Trines SA, Moore P, Burri H, Gonçalves Nunes S, Massoullié G, Merino JL, Paton MF, Porta-Sánchez A, Sommer P, Steven D, Whittaker-Axon S, Yorgun H. 2024 updated European Heart Rhythm Association core curriculum for physicians and allied professionals: a statement of the European Heart Rhythm Association of the European Society of Cardiology. Europace 2024; 26:euae243. [PMID: 39298665 PMCID: PMC11528301 DOI: 10.1093/europace/euae243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Accepted: 09/12/2024] [Indexed: 09/22/2024] Open
Abstract
Heart rhythm management is a continuously evolving sub-speciality of cardiology. Every year, many physicians and allied professionals (APs) start and complete their training in cardiac implantable electronic devices (CIEDs) or electrophysiology (EP) across the European Heart Rhythm Association (EHRA) member countries. While this training ideally ends with an EHRA certification, the description of the learning pathway (what, how, when, and where) through an EHRA core curriculum is also a prerequisite for a successful training. The first EHRA core curriculum for physicians was published in 2009. Due to the huge developments in the field of EP and device therapy, this document needed updating. In addition, a certification process for APs has been introduced, as well as a recertification process and accreditation of EHRA recognized training centres. Learning pathways are more individualized now, with Objective Structured Assessment of Technical Skills (OSATS) to monitor learning progression of trainees. The 2024 updated EHRA core curriculum for physicians and APs describes, for both CIED and EP, the syllabus, OSATS, training programme and certification, and recertification for physicians and APs and stresses the importance of continued medical education after certification. In addition, requirements for accreditation of training centres and trainers are given. Finally, suggested reading lists for CIED and EP are attached as online supplements.
Collapse
Affiliation(s)
- Serge A Trines
- Department of Cardiology, Heart Lung Centre, Leiden University Medical Centre, Leiden, The Netherlands
| | - Philip Moore
- Barts Heart Centre, St. Bartholomew’s Hospital, London, UK
| | - Haran Burri
- Cardiology Department, Cardiac Pacing Unit, University Hospital of Geneva, Geneva, Switzerland
| | | | - Grégoire Massoullié
- CHU Clermont-Ferrand, Université de Clermont-Ferrand, Clermont-Ferrand, France
| | - Jose Luis Merino
- Arrhythmia-Robotic Electrophysiology Unit, La Paz University Hospital, IdiPAZ, Universidad Autonoma, Madrid, Spain
| | - Maria F Paton
- Leeds Institute of Cardiovascular and Metabolic Medicine,University of Leeds, Leeds, UK
| | - Andreu Porta-Sánchez
- Institut Clinic Cardiovascular, Hospital Clínic, Universitat de Barcelona, Catalonia, Spain
| | - Philipp Sommer
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Daniel Steven
- Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | | | - Hikmet Yorgun
- Faculty of Medicine, Department of Cardiology, Hacettepe University, Ankara, Turkey
| |
Collapse
|
2
|
Funasako M, Hála P, Janotka M, Šorf J, Machová L, Petrů J, Chovanec M, Škoda J, Šedivá L, Šimon J, Dujka L, Reddy VY, Neužil P. Transcatheter non-acute retrieval of the tine-based leadless ventricular pacemaker. Europace 2024; 26:euae256. [PMID: 39374848 PMCID: PMC11503947 DOI: 10.1093/europace/euae256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Revised: 07/26/2024] [Accepted: 09/03/2024] [Indexed: 10/09/2024] Open
Abstract
AIMS We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios. METHODS AND RESULTS We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 min, and the fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications. CONCLUSION A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.
Collapse
Affiliation(s)
- Moritoshi Funasako
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Pavel Hála
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Marek Janotka
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | | | - Lucie Machová
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Jan Petrů
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Milan Chovanec
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Jan Škoda
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Lucie Šedivá
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Jaroslav Šimon
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Libor Dujka
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| | - Vivek Y Reddy
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
- Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Petr Neužil
- Cardiology Department, Na Homolce Hospital, Roentgenova 37/2, 15030 Prague, Czech Republic
| |
Collapse
|
3
|
Özkartal T, Bergonti M, Caputo ML, Costantino J, Klersy C, Conte G. High lead-related complication rate with MicroPort Vega active fixation pacing leads. Europace 2024; 26:euae242. [PMID: 39288313 PMCID: PMC11448328 DOI: 10.1093/europace/euae242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 08/22/2024] [Accepted: 09/16/2024] [Indexed: 09/19/2024] Open
Affiliation(s)
- Tardu Özkartal
- Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Via Tesserete 48, Lugano, Switzerland
| | - Marco Bergonti
- Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Via Tesserete 48, Lugano, Switzerland
| | - Maria Luce Caputo
- Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Via Tesserete 48, Lugano, Switzerland
- Faculty of Biomedical Sciences, Università della Svizzera italiana, Lugano, Switzerland
| | - Jacopo Costantino
- Clinical, Anestesiologic and Cardiovascular Sciences, La Sapienza University of Rome, Rome, Italy
| | - Catherine Klersy
- Unit Biostatistics and Clinical Trial Center, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
| | - Giulio Conte
- Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Via Tesserete 48, Lugano, Switzerland
- Faculty of Biomedical Sciences, Università della Svizzera italiana, Lugano, Switzerland
| |
Collapse
|
4
|
Mascheroni J, Stockburger M, Patwala A, Mont L, Rao A, Retzlaff H, Garweg C, Gallagher AG, Verbelen T. Surgical skill simulation training to proficiency reduces procedural errors among novice cardiac device implanters: a randomized study. Europace 2024; 26:euae229. [PMID: 39257213 PMCID: PMC11412769 DOI: 10.1093/europace/euae229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2024] [Revised: 08/15/2024] [Accepted: 09/01/2024] [Indexed: 09/12/2024] Open
Abstract
AIMS In cardiac device implantation, having both surgical skills and ability to manipulate catheter/lead/wire is crucial. Few cardiologists, however, receive formal surgical training prior to implanting. Skills are mostly acquired directly on-the-job and surgical technique varies across institutions; suboptimal approaches may increase complications. We investigated how novel proficiency-based progression (PBP) simulation training impacts the surgical quality of implantations, compared to traditional simulation (SIM) training. METHODS AND RESULTS In this international prospective study, novice implanters were randomized (blinded) 1:1 to participate in a simulation-based procedure training curriculum, with proficiency demonstration requirements for advancing (PBP approach) or without (SIM). Ultimately, trainees performed the surgical tasks of an implant on a porcine tissue that was video-recorded and then scored by two independent assessors (blinded to group), using previously validated performance metrics. Primary outcomes were the number of procedural Steps Completed, Critical Errors, Errors (non-critical), and All Errors Combined. Thirty novice implanters from 10 countries participated. Baseline experiences were similar between groups. Compared to SIM-trained, the PBP-trained group completed on average 11% more procedural Steps (P < 0.001) and made 61.2% fewer Critical Errors (P < 0.001), 57.1% fewer Errors (P = 0.140), and 60.7% fewer All Errors Combined (P = 0.001); 11/15 (73%) PBP trainees demonstrated the predefined target performance level vs. 3/15 SIM trainees (20%) in the video-recorded performance. CONCLUSION Proficiency-based progression training produces superior objectively assessed novice operators' surgical performance in device implantation compared with traditional (simulation) training. Systematic PBP incorporation into formal academic surgical skills training is recommended before in vivo device practice. Future studies will quantify PBP training's effect on surgery-related device complications.
Collapse
Affiliation(s)
- Jorio Mascheroni
- Department of Cardiovascular Sciences, KU Leuven, Herestraat 49, 3000 Leuven, Belgium
- Department of Cardiac Rhythm Management Training & Education, Medtronic International Trading Sàrl, Route du Molliau 31, 1131 Tolochenaz, Switzerland
| | - Martin Stockburger
- Department of Cardiology and Internal Medicine, Havelland Kliniken, Ketziner Straße 21, 14641 Nauen, Germany
- Institute of Medical Sociology and Rehabilitation Science, Charité—Universitaetsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Ashish Patwala
- Department of Cardiology, University Hospital of North Midlands, Newcastle Road, ST4 6QG Stoke-on-Trent, UK
| | - Lluís Mont
- Department of Cardiology, Hospital Clinic, Universitat de Barcelona, C/Villarroel 170, 08036 Barcelona, Catalonia, Spain
- Institut d’Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), c/Rosselló 149, 08036 Barcelona, Catalonia, Spain
- Centro de Investigación Biomédica en Red Cardiovascular (CIBERCV), Av. Monforte de Lemos 3-5, 28029 Madrid, Spain
| | - Archana Rao
- Department of Cardiology, Liverpool Heart and Chest Hospital, Thomas Drive, L14 3PE Liverpool, UK
| | - Hartwig Retzlaff
- Training Concept Consulting, Alpenstrasse 14a, D-82194 Groebenzell, Germany
| | - Christophe Garweg
- Department of Cardiovascular Sciences, KU Leuven, Herestraat 49, 3000 Leuven, Belgium
- Department of Cardiology, UZ Leuven, Herestraat 49, 3000 Leuven, Belgium
| | - Anthony G Gallagher
- Orsi Academy, Proefhoevestraat 12, 9090 Melle, Belgium
- Faculty of Medicine, KU Leuven, Herestraat 49, 3000 Leuven, Belgium
- School of Medicine, Faculty of Life and Health Sciences, Ulster University, Magee Campus, Northland Rd, BT48 7JL Londonderry, UK
| | - Tom Verbelen
- Department of Cardiovascular Sciences, KU Leuven, Herestraat 49, 3000 Leuven, Belgium
- Department of Cardiac Surgery, UZ Leuven, Herestraat 49, 3000 Leuven, Belgium
| |
Collapse
|
5
|
Bodin A, Texier I, Bisson A, Pierre B, Herbert J, Jacobs M, Nasarre M, Bernard A, Fauchier L. Dual-chamber vs. single-chamber pacemaker in patients in sinus rhythm with an atrioventricular block: a nationwide cohort study. Europace 2024; 26:euae238. [PMID: 39271128 PMCID: PMC11424992 DOI: 10.1093/europace/euae238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2024] [Revised: 08/31/2024] [Accepted: 09/09/2024] [Indexed: 09/15/2024] Open
Abstract
AIMS In complete atrioventricular block (AVB) with underlying sinus rhythm, it is recommended to implant a dual-chamber pacemaker rather than a single-chamber pacemaker. However, no large-scale study has been able to demonstrate the superiority of this choice on hard clinical criteria such as morbimortality. METHODS AND RESULTS This retrospective observational study included all patients who received a primary pacemaker implantation in the indication of complete AVB with underlying sinus rhythm in France, based on the national administrative database between January 2013 and December 2022. After propensity score matching, we obtained two groups containing 19 219 patients each. The incidence of all-cause mortality was 9.22%/year for the dual-chamber pacemaker group, compared with 11.48%/year for the single-chamber pacemaker group (hazard ratio (HR) 0.807, P < 0.0001]. Similarly, there was a lower incidence of cardiovascular mortality (HR 0.766, P < 0.0001), heart failure (HR 0.908, P < 0.0001), atrial fibrillation (HR 0.778, P < 0.0001), and ischaemic stroke (HR 0.873, P = 0.008) in the dual-chamber pacemaker group than in the single-chamber pacemaker group. Regarding re-interventions and complications, there were fewer upgrades (addition of atrial lead or left ventricular lead) in the dual-chamber group (HR 0.210, P < 0.0001), but more haematomas (HR 1.179, P = 0.006) and lead repositioning (HR 1.123, P = 0.04). CONCLUSION In the indication of complete AVB with underlying sinus rhythm, our results are consistent with current recommendations to prefer implantation of a dual-chamber pacemaker rather than a single-chamber pacemaker for these patients. Implantation of a dual-chamber pacemaker is associated with a lower risk of mortality, heart failure, atrial fibrillation, and stroke during follow-up.
Collapse
Affiliation(s)
- Alexandre Bodin
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Ivann Texier
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Arnaud Bisson
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Bertrand Pierre
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Julien Herbert
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
- Service d'Information Médicale, D'épidémiologie et d'Économie de la Santé, Centre Hospitalier Universitaire et EA7505, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Mathieu Jacobs
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Mathieu Nasarre
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Anne Bernard
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| | - Laurent Fauchier
- Service de Cardiologie, Centre Hospitalier Universitaire Trousseau, Faculté de Médecine, Université François Rabelais, 37000 Tours, France
| |
Collapse
|
6
|
Molitor N, Saleem-Talib S, Ramanna H, Hofer D, Breitenstein A, Steffel J. Leadless pacemaker implantation via the internal jugular vein. Europace 2024; 26:euae199. [PMID: 39051875 PMCID: PMC11304476 DOI: 10.1093/europace/euae199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Accepted: 07/16/2024] [Indexed: 07/27/2024] Open
Abstract
AIMS Leadless pacemaker therapy was introduced to overcome lead- and pocket-related complications in conventional transvenous pacemaker systems. Implantation via the femoral vein, however, may not always be feasible. The aim of this study was to evaluate leadless pacemaker implantation using a jugular vein approach and compare it to the standard implantation via the femoral vein. METHODS AND RESULTS The records of the first consecutive 100 patients undergoing Micra™ leadless pacemaker implantation via the right internal jugular vein from two centres were included in this study. Peri-procedural safety and efficacy of the jugular approach were compared to the first 100 patients using a femoral implantation approach at the University Hospital Zurich. One hundred patients underwent successful implantation of a leadless pacemaker via the internal jugular vein (mean age, 81.18 ± 8.29, 60% males). Mean procedure time was 35.63 ± 10.29 min with a mean fluoroscopy time of 4.66 ± 5.16 min. The device was positioned at the inferior septum in 25 patients, at the high septum in 24 patients, and mid-septum in 51 patients. The mean pacing threshold was 0.56 ± 0.35 V at 0.24 ms pulse width with a sensed amplitude of 10.0 ± 4.4 mV. At follow-up, electrical parameters remained stable in all patients. Compared with femoral implantation, patients undergoing the jugular approach were of similar age and had similar comorbidities. Mean procedure (48.9 ± 21.0 min) and fluoroscopy times (7.7 ± 7.8 min, both P < 0.01) were shorter compared to the femoral approach. Electrical parameters were similar between the two approaches. There were only two complications during jugular veinous implantations (1 pericardial effusion and 1 dislocation), compared to 16 complications using the femoral approach (1 pericardial effusion, 2 femoral artery injuries, and 13 major groin haematomas). CONCLUSION The jugular approach may represent a safe and efficient alternative to femoral implantation of the Micra leadless pacemaker.
Collapse
Affiliation(s)
- Nadine Molitor
- Department of Cardiology, University Heart Center, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | | | - Hemanth Ramanna
- Department of Cardiology, Haga Teaching Hospital, The Hague, The Netherlands
- The Hague University of Applied Sciences, The Hague, The Netherlands
| | - Daniel Hofer
- Department of Cardiology, Triemlispial, Zurich, Switzerland
| | - Alexander Breitenstein
- Department of Cardiology, University Heart Center, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | - Jan Steffel
- HeartClinic, Hirslanden Clinic, Zurich, Switzerland
| |
Collapse
|
7
|
Mei DA, Imberti JF, Vitolo M, Bonini N, Serafini K, Mantovani M, Tartaglia E, Birtolo C, Zuin M, Bertini M, Boriani G. Systematic review and meta-analysis on the impact on outcomes of device algorithms for minimizing right ventricular pacing. Europace 2024; 26:euae212. [PMID: 39120658 PMCID: PMC11346371 DOI: 10.1093/europace/euae212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 07/09/2024] [Accepted: 08/05/2024] [Indexed: 08/10/2024] Open
Abstract
AIMS Physiological activation of the heart using algorithms to minimize right ventricular pacing (RVPm) may be an effective strategy to reduce adverse events in patients requiring anti-bradycardia therapies. This systematic review and meta-analysis aimed to evaluate current evidence on clinical outcomes for patients treated with RVPm algorithms compared to dual-chamber pacing (DDD). METHODS AND RESULTS We conducted a systematic search of the PubMed database. The predefined endpoints were the occurrence of persistent/permanent atrial fibrillation (PerAF), cardiovascular (CV) hospitalization, all-cause death, and adverse symptoms. We also aimed to explore the differential effects of algorithms in studies enrolling a high percentage of atrioventricular block (AVB) patients. Eight studies (7229 patients) were included in the analysis. Compared to DDD pacing, patients using RVPm algorithms showed a lower risk of PerAF [odds ratio (OR) 0.74, 95% confidence interval (CI) 0.57-0.97] and CV hospitalization (OR 0.77, 95% CI 0.61-0.97). No significant difference was found for all-cause death (OR 1.01, 95% CI 0.78-1.30) or adverse symptoms (OR 1.03, 95% CI 0.81-1.29). No significant interaction was found between the use of the RVPm strategy and studies enrolling a high percentage of AVB patients. The pooled mean RVP percentage for RVPm algorithms was 7.96% (95% CI 3.13-20.25), as compared with 45.11% (95% CI 26.64-76.38) of DDD pacing. CONCLUSION Algorithms for RVPm may be effective in reducing the risk of PerAF and CV hospitalization in patients requiring anti-bradycardia therapies, without an increased risk of adverse symptoms. These results are also consistent for studies enrolling a high percentage of AVB patients.
Collapse
Affiliation(s)
- Davide Antonio Mei
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Jacopo Francesco Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Niccolò Bonini
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Kevin Serafini
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
| | - Marta Mantovani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
| | - Enrico Tartaglia
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
| | - Chiara Birtolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
| | - Marco Zuin
- Cardiology Unit, Department of Translational Medicine Sant’Anna University Hospital, University of Ferrara, Ferrara, Italy
| | - Matteo Bertini
- Cardiology Unit, Department of Translational Medicine Sant’Anna University Hospital, University of Ferrara, Ferrara, Italy
| | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo 71, Modena 41121, Italy
| |
Collapse
|
8
|
Mazza A, Bendini MG, Leggio M, Imberti JF, Valsecchi S, Boriani G. Clinical significance and prognostic value of right bundle branch block in permanent pacemaker patients. J Cardiovasc Med (Hagerstown) 2024; 25:551-558. [PMID: 38809231 DOI: 10.2459/jcm.0000000000001641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2024]
Abstract
AIMS In patients undergoing pacemaker implantation with no prior history of heart failure (HF), the presence of left bundle branch block (LBBB) has been identified as an independent predictor of HF-related death or hospitalization, while the prognostic significance of right bundle branch block (RBBB) remains uncertain. We aimed to assess the long-term risk of all-cause mortality in patients with a standard indication for permanent pacing and normal or moderately depressed left ventricular function when RBBB is detected at the time of implantation. METHODS We retrospectively enrolled 1348 consecutive patients who had undergone single- or dual-chamber pacemaker implantation at the study center, from January 1990 to December 2022. Patients with a left ventricular ejection fraction ≤35% or a prior diagnosis of HF were excluded. RESULTS The baseline 12-lead electrocardiogram revealed an RBBB in 241 (18%) and an LBBB in 98 (7%) patients. During a median follow-up of 65 [25th-75th percentile: 32-117] months, 704 (52%) patients died. The combined endpoint of cardiovascular death or HF hospitalization was reached by 173 (13%) patients. On multivariate analysis, RBBB was confirmed as an independent predictor of death [hazard ratio, 1.33; 95% confidence interval (CI), 1.09-1.63; P = 0.005]. However, when considering the combined endpoint of cardiovascular death and HF hospitalization, this endpoint was independently associated with LBBB (hazard ratio, 2.13; 95% CI, 1.38-3.29; P < 0.001), but not with RBBB. CONCLUSION In patients with standard pacemaker indications and normal or moderately depressed left ventricular function, the presence of basal RBBB was an independent predictor of mortality. However, it was not associated with the combined endpoint of cardiovascular death and HF hospitalization.
Collapse
Affiliation(s)
- Andrea Mazza
- Cardiology Division, S. Maria della Stella Hospital, Orvieto
| | | | - Massimo Leggio
- Clinica Salus Infirmorum, S. Filippo Neri Hospital, Rome
| | - Jacopo F Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia
| | | | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena
| |
Collapse
|
9
|
Alaoui-Ismaili Z, Klein A, Moeller JE, Bo Lindhardt T, Hassager C. Cardiac tamponade due to right coronary artery perforation following pacemaker implantation: a case report. Eur Heart J Case Rep 2024; 8:ytae343. [PMID: 39071535 PMCID: PMC11276959 DOI: 10.1093/ehjcr/ytae343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 02/21/2024] [Accepted: 07/03/2024] [Indexed: 07/30/2024]
Abstract
Background Cardiac tamponade due to perforation of a cardiac chamber is a rare complication occurring in only 0.3% of patients undergoing permanent pacemaker (PM) implantation. Notably, perforation of the right coronary artery (RCA) following permanent PM implantation has only been reported twice in the literature. We report a rare case of RCA perforation leading to life-threatening cardiac tamponade with symptom onset 4 days after PM implantation. Case summary A 75-year-old woman underwent permanent PM implantation without any difficulties in placing pacemaker leads and with good thresholds. Four days later, the patient was readmitted in a state of shock due to cardiac tamponade. A blood gas analysis on the bloody pericardial effusion raised suspicion of ongoing arterial bleeding. A CT scan ruled out aortic dissection; instead, the source of bleeding was identified as a perforation in the RCA, which was managed surgically. Discussion This case highlights the necessity of coronary artery perforation being among the differential diagnoses of cardiac tamponade after PM implantation, and it stresses the usefulness of performing a blood gas analysis on the bloody pericardial effusion.
Collapse
Affiliation(s)
- Zakaria Alaoui-Ismaili
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
| | - Anika Klein
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
| | - Jacob Eifer Moeller
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | | | - Christian Hassager
- Department of Cardiology, Copenhagen University Hospital—Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen Ø, Denmark
| |
Collapse
|
10
|
Malikides O, Simantirakis E, Zacharis E, Fragkiadakis K, Kochiadakis G, Marketou M. Cardiac Remodeling and Ventricular Pacing: From Genes to Mechanics. Genes (Basel) 2024; 15:671. [PMID: 38927607 PMCID: PMC11203142 DOI: 10.3390/genes15060671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Revised: 05/17/2024] [Accepted: 05/21/2024] [Indexed: 06/28/2024] Open
Abstract
Cardiac remodeling and ventricular pacing represent intertwined phenomena with profound implications for cardiovascular health and therapeutic interventions. This review explores the intricate relationship between cardiac remodeling and ventricular pacing, spanning from the molecular underpinnings to biomechanical alterations. Beginning with an examination of genetic predispositions and cellular signaling pathways, we delve into the mechanisms driving myocardial structural changes and electrical remodeling in response to pacing stimuli. Insights into the dynamic interplay between pacing strategies and adaptive or maladaptive remodeling processes are synthesized, shedding light on the clinical implications for patients with various cardiovascular pathologies. By bridging the gap between basic science discoveries and clinical translation, this review aims to provide a comprehensive understanding of cardiac remodeling in the context of ventricular pacing, paving the way for future advancements in cardiovascular care.
Collapse
Affiliation(s)
- Onoufrios Malikides
- Department of Cardiology, University General Hospital of Heraklion, 71003 Heraklion, Greece; (E.S.); (E.Z.); (K.F.); (G.K.); (M.M.)
| | - Emmanouel Simantirakis
- Department of Cardiology, University General Hospital of Heraklion, 71003 Heraklion, Greece; (E.S.); (E.Z.); (K.F.); (G.K.); (M.M.)
- Medical School, University of Crete, 71003 Heraklion, Greece
| | - Evangelos Zacharis
- Department of Cardiology, University General Hospital of Heraklion, 71003 Heraklion, Greece; (E.S.); (E.Z.); (K.F.); (G.K.); (M.M.)
- Medical School, University of Crete, 71003 Heraklion, Greece
| | - Konstantinos Fragkiadakis
- Department of Cardiology, University General Hospital of Heraklion, 71003 Heraklion, Greece; (E.S.); (E.Z.); (K.F.); (G.K.); (M.M.)
- Medical School, University of Crete, 71003 Heraklion, Greece
| | - George Kochiadakis
- Department of Cardiology, University General Hospital of Heraklion, 71003 Heraklion, Greece; (E.S.); (E.Z.); (K.F.); (G.K.); (M.M.)
- Medical School, University of Crete, 71003 Heraklion, Greece
| | - Maria Marketou
- Department of Cardiology, University General Hospital of Heraklion, 71003 Heraklion, Greece; (E.S.); (E.Z.); (K.F.); (G.K.); (M.M.)
- Medical School, University of Crete, 71003 Heraklion, Greece
| |
Collapse
|
11
|
Xu F, Meng L, Lin H, Xu W, Guo H, Peng F. Systematic review of leadless pacemaker. Acta Cardiol 2024; 79:284-294. [PMID: 37961771 DOI: 10.1080/00015385.2023.2276537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 10/20/2023] [Indexed: 11/15/2023]
Abstract
Conventional pacing systems consist of a pacemaker and one or more leads threaded from the device pocket through veins into the heart conducting the pacing therapy to the desired pacing site. Although these devices are effective, approximately one in eight patients treated with these traditional pacing systems experiences a complication attributed to the pacemaker pocket or leads. With the technological advances in electronics, leadless pacemakers that small enough to implant within the heart were introduced. Leadless pacemakers have been developed to overcome many of the challenges of transvenous pacing including complications related to leads or pacemaker pockets. This review aims to provide an overview of advantages of leadless pacemaker, complications and limitations of leadless pacemaker, leadless pacemaker candidate, and future directions of this promising technology.
Collapse
Affiliation(s)
- Fukang Xu
- Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing, China
| | - Liping Meng
- Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing, China
| | - Hui Lin
- Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing, China
| | - Weiyuan Xu
- Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing, China
| | - Hangyuan Guo
- Shaoxing Wen li Medical College, Shaoxing, China
| | - Fang Peng
- Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing, China
| |
Collapse
|
12
|
Auricchio A. Editorial. Europace 2023; 26:euae008. [PMID: 38207128 PMCID: PMC10803038 DOI: 10.1093/europace/euae008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Indexed: 01/13/2024] Open
Affiliation(s)
- Angelo Auricchio
- Istituto Cardiocentro Ticino - Ente Ospedaliero Cantonale, Via Tesserete 48, 6900 Lugano, Switzerland
| |
Collapse
|
13
|
Wang Y, Huang H, Sun J, Shi J, Liu X, Feng L. Tissue-induced winding of permanent pacemaker passive-fixation leads. Quant Imaging Med Surg 2023; 13:8799-8802. [PMID: 38106301 PMCID: PMC10722079 DOI: 10.21037/qims-23-639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 09/11/2023] [Indexed: 12/19/2023]
Affiliation(s)
- Yu Wang
- Department of Cardiology, Shidong Hospital, Yangpu District, Shidong Hospital Affiliated to University of Shanghai for Science and Technology, Shanghai, China
| | - Hongman Huang
- Department of Cardiology, Shidong Hospital, Yangpu District, Shidong Hospital Affiliated to University of Shanghai for Science and Technology, Shanghai, China
| | - Jianhua Sun
- Department of Cardiology, Shidong Hospital, Yangpu District, Shidong Hospital Affiliated to University of Shanghai for Science and Technology, Shanghai, China
| | - Jun Shi
- Department of Cardiology, Shidong Hospital, Yangpu District, Shidong Hospital Affiliated to University of Shanghai for Science and Technology, Shanghai, China
| | - Xinbing Liu
- Department of Cardiology, Shidong Hospital, Yangpu District, Shidong Hospital Affiliated to University of Shanghai for Science and Technology, Shanghai, China
| | - Liuliu Feng
- Department of Cardiology, Shidong Hospital, Yangpu District, Shidong Hospital Affiliated to University of Shanghai for Science and Technology, Shanghai, China
| |
Collapse
|
14
|
Backhoff D, Müller MJ, Wilberg Y, Eildermann K, Paul T, Zenker D, Krause U. Leadless epicardial pacing at the left ventricular apex: an animal study. Europace 2023; 25:euad303. [PMID: 37906433 PMCID: PMC10616611 DOI: 10.1093/europace/euad303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 09/29/2023] [Indexed: 11/02/2023] Open
Abstract
AIMS State-of-the-art pacemaker implantation technique in infants and small children consists of pace/sense electrodes attached to the epicardium and a pulse generator in the abdominal wall with a significant rate of dysfunction during growth, mostly attributable to lead failure. In order to overcome lead-related problems, feasibility of epicardial implantation of a leadless pacemaker at the left ventricular apex in a growing animal model was studied. METHODS AND RESULTS Ten lambs (median body weight 26.8 kg) underwent epicardial implantation of a Micra transcatheter pacing system (TPS) pacemaker (Medtronic Inc., Minneapolis, USA). Using a subxyphoid access, the Micra was introduced through a short, thick-walled tube to increase tissue contact and to prevent tilting from the epicardial surface. The Micra's proprietary delivery system was firmly pressed against the heart, while the Micra was pushed forward out of the sheath allowing the tines to stick into the left ventricular apical epimyocardium. Pacemakers were programmed to VVI 30/min mode. Pacemaker function and integrity was followed for 4 months after implantation. After implantation, median intrinsic R-wave amplitude was 5 mV [interquartile range (IQR) 2.8-7.5], and median pacing impedance was 2235 Ω (IQR 1725-2500), while the median pacing threshold was 2.13 V (IQR 1.25-2.9) at 0.24 ms. During follow-up, 6/10 animals had a significant increase in pacing threshold with loss of capture at maximum output at 0.24 ms in 2/10 animals. After 4 months, median R-wave amplitude had dropped to 2.25 mV (IQR 1.2-3.6), median pacing impedance had decreased to 595 Ω (IQR 575-645), and median pacing threshold had increased to 3.3 V (IQR 1.8-4.5) at 0.24 ms. Explantation of one device revealed deep penetration of the Micra device into the myocardium. CONCLUSION Short-term results after epicardial implantation of the Micra TPS at the left ventricular apex in lambs were satisfying. During mid-term follow-up, however, pacing thresholds increased, resulting in loss of capture in 2/10 animals. Penetration of one device into the myocardium was of concern. The concept of epicardial leadless pacing seems very attractive, and the current shape of the Micra TPS makes the device unsuitable for epicardial placement in growing organisms.
Collapse
Affiliation(s)
- David Backhoff
- Pediatric Heart Center, Justus-Liebig University Giessen, Feulgenstrasse 10-12, 35385 Gießen, Germany
- Department of Pediatric Cardiology, Intensive Care Medicine and Neonatology, University Medical Center, Georg-August-University Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
| | - Matthias J Müller
- Department of Pediatric Cardiology, Intensive Care Medicine and Neonatology, University Medical Center, Georg-August-University Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
| | - Yannic Wilberg
- Department of Pediatric Cardiology, Intensive Care Medicine and Neonatology, University Medical Center, Georg-August-University Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
| | - Katja Eildermann
- Department of Pediatric Cardiology, Intensive Care Medicine and Neonatology, University Medical Center, Georg-August-University Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
| | - Thomas Paul
- Department of Pediatric Cardiology, Intensive Care Medicine and Neonatology, University Medical Center, Georg-August-University Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
| | - Dieter Zenker
- Department of Thoracic and Cardiac Surgery, University Medical Center, Georg-August-University Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
| | - Ulrich Krause
- Department of Pediatric Cardiology, Intensive Care Medicine and Neonatology, University Medical Center, Georg-August-University Göttingen, Robert-Koch Str. 40, 37075 Göttingen, Germany
| |
Collapse
|
15
|
Boriani G, Imberti JF, Leyva F, Casado-Arroyo R, Chun J, Braunschweig F, Zylla MM, Duncker D, Farkowski MM, Pürerfellner H, Merino JL. Length of hospital stay for elective electrophysiological procedures: a survey from the European Heart Rhythm Association. Europace 2023; 25:euad297. [PMID: 37789664 PMCID: PMC10563655 DOI: 10.1093/europace/euad297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 09/24/2023] [Indexed: 10/05/2023] Open
Abstract
AIMS Electrophysiological (EP) operations that have traditionally involved long hospital lengths of stay (LOS) are now being undertaken as day case procedures. The coronavirus disease-19 pandemic served as an impetus for many centres to shorten LOS for EP procedures. This survey explores LOS for elective EP procedures in the modern era. METHODS AND RESULTS An online survey consisting of 27 multiple-choice questions was completed by 245 respondents from 35 countries. With respect to de novo cardiac implantable electronic device (CIED) implantations, day case procedures were reported for 79.5% of implantable loop recorders, 13.3% of pacemakers (PMs), 10.4% of implantable cardioverter defibrillators (ICDs), and 10.2% of cardiac resynchronization therapy (CRT) devices. With respect to CIED generator replacements, day case procedures were reported for 61.7% of PMs, 49.2% of ICDs, and 48.2% of CRT devices. With regard to ablations, day case procedures were reported for 5.7% of atrial fibrillation (AF) ablations, 10.7% of left-sided ablations, and 17.5% of right-sided ablations. A LOS ≥ 2 days for CIED implantation was reported for 47.7% of PM, 54.5% of ICDs, and 56.9% of CRT devices and for 54.5% of AF ablations, 42.2% of right-sided ablations, and 46.1% of left-sided ablations. Reimbursement (43-56%) and bed availability (20-47%) were reported to have no consistent impact on the organization of elective procedures. CONCLUSION There is a wide variation in the LOS for elective EP procedures. The LOS for some procedures appears disproportionate to their complexity. Neither reimbursement nor bed availability consistently influenced LOS.
Collapse
Affiliation(s)
- Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo, 71, Modena 41124, Italy
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
| | - Jacopo F Imberti
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Via del Pozzo, 71, Modena 41124, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| | - Francisco Leyva
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Cardiology, Aston Medical Research Institute, Aston Medical School, Aston University, Aston Triangle, Birmingham B4 7ET, UK
| | - Ruben Casado-Arroyo
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Cardiology, H.U.B.-Hôpital Erasme, Université Libre de Bruxelles, Brussels 1070, Belgium
| | - Julian Chun
- Medizinische Klinik III, CCB am Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
| | - Frieder Braunschweig
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Medicine; Solna, Karolinska Institutet and ME Cardiology, Karolinska University Hospital, Norrbacka S1:02, Eugeniavagen 27, Stockholm 171 77, Sweden
| | - Maura M Zylla
- mHealth and Health Economics and PROM Committee of EHRA (European Heart Rhythm Association)
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
| | - David Duncker
- Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Hannover 30625, Germany
| | - Michał M Farkowski
- Department of Cardiology, Ministry of Interior and Administration National Medical Institute, Warsaw, Poland
| | - Helmut Pürerfellner
- Ordensklinikum Linz Elisabethinen, Interne II/Kardiologie und Interne Intensivmedizin, Fadingerstraße 1, 4020 Linz, Austria
| | - José L Merino
- Arrhythmia-Robotic Electrophysiology Unit, La Paz University Hospital, IdiPAZ, Universidad Autonoma, Madrid, Spain
| |
Collapse
|
16
|
Chaudhary MH, Dev S, Kumari A, Kanwal K, Jadav DN, Rasool S, Tayyab Saleem M, Bhagat R, Prachi F, Puri P, Kashif M, Varrassi G, Khatri M, Kumar S, Mohamad T. Holistic Approaches to Arrhythmia Management: Combining Medication, Ablation, and Device Interventions. Cureus 2023; 15:e45958. [PMID: 37900386 PMCID: PMC10600027 DOI: 10.7759/cureus.45958] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 09/25/2023] [Indexed: 10/31/2023] Open
Abstract
This narrative review investigates the severe health issue of arrhythmias, which affects millions of people worldwide. A multifaceted strategy incorporating medicine, catheter ablation, and advanced device interventions is necessary to manage these disorders effectively. Medication is the cornerstone, and as antiarrhythmic medications develop, their efficacy and side effects are reduced. Success depends on having individualized treatment strategies that consider patient profiles and arrhythmia type. Catheter ablation, a minimally invasive surgery that targets and removes faulty heart electrical circuits, has become a potent therapy when drugs are ineffective. Technological developments, including high-resolution mapping systems and customized catheters, improve precision. Pacemakers and implantable cardioverter-defibrillators (ICDs) are two examples of implantable cardiac devices essential to managing all types of arrhythmias. Pacemakers provide a regular heartbeat when the body's natural pacing mechanism fails. At the same time, ICDs, with cutting-edge algorithms, can identify and stop life-threatening arrhythmias and offer high-risk patients vital protection. As device technology advances, smaller, more durable devices become available, improving patient comfort and lowering the need for replacements. The seamless fusion of these three strategies is where holistic arrhythmia management shines. Even for difficult instances, customized combination therapy combining medicine, ablation, and device interventions offers complete solutions. Healthcare providers must collaborate for this integrated strategy to deliver personalized, efficient, and holistic care. In conclusion, the management of arrhythmias has developed into a dynamic, synergistic discipline where drugs, catheter ablation, and devices all work in concert to deliver comprehensive care. For those with arrhythmias, a patient-centered strategy that considers their particular patient features and best integrates different modalities can significantly enhance their quality of life. The effectiveness and accessibility of holistic arrhythmia management could be further improved because of ongoing developments in these fields, which is encouraging for patients and medical professionals.
Collapse
Affiliation(s)
| | - Shah Dev
- Medicine, Jinnah Sindh Medical University, Karachi, PAK
| | - Ankeeta Kumari
- Medicine, Liaquat University of Medical and Health Sciences, Jamshoro, PAK
| | - Kainat Kanwal
- Medicine, Khawaja Muhammad Safdar Medical College, Sialkot, PAK
| | | | - Sohaib Rasool
- Medicine, Bakhtawar Amin Medical and Dental College, Multan, PAK
| | | | - Ridhi Bhagat
- Internal Medicine, Teerthanker Mahaveer Medical College and Reseach Center, Moradabad , IND
| | - Fnu Prachi
- Medicine, Guru Teg Bahadur Hospital, Delhi, IND
| | - Piyush Puri
- Internal Medicine, Adesh Institute of Medical Science and Research, Bathinda, IND
| | - Maham Kashif
- Medicine, Khawaja Muhammad Safdar Medical College, Sialkot, PAK
| | | | - Mahima Khatri
- Medicine and Surgery, Dow University of Health Sciences, Karachi, PAK
| | - Satesh Kumar
- Medicine and Surgery, Shaheed Mohtarma Benazir Bhutto Medical College, Karachi, PAK
| | - Tamam Mohamad
- Cardiovascular Medicine, Wayne State University, Detroit, USA
| |
Collapse
|