1
|
Dissanayake S, Mundin G, Woodward J, Lomax M, Dalvi P. Pharmacokinetic and Pharmacodynamic Comparison of Fluticasone Propionate/Formoterol Fumarate Administered via a Pressurized Metered-Dose Inhaler and a Novel Breath-Actuated Inhaler in Healthy Volunteers. J Aerosol Med Pulm Drug Deliv 2023; 36:65-75. [PMID: 36796001 DOI: 10.1089/jamp.2022.0064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023] Open
Abstract
Introduction: Fluticasone propionate/formoterol fumarate (fluticasone/formoterol) exposures, following administration of Flutiform® K-haler®, a breath-actuated inhaler (BAI), were compared with the Flutiform pressurized metered-dose inhaler (pMDI) with/without spacer in two healthy volunteer studies. In addition, formoterol-induced systemic pharmacodynamic (PD) effects were examined in the second study. Methods: Study 1: single-dose, three-period, crossover pharmacokinetic (PK) study with oral charcoal administration. Fluticasone/formoterol 250/10 μg was administered via BAI, pMDI, or pMDI with spacer (pMDI+S). Pulmonary exposure for BAI was deemed no less than for pMDI (primary comparator) if the lower limit of 94.12% confidence intervals (CIs) for BAI:pMDI maximum plasma concentration (Cmax) and area under the plasma concentration-time curve (AUCt) ratios was ≥80%. Study 2: two-stage adaptive design, both stages being single-dose, crossover without charcoal administration. The PK stage compared fluticasone/formoterol 250/10 μg via BAI, pMDI, or pMDI+S. The primary comparisons were as follows: BAI versus pMDI+S for fluticasone and BAI versus pMDI for formoterol. Systemic safety with BAI was deemed no worse than primary comparator if the upper limit of 94.12% CIs for Cmax and AUCt ratios was ≤125%. PD assessment was to be conducted if BAI safety was not confirmed in the PK stage. Based on PK results, only formoterol PD effects were evaluated. The PD stage compared fluticasone/formoterol 1500/60 μg via BAI, pMDI, or pMDI+S; fluticasone/formoterol 500/20 μg pMDI; and formoterol 60 μg pMDI. The primary endpoint was maximum reduction in serum potassium within 4 hours postdose. Equivalence was defined as 95% CIs for BAI versus pMDI+S and pMDI ratios within 0.5-2.0. Results: Study 1: lower limit of 94.12% CIs for BAI:pMDI ratios >80%. Study 2, PK stage: upper limit of 94.12% CIs for fluticasone (BAI:pMDI+S) ratios <125%; upper limit of 94.12% CIs for formoterol (BAI:pMDI) ratios >125% (for Cmax, not AUCt). Study 2, PD stage: 95% CIs for serum potassium ratios 0.7-1.3 (BAI:pMDI+S) and 0.4-1.5 (BAI:pMDI). Conclusions: Fluticasone/formoterol BAI performance was within the range observed for the pMDI with/without a spacer. Sponsor: Mundipharma Research Ltd. EudraCT 2012-003728-19 (Study 1) and 2013-000045-39 (Study 2).
Collapse
Affiliation(s)
| | - Gill Mundin
- Mundipharma Research Limited, Cambridge, United Kingdom
| | - Jo Woodward
- Mundipharma Research Limited, Cambridge, United Kingdom
| | - Mark Lomax
- Mundipharma Research Limited, Cambridge, United Kingdom
| | | |
Collapse
|
2
|
Valero AL, Trigueros JA, Plaza V. Multidisciplinary consensus on inhaled therapy in asthma. Expert Rev Respir Med 2020; 15:425-434. [PMID: 33170733 DOI: 10.1080/17476348.2021.1841639] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Asthma is managed by health professionals from different specialties. We aim to reach a consensus on the optimal use of inhaled therapy and the initial steps of asthma treatment, taking into account the opinions of the involved specialists. METHODS A modified Delphi approach was used. A scientific committee provided 52 controversial statements, which were submitted to primary care physicians, allergists, and pulmonologists. Discrepancies among specialties were evaluated. RESULTS A total of 209 specialists completed the questionnaire (20.2 ± 9.3 years of asthma management experience). A consensus was reached on 37 statements (71.1%), discrepancies among specialties were found in 14. The most recommended maintenance treatment for mild persistent asthma in adults/adolescents was low-dose-inhaled corticosteroids daily. MART (Maintenance and Reliever Therapy) was recommended as salvage treatment for moderate persistent asthma. Panelists agreed on the most frequent critical errors with pressurized Metered-Dose Inhalers or Dry-Powder Inhalers, and considered that Breath-Actuated Inhalers are a suitable option for all patients with the ability to inhale voluntarily. CONCLUSIONS The experts endorse the main guidelines recommendations; however, do not fully agree on recent GINA recommendations about the treatment of the initial steps of the disease. The experts value positively the differential characteristics of BAI over other devices.
Collapse
Affiliation(s)
- Antonio L Valero
- Allergy Unit, Pneumology Department, Hospital Clínic, IDIBAPS, CIBER de Enfermedades Respiratorias (CIBERES), Barcelona, Spain
| | | | - Vicente Plaza
- Department of Respiratory Medicine, Hospital de la Santa Creu i Sant Pau, Institut d'Investigació Biomédica Sant Pau (IIB Sant Pau), Department of Medicine, Universitat Autònoma de Barcelona, Barcelona, Spain
| |
Collapse
|
3
|
Inhaled Formoterol-Fluticasone Single Inhaler Therapy in Asthma: Real-World Efficacy, Budget Impact, and Potential to Improve Adherence. Can Respir J 2020; 2020:8631316. [PMID: 33005277 PMCID: PMC7509561 DOI: 10.1155/2020/8631316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 08/21/2020] [Accepted: 09/07/2020] [Indexed: 11/18/2022] Open
Abstract
Asthma is the commonest chronic disease affecting airways in humans and has an increasing global disease burden. Inhaled corticosteroids (ICS) are the first-line therapeutic option for asthma, and addition of a long-acting beta 2-agonist (LABA) has been shown to improve asthma control. A combination of the two agents in a single inhaler is beneficial with regard to ease of administration and patient compliance. Various ICS-LABA formulations are available across various countries in the world, one among them being formoterol-fluticasone. Both formoterol and fluticasone have pharmacologic peculiarities which places the combination in a uniquely advantageous position when it comes to asthma therapy. The present review focuses on some of the, hitherto, less explored aspects of this combination inhaler such as real-world efficacy, impact on budget allocation, results of switch-over therapy, and potential to improve adherence to asthma treatment. It also provides practical recommendations on positioning it in real-world asthma management.
Collapse
|
4
|
Morais-Almeida M, Pité H, Cardoso J, Costa R, Cordeiro CR, Silva E, Todo-Bom A, Vicente C, Marques JA. Asthma management with breath-triggered inhalers: innovation through design. Asthma Res Pract 2020; 6:4. [PMID: 32518663 PMCID: PMC7275490 DOI: 10.1186/s40733-020-00057-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Accepted: 05/25/2020] [Indexed: 11/24/2022] Open
Abstract
Background Asthma affects the lives of hundred million people around the World. Despite notable progresses in disease management, asthma control remains largely insufficient worldwide, influencing patients’ wellbeing and quality of life. Poor patient handling of inhaling devices has been identified as a major persistent problem that significantly reduces inhaled drugs’ efficacy and is associated with poor adherence to treatment, impairing clinical results such as asthma control and increasing disease-related costs. We herein review key research and development (R&D) innovation in inhaler devices, highlighting major real-world critical errors in the handling and inhalation technique with current devices and considering potential solutions. Furthermore, we discuss current evidence regarding breath-triggered inhalers (BTI). Main body The two most common significant problems with inhalers are coordinating actuation and inhalation with pressurized metered-dose inhalers (pMDIs), and the need to inhale forcibly with a dry powder inhaler. BTI R&D plans were designed to overcome these problems. Its newest device k-haler® has several other important features, generating a less forceful aerosol plume than previous pMDIs, with efficient drug delivery and lung deposition, even in patients with low inspiratory flow. The local and systemic bioavailability of fluticasone propionate and formoterol (FP/FORM) administered via k-haler® has been shown to be therapeutically equivalent when administered via the previous FP/FORM pMDI. This device requires very few steps and has been considered easy to use (even at first attempt) and preferred by the patients in a randomized crossover study. In our country, FP/FORM k-haler is available without additional costs compared to FP/FORM pMDI. All devices continue to require education and regular checking of the correct inhalation technique. Conclusion BTI R&D can bring advantage over current available inhalers, avoiding the two most common identified critical errors in inhalation technique. K-haler® BTI is currently available, without an increased cost, and approved for adolescents and adults with asthma in whom treatment with inhaled combined therapy with long-acting beta2-agonists and corticosteroids is indicated. Its attractive and practical design to facilitate its use has been awarded. K-haler® represents added value through innovation to fulfill actual asthma patient needs, thus with potential relevant impact in asthma management and effective control.
Collapse
Affiliation(s)
| | - Helena Pité
- Allergy Center, CUF Descobertas Hospital and CUF Infante Santo Hospital, Lisbon, Portugal.,CEDOC (Chronic Diseases Research Center), NOVA Medical School, Universidade NOVA de Lisboa, Lisbon, Portugal
| | - João Cardoso
- Pulmonology Department, Centro Hospitalar de Lisboa Central, Lisbon, Portugal.,NOVA Medical School, Universidade NOVA de Lisboa, Lisbon, Portugal
| | - Rui Costa
- Family Medicine, Porto, Portugal.,GRESP (Grupo de Estudos de Doenças Respiratórias da APMGF), Lisbon, Portugal
| | - Carlos Robalo Cordeiro
- Pulmonology Department, Centro Hospitalar Universitário de Coimbra, Coimbra, Portugal.,Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | - Eurico Silva
- Family Medicine USF João Semana, Aveiro, Ovar, Portugal.,GRESP Inhalers and Tecnhical Devices Working Group, Lisbon, Portugal
| | - Ana Todo-Bom
- Immunoallergology Department, Centro Hospitalar Universitário de Coimbra, Coimbra, Portugal.,Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | - Cláudia Vicente
- Family Medicine UCSP Soure, Coimbra, Portugal.,GRESP (Grupo de Estudos de Doenças Respiratórias da APMGF), Lisbon, Portugal
| | - José Agostinho Marques
- Pulmonology Department, Centro Hospitalar de São João, Porto, Portugal.,Faculty of Medicine, University of Porto, Porto, Portugal
| |
Collapse
|
5
|
Morais-Almeida M, Pité H, Cardoso J, Costa R, Robalo Cordeiro C, Silva E, Todo-Bom A, Vicente C, Agostinho Marques J. Strengths of breath-triggered inhalers in asthma management. Pulmonology 2020; 26:327-329. [PMID: 32474058 DOI: 10.1016/j.pulmoe.2020.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 04/25/2020] [Accepted: 04/28/2020] [Indexed: 11/24/2022] Open
Affiliation(s)
| | - H Pité
- Allergy Center, CUF Descobertas Hospital and CUF Infante Santo Hospital, Lisboa, Portugal; CEDOC (Chronic Diseases Research Center), NOVA Medical School, Lisboa, Portugal
| | - J Cardoso
- Pulmonology Department, Centro Hospitalar de Lisboa Central, Lisboa, Portugal; NOVA Medical School, Lisboa, Portugal
| | - R Costa
- Family Medicine, Porto, Portugal; Coordinator of GRESP (Grupo de Estudos de Doenças Respiratórias da APMGF), Portugal
| | - C Robalo Cordeiro
- Pulmonology Department, Centro Hospitalar Universitário de Coimbra, Portugal; Faculty of Medicine, University of Coimbra, Portugal
| | - E Silva
- Family Medicine USF João Semana, Ovar, Aveiro, Portugal; Coordinator of GRESP Inhalers and Technical Devices Working Group, Portugal
| | - A Todo-Bom
- Immunoallergology Department, Centro Hospitalar Universitário de Coimbra, Portugal; Faculty of Medicine, University of Coimbra, Portugal
| | - C Vicente
- Family Medicine UCSP Soure, Coimbra, Portugal; Secretary of GRESP (Grupo de Estudos de Doenças Respiratórias da APMGF), Portugal
| | - J Agostinho Marques
- Pulmonology Department, Centro Hospitalar de São João, Porto, Portugal; Faculty of Medicine, University of Porto, Portugal
| |
Collapse
|
6
|
Lavorini F, Bianco A, Blasi F, Braido F, Corsico AG, Di Marco F, Gentile A, Paggiaro PL, Pegoraro V, Pelaia G, Rogliani P, Santus P, Scichilone N, Soldi A, Canonica GW. What drives inhaler prescription for asthma patients? Results from a real-life retrospective analysis. Respir Med 2020; 166:105937. [PMID: 32250870 DOI: 10.1016/j.rmed.2020.105937] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 02/27/2020] [Accepted: 03/17/2020] [Indexed: 01/05/2023]
Abstract
BACKGROUND The choice of inhaler device for asthma patients depends upon multiple attributes. We investigated factors that may drive general practitioners (GPs) and respiratory specialists in the prescription of inhaler devices for asthma patients who initiated inhalation therapy. METHODS We retrospectively analysed prescriptions by GPs and respiratory specialists to asthma patients commencing inhaled corticosteroid/long-acting β2-agonist combination therapy available as both pressurised metered-dose inhalers (pMDIs) and dry powder inhalers (DPIs). Patient characteristics were compared by device and multivariate analysis was used to model the likelihood of receiving a pMDI as opposed to a DPI in order to identify drivers for prescription. A sample of the respiratory specialists completed an ad-hoc survey of their perceived success in achieving asthma control in their patients and barriers to attaining full control. RESULTS Prescription of a particular inhaler device was unrelated to the characteristics of the patients. Multivariate analysis revealed that the main driver for the choice of inhaler device was the medication (Odds Ratio and 95% Confidence Interval, respectively for GPs and specialists: 0.19 [0.16-0.23]; 0.17 [0.08-0.37]). Specialists perceived asthma as being inadequately controlled in 41% of their patients, and considered patients' difficulties in using DPIs and pMDIs as instrumental in this, citing a need for a novel, more effective inhaler technology. CONCLUSION Physicians choose inhaler devices according to the prescribed drugs and not to the characteristics of the individual patient. This may reflect a lack of confidence in existing inhaler devices and underlines the need for technologies, which are more reliable and easier to use by patients.
Collapse
Affiliation(s)
- F Lavorini
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy.
| | - A Bianco
- Department of Translational Medical Sciences, University of Campania "L. Vanvitelli", Naples, Italy
| | - F Blasi
- Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico Internal Medicine Department, Respiratory Unit and Adult Cystic Fibrosis Center, Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Milan, Italy
| | - F Braido
- Department of Internal Medicine, Respiratory Diseases and Allergy Clinic, University of Genova, Azienda Policlinico IRCCs San Martino, Genoa, Italy
| | - A G Corsico
- Division of Respiratory Diseases, IRCCS Policlinico San Matteo Foundation - Department of Internal Medicine and Therapeutics, University of Pavia, Pavia, Italy
| | - F Di Marco
- Department of Health Sciences, University of Milan, Italy - Respiratory Unit, Papa Giovanni XXIII Hospital, Bergamo, Italy
| | - A Gentile
- Mundipharma Pharmaceuticals, Milan, Italy
| | - P L Paggiaro
- Department of Surgery, Medicine, Molecular Biology and Critical Care, University of Pisa, Pisa, Italy
| | | | - G Pelaia
- Department of Medical and Surgical Sciences, University "Magna Graecia" of Catanzaro, Catanzaro, Italy
| | - P Rogliani
- Respiratory Medicine Department of Experimental Medicine, University of Rome "Tor Vergata" - Respiratory Unit, Policlinico Tor Vergata, Rome, Italy
| | - P Santus
- Department of Biomedical and Clinical Sciences (DIBIC) - University of Milan. Division of Respiratory Diseases - "L. Sacco" University Hospital - ASST Fatebenefratelli Sacco - Milan, Italy
| | - N Scichilone
- PROMISE Department, University of Palermo, Palermo, Italy
| | - A Soldi
- Mundipharma Pharmaceuticals, Milan, Italy
| | - G W Canonica
- Personalized Medicine, Asthma and Allergy Clinic, Humanitas Research Hospital - Department of Biomedical Sciences, Humanitas University, Milan, Italy
| |
Collapse
|
7
|
Usmani O, Roche N, Marshall J, Danagher H, Price D. An innovative corticosteroid/long-acting β 2-agonist breath-triggered inhaler: facilitating lung delivery of fluticasone propionate/formoterol fumarate for the treatment of asthma. Expert Opin Drug Deliv 2019; 16:1367-1380. [PMID: 31752560 DOI: 10.1080/17425247.2019.1689957] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Introduction: Incorrect inhaler technique is one reason why the efficacies of inhaled asthma treatments in clinical trials and effectiveness in the real world differ. Inhaler technique is critical for drug delivery to the lungs; incorrect technique negatively impacts asthma control and long-term outcomes. Breath-triggered inhalers (BTIs) can simplify drug administration and are suitable for most patients, including those with reduced inspiratory flow. Until recently, no inhaled corticosteroid/long-acting β2-agonist combination BTI was available in Europe. The flutiform® (fluticasone propionate/formoterol fumarate [FP/FORM]) k-haler® is the first combination BTI now approved in Europe for asthma maintenance treatment.Areas covered: We review studies examining the challenges posed to patients by different inhaler types and explore evidence demonstrating the clinical efficacy of FP/FORM administered via a pressurized metered-dose inhaler. We also review the pharmacokinetic/pharmacodynamic studies supporting FP/FORM k-haler use, and consider data showing high lung deposition with the device. Finally, we review patient experiences using the BTI, device characteristics, and health economic aspects.Expert opinion: Despite the availability of therapies, asthma control levels remain low, and there is a clear need for easy-to-use inhalers. Research to increase our understanding of critical errors with each inhaler and how to overcome them is important for improving care.Abbreviations: AUCt: area under the plasma concentration-time curve from the time of dosing to the last measurable concentration; BDP: beclometasone dipropionate; BTI: breath-triggered inhaler; BUD: budesonide; CI: confidence interval; Cmax: maximum observed plasma concentration; DPI: dry powder inhaler; FDC: fixed-dose combination; FEV1: forced expiratory volume in 1 s; FORM: formoterol fumarate; FP: fluticasone propionate; HCP: health-care professional; ICS: inhaled corticosteroid; LABA: long-acting β2-agonist; OR: odds ratio; PIL: patient information leaflet; pMDI: pressurized metered-dose inhaler; SAL: salmeterol xinafoate.
Collapse
Affiliation(s)
- Omar Usmani
- National Heart and Lung Institute, Imperial College London & Royal Brompton Hospital, London, UK
| | - Nicolas Roche
- Cochin Hospital (APHP), University Paris Descartes, Paris, France
| | | | - Helen Danagher
- Mundipharma International Technical Operations, Cambridge, UK
| | - David Price
- Observational and Pragmatic Research Institute Pte Ltd, Singapore, Singapore.,Centre of Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Aberdeen, UK
| |
Collapse
|
8
|
K-haler® breath-triggered inhaler: a profile of the properties of the device. DRUGS & THERAPY PERSPECTIVES 2019. [DOI: 10.1007/s40267-019-00635-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
9
|
Forster R, Ratcliffe A, Lewis M, Crossley A, Bastida JL, Dunlop WCN. Cost-utility analysis of an intervention designed to reduce the critical handling error of insufficient inspiratory effort. THE EUROPEAN JOURNAL OF HEALTH ECONOMICS : HEPAC : HEALTH ECONOMICS IN PREVENTION AND CARE 2018; 19:1303-1318. [PMID: 29754324 DOI: 10.1007/s10198-018-0974-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Accepted: 04/03/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVES Up to 70-80% of patients use inhalers incorrectly. Dry-powder inhalers (DPIs) require forceful inhalation for optimal delivery, and approximately 40% of Global Initiative for Asthma (GINA)-defined Step-3+ patients inhale corticosteroid and long-acting beta-agonist through DPIs. The CRITIKAL study (Price et al. in J Allergy Clin Immunol Pract 5:1071-e9-1081-e9, 2017) found a statistically significant association between 'insufficient inspiratory effort' error and increased risk of uncontrolled asthma and hospitalisation-requiring exacerbations. This paper explores the cost-effectiveness of an error-targeted intervention. METHODS A probabilistic Markov cost-utility model simulated patients transitioning between controlled and uncontrolled health states over one year. Odds ratios (ORs, from the CRITIKAL study) of a patient having uncontrolled asthma conditional on making the error were applied to baseline transition probabilities sourced from the literature, both indirectly via an adjustment formula (Zhang et al. in JAMA 280:1690-1691, 1998) and directly by assuming OR approximates relative risk (RR). The analysis explored complete/partial eradication of the error when the intervention was priced to match comparators, as well as impact of indirect costs based on lost/reduced productivity. RESULTS The intervention dominated both DPI comparators over one year, with direct cost savings of £45/£86 with 0.0053/0.0102 additional quality-adjusted life years (QALYs), and had the highest probability of being cost-effective at a £20,000/QALY threshold. Key factors driving variance were weekly utilities per state and RR of moving to an uncontrolled state. CONCLUSION The analysis demonstrated the economic and societal costs of 'insufficient inspiratory effort' and potential economic benefits of introducing an effective intervention to reduce/eradicate this error. Further research should assess the economic impact of other handling errors.
Collapse
Affiliation(s)
- Rebecca Forster
- Mundipharma International Ltd, Cambridge Science Park, Cambridge, CB4 0AB, UK
| | - Aran Ratcliffe
- Adelphi Values Ltd, Adelphi Mill, Macclesfield, Cheshire, SK10 5JB, UK
| | - Megan Lewis
- Adelphi Values Ltd, Adelphi Mill, Macclesfield, Cheshire, SK10 5JB, UK
| | - Amy Crossley
- Adelphi Values Ltd, Adelphi Mill, Macclesfield, Cheshire, SK10 5JB, UK
| | | | - William C N Dunlop
- Mundipharma International Ltd, Cambridge Science Park, Cambridge, CB4 0AB, UK.
| |
Collapse
|
10
|
Kappeler D, Sommerer K, Kietzig C, Huber B, Woodward J, Lomax M, Dalvi P. Pulmonary deposition of fluticasone propionate/formoterol in healthy volunteers, asthmatics and COPD patients with a novel breath-triggered inhaler. Respir Med 2018; 138:107-114. [PMID: 29724381 DOI: 10.1016/j.rmed.2018.03.029] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 02/08/2018] [Accepted: 03/28/2018] [Indexed: 11/16/2022]
Abstract
INTRODUCTION A combination of fluticasone propionate/formoterol fumarate (FP/FORM) has been incorporated within a novel, breath-triggered device, named K-haler®. This low resistance device requires a gentle inspiratory effort to actuate it, triggering at an inspiratory flow rate of approximately 30 L/min; thus avoiding the need for coordination of inhalation with manual canister depression. The aim of the study was to evaluate total and regional pulmonary deposition of FP/FORM when administered via the K-haler device. MATERIALS AND METHODS Twelve healthy subjects, 12 asthmatics, and 12 COPD patients each received a single dose of 2 puffs 99mtechnetium-labelled FP/FORM 125/5 μg. A gamma camera was used to obtain anterior and posterior two-dimensional images of drug deposition. Prior transmission scans (using a99mtechnetium flood source) allowed the definition of regions of interest and calculation of attenuation correction factors. Image analysis was performed per standardised methods. RESULTS Of 36 subjects, 35 provided evaluable post-dose scintigraphic data. Mean subject ages were 35.7 (healthy), 44.5 (asthma) and 61.7 years (COPD); mean FEV1% predicted values were 109.8%, 77.4% and 43.2%, respectively. Mean pulmonary deposition was 26.6% (healthy), 44.7% (asthma), 39.0% (COPD) of the delivered dose. The respective mean penetration indices (peripheral:central ratio normalised to a transmission lung scan) were 0.44, 0.31 and 0.30. CONCLUSION FP/FORM administration via the K-haler device resulted in high lung deposition in patients with obstructive lung disease but somewhat lesser deposition in healthy subjects. Regional deposition data demonstrated drug deposition in both the central and peripheral regions in all subject populations. EUDRACT NUMBER 2015-000744-42.
Collapse
Affiliation(s)
| | - Knut Sommerer
- Inamed GmbH, Robert-Koch-Allee 29, Gauting, Germany.
| | | | - Bärbel Huber
- Inamed GmbH, Robert-Koch-Allee 29, Gauting, Germany.
| | - Jo Woodward
- Mundipharma Research Limited, Cambridge Science Park, Milton Road, Cambridge, CB4 0AB, UK.
| | - Mark Lomax
- Mundipharma Research Limited, Cambridge Science Park, Milton Road, Cambridge, CB4 0AB, UK.
| | - Prashant Dalvi
- Mundipharma Research Limited, Cambridge Science Park, Milton Road, Cambridge, CB4 0AB, UK.
| |
Collapse
|