1
|
Nilasaroya A, Kop AM, Collier RC, Kennedy B, Kelsey LJ, Pollard F, Ha JF, Morrison DA. Establishing local manufacture of PPE for healthcare workers in the time of a global pandemic. Heliyon 2023; 9:e13349. [PMID: 36816240 PMCID: PMC9922675 DOI: 10.1016/j.heliyon.2023.e13349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 01/10/2023] [Accepted: 01/25/2023] [Indexed: 02/16/2023] Open
Abstract
A face shield is a secondary personal protective equipment (PPE) for healthcare workers (HCW). Worn with the appropriate face masks/respirators, it provides short term barrier protection against potentially infectious droplet particles. Coronavirus disease 2019 (COVID-19) caused a spike in demand for PPE, leading to a shortage and risking the safety of HCW. Transport restrictions further challenged the existing PPE supply chain which has been reliant on overseas-based manufacturers. Despite the urgency in demand, PPE must be properly tested for functionality and quality. We describe the establishment of local face shields manufacture in Western Australia to ensure adequate PPE for HCW. Ten thousand face shields for general use (standard) and for ear, nose and throat (ENT) specialist use were produced. Materials and design considerations are described, and the face shields were vigorously tested to the relevant Standards to ensure their effectiveness as a protective barrier, including splash and impact resistance. Comparative testing with traditional and other novel face shields was also undertaken. Therapeutic Goods Administration (TGA) licence was obtained to manufacture and supply the face shields as a Class I medical device. The swiftness of process is a credit to collaboration from industry, academia and healthcare.
Collapse
Affiliation(s)
- Anastasia Nilasaroya
- Centre for Implant Technology and Retrievals Analysis (CITRA), Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Western Australia, 6000, Australia
| | - Alan Matthew Kop
- Centre for Implant Technology and Retrievals Analysis (CITRA), Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Western Australia, 6000, Australia
| | - Ryan Christopher Collier
- Centre for Implant Technology and Retrievals Analysis (CITRA), Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Western Australia, 6000, Australia
| | - Brendan Kennedy
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Western Australia, 6009, Australia and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, 6009, Australia,Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia, 6009, Australia,Australian Research Council Centre for Personalised Therapeutics Technologies, Australia
| | - Lachlan James Kelsey
- Vascular Engineering Laboratory, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, 6009, Australia,Department of Mechanical Engineering, School of Engineering, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia, 6009, Australia
| | - Faz Pollard
- Adarsh Australia, 6 Crocker Drive, Malaga, Western Australia, 6090, Australia
| | - Jennifer Fong Ha
- Department of Paediatrics Otolaryngology Head & Neck Surgery, Perth Children's Hospital, 15 Hospital Avenue, Nedlands, Western Australia, 6009, Australia,Murdoch ENT, Wexford Medical Centre, Suite 17-18, Level 1, 3 Barry Marshall Parade, Murdoch, Western Australia, 6150, Australia,Department of Surgery, The University of Western Australia, Stirling Highway, Nedlands, Western Australia, 6009, Australia
| | - David Anthony Morrison
- Centre for Implant Technology and Retrievals Analysis (CITRA), Department of Medical Engineering and Physics, Royal Perth Hospital, Perth, Western Australia, 6000, Australia,Corresponding author.
| |
Collapse
|
2
|
Brainard J, Hall S, van der Es M, Sekoni A, Price A, Padoveze MC, Ogunsola FT, Nichiata LYI, Hornsey E, Crook B, Cirino F, Chu L, Hunter PR. A mixed methods study on effectiveness and appropriateness of face shield use as COVID-19 PPE in middle income countries. Am J Infect Control 2022; 50:878-884. [PMID: 35908826 PMCID: PMC9329084 DOI: 10.1016/j.ajic.2022.01.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 01/24/2022] [Accepted: 01/24/2022] [Indexed: 11/29/2022]
Abstract
Background Face shields were widely used in 2020-2021 as facial personal protective equipment (PPE). Laboratory evidence about how protective face shields might be and whether real world user priorities and usage habits conflicted with best practice for maximum possible protection was lacking – especially in limited resource settings. Methods Relative protective potential of 13 face shield designs were tested in a controlled laboratory setting. Community and health care workers were surveyed in middle income country cities (Brazil and Nigeria) about their preferences and perspectives on face shields as facial PPE. Priorities about facial PPE held by survey participants were compared with the implications of the laboratory-generated test results. Results No face shield tested totally eliminated exposure. Head orientation and design features influenced the level of protection. Over 600 individuals were interviewed in Brazil and Nigeria (including 240 health care workers) in March-April 2021. Respondents commented on what influenced their preferred forms of facial PPE, how they tended to clean face shields, and their priorities in choosing a face cover product. Surveyed health care workers commonly bought personal protection equipment for use at work. Conclusions All face shields provided some protection but none gave high levels of protection against external droplet contamination. Respondents wanted facial PPE that considered good communication, secure fixture, good visibility, comfort, fashion, and has validated protectiveness.
Collapse
Affiliation(s)
- Julii Brainard
- Norwich Medical School, University of East Anglia, Norwich, Norfolk, UK.
| | - Samantha Hall
- UK Health and Safety Executive, Harpur Hill, Buxton, Derbyshire, UK
| | - Mike van der Es
- Norwich Medical School, University of East Anglia, Norwich, Norfolk, UK
| | - Adekemi Sekoni
- College of Medicine, University of Lagos, Lagos, Nigeria
| | - Amy Price
- Stanford University School of Medicine, Stanford, CA
| | | | | | | | - Emilio Hornsey
- UK Public Health Rapid Support Team, UK Health Security Agency, and London School of Hygiene & Tropical Medicine, London, UK
| | - Brian Crook
- UK Health and Safety Executive, Harpur Hill, Buxton, Derbyshire, UK
| | - Ferla Cirino
- Diadema Municipal Health Department, Diadema, São Paulo, Brazil
| | - Larry Chu
- Stanford University School of Medicine, Stanford, CA
| | - Paul R Hunter
- Norwich Medical School, University of East Anglia, Norwich, Norfolk, UK
| |
Collapse
|
3
|
Hall S, Johnson P, Bailey C, Gould Z, White R, Crook B. Evaluation of Face Shields, Goggles, and Safety Glasses as a Virus Transmission Control Measure to Protect the Wearer Against Cough Droplets. Ann Work Expo Health 2022; 67:36-49. [PMID: 35853621 PMCID: PMC9384474 DOI: 10.1093/annweh/wxac047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 04/08/2022] [Accepted: 06/23/2022] [Indexed: 01/14/2023] Open
Abstract
Face shields (also referred to as visors), goggles and safety glasses have been worn during the COVID-19 pandemic as one measure to control transmission of the virus. However, their effectiveness in controlling facial exposure to cough droplets is not well established and standard tests for evaluating eye protection for this application are limited. A method was developed to evaluate face shields, goggles, and safety glasses as a control measure to protect the wearer against cough droplets. The method uses a semi-quantitative assessment of facial droplet deposition. A cough simulator was developed to generate droplets comparable to those from a human cough. The droplets consisted of a UV fluorescent marker (fluorescein) in water. Fourteen face shields, four pairs of goggles and one pair of safety glasses were evaluated by mounting them on two different sizes of breathing manikin head and challenging them with the simulated cough. The manikin head was positioned in seven orientations relative to the cough simulator to represent various potential occupational exposure scenarios, for example, a nurse standing over a patient. Droplet deposition in the eyes, nose and mouth regions were visualised following three 'coughs'. Face shields, goggles, and safety glasses reduced, but did not eliminate exposure to the wearer from droplets such as those produced by a human cough. The level of protection differed based on the design of the personal protective equipment and the relative orientation of the wearer to the cough. For example, face shields, and goggles offered the greatest protection when a cough challenge was face on or from above and the least protection when a cough challenge was from below. Face shields were also evaluated as source control to protect others from the wearer. Results suggested that if a coughing person wears a face shield, it can provide some protection from cough droplets to those standing directly in front of the wearer.
Collapse
Affiliation(s)
- Samantha Hall
- Author to whom correspondence should be addressed. Tel: +44-02030282185; e-mail:
| | - Paul Johnson
- Health and Safety Executive Science and Research Centre, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK
| | - Claire Bailey
- Health and Safety Executive Science and Research Centre, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK
| | - Zoe Gould
- Health and Safety Executive Science and Research Centre, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK
| | - Robert White
- Health and Safety Executive Science and Research Centre, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK
| | - Brian Crook
- Health and Safety Executive Science and Research Centre, Harpur Hill, Buxton, Derbyshire SK17 9JN, UK
| |
Collapse
|
4
|
Issa N, Liddy WE, Samant S, Conley DB, Kern RC, Hungness ES, Cohen ER, Barsuk JH. Effectiveness of a simulation-based mastery learning to train clinicians on a novel cricothyrotomy procedure at an academic medical centre during a pandemic: a quasi-experimental cohort study. BMJ Open 2021; 11:e054746. [PMID: 34799364 PMCID: PMC8606759 DOI: 10.1136/bmjopen-2021-054746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVES To develop and evaluate a simulation-based mastery learning (SBML) curriculum for cricothyrotomy using wet towels to suppress aerosolisation during a pandemic. DESIGN Quasi-experimental, pre-post study. SETTING Tertiary care, academic medical centre in Chicago. PARTICIPANTS Ear, nose and throat and general surgery residents, fellows and attendings. INTERVENTION Cricothyroidotomy simulation-based mastery learning curriculum. OUTCOMES MEASURE Pretest to posttest simulated cricothyrotomy skills checklist performance. RESULTS 37 of 41 eligible surgeons participated in the curriculum. Median pretest score was 72.5 (IQR 55.0-80.0) and 100.0 (IQR 98.8-100.0) for the posttest p<0.001. All participants scored at or above a minimum passing standard (93% checklist items correct) at posttest. CONCLUSIONS Using SBML is effective to quickly train clinicians to competently perform simulated cricothyrotomy during a pandemic.
Collapse
Affiliation(s)
- Nabil Issa
- Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Whitney E Liddy
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Sandeep Samant
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - David B Conley
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Robert C Kern
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Eric S Hungness
- Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Elaine R Cohen
- Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Jeffrey H Barsuk
- Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| |
Collapse
|
5
|
Wilson J, Carson G, Fitzgerald S, Llewelyn MJ, Jenkins D, Parker S, Boies A, Thomas J, Sutcliffe K, Sowden AJ, O'Mara-Eves A, Stansfield C, Harriss E, Reilly J. Are medical procedures that induce coughing or involve respiratory suctioning associated with increased generation of aerosols and risk of SARS-CoV-2 infection? A rapid systematic review. J Hosp Infect 2021; 116:37-46. [PMID: 34245806 PMCID: PMC8264274 DOI: 10.1016/j.jhin.2021.06.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 06/28/2021] [Accepted: 06/30/2021] [Indexed: 12/14/2022]
Abstract
BACKGROUND The risk of transmission of SARS-CoV-2 from aerosols generated by medical procedures is a cause for concern. AIM To evaluate the evidence for aerosol production and transmission of respiratory infection associated with procedures that involve airway suctioning or induce coughing/sneezing. METHODS The review was informed by PRISMA guidelines. Searches were conducted in PubMed for studies published between January 1st, 2003 and October 6th, 2020. Included studies examined whether nasogastric tube insertion, lung function tests, nasendoscopy, dysphagia assessment, or suctioning for airway clearance result in aerosol generation or transmission of SARS-CoV-2, SARS-CoV, MERS, or influenza. Risk of bias assessment focused on robustness of measurement, control for confounding, and applicability to clinical practice. FINDINGS Eighteen primary studies and two systematic reviews were included. Three epidemiological studies found no association between nasogastric tube insertion and acquisition of respiratory infections. One simulation study found low/very low production of aerosols associated with pulmonary lung function tests. Seven simulation studies of endoscopic sinus surgery suggested significant increases in aerosols but findings were inconsistent; two clinical studies found airborne particles associated with the use of microdebriders/drills. Some simulation studies did not use robust measures to detect particles and are difficult to equate to clinical conditions. CONCLUSION There was an absence of evidence to suggest that the procedures included in the review were associated with an increased risk of transmission of respiratory infection. In order to better target precautions to mitigate risk, more research is required to determine the characteristics of medical procedures and patients that increase the risk of transmission of SARS-CoV-2.
Collapse
Affiliation(s)
- J Wilson
- Richard Wells Research Centre, University of West London, London, UK.
| | - G Carson
- Centre for Tropical Medicine and Global Health, Nuffield Department of Medicine, University of Oxford, Oxford, UK
| | - S Fitzgerald
- Department of Engineering, University of Cambridge, Cambridge, UK
| | - M J Llewelyn
- Brighton and Sussex Medical School, University of Sussex, Brighton, UK
| | - D Jenkins
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | - S Parker
- Defence Science and Technology Laboratory, Porton Down, Salisbury, UK
| | - A Boies
- Department of Engineering, University of Cambridge, Cambridge, UK
| | - J Thomas
- EPPI-Centre, Social Research Institute, UCL Institute of Education, University College London, London, UK
| | - K Sutcliffe
- EPPI-Centre, Social Research Institute, UCL Institute of Education, University College London, London, UK
| | - A J Sowden
- Centre for Reviews and Dissemination, University of York, York, UK
| | - A O'Mara-Eves
- EPPI-Centre, Social Research Institute, UCL Institute of Education, University College London, London, UK
| | - C Stansfield
- EPPI-Centre, Social Research Institute, UCL Institute of Education, University College London, London, UK
| | - E Harriss
- Bodleian Health Care Libraries, John Radcliffe Hospital, Oxford, UK
| | - J Reilly
- Research Centre for Health (ReaCH), Glasgow Caledonian University, Glasgow, UK
| |
Collapse
|
6
|
Schirmer A, Sessions R, Gravenstein N, Rand K, Oli M, Cooper LA, Sappenfield JW. Isolation gowns as a potential work hazard. Ann Work Expo Health 2021; 64:596-603. [PMID: 32374388 DOI: 10.1093/annweh/wxaa047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 04/13/2020] [Accepted: 04/22/2020] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES Isolation gowns are used as a barrier to bacterial transmission from patient to provider and vice versa. If an isolation gown is ineffective, the patient and provider have a potential breach of safety and increased infection risk. This study compared the bacterial permeability of differently rated, commonly uses isolation gowns to assess their effectiveness in preventing simulated bacterial transmittance, and thus contamination, from patient to provider. METHODS Serial dilutions of Staphylococcus epidermidis in sterile saline were applied to a simulated skin surface. Unrated and Levels 1 through 4 non-sterile isolation gowns contacted the solution, simulating patient contact. Both sides of the contaminated gowns were then cultured on blood agar by rolling a sterile swab across the gown and evenly inoculating the culture plate. Colony counts from inside and outside of the gowns were compared. Separately, S. epidermidis was placed on a sample of each gown and scanning electron microscopy was used to visualize the contaminated gowns' physical structure. RESULTS Mean bacterial transmittance from outside of the gown (i.e. patient contact side) to inside of the gowns (i.e. provider clothing or skin side) based on gown rating was as follows: unrated: 50.4% (SD 9.0%); Level 1: 39.7% (SD 11.2%); Level 2: 16.3% (SD 10.3%); Level 3: 0.3% (SD 0.8%); Level 4: 0.0% (SD 0.0%). Scanning electron microscope imaging of unrated, Level 1, and Level 2 gowns revealed gown pore sizes much larger than the bacteria. The Welch one-way analysis of variance statistic showed significant difference dependent on gown-level rating. CONCLUSIONS Unrated, Level 1, and Level 2 isolation gowns do not provide effective bacterial isolation barriers when bacteria like S. epidermidis make contact with one side of the gown material. Not studied, but implied, is that unrated and lower rated isolation gowns would be as or even more physically permeable to virus particles, which are much smaller than bacteria.
Collapse
Affiliation(s)
- Abigail Schirmer
- Florida State University College of Medicine, Tallahassee, FL, USA
| | - Renard Sessions
- Malcolm Randall Veteran's Affairs Medical Center, Gainesville, FL, USA
| | - Nikolaus Gravenstein
- Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA
| | - Kenneth Rand
- Department of Pathology, Immunology and Laboratory Medicine, University of Florida College of Medicine, Gainesville, FL, USA
| | - Monika Oli
- Microbiology and Cell Science, University of Florida, Institute of Food and Agricultural Sciences, Gainesville, FL, USA
| | - Lou Ann Cooper
- Office of Program Evaluation and Student Assessment, University of Florida College of Medicine, Gainesville, FL, USA
| | - Joshua W Sappenfield
- Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA
| |
Collapse
|
7
|
Zhang N, Chen W, Chan PT, Yen HL, Tang JWT, Li Y. Close contact behavior in indoor environment and transmission of respiratory infection. INDOOR AIR 2020; 30:645-661. [PMID: 32259319 DOI: 10.1111/ina.12673] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 02/29/2020] [Accepted: 03/25/2020] [Indexed: 05/05/2023]
Abstract
Close contact was first identified as the primary route of transmission for most respiratory infections in the early 20th century. In this review, we synthesize the existing understanding of the mechanisms of close contact transmission. We focus on two issues: the mechanism of transmission in close contact, namely the transmission of the expired particles between two people, and the physical parameters of close contact that affect the exposure of particles from one individual to another, or how the nature of close contact plays a role in transmission. We propose the existence of three sub-routes of transmission: short-range airborne, large droplets, and immediate body-surface contact. We also distinguish a "body contact," which is defined with an interpersonal distance of zero, from a close contact. We demonstrate herein that the short-range airborne sub-route may be most common. The timescales over which data should be collected to assess the transmission risk during close contact events are much shorter than those required for the distant airborne or fomite routes. The current paucity of high-resolution data over short distances and timescales makes it very difficult to assess the risk of infection in these circumstances.
Collapse
Affiliation(s)
- Nan Zhang
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Wenzhao Chen
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Pak-To Chan
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Hui-Ling Yen
- School of Public Health, The University of Hong Kong, Hong Kong, China
| | - Julian Wei-Tze Tang
- Clinical Microbiology, University Hospitals of Leicester NHS Trust, Leicester, UK
- Respiratory Sciences, University of Leicester, Leicester, UK
| | - Yuguo Li
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
- School of Public Health, The University of Hong Kong, Hong Kong, China
| |
Collapse
|
8
|
Thomas JP, Srinivasan A, Wickramarachchi CS, Dhesi PK, Hung YM, Kamath AV. Evaluating the national PPE guidance for NHS healthcare workers during the COVID-19 pandemic. Clin Med (Lond) 2020; 20:242-247. [PMID: 32357976 PMCID: PMC7354042 DOI: 10.7861/clinmed.2020-0143] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Tragically, many of the infections and deaths recorded in the global coronavirus disease 2019 (COVID-19) pandemic have occurred in healthcare workers. Some have attributed this to inadequate provision of personal protective equipment (PPE). In the UK, several organisations have voiced their concerns that the national PPE guidance issued by Public Health England is inadequate. Despite recent revisions to these guidelines, concerns remain that they offer insufficient protection to frontline NHS healthcare workers. In this report, we evaluate whether these concerns are merited, through critical appraisal of the available evidence, review of international PPE guidance, and consideration of the ethical implications.
Collapse
Affiliation(s)
- John P Thomas
- Norfolk and Norwich University Hospital, Norwich, UK
| | | | | | | | - Yat Ma Hung
- Norfolk and Norwich University Hospital, Norwich, UK
| | - Ajay V Kamath
- Norfolk and Norwich University Hospital, Norwich, UK
| |
Collapse
|
9
|
Verbeek JH, Rajamaki B, Ijaz S, Sauni R, Toomey E, Blackwood B, Tikka C, Ruotsalainen JH, Kilinc Balci FS. Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff. Cochrane Database Syst Rev 2020; 5:CD011621. [PMID: 32412096 PMCID: PMC8785899 DOI: 10.1002/14651858.cd011621.pub5] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND In epidemics of highly infectious diseases, such as Ebola, severe acute respiratory syndrome (SARS), or coronavirus (COVID-19), healthcare workers (HCW) are at much greater risk of infection than the general population, due to their contact with patients' contaminated body fluids. Personal protective equipment (PPE) can reduce the risk by covering exposed body parts. It is unclear which type of PPE protects best, what is the best way to put PPE on (i.e. donning) or to remove PPE (i.e. doffing), and how to train HCWs to use PPE as instructed. OBJECTIVES To evaluate which type of full-body PPE and which method of donning or doffing PPE have the least risk of contamination or infection for HCW, and which training methods increase compliance with PPE protocols. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase and CINAHL to 20 March 2020. SELECTION CRITERIA We included all controlled studies that evaluated the effect of full-body PPE used by HCW exposed to highly infectious diseases, on the risk of infection, contamination, or noncompliance with protocols. We also included studies that compared the effect of various ways of donning or doffing PPE, and the effects of training on the same outcomes. DATA COLLECTION AND ANALYSIS Two review authors independently selected studies, extracted data and assessed the risk of bias in included trials. We conducted random-effects meta-analyses were appropriate. MAIN RESULTS Earlier versions of this review were published in 2016 and 2019. In this update, we included 24 studies with 2278 participants, of which 14 were randomised controlled trials (RCT), one was a quasi-RCT and nine had a non-randomised design. Eight studies compared types of PPE. Six studies evaluated adapted PPE. Eight studies compared donning and doffing processes and three studies evaluated types of training. Eighteen studies used simulated exposure with fluorescent markers or harmless microbes. In simulation studies, median contamination rates were 25% for the intervention and 67% for the control groups. Evidence for all outcomes is of very low certainty unless otherwise stated because it is based on one or two studies, the indirectness of the evidence in simulation studies and because of risk of bias. Types of PPE The use of a powered, air-purifying respirator with coverall may protect against the risk of contamination better than a N95 mask and gown (risk ratio (RR) 0.27, 95% confidence interval (CI) 0.17 to 0.43) but was more difficult to don (non-compliance: RR 7.5, 95% CI 1.81 to 31.1). In one RCT (59 participants) coveralls were more difficult to doff than isolation gowns (very low-certainty evidence). Gowns may protect better against contamination than aprons (small patches: mean difference (MD) -10.28, 95% CI -14.77 to -5.79). PPE made of more breathable material may lead to a similar number of spots on the trunk (MD 1.60, 95% CI -0.15 to 3.35) compared to more water-repellent material but may have greater user satisfaction (MD -0.46, 95% CI -0.84 to -0.08, scale of 1 to 5). According to three studies that tested more recently introduced full-body PPE ensembles, there may be no difference in contamination. Modified PPE versus standard PPE The following modifications to PPE design may lead to less contamination compared to standard PPE: sealed gown and glove combination (RR 0.27, 95% CI 0.09 to 0.78), a better fitting gown around the neck, wrists and hands (RR 0.08, 95% CI 0.01 to 0.55), a better cover of the gown-wrist interface (RR 0.45, 95% CI 0.26 to 0.78, low-certainty evidence), added tabs to grab to facilitate doffing of masks (RR 0.33, 95% CI 0.14 to 0.80) or gloves (RR 0.22, 95% CI 0.15 to 0.31). Donning and doffing Using Centers for Disease Control and Prevention (CDC) recommendations for doffing may lead to less contamination compared to no guidance (small patches: MD -5.44, 95% CI -7.43 to -3.45). One-step removal of gloves and gown may lead to less bacterial contamination (RR 0.20, 95% CI 0.05 to 0.77) but not to less fluorescent contamination (RR 0.98, 95% CI 0.75 to 1.28) than separate removal. Double-gloving may lead to less viral or bacterial contamination compared to single gloving (RR 0.34, 95% CI 0.17 to 0.66) but not to less fluorescent contamination (RR 0.98, 95% CI 0.75 to 1.28). Additional spoken instruction may lead to fewer errors in doffing (MD -0.9, 95% CI -1.4 to -0.4) and to fewer contamination spots (MD -5, 95% CI -8.08 to -1.92). Extra sanitation of gloves before doffing with quaternary ammonium or bleach may decrease contamination, but not alcohol-based hand rub. Training The use of additional computer simulation may lead to fewer errors in doffing (MD -1.2, 95% CI -1.6 to -0.7). A video lecture on donning PPE may lead to better skills scores (MD 30.70, 95% CI 20.14 to 41.26) than a traditional lecture. Face-to-face instruction may reduce noncompliance with doffing guidance more (odds ratio 0.45, 95% CI 0.21 to 0.98) than providing folders or videos only. AUTHORS' CONCLUSIONS We found low- to very low-certainty evidence that covering more parts of the body leads to better protection but usually comes at the cost of more difficult donning or doffing and less user comfort. More breathable types of PPE may lead to similar contamination but may have greater user satisfaction. Modifications to PPE design, such as tabs to grab, may decrease the risk of contamination. For donning and doffing procedures, following CDC doffing guidance, a one-step glove and gown removal, double-gloving, spoken instructions during doffing, and using glove disinfection may reduce contamination and increase compliance. Face-to-face training in PPE use may reduce errors more than folder-based training. We still need RCTs of training with long-term follow-up. We need simulation studies with more participants to find out which combinations of PPE and which doffing procedure protects best. Consensus on simulation of exposure and assessment of outcome is urgently needed. We also need more real-life evidence. Therefore, the use of PPE of HCW exposed to highly infectious diseases should be registered and the HCW should be prospectively followed for their risk of infection.
Collapse
Affiliation(s)
- Jos H Verbeek
- Cochrane Work Review Group, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands
| | - Blair Rajamaki
- School of Pharmacy, University of Eastern Finland, Kuopio, Finland
| | - Sharea Ijaz
- Population Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK
| | | | | | - Bronagh Blackwood
- Centre for Experimental Medicine, School of Medicine, Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK
| | - Christina Tikka
- Finnish Institute of Occupational Health, TYÖTERVEYSLAITOS, Finland
| | | | - F Selcen Kilinc Balci
- National Personal Protective Technology Laboratory (NPPTL), National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), Pittsburgh, PA, USA
| |
Collapse
|
10
|
Verbeek JH, Rajamaki B, Ijaz S, Sauni R, Toomey E, Blackwood B, Tikka C, Ruotsalainen JH, Kilinc Balci FS. Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff. Cochrane Database Syst Rev 2020; 4:CD011621. [PMID: 32293717 PMCID: PMC7158881 DOI: 10.1002/14651858.cd011621.pub4] [Citation(s) in RCA: 163] [Impact Index Per Article: 40.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
BACKGROUND In epidemics of highly infectious diseases, such as Ebola, severe acute respiratory syndrome (SARS), or coronavirus (COVID-19), healthcare workers (HCW) are at much greater risk of infection than the general population, due to their contact with patients' contaminated body fluids. Personal protective equipment (PPE) can reduce the risk by covering exposed body parts. It is unclear which type of PPE protects best, what is the best way to put PPE on (i.e. donning) or to remove PPE (i.e. doffing), and how to train HCWs to use PPE as instructed. OBJECTIVES To evaluate which type of full-body PPE and which method of donning or doffing PPE have the least risk of contamination or infection for HCW, and which training methods increase compliance with PPE protocols. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase and CINAHL to 20 March 2020. SELECTION CRITERIA We included all controlled studies that evaluated the effect of full-body PPE used by HCW exposed to highly infectious diseases, on the risk of infection, contamination, or noncompliance with protocols. We also included studies that compared the effect of various ways of donning or doffing PPE, and the effects of training on the same outcomes. DATA COLLECTION AND ANALYSIS Two review authors independently selected studies, extracted data and assessed the risk of bias in included trials. We conducted random-effects meta-analyses were appropriate. MAIN RESULTS Earlier versions of this review were published in 2016 and 2019. In this update, we included 24 studies with 2278 participants, of which 14 were randomised controlled trials (RCT), one was a quasi-RCT and nine had a non-randomised design. Eight studies compared types of PPE. Six studies evaluated adapted PPE. Eight studies compared donning and doffing processes and three studies evaluated types of training. Eighteen studies used simulated exposure with fluorescent markers or harmless microbes. In simulation studies, median contamination rates were 25% for the intervention and 67% for the control groups. Evidence for all outcomes is of very low certainty unless otherwise stated because it is based on one or two studies, the indirectness of the evidence in simulation studies and because of risk of bias. Types of PPE The use of a powered, air-purifying respirator with coverall may protect against the risk of contamination better than a N95 mask and gown (risk ratio (RR) 0.27, 95% confidence interval (CI) 0.17 to 0.43) but was more difficult to don (non-compliance: RR 7.5, 95% CI 1.81 to 31.1). In one RCT (59 participants), people with a long gown had less contamination than those with a coverall, and coveralls were more difficult to doff (low-certainty evidence). Gowns may protect better against contamination than aprons (small patches: mean difference (MD) -10.28, 95% CI -14.77 to -5.79). PPE made of more breathable material may lead to a similar number of spots on the trunk (MD 1.60, 95% CI -0.15 to 3.35) compared to more water-repellent material but may have greater user satisfaction (MD -0.46, 95% CI -0.84 to -0.08, scale of 1 to 5). Modified PPE versus standard PPE The following modifications to PPE design may lead to less contamination compared to standard PPE: sealed gown and glove combination (RR 0.27, 95% CI 0.09 to 0.78), a better fitting gown around the neck, wrists and hands (RR 0.08, 95% CI 0.01 to 0.55), a better cover of the gown-wrist interface (RR 0.45, 95% CI 0.26 to 0.78, low-certainty evidence), added tabs to grab to facilitate doffing of masks (RR 0.33, 95% CI 0.14 to 0.80) or gloves (RR 0.22, 95% CI 0.15 to 0.31). Donning and doffing Using Centers for Disease Control and Prevention (CDC) recommendations for doffing may lead to less contamination compared to no guidance (small patches: MD -5.44, 95% CI -7.43 to -3.45). One-step removal of gloves and gown may lead to less bacterial contamination (RR 0.20, 95% CI 0.05 to 0.77) but not to less fluorescent contamination (RR 0.98, 95% CI 0.75 to 1.28) than separate removal. Double-gloving may lead to less viral or bacterial contamination compared to single gloving (RR 0.34, 95% CI 0.17 to 0.66) but not to less fluorescent contamination (RR 0.98, 95% CI 0.75 to 1.28). Additional spoken instruction may lead to fewer errors in doffing (MD -0.9, 95% CI -1.4 to -0.4) and to fewer contamination spots (MD -5, 95% CI -8.08 to -1.92). Extra sanitation of gloves before doffing with quaternary ammonium or bleach may decrease contamination, but not alcohol-based hand rub. Training The use of additional computer simulation may lead to fewer errors in doffing (MD -1.2, 95% CI -1.6 to -0.7). A video lecture on donning PPE may lead to better skills scores (MD 30.70, 95% CI 20.14 to 41.26) than a traditional lecture. Face-to-face instruction may reduce noncompliance with doffing guidance more (odds ratio 0.45, 95% CI 0.21 to 0.98) than providing folders or videos only. AUTHORS' CONCLUSIONS We found low- to very low-certainty evidence that covering more parts of the body leads to better protection but usually comes at the cost of more difficult donning or doffing and less user comfort, and may therefore even lead to more contamination. More breathable types of PPE may lead to similar contamination but may have greater user satisfaction. Modifications to PPE design, such as tabs to grab, may decrease the risk of contamination. For donning and doffing procedures, following CDC doffing guidance, a one-step glove and gown removal, double-gloving, spoken instructions during doffing, and using glove disinfection may reduce contamination and increase compliance. Face-to-face training in PPE use may reduce errors more than folder-based training. We still need RCTs of training with long-term follow-up. We need simulation studies with more participants to find out which combinations of PPE and which doffing procedure protects best. Consensus on simulation of exposure and assessment of outcome is urgently needed. We also need more real-life evidence. Therefore, the use of PPE of HCW exposed to highly infectious diseases should be registered and the HCW should be prospectively followed for their risk of infection.
Collapse
Affiliation(s)
- Jos H Verbeek
- Academic Medical Center, University of Amsterdam, Cochrane Work Review Group, Amsterdam, Netherlands, 1105AZ
| | - Blair Rajamaki
- University of Eastern Finland, School of Pharmacy, Kuopio, Finland
| | - Sharea Ijaz
- University of Bristol, Population Health Sciences, Bristol Medical School, Bristol, UK, BS1 2NT
| | | | | | - Bronagh Blackwood
- Queen's University Belfast, Centre for Experimental Medicine, School of Medicine, Dentistry and Biomedical Sciences, Wellcome-Wolfson Building, 97 Lisburn Road, Belfast, Northern Ireland, UK, BT9 7LB
| | - Christina Tikka
- Finnish Institute of Occupational Health, TYÖTERVEYSLAITOS, Finland, FI-70032
| | - Jani H Ruotsalainen
- Finnish Medicines Agency, Assessment of Pharmacotherapies, Microkatu 1, Kuopio, Finland, FI-70210
| | - F Selcen Kilinc Balci
- Centers for Disease Control and Prevention (CDC), National Personal Protective Technology Laboratory (NPPTL), National Institute for Occupational Safety and Health (NIOSH), 626 Cochrans Mill Road, Pittsburgh, PA, USA, 15236
| |
Collapse
|
11
|
Jones RM, Bleasdale SC, Maita D, Brosseau LM. A systematic risk-based strategy to select personal protective equipment for infectious diseases. Am J Infect Control 2020; 48:46-51. [PMID: 31358421 PMCID: PMC7132808 DOI: 10.1016/j.ajic.2019.06.023] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Revised: 06/18/2019] [Accepted: 06/19/2019] [Indexed: 01/20/2023]
Abstract
Selection of personal protective equipment (PPE) can be systematic and risk-based. Potential exposures are compared with sites susceptible to infection. Facilitates transparent decision-making about personal protective equipment. PPE evaluation includes: donning/doffing/changing, usability, and fit for purpose.
Background Personal protective equipment (PPE) is a primary strategy to protect health care personnel (HCP) from infectious diseases. When transmission-based PPE ensembles are not appropriate, HCP must recognize the transmission pathway of the disease and anticipate the exposures to select PPE. Because guidance for this process is extremely limited, we proposed a systematic, risk-based approach to the selection and evaluation of PPE ensembles to protect HCP against infectious diseases. Methods The approach used in this study included the following 4 steps: (1) job hazard analysis, (2) infectious disease hazard analysis, (3) selection of PPE, and (4) evaluation of selected PPE. Selected PPE should protect HCP from exposure, be usable by HCP, and fit for purpose. Results The approach was demonstrated for the activity of intubation of a patient with methicillin-resistant Staphylococcus aureus or Severe Acute Respiratory Syndrome coronavirus. As expected, the approach led to the selection of different ensembles of PPE for these 2 pathogens. Discussion A systematic risk-based approach to the selection of PPE will help health care facilities and HCP select PPE when transmission-based precautions are not appropriate. Owing to the complexity of PPE ensemble selection and evaluation, a team with expertise in infectious diseases, occupational health, the health care activity, and related disciplines, such as human factors, should be engaged. Conclusions Participation, documentation, and transparency are necessary to ensure the decisions can be communicated, critiqued, and understood by HCP.
Collapse
Affiliation(s)
- Rachael M Jones
- School of Public Health, Division of Environmental and Occupational Health Sciences, University of Illinois at Chicago, Chicago, IL; School of Medicine, Department of Family and Preventive Medicine, University of Utah, Salt Lake City, UT.
| | - Susan C Bleasdale
- College of Medicine, Department of Medicine, University of Illinois at Chicago, Chicago, IL
| | - Dayana Maita
- College of Medicine, Department of Medicine, University of Illinois at Chicago, Chicago, IL
| | - Lisa M Brosseau
- School of Public Health, Division of Environmental and Occupational Health Sciences, University of Illinois at Chicago, Chicago, IL
| |
Collapse
|