Syst 2015; 40:44. [PMID: 26590982 DOI: 10.1007/s10916-015-0377-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Accepted: 10/09/2015] [Indexed: 10/22/2022]
Abstract
The focus of this research is in the definition of programmable expert Personal Health Systems (PHS) to monitor patients affected by chronic diseases using agent oriented programming and mobile computing to represent the interactions happening amongst the components of the system. The paper also discusses issues of knowledge representation within the medical domain when dealing with temporal patterns concerning the physiological values of the patient. In the presented agent based PHS the doctors can personalize for each patient monitoring rules that can be defined in a graphical way. Furthermore, to achieve better scalability, the computations for monitoring the patients are distributed among their devices rather than being performed in a centralized server. The system is evaluated using data of 21 diabetic patients to detect temporal patterns according to a set of monitoring rules defined. The system's scalability is evaluated by comparing it with a centralized approach. The evaluation concerning the detection of temporal patterns highlights the system's ability to monitor chronic patients affected by diabetes. Regarding the scalability, the results show the fact that an approach exploiting the use of mobile computing is more scalable than a centralized approach. Therefore, more likely to satisfy the needs of next generation PHSs. PHSs are becoming an adopted technology to deal with the surge of patients affected by chronic illnesses. This paper discusses architectural choices to make an agent based PHS more scalable by using a distributed mobile computing approach. It also discusses how to model the medical knowledge in the PHS in such a way that it is modifiable at run time. The evaluation highlights the necessity of distributing the reasoning to the mobile part of the system and that modifiable rules are able to deal with the change in lifestyle of the patients affected by chronic illnesses.
Collapse
Affiliation(s)
- Albert Brugués
- University of Applied Sciences Western Switzerland (HES-SO), Techno-Pôle 3, 3960, Sierre, Switzerland. .,Universitat Politècnica de Catalunya - BarcelonaTech (UPC), Campus Nord, Edif. C3, C. Jordi Girona, 1-3, 08034, Barcelona, Spain.
| | - Stefano Bromuri
- University of Applied Sciences Western Switzerland (HES-SO), Techno-Pôle 3, 3960, Sierre, Switzerland
| | - Michael Barry
- University of Applied Sciences Western Switzerland (HES-SO), Techno-Pôle 3, 3960, Sierre, Switzerland
| | - Óscar Jiménez Del Toro
- University of Applied Sciences Western Switzerland (HES-SO), Techno-Pôle 3, 3960, Sierre, Switzerland
| | - Maciej R Mazurkiewicz
- First Department of Family Medicine, Medical University of Lodz, ul.Narutowicza 60, Łódź, Poland
| | - Przemyslaw Kardas
- First Department of Family Medicine, Medical University of Lodz, ul.Narutowicza 60, Łódź, Poland
| | - Josep Pegueroles
- Universitat Politècnica de Catalunya - BarcelonaTech (UPC), Campus Nord, Edif. C3, C. Jordi Girona, 1-3, 08034, Barcelona, Spain
| | - Michael Schumacher
- University of Applied Sciences Western Switzerland (HES-SO), Techno-Pôle 3, 3960, Sierre, Switzerland
| |
Collapse
|
13
|
Rollins DK, Goeddel CE, Matthews SL, Mei Y, Roggendorf A, Littlejohn E, Quinn L, Cinar A. An Extended Static and Dynamic Feedback–Feedforward Control Algorithm for Insulin Delivery in the Control of Blood Glucose Level. Ind Eng Chem Res 2015. [DOI: 10.1021/ie505035r] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
| | | | | | | | | | - Elizabeth Littlejohn
- Institute
for Endocrine Discovery and Clinical Care, University of Chicago Medicine, Chicago, Illinois 60637, United States
| | - Laurie Quinn
- College
of Nursing, University of Illinois at Chicago, Chicago, Illinois 60607, United States
| | - Ali Cinar
- Department
of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, Illinois 60616, United States
| |
Collapse
|
14
|
Abstract
The primary goal of type 1 diabetes treatment is attaining near-normal glucose values. This currently remains out of reach for most people with type 1 diabetes despite intensified insulin treatment in the form of insulin analogues, educational interventions, continuous glucose monitoring, and sensor augmented insulin pump. The main remaining problem is risk of hypoglycaemia, which cannot be sufficiently reduced in all patient groups. Additionally, patients' burn-out often develops with years of tedious day-to-day diabetes management, rendering available diabetes-related technology less efficient. Over the past 40 years, several attempts have been made towards computer-programmed insulin delivery in the form of closed loop, with faster developments especially in the past decade. Automated insulin delivery has reduced human error in glycaemic control and considerably lessened the burden of routine self-management. In this chapter, data from randomized controlled trials with closed-loop insulin delivery that included type 1 diabetes population are summarized, and an evidence-based vision for possible routine utilization of closed loop is provided.
Collapse
Affiliation(s)
- Tadej Battelino
- Department of Endocrinology, Diabetes and Metabolism, UMC - University Children's Hospital, Ljubljana, Slovenia; Faculty of Medicine, University of Ljubljana, Slovenia.
| | - Jasna Šuput Omladič
- Department of Endocrinology, Diabetes and Metabolism, UMC - University Children's Hospital, Ljubljana, Slovenia
| | - Moshe Phillip
- Jesse Z. and Sara Lea Shafer Institute for Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel, Petah Tikva, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
15
|
Designing an artificial pancreas architecture: the AP@home experience. Med Biol Eng Comput 2014; 53:1271-83. [PMID: 25430423 DOI: 10.1007/s11517-014-1231-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Accepted: 11/16/2014] [Indexed: 12/17/2022]
Abstract
The latest achievements in sensor technologies for blood glucose level monitoring, pump miniaturization for insulin delivery, and the availability of portable computing devices are paving the way toward the artificial pancreas as a treatment for diabetes patients. This device encompasses a controller unit that oversees the administration of insulin micro-boluses and continuously drives the pump based on blood glucose readings acquired in real time. In order to foster the research on the artificial pancreas and prepare for its adoption as a therapy, the European Union in 2010 funded the AP@home project, following a series of efforts already ongoing in the USA. This paper, authored by members of the AP@home consortium, reports on the technical issues concerning the design and implementation of an architecture supporting the exploitation of an artificial pancreas platform. First a PC-based platform was developed by the authors to prove the effectiveness and reliability of the algorithms responsible for insulin administration. A mobile-based one was then adopted to improve the comfort for the patients. Both platforms were tested on real patients, and a description of the goals, the achievements, and the major shortcomings that emerged during those trials is also reported in the paper.
Collapse
|
16
|
Quemerais MA, Doron M, Dutrech F, Melki V, Franc S, Antonakios M, Charpentier G, Hanaire H, Benhamou PY. Preliminary evaluation of a new semi-closed-loop insulin therapy system over the prandial period in adult patients with type 1 diabetes: the WP6.0 Diabeloop study. J Diabetes Sci Technol 2014; 8:1177-84. [PMID: 25097057 PMCID: PMC4455472 DOI: 10.1177/1932296814545668] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
There is room for improvement in the algorithms used in closed-loop insulin therapy during the prandial period. This pilot study evaluated the efficacy and safety of the Diabeloop algorithm (model predictive control type) during the postprandial period. This 2-center clinical trial compared interstitial glucose levels over two 5-hour periods (with/without the algorithm) following a calibrated lunch. On the control day, the amount of insulin delivered by the pump was determined according to the patient's usual parameters. On the test day, 50% or 75% of the theoretical bolus required was delivered, while the algorithm, informed of carbohydrate intake, proposed changes to insulin delivery every 15 minutes using modeling to forecast glucose levels. The primary endpoint was percentage of time spent at near normoglycemia (70-180 mg/dl). Twelve patients with type 1 diabetes (9 men, age 35.6 ± 12.7 years, HbA1c 7.3 ± 0.8%) were included. The percentage of time spent in the target range was 84.5 ± 20.8 (test day) versus 69.2 ± 33.9% (control day, P = .11). The percentage of time spent in hypoglycemia < 70 mg/dl was 0.2 ± 0.8 (test) versus 4.4 ± 8.2% (control, P = .18). Interstitial glucose at the end of the test (5 hours) was 127.5 ± 40.1 (test) versus 146 ± 53.5 mg/dl (control, P = .25). The insulin doses did not differ, and no differences were observed between the 50% and 75% boluses. In a semi-closed-loop configuration with manual priming boluses (25% or 50% reduction), the Diabeloop v1 algorithm was as successful as the manual method in determining the prandial bolus, without any exposure to excessive hypoglycemic risk.
Collapse
Affiliation(s)
| | - Maeva Doron
- University Grenoble Alpes, Grenoble, France CEA, LETI, DTBS, Laboratoire électronique et systèmes pour la santé, Grenoble, France
| | - Florent Dutrech
- University Grenoble Alpes, Grenoble, France CEA, LETI, DTBS, Laboratoire électronique et systèmes pour la santé, Grenoble, France
| | - Vincent Melki
- Department of Diabetology, Toulouse Rangueil University Hospital, Toulouse, France
| | - Sylvia Franc
- Department of Diabetes, Sud-Francilien Hospital, Corbeil-Essonnes, France CERITD, Corbeil-Essonnes, France
| | - Michel Antonakios
- University Grenoble Alpes, Grenoble, France CEA, LETI, DTBS, Laboratoire électronique et systèmes pour la santé, Grenoble, France
| | - Guillaume Charpentier
- Department of Diabetes, Sud-Francilien Hospital, Corbeil-Essonnes, France CERITD, Corbeil-Essonnes, France
| | - Helene Hanaire
- Department of Diabetology, Toulouse Rangueil University Hospital, Toulouse, France
| | | |
Collapse
|
17
|
Peyser T, Dassau E, Breton M, Skyler JS. The artificial pancreas: current status and future prospects in the management of diabetes. Ann N Y Acad Sci 2014; 1311:102-23. [PMID: 24725149 DOI: 10.1111/nyas.12431] [Citation(s) in RCA: 107] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Recent advances in insulins, insulin pumps, continuous glucose-monitoring systems, and control algorithms have resulted in an acceleration of progress in the development of artificial pancreas devices. This review discusses progress in the development of external systems that are based on subcutaneous drug delivery and subcutaneous continuous glucose monitoring. There are two major system-level approaches to achieving closed-loop control of blood glucose in diabetic individuals. The unihormonal approach uses insulin to reduce blood glucose and relies on complex safety mitigation algorithms to reduce the risk of hypoglycemia. The bihormonal approach uses both insulin to lower blood glucose and glucagon to raise blood glucose, and also relies on complex algorithms to provide for safety of the user. There are several major strategies for the design of control algorithms and supervision control for application to the artificial pancreas: proportional-integral-derivative, model predictive control, fuzzy logic, and safety supervision designs. Advances in artificial pancreas research in the first decade of this century were based on the ongoing computer revolution and miniaturization of electronic technology. The advent of modern smartphones has created the ability to utilize smartphone technology as the engineering centerpiece of an artificial pancreas. With these advances, an artificial or bionic pancreas is within reach.
Collapse
|
18
|
Lanzola G, Scarpellini S, Di Palma F, Toffanin C, Del Favero S, Magni L, Bellazzi R. Monitoring Artificial Pancreas Trials Through Agent-based Technologies: A Case Report. J Diabetes Sci Technol 2014; 8:216-224. [PMID: 24876570 PMCID: PMC4455402 DOI: 10.1177/1932296814522120] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The increase in the availability and reliability of network connections lets envision systems supporting a continuous remote monitoring of clinical parameters useful either for overseeing chronic diseases or for following clinical trials involving outpatients. We report here the results achieved by a telemedicine infrastructure that has been linked to an artificial pancreas platform and used during a trial of the AP@home project, funded by the European Union. The telemedicine infrastructure is based on a multiagent paradigm and is able to deliver to the clinic any information concerning the patient status and the operation of the artificial pancreas. A web application has also been developed, so that the clinic staff and the researchers involved in the design of the blood glucose control algorithms are able to follow the ongoing experiments. Albeit the duration of the experiments in the trial discussed in the article was limited to only 2 days, the system proved to be successful for monitoring patients, in particular overnight when the patients are sleeping. Based on that outcome we can conclude that the infrastructure is suitable for the purpose of accomplishing an intelligent monitoring of an artificial pancreas either during longer trials or whenever that system will be used as a routine treatment.
Collapse
Affiliation(s)
- Giordano Lanzola
- Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Pavia, Italy
| | - Stefania Scarpellini
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | - Federico Di Palma
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | - Chiara Toffanin
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | - Simone Del Favero
- Department of Information Engineering, University of Padova, Padova, Italy
| | - Lalo Magni
- Department of Civil Engineering and Architecture, University of Pavia, Pavia, Italy
| | - Riccardo Bellazzi
- Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Pavia, Italy
| |
Collapse
|