1
|
Bista P, Ratschow AD, Butt HJ, Weber SAL. High Voltages in Sliding Water Drops. J Phys Chem Lett 2023; 14:11110-11116. [PMID: 38052008 PMCID: PMC10726385 DOI: 10.1021/acs.jpclett.3c02864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 11/22/2023] [Accepted: 11/28/2023] [Indexed: 12/07/2023]
Abstract
Water drops on insulating hydrophobic substrates can generate electric potentials of kilovolts upon sliding for a few centimeters. We show that the drop saturation voltage corresponds to an amplified value of the solid-liquid surface potential at the substrate. The amplification is given by the substrate geometry, the drop and substrate dielectric properties, and the Debye length within the liquid. Next to enabling an easy and low-cost way to measure surface- and zeta- potentials, the high drop voltages have implications for energy harvesting, droplet microfluidics, and electrostatic discharge protection.
Collapse
Affiliation(s)
- Pravash Bista
- Max
Planck Institute for Polymer Research, Ackermannweg 10, Mainz 55128, Germany
| | - Aaron D. Ratschow
- Institute
for Nano- and Microfluidics, TU Darmstadt, Peter-Grünberg-Strasse 10, Darmstadt 64289, Germany
| | - Hans-Jürgen Butt
- Max
Planck Institute for Polymer Research, Ackermannweg 10, Mainz 55128, Germany
| | - Stefan A. L. Weber
- Max
Planck Institute for Polymer Research, Ackermannweg 10, Mainz 55128, Germany
- Department
of Physics, Johannes Gutenberg University, Staudingerweg 10, Mainz 55128, Germany
| |
Collapse
|
2
|
Zarogoulidis P, Petridis D, Huang H, Bai C, Oikonomou P, Nikolaou C, Matthaios D, Perdikouri EI, Papadopoulos V, Petanidis S, Kosmidis C, Charalampidis C, Hohenforst-Schmidt W, Kougkas N, Sardeli C. Inhaled nintentanib, pirfenidone and macitentan for pulmonary fibrosis: a laboratory experiment. Ther Deliv 2023; 14:491-498. [PMID: 37584210 DOI: 10.4155/tde-2023-0045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/17/2023] Open
Abstract
Aim: Idiopathic pulmonary fibrosis is a rare disease with few efficient drugs in the market. The consequences of this disease are mainly respiratory failure and pulmonary hypertension. Materials & methods: In our experiment we used the drugs pirfenidone, nintetanib and macitentan. We performed nebulization experiments with three jet nebulizers and three ultrasound nebulizers with different combinations of residual cup designs, and residual cup loadings in order to identify which combination produces droplets of less than 5 μm in mass median aerodynamic diameter. Results: Pirfenidone versus nintetanib had smaller droplet size formation at both inhaled technologies (1.37 < 2.23 and 1.92 < 3.11, jet and ultrasound respectively). Discussion: Pirfenidone and nintetanib can be administered as aerosol in any type of nebulization system.
Collapse
Affiliation(s)
- Paul Zarogoulidis
- Pulmonary Department, General Clinic Euromedica, Thessaloniki, Greece
- 3rd University Surgery Department, "AHEPA" University Hospital, Thessaloniki, Greece
| | - Dimitris Petridis
- Department of Food Technology, School of Food Technology & Nutrition, Alexander Technological Educational Institute, Thessaloniki, Greece
| | - Haidong Huang
- Department of Respiratory & Critical Care Medicine, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, China
| | - Chong Bai
- Department of Respiratory & Critical Care Medicine, Changhai Hospital, Navy Military Medical University, Shanghai, 200433, China
| | - Panagoula Oikonomou
- Surgery Department, Democritus University of Thrace, Alexandroupolis, Greece
| | - Christina Nikolaou
- Surgery Department, Democritus University of Thrace, Alexandroupolis, Greece
| | | | | | | | - Savvas Petanidis
- Department of Medicine, Laboratory of Medical Biology & Genetics, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Christoforos Kosmidis
- 3rd University Surgery Department, "AHEPA" University Hospital, Thessaloniki, Greece
| | | | - Wolfgang Hohenforst-Schmidt
- Department of Cardiology/Pulmonology/Intensive Care/Nephrology, Sana Clinic Group Franken, "Hof" Clinics, University of Erlangen, Hof, Germany
| | - Nikos Kougkas
- Rheumatology Department, Ippokrateio University General Hospital, Thessaloniki, Greece
| | - Chrysanthi Sardeli
- Department of Pharmacology & Clinical Pharmacology, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
3
|
Stetten AZ, Golovko DS, Weber SAL, Butt HJ. Slide electrification: charging of surfaces by moving water drops. SOFT MATTER 2019; 15:8667-8679. [PMID: 31528956 DOI: 10.1039/c9sm01348b] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We investigate the charge separation caused by the motion of a water drop across a hydrophobic, insulating solid surface. Although the phenomenon of liquid charging has been consistently reported, these reports are primarily observational, results are difficult to reproduce, and no quantitative theory has been developed. In this work, we address both the experimental and theoretical sides of this problem. We reproducibly measure the charge gained by water drops sliding down a substrate, and we outline an analytical theory to describe this charging process. As an experimental system, we choose water drops moving down an inclined plane of glass hydrophobized with perfluoro octadecyltrichlorosilane (PFOTS). On this surface, sliding drops gain a positive charge. We observe charge saturation in three variables: increasing drop number, increasing interval between drops, and increasing drop-sliding length. These charge saturations indicate a limited "storage capacity" of the system, as well as a gradual discharging of the surface. To explain these results, we theorize that some fraction of the charge in the Debye layer is transferred to the surface rather than being neutralized as the drop passes. This fraction, or "transfer coefficient", is dependent on the electric potentials of surface and drop. All of our experimental charge saturation results can be interpreted based on the proposed theory. Given that nearly every surface in our lives comes in contact with water, this water-dependent surface charging may be a ubiquitous process that we can begin to understand through the proposed theory.
Collapse
Affiliation(s)
- Amy Z Stetten
- Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz, Germany.
| | - Dmytro S Golovko
- Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz, Germany.
| | - Stefan A L Weber
- Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz, Germany. and Department of Physics, Johannes Gutenberg University, Staudingerweg 10, 55128 Mainz, Germany
| | - Hans-Jürgen Butt
- Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz, Germany.
| |
Collapse
|
4
|
Stein SW, Rasmussen J, Walls S, Schultz DW, Oakley C, Drake JB. The Influence of Electrostatic Controls on MDI Size Distribution Measurements. AAPS PharmSciTech 2019; 20:170. [PMID: 31004248 DOI: 10.1208/s12249-019-1354-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 02/23/2019] [Indexed: 11/30/2022] Open
Abstract
Cascade impactor testing is widely used to characterize the aerodynamic particle-size distribution of metered dose inhaler aerosols. Charge is often imparted to MDI aerosols by triboelectrification as formulation rapidly travels through the valve stem and actuator during atomization. The presence of charge on MDI aerosols can impact the accuracy and reproducibility of APSD measurements made using cascade impactors. The aerodynamic particle size distribution of three different experimental MDI formulations were evaluated using the Next Generation Impactor with and without incorporating static controls during testing. The static controls included grounding the analyst and the equipment, using an ionizing air blower and anti-static gun, rinsing and allowing the actuator to air dry prior to testing, and having the analyst not wear gloves or touch the USP throat during testing. For all three formulations, tests that used static controls had lower actuator and throat deposition and correspondingly higher deposition on the impactor stages. While static controls influenced the amount of drug entering into the impactor during testing, the static controls did not otherwise change the aerodynamic particle size distribution of these particles. Static controls had the greatest impact on the ethanol-free HFA-227 formulation. For this formulation, there was a 15% difference in throat deposition for the tests that did or did not incorporate static controls. These results demonstrated that electrostatic effects can lead to meaningful variability in cascade impactor test results. Static controls should be considered when developing cascade impactor test methods for MDI products in order to eliminate variability in test results.
Collapse
|
5
|
Martin AR, Moore CP, Finlay WH. Models of deposition, pharmacokinetics, and intersubject variability in respiratory drug delivery. Expert Opin Drug Deliv 2018; 15:1175-1188. [PMID: 30388902 DOI: 10.1080/17425247.2018.1544616] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
INTRODUCTION Aerosol drug delivery to the lungs via inhalation is widely used in the treatment of respiratory diseases. The deposition pattern of inhaled particles within the airways of the respiratory tract is key in determining the initial delivered dose. Thereafter, dose-dependent processes including drug release or dissolution, clearance, and absorption influence local and systemic exposure to inhaled drugs over time. AREAS COVERED Empirical correlations, numerical simulation, and in vitro airway geometries that permit improved prediction of extrathoracic and lung deposition fractions in a variety of age groups and breathing conditions are described. Efforts to link deposition models with pharmacokinetic models predicting lung and systemic exposure to inhaled drugs over time are then reviewed. Finally, new methods to predict intersubject variability in extrathoracic deposition, capturing variability in both size and shape of the upper airways, are highlighted. EXPERT OPINION Recent work has been done to expand in vitro deposition experiments to a wide range of age groups and breathing conditions, to link regional lung deposition models with pharmacokinetic models, and to improve prediction of intersubject variability. These efforts are improving predictive understanding of respiratory drug delivery, and will aid the development of new inhaled drugs and delivery devices.
Collapse
Affiliation(s)
- Andrew R Martin
- a Department of Mechanical Engineering , University of Alberta , Edmonton , AB , Canada
| | - Charles P Moore
- a Department of Mechanical Engineering , University of Alberta , Edmonton , AB , Canada
| | - Warren H Finlay
- a Department of Mechanical Engineering , University of Alberta , Edmonton , AB , Canada
| |
Collapse
|
6
|
Pharmaceutical aerosol electrostatics: a field with much potential for development. Ther Deliv 2015; 6:105-7. [PMID: 25690079 DOI: 10.4155/tde.14.96] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
7
|
Abstract
We showed previously that a 30% blood loss in rats, without resuscitation, caused significant accumulation of microthrombi and leukocytes within the pulmonary circulation by 24 h. We hypothesized that the microthrombi formed spontaneously as a consequence of hemorrhage-induced stasis within the low-pressure pulmonary circuit and that the leukocytes were attracted to them. This suggested that elimination of the microthrombi, using an inhaled thrombolytic agent, could prevent the neutrophil sequestration after blood loss. To test this hypothesis, we removed 30% of the calculated blood volume from isoflurane-anesthetized, male Sprague-Dawley rats (350-500 g) over 5 min and allowed them to recover. Six hours later, we re-anesthetized the rats and nebulized tissue plasminogen activator (80 or 320 µg/kg), lactated Ringer's solution (LRS), or ipratropium bromide (i-bromide) into their lungs. We used i-bromide as a control after we discovered that nebulized LRS had thrombolytic properties. At 24 h, we removed and fixed the lungs and prepared sections for immunohistochemistry using antibodies against fibrinogen (microthrombi) and CD16 (leukocytes). Digital images of each section were obtained using a confocal microscope. Pixel counts of the images showed significantly less accumulation of microthrombi and leukocytes in lungs nebulized with tissue plasminogen activator or LRS than in non-nebulized lungs or in lungs nebulized with i-bromide (P ≤ 0.05). Lactated Ringer's solution becomes positively charged when nebulized (unlike i-bromide), suggesting that it eliminated microthrombi by fibrin depolymerization. We confirmed this using an in vitro assay. Our results demonstrate that lyses of microthrombi that accumulate in the lung after acute blood loss prevent subsequent leukocyte sequestration.
Collapse
|
8
|
Tsai CSJ. Characterization of Airborne Nanoparticle Loss in Sampling Tubing. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2015; 12:D161-D167. [PMID: 25746064 DOI: 10.1080/15459624.2015.1019077] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Airborne nanoparticle release has been studied extensively lately using a variety of instruments and nanoparticle loss data for the instrument sampling tubes were required. This study used real-time measurements to characterize particle losses. Particle concentrations were measured by Fast Mobility Particle Sizer (FMPS). Electrically conductive and Tygon sampling tubes 7.7 mm I.D. and 2.0, 4.9, 7.0, and 8.4 m long, were used to analyze particle losses. Two different sources of nearly steady-state particles-atmospheric nanoparticles (maximum concentration of 4,000-6,000 particle/cm(3)) and nebulizer-generated salt aerosols (maximum concentration of 14,000-16,000 particle/cm(3))-were utilized. For all test conditions, a reduction in particle number concentration was observed and found to be proportional to tube length for particle diameter (dp) less than 40 nm. A maximum loss up to 30% was found for the longest tube length (8.4 m) at particle size of approximately 8 nm. For particles from 40 to 400 nm, the losses were less than 3%. Measured particle losses were greater than predicted by theory for the smallest particles. The two types of tubing showed similar particle losses for both test aerosols. Particle losses were low for dp greater than 40 nm, and for all particle sizes when the tube length was less than 2 m.
Collapse
Affiliation(s)
- Candace Su-Jung Tsai
- a School of Health Science, Birck Nanotechnology Center, Purdue University , West Lafayette , Indiana
| |
Collapse
|
9
|
Abstract
INTRODUCTION Nebulizers are the oldest modern method of delivering aerosols to the lungs for the purpose of respiratory drug delivery. While use of nebulizers remains widespread in the hospital and home setting, certain newer nebulization technologies have enabled more portable use. Varied fundamental processes of droplet formation and breakup are used in modern nebulizers, and these processes impact device performance and suitability for nebulization of various formulations. AREAS COVERED This review first describes basic aspects of nebulization technologies, including jet nebulizers, various high-frequency vibration techniques, and the use of colliding liquid jets. Nebulizer use in hospital and home settings is discussed next. Complications in aerosol droplet size measurement owing to the changes in nebulized droplet diameters due to evaporation or condensation are discussed, as is nebulization during mechanical ventilation. EXPERT OPINION While the limelight may often appear to be focused on other delivery devices, such as pressurized metered dose and dry powder inhalers, the ease of formulating many drugs in water and delivering them as aqueous aerosols ensures that nebulizers will remain as a viable and relevant method of respiratory drug delivery. This is particularly true given recent improvements in nebulizer droplet production technology.
Collapse
Affiliation(s)
- Andrew R Martin
- University of Alberta, Department of Mechanical Engineering , Edmonton, Alberta, T6G 2G8 , Canada
| | | |
Collapse
|
10
|
Pitsiou G, Zarogoulidis P, Petridis D, Kioumis I, Lampaki S, Organtzis J, Porpodis K, Papaiwannou A, Tsiouda T, Hohenforst-Schmidt W, Kakolyris S, Syrigos K, Huang H, Li Q, Turner JF, Zarogoulidis K. Inhaled tyrosine kinase inhibitors for pulmonary hypertension: a possible future treatment. DRUG DESIGN DEVELOPMENT AND THERAPY 2014; 8:1753-63. [PMID: 25336919 PMCID: PMC4199972 DOI: 10.2147/dddt.s70277] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Pulmonary hypertension is a disease with severe consequences for the human body. There are several diseases and situations that induce pulmonary hypertension and are usually underdiagnosed. Treatments include conventional medical therapies and oral, inhaled, intravenous, and subcutaneous options. Depending on its severity, heart or lung transplant may also be an option. A possible novel treatment could be tyrosine kinase inhibitors. We conducted experiments with three jet nebulizers and three ultrasound nebulizers with erlotinib, gefitinib, and imatinib. Different residual cup designs and residual cup loadings were used in order to identify the best combination to produce droplets of less than 5 μm in mass median aerodynamic diameter. We found that gefitinib could not be transformed into a powder, so conversion to an aerosol form was not possible. Our experiments indicated that imatinib is superior to erlotinib with regard to small droplet size formation using both inhaled technologies (1.37 μm <2.23 μm and 1.92 μm <3.11 μm, jet and ultrasound, respectively) and, at jet devices (1.37 μm <1.92 μm). Cup designs C and G contribute best to small droplet creation uniquely supporting and equally well the activity of both drugs. The disadvantage of the large droplets formed for erlotinib was offset when combined with residual cup C (1.37 μm instead of 2.23 μm). At a 2 mL dose, the facemask and cone mouthpieces performed best and evenly; the facemask and low dose were the best choice (2.08 μm and 2.12 μm, respectively). Erlotinib and imatinib can be administered as an aerosols, and further in vivo experimentation is necessary to investigate the positive effects of these drugs in the treatment of pulmonary hypertension.
Collapse
Affiliation(s)
- Georgia Pitsiou
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Paul Zarogoulidis
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Dimitris Petridis
- Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute, Thessaloniki, Greece
| | - Ioannis Kioumis
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Sofia Lampaki
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - John Organtzis
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Konstantinos Porpodis
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Antonis Papaiwannou
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Theodora Tsiouda
- Internal Medicine Department, Thegenio Anticancer Hospital, Thessaloniki, Greece
| | | | - Stylianos Kakolyris
- Oncology Department, Sotiria Hospital of Chest Diseases, University of Athens, Athens, Greece
| | - Konstantinos Syrigos
- Oncology Department, University General Hospital of Alexandroupolis, Democritus University of Thrace, Alexandroupolis, Greece
| | - Haidong Huang
- Department of Respiratory Diseases, Changhai Hospital/First Affiliated Hospital of the Second Military Medical University, Shanghai, People's Republic of China
| | - Qiang Li
- Department of Respiratory Diseases, Changhai Hospital/First Affiliated Hospital of the Second Military Medical University, Shanghai, People's Republic of China
| | - J Francis Turner
- Division of Interventional Pulmonology and Medical Oncology, Cancer Treatment Centers of America, Western Regional Medical Center, Goodyear, AZ, USA
| | - Konstantinos Zarogoulidis
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
11
|
Zarogoulidis P, Kioumis I, Lampaki S, Organtzis J, Porpodis K, Spyratos D, Pitsiou G, Petridis D, Pataka A, Huang H, Li Q, Yarmus L, Hohenforst-Schmidt W, Pezirkianidis N, Zarogoulidis K. Optimization of nebulized delivery of linezolid, daptomycin, and vancomycin aerosol. DRUG DESIGN DEVELOPMENT AND THERAPY 2014; 8:1065-72. [PMID: 25143711 PMCID: PMC4136957 DOI: 10.2147/dddt.s66576] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND At this time, several antibiotics have been investigated as possibilities for aerosol administration, but local therapy has been found to be more efficient in several diseases. MATERIALS AND METHODS The drugs linezolid (Zyvox), vancomycin (Voncon), and daptomycin (Cubicin) were tested with three jet nebulizers with seven different residual cups and different loadings. Moreover, three ultrasound nebulizers were again tested with these drugs, with different loadings and mouthpiece attachments. RESULTS When drugs are combined with particular cup designs, they significantly lower the droplet size to 1.60 and 1.80 μm, which represents the best combination of Zyvox and cup G and Cubicin and cup D, respectively. Cup design D is suggested as the most effective cup for lowering the droplet size (2.30 μm) when considering a higher loading level (8 mL). CONCLUSION Modification of current drugs from dry powder to solution is possible, and the residual cup design plays the most important role in droplet size production when the nebulization systems have the same properties.
Collapse
Affiliation(s)
- Paul Zarogoulidis
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Ioannis Kioumis
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Sofia Lampaki
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - John Organtzis
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Konstantinos Porpodis
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Dionysios Spyratos
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Georgia Pitsiou
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Dimitris Petridis
- Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute, Thessaloniki, Greece
| | - Athanasia Pataka
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Haidong Huang
- Department of Respiratory Diseases, Shanghai Hospital, II Military University Hospital, Shanghai, People's Republic of China
| | - Qiang Li
- Department of Respiratory Diseases, Shanghai Hospital, II Military University Hospital, Shanghai, People's Republic of China
| | - Lonny Yarmus
- Division of Pulmonary and Critical Care Medicine, Johns Hopkins University, Baltimore, MD, USA
| | | | | | - Konstantinos Zarogoulidis
- Pulmonary Department-Oncology Unit, "G Papanikolaou" General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
12
|
The Influence of Actuator Materials and Nozzle Designs on Electrostatic Charge of Pressurised Metered Dose Inhaler (pMDI) Formulations. Pharm Res 2013; 31:1325-37. [DOI: 10.1007/s11095-013-1253-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Accepted: 11/10/2013] [Indexed: 11/26/2022]
|
13
|
Zarogoulidis P, Kioumis I, Porpodis K, Spyratos D, Tsakiridis K, Huang H, Li Q, Turner JF, Browning R, Hohenforst-Schmidt W, Zarogoulidis K. Clinical experimentation with aerosol antibiotics: current and future methods of administration. DRUG DESIGN DEVELOPMENT AND THERAPY 2013; 7:1115-34. [PMID: 24115836 PMCID: PMC3793595 DOI: 10.2147/dddt.s51303] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Currently almost all antibiotics are administered by the intravenous route. Since several systems and situations require more efficient methods of administration, investigation and experimentation in drug design has produced local treatment modalities. Administration of antibiotics in aerosol form is one of the treatment methods of increasing interest. As the field of drug nanotechnology grows, new molecules have been produced and combined with aerosol production systems. In the current review, we discuss the efficiency of aerosol antibiotic studies along with aerosol production systems. The different parts of the aerosol antibiotic methodology are presented. Additionally, information regarding the drug molecules used is presented and future applications of this method are discussed.
Collapse
Affiliation(s)
- Paul Zarogoulidis
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece ; Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University Duisburg-Essen, Essen, Germany
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Abstract
Electrostatics continues to play an important role in pharmaceutical aerosols for inhalation. Despite its ubiquitous nature, the charging process is complex and not well understood. Nonetheless, significant advances in the past few years continue to improve understanding and lead to better control of electrostatics. The purpose of this critical review is to present an overview of the literature, with an emphasis on how electrostatic charge can be useful in improving pulmonary drug delivery.
Collapse
|
15
|
Establishing the optimal nebulization system for paclitaxel, docetaxel, cisplatin, carboplatin and gemcitabine: back to drawing the residual cup. Int J Pharm 2013; 453:480-7. [PMID: 23769993 DOI: 10.1016/j.ijpharm.2013.06.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Revised: 06/06/2013] [Accepted: 06/10/2013] [Indexed: 11/21/2022]
Abstract
BACKGROUND Chemotherapy drugs have still the major disadvantage of non-specific cytotoxic effects. Although, new drugs targeting the genome of the tumor are already in the market, doublet chemotherapy regimens still remain the cornerstone of lung cancer treatment. Novel modalities of administration are under investigation such as; aerosol, intratumoral and intravascular. MATERIALS AND METHODS In the present study five chemotherapy drugs; paclitaxel, docetaxel, gemcitabine, carboplatin and cisplatin were nebulized with three different jet nebulizers (Maxineb(®), Sunmist(®), Invacare(®)) and six different residual cups at different concentrations. The purpose of the study was to identify the "ideal" combination of nebulizer-residual cup design-drug-drug loading for a future concept of aerosol chemotherapy in lung cancer patients. The Mastersizer(®) 2000 was used to evaluate the aerosol droplet mass median aerodynamic diameter. RESULTS The drug, nebulizer and residual cup design greatly influences the producing droplet size (p<0.005, in each case). However; the design of the residual cup is the most important factor affecting the produced droplet size (F=834.6, p<0.001). The drug loading plays a vital role in the production of the desired droplet size (F=10.42, p<0.001). The smallest droplet size was produced at 8 ml loading (1.26 μm), while it remained the same at 2, 4 and 6 mls of drug loading. CONCLUSION The ideal nebulizer would be Maxineb(®), with a large residual cup (10 ml maximum loading capacity) and 8 mls loading and the drug with efficient pulmonary deposition would be docetaxel.
Collapse
|
16
|
Chan JGY, Traini D, Chan HK, Young PM, Kwok PCL. Delivery of High Solubility Polyols by Vibrating Mesh Nebulizer to Enhance Mucociliary Clearance. J Aerosol Med Pulm Drug Deliv 2012; 25:297-305. [DOI: 10.1089/jamp.2011.0961] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- John Gar Yan Chan
- Faculty of Pharmacy, The University of Sydney, Sydney, NSW, Australia
| | - Daniela Traini
- Faculty of Pharmacy, The University of Sydney, Sydney, NSW, Australia
| | - Hak-Kim Chan
- Faculty of Pharmacy, The University of Sydney, Sydney, NSW, Australia
| | - Paul M. Young
- Faculty of Pharmacy, The University of Sydney, Sydney, NSW, Australia
| | - Philip Chi Lip Kwok
- Department of Pharmacology & Pharmacy, The University of Hong Kong, Hong Kong SAR, People's Republic of China
| |
Collapse
|
17
|
Chan JGY, Kwok PCL, Young PM, Chan HK, Traini D. Mannitol Delivery by Vibrating Mesh Nebulisation for Enhancing Mucociliary Clearance. J Pharm Sci 2011; 100:2693-702. [DOI: 10.1002/jps.22494] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2010] [Revised: 12/01/2010] [Accepted: 01/05/2010] [Indexed: 11/10/2022]
|