Reconciling Oxygen and Aerosol Delivery with a Hood on In Vitro Infant and Paediatric Models. Pharmaceutics 2021; 14:pharmaceutics14010091. [PMID: 35056987 PMCID: PMC8779027 DOI: 10.3390/pharmaceutics14010091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 12/21/2021] [Accepted: 12/28/2021] [Indexed: 11/17/2022] Open
Abstract
This study aimed to evaluate optimal aerosol and oxygen delivery with a hood on an infant model and a paediatric model. A facemask and a hood with three inlets, with or without a front cover, were used. A small-volume nebuliser with a unit-dose of salbutamol was used for drug delivery and an air entrainment nebuliser was used to deliver oxygen at 35%. Infant and paediatric breathing patterns were mimicked; a bacterial filter was connected to the end of a manikin trachea for aerosol drug collection, and an oxygen analyser was used to measure the oxygen concentration. For the infant model, inhaled drug dose was significantly higher when the nebuliser was placed in the back of the hood and with a front cover. This was verified by complementary computational simulations in a comparable infant-hood model. For the paediatric model, the inhaled dose was greater with a facemask than with a hood. Oxygen delivery with a facemask and a hood with a front cover achieved a set concentration in both models, yet a hood without a front cover delivered oxygen at far lower concentrations than the set concentration.
Collapse
|
2
|
Ari A. A path to successful patient outcomes through aerosol drug delivery to children: a narrative review. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:593. [PMID: 33987291 PMCID: PMC8105845 DOI: 10.21037/atm-20-1682] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 07/03/2020] [Indexed: 11/06/2022]
Abstract
Although using aerosolized medications is a mainstay of treatment in children with asthma and other respiratory diseases, there are many issues in terms of device and interface selection, delivery technique and dosing, as well as patient and parental education that have not changed for half a century. Also, due to many aerosol devices and interfaces available on the market and the broad range of patient characteristics and requirements, providing effective aerosol therapy to children becomes a challenge. While aerosol delivery devices are equally effective, if they are age-appropriate and used correctly, the majority of aerosol devices require multiple steps to be used efficiently. Unfortunately, many children with pulmonary diseases have problems with the correct delivery technique and do not gain therapeutic benefits from therapy that result in poor disease management and increased healthcare costs. Therefore, the purpose of this paper is to review the current knowledge on aerosol delivery devices used in children and guide clinicians on the optimum device- and interface-selection, delivery technique, and dosing in this patient population. Strategies on how to deliver aerosolized medications in crying and distressed children and how to educate parents on aerosol therapy and promote patient adherence to prescribed medications are also provided. Future directions of aerosol therapy in children should focus on these issues and implement policies and clinical practices that highlight the potential solutions to these problems.
Collapse
Affiliation(s)
- Arzu Ari
- Department of Respiratory Care, Texas State University, Round Rock, TX, USA
| |
Collapse
|
3
|
Longest W, Spence B, Hindle M. Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs. J Aerosol Med Pulm Drug Deliv 2019; 32:317-339. [PMID: 31287369 DOI: 10.1089/jamp.2018.1508] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Nebulizers have a number of advantages for the delivery of inhaled pharmaceutical aerosols, including the use of aqueous formulations and the ability to deliver process-sensitive proteins, peptides, and biological medications. A frequent disadvantage of nebulized aerosols is poor lung delivery efficiency, which wastes valuable medications, increases delivery times, and may increase side effects of the medication. A focus of previous development efforts and previous nebulizer reviews, has been an improvement of the underlying nebulization technology controlling the breakup of a liquid into droplets. However, for a given nebulization technology, a wide range of secondary devices and strategies can be implemented to significantly improve lung delivery efficiency of the aerosol. This review focuses on secondary devices and technologies that can be implemented to improve the lung delivery efficiency of nebulized aerosols and potentially target the region of drug delivery within the lungs. These secondary devices may (1) modify the aerosol size distribution, (2) synchronize aerosol delivery with inhalation, (3) reduce system depositional losses at connection points, (4) improve the patient interface, or (5) guide patient inhalation. The development of these devices and technologies is also discussed, which often includes the use of computational fluid dynamic simulations, three-dimensional printing and rapid prototype device and airway model construction, realistic in vitro experiments, and in vivo analysis. Of the devices reviewed, the implementation of streamlined components may be the most direct and lowest cost approach to enhance aerosol delivery efficiency within nonambulatory nebulizer systems. For applications involving high-dose medications or precise dose administration, the inclusion of active devices to control aerosol size, guide inhalation, and synchronize delivery with inhalation hold considerable promise.
Collapse
Affiliation(s)
- Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia.,Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Benjamin Spence
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
4
|
Longest PW, Bass K, Dutta R, Rani V, Thomas ML, El-Achwah A, Hindle M. Use of computational fluid dynamics deposition modeling in respiratory drug delivery. Expert Opin Drug Deliv 2019; 16:7-26. [PMID: 30463458 PMCID: PMC6529297 DOI: 10.1080/17425247.2019.1551875] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 11/20/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Respiratory drug delivery is a surprisingly complex process with a number of physical and biological challenges. Computational fluid dynamics (CFD) is a scientific simulation technique that is capable of providing spatially and temporally resolved predictions of many aspects related to respiratory drug delivery from initial aerosol formation through respiratory cellular drug absorption. AREAS COVERED This review article focuses on CFD-based deposition modeling applied to pharmaceutical aerosols. Areas covered include the development of new complete-airway CFD deposition models and the application of these models to develop a next-generation of respiratory drug delivery strategies. EXPERT OPINION Complete-airway deposition modeling is a valuable research tool that can improve our understanding of pharmaceutical aerosol delivery and is already supporting medical hypotheses, such as the expected under-treatment of the small airways in asthma. These complete-airway models are also being used to advance next-generation aerosol delivery strategies, like controlled condensational growth. We envision future applications of CFD deposition modeling to reduce the need for human subject testing in developing new devices and formulations, to help establish bioequivalence for the accelerated approval of generic inhalers, and to provide valuable new insights related to drug dissolution and clearance leading to microdosimetry maps of drug absorption.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| | - Karl Bass
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Rabijit Dutta
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Vijaya Rani
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Morgan L. Thomas
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Ahmad El-Achwah
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA, USA
| |
Collapse
|
5
|
Ari A. Drug delivery interfaces: A way to optimize inhalation therapy in spontaneously breathing children. World J Clin Pediatr 2016; 5:281-287. [PMID: 27610343 PMCID: PMC4978620 DOI: 10.5409/wjcp.v5.i3.281] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2016] [Revised: 05/03/2016] [Accepted: 07/13/2016] [Indexed: 02/06/2023] Open
Abstract
There are several different types of drug delivery interfaces available on the market. Using the right interface for aerosol drug delivery to children is essential for effective inhalation therapy. However, clinicians usually focus on selecting the right drug-device combination and often overlook the importance of interface selection that lead to suboptimal drug delivery and therapeutic response in neonates and pediatrics. Therefore, it is necessary to critically assess each interface and understand its advantage and disadvantages in aerosol drug delivery to this patient population. The purpose of this paper is to provide a critical assessment of drug delivery interfaces used for the treatment of children with pulmonary diseases by emphasizing advantages and problems associated with their use during inhalation therapy.
Collapse
|
6
|
Carrigy NB, Ruzycki CA, Golshahi L, Finlay WH. Pediatric in vitro and in silico models of deposition via oral and nasal inhalation. J Aerosol Med Pulm Drug Deliv 2015; 27:149-69. [PMID: 24870701 DOI: 10.1089/jamp.2013.1075] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Respiratory tract deposition models provide a useful method for optimizing the design and administration of inhaled pharmaceutical aerosols, and can be useful for estimating exposure risks to inhaled particulate matter. As aerosol must first pass through the extrathoracic region prior to reaching the lungs, deposition in this region plays an important role in both cases. Compared to adults, much less extrathoracic deposition data are available with pediatric subjects. Recently, progress in magnetic resonance imaging and computed tomography scans to develop pediatric extrathoracic airway replicas has facilitated addressing this issue. Indeed, the use of realistic replicas for benchtop inhaler testing is now relatively common during the development and in vitro evaluation of pediatric respiratory drug delivery devices. Recently, in vitro empirical modeling studies using a moderate number of these realistic replicas have related airway geometry, particle size, fluid properties, and flow rate to extrathoracic deposition. Idealized geometries provide a standardized platform for inhaler testing and exposure risk assessment and have been designed to mimic average in vitro deposition in infants and children by replicating representative average geometrical dimensions. In silico mathematical models have used morphometric data and aerosol physics to illustrate the relative importance of different deposition mechanisms on respiratory tract deposition. Computational fluid dynamics simulations allow for the quantification of local deposition patterns and an in-depth examination of aerosol behavior in the respiratory tract. Recent studies have used both in vitro and in silico deposition measurements in realistic pediatric airway geometries to some success. This article reviews the current understanding of pediatric in vitro and in silico deposition modeling via oral and nasal inhalation.
Collapse
Affiliation(s)
- Nicholas B Carrigy
- 1 Aerosol Research Laboratory of Alberta, Department of Mechanical Engineering, University of Alberta , Edmonton, Alberta, Canada T6G 2G8
| | | | | | | |
Collapse
|
7
|
Kim J, Xi J, Si X, Berlinski A, Su WC. Hood nebulization: effects of head direction and breathing mode on particle inhalability and deposition in a 7-month-old infant model. J Aerosol Med Pulm Drug Deliv 2013; 27:209-18. [PMID: 23808762 DOI: 10.1089/jamp.2013.1051] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Aerosol drug delivery to infants is a strong function of their behavior. Infants can be active during medication administration, changing head position or breathing mode. The objective was to evaluate the influence of the head direction and breathing mode on the hood drug delivery in a 7-month-old girl airway model by using an approach that couples imaging with computational fluid dynamics (CFD). Three head directions, i.e., face up, face side, and sitting (face front), and two breathing modes, i.e., oronasal and nasal breathing, were studied. METHODS The face-airway model was developed from computed tomography scans of a 7-month-old girl. Respiratory airflows and particle transport were simulated with the low Reynolds number κ-ω turbulence model and Lagrangian tracking approach. Three pharmaceutical aerosol sizes (1, 2.5, and 5 μm) via hood nebulization were considered under quiet breathing conditions (5 L/min). RESULTS Both head direction and breathing mode can noticeably affect aerosol inhalability and lung delivery efficiency. A maximum of 20% difference in inhalability is observed among the three head positions. Facial-ocular depositions are predominantly influenced by head position, but not breathing mode. The facial-ocular deposition rate with the face-up position is about threefold that with the sitting position for 5-μm particles. Nasal breathing gives about 17.8% lower lung deposition and about 65% higher facial-ocular deposition than the oronasal breathing. CONCLUSION The face-side position has less facial-ocular deposition than the face-up position, while still achieving similar lung delivery efficiency. Because aerosols deposited around the eyes may cause irritation to the eyes, the face-side position appears to be a better option than the face-up position for comfort and safety reasons.
Collapse
Affiliation(s)
- JongWon Kim
- 1 Department of Mechanical and Biomedical Engineering, Central Michigan University , Mount Pleasant, MI 48858
| | | | | | | | | |
Collapse
|
8
|
Amirav I, Newhouse MT. Aerosol therapy in infants and toddlers: past, present and future. Expert Rev Respir Med 2010; 2:597-605. [PMID: 20477295 DOI: 10.1586/17476348.2.5.597] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Infants and toddlers are a unique subpopulation with regard to aerosol therapy. There are various anatomical, physiological and emotional factors peculiar to this age group that present significant difficulties and challenges for aerosol delivery. Most studies on the factors determining lung deposition of therapeutic aerosols are based on data from adults or older children, which cannot simply be extrapolated directly to infants. The present review describes why infants/toddlers are very different with respect to two major issues - namely their anatomy/physiology and their behavior. We suggest possible solutions and future research directions aimed at improving clinical outcomes of aerosol therapy in this age group.
Collapse
Affiliation(s)
- Israel Amirav
- Pediatric Department, Ziv Medical Center, Safed, Faculty of Medicine, Technion, Haifa, Israel.
| | | |
Collapse
|
9
|
Zachow S, Muigg P, Hildebrandt T, Doleisch H, Hege HC. Visual exploration of nasal airflow. IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS 2009; 15:1407-1414. [PMID: 19834215 DOI: 10.1109/tvcg.2009.198] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Rhinologists are often faced with the challenge of assessing nasal breathing from a functional point of view to derive effective therapeutic interventions. While the complex nasal anatomy can be revealed by visual inspection and medical imaging, only vague information is available regarding the nasal airflow itself: Rhinomanometry delivers rather unspecific integral information on the pressure gradient as well as on total flow and nasal flow resistance. In this article we demonstrate how the understanding of physiological nasal breathing can be improved by simulating and visually analyzing nasal airflow, based on an anatomically correct model of the upper human respiratory tract. In particular we demonstrate how various Information Visualization (InfoVis) techniques, such as a highly scalable implementation of parallel coordinates, time series visualizations, as well as unstructured grid multi-volume rendering, all integrated within a multiple linked views framework, can be utilized to gain a deeper understanding of nasal breathing. Evaluation is accomplished by visual exploration of spatio-temporal airflow characteristics that include not only information on flow features but also on accompanying quantities such as temperature and humidity. To our knowledge, this is the first in-depth visual exploration of the physiological function of the nose over several simulated breathing cycles under consideration of a complete model of the nasal airways, realistic boundary conditions, and all physically relevant time-varying quantities.
Collapse
|
10
|
Amirav I, Shakked T, Broday DM, Katoshevski D. Numerical investigation of aerosol deposition at the eyes when using a hood inhaler for infants--a 3D simulation. J Aerosol Med Pulm Drug Deliv 2008; 21:207-14. [PMID: 18518796 DOI: 10.1089/jamp.2007.0619] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
A numerical investigation of a hood inhaler is presented, aiming at the assessment of the amount of aerosol that reaches the eyes of the patient when administering medications with such a device. Using a hood for aerosol therapy for infants was already found to be effective and friendly to handle over the commonly used face mask. Using a hood device may adversely deliver unwanted medications to the eyes of the infant. The current study addresses the extent of aerosol deposition at the infant's eye zone. We describe the development and utilization of a numerical simulation for studying the transport and fate of the aerosol particles within a 3D realistic representation of the hood and the infant's head, with a focus on the eye zone. The governing equations were solved using the commercial software, FLUENT 6.1, which is based on the finite volume method. The computational domain was created using the GAMBIT package. The computational geometry was built separately for each configuration of the hood and the infant. It is shown that under optimal working conditions (i.e., when the infant's head is aligned to the funnel) the percentage of aerosol reaching the eye zone is 0.48%. However, when the funnel is tilted toward the eyes the amount of aerosol reaching the eyes zone is predicted to be 4.7%. In general, the results obtained in this study are in good agreement with available in vitro data. It can be concluded that using the hood for aerosol therapy results in minimal deposition at the infant's eye area.
Collapse
Affiliation(s)
- Israel Amirav
- Pediatric Department, Ziv Medical Center, Safed and Faculty of Medicine, Technion, Haifa, Israel
| | | | | | | |
Collapse
|