1
|
McLean A, Maple-Brown L, Murphy HR. Technology advances in diabetes pregnancy: right technology, right person, right time. Diabetologia 2024; 67:2103-2113. [PMID: 38967667 DOI: 10.1007/s00125-024-06216-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 05/20/2024] [Indexed: 07/06/2024]
Abstract
This review outlines some of the extraordinary recent advances in diabetes technology, which are transforming the management of type 1 diabetes before, during and after pregnancy. It highlights recent improvements associated with use of continuous glucose monitoring (CGM) but acknowledges that neither CGM nor insulin pump therapy are adequate for achieving the pregnancy glucose targets. Furthermore, even hybrid closed-loop (HCL) systems that are clinically effective outside of pregnancy may not confer additional benefits throughout pregnancy. To date, there is only one HCL system, the CamAPS FX, with a strong evidence base for use during pregnancy, suggesting that the pregnancy benefits are HCL system specific. This is in stark contrast to HCL system use outside of pregnancy, where benefits are HCL category specific. The CamAPS FX HCL system has a rapidly adaptive algorithm and lower glucose targets with benefits across all maternal glucose categories, meaning that it is applicable for all women with type 1 diabetes, before and during pregnancy. For women of reproductive years living with type 2 diabetes, the relative merits of using non-insulin pharmacotherapies vs diabetes technology (dipeptidyl peptidase-4 inhibitors, glucagon-like peptide-1 receptor agonists and sodium-glucose cotransporter 2 inhibitors) are unknown. Despite the urgent unmet need and potential benefits, studies of pharmacotherapy and technology use are extremely limited in pregnant women with type 2 diabetes.
Collapse
Affiliation(s)
- Anna McLean
- Menzies School of Health Research, Charles Darwin University, Darwin, NT, Australia
- Endocrinology Department, Cairns Hospital, Cairns, Queensland, Australia
| | - Louise Maple-Brown
- Menzies School of Health Research, Charles Darwin University, Darwin, NT, Australia
- Endocrinology Department, Royal Darwin Hospital, Darwin, Northern Territory, Australia
| | - Helen R Murphy
- Norwich Medical School, University of East Anglia, Norwich, UK.
- Norfolk and Norwich NHS Foundation Trust, Diabetes and Antenatal Care, Norwich, UK.
| |
Collapse
|
2
|
Fresa R, Bitterman O, Cavallaro V, Di Filippi M, Dimarzo D, Mosca C, Nappi F, Rispoli M, Napoli A. An automated insulin delivery system from pregestational care to postpartum in women with type 1 diabetes. Preliminary experience with telemedicine in 6 patients. Acta Diabetol 2024; 61:1185-1194. [PMID: 38849658 DOI: 10.1007/s00592-024-02315-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Accepted: 05/29/2024] [Indexed: 06/09/2024]
Abstract
INTRODUCTION The use of most commercially available automated insulin delivery (AID) systems is off-label in pregnancy. However, an increasing number of women with type 1 diabetes (T1D) use such devices throughout pregnancy and delivery. We analysed the data of six women with T1D from a single centre (Diabetology Outpatient Clinic of District-63/Asl Salerno, Italy) who were able to start and maintain AID therapy with the MiniMed™ 780G (Medtronic, Minneapolis, MN, USA) throughout the pregestational care period, pregnancy, delivery, and postpartum. METHODS We retrospectively collected data from six patients with T1D who received training and initiation on use of the MiniMed™ 780G and attended follow-up visits throughout pregnancy (these visits were virtual because of the COVID-19 pandemic). All patients maintained their devices in the closed-loop setting throughout pregnancy and during labour and delivery. We analysed data from the pregestational phase to the first 30 days postpartum. RESULTS All patients achieved the recommended metabolic goals before conception [median time in range (TIR) of 88% for 70-180 mg/dL; median pregnancy-specific TIR 63-140 mg/dL (ps-TIR) of 66% and maintained the ps-TIR until delivery (median ps-TIR 83%). All patients had slightly better metrics during the night than during the day, with a very low time below range of < 63 mg/dL. Optimal glycaemic values were also maintained on the day of labour and delivery (median ps-TIR 92.5%) and in the first 30 days postpartum, with no severe hypoglycaemia. The only neonatal complications were jaundice in one child and an interatrial defect in another child. CONCLUSION In our well-selected and trained patients, use of the MiniMed™ 780G helped to achieve and maintain ps-metrics from the pregestational period to delivery despite the fact that the algorithm is not set to achieve the ambitious glycaemic values recommended for pregnancy.
Collapse
Affiliation(s)
- Raffaella Fresa
- Diabetology Outpatient Clinic , Asl Salerno, District 63, Salerno, Italy
| | - Olimpia Bitterman
- Diabetology Unit, San Paolo Hospital, ASL Roma 4, Civitavecchia, Rome, Italy.
| | - Vincenzo Cavallaro
- Diabetology Outpatient Clinic , Asl Salerno, District 63, Salerno, Italy
| | | | - Daniela Dimarzo
- Diabetology Outpatient Clinic , Asl Salerno, District 63, Salerno, Italy
| | - Carmela Mosca
- Diabetology Outpatient Clinic , Asl Salerno, District 63, Salerno, Italy
| | - Francesca Nappi
- Diabetology Outpatient Clinic , Asl Salerno, District 63, Salerno, Italy
| | - Marilena Rispoli
- Diabetology Outpatient Clinic , Asl Salerno, District 63, Salerno, Italy
| | - Angela Napoli
- Israelitico Hospital, Rome, Italy
- International Medical University Unicamillus, Rome, Italy
- Cdc Santa Famiglia, Rome, Italy
| |
Collapse
|
3
|
Di Molfetta S, Di Gioia L, Caruso I, Cignarelli A, Green SC, Natale P, Strippoli GFM, Sorice GP, Perrini S, Natalicchio A, Laviola L, Giorgino F. Efficacy and Safety of Different Hybrid Closed Loop Systems for Automated Insulin Delivery in People With Type 1 Diabetes: A Systematic Review and Network Meta-Analysis. Diabetes Metab Res Rev 2024; 40:e3842. [PMID: 39298688 DOI: 10.1002/dmrr.3842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/25/2024] [Accepted: 07/24/2024] [Indexed: 09/22/2024]
Abstract
AIMS To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis. METHODS We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome. RESULTS A total of 28 RCTs, all enrolling people with type 1 diabetes, were included. HCL systems significantly increased TIR compared with subcutaneous insulin therapy without continuous glucose monitoring (SIT). Minimed 780G achieved the highest TIR ahead of Control IQ (mean difference (MD) 5.1%, 95% confidence interval (95% CI) [0.68; 9.52], low certainty), Minimed 670G (MD 7.48%, 95% CI [4.27; 10.7], moderate certainty), CamAPS Fx (MD 8.94%, 95% CI [4.35; 13.54], low certainty), and DBLG1 (MD 10.69%, 95% CI [5.73; 15.65], low certainty). All HCL systems decreased time below target range, with DBLG1 (MD -3.69%, 95% CI [-5.2; -2.19], high certainty), Minimed 670G (MD -2.9%, 95% CI [-3.77; -2.04], moderate certainty) and Minimed 780G (MD -2.79%, 95% CI [-3.94; -1.64], high certainty) exhibiting the largest reductions compared to SIT. The risk of severe hypoglycaemia and diabetic ketoacidosis was similar to other types of insulin therapy. CONCLUSIONS We show a hierarchy of efficacy among the different HCL systems in people with type 1 diabetes, thus providing support to clinical decision-making. TRIAL REGISTRATION PROSPERO CRD42023453717.
Collapse
Affiliation(s)
- Sergio Di Molfetta
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Ludovico Di Gioia
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Irene Caruso
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Angelo Cignarelli
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Suetonia C Green
- Department of Medicine, University of Otago Christchurch, Christchurch, New Zealand
| | - Patrizia Natale
- Department of Precision and Regenerative Medicine and Ionian Area, University of Bari Aldo Moro, Bari, Italy
- Sydney School of Public Health, The University of Sydney, Sydney, Australia
- Nephrology, Dialysis and Transplantation Unit, Department of Medical and Surgical Sciences, University of Foggia, Foggia, Italy
| | - Giovanni F M Strippoli
- Department of Precision and Regenerative Medicine and Ionian Area, University of Bari Aldo Moro, Bari, Italy
- Sydney School of Public Health, The University of Sydney, Sydney, Australia
| | - Gian Pio Sorice
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Sebastio Perrini
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Annalisa Natalicchio
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Luigi Laviola
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| | - Francesco Giorgino
- Department of Precision and Regenerative Medicine and Ionian Area, Section of Internal Medicine, Endocrinology, Andrology and Metabolic Diseases, University of Bari Aldo Moro, Bari, Italy
| |
Collapse
|
4
|
Quirós C, Herrera Arranz MT, Amigó J, Wägner AM, Beato-Vibora PI, Azriel-Mira S, Climent E, Soldevila B, Barquiel B, Colomo N, Durán-Martínez M, Corcoy R, Codina M, Díaz-Soto G, Márquez Pardo R, Martínez-Brocca MA, Rebollo Román Á, López-Gallardo G, Cuesta M, García Fernández J, Goya M, Vega Guedes B, Mendoza Mathison LC, Perea V. Real-World Evidence of Off-Label Use of Commercially Automated Insulin Delivery Systems Compared to Multiple Daily Insulin Injections in Pregnancies Complicated by Type 1 Diabetes. Diabetes Technol Ther 2024; 26:596-606. [PMID: 38417014 DOI: 10.1089/dia.2023.0594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/01/2024]
Abstract
Aims: To compare glycemic control and maternal-fetal outcomes of women with type 1 diabetes (T1D) using hybrid closed loop (HCL) versus multiple daily insulin injections (MDI) plus continuous glucose monitoring. Methods: Multicenter prospective cohort study of pregnant women with T1D in Spain. We evaluated HbA1c and time spent within (TIR), below (TBR), and above (TAR) the pregnancy-specific glucose range of 3.5-7.8 mmol/L. Adjusted models were performed for adverse pregnancy outcomes, including baseline maternal characteristics and center. Results: One hundred twelve women were included (HCL n = 59). Women in the HCL group had a longer duration of diabetes and higher rates of prepregnancy care. There was no between-group difference in HbA1c in any trimester. However, in the second trimester, MDI users had a greater decrease in HbA1c (-6.12 ± 9.06 vs. -2.16 ± 7.42 mmol/mol, P = 0.031). No difference in TIR (3.5-7.8 mmol/L) and TAR was observed between HCL and MDI users, but with a higher total insulin dose in the second trimester [+0.13 IU/kg·day)]. HCL therapy was associated with increased maternal weight gain during pregnancy (βadjusted = 3.20 kg, 95% confidence interval [CI] 0.90-5.50). Regarding neonatal outcomes, newborns of HCL users were more likely to have higher birthweight (βadjusted = 279.0 g, 95% CI 39.5-518.5) and macrosomia (ORadjusted = 3.18, 95% CI 1.05-9.67) compared to MDI users. These associations disappeared when maternal weight gain or third trimester HbA1c was included in the models. Conclusions: In a real-world setting, HCL users gained more weight during pregnancy and had larger newborns than MDI users, while achieving similar glycemic control in terms of HbA1c and TIR.
Collapse
Affiliation(s)
- Carmen Quirós
- Endocrinology Department, Hospital Universitari Mútua de Terrassa, Terrassa, Spain
| | - María Teresa Herrera Arranz
- Endourology Department, Hospital Universitario Nuestra Señora de la Candelaria, Santa Cruz de Tenerife, Spain
| | - Judit Amigó
- Endourology Department, Hospital Universitari Vall Hebrón, Barcelona, Spain
| | - Ana M Wägner
- Endourology Department, Complejo Hospitalario Universitario Insular Materno-Infantil de Canarias, Universidad de Las Palmas de Gran Canaria, Gran Canaria, Spain
| | | | | | | | - Berta Soldevila
- Endourology Department, Hospital Universitari Germans Trias i Pujol, Badalona, Spain
| | - Beatriz Barquiel
- Endourology Department, Hospital Universitario La Paz, Madrid, Spain
| | - Natalia Colomo
- Endourology Department, Hospital Regional Universitario, Málaga, Spain
| | | | - Rosa Corcoy
- CIBER-BBN, Madrid, Spain
- Endourology Department, Hospital Universitari de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Mercedes Codina
- Endourology Department, Hospital Universitari Son Espases, Palma de Mallorca, Spain
| | - Gonzalo Díaz-Soto
- Endourology Department, Hospital Clínico Universitario de Valladolid, Valladolid, Spain
| | - Rosa Márquez Pardo
- Endourology Department, Hospital Universitario Juan Ramón Jiménez, Jerez de la Frontera, Spain
| | | | | | - Gema López-Gallardo
- Endourology Department, Hospital Universitario Virgen del Rocío, Sevilla, Spain
| | | | - Javier García Fernández
- Endourology Department, Hospital Universitario Nuestra Señora de la Candelaria, Santa Cruz de Tenerife, Spain
| | - Maria Goya
- Department of Obstetrics and Gynecology, Hospital Universitari Vall d'Hebron, Barcelona, Spain
- Hospital Universitari Vall Hebrón, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Begoña Vega Guedes
- Obstetrics and Gynecology department, Complejo Hospitalario Universitario Insular Materno-Infantil de Canarias, Gran Canaria, Spain
| | | | - Verónica Perea
- Endocrinology Department, Hospital Universitari Mútua de Terrassa, Terrassa, Spain
| |
Collapse
|
5
|
Munda A, Kovacic C, Pongrac Barlovic D. Real-world data on the Minimed 780G advanced hybrid closed-loop system use during type 1 diabetes pregnancy: One centre observational study. J Diabetes Complications 2024; 38:108795. [PMID: 38878423 DOI: 10.1016/j.jdiacomp.2024.108795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 05/22/2024] [Accepted: 06/09/2024] [Indexed: 07/28/2024]
Abstract
Aim The efficacy of hybrid closed-loop systems (HCLs) in managing glycemic control in pregnant women with type 1 diabetes remains inadequately characterized. We evaluated the use of the Medtronic Minimed 780G HCLs. METHODS The retrospective observational study analyzed the glycemic and perinatal outcomes of pregnant women using the HCLs, followed at our tertiary centre. Independent t-tests were employed to compare data among trimesters based on pre-pregnancy HbA1c. The associations between glycemic parameters and perinatal outcomes were explored using Spearman rho. RESULTS Among the 21 women (age: 33.5 ± 4.2 years, diabetes duration: 21.2 ± 7.6 years, pre-pregnancy HbA1c 7.0 ± 1.1 % (52.9 ± 11.9 mmol/mol)) time in range (pTIR, 63-140 mg/dl; 3.5-7.8 mmol/l) increased progressively throughout pregnancy (trimesters: first: 64.0 ± 9.0 %; second:71.3 ± 11.8 %; third: 75.7 ± 8.1 %). Simultaneously, mean sensor glucose decreased (trimesters: first: 130 ± 10.4 mg/dl (7.2 ± 0.6 mmol/l); second: 120.9 ± 13.4 mg/dl (6.7 ± 0.7 mmol/l); third: 117.3 ± 9.1 mg/dl (6.5 ± 0.5 mmol/l)). Although a majority of women achieved the target pTIR until the third trimester, this did not consistently prevent the delivery of a large-for-gestational-age baby. Notably, one ketoacidosis event occurred, and there were no reported instances of severe hypoglycemia. CONCLUSION Use of the Minimed 780G HCLs enabled the attainment of recommended pregnancy glycemic targets for most women with type 1 diabetes in a real-world setting.
Collapse
Affiliation(s)
- Ana Munda
- Clinical Department of Endocrinology, Diabetes and Metabolic Diseases, University Medical Centre Ljubljana, Slovenia; Faculty of Medicine, University of Ljubljana, Slovenia
| | | | - Drazenka Pongrac Barlovic
- Clinical Department of Endocrinology, Diabetes and Metabolic Diseases, University Medical Centre Ljubljana, Slovenia; Faculty of Medicine, University of Ljubljana, Slovenia.
| |
Collapse
|
6
|
Battarbee AN, Durnwald C, Yee LM, Valent AM. Continuous Glucose Monitoring for Diabetes Management During Pregnancy: Evidence, Practical Tips, and Common Pitfalls. Obstet Gynecol 2024:00006250-990000000-01115. [PMID: 39016319 DOI: 10.1097/aog.0000000000005669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 05/23/2024] [Indexed: 07/18/2024]
Abstract
Continuous glucose monitoring (CGM) has the potential to revolutionize diabetes management during pregnancy by providing detailed and real-time data to patients and clinicians, overcoming many of the limitations of self-monitoring of blood glucose. Although there are limited data on the role of CGM to improve pregnancy outcomes in patients with type 2 diabetes or gestational diabetes, CGM has been shown to reduce pregnancy complications in patients with type 1 diabetes. Despite the limited data in some populations, given its ease of use and recent U.S. Food and Drug Administration approval with expanding insurance coverage, CGM has gained widespread popularity among pregnant patients with all types of diabetes. It is critical for obstetric clinicians to understand how CGM can be successfully integrated into clinical practice. We present a practical, step-wise approach to CGM data interpretation that can be incorporated into diabetes management during pregnancy and common CGM pitfalls and solutions. Although technology will continue to advance with newer-generation CGM devices and diabetes technology such as automated insulin delivery (not covered here), these key principles form a basic foundation for understanding CGM technology and its utility for pregnant people.
Collapse
Affiliation(s)
- Ashley N Battarbee
- Center for Women's Reproductive Health and the Department of Obstetrics and Gynecology, University of Alabama at Birmingham, Birmingham, Alabama; the Department of Obstetrics and Gynecology, University of Pennsylvania, Philadelphia, Pennsylvania; the Department of Obstetrics and Gynecology, Northwestern University Feinberg School of Medicine, Chicago, Illinois; and the Department of Obstetrics and Gynecology, Oregon Health & Science University, Portland, Oregon
| | | | | | | |
Collapse
|
7
|
Szmuilowicz ED, Barbour L, Brown FM, Durnwald C, Feig DS, O’Malley G, Polsky S, Aleppo G. Continuous Glucose Monitoring Metrics for Pregnancies Complicated by Diabetes: Critical Appraisal of Current Evidence. J Diabetes Sci Technol 2024; 18:819-834. [PMID: 38606830 PMCID: PMC11307229 DOI: 10.1177/19322968241239341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/13/2024]
Abstract
Ascertaining the utility of continuous glucose monitoring (CGM) in pregnancy complicated by diabetes is a rapidly evolving area, as the prevalence of type 1 diabetes (T1D), type 2 diabetes (T2D), and gestational diabetes mellitus (GDM) escalates. The seminal randomized controlled trial (RCT) evaluating CGM use added to standard care in pregnancy in T1D demonstrated significant improvements in maternal glycemia and neonatal health outcomes. Current clinical guidance recommends targets for percentage time in range (TIR), time above range (TAR), and time below range (TBR) during pregnancy complicated by T1D that are widely used in clinical practice. However, the superiority of CGM over blood glucose monitoring (BGM) is still questioned in both T2D and GDM, and whether glucose targets should be different than in T1D is unknown. Questions requiring additional research include which CGM metrics are superior in predicting clinical outcomes, how should pregnancy-specific CGM targets be defined, whether CGM targets should differ according to gestational age, and if CGM metrics during pregnancy should be similar across all types of diabetes. Limiting the potential for CGM to improve pregnancy outcomes may be our inability to maintain TIR > 70% throughout gestation, a goal achieved in the minority of patients studied. Adverse pregnancy outcomes remain high in women with T1D and T2D in pregnancy despite CGM technology, and this review explores the potential reasons and questions yet to be investigated.
Collapse
Affiliation(s)
| | - Linda Barbour
- University of Colorado Anschutz Medical
Campus, Aurora, CO, USA
| | | | | | | | | | - Sarit Polsky
- University of Colorado Anschutz Medical
Campus, Aurora, CO, USA
| | - Grazia Aleppo
- Northwestern University Feinberg School
of Medicine, Chicago, IL, USA
| |
Collapse
|
8
|
Benhalima K, Beunen K, Van Wilder N, Ballaux D, Vanhaverbeke G, Taes Y, Aers XP, Nobels F, Marlier J, Lee D, Cuypers J, Preumont V, Siegelaar SE, Painter RC, Laenen A, Gillard P, Mathieu C. Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trial. Lancet Diabetes Endocrinol 2024; 12:390-403. [PMID: 38697182 DOI: 10.1016/s2213-8587(24)00089-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/11/2024] [Accepted: 03/11/2024] [Indexed: 05/04/2024]
Abstract
BACKGROUND Advanced hybrid closed loop (AHCL) therapy can improve glycaemic control in pregnant women with type 1 diabetes. However, data are needed on the efficacy and safety of AHCL systems as these systems, such as the MiniMed 780G, are not currently approved for use in pregnant women. We aimed to investigate whether the MiniMed 780G can improve glycaemic control with less hypoglycaemia in pregnant women with type 1 diabetes. METHODS CRISTAL was a double-arm, parallel-group, open-label, randomised controlled trial conducted in secondary and tertiary care specialist endocrinology centres at 12 hospitals (11 in Belgium and one in the Netherlands). Pregnant women aged 18-45 years with type 1 diabetes were randomly assigned (1:1) to AHCL therapy (MiniMed 780G) or standard insulin therapy (standard of care) at a median of 10·1 (IQR 8·6-11·6) weeks of gestation. Randomisation was done centrally with minimisation dependent on baseline HbA1c, insulin administration method, and centre. Participants and study teams were not masked to group allocation. The primary outcome was proportion of time spent in the pregnancy-specific target glucose range (3·5-7·8 mmol/L), measured by continuous glucose monitoring (CGM) at 14-17 weeks, 20-23 weeks, 26-29 weeks, and 33-36 weeks. Key secondary outcomes were overnight time in target range, and time below glucose range (<3·5 mmol/L) overall and overnight. Analyses were conducted on an intention-to-treat basis. This trial is registered with ClinicalTrials.gov (NCT04520971). FINDINGS Between Jan 15, 2021 and Sept 30, 2022, 101 participants were screened, and 95 were randomly assigned to AHCL therapy (n=46) or standard insulin therapy (n=49). 43 patients assigned to AHCL therapy and 46 assigned to standard insulin therapy completed the study. At baseline, 91 (95·8%) participants used insulin pumps, and the mean HbA1c was 6·5% (SD 0·6). The mean proportion of time spent in the target range (averaged over four time periods) was 66·5% (SD 10·0) in the AHCL therapy group compared with 63·2% (12·4) in the standard insulin therapy group (adjusted mean difference 1·88 percentage points [95% CI -0·82 to 4·58], p=0·17). Overnight time in the target range was higher (adjusted mean difference 6·58 percentage points [95% CI 2·31 to 10·85], p=0·0026), and time below range overall (adjusted mean difference -1·34 percentage points [95% CI, -2·19 to -0·49], p=0·0020) and overnight (adjusted mean difference -1·86 percentage points [95% CI -2·90 to -0·81], p=0·0005) were lower with AHCL therapy than with standard insulin therapy. Participants assigned to AHCL therapy reported higher treatment satisfaction. No unanticipated safety events occurred with AHCL therapy. INTERPRETATION In pregnant women starting with tighter glycaemic control, AHCL therapy did not improve overall time in target range but improved overnight time in target range, reduced time below range, and improved treatment satisfaction. These data suggest that the MiniMed 780G can be safely used in pregnancy and provides some additional benefits compared with standard insulin therapy; however, it will be important to refine the algorithm to better align with pregnancy requirements. FUNDING Diabetes Liga Research Fund and Medtronic.
Collapse
Affiliation(s)
- Katrien Benhalima
- Clinical and Experimental Endocrinology, Department of Chronic Diseases and Metabolism, KU Leuven, Leuven, Belgium; Department of Endocrinology, UZ Leuven, Leuven, Belgium.
| | - Kaat Beunen
- Clinical and Experimental Endocrinology, Department of Chronic Diseases and Metabolism, KU Leuven, Leuven, Belgium
| | - Nancy Van Wilder
- Department of Endocrinology, University Hospital Brussels, Jette, Belgium
| | - Dominique Ballaux
- Department of Endocrinology, Vitaz Campus Sint-Niklaas Moerland, Sint-Niklaas, Belgium
| | - Gerd Vanhaverbeke
- Department of Endocrinology, General Hospital Groeninge Kortrijk, Kortrijk, Belgium
| | - Youri Taes
- Department of Endocrinology, General Hospital Sint-Jan Brugge, Brugge, Belgium
| | - Xavier-Philippe Aers
- Department of Endocrinology, General Hospital Delta Campus Rumbeke, Roeselare, Belgium
| | - Frank Nobels
- Department of Endocrinology, OLV Hospital Aalst, Aalst, Belgium
| | - Joke Marlier
- Department of Endocrinology, Ghent University Hospital, Gent, Belgium
| | - Dahae Lee
- Department of Endocrinology, Imelda Hospital Bonheiden, Bonheiden, Belgium
| | - Joke Cuypers
- Department of Endocrinology, General Hospital Turnhout Campus Sint-Jozef, Turnhout, Belgium
| | - Vanessa Preumont
- Department of Endocrinology, University Hospital Saint-Luc, Brussel, Belgium
| | - Sarah E Siegelaar
- Department of Endocrinologyand Metabolism, Amsterdam UMC location University of Amsterdam, Amsterdam, Netherlands; Amsterdam Gastroenterology Endocrinology and Metabolism, Amsterdam University Medical Centres, Amsterdam, Netherlands
| | - Rebecca C Painter
- Department of Obstetrics & Gynecology, Amsterdam University Medical Centres, Amsterdam, Netherlands; Amsterdam Reproduction and Development, Amsterdam University Medical Centres, Amsterdam, Netherlands
| | - Annouschka Laenen
- Center of Biostatics and Statistical bioinformatics, KU Leuven, Leuven, Belgium
| | - Pieter Gillard
- Clinical and Experimental Endocrinology, Department of Chronic Diseases and Metabolism, KU Leuven, Leuven, Belgium; Department of Endocrinology, UZ Leuven, Leuven, Belgium
| | - Chantal Mathieu
- Clinical and Experimental Endocrinology, Department of Chronic Diseases and Metabolism, KU Leuven, Leuven, Belgium; Department of Endocrinology, UZ Leuven, Leuven, Belgium
| |
Collapse
|
9
|
Murphy HR. A Diabetes Pregnancy Technology Roadmap: The 2023 Norbert Freinkel Award Lecture. Diabetes Care 2024; 47:324-330. [PMID: 38394634 DOI: 10.2337/dci23-0067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Abstract
Norbert Freinkel emphasized the need for "more aggressive therapy with exogenous insulin" during type 1 diabetes (T1D) pregnancy. Recent advances in diabetes technology, continuous glucose monitoring (CGM), and hybrid closed-loop (HCL) insulin delivery systems allow us to revisit Freinkel's observations from a contemporary perspective. The Continuous Glucose Monitoring in Women With Type 1 Diabetes in Pregnancy Trial (CONCEPTT) led to international recommendations that CGM be offered to all pregnant women with T1D to help them meet their pregnancy glucose targets and improve neonatal outcomes. However, despite CGM use, only 35% of trial participants reached the pregnancy glucose targets by 35 weeks' gestation, which is too late for optimal obstetric and neonatal outcomes. The constant vigilance to CGM data and insulin dose adjustment, with perpetual worry about the impact of hyperglycemia on the developing fetal structures, leave many pregnant women feeling overwhelmed. HCL systems that can adapt to marked gestational changes in insulin sensitivity and pharmacokinetics may help to bridge the gap between the nonpregnant time in range glycemic targets (70-180 mg/dL) and the substantially more stringent pregnancy-specific targets (TIRp) (63-140 mg/dL) required for optimal obstetric and neonatal outcomes. Use of HCL (CamAPS FX system) was associated with a 10.5% higher TIRp, 10.2% less hyperglycemia, and 12.3% higher overnight TIRp. Clinical benefits were accompanied by 3.7 kg (8 lb) less gestational weight gain and consistently achieved across a representative patient population of insulin pump or injection users, across trial sites, and across maternal HbA1c categories. Working collaboratively, women, HCL technology, and health care teams achieved improved glycemia with less worry, less work, and more positive pregnancy experiences.
Collapse
Affiliation(s)
- Helen R Murphy
- Norwich Medical School, University of East Anglia, and Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, U.K
| |
Collapse
|
10
|
Benhalima K, Jendle J, Beunen K, Ringholm L. Automated Insulin Delivery for Pregnant Women With Type 1 Diabetes: Where do we stand? J Diabetes Sci Technol 2024:19322968231223934. [PMID: 38197363 DOI: 10.1177/19322968231223934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
Automated insulin delivery (AID) systems mimic an artificial pancreas via a predictive algorithm integrated with continuous glucose monitoring (CGM) and an insulin pump, thereby providing AID. Outside of pregnancy, AID has led to a paradigm shift in the management of people with type 1 diabetes (T1D), leading to improvements in glycemic control with lower risk for hypoglycemia and improved quality of life. As the use of AID in clinical practice is increasing, the number of women of reproductive age becoming pregnant while using AID is also expected to increase. The requirement for lower glucose targets than outside of pregnancy and for frequent adjustments of insulin doses during pregnancy may impact the effectiveness and safety of AID when using algorithms for non-pregnant populations with T1D. Currently, the CamAPS® FX is the only AID approved for use in pregnancy. A recent randomized controlled trial (RCT) with CamAPS® FX demonstrated a 10% increase in time in range in a pregnant population with T1D and a baseline glycated hemoglobin (HbA1c) ≥ 48 mmol/mol (6.5%). Off-label use of AID not approved for pregnancy are currently also being evaluated in ongoing RCTs. More evidence is needed on the impact of AID on maternal and neonatal outcomes. We review the current evidence on the use of AID in pregnancy and provide an overview of the completed and ongoing RCTs evaluating AID in pregnancy. In addition, we discuss the advantages and challenges of the use of current AID in pregnancy and future directions for research.
Collapse
Affiliation(s)
- Katrien Benhalima
- Department of Endocrinology, University Hospital Gasthuisberg, KU Leuven, Leuven, Belgium
| | - Johan Jendle
- Diabetes Endocrinology and Metabolism Research Centre, School of Medicine, Örebro University, Örebro, Sweden
| | - Kaat Beunen
- Department of Endocrinology, University Hospital Gasthuisberg, KU Leuven, Leuven, Belgium
| | - Lene Ringholm
- Center for Pregnant Women with Diabetes, Department of Endocrinology and Metabolism, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
11
|
ElSayed NA, Aleppo G, Bannuru RR, Bruemmer D, Collins BS, Ekhlaspour L, Hilliard ME, Johnson EL, Khunti K, Lingvay I, Matfin G, McCoy RG, Perry ML, Pilla SJ, Polsky S, Prahalad P, Pratley RE, Segal AR, Seley JJ, Stanton RC, Gabbay RA. 7. Diabetes Technology: Standards of Care in Diabetes-2024. Diabetes Care 2024; 47:S126-S144. [PMID: 38078575 PMCID: PMC10725813 DOI: 10.2337/dc24-s007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
The American Diabetes Association (ADA) "Standards of Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, an interprofessional expert committee, are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations and a full list of Professional Practice Committee members, please refer to Introduction and Methodology. Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
12
|
Nandam N, Thung S, Venkatesh KK, Gabbe S, Ma J, Peng J, Dungan K, Buschur EO. Tandem T:Slim X2 Insulin Pump Use in Clinical Practice Among Pregnant Individuals With Type 1 Diabetes: A Retrospective Observational Cohort Study. Cureus 2024; 16:e52369. [PMID: 38361690 PMCID: PMC10868538 DOI: 10.7759/cureus.52369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/15/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND Insulin pump use is increasing in frequency among pregnant individuals with type 1 diabetes (T1D). Automated insulin delivery (AID) technologies have not been studied extensively in pregnancy. METHOD We present a retrospective case series of eight individuals with T1D who used the Tandem t:slim X2 insulin pump (Tandem Diabetes Care, Inc., CA, USA) during pregnancy. Weekly continuous glucose monitor and insulin pump data were analyzed from electronic medical records and data-sharing portals. Safety, glycemic control, and pregnancy outcomes were examined with both the control IQ (CIQ) and basal IQ (BIQ) algorithms. RESULTS Six CIQ and two BIQ users were studied. The mean glycated hemoglobin (A1C) during pregnancy was 6.1%, and the average time in pregnancy-recommended glycemic range (TIR; 63-140mg/dL) was 67.9%. There were no instances of diabetic ketoacidosis or severe hypoglycemia. CIQ users had a higher mean sensor glucose (127.6 mg/dL) compared to BIQ participants (118.4 mg/dL). However, the average time below range (<63 mg/dL) was 6.1% in BIQ participants compared to 1.5% in CIQ participants. CIQ participants used several strategies to achieve glycemic targets, including daytime use of sleep activity. An increased basal-to-bolus insulin ratio was negatively correlated with TIR (r=-0.415). CONCLUSIONS Tandem t:slim X2 insulin pumps were safely used during pregnancy in eight individuals with T1D, with variable success in achieving recommended glycemic targets. Further research is needed to understand differences in CIQ and BIQ use in pregnancy. AID device manufacturers must additionally develop further methods to target lower glucose for pregnant users.
Collapse
Affiliation(s)
- Neeharika Nandam
- Department of Endocrinology, Diabetes, and Metabolism, Cleveland Clinic, Cleveland, USA
| | - Stephen Thung
- Division of Maternal Fetal-Medicine, Department of Obstetrics, Gynecology, and Reproductive Sciences, Yale School of Medicine, Bridgeport, USA
| | - Kartik K Venkatesh
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Ohio State University Wexner Medical Center, Columbus, USA
| | - Steven Gabbe
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Ohio State University Wexner Medical Center, Columbus, USA
| | - Jianing Ma
- Center for Biostatistics, Ohio State University Wexner Medical Center, Columbus, USA
| | - Jing Peng
- Center for Biostatistics, Ohio State University Wexner Medical Center, Columbus, USA
| | - Kathleen Dungan
- Division of Endocrinology, Diabetes, and Metabolism, Ohio State University Wexner Medical Center, Columbus, USA
| | - Elizabeth O Buschur
- Division of Endocrinology, Diabetes, and Metabolism, Ohio State University Wexner Medical Center, Columbus, USA
| |
Collapse
|
13
|
ElSayed NA, Aleppo G, Bannuru RR, Bruemmer D, Collins BS, Ekhlaspour L, Hilliard ME, Johnson EL, Khunti K, Lingvay I, Matfin G, McCoy RG, Perry ML, Pilla SJ, Polsky S, Prahalad P, Pratley RE, Segal AR, Seley JJ, Stanton RC, Gabbay RA. 15. Management of Diabetes in Pregnancy: Standards of Care in Diabetes-2024. Diabetes Care 2024; 47:S282-S294. [PMID: 38078583 PMCID: PMC10725801 DOI: 10.2337/dc24-s015] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
The American Diabetes Association (ADA) "Standards of Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, an interprofessional expert committee, are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations and a full list of Professional Practice Committee members, please refer to Introduction and Methodology. Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
14
|
Garg SK, Polsky S. Technology Use and Glycemic Outcomes during Pregnancy with Type 1 Diabetes. N Engl J Med 2023; 389:1617-1619. [PMID: 37796238 DOI: 10.1056/nejme2310798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Affiliation(s)
- Satish K Garg
- From the Barbara Davis Center for Diabetes, University of Colorado, Denver
| | - Sarit Polsky
- From the Barbara Davis Center for Diabetes, University of Colorado, Denver
| |
Collapse
|
15
|
Diaz-Garelli F, Shah A, Mikhno A, Agrawal P, Kinnischtzke A, Vigersky RA. Using Continuous Glucose Monitoring Values for Bolus Size Calculation in Smart Multiple Daily Injection Systems: No Negative Impact on Post-bolus Glycemic Outcomes Found in Real-World Data. J Diabetes Sci Technol 2023:19322968231202803. [PMID: 37743727 DOI: 10.1177/19322968231202803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/26/2023]
Abstract
BACKGROUND Recent evidence shows that it may be safe to estimate bolus sizes based on continuous glucose monitoring (CGM) rather than blood glucose (BG) values using glycemic trend-adjusted bolus calculators. Users may already be doing this in the real world, though it is unclear whether this is safe or effective for calculators not employing trend adjustment. METHODS We assessed real-world data from a smart multiple daily injections (MDIs) device users with a CGM system, hypothesizing that four-hour post-bolus outcomes using CGM values are not inferior to those using BG values. Our data set included 184 users and spanned 18 months with 79 000 bolus observations. We tested differences using logistic regression predicting CGM or BG value usage based on outcomes and confirmed initial results using a mixed model regression accounting for within-subject correlations. RESULTS Comparing four-hour outcomes for bolus events using CGM and BG values revealed no differences using our initial approach (P > .183). This finding was confirmed by our mixed model regression approach in all cases (P > .199), except for times below range outcomes. Higher times below range were predictive of lower odds of CGM-based bolus calculations (OR = 0.987, P < .0001 and OR = 0.987, P = .0276, for time below 70 and 54 mg/dL, respectively). CONCLUSIONS We found no differences in four-hour post-bolus glycemic outcomes when using CGM or BG except for time below range, which showed evidence of being lower for CGM. Though preliminary, our results confirm prior findings showing non-inferiority of using CGM values for bolus calculation compared with BG usage in the real world.
Collapse
|
16
|
Albert L, Romero A, Capel I, Cano A, Subías D, Casamitjana L, Mazarico I, Rigla M. Off-label use of an automated insulin delivery system in pregnant women with type 1 diabetes. Diabetes Res Clin Pract 2023; 202:110800. [PMID: 37364659 DOI: 10.1016/j.diabres.2023.110800] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 06/18/2023] [Accepted: 06/21/2023] [Indexed: 06/28/2023]
Abstract
Using commercially available automated insulin delivery (AID) systems for treating type 1 diabetes during pregnancy remains controversial. This retrospective study assessed six pregnant women with type 1 diabetes who underwent AID therapy. Our observations revealed that AID treatment, in most cases, did not achieve the desired glycemic targets for pregnancy.
Collapse
Affiliation(s)
- Lara Albert
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain.
| | - Ana Romero
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain
| | - Ismael Capel
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain
| | - Albert Cano
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain
| | - David Subías
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain
| | - Laia Casamitjana
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain
| | - Isabel Mazarico
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain
| | - Mercedes Rigla
- Endocrinology and Nutrition Department, Parc Taulí Hospital Universitari, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell (Barcelona), Spain
| |
Collapse
|