1
|
Marei I, Abu Samaan T, Al-Quradaghi MA, Farah AA, Mahmud SH, Ding H, Triggle CR. 3D Tissue-Engineered Vascular Drug Screening Platforms: Promise and Considerations. Front Cardiovasc Med 2022; 9:847554. [PMID: 35310996 PMCID: PMC8931492 DOI: 10.3389/fcvm.2022.847554] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Accepted: 02/03/2022] [Indexed: 12/12/2022] Open
Abstract
Despite the efforts devoted to drug discovery and development, the number of new drug approvals have been decreasing. Specifically, cardiovascular developments have been showing amongst the lowest levels of approvals. In addition, concerns over the adverse effects of drugs to the cardiovascular system have been increasing and resulting in failure at the preclinical level as well as withdrawal of drugs post-marketing. Besides factors such as the increased cost of clinical trials and increases in the requirements and the complexity of the regulatory processes, there is also a gap between the currently existing pre-clinical screening methods and the clinical studies in humans. This gap is mainly caused by the lack of complexity in the currently used 2D cell culture-based screening systems, which do not accurately reflect human physiological conditions. Cell-based drug screening is widely accepted and extensively used and can provide an initial indication of the drugs' therapeutic efficacy and potential cytotoxicity. However, in vitro cell-based evaluation could in many instances provide contradictory findings to the in vivo testing in animal models and clinical trials. This drawback is related to the failure of these 2D cell culture systems to recapitulate the human physiological microenvironment in which the cells reside. In the body, cells reside within a complex physiological setting, where they interact with and respond to neighboring cells, extracellular matrix, mechanical stress, blood shear stress, and many other factors. These factors in sum affect the cellular response and the specific pathways that regulate variable vital functions such as proliferation, apoptosis, and differentiation. Although pre-clinical in vivo animal models provide this level of complexity, cross species differences can also cause contradictory results from that seen when the drug enters clinical trials. Thus, there is a need to better mimic human physiological conditions in pre-clinical studies to improve the efficiency of drug screening. A novel approach is to develop 3D tissue engineered miniaturized constructs in vitro that are based on human cells. In this review, we discuss the factors that should be considered to produce a successful vascular construct that is derived from human cells and is both reliable and reproducible.
Collapse
Affiliation(s)
- Isra Marei
- Department of Pharmacology, Weill Cornell Medicine-Qatar, Doha, Qatar
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- *Correspondence: Isra Marei
| | - Tala Abu Samaan
- Department of Pharmacology, Weill Cornell Medicine-Qatar, Doha, Qatar
| | | | - Asmaa A. Farah
- Department of Pharmacology, Weill Cornell Medicine-Qatar, Doha, Qatar
| | | | - Hong Ding
- Department of Pharmacology, Weill Cornell Medicine-Qatar, Doha, Qatar
| | - Chris R. Triggle
- Department of Pharmacology, Weill Cornell Medicine-Qatar, Doha, Qatar
- Chris R. Triggle
| |
Collapse
|
2
|
Huang AH, Balestrini JL, Udelsman BV, Zhou KC, Zhao L, Ferruzzi J, Starcher BC, Levene MJ, Humphrey JD, Niklason LE. Biaxial Stretch Improves Elastic Fiber Maturation, Collagen Arrangement, and Mechanical Properties in Engineered Arteries. Tissue Eng Part C Methods 2017; 22:524-33. [PMID: 27108525 DOI: 10.1089/ten.tec.2015.0309] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Tissue-engineered blood vessels (TEVs) are typically produced using the pulsatile, uniaxial circumferential stretch to mechanically condition and strengthen the arterial grafts. Despite improvements in the mechanical integrity of TEVs after uniaxial conditioning, these tissues fail to achieve critical properties of native arteries such as matrix content, collagen fiber orientation, and mechanical strength. As a result, uniaxially loaded TEVs can result in mechanical failure, thrombus, or stenosis on implantation. In planar tissue equivalents such as artificial skin, biaxial loading has been shown to improve matrix production and mechanical properties. To date however, multiaxial loading has not been examined as a means to improve mechanical and biochemical properties of TEVs during culture. Therefore, we developed a novel bioreactor that utilizes both circumferential and axial stretch that more closely simulates loading conditions in native arteries, and we examined the suture strength, matrix production, fiber orientation, and cell proliferation. After 3 months of biaxial loading, TEVs developed a formation of mature elastic fibers that consisted of elastin cores and microfibril sheaths. Furthermore, the distinctive features of collagen undulation and crimp in the biaxial TEVs were absent in both uniaxial and static TEVs. Relative to the uniaxially loaded TEVs, tissues that underwent biaxial loading remodeled and realigned collagen fibers toward a more physiologic, native-like organization. The biaxial TEVs also showed increased mechanical strength (suture retention load of 303 ± 14.53 g, with a wall thickness of 0.76 ± 0.028 mm) and increased compliance. The increase in compliance was due to combinatorial effects of mature elastic fibers, undulated collagen fibers, and collagen matrix orientation. In conclusion, biaxial stretching is a potential means to regenerate TEVs with improved matrix production, collagen organization, and mechanical properties.
Collapse
Affiliation(s)
- Angela H Huang
- 1 Department of Biomedical Engineering, School of Engineering and Applied Science, Yale University , New Haven, Connecticut
| | - Jenna L Balestrini
- 1 Department of Biomedical Engineering, School of Engineering and Applied Science, Yale University , New Haven, Connecticut
| | | | - Kevin C Zhou
- 1 Department of Biomedical Engineering, School of Engineering and Applied Science, Yale University , New Haven, Connecticut
| | - Liping Zhao
- 2 School of Medicine, Yale University , New Haven, Connecticut
| | - Jacopo Ferruzzi
- 1 Department of Biomedical Engineering, School of Engineering and Applied Science, Yale University , New Haven, Connecticut
| | - Barry C Starcher
- 3 Department of Biochemistry, The University of Texas Health Science Center at Tyler , Tyler, Texas
| | - Michael J Levene
- 1 Department of Biomedical Engineering, School of Engineering and Applied Science, Yale University , New Haven, Connecticut
| | - Jay D Humphrey
- 1 Department of Biomedical Engineering, School of Engineering and Applied Science, Yale University , New Haven, Connecticut
| | - Laura E Niklason
- 1 Department of Biomedical Engineering, School of Engineering and Applied Science, Yale University , New Haven, Connecticut.,2 School of Medicine, Yale University , New Haven, Connecticut
| |
Collapse
|
3
|
Wang R, Raykin J, Brewster LP, Gleason RL. A Novel Approach to Assess the In Situ Versus Ex Vivo Mechanical Behaviors of the Coronary Artery. J Biomech Eng 2017; 139:2588204. [PMID: 27893049 DOI: 10.1115/1.4035262] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2016] [Indexed: 11/08/2022]
Abstract
Ex vivo mechanical testing has provided tremendous insight toward prediction of the in vivo mechanical behavior and local mechanical environment of the arterial wall; however, the role of perivascular support on the local mechanical behavior of arteries is not well understood. Here, we present a novel approach for quantifying the impact of the perivascular support on arterial mechanics using intravascular ultrasound (IVUS) on cadaveric porcine hearts. We performed pressure-diameter tests (n = 5) on the left anterior descending coronary arteries (LADCAs) in situ while embedded in their native perivascular environment using IVUS imaging and after removal of the perivascular support of the artery. We then performed standard cylindrical biaxial testing on these vessels ex vivo and compared the results. Removal of the perivascular support resulted in an upward shift of the pressure-diameter curve. Ex vivo testing, however, showed significantly lower circumferential compliance compared to the in situ configuration. On a second set of arteries, local axial stretch ratios were quantified (n = 5) along the length of the arteries. The average in situ axial stretch ratio was 1.28 ± 0.16; however, local axial stretch ratios showed significant variability, ranging from 1.01 to 1.70. Taken together, the data suggest that both the perivascular loading and the axial tethering have an important role in arterial mechanics. Combining nondestructive testing using IVUS with traditional ex vivo cylindrical biaxial testing yields a more comprehensive assessment of the mechanical behavior of arteries.
Collapse
Affiliation(s)
- Ruoya Wang
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| | - Julia Raykin
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| | - Luke P Brewster
- Parker H. Petit Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Woodruff Memorial Research Building, 101 Woodruff Circle, Suite 5105, Atlanta, GA 30332;Department of Surgery, Emory University School of Medicine, Atlanta, GA 30307; Surgical and Research Services, Atlanta VA Medical Center, Atlanta, GA 30033 e-mail:
| | - Rudolph L Gleason
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332;Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332;Parker H. Petit Institute of Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Drive, IBB 2305, Atlanta, GA 30332 e-mail:
| |
Collapse
|
4
|
Hoenicka M, Kaspar M, Schmid C, Liebold A, Schrammel S. Contact-free monitoring of vessel graft stiffness - proof of concept as a tool for vascular tissue engineering. J Tissue Eng Regen Med 2016; 11:2828-2835. [PMID: 27257044 DOI: 10.1002/term.2186] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Revised: 03/04/2016] [Accepted: 03/14/2016] [Indexed: 01/03/2023]
Abstract
Tissue-engineered vessel grafts have to mimic the biomechanical properties of native blood vessels. Manufacturing processes often condition grafts to adapt them to the target flow conditions. Graft stiffness is influenced by material properties and dimensions and determines graft compliance. This proof-of-concept study evaluated a contact-free method to monitor biomechanical properties without compromising sterility. Forced vibration response analysis was performed on human umbilical vein (HUV) segments mounted in a buffer-filled tubing system. A linear motor and a dynamic signal analyser were used to excite the fluid by white noise (0-200 Hz). Vein responses were read out by laser triangulation and analysed by fast Fourier transformation. Modal analysis was performed by monitoring multiple positions of the vessel surface. As an inverse model of graft stiffening during conditioning, HUV were digested proteolytically, and the course of natural frequencies (NFs) was monitored over 120 min. Human umbilical vein showed up to five modes with NFs in the range of 5-100 Hz. The first natural frequencies of HUV did not alter over time while incubated in buffer (p = 0.555), whereas both collagenase (-35%, p = 0.0061) and elastase (-45%, p < 0.001) treatments caused significant decreases of NF within 120 min. Decellularized HUV showed similar results, indicating that changes of the extracellular matrix were responsible for the observed shift in NF. Performing vibration response analysis on vessel grafts is feasible without compromising sterility or integrity of the samples. This technique allows direct measurement of stiffness as an important biomechanical property, obviating the need to monitor surrogate parameters. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Markus Hoenicka
- Department of Cardiothoracic and Vascular Surgery, University of Ulm Medical Centre, Ulm, Germany.,Department of Cardiothoracic Surgery, University of Regensburg Medical Centre, Regensburg, Germany
| | - Marcel Kaspar
- Ostbayerische Technische Hochschule (OTH) Regensburg, FB Maschinenbau, Regensburg, Germany
| | - Christof Schmid
- Department of Cardiothoracic Surgery, University of Regensburg Medical Centre, Regensburg, Germany
| | - Andreas Liebold
- Department of Cardiothoracic and Vascular Surgery, University of Ulm Medical Centre, Ulm, Germany
| | - Siegfried Schrammel
- Ostbayerische Technische Hochschule (OTH) Regensburg, FB Maschinenbau, Regensburg, Germany
| |
Collapse
|
5
|
Characterization of the mechanical behavior of the optic nerve sheath and its role in spaceflight-induced ophthalmic changes. Biomech Model Mechanobiol 2016; 16:33-43. [PMID: 27236645 DOI: 10.1007/s10237-016-0800-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Accepted: 05/17/2016] [Indexed: 12/14/2022]
Abstract
Visual impairment and intracranial pressure (VIIP) syndrome is characterized by a number of permanent ophthalmic changes, including loss of visual function. It occurs in some astronauts during long-duration spaceflight missions. Thus, understanding the pathophysiology of VIIP is currently a major priority in space medicine research. It is hypothesized that maladaptive remodeling of the optic nerve sheath (ONS), in response to microgravity-induced elevations in intracranial pressure (ICP), contributes to VIIP. However, little is known about ONS biomechanics. In this study, we developed a custom mechanical testing system that allowed for unconfined lengthening, twisting, and circumferential distension of the porcine ONS during inflation and axial loading. Data were fit to a four-fiber family constitutive equation to extract material and structural parameters. Inflation testing showed a characteristic "cross-over point" in the pressure-diameter curves under different axial loads in all samples that were tested; the cross-over pressure was [Formula: see text] mmHg ([Formula: see text]). Large sample-to-sample variations were observed in the circumferential strain, while only modest variations were observed in the circumferential stress. Multiphoton microscopy revealed that the collagen fibers of the ONS were primarily oriented axially when the tissue was loaded. The existence of this cross-over behavior is expected to be neuroprotective, as it would avoid optic nerve compression during routine changes in gaze angle, so long as ICP was within the normal range. Including these observations into computational models of VIIP will help provide insight into the pathophysiology of VIIP and could help identify risk factors and potential interventions.
Collapse
|
6
|
Huang AH, Lee YU, Calle EA, Boyle M, Starcher BC, Humphrey JD, Niklason LE. Design and Use of a Novel Bioreactor for Regeneration of Biaxially Stretched Tissue-Engineered Vessels. Tissue Eng Part C Methods 2015; 21:841-51. [PMID: 25669988 DOI: 10.1089/ten.tec.2014.0287] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Conventional bioreactors are used to enhance extracellular matrix (ECM) production and mechanical strength of tissue-engineered vessels (TEVs) by applying circumferential strain, which is uniaxial stretching. However, the resulting TEVs still suffer from inadequate mechanical properties, where rupture strengths and compliance values are still very different from native arteries. The biomechanical milieu of native arteries consists of both circumferential and axial loading. Therefore, to better simulate the physiological stresses acting on native arteries, we built a novel bioreactor system to enable biaxial stretching of engineered arteries during culture. This new bioreactor system allows for independent control of circumferential and axial stretching parameters, such as displacement and beat rate. The assembly and setup processes for this biaxial bioreactor system are reliable with a success rate greater than 75% for completion of long-term sterile culture. This bioreactor also supports side-by-side assessments of TEVs that are cultured under three types of mechanical conditions (static, uniaxial, and biaxial), all within the same biochemical environment. Using this bioreactor, we examined the impact of biaxial stretching on arterial wall remodeling of TEVs. Biaxial TEVs developed the greatest wall thickness compared with static and uniaxial TEVs. Unlike uniaxial loading, biaxial loading led to undulated collagen fibers that are commonly found in native arteries. More importantly, the biaxial TEVs developed the most mature elastin in the ECM, both qualitatively and quantitatively. The presence of mature extracellular elastin along with the undulated collagen fibers may contribute to the observed vascular compliance in the biaxial TEVs. The current work shows that biaxial stretching is a novel and promising means to improve TEV generation. Furthermore, this novel system allows us to optimize biomechanical conditioning by unraveling the interrelationships among the applied mechanical stress, the resulting ECM properties, and the mechanics of TEVs.
Collapse
Affiliation(s)
- Angela Hai Huang
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Yong-Ung Lee
- 2 Tissue Engineering Program and Surgical Research, Nationwide Children's Hospital , Columbus, Ohio
| | - Elizabeth A Calle
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Michael Boyle
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Barry C Starcher
- 3 Department of Biochemistry, The University of Texas Health Science Center , Tyler, Texas
| | - Jay D Humphrey
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut
| | - Laura E Niklason
- 1 Department of Biomedical Engineering, Yale University , New Haven, Connecticut.,4 Department of Anesthesiology, Yale University , New Haven, Connecticut
| |
Collapse
|
7
|
Huang AH, Niklason LE. Engineering of arteries in vitro. Cell Mol Life Sci 2014; 71:2103-18. [PMID: 24399290 PMCID: PMC4024341 DOI: 10.1007/s00018-013-1546-3] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Revised: 12/17/2013] [Accepted: 12/18/2013] [Indexed: 12/20/2022]
Abstract
This review will focus on two elements that are essential for functional arterial regeneration in vitro: the mechanical environment and the bioreactors used for tissue growth. The importance of the mechanical environment to embryological development, vascular functionality, and vascular graft regeneration will be discussed. Bioreactors generate mechanical stimuli to simulate biomechanical environment of arterial system. This system has been used to reconstruct arterial grafts with appropriate mechanical strength for implantation by controlling the chemical and mechanical environments in which the grafts are grown. Bioreactors are powerful tools to study the effect of mechanical stimuli on extracellular matrix architecture and mechanical properties of engineered vessels. Hence, biomimetic systems enable us to optimize chemo-biomechanical culture conditions to regenerate engineered vessels with physiological properties similar to those of native arteries. In addition, this article reviews various bioreactors designed especially to apply axial loading to engineered arteries. This review will also introduce and examine different approaches and techniques that have been used to engineer biologically based vascular grafts, including collagen-based grafts, fibrin-gel grafts, cell sheet engineering, biodegradable polymers, and decellularization of native vessels.
Collapse
Affiliation(s)
- Angela H Huang
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA,
| | | |
Collapse
|
8
|
Wang R, Raykin J, Li H, Gleason RL, Brewster LP. Differential mechanical response and microstructural organization between non-human primate femoral and carotid arteries. Biomech Model Mechanobiol 2014; 13:1041-51. [PMID: 24532266 DOI: 10.1007/s10237-014-0553-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Accepted: 01/08/2014] [Indexed: 01/13/2023]
Abstract
Unique anatomic locations and physiologic functions predispose different arteries to varying mechanical responses and pathologies. However, the underlying causes of these mechanical differences are not well understood. The objective of this study was to first identify structural differences in the arterial matrix that would account for the mechanical differences between healthy femoral and carotid arteries and second to utilize these structural observations to perform a microstructurally motivated constitutive analysis. Femoral and carotid arteries were subjected to cylindrical biaxial loading and their microstructure was quantified using two-photon microscopy. The femoral arteries were found to be less compliant than the carotid arteries at physiologic loads, consistent with previous studies, despite similar extracellular compositions of collagen and elastin ([Formula: see text]). The femoral arteries exhibited significantly less circumferential dispersion of collagen fibers ([Formula: see text]), despite a similar mean fiber alignment direction as the carotid arteries. Elastin transmural distribution, in vivo axial stretch, and opening angles were also found to be distinctly different between the arteries. Lastly, we modeled the arteries' mechanical behaviors using a microstructural-based, distributed collagen fiber constitutive model. With this approach, the material parameters of the model were solved using the experimental microstructural observations. The findings of this study support an important role for microstructural organization in arterial stiffness.
Collapse
Affiliation(s)
- Ruoya Wang
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA,
| | | | | | | | | |
Collapse
|
9
|
Truskey GA, Achneck HE, Bursac N, Chan H, Cheng CS, Fernandez C, Hong S, Jung Y, Koves T, Kraus WE, Leong K, Madden L, Reichert WM, Zhao X. Design considerations for an integrated microphysiological muscle tissue for drug and tissue toxicity testing. Stem Cell Res Ther 2013; 4 Suppl 1:S10. [PMID: 24565225 PMCID: PMC4029361 DOI: 10.1186/scrt371] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Microphysiological systems provide a tool to simulate normal and pathological function of organs for prolonged periods. These systems must incorporate the key functions of the individual organs and enable interactions among the corresponding microphysiological units. The relative size of different microphysiological organs and their flow rates are scaled in proportion to in vivo values. We have developed a microphysiological three-dimensional engineered human skeletal muscle system connected to a circulatory system that consists of a tissue-engineered blood vessel as part of a high-pressure arterial system. The engineered human skeletal muscle tissue reproduces key mechanical behaviors of skeletal muscle in vivo. Pulsatile flow is produced using a novel computer-controlled magnetically activated ferrogel. The system is versatile and the muscle unit can be integrated with other organ systems. Periodic monitoring of biomechanical function provides a non-invasive assessment of the health of the tissue and a way to measure the response to drugs and toxins.
Collapse
|
10
|
Wang R, Brewster LP, Gleason RL. In-situ characterization of the uncrimping process of arterial collagen fibers using two-photon confocal microscopy and digital image correlation. J Biomech 2013; 46:2726-9. [PMID: 24050510 DOI: 10.1016/j.jbiomech.2013.08.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2013] [Revised: 08/10/2013] [Accepted: 08/12/2013] [Indexed: 11/24/2022]
Abstract
Uncrimping of collagen fibers in the arterial wall is an integral process in regulating the macro-level mechanical response of arteries. Uncrimping of collagen fibers leads to a gradual, but significant strain-stiffening response of the artery at physiological pressures and prevents overdistention at elevated pressures. In this study, we imaged adventitial collagen fibers from fresh primate arteries using two-photon excitation microscopy while subjecting the arteries to physiological inflation pressures and axial stretches. The imaging focal plane was fixed at a constant radial location in the adventitial wall by adjusting the focal distance as the arteries inflated, allowing for the continuously monitoring of the uncrimping process of a single region of collagen fibers. Digital image correlation was then applied to the sequential images to assess and correlate the local displacements to manual traces of selected reference fibers and their engagements. We found that the collagen fibers of interest became fully engaged at a luminal pressure of 20mmHg, this was then followed by rotation of these fibers as the bulk artery continued to dilate. This technique helps to further the understanding of the uncrimping process of collagen fibers under physiological loads, which can aid in the development of more accurate microstructural constitutive models.
Collapse
Affiliation(s)
- Ruoya Wang
- George W. Woodruff School of Mechanical Engineering, USA; Department of Surgery, Division of Vascular Surgery, Emory University School of Medicine, Atlanta, GA, USA.
| | | | | |
Collapse
|
11
|
Salehi-Nik N, Amoabediny G, Pouran B, Tabesh H, Shokrgozar MA, Haghighipour N, Khatibi N, Anisi F, Mottaghy K, Zandieh-Doulabi B. Engineering parameters in bioreactor's design: a critical aspect in tissue engineering. BIOMED RESEARCH INTERNATIONAL 2013; 2013:762132. [PMID: 24000327 PMCID: PMC3755438 DOI: 10.1155/2013/762132] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Revised: 06/27/2013] [Accepted: 07/01/2013] [Indexed: 12/21/2022]
Abstract
Bioreactors are important inevitable part of any tissue engineering (TE) strategy as they aid the construction of three-dimensional functional tissues. Since the ultimate aim of a bioreactor is to create a biological product, the engineering parameters, for example, internal and external mass transfer, fluid velocity, shear stress, electrical current distribution, and so forth, are worth to be thoroughly investigated. The effects of such engineering parameters on biological cultures have been addressed in only a few preceding studies. Furthermore, it would be highly inefficient to determine the optimal engineering parameters by trial and error method. A solution is provided by emerging modeling and computational tools and by analyzing oxygen, carbon dioxide, and nutrient and metabolism waste material transports, which can simulate and predict the experimental results. Discovering the optimal engineering parameters is crucial not only to reduce the cost and time of experiments, but also to enhance efficacy and functionality of the tissue construct. This review intends to provide an inclusive package of the engineering parameters together with their calculation procedure in addition to the modeling techniques in TE bioreactors.
Collapse
Affiliation(s)
- Nasim Salehi-Nik
- Department of Chemical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11365-4563, Tehran, Iran
- Department of Biomedical Engineering, Research Center for New Technologies in Life Science Engineering, University of Tehran, P.O. Box 14395-1374, Tehran, Iran
| | - Ghassem Amoabediny
- Department of Chemical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11365-4563, Tehran, Iran
- Department of Biomedical Engineering, Research Center for New Technologies in Life Science Engineering, University of Tehran, P.O. Box 14395-1374, Tehran, Iran
| | - Behdad Pouran
- Department of Chemical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11365-4563, Tehran, Iran
- Department of Biomedical Engineering, Research Center for New Technologies in Life Science Engineering, University of Tehran, P.O. Box 14395-1374, Tehran, Iran
| | - Hadi Tabesh
- Institute of Physiology, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | | | - Nooshin Haghighipour
- National Cell Bank, Pasteur Institute of Iran, P.O. Box 1316943551, Tehran, Iran
| | - Nahid Khatibi
- Department of Chemical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11365-4563, Tehran, Iran
- Department of Biomedical Engineering, Research Center for New Technologies in Life Science Engineering, University of Tehran, P.O. Box 14395-1374, Tehran, Iran
| | - Fatemeh Anisi
- Department of Chemical Engineering, Faculty of Engineering, University of Tehran, P.O. Box 11365-4563, Tehran, Iran
- Department of Biomedical Engineering, Research Center for New Technologies in Life Science Engineering, University of Tehran, P.O. Box 14395-1374, Tehran, Iran
| | - Khosrow Mottaghy
- Institute of Physiology, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | | |
Collapse
|
12
|
Blood Vessel Tissue Engineering. Biomater Sci 2013. [DOI: 10.1016/b978-0-08-087780-8.00115-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
13
|
Couet F, Mantovani D. Perspectives on the advanced control of bioreactors for functional vascular tissue engineering in vitro. Expert Rev Med Devices 2012; 9:233-9. [PMID: 22702253 DOI: 10.1586/erd.12.15] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Tissue engineering aims to produce tissues using cells and materials. The action of designing tissues involves observing the process of growth to understand its underlying mechanisms. It requires manipulation of the critical parameters for cell growth and remodeling to produce structured tissues and functional organs. Tissue engineers face the challenge of orchestrating the signals in a cell's microenvironment to efficiently grow an anisotropic and hierarchical tissue. It can be performed in vivo through the design of bioactive scaffolds and manipulation of biological signals using growth factors. It can also be performed in vitro in a controlled environment called the bioreactor. This article addresses the matter of finding the optimal dynamic sequence of culture conditions in a bioreactor for the maturation of tissues. Artificial intelligence and optimal control are accelerating technologies towards an understanding of tissue regeneration. The particular example of the functional engineering of small-diameter blood vessels has been chosen to illustrate this idea.
Collapse
Affiliation(s)
- Frédéric Couet
- Laboratory for Biomaterials and Bioengineering, Department of Min-Met-Materials Engineering and University Hospital Research Center, Laval University, Québec City, QC, G1V 0A6, Canada
| | | |
Collapse
|
14
|
König F, Hollweck T, Pfeifer S, Reichart B, Wintermantel E, Hagl C, Akra B. A Pulsatile Bioreactor for Conditioning of Tissue-Engineered Cardiovascular Constructs under Endoscopic Visualization. J Funct Biomater 2012; 3:480-96. [PMID: 24955628 PMCID: PMC4031004 DOI: 10.3390/jfb3030480] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 06/27/2012] [Accepted: 07/09/2012] [Indexed: 12/28/2022] Open
Abstract
Heart valve disease (HVD) is a globally increasing problem and accounts for thousands of deaths yearly. Currently end-stage HVD can only be treated by total valve replacement, however with major drawbacks. To overcome the limitations of conventional substitutes, a new clinical approach based on cell colonization of artificially manufactured heart valves has been developed. Even though this attempt seems promising, a confluent and stable cell layer has not yet been achieved due to the high stresses present in this area of the human heart. This study describes a bioreactor with a new approach to cell conditioning of tissue engineered heart valves. The bioreactor provides a low pulsatile flow that grants the correct opening and closing of the valve without high shear stresses. The flow rate can be regulated allowing a steady and sensitive conditioning process. Furthermore, the correct functioning of the valve can be monitored by endoscope surveillance in real-time. The tubeless and modular design allows an accurate, simple and faultless assembly of the reactor in a laminar flow chamber. It can be concluded that the bioreactor provides a strong tool for dynamic pre-conditioning and monitoring of colonized heart valve prostheses physiologically exposed to shear stress.
Collapse
Affiliation(s)
- Fabian König
- Chair of Medical Engineering, Technical University Munich, Boltzmannstrasse 15, Garching 85748, Germany.
| | - Trixi Hollweck
- Department of Cardiac Surgery, Medical Center Munich University, Marchioninistr. 15, Munich 81377, Germany.
| | - Stefan Pfeifer
- Chair of Medical Engineering, Technical University Munich, Boltzmannstrasse 15, Garching 85748, Germany.
| | - Bruno Reichart
- Department of Cardiac Surgery, Medical Center Munich University, Marchioninistr. 15, Munich 81377, Germany.
| | - Erich Wintermantel
- Chair of Medical Engineering, Technical University Munich, Boltzmannstrasse 15, Garching 85748, Germany.
| | - Christian Hagl
- Department of Cardiac Surgery, Medical Center Munich University, Marchioninistr. 15, Munich 81377, Germany.
| | - Bassil Akra
- Department of Cardiac Surgery, Medical Center Munich University, Marchioninistr. 15, Munich 81377, Germany.
| |
Collapse
|
15
|
Gould RA, Chin K, Santisakultarm TP, Dropkin A, Richards JM, Schaffer CB, Butcher JT. Cyclic strain anisotropy regulates valvular interstitial cell phenotype and tissue remodeling in three-dimensional culture. Acta Biomater 2012; 8:1710-9. [PMID: 22281945 DOI: 10.1016/j.actbio.2012.01.006] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2011] [Revised: 12/20/2011] [Accepted: 01/05/2012] [Indexed: 01/05/2023]
Abstract
Many planar connective tissues exhibit complex anisotropic matrix fiber arrangements that are critical to their biomechanical function. This organized structure is created and modified by resident fibroblasts in response to mechanical forces in their environment. The directionality of applied strain fields changes dramatically during development, aging, and disease, but the specific effect of strain direction on matrix remodeling is less clear. Current mechanobiological inquiry of planar tissues is limited to equibiaxial or uniaxial stretch, which inadequately simulates many in vivo environments. In this study, we implement a novel bioreactor system to demonstrate the unique effect of controlled anisotropic strain on fibroblast behavior in three-dimensional (3-D) engineered tissue environments, using aortic valve interstitial fibroblast cells as a model system. Cell seeded 3-D collagen hydrogels were subjected to cyclic anisotropic strain profiles maintained at constant areal strain magnitude for up to 96 h at 1 Hz. Increasing anisotropy of biaxial strain resulted in increased cellular orientation and collagen fiber alignment along the principal directions of strain and cell orientation was found to precede fiber reorganization. Cellular proliferation and apoptosis were both significantly enhanced under increasing biaxial strain anisotropy (P<0.05). While cyclic strain reduced both vimentin and alpha-smooth muscle actin compared to unstrained controls, vimentin and alpha-smooth muscle actin expression increased with strain anisotropy and correlated with direction (P<0.05). Collectively, these results suggest that strain field anisotropy is an independent regulator of fibroblast cell phenotype, turnover, and matrix reorganization, which may inform normal and pathological remodeling in soft tissues.
Collapse
Affiliation(s)
- Russell A Gould
- Department of Biomedical Engineering, Cornell University, Ithaca, NY 14850, USA
| | | | | | | | | | | | | |
Collapse
|
16
|
Haskett D, Speicher E, Fouts M, Larson D, Azhar M, Utzinger U, Vande Geest J. The effects of angiotensin II on the coupled microstructural and biomechanical response of C57BL/6 mouse aorta. J Biomech 2011; 45:772-9. [PMID: 22196971 DOI: 10.1016/j.jbiomech.2011.11.017] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
RATIONALE Abdominal aortic aneurysm (AAA) is a complex disease that leads to a localized dilation of the infrarenal aorta, the rupture of which is associated with significant morbidity and mortality. Animal models of AAA can be used to study how changes in the microstructural and biomechanical behavior of aortic tissues develop as disease progresses in these animals. We chose here to investigate the effect of angiotensin II (AngII) in C57BL/6 mice as a first step towards understanding how such changes occur in the established ApoE(-/-) AngII infused mouse model of AAA. OBJECTIVE The objective of this study was to utilize a recently developed device in our laboratory to determine how the microstructural and biomechanical properties of AngII-infused C57BL/6 wildtype mouse aorta change following 14 days of AngII infusion. METHODS C57BL/6 wildtype mice were infused with either saline or AngII for 14 day. Aortas were excised and tested using a device capable of simultaneously characterizing the biaxial mechanical response and load-dependent (unfixed, unfrozen) extracellular matrix organization of mouse aorta (using multiphoton microscopy). Peak strains and stiffness values were compared across experimental groups, and both datasets were fit to a Fung-type constitutive model. The mean mode and full width at half maximum (FWHM) of fiber histograms from two photon microscopy were quantified in order to assess the preferred fiber distribution and degree of fiber splay, respectively. RESULTS The axial stiffness of all mouse aorta was found to be an order of magnitude larger than the circumferential stiffness. The aortic diameter was found to be significantly increased for the AngII infused mice as compared to saline infused control (p=0.026). Aneurysm, defined as a percent increase in maximum diameter of 30% (defined with respect to saline control), was found in 3 of the 6 AngII infused mice. These three mice displayed adventitial collagen that lacked characteristic fiber crimp. The biomechanical response in the AngII infused mice showed significantly reduced circumferential compliance. We also noticed that the ability of the adventitial collagen fibers in AngII infused mice to disperse in reaction to circumferential loading was suppressed. CONCLUSIONS Collagen remodeling is present following 14 days of AngII infusion in C57BL/6 mice. Aneurysmal development occurred in 50% of our AngII infused mice, and these dilatations were accompanied with adventitial collagen remodeling and decreased circumferential compliance.
Collapse
Affiliation(s)
- Darren Haskett
- Graduate Interdisciplinary Program of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721-0119, USA
| | | | | | | | | | | | | |
Collapse
|
17
|
Couet F, Meghezi S, Mantovani D. Fetal development, mechanobiology and optimal control processes can improve vascular tissue regeneration in bioreactors: an integrative review. Med Eng Phys 2011; 34:269-78. [PMID: 22133487 DOI: 10.1016/j.medengphy.2011.10.009] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2011] [Revised: 10/20/2011] [Accepted: 10/21/2011] [Indexed: 11/30/2022]
Abstract
Vascular tissue engineering aims to regenerate blood vessels to replace diseased arteries for cardiovascular patients. With the scaffold-based approach, cells are seeded on a scaffold showing specific properties and are expected to proliferate and self-organize into a functional vascular tissue. Bioreactors can significantly contribute to this objective by providing a suitable environment for the maturation of the tissue engineered blood vessel. It is recognized from the mechanotransduction principles that mechanical stimuli can influence the protein synthesis of the extra-cellular matrix thus leading to maturation and organization of the tissues. Up to date, no bioreactor is especially conceived to take advantage of the mechanobiology and optimize the construct maturation through an advanced control strategy. In this review, experimental strategies in the field of vascular tissue engineering are detailed, and a new approach inspired by fetal development, mechanobiology and optimal control paradigms is proposed. In this new approach, the culture conditions (i.e. flow, circumferential strain, pressure frequency, and others) are supposed to dynamically evolve to match the maturity of vascular constructs and maximize the efficiency of the regeneration process. Moreover, this approach allows the investigation of the mechanisms of growth, remodeling and mechanotransduction during the culture.
Collapse
Affiliation(s)
- Frédéric Couet
- Department of Materials Engineering & Research Centre, Quebec University Hospital, Laval University, Quebec City, Canada
| | | | | |
Collapse
|
18
|
Dynamic mechanical stimulations induce anisotropy and improve the tensile properties of engineered tissues produced without exogenous scaffolding. Acta Biomater 2011; 7:3294-301. [PMID: 21669302 DOI: 10.1016/j.actbio.2011.05.034] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2011] [Revised: 05/10/2011] [Accepted: 05/25/2011] [Indexed: 01/09/2023]
Abstract
Mechanical strength and the production of extracellular matrix (ECM) are essential characteristics for engineered tissues designed to repair and replace connective tissues that are subject to stress and strain. In this study, dynamic mechanical stimulation (DMS) was investigated as a method to improve the mechanical properties of engineered tissues produced without the use of an exogenous scaffold, referred to as the self-assembly approach. This method, based exclusively on the use of human cells without any exogenous scaffolding, allows for the production of a tissue sheet comprised of cells and ECM components synthesized by dermal fibroblasts in vitro. A bioreactor chamber was designed to apply cyclic strain to engineered tissues in order to determine if dynamic culture had an impact on their mechanical properties and ECM organization. Fibroblasts were cultured in the presence of ascorbic acid for 35 days to promote ECM production and allow the formation of a tissue sheet. This sheet was grown on a custom-built anchoring system allowing for easy manipulation and fixation of the tissue in the bioreactor. Following the 35 day period, tissues were maintained for 3 days in static culture (SC), or subjected either to a static mechanical stimulation of 10% strain, or a dynamic DMS with a duty cycle of 10% uniaxial cyclic strain at 1Hz. ECM was characterized by histology, immunofluorescence labeling and Western blotting. Both static and dynamic mechanical stimulation induced the alignment of assessed cytoskeletal proteins and ECM components parallel to the axis of applied strain and increased the ECM content of the tissues compared to SC. Measurement of the tensile mechanical properties revealed that mechanical stimulation significantly increases both the ultimate tensile strength and tensile modulus of the engineered tissues when compared to the non-stimulated control. Moreover, we demonstrated that cyclic strain significantly increases these parameters when compared to a static-loading stimulation and that mechanical stimulation contributes to the establishment of anisotropy in the structural and mechanical properties of self-assembled tissue sheets.
Collapse
|
19
|
Abstract
The recent advances in our understanding of lymphatic physiology and the role of the lymphatics in actively regulating fluid balance, lipid transport, and immune cell trafficking has been furthered in part through innovations in imaging, tissue engineering, quantitative biology, biomechanics, and computational modeling. Interdisciplinary and bioengineering approaches will continue to be crucial to the progression of the field, given that lymphatic biology and function are intimately woven with the local microenvironment and mechanical loads experienced by the vessel. This is particularly the case in lymphatic diseases such as lymphedema where the microenvironment can be drastically altered by tissue fibrosis and adipocyte accumulation. In this review we will highlight contributions engineering and mechanics have made to lymphatic physiology and will discuss areas that will be important for future research.
Collapse
|
20
|
Tissue Engineering of Blood Vessels: Functional Requirements, Progress, and Future Challenges. Cardiovasc Eng Technol 2011. [PMID: 23181145 DOI: 10.1007/s13239-011-0049-3] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Vascular disease results in the decreased utility and decreased availability of autologus vascular tissue for small diameter (< 6 mm) vessel replacements. While synthetic polymer alternatives to date have failed to meet the performance of autogenous conduits, tissue-engineered replacement vessels represent an ideal solution to this clinical problem. Ongoing progress requires combined approaches from biomaterials science, cell biology, and translational medicine to develop feasible solutions with the requisite mechanical support, a non-fouling surface for blood flow, and tissue regeneration. Over the past two decades interest in blood vessel tissue engineering has soared on a global scale, resulting in the first clinical implants of multiple technologies, steady progress with several other systems, and critical lessons-learned. This review will highlight the current inadequacies of autologus and synthetic grafts, the engineering requirements for implantation of tissue-engineered grafts, and the current status of tissue-engineered blood vessel research.
Collapse
|
21
|
Gauvin R, Guillemette M, Galbraith T, Bourget JM, Larouche D, Marcoux H, Aubé D, Hayward C, Auger FA, Germain L. Mechanical properties of tissue-engineered vascular constructs produced using arterial or venous cells. Tissue Eng Part A 2011; 17:2049-59. [PMID: 21457095 DOI: 10.1089/ten.tea.2010.0613] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
There is a clinical need for better blood vessel substitutes, as current surgical procedures are limited by the availability of suitable autologous vessels and suboptimal behavior of synthetic grafts in small caliber arterial graft (<5 mm) applications. The aim of the present study was to compare the mechanical properties of arterial and venous tissue-engineered vascular constructs produced by the self-assembly approach using cells extracted from either the artery or vein harvested from the same human umbilical cord. The production of a vascular construct comprised of a media and an adventitia (TEVMA) was achieved by rolling a continuous tissue sheet containing both smooth muscle cells and adventitial fibroblasts grown contiguously in the same tissue culture plate. Histology and immunofluorescence staining were used to evaluate the structure and composition of the extracellular matrix of the vascular constructs. The mechanical strength was assessed by uniaxial tensile testing, whereas viscoelastic behavior was evaluated by stepwise stress-relaxation and by cyclic loading hysteresis analysis. Tensile testing showed that the use of arterial cells resulted in stronger and stiffer constructs when compared with those produced using venous cells. Moreover, cyclic loading demonstrated that constructs produced using arterial cells were able to bear higher loads for the same amount of strain when compared with venous constructs. These results indicate that cells isolated from umbilical cord can be used to produce vascular constructs. Arterial constructs possessed superior mechanical properties when compared with venous constructs produced using cells isolated from the same human donor. This study highlights the fact that smooth muscle cells and fibroblasts originating from different cell sources can potentially lead to distinct tissue properties when used in tissue engineering applications.
Collapse
Affiliation(s)
- Robert Gauvin
- Centre LOEX de l'Université Laval, Génie tissulaire et régénérationand Département de Chirurgie, Faculté de Médecine, Université Laval Québec, Québec, Canada
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
A Computer-Controlled Apparatus for the Characterization of Mechanical and Viscoelastic Properties of Tissue-Engineered Vascular Constructs. Cardiovasc Eng Technol 2011. [DOI: 10.1007/s13239-011-0033-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
23
|
Zaucha MT, Gauvin R, Auger FA, Germain L, Gleason RL. Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels. J R Soc Interface 2010; 8:244-56. [PMID: 20554564 DOI: 10.1098/rsif.2010.0228] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Along with insights into the potential for graft success, knowledge of biomechanical properties of small diameter tissue-engineered blood vessel (TEBV) will enable designers to tailor the vessels' mechanical response to closer resemble that of native tissue. Composed of two layers that closely mimic the native media and adventitia, a tissue-engineered vascular adventitia (TEVA) is wrapped around a tissue-engineered vascular media (TEVM) to produce a self-assembled tissue-engineered media/adventia (TEVMA). The current study was undertaken to characterize the biaxial biomechanical properties of TEVM, TEVA and TEVMA under physiological pressures as well as characterize the stress-free reference configuration. It was shown that the TEVA had the greatest compliance over the physiological loading range while the TEVM had the lowest compliance. As expected, compliance of the SA-TEBV fell in between with an average compliance of 2.73 MPa(-1). Data were used to identify material parameters for a microstructurally motivated constitutive model. Identified material parameters for the TEVA and TEVM provided a good fit to experimental data with an average coefficient of determination of 0.918 and 0.868, respectively. These material parameters were used to develop a two-layer predictive model for the response of a TEVMA which fit well with experimental data.
Collapse
Affiliation(s)
- Michael T Zaucha
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, , 801 Ferst Drive, Atlanta, GA 30332-0405, USA
| | | | | | | | | |
Collapse
|
24
|
Wang R, Gleason RL. A mechanical analysis of conduit arteries accounting for longitudinal residual strains. Ann Biomed Eng 2010; 38:1377-87. [PMID: 20087772 DOI: 10.1007/s10439-010-9916-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2009] [Accepted: 01/05/2010] [Indexed: 10/19/2022]
Abstract
Identification of an appropriate stress-free reference configuration is critically important in providing a reasonable prediction of the intramural stress distribution when performing biomechanical analyses on arteries. The stress-free state is commonly approximated as a radially cut ring that typically opens into a nearly circular sector, relieving much of the circumferential residual strains that exist in the traction-free configuration. An opening angle is often used to characterize this sector. In this study, we first present experimental results showing significant residual deformations in the longitudinal direction of two commonly studied arteries in the pig: the common carotid artery and the left anterior descending coronary artery. We concluded that a radially cut ring cannot completely describe the stress-free state of the arteries. Instead, we propose the use of a longitudinal opening angle, in conjunction with the traditional circumferential opening angle, to experimentally quantify the stress-free state of an artery. Secondly, we propose a new kinematic model to account for the addition of longitudinal residual strains through employing the longitudinal opening angle and performed a stress analysis. We found that with the inclusion of longitudinal residual strains in the stress analysis, the predicted circumferential stress gradient was decreased by 3-fold and the predicted longitudinal stress gradient was increased by 5.7-fold. Thus, inclusion of longitudinal residual strains has a significant effect on the predicted stress distribution in arteries.
Collapse
Affiliation(s)
- Ruoya Wang
- George W Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332, USA
| | | |
Collapse
|
25
|
Raykin J, Rachev AI, Gleason RL. A phenomenological model for mechanically mediated growth, remodeling, damage, and plasticity of gel-derived tissue engineered blood vessels. J Biomech Eng 2010; 131:101016. [PMID: 19831486 DOI: 10.1115/1.4000124] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Mechanical stimulation has been shown to dramatically improve mechanical and functional properties of gel-derived tissue engineered blood vessels (TEBVs). Adjusting factors such as cell source, type of extracellular matrix, cross-linking, magnitude, frequency, and time course of mechanical stimuli (among many other factors) make interpretation of experimental results challenging. Interpretation of data from such multifactor experiments requires modeling. We present a modeling framework and simulations for mechanically mediated growth, remodeling, plasticity, and damage of gel-derived TEBVs that merge ideas from classical plasticity, volumetric growth, and continuum damage mechanics. Our results are compared with published data and suggest that this model framework can predict the evolution of geometry and material behavior under common experimental loading scenarios.
Collapse
Affiliation(s)
- Julia Raykin
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, 30332, USA
| | | | | |
Collapse
|