1
|
Chen MC, Hsieh MM, Huang XY. Ultrasensitive enantiomeric barbiturate analysis in body fluids through capillary electrophoresis with large volume sample stacking and ultrasound assisted dispersive liquid liquid microextraction. J Chromatogr A 2024; 1730:465103. [PMID: 38917679 DOI: 10.1016/j.chroma.2024.465103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 06/03/2024] [Accepted: 06/16/2024] [Indexed: 06/27/2024]
Abstract
A rapid, straightforward, and sensitive approach to quantifying enantiomeric barbiturates in serum was developed by integrating ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) with large-volume sample stacking (LVSS) in capillary electrophoresis (CE). UA-DLLME was employed for sample preparation, and on-column preconcentration by using LVSS with polarity switching was implemented to enhance sensitivity. We thoroughly investigated and optimized various parameters influencing extraction and stacking to achieve optimal detection performance with the highest enrichment efficiencies. Under optimal extraction conditions (injection of a mixed solution containing 40 μL of CHCl3 and 200 μL of tetrahydrofuran into 1 mL of a sample solution at pH 10.0), LVSS was performed using 600 mM Tris-boric acid (pH 9.5) containing 35 mM hydroxypropyl-β-cyclodextrin and sodium taurodeoxycholate hydrate. A voltage of 20 kV was applied and a preinjection water plug was loaded at a height of 25 cm for 10 s. Subsequently, the sample solution was injected at a height of 25 cm for 480 s, after which a voltage of -20 kV was applied and the sample stacking was initiated. The stacking process was completed when 95 % of the separation current was attained. Under optimized conditions, the contraction folds of the four barbiturate analytes (R, S-Secobarbital, R, S-pentobarbital) were improved by approximately 6400-fold, achieving detection limits of 0.1 ng/mL. The limits of quantification for all analyte enantiomers were 0.5-50 ng/mL, demonstrating good linearity (r > 0.997). Migration times exhibited a relative standard deviation of less than 1.7 %, whereas peak areas for the four analytes exhibited a deviation of 8.7 %. Finally, the established method was effectively applied to the analysis of human serum samples.
Collapse
Affiliation(s)
- Meng-Chin Chen
- Department of Chemistry, National Kaohsiung Normal University, Taiwan
| | - Ming-Mu Hsieh
- Department of Chemistry, National Kaohsiung Normal University, Taiwan.
| | - Xin-Yu Huang
- Department of Chemistry, National Kaohsiung Normal University, Taiwan
| |
Collapse
|
2
|
CHI Z, YANG L. Advances in chiral separation and analysis by capillary electrophoresis-mass spectrometry. Se Pu 2022; 40:509-519. [PMID: 35616196 PMCID: PMC9404244 DOI: 10.3724/sp.j.1123.2021.11006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
目前使用的绝大多数药物为手性化合物,它们具有相似的物理和化学性质,但药理活性不同,且常以外消旋混合物的形式存在,因此对手性化合物的分离在生物、环境、食品和医药等领域一直备受关注。与广泛使用的液相色谱-质谱(LC-MS)相比,毛细管电泳-质谱(CE-MS)作为一种新型分离分析技术,具有分离效率高、样品和试剂消耗量低、选择性高和分离模式多样化等诸多优势,已经发展成为手性分析领域中有广阔应用前景的分析方法之一。CE-MS结合了CE的高分离效率和低样品消耗以及MS的高灵敏度和强结构解析能力,在蛋白质组学和代谢组学等领域发挥了重要作用。CE杰出的手性拆分能力与MS优势的结合,亦使CE-MS成为实现手性化合物高效分离分析的完美组合。在过去的十几年里,基于不同CE-MS分离模式的高性能手性分析体系层出不穷,如电动色谱-质谱(EKC-MS)、胶束电动色谱-质谱(MEKC-MS)和毛细管电色谱-质谱(CEC-MS)等,并成功应用于医药、生物、食品和环境科学等领域的手性化合物分析。该文主要综述了2011~2021年,CE-MS在手性化合物分析领域的技术、手性选择剂(如改性环糊精和聚合物表面活性剂等)的使用以及在医药等领域应用方面的研究进展,并讨论了不同手性分析模式的局限性,为未来的CE-MS手性分离分析技术发展及应用提供借鉴。
Collapse
|
3
|
de Koster N, Clark CP, Kohler I. Past, present, and future developments in enantioselective analysis using capillary electromigration techniques. Electrophoresis 2021; 42:38-57. [PMID: 32914880 PMCID: PMC7821218 DOI: 10.1002/elps.202000151] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 08/22/2020] [Accepted: 09/08/2020] [Indexed: 12/16/2022]
Abstract
Enantioseparation of chiral products has become increasingly important in a large diversity of academic and industrial applications. The separation of chiral compounds is inherently challenging and thus requires a suitable analytical technique that can achieve high resolution and sensitivity. In this context, CE has shown remarkable results so far. Chiral CE offers an orthogonal enantioselectivity and is typically considered less costly than chromatographic techniques, since only minute amounts of chiral selectors are needed. Several CE approaches have been developed for chiral analysis, including chiral EKC and chiral CEC. Enantioseparations by EKC benefit from the wide variety of possible pseudostationary phases that can be employed. Chiral CEC, on the other hand, combines chromatographic separation principles with the bulk fluid movement of CE, benefitting from reduced band broadening as compared to pressure-driven systems. Although UV detection is conventionally used for these approaches, MS can also be considered. CE-MS represents a promising alternative due to the increased sensitivity and selectivity, enabling the chiral analysis of complex samples. The potential contamination of the MS ion source in EKC-MS can be overcome using partial-filling and counter-migration techniques. However, chiral analysis using monolithic and open-tubular CEC-MS awaits additional method validation and a dedicated commercial interface. Further efforts in chiral CE are expected toward the improvement of existing techniques, the development of novel pseudostationary phases, and establishing the use of chiral ionic liquids, molecular imprinted polymers, and metal-organic frameworks. These developments will certainly foster the adoption of CE(-MS) as a well-established technique in routine chiral analysis.
Collapse
Affiliation(s)
- Nicky de Koster
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Charles P. Clark
- Leiden Academic Centre for Drug Research, Division of Systems Biomedicine and PharmacologyLeiden UniversityLeidenThe Netherlands
| | - Isabelle Kohler
- Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute for Molecular and Life SciencesVrije Universiteit AmsterdamAmsterdamThe Netherlands
| |
Collapse
|
4
|
Chiral Micellar Electrokinetic Chromatography. J Chromatogr A 2020; 1626:461383. [PMID: 32797856 DOI: 10.1016/j.chroma.2020.461383] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/29/2020] [Accepted: 06/30/2020] [Indexed: 12/18/2022]
Abstract
The potential of Micellar Electrokinetic Chromatography to achieve enantiomeric separations is reviewed in this article. The separation principles and the most frequently employed separation strategies to achieve chiral separations by Micellar Electrokinetic Chromatography are described. The use of chiral micellar systems alone or combined with other micellar systems or chiral selectors, as well as of mixtures of achiral micellar systems with chiral selectors is discussed together with the effect of different additives present in the separation medium. Indirect methods based on the derivatization of analytes with chiral derivatizing reagents and the use of achiral micelles are also considered. Preconcentration techniques employed to improve sensitivity and the main approaches developed to facilitate the coupling with Mass Spectrometry are included. The most recent and relevant methodologies developed by chiral Micellar Electrokinetic Chromatography and their applications in different fields are presented.
Collapse
|
5
|
Casado N, Valimaña-Traverso J, García MÁ, Marina ML. Enantiomeric Determination of Drugs in Pharmaceutical Formulations and Biological Samples by Electrokinetic Chromatography. Crit Rev Anal Chem 2019; 50:554-584. [PMID: 31569950 DOI: 10.1080/10408347.2019.1670043] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Chirality is a relevant issue in the pharmaceutical field due to the different biological activity that enantiomers of a chiral drug can show. In fact, the desired biological or pharmaceutical activity might be present in only one of the enantiomers, while the other enantiomer(s) may have different biological activity, be inactive or even toxic. This has motivated in recent years the development of drugs marketed as pure enantiomers to avoid exposing the organism to the action of enantiomers that may not be active or even harmful to health. Thus, it is of high interest to develop enantioselective analytical methodologies to control the presence of enantiomeric impurities and to understand the enantioselective metabolism of chiral drugs. This review gives an overview about the analytical strategies developed by electrokinetic chromatography (EKC) from 2010 to June 2019 for the enantiomeric determination of drugs in both pharmaceutical formulations and biological samples. The types of chiral selectors used, the migration order of enantiomers, their resolution, the detection technique employed and the sensitivity achieved are revised and compared. Also, applications to assess the enantiomeric purity control of pharmaceutical formulations and to determine chiral drugs in biological samples to study their metabolism are included. Advantages and limitations of the chiral methods developed by EKC are also discussed.
Collapse
Affiliation(s)
- Natalia Casado
- Departamento de Química Analítica, Química Física e Ingeniería Química, Universidad de Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, Madrid, Spain
| | - Jesús Valimaña-Traverso
- Departamento de Química Analítica, Química Física e Ingeniería Química, Universidad de Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, Madrid, Spain
| | - María Ángeles García
- Departamento de Química Analítica, Química Física e Ingeniería Química, Universidad de Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, Madrid, Spain.,Instituto de Investigación Química, "Andrés M. del Río" (IQAR), Universidad de Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, Madrid, Spain
| | - María Luisa Marina
- Departamento de Química Analítica, Química Física e Ingeniería Química, Universidad de Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, Madrid, Spain.,Instituto de Investigación Química, "Andrés M. del Río" (IQAR), Universidad de Alcalá, Ctra. Madrid-Barcelona Km. 33.600, Alcalá de Henares, Madrid, Spain
| |
Collapse
|
6
|
Javed S, Ahsan W. Microemulsion based chromatographic techniques: Past lessons and future directions. J LIQ CHROMATOGR R T 2019. [DOI: 10.1080/10826076.2019.1584746] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Shamama Javed
- Department of Pharmaceutics, College of Pharmacy, Jazan University, Jazan, Saudi Arabia
| | - Waquar Ahsan
- Department of Pharmaceutical Chemistry, College of Pharmacy, Jazan University, Jazan, Saudi Arabia
| |
Collapse
|
7
|
Patel V, Shamsi SA. Carbohydrate-Based Polymeric Surfactants for Chiral Micellar Electrokinetic Chromatography (CMEKC) Coupled to Mass Spectrometry. Methods Mol Biol 2019; 1985:417-444. [PMID: 31069750 PMCID: PMC7199777 DOI: 10.1007/978-1-4939-9438-0_25] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
Polymeric surfactants (molecular micelles, MoMs) with a variety of chiral head groups and chain lengths may be the most promising chiral selectors when used for sensitive detection of chiral compounds in micellar electrokinetic chromatography-mass spectrometry (MEKC-MS). Various carbohydrate-based MS compatible surfactants with phosphate and sulfate head groups have been recently synthesized in our laboratory for its application in CMEKC-MS. In this chapter, we illustrate that the synthesized glucopyranoside-based MoMs are fully compatible with electrospray ionization MS and can be successfully used as a chiral selector for high-throughput screening of multiple chiral compounds using MRM mode in CMEKC-MS/MS experiments. This chapter describes in detail synthesis and utility of α- and β-glucopyranoside-based polymeric surfactant with two different chain lengths and head groups. The presented examples optimize the effect of appropriate millimolar concentration of monomer sugar surfactants required for polymerization as it affects the separations of acidic and basic compounds. Under the optimized concentration of the monomer needed for polymerization (i.e., an equivalent monomer concentration of MoMs), the superiority of MEKC-MS over MEKC-UV is evident. Structurally similar basic drugs with the difference in hydrophobicity are first tested in MEKC-MS to find the optimum head group and optimum chain length with the aim for developing a widely applicable polymeric glucopyranoside-based surfactant. The partial enantioresolution of several structurally similar basic compounds is significantly improved when switching from one head group to another head group of the glucopyranoside MoMs. Thus, complementary separations using poly-N-β-D-SUGP versus poly-N-β-D-SUGS were seen. This phenomenon also exists when comparing the MoMs, which differ in an anomeric configuration such as poly-N-α-D-SUGP and poly-N-β-D-SUGP.
Collapse
Affiliation(s)
- Vijay Patel
- Department of Chemistry, Georgia State University, Natural Science Center, Atlanta, GA, USA
| | - Shahab A Shamsi
- Department of Chemistry, Georgia State University, Natural Science Center, Atlanta, GA, USA.
| |
Collapse
|
8
|
Zhang X, Lin Z, Li J, Huang Z, Rao Y, Liang H, Yan J, Zheng F. Rapid determination of nine barbiturates in human whole blood by liquid chromatography-tandem mass spectrometry. Drug Test Anal 2016; 9:588-595. [DOI: 10.1002/dta.2002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Revised: 04/26/2016] [Accepted: 05/08/2016] [Indexed: 11/10/2022]
Affiliation(s)
- Xinyu Zhang
- Department of Pharmaceutical Analysis; China Pharmaceutical University; Nanjing Jiangsu PR China
- Department of Forensic Medicine, School of Basic Medical Sciences; Fudan University; Shanghai PR China
| | - Zebin Lin
- Department of Forensic Medicine, School of Basic Medical Sciences; Fudan University; Shanghai PR China
| | - Jiaolun Li
- Department of Chemistry; Fudan University; Shanghai PR China
| | - Zhibin Huang
- Department of Forensic Medicine, School of Basic Medical Sciences; Fudan University; Shanghai PR China
| | - Yulan Rao
- Department of Forensic Medicine, School of Basic Medical Sciences; Fudan University; Shanghai PR China
| | - Hao Liang
- Department of Forensic Medicine, School of Basic Medical Sciences; Fudan University; Shanghai PR China
| | - Jie Yan
- Department of Forensic Science, School of Basic Medical Sciences; Central South University; Changsha Hunan PR China
| | - Feng Zheng
- Department of Pharmaceutical Analysis; China Pharmaceutical University; Nanjing Jiangsu PR China
| |
Collapse
|
9
|
Liu Y, Shamsi SA. Chiral Capillary Electrophoresis-Mass Spectrometry: Developments and Applications in the Period 2010-2015: A Review. J Chromatogr Sci 2016; 54:1771-1786. [PMID: 27371855 DOI: 10.1093/chromsci/bmw100] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Indexed: 11/14/2022]
Abstract
The sensitive detection of chiral compounds by capillary electrophoresis (CE) in biological samples remains a significant challenge and is currently considered a bottleneck in many chiral analysis projects. Chiral CE-MS can significantly improve the limit of detection and provide high sensitivity compared with chiral CE-UV. Chiral selectors such as modified cyclodextrins (CDs) and polymeric surfactants (a.k.a. molecular micelles, MoMs) in electrokinetic chromatography (EKC), micellar electrokinetic chromatography (MEKC) and capillary electrochromatography (CEC) have been developed to address the need for high sensitivity by CE-MS. However, several problems remain to be investigated to fully understand the potential of these hyphenation modes. This review provides introduction to major chiral CE-MS modes for the novice and highlights the important working principles of each mode of chiral CE-MS. Next, recent practical developments and progress in chiral CE-MS dating from January 2010 to September 2015 are described. The achievements in clinical and biomedical sciences using a variety of chiral selectors such as CDs and MoMs in EKC-MS, MEKC-MS and CEC-MS are discussed. Finally, conclusions and future prospects of CE-MS in chiral analysis are drafted.
Collapse
Affiliation(s)
- Yijin Liu
- Department of Chemistry, Georgia State University, Atlanta, GA 30303, USA
| | - Shahab A Shamsi
- Department of Chemistry, Georgia State University, Atlanta, GA 30303, USA
| |
Collapse
|
10
|
Piešťanský J, Maráková K, Kovaľ M, Havránek E, Mikuš P. Enantioselective column coupled electrophoresis employing large bore capillaries hyphenated with tandem mass spectrometry for ultra-trace determination of chiral compounds in complex real samples. Electrophoresis 2015; 36:3069-79. [DOI: 10.1002/elps.201500351] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Revised: 09/07/2015] [Accepted: 09/07/2015] [Indexed: 12/18/2022]
Affiliation(s)
- Juraj Piešťanský
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy; Comenius University in Bratislava; Bratislava Slovak Republic
- Toxicological and Antidoping Center, Faculty of Pharmacy; Comenius University in Bratislava; Bratislava Slovak Republic
| | - Katarína Maráková
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy; Comenius University in Bratislava; Bratislava Slovak Republic
- Toxicological and Antidoping Center, Faculty of Pharmacy; Comenius University in Bratislava; Bratislava Slovak Republic
| | - Marián Kovaľ
- Villa Labeco spol. s r. o; Spišská Nová Ves Slovak Republic
| | - Emil Havránek
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy; Comenius University in Bratislava; Bratislava Slovak Republic
| | - Peter Mikuš
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy; Comenius University in Bratislava; Bratislava Slovak Republic
- Toxicological and Antidoping Center, Faculty of Pharmacy; Comenius University in Bratislava; Bratislava Slovak Republic
| |
Collapse
|
11
|
Wuethrich A, Haddad PR, Quirino JP. Online sample concentration in partial-filling chiral electrokinetic chromatography – mass spectrometry. Chirality 2015; 26:734-8. [PMID: 25513680 DOI: 10.1002/chir.22257] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The concentration sensitivity of a racemic drug (chlorpheniramine maleate) in chiral capillary electrophoresis with electrospray ionization – mass spectrometric detection was improved ~500-fold via stacking. Enantiomeric separation was achieved through the use of a neutral chiral pseudostationary phase (2-hydroxpropyl-β-cyclodextrin), untreated fused-silica capillaries, and the application of a partial-filling technique to prevent the pseudostationary phase from entering the detector. A concentration factor of 50 resulted from field-enhanced sample injection(FESI). However, the higher concentration factor was achieved by combining FESI with micelle-to-solvent stacking (MSS) to increase sample load and focus the analyte band. MSS was achieved by injection of an ammonium lauryl sulfate micellar plug prior to sample injection. The sample diluent was a 20-fold dilution of the background electrolyte (50 mM ammonium acetate, pH 3.5) with 60% acetonitrile. This methodology provided a limit of detection (LOD) of as low as 5 ng/ml of the racemate.
Collapse
|
12
|
Lin L, Lv J, Ji Y, Feng J, Liu Y, Wang Z, Zhang W. Characterization of Barbiturates by Infrared and Raman Microscopy. ANAL LETT 2013. [DOI: 10.1080/00032719.2013.816964] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
13
|
Wuethrich A, Haddad PR, Quirino JP. Chiral capillary electromigration techniques-mass spectrometry-hope and promise. Electrophoresis 2013; 35:2-11. [PMID: 24265218 DOI: 10.1002/elps.201300377] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2013] [Revised: 10/06/2013] [Accepted: 10/07/2013] [Indexed: 11/09/2022]
Abstract
Analytical methods for chiral compounds require a separation step prior to mass spectrometric detection. CE can separate enantiomers by the use of a chiral selector and can be hyphenated with MS. The chiral selector can be either embedded inside the capillary (electrochromatography) or added into the background solution (EKC). This review describes the fundamentals and highlights the recent developments (September 2009-May 2013) of chiral CEC and EKC with detection using MS. There were 20 research and more than 30 review papers during this period. The research efforts were driven by fundamental studies, such as the development of novel chiral selectors in electrochromatography and of advanced partial filling techniques in EKC in order to optimise separation. Other developments were in application studies, such as in food analytics and metabolomics.
Collapse
Affiliation(s)
- Alain Wuethrich
- Australian Centre for Research on Separation Science (ACROSS), School of Chemistry, University of Tasmania, Hobart, Australia
| | | | | |
Collapse
|
14
|
Orlandini S, Gotti R, Furlanetto S. Multivariate optimization of capillary electrophoresis methods: a critical review. J Pharm Biomed Anal 2013; 87:290-307. [PMID: 23669025 DOI: 10.1016/j.jpba.2013.04.014] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2013] [Accepted: 04/12/2013] [Indexed: 11/19/2022]
Abstract
In this article a review on the recent applications of multivariate techniques for optimization of electromigration methods, is presented. Papers published in the period from August 2007 to February 2013, have been taken into consideration. Upon a brief description of each of the involved CE operative modes, the characteristics of the chemometric strategies (type of design, factors and responses) applied to face a number of analytical challenges, are presented. Finally, a critical discussion, giving some practical advices and pointing out the most common issues involved in multivariate set-up of CE methods, is provided.
Collapse
Affiliation(s)
- Serena Orlandini
- Department of Chemistry "U. Schiff", University of Florence, Via U. Schiff 6, 50019 Sesto Fiorentino, Florence, Italy
| | | | | |
Collapse
|
15
|
He J, Shamsi SA. Application of polymeric surfactants in chiral micellar electrokinetic chromatography (CMEKC) and CMEKC coupled to mass spectrometry. Methods Mol Biol 2013; 970:319-348. [PMID: 23283788 DOI: 10.1007/978-1-62703-263-6_21] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The use of amino acid-based polymeric surfactants (a.k.a. molecular micelles) in chiral micellar electrokinetic chromatography (CMEKC) has been shown to be a successful separation mode for capillary electrophoresis (CE). In this mode, chiral compounds can be enantioseparated with high efficiency, high chiral selectivity, and versatility. This chapter describes the state-of-the art studies published in the past 5 years in CMEKC using polymeric surfactants. Recent trends in the compatibility of chiral polymeric surfactants with mass spectrometric (MS) detection suggest that this type of chiral selector may be the most promising ones for chiral CE-MS applications. The synthesis of new anionic and cationic MS-compatible polymeric surfactants and their utility in CMEKC and CMEKC-MS are demonstrated. Examples of how to run a typical CMEKC-MS experiment using univariate and multivariate optimization of CMEKC and MS parameters are discussed.
Collapse
Affiliation(s)
- Jun He
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA, USA
| | | |
Collapse
|
16
|
Silva M. Micellar electrokinetic chromatography: A review of methodological and instrumental innovations focusing on practical aspects. Electrophoresis 2012; 34:141-58. [DOI: 10.1002/elps.201200349] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 07/25/2012] [Accepted: 07/25/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Manuel Silva
- Department of Analytical Chemistry, Rabanales Campus; University of Cordoba; Cordoba; Spain
| |
Collapse
|
17
|
Schwaninger AE, Meyer MR, Maurer HH. Chiral drug analysis using mass spectrometric detection relevant to research and practice in clinical and forensic toxicology. J Chromatogr A 2012; 1269:122-35. [DOI: 10.1016/j.chroma.2012.07.045] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2012] [Revised: 07/14/2012] [Accepted: 07/17/2012] [Indexed: 12/01/2022]
|
18
|
Affiliation(s)
- Timothy J. Ward
- Millsaps College, 1701 N. State Street, Box 150306, Jackson, Mississippi 39210, United States
| | - Karen D. Ward
- Millsaps College, 1701 N. State Street, Box 150306, Jackson, Mississippi 39210, United States
| |
Collapse
|
19
|
Sánchez-Hernández L, Castro-Puyana M, Marina ML, Crego AL. Recent approaches in sensitive enantioseparations by CE. Electrophoresis 2011; 33:228-42. [PMID: 22144098 DOI: 10.1002/elps.201100404] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2011] [Revised: 09/16/2011] [Accepted: 09/17/2011] [Indexed: 12/27/2022]
Abstract
The latest strategies and instrumental improvements for enhancing the detection sensitivity in chiral analysis by CE are reviewed in this work. Following the previous reviews by García-Ruiz et al. (Electrophoresis 2006, 27, 195-212) and Sánchez-Hernández et al. (Electrophoresis 2008, 29, 237-251; Electrophoresis 2010, 31, 28-43), this review includes those papers that were published during the period from June 2009 to May 2011. These works describe the use of offline and online sample treatment techniques, online sample preconcentration techniques based on electrophoretic principles, and alternative detection systems to UV-Vis to increase the detection sensitivity. The application of the above-mentioned strategies, either alone or combined, to improve the sensitivity in the enantiomeric analysis of a broad range of samples, such as pharmaceutical, biological, food and environmental samples, enables to decrease the limits of detection up to 10⁻¹² M. The use of microchips to achieve sensitive chiral separations is also discussed.
Collapse
Affiliation(s)
- Laura Sánchez-Hernández
- Department of Analytical Chemistry, Faculty of Chemistry, University of Alcalá. Ctra. Madrid-Barcelona, Alcalá de Henares, Madrid, Spain
| | | | | | | |
Collapse
|