Uzun DD, Salatzki J, Xynogalos P, Frey N, Debus J, Lang K. Effects of Ionizing Radiation on Cardiac Implantable Electronic Devices (CIEDs) in Patients with Esophageal Cancer Undergoing Radiotherapy: A Pilot Study. Cancers (Basel) 2024; 16:555. [PMID: 38339306 PMCID: PMC10854512 DOI: 10.3390/cancers16030555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/24/2024] [Accepted: 01/25/2024] [Indexed: 02/12/2024] Open
Abstract
(1) Background: The prevalence of cancer patients relying on cardiac implantable electronic device (CIED) is steadily rising. The aim of this study was to evaluate RT-related malfunctions of CIEDs. (2) Methods: We retrospectively analyze sixteen patients with esophageal cancer who were treated with radiotherapy between 2012 and 2022 at the University Hospital Heidelberg. All patients underwent systemic evaluation including pre-therapeutic cardiological examinations of the CIED functionality and after every single irradiation. (3) Results: Sixteen patients, predominantly male (14) with a mean age of 77 (range: 56-85) years were enrolled. All patients received 28 fractions of radiotherapy with a cumulative total dose 58.8 Gy. The mean maximum dose at the CIEDs was 1.8 Gy. Following radiotherapy and during the one-year post-radiation follow-up period, there were no registered events associated with the treatment in this evaluation. (4) Conclusion: The study did not observe any severe CIED malfunctions following each radiation fraction or after completion of RT. Strict selection of photon energy and alignment with manufacturer-recommended dose limits appear to be important. Our study showed no major differences in the measured values of the pacing threshold, sensing threshold and lead impedance after RT.
Collapse
Affiliation(s)
- Davut D. Uzun
- Department of Anesthesiology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- Heidelberg Center for Heart Rhythm Disorders (HCR), 69120 Heidelberg, Germany; (J.S.); (P.X.); (N.F.)
- Department of Cardiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Janek Salatzki
- Heidelberg Center for Heart Rhythm Disorders (HCR), 69120 Heidelberg, Germany; (J.S.); (P.X.); (N.F.)
- Department of Cardiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Panagiotis Xynogalos
- Heidelberg Center for Heart Rhythm Disorders (HCR), 69120 Heidelberg, Germany; (J.S.); (P.X.); (N.F.)
- Department of Cardiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Norbert Frey
- Heidelberg Center for Heart Rhythm Disorders (HCR), 69120 Heidelberg, Germany; (J.S.); (P.X.); (N.F.)
- Department of Cardiology, Heidelberg University Hospital, 69120 Heidelberg, Germany
| | - Juergen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg University Hospital, 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- German Cancer Consortium (DKTK), Partner Site Heidelberg, 69120 Heidelberg, Germany
| | - Kristin Lang
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany;
- Heidelberg Institute of Radiation Oncology (HIRO), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), 69120 Heidelberg, Germany
| |
Collapse
|
2
|
van der Ree MH, Hoeksema WF, Luca A, Visser J, Balgobind BV, Zumbrink M, Spier R, Herrera-Siklody C, Lee J, Bates M, Daniel J, Peedell C, Boda-Heggemann J, Rudic B, Merten R, Dieleman EM, Rinaldi CA, Ahmad S, Whitaker J, Bhagirath P, Hatton MQ, Riley S, Grehn M, Schiappacasse L, Blanck O, Hohmann S, Pruvot E, Postema PG. Stereotactic arrhythmia radioablation: A multicenter pre-post intervention safety evaluation of the implantable cardioverter-defibrillator function. Radiother Oncol 2023; 189:109910. [PMID: 37709052 DOI: 10.1016/j.radonc.2023.109910] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 09/08/2023] [Accepted: 09/08/2023] [Indexed: 09/16/2023]
Abstract
BACKGROUND Stereotactic arrhythmia radioablation (STAR) appears to be beneficial in selected patients with therapy-refractory ventricular tachycardia (VT). However, high-dose radiotherapy used for STAR-treatment may affect functioning of the patients' implantable cardioverter defibrillator (ICD) by direct effects of radiation on ICD components or cardiac tissue. Currently, the effect of STAR on ICD functioning remains unknown. METHODS A retrospective pre-post multicenter study evaluating ICD functioning in the 12-month before and after STAR was performed. Patients with (non)ischemic cardiomyopathies with therapy-refractory VT and ICD who underwent STAR were included and the occurrence of ICD-related adverse events was collected. Evaluated ICD parameters included sensing, capture threshold and impedance. A linear mixed-effects model was used to investigate the association between STAR, radiotherapy dose and changes in lead parameters over time. RESULTS In total, 43 patients (88% male) were included in this study. All patients had an ICD with an additional right atrial lead in 34 (79%) and a ventricular lead in 17 (40%) patients. Median ICD-generator dose was 0.1 Gy and lead tip dose ranged from 0-32 Gy. In one patient (2%), a reset occurred during treatment, but otherwise, STAR and radiotherapy dose were not associated with clinically relevant alterations in ICD leads parameters. CONCLUSIONS STAR treatment did not result in major ICD malfunction. Only one radiotherapy related adverse event occurred during the study follow-up without patient harm. No clinically relevant alterations in ICD functioning were observed after STAR in any of the leads. With the reported doses STAR appears to be safe.
Collapse
Affiliation(s)
- Martijn H van der Ree
- Amsterdam UMC location University of Amsterdam, Department of Cardiology, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Cardiovascular Sciences, Heart Failure and Arrhythmias, Amsterdam, the Netherlands; Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Wiert F Hoeksema
- Amsterdam UMC location University of Amsterdam, Department of Cardiology, Meibergdreef 9, Amsterdam, the Netherlands
| | - Adrian Luca
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Jorrit Visser
- Amsterdam UMC location University of Amsterdam, Department of Radiation Oncology, Meibergdreef 9, Amsterdam, The Netherlands
| | - Brian V Balgobind
- Amsterdam UMC location University of Amsterdam, Department of Radiation Oncology, Meibergdreef 9, Amsterdam, The Netherlands
| | - Michiel Zumbrink
- Amsterdam UMC location University of Amsterdam, Department of Cardiology, Meibergdreef 9, Amsterdam, the Netherlands
| | - Raymond Spier
- Amsterdam UMC location University of Amsterdam, Department of Cardiology, Meibergdreef 9, Amsterdam, the Netherlands
| | | | - Justin Lee
- Department of Cardiology, Sheffield Teaching Hospitals NHS Trust, Sheffield, UK
| | - Matthew Bates
- Department of Cardiology, South Tees Hospitals NHS Foundation Trust, Middleborough, UK
| | - Jim Daniel
- Department of Radiation Oncology, South Tees Hospitals NHS Foundation Trust, Middlesborough, UK
| | - Clive Peedell
- Department of Radiation Oncology, South Tees Hospitals NHS Foundation Trust, Middlesborough, UK
| | - Judit Boda-Heggemann
- Department of Radiation Oncology, University Medical Center Mannheim University of Heidelberg, Mannheim, Germany
| | - Boris Rudic
- Department of Cardiology, University Medical Center Mannheim University of Heidelberg, Mannheim, Germany
| | - Roland Merten
- Department of Radiation Oncology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Edith M Dieleman
- Amsterdam UMC location University of Amsterdam, Department of Radiation Oncology, Meibergdreef 9, Amsterdam, The Netherlands
| | - Cristopher A Rinaldi
- Department of Cardiology, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Shahreen Ahmad
- Department of Radiation Oncology, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - John Whitaker
- Department of Cardiology, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Pranav Bhagirath
- Amsterdam UMC location University of Amsterdam, Department of Cardiology, Meibergdreef 9, Amsterdam, the Netherlands; Department of Cardiology, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom
| | - Matthew Q Hatton
- Department of Clinical Oncology, Weston Park Hospital, Sheffield, UK
| | - Stephen Riley
- Department of Clinical Oncology, Weston Park Hospital, Sheffield, UK
| | - Melanie Grehn
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Luis Schiappacasse
- Department of Radiation Oncology, Lausanne University Hospital, Lausanne, Switzerland
| | - Oliver Blanck
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Stephan Hohmann
- Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Etienne Pruvot
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Pieter G Postema
- Amsterdam UMC location University of Amsterdam, Department of Cardiology, Meibergdreef 9, Amsterdam, the Netherlands.
| |
Collapse
|
3
|
Mori A, Kuribayashi T, Haida H, Funaishi K, Kasahara H, Harada Y, Yoshimoto T. Pacemaker Relocation for Radiation Against Overlapping Lung Cancer. Cureus 2023; 15:e49921. [PMID: 38174167 PMCID: PMC10763980 DOI: 10.7759/cureus.49921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/04/2023] [Indexed: 01/05/2024] Open
Abstract
We experienced a patient after pacemaker (PM) implantation who had lung cancer of the left upper lobe that developed just behind the PM. The patient was an 81-year-old man with many complications. Radiation was the only treatment option. The PM had to be moved to another place to avoid direct radiation exposure to it. An epicardial pacing lead was implanted on the right ventricular epicardium, and the new generator was implanted in the abdomen. The patient was treated with a total of 62 Gy of radiotherapy for lung cancer, achieving a temporary shrinkage of the tumor. During the radiotherapy period, the PM functioned well without harmful events. When radiation therapy is needed in cases where the tumor overlaps the PM, relocation surgery using an epicardial pacing lead may be a useful option.
Collapse
Affiliation(s)
- Atsuo Mori
- Cardiovascular Surgery, Kawasaki Municipal Hospital, Kawasaki, JPN
| | | | - Hirofumi Haida
- Cardiovascular Surgery, Kawasaki Municipal Hospital, Kawasaki, JPN
| | - Koji Funaishi
- Cardiovascular Surgery, Kawasaki Municipal Hospital, Kawasaki, JPN
| | | | - Yuko Harada
- Internal Medicine, Harada Naika Clinic, Kawasaki, JPN
- Cardiology, Kawasaki Municipal Ida Hospital, Kawasaki, JPN
| | | |
Collapse
|
4
|
Yoshida T, Murayama S, Yasui K, Tomida T, Urikura A. Pacemaker Malfunction During Passive Proton Beam Therapy for Localized Prostate Cancer: Case Reports and a Literature Review. Cureus 2023; 15:e46223. [PMID: 37908917 PMCID: PMC10613830 DOI: 10.7759/cureus.46223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/29/2023] [Indexed: 11/02/2023] Open
Abstract
We report two cases of pacemaker malfunction occurring during proton beam therapy (PBT) for localized prostate cancer treatment. The first case involved mode changes in the pacemaker, while the second exhibited prolongation of the RR interval. Remarkably, both cases did not manifest significant clinical changes. Our findings indicate that careful consideration should be given to passive PBT in patients with localized prostate cancer who have pacemakers, like the considerations in patients with thoracic and abdominal cancers. Moreover, our report highlights the importance of recognizing potential cardiac implantable electronic devices malfunction in various PBT scenarios.
Collapse
Affiliation(s)
- Tsukasa Yoshida
- Department of Diagnostic Radiology, Shizuoka Cancer Center, Shizuoka, JPN
| | - Shigeyuki Murayama
- Department of Radiation and Proton Therapy, Shizuoka Cancer Center, Shizuoka, JPN
| | - Kazuaki Yasui
- Department of Radiation and Proton Therapy, Shizuoka Cancer Center, Shizuoka, JPN
| | - Tetsuya Tomida
- Department of Radiation and Proton Therapy, Shizuoka Cancer Center, Shizuoka, JPN
| | - Atsushi Urikura
- Department of Radiological Technology, Radiological Diagnosis, National Cancer Center Hospital, Tokyo, JPN
| |
Collapse
|
5
|
Defaye P, Biffi M, El-Chami M, Boveda S, Glikson M, Piccini J, Vitolo M. Cardiac pacing and lead devices management: 25 years of research at EP Europace journal. Europace 2023; 25:euad202. [PMID: 37421338 PMCID: PMC10450798 DOI: 10.1093/europace/euad202] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 07/03/2023] [Indexed: 07/10/2023] Open
Abstract
AIMS Cardiac pacing represents a key element in the field of electrophysiology and the treatment of conduction diseases. Since the first issue published in 1999, EP Europace has significantly contributed to the development and dissemination of the research in this area. METHODS In the last 25 years, there has been a continuous improvement of technologies and a great expansion of clinical indications making the field of cardiac pacing a fertile ground for research still today. Pacemaker technology has rapidly evolved, from the first external devices with limited longevity, passing through conventional transvenous pacemakers to leadless devices. Constant innovations in pacemaker size, longevity, pacing mode, algorithms, and remote monitoring highlight that the fascinating and exciting journey of cardiac pacing is not over yet. CONCLUSION The aim of the present review is to provide the current 'state of the art' on cardiac pacing highlighting the most important contributions from the Journal in the field.
Collapse
Affiliation(s)
- Pascal Defaye
- Cardiology Department, University Hospital and Grenoble Alpes University, CS 10217, Grenoble Cedex 9, Grenoble 38043, France
| | - Mauro Biffi
- Cardiology Unit, Cardiac Thoracic and Vascular Department, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Mikhael El-Chami
- Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Serge Boveda
- Clinique Pasteur, Heart Rhythm Department, Toulouse, France
| | - Michael Glikson
- Cardiology Department, Jesselson Integrated Heart Center Shaare Zedek Medical Center and Hebrew University Faculty of Medicine, Jerusalem, Israel
| | - Jonathan Piccini
- Duke University, Duke Clinical Research Institute, Durham, NC, USA
| | - Marco Vitolo
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Modena, Italy
- Clinical and Experimental Medicine PhD Program, University of Modena and Reggio Emilia, Modena, Italy
| |
Collapse
|
6
|
Mirzaei M, Rowshanfarzad P, Gill S, Ebert MA, Dass J. Risk of cardiac implantable device malfunction in cancer patients receiving proton therapy: an overview. Front Oncol 2023; 13:1181450. [PMID: 37469405 PMCID: PMC10352826 DOI: 10.3389/fonc.2023.1181450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 06/12/2023] [Indexed: 07/21/2023] Open
Abstract
Age is a risk factor for both cardiovascular disease and cancer, and as such radiation oncologists frequently see a number of patients with cardiac implantable electronic devices (CIEDs) receiving proton therapy (PT). CIED malfunctions induced by PT are nonnegligible and can occur in both passive scattering and pencil beam scanning modes. In the absence of an evidence-based protocol, the authors emphasise that this patient cohort should be managed differently to electron- and photon- external beam radiation therapy (EBRT) patients due to distinct properties of proton beams. Given the lack of a PT-specific guideline for managing this cohort and limited studies on this important topic; the process was initiated by evaluating all PT-related CIED malfunctions to provide a baseline for future reporting and research. In this review, different modes of PT and their interactions with a variety of CIEDs and pacing leads are discussed. Effects of PT on CIEDs were classified into a variety of hardware and software malfunctions. Apart from secondary neutrons, cumulative radiation dose, dose rate, CIED model/manufacturer, distance from CIED to proton field, and materials used in CIEDs/pacing leads were all evaluated to determine the probability of malfunctions. The importance of proton beam arrangements is highlighted in this study. Manufacturers should specify recommended dose limits for patients undergoing PT. The establishment of an international multidisciplinary team dedicated to CIED-bearing patients receiving PT may be beneficial.
Collapse
Affiliation(s)
- Milad Mirzaei
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
- Department of Medical Imaging and Radiation Sciences, School of Biomedical Sciences, Monash University, Clayton, VIC, Australia
| | - Pejman Rowshanfarzad
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
| | - Suki Gill
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
| | - Martin A. Ebert
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
- School of Physics, Mathematics and Computing, The University of Western Australia, Crawley, WA, Australia
| | - Joshua Dass
- Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia
| |
Collapse
|
7
|
Gevaert SA, Halvorsen S, Sinnaeve PR, Sambola A, Gulati G, Lancellotti P, Van Der Meer P, Lyon AR, Farmakis D, Lee G, Boriani G, Wechalekar A, Okines A, Asteggiano R, Combes A, Pfister R, Bergler-Klein J, Lettino M. Evaluation and management of cancer patients presenting with acute cardiovascular disease: a Clinical Consensus Statement of the Acute CardioVascular Care Association (ACVC) and the ESC council of Cardio-Oncology—part 2: acute heart failure, acute myocardial diseases, acute venous thromboembolic diseases, and acute arrhythmias. EUROPEAN HEART JOURNAL. ACUTE CARDIOVASCULAR CARE 2022; 11:865-874. [DOI: 10.1093/ehjacc/zuac107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 08/29/2022] [Indexed: 12/05/2022]
Abstract
Abstract
Advances in treatment, common cardiovascular (CV) risk factors and the ageing of the population have led to an increasing number of cancer patients presenting with acute CV diseases. These events may be related to cancer itself or cancer treatment. Acute cardiac care specialists must be aware of these acute CV complications and be able to manage them. This may require an individualized and multidisciplinary approach. The management of acute coronary syndromes and acute pericardial diseases in cancer patients was covered in part 1 of a clinical consensus document. This second part focusses on acute heart failure, acute myocardial diseases, venous thromboembolic diseases and acute arrhythmias.
Collapse
Affiliation(s)
- Sofie A Gevaert
- Department of Cardiology, Ghent University Hospital , Gent , Belgium
| | - Sigrun Halvorsen
- Department of Cardiology, Oslo University Hospital Ulleval, and University of Oslo , Oslo , Norway
| | - Peter R Sinnaeve
- Department of Cardiology, University Hospital Leuven , Leuven , Belgium
| | - Antonia Sambola
- Department of Cardiology, University Hospital Vall d’Hebron, Universitat Autonòma, CIBER-CV , Barcelona , Spain
| | - Geeta Gulati
- Department of Cardiology, Oslo University Hospital Ulleval, and University of Oslo , Oslo , Norway
| | - Patrizio Lancellotti
- University of Liège Hospital, GIGA Cardiovascular Science, Department of Cardiology , CHU Sart Tilman, Liège , Belgium
| | - Peter Van Der Meer
- Department of Cardiology, University of Groningen, University Medical Center Groningen , Groningen , The Netherlands
| | - Alexander R Lyon
- Cardio-Oncology Clinic at Royal Brompton Hospital and Imperial College London , London , UK
| | | | - Geraldine Lee
- Florence Nightingale Faculty of Nursing, Midwifery and Palliative Care, King’s College , London , UK
| | - Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia , Policlinico Di Modena, Modena , Italy
| | - Ashutosh Wechalekar
- Department of Haematology, University College London/University College London Hospitals , London , UK
| | - Alicia Okines
- Department of Medicine, The Royal Marsden NHS Foundation Trust , London , UK
| | - Riccardo Asteggiano
- Insubria University , Varese , Italy
- LARC (Laboratorio Analisi e Ricerca Clinica) , Turin , Italy
| | - Alain Combes
- Medical-Surgical ICU, Hôpital Pitié–Salpêtrière , Paris , France
- Sorbonne University, Institute of Cardiometabolism and Nutrition , Paris , France
| | - Roman Pfister
- Department III of Internal Medicine, Heart Center, University of Cologne , Cologne , Germany
| | - Jutta Bergler-Klein
- Department of Cardiology, University Clinic of Internal Medicine II, Medical University of Vienna , Vienna , Austria
| | - Maddalena Lettino
- Department of Cardiology, San Gerardo Hospital, ASST-Monza , Monza , Italy
| |
Collapse
|
8
|
Lyon AR, López-Fernández T, Couch LS, Asteggiano R, Aznar MC, Bergler-Klein J, Boriani G, Cardinale D, Cordoba R, Cosyns B, Cutter DJ, de Azambuja E, de Boer RA, Dent SF, Farmakis D, Gevaert SA, Gorog DA, Herrmann J, Lenihan D, Moslehi J, Moura B, Salinger SS, Stephens R, Suter TM, Szmit S, Tamargo J, Thavendiranathan P, Tocchetti CG, van der Meer P, van der Pal HJH. 2022 ESC Guidelines on cardio-oncology developed in collaboration with the European Hematology Association (EHA), the European Society for Therapeutic Radiology and Oncology (ESTRO) and the International Cardio-Oncology Society (IC-OS). Eur Heart J 2022; 43:4229-4361. [PMID: 36017568 DOI: 10.1093/eurheartj/ehac244] [Citation(s) in RCA: 684] [Impact Index Per Article: 342.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
|
9
|
Stühlinger M, Burri H, Vernooy K, Garcia R, Lenarczyk R, Sultan A, Brunner M, Sabbag A, Özcan EE, Ramos JT, Di Stolfo G, Suleiman M, Tinhofer F, Aristizabal JM, Cakulev I, Eidelman G, Yeo WT, Lau DH, Mulpuru SK, Nielsen JC, Heinzel F, Prabhu M, Rinaldi CA, Sacher F, Guillen R, de Pooter J, Gandjbakhch E, Sheldon S, Prenner G, Mason PK, Fichtner S, Nitta T. EHRA consensus on prevention and management of interference due to medical procedures in patients with cardiac implantable electronic devices. Europace 2022; 24:1512-1537. [PMID: 36228183 DOI: 10.1093/europace/euac040] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023] Open
Affiliation(s)
- Markus Stühlinger
- Department of Internal Medicine III - Cardiology and Angiology, Medical University of Innsbruck, Innsbruck, Austria
| | - Haran Burri
- Department of Cardiology, University Hospital of Geneva, Geneva, Switzerland
| | - Kevin Vernooy
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Rodrigue Garcia
- Department of Cardiology, University Hospital of Poitiers, Poitiers, France
- Department of Cardiology, Rigshospitalet, Copenhagen, Denmark
| | - Radoslaw Lenarczyk
- Department of Cardiology, Congenital Heart Disease and Electrotherapy, Medical University of Silesia, Silesian Center of Heart Diseases, Zabrze, Poland
- Medical University of Silesia, Division of Medical Sciences, Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Silesian Center for Heart Diseases, Zabrze, Poland
| | - Arian Sultan
- Department of Electrophysiology, Heart Center at University Hospital Cologne, Cologne, Germany
| | - Michael Brunner
- Department of Cardiology and Medical Intensive Care, St Josefskrankenhaus, Freiburg, Germany
| | - Avi Sabbag
- The Davidai Center for Rhythm Disturbances and Pacing, Chaim Sheba Medical Center, Ramat Gan, Israel
| | - Emin Evren Özcan
- Heart Rhythm Management Center, Dokuz Eylul University, İzmir, Turkey
| | - Jorge Toquero Ramos
- Cardiac Arrhythmia and Electrophysiology Unit, Cardiology Department, Puerta de Hierro University Hospital, Majadahonda, Madrid, Spain
| | - Giuseppe Di Stolfo
- Cardiac Intensive Care and Arrhythmology Unit, Fondazione IRCCS Casa Sollievo della Sofferenza, San Giovanni Rotondo, Italy
| | - Mahmoud Suleiman
- Cardiology/Electrophysiology, Rambam Health Care Campus, Haifa, Israel
| | | | | | - Ivan Cakulev
- University Hospitals of Cleveland, Case Western University, Cleveland, OH, USA
| | - Gabriel Eidelman
- San Isidro's Central Hospital, Diagnóstico Maipú, Buenos Aires Province, Argentina
| | - Wee Tiong Yeo
- Department of Cardiology, National University Heart Centre, Singapore, Singapore
| | - Dennis H Lau
- Centre for Heart Rhythm Disorders, The University of Adelaide and Royal Adelaide Hospital, Adelaide, SA, Australia
| | | | - Jens Cosedis Nielsen
- Department of Cardiology, Aarhus University Hospital, and Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Frank Heinzel
- Department of Cardiology, Charité University Medicine, Campus Virchow-Klinikum, 13353 Berlin, Germany
| | - Mukundaprabhu Prabhu
- Associate Professor in Cardiology, In charge of EP Division, Kasturba Medical College Manipal, Manipal, Karnataka, India
| | | | - Frederic Sacher
- Bordeaux University Hospital, Univ. Bordeaux, Bordeaux, France
| | - Raul Guillen
- Sanatorio Adventista del Plata, Del Plata Adventist University Entre Rios Argentina, Entre Rios, Argentina
| | - Jan de Pooter
- Professor of Cardiology, Ghent University, Deputy Head of Clinic, Heart Center UZ Gent, Ghent, Belgium
| | - Estelle Gandjbakhch
- AP-HP Sorbonne Université, Hôpital Pitié-Salpêtrière, Institut de Cardiologie, ICAN, Paris, France
| | - Seth Sheldon
- The Department of Cardiovascular Medicine, University of Kansas Health System, Kansas City, KS 66160, USA
| | | | - Pamela K Mason
- Director, Electrophysiology Laboratory, University of Virginia, Charlottesville, VA, USA
| | - Stephanie Fichtner
- LMU Klinikum, Medizinische Klinik und Poliklinik I, Campus Großhadern, München, Germany
| | - Takashi Nitta
- Emeritus Professor, Nippon Medical School, Presiding Consultant of Cardiology, Hanyu General Hospital, Saitama, Japan
| |
Collapse
|
10
|
Linares Gavidia S, Rahman A. Radiotherapy for a Patient With Spinal Cord Stimulation: A Case Report. A A Pract 2022; 16:e01624. [PMID: 37944536 DOI: 10.1213/xaa.0000000000001624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2023]
Abstract
Cancer-related neuropathic pain is prevalent in up to 40% of patients with advanced disease. Spinal cord stimulation (SCS) is used to treat chronic pain when other treatments are ineffective. Radiotherapy is an established treatment modality for patients with oncological diseases. The ionizing radiation from radiotherapy can potentially damage electrical devices, including SCS devices. Additionally, all parts of SCS can potentially interfere with radiotherapy delivery. We present a case of successful administration of radiotherapy to a patient without damaging the SCS device implanted in proximity to the target lesion.
Collapse
Affiliation(s)
- Samuel Linares Gavidia
- From the Department of Anesthesiology and Pain Management, John H. Stroger Hospital of Cook County, Chicago, Illinois
| | | |
Collapse
|
11
|
Lyon AR, López-Fernández T, Couch LS, Asteggiano R, Aznar MC, Bergler-Klein J, Boriani G, Cardinale D, Cordoba R, Cosyns B, Cutter DJ, de Azambuja E, de Boer RA, Dent SF, Farmakis D, Gevaert SA, Gorog DA, Herrmann J, Lenihan D, Moslehi J, Moura B, Salinger SS, Stephens R, Suter TM, Szmit S, Tamargo J, Thavendiranathan P, Tocchetti CG, van der Meer P, van der Pal HJH. 2022 ESC Guidelines on cardio-oncology developed in collaboration with the European Hematology Association (EHA), the European Society for Therapeutic Radiology and Oncology (ESTRO) and the International Cardio-Oncology Society (IC-OS). Eur Heart J Cardiovasc Imaging 2022; 23:e333-e465. [PMID: 36017575 DOI: 10.1093/ehjci/jeac106] [Citation(s) in RCA: 88] [Impact Index Per Article: 44.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
12
|
The impact of particle radiotherapy on the functioning of cardiac implantable electronic devices: a systematic review of in vitro and in vivo studies according to PICO criteria. Radiol Med 2022; 127:1046-1058. [PMID: 35871428 PMCID: PMC9508006 DOI: 10.1007/s11547-022-01520-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 06/20/2022] [Indexed: 12/24/2022]
Abstract
The number of oncological patients who may benefit from proton beam radiotherapy (PBT) or carbon ion radiotherapy (CIRT), overall referred to as particle radiotherapy (RT), is expected to strongly increase in the next future, as well as the number of cardiological patients requiring cardiac implantable electronic devices (CIEDs). The management of patients with a CIED requiring particle RT deserves peculiar attention compared to those undergoing conventional photon beam RT, mostly due to the potential generation of secondary neutrons by particle beams interactions. Current consensus documents recommend managing these patients as being at intermediate/high risk of RT-induced device malfunctioning regardless of the dose on the CIED and the beam delivery method used, despite the last one significantly affects secondary neutrons generation (very limited neutrons production with active scanning as opposed to the passive scattering technique). The key issues for the current review were expressed in four questions according to the Population, Intervention, Control, Outcome criteria. Three in vitro and five in vivo studies were included. Based on the available data, PBT and CIRT with active scanning have a limited potential to interfere with CIED that has only emerged from in vitro study so far, while a significant potential for neutron-related, not severe, CIED malfunctions (resets) was consistently reported in both clinical and in vitro studies with passive scattering.
Collapse
|
13
|
Bhimani F, Johnson K, Brodin NP, Tomé WA, Fox J, Mehta K, McEvoy M, Feldman S. Case Report: Can Targeted Intraoperative Radiotherapy in Patients With Breast Cancer and Pacemakers be the New Standard of Care? Front Oncol 2022; 12:927174. [PMID: 35903710 PMCID: PMC9315093 DOI: 10.3389/fonc.2022.927174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 06/20/2022] [Indexed: 11/17/2022] Open
Abstract
Background Partial breast irradiation with Intra-operative radiotherapy (IORT) has become a popular management option as opposed to whole breast radiation using external beam radiotherapy for breast cancer patients. While previous studies have highlighted the use of IORT in breast cancer patients, there is a scarcity of literature on the use of IORT in those who also have ipsilateral pacemakers. Thus, the aim of our case report is to highlight the applicability of IORT in breast cancer patients who also have a pacemaker. Case Reports Two female patients with an implanted dual-chamber pacemaker presented with a diagnosis of left-sided invasive ductal carcinoma on mammogram. Mammography of the left breast revealed a 10 mm and 7 mm spiculated mass, respectively, further confirmed with an ultrasound-guided core biopsy that was conclusive of clinical Stage I T1 N0 grade 2, ER +, PR + Her2 – invasive ductal carcinoma. They met our eligibility criteria for IORT, which is being performed as a registry trial. These patients underwent a wide excision lumpectomy along with IORT. Conclusion Our findings underscore the successful use of targeted IORT for breast-conserving surgery in a patient with invasive ductal carcinoma and pacemaker, hence eliminating the necessity for relocating pacemaker surgeries in these patients. Furthermore, no device failure or malfunction for the pacemaker was recorded before, during, or after the surgery, demonstrating the safety of using IORT in patients with preinstalled pacemaker despite a lack of evidence on safe radiation dosage or manufacturer guidelines. Nonetheless, the effects of IORT on pacemaker < 10 cm were not studied in our patients and further clinical studies are recommended to reinforce the applicability and safe distance of IORT in breast cancer patients with pacemaker.
Collapse
Affiliation(s)
- Fardeen Bhimani
- Breast Surgery Division, Department of Surgery, Montefiore Medical Center, Montefiore Einstein Center for Cancer Care, Bronx, NY, United States
| | - Kelly Johnson
- Breast Surgery Division, Department of Surgery, Montefiore Medical Center, Montefiore Einstein Center for Cancer Care, Bronx, NY, United States
| | - N. Patrik Brodin
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY, United States
| | - Wolfgang A. Tomé
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY, United States
| | - Jana Fox
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY, United States
| | - Keyur Mehta
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY, United States
| | - Maureen McEvoy
- Breast Surgery Division, Department of Surgery, Montefiore Medical Center, Montefiore Einstein Center for Cancer Care, Bronx, NY, United States
| | - Sheldon Feldman
- Breast Surgery Division, Department of Surgery, Montefiore Medical Center, Montefiore Einstein Center for Cancer Care, Bronx, NY, United States
- *Correspondence: Sheldon Feldman,
| |
Collapse
|
14
|
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Translation of the document prepared by the Czech Society of Cardiology. COR ET VASA 2022. [DOI: 10.33678/cor.2022.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
15
|
Frey P, Irles D, Dompnier A, Akret C, Hosu IC, Narayanan K, Mazoyer F, Yayehd K, Guillon B, Marijon E. Cardiac Implantable Electronic Device Dysfunctions in Patients Undergoing Radiotherapy A Prospective Cohort Study. J Cardiovasc Electrophysiol 2022; 33:1013-1023. [PMID: 35299286 DOI: 10.1111/jce.15449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 02/28/2022] [Accepted: 03/07/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND Increasing numbers of patients with cardiac implantable electronic devices (CIEDs) are undergoing radiotherapy for cancer. The aim of the study was to prospectively evaluate the incidence, characteristics, and associated factors of CIED dysfunctions related to radiotherapy. METHODS Between April 2013 and March 2020, all patients with a CIED who underwent ≥1 radiotherapy session were enrolled. Patients were monitored according to a systematic protocol, including device interrogation before the 1st and after each radiotherapy session. The primary endpoint was CIED dysfunction, defined as oversensing, total or partial deprogramming, and/or unrecoverable reset. RESULTS We included a total of 92 CIED radiotherapy courses: 77 (83.7%) in patients with a pacemaker and 15 (16.3%) in those with an implantable cardioverter defibrillator. Overall, 13 dysfunctions (14.1%) were observed during 92 courses (1509 sessions), giving an incidence of 0.9 per 100 sessions. These included nine deprogramming (three total resets to back-up pacing mode and six partial deprogramming that were all successfully reprogrammed), three transient oversensing, and one unrecoverable oversensing requiring CIED and leads replacement. There were no adverse clinical events related to device dysfunction. In multivariable analysis, neutron-producing irradiation (odds ratio [OR], 5.59; 95% confidence interval [CI], 1.09-28.65; P=0.039) and cumulative tumor dose (OR, 1.05; 95% CI, 1.01-1.10; P=0.007) remained significantly associated with CIED dysfunction. CONCLUSIONS In this prospective study, transient or permanent subclinical CIED dysfunction occurred in 14.1% of radiotherapy courses. Our findings emphasize the importance of high-energy beams and neutron-producing irradiation in risk assessment. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Pierre Frey
- Department of cardiology, Centre Hospitalier Annecy Genevois, 1 Avenue de l'Hôpital, 74370, Metz-Tessy, France
| | - Didier Irles
- Department of cardiology, Centre Hospitalier Annecy Genevois, 1 Avenue de l'Hôpital, 74370, Metz-Tessy, France
| | - Antoine Dompnier
- Department of cardiology, Centre Hospitalier Annecy Genevois, 1 Avenue de l'Hôpital, 74370, Metz-Tessy, France
| | - Chrystelle Akret
- Department of cardiology, Centre Hospitalier Annecy Genevois, 1 Avenue de l'Hôpital, 74370, Metz-Tessy, France
| | - Iolanda C Hosu
- Department of radiotherapy, Centre Hospitalier Annecy Genevois, 1 Avenue de l'Hôpital, 74370, Metz-Tessy, France
| | - Kumar Narayanan
- University of Paris, Paris-Cardiovascular Research Center, INSERM, F-75015, Paris, France.,Medicover Hospitals, Hyderabad, India
| | - Fréderic Mazoyer
- Department of radiotherapy, Centre Hospitalier Annecy Genevois, 1 Avenue de l'Hôpital, 74370, Metz-Tessy, France
| | - Komlavi Yayehd
- Department of cardiology, CHU Campus Lomé, 03 BP, 30284, Lomé, Togo
| | - Benoît Guillon
- Department of cardiology, University Hospital Besancon, 25000, Besancon, France.,EA3920, University of Burgundy-Franche-Comté, Besancon, France
| | - Eloi Marijon
- University of Paris, Paris-Cardiovascular Research Center, INSERM, F-75015, Paris, France.,Cardiology department, European Georges Pompidou Hospital, 75908, Paris, Cedex, 15, France
| |
Collapse
|
16
|
Daniela Falco M, Andreoli S, Delana A, Barbareschi A, De Filippo P, Leidi C, Marini M, Appignani M, Genovesi D, Di Girolamo E. In-vitro investigation of cardiac implantable electronic device malfunction during and after direct photon exposure: A three-centres experience. Phys Med 2022; 94:94-101. [PMID: 35007940 DOI: 10.1016/j.ejmp.2021.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 11/26/2021] [Accepted: 12/28/2021] [Indexed: 10/19/2022] Open
Abstract
PURPOSE Radiotherapy may cause malfunction of implantable cardioverter-defibrillators (ICDs) and pacemakers (PMs). We carried-out a multicentre randomized in-vitro study on 65 ICDs and 145 PMs to evaluate malfunctions during and after direct irradiation to doses up to 10 Gy. METHODS Three centres equipped with different linear accelerator and treatment-planning systems participated in the study. Computed Tomography (CT) acquisitions were performed to build the treatment plans. All devices were exposed to dose of 2, 5, or 10 Gy (6 MV). All devices underwent a baseline examination and 64 wireless real-time telemetry-transmissions (47 ICDs and 17 PMs) were monitored during photon exposures. All devices were interrogated after exposure and once monthly for six subsequent months. RESULTS Fifty-four of the 64 wireless-enabled CIEDs (84.4%) recorded noise-related interferences during exposure. In detail, 40/47 ICDs (85.1%) reported interference, of which 16 ICDs (34%) reported potentially clinically relevant pacing inhibition and inappropriate detections. Following exposure, a soft reset occurred in 1/145 PM (0.7%) while 7/145 PMs (4.8%) reported battery issues. During the six-month follow-up, 1/145 PM (0.7%) reported a soft reset, while 12/145 more PMs (8.3%) and 1/64 ICD (1.5%) showed abnormal battery depletion. All reported issues occurred independently of exposure dose. Finally, irreversible effects on software and battery life occurred in only non-MRI-compatible devices. CONCLUSION ICDs mostly featured real-time transient sensing issues, while PMs mostly experienced long-term battery or software issues that were observed immediately following radiation exposure and during follow-up. Irreversible effects on battery life and software occurred in only non-MRI-compatible devices.
Collapse
Affiliation(s)
- Maria Daniela Falco
- Department of Radiation Oncology, "G. D'Annunzio" University, "SS. Annunziata" Hospital, Chieti, Italy.
| | - Stefano Andreoli
- Medical Physics Unit, ASST "Papa Giovanni XXIII", Bergamo, Italy
| | - Anna Delana
- Medical Physics Unit, "S. Chiara" Hospital, Trento, Italy
| | | | - Paolo De Filippo
- Electrophysiology Unit, ASST "Papa Giovanni XXIII", Bergamo, Italy
| | - Cristina Leidi
- Electrophysiology Unit, ASST "Papa Giovanni XXIII", Bergamo, Italy
| | | | | | - Domenico Genovesi
- Department of Radiation Oncology, "G. D'Annunzio" University, "SS. Annunziata" Hospital, Chieti, Italy
| | | |
Collapse
|
17
|
Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, Barrabés JA, Boriani G, Braunschweig F, Brignole M, Burri H, Coats AJ, Deharo JC, Delgado V, Diller GP, Israel CW, Keren A, Knops RE, Kotecha D, Leclercq C, Merkely B, Starck C, Thylén I, Tolosana JM. Grupo de trabajo sobre estimulación cardiaca y terapia de resincronización cardiaca de la Sociedad Europea de Cardiología (ESC). Rev Esp Cardiol 2022. [DOI: 10.1016/j.recesp.2021.10.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
18
|
Okano N, Sakai M, Shibuya K, Tsuda K, Kanzaki T, Sano M, Kaneko Y, Ohno T. Safety verification of carbon-ion radiotherapy for patients with cardiac implantable electronic devices (CIEDs). JOURNAL OF RADIATION RESEARCH 2022; 63:122-127. [PMID: 34747483 PMCID: PMC8776694 DOI: 10.1093/jrr/rrab105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 09/17/2021] [Indexed: 06/13/2023]
Abstract
According to guidelines, carbon-ion beam therapy is considered to carry a high safety risk for patients with cardiac implantable electronic devices (CIEDs), although the actual impacts remain unclear. In this study, we investigated the safety of carbon-ion beam therapy in patients with CIEDs. Patients with CIEDs who underwent carbon-ion therapy at Gunma University Heavy Ion Medical Center between June 2010 and December 2019 were identified and investigated for abnormalities in the operation of their CIEDs, such as oversensing and resetting during irradiation, and abnormalities in operation after treatment. In addition, the risk of irradiation from carbon-ion beam therapy was evaluated by model simulations. Twenty patients (22 sites) with CIEDs were identified, 19 with pacemakers and one with an implantable cardioverter-defibrillator (ICD). Treatments were completed without any problems, except for one case in which the treatment was discontinued because of worsening of the primary disease. Monte Carlo simulation indicated that the carbon beam irradiation produced neutrons at a constant and high level in the irradiation field. Nevertheless, with the distances between the CIEDs and the irradiation fields in the analyzed cases, the quantity of neutrons at the CIEDs was lower than that within the irradiation. Although carbon-ion beam therapy can be safely administered to patients with CIEDs, it is advisable to perform the therapy with sufficient preparation and backup devices because of the risks involved.
Collapse
Affiliation(s)
- Naoko Okano
- Corresponding author. Naoko Okano, Gunma University, Heavy Ion Medical Center, 371-8511, 3-39-22 Showa-machi Maebashi, Gunma, Japan. Tel: (+81) 27-220-8383; Fax: (+81) 27-220-8384;
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, Barrabés JA, Boriani G, Braunschweig F, Brignole M, Burri H, Coats AJS, Deharo JC, Delgado V, Diller GP, Israel CW, Keren A, Knops RE, Kotecha D, Leclercq C, Merkely B, Starck C, Thylén I, Tolosana JM, Leyva F, Linde C, Abdelhamid M, Aboyans V, Arbelo E, Asteggiano R, Barón-Esquivias G, Bauersachs J, Biffi M, Birgersdotter-Green U, Bongiorni MG, Borger MA, Čelutkienė J, Cikes M, Daubert JC, Drossart I, Ellenbogen K, Elliott PM, Fabritz L, Falk V, Fauchier L, Fernández-Avilés F, Foldager D, Gadler F, De Vinuesa PGG, Gorenek B, Guerra JM, Hermann Haugaa K, Hendriks J, Kahan T, Katus HA, Konradi A, Koskinas KC, Law H, Lewis BS, Linker NJ, Løchen ML, Lumens J, Mascherbauer J, Mullens W, Nagy KV, Prescott E, Raatikainen P, Rakisheva A, Reichlin T, Ricci RP, Shlyakhto E, Sitges M, Sousa-Uva M, Sutton R, Suwalski P, Svendsen JH, Touyz RM, Van Gelder IC, Vernooy K, Waltenberger J, Whinnett Z, Witte KK. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Europace 2022; 24:71-164. [PMID: 34455427 DOI: 10.1093/europace/euab232] [Citation(s) in RCA: 124] [Impact Index Per Article: 62.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
20
|
Escande A, Frey P, Lacornerie T, Mervoyer E, Chargari C, Laurans M, Mornex F, Marijon É, Giraud P. Radiotherapy for patient with cardiac implantable electronic device, consensus from French radiation oncology society. Cancer Radiother 2021; 26:404-410. [PMID: 34969621 DOI: 10.1016/j.canrad.2021.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Radiotherapy in patients with cardiac implantable electronic device such as pacemakers or defibrillators, is a clinical situation that is becoming increasingly common. There is a risk of interaction between the magnetic field induced by accelerators and the cardiac implantable electronic device, but also a risk of device dysfunction due to direct and/or indirect irradiation if the cardiac implantable electronic device is in the field of treatment. The risk can be dose-dependent, but it is most often independent of the total dose and occurs randomly in case of neutron production (stochastic effect). The presence of this type of device is therefore described as a contraindication for radiotherapy by the French national agency for the safety of medicines and health products (Agence nationale de sécurité du médicament et des produits de santé, ANSM). Nevertheless, since radiotherapy is often possible, it is advisable to respect the recommendations of good practice, in particular the eligibility criteria, the monitoring modalities before, during and after irradiation according to the type of treatment, the dose and the characteristics of the cardiac implantable electronic device. It is sometimes necessary to discuss repositioning the device and/or modifying the treatment plan to minimize the risk of cardiac implantable electronic device dysfunction. We present the update of the recommendations of the French society of oncological radiotherapy on in patients with cardiac implantable electronic device.
Collapse
Affiliation(s)
- A Escande
- Département universitaire de radiothérapie, centre Oscar-Lambret, 3, rue Frédéric-Combemale, 59000 Lille, France; Faculté de médecine Henri-Warembourg, université de Lille, 59000 Lille, France; UMR 9189, Centre de recherche en informatique, signal et automatique de Lille (Cristal), 59655 Villeneuve d'Ascq, France.
| | - P Frey
- Département de cardiologie, centre hospitalier Annecy Genevois, 74370 Épagny-Metz-Tessy, France
| | - T Lacornerie
- Département de physique médicale, centre Oscar-Lambret, 3, rue Frédéric-Combemale, 59000 Lille, France
| | - E Mervoyer
- Département de cardiologie, Institut de cancérologie de l'Ouest, 44800 Saint-Herblain, France
| | - C Chargari
- Unité de curiethérapie, département de radiothérapie, Gustave-Roussy, 94805 Villejuif, France
| | - M Laurans
- Service d'oncologie radiothérapie, hôpital européen Georges-Pompidou, Université de Paris, 20, rue Leblanc, 75015 Paris, France
| | - F Mornex
- Département de radiothérapie, centre hospitalier Lyon Sud, 69310 Pierre-Bénite, France
| | - É Marijon
- Département de cardiologie, hôpital européen Georges-Pompidou, 20, rue Leblanc, 75015 Paris, France
| | - P Giraud
- Service d'oncologie radiothérapie, hôpital européen Georges-Pompidou, Université de Paris, 20, rue Leblanc, 75015 Paris, France
| |
Collapse
|
21
|
Ergen SA, Oksüz DC, Karacam S, Dıncbas FO. Management of IMRT in a gastric cancer patient with pacemaker: A case report and review of the literature. J Cancer Res Ther 2021; 17:1559-1561. [PMID: 34916396 DOI: 10.4103/jcrt.jcrt_430_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Due to the prolongation of a lifetime, more cancer patients with cardiac implantable electronic devices are treated by radiotherapy. However, radiation may cause permanent or temporary malfunctions on these devices, and new-generation devices are more sensitive to radiation. Besides, radiotherapy techniques and image guidance methods that may cause different interactions with the functions of the devices have been changed significantly recently. Here, we reported our clinical experience in a patient with a pacemaker who underwent radiotherapy with intensity-modulated radiation therapy (IMRT) due to gastric cancer and reviewed the literature.
Collapse
Affiliation(s)
- Sefika Arzu Ergen
- Department of Radiation Oncology, Cerrahpasa Medical School, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Didem Colpan Oksüz
- Department of Radiation Oncology, Cerrahpasa Medical School, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Songül Karacam
- Department of Radiation Oncology, Cerrahpasa Medical School, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Fazilet Oner Dıncbas
- Department of Radiation Oncology, Cerrahpasa Medical School, Istanbul University-Cerrahpasa, Istanbul, Turkey
| |
Collapse
|
22
|
Zagzoog A, Wronski M, Birnie DH, Yeung C, Baranchuk A, Healey JS, Golian M, Boles U, Carrizo AG, Turner S, Hassan A, Ali E, Kumar SK, Russell S, Shurrab M, Crystal E. Assessment of Radiation-Induced Malfunction in Cardiac Implantable Electronic Devices. CJC Open 2021; 3:1438-1443. [PMID: 34993455 PMCID: PMC8712607 DOI: 10.1016/j.cjco.2021.07.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Accepted: 07/07/2021] [Indexed: 12/25/2022] Open
Abstract
Background Radiation therapy (RT) is a standard cancer treatment modality, and an increasing number of patients with cardiac implantable electronic devices (CIEDs) are being referred for RT. The goals of this study were as follows: (i) to determine the incidence of CIED malfunction following RT; (ii) to characterize the various types of malfunctions that occur; and (iii) to identify risk factors associated with CIED malfunction following RT. Methods A retrospective study of patients with CIEDs who received RT between 2007 and 2018 at 4 Canadian centres (Sunnybrook Health Sciences Centre, Kingston General Hospital, Hamilton Health Sciences Centre, and University of Ottawa Heart Institute) was conducted. Patients underwent CIED interrogation after completion of RT, to assess for late damage to the CIEDs. Data on demographics, devices, and RT were compared for the primary outcome of device malfunction. Results Of 1041 patients with CIEDs who received RT, 811 patients with complete data were included. Device malfunctions occurred in 32 of 811 patients (4%). The most common device malfunctions were reduced ventricular/atrial sensing (in 13 of 32 [41%]), an increase in lead threshold (in 9 of 32 [22%]), lead noise (in 5 of 32 [16%]), and electrical reset (in 2 of 32 [6%]). Higher beam energy (≥ 10 MV) was associated with malfunction (P < 0.0001). Radiation dose was not significantly different between the malfunction and non-malfunction groups (58.3 cGy vs 65 cGy, respectively, P = 0.71). Conclusions Although RT-induced CIED malfunctions are rare (occurring in 4% of patients with a CIED who undergo RT), collaborative efforts between radiation oncologists and cardiac rhythm device clinics to optimize CIED monitoring are needed, to detect and manage CIED malfunctions. Malfunctions are more common in patients receiving higher–beam energy (≥10MV)RT.
Collapse
Affiliation(s)
- Amin Zagzoog
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
- University of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, Canada
| | - Matt Wronski
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - David H. Birnie
- University of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, Canada
| | - Cynthia Yeung
- Kingston General Hospital, Queens School of Medicine, Kingston, Ontario, Canada
| | - Adrian Baranchuk
- Kingston General Hospital, Queens School of Medicine, Kingston, Ontario, Canada
| | - Jeffrey S. Healey
- Hamilton Health Sciences and Centre, McMaster University, Hamilton, Ontario, Canada
| | - Mehrdad Golian
- University of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, Canada
| | - Usama Boles
- Kingston General Hospital, Queens School of Medicine, Kingston, Ontario, Canada
| | - Aldo G. Carrizo
- Hamilton Health Sciences and Centre, McMaster University, Hamilton, Ontario, Canada
| | - Suzette Turner
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Ahmed Hassan
- University of Ottawa Heart Institute, University of Ottawa, Ottawa, Ontario, Canada
| | - Elsayed Ali
- The Ottawa Hospital Cancer Centre, University of Ottawa, Ottawa, Ontario, Canada
| | - Sharath K. Kumar
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Steve Russell
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Mohammed Shurrab
- Health Sciences North, Health Sciences North Research Institute, Northern Ontario School of Medicine, Sudbury, Ontario, Canada
| | - Eugene Crystal
- Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
- Corresponding author: Dr Eugene Crystal, Division of Cardiology, Department of Medicine, D377, 2075 Bayview Ave, Toronto, Onntario M4N 3M5, Canada. Tel.: +1-416-480-6100.
| |
Collapse
|
23
|
Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, Barrabés JA, Boriani G, Braunschweig F, Brignole M, Burri H, Coats AJS, Deharo JC, Delgado V, Diller GP, Israel CW, Keren A, Knops RE, Kotecha D, Leclercq C, Merkely B, Starck C, Thylén I, Tolosana JM. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J 2021; 42:3427-3520. [PMID: 34455430 DOI: 10.1093/eurheartj/ehab364] [Citation(s) in RCA: 807] [Impact Index Per Article: 269.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
24
|
A Review and Analysis of Managing Commonly Seen Implanted Devices for Patients Undergoing Radiation Therapy. Adv Radiat Oncol 2021; 6:100732. [PMID: 34409216 PMCID: PMC8361059 DOI: 10.1016/j.adro.2021.100732] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 03/28/2021] [Accepted: 04/19/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose This review article aims to consolidate information regarding existing and emerging implanted devices used in patients undergoing radiation therapy and to categorize levels of attention needed for each device, including which devices require monitoring throughout treatment. Methods and Materials Based on the collective information from scholar searches, manufacturers' technical reports, and institutional experiences in the past years, commonly present devices in patients with cancer are compiled. This work summarizes cardiac pacemaker, implanted cardiac defibrillator, hepatic pump, intrathecal pain pump, neurostimulator, shunt, loop recorder, and mediport. Three different classifications of implanted devices can be made based on the potential effect of radiation: life-dependent, nonlife-dependent but with adverse effects if overdosed, and devices without electronic circuits. Implanted devices that contain electronic circuits that would be life-dependent or have adverse effects if overdosed, include cardiac pacemakers, implanted cardiac defibrillators, programmable hepatic pumps, pain pumps, neurostimulators, and loop recorders. Results Dose exposure to these devices need to be calculated or measured in vivo, especially for cardiac implanted devices, and they should be minimized to assure continued healthy functioning. Treatment planning techniques should be chosen to reduce entry, exit and internal scatter dose. Lower energy photon beams should be used to decrease potential neutron contamination. Implanted devices without electronic circuits are less of a concern. If a patient is life-dependent on the implanted device, it is not recommended to treat the patient with proton therapy. Conclusions This study reviewed the management of patients with commonly seen implanted devices and summarized a workflow for identifying and planning when a patient has implanted devices. Classifications of implanted devices could help clinicians make proper decisions in regard to patients with specific implanted devices. Lastly, the management of such devices in the era of the pandemic is also discussed in this review article.
Collapse
|
25
|
Kakino R, Nakamura M, Hu N, Iramina H, Tanaka H, Sakurai Y, Mizowaki T. Photoneutron-induced damage reduction for cardiac implantable electronic devices using neutron-shielding sheets in high-energy X-ray radiotherapy: A phantom study. Phys Med 2021; 89:151-159. [PMID: 34371340 DOI: 10.1016/j.ejmp.2021.07.036] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 07/06/2021] [Accepted: 07/28/2021] [Indexed: 12/24/2022] Open
Abstract
PURPOSE To evaluate damage reduction in cardiac implantable electronic devices (CIEDs) caused by photoneutrons in high-energy X-ray radiotherapy using a neutron-shielding sheet (NSS). METHODS The NSS consists of a bolus with a thickness of 1 or 2 cm (Bls1 or Bls2) as a moderator and several absorbers (20%, 50%, or 80% B4C silicone sheet [B4C20, B4C50, or B4C80] or a 40% LiF silicone sheet [LiF40]). First, a linear accelerator (LINAC) with a water-equivalent phantom was modeled in the simulation and measured experimentally. Several NSSs were placed on the phantom, a Eu:LiCaAlF6 scintillator was placed between the phantom and the NSS, and X-rays were irradiated. The relative counts (Cr = counts when placing the NSS or Bls2) were compared between the experiment and simulation. Second, CIED damage was evaluated in the simulation. The relative damage (Dr = damage when placing or not placing the NSS) was compared among all the NSSs. In addition, the γ-ray and leaking X-ray dose from B4C was measured using a dosimetric film. After determining the optimal NSS combination, Dr value analysis was performed by changing the length of one side and the thickness. RESULTS The Cr values of the simulation and experiment agreed within a 30% percentage difference, except for Bare or LiF40-only. The Dr value was reduced by 43% when Bls2 + B4C80 was applied. The photon dose was less than 5 cGy/1500 MU. The Dr values were smaller for the smaller lengths of one side of B4C80 and decreased as the M-layer thickness increased. CONCLUSIONS The CIED damage induced by photoneutrons generated by a LINAC was effectively reduced by applying the optimal NSS.
Collapse
Affiliation(s)
- Ryo Kakino
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; Japan Society for the Promotion of Science, 5-3-1 Kojimachi, Chiyoda-ku, Tokyo 102-0083, Japan
| | - Mitsuhiro Nakamura
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan.
| | - Naonori Hu
- Kansai BNCT Medical Center, Osaka Medical College, 2-7 Daigaku-Machi, Takatsuki, Osaka 569-8686, Japan; Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2 Asashiro-nishi Kumatori-cho, Osaka 590-0494, Japan
| | - Hiraku Iramina
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| | - Hiroki Tanaka
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2 Asashiro-nishi Kumatori-cho, Osaka 590-0494, Japan
| | - Yoshinori Sakurai
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2 Asashiro-nishi Kumatori-cho, Osaka 590-0494, Japan
| | - Takashi Mizowaki
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan
| |
Collapse
|
26
|
Nakamura K, Aoyama T, Kaneda N, Otsuji M, Minami Y, Sakuragi A, Nakamura M. Implantable cardiac pacemaker failure by cumulative dose effects of flattening filter free beams. JOURNAL OF RADIATION RESEARCH 2021; 62:735-739. [PMID: 34036327 PMCID: PMC8273809 DOI: 10.1093/jrr/rrab041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 03/30/2021] [Indexed: 06/12/2023]
Abstract
Cumulative dose effects, which are one of the main causes of errors that occur when an implantable cardiac pacemaker (ICP) is irradiated with ionizing radiation, induce permanent failure in ICPs. Although flattening filter free (FFF) beams, which are often used in stereotactic radiotherapy, are known to have different characteristics from conventional (with flattening filter [WFF]) beams, the cumulative dose effects on ICPs with FFF beams have been under-investigated. This study investigates ICP failure induced by cumulative dose effects of FFF beams. When the ICP placed in the center of the irradiation field was irradiated with 10 MV-FFF at 24 Gy/min, the cumulative dose at which failure occurred was evaluated on the basis of the failure criteria associated with high cumulative dose as described in the American Association of Physicists in Medicine Task Group 203. The ICP failures such as a mild battery depletion at a cumulative dose of 10 Gy, pacing-output voltage change >25% at a cumulative dose of 122 Gy, and the loss of telemetry capability at cumulative dose 134 Gy were induced by cumulative dose effects. The cumulative doses by which the cumulative dose effects of FFF beams induced ICP failure were not very different from those reported in previous studies with WFF beams. Therefore, radiotherapy with FFF beams (and WFF beams) for patients with ICP requires appropriate management for minimizing the cumulative dose effects.
Collapse
Affiliation(s)
- Kazuhiko Nakamura
- Corresponding author. Kazuhiko Nakamura, Department of Radiology, Aichi Medical University Hospital, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan. E-mail: ; Fax: +81-561-78-6228
| | - Takahiro Aoyama
- Department of Radiation Oncology, Aichi Cancer Center, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi 464-8681 Japan
- Graduate School of Medicine, Aichi Medical University, 1-1 Yazako-karimata, Nagakute, Aichi 480-1195 Japan
| | - Naoki Kaneda
- Department of Radiology, Aichi Medical University Hospital, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Masashi Otsuji
- Department of Clinical Engineering, Aichi Medical University Hospital, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Yoshitaka Minami
- Department of Radiology, Aichi Medical University Hospital, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Ami Sakuragi
- Department of Radiology, Aichi Medical University Hospital, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| | - Masaru Nakamura
- Department of Radiology, Aichi Medical University Hospital, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195 Japan
| |
Collapse
|
27
|
Radiotherapy in patient with an automated implantable cardioverter defibrillator. JOURNAL OF RADIOTHERAPY IN PRACTICE 2021. [DOI: 10.1017/s1460396921000170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Abstract
Introduction:
An ever-growing number of patients with implantable cardiac rhythm devices are treated with radiation therapy for cancer and are therefore at risk of device failure. Several medical societies developed recommendations for the management of such patients.
We report the case of a 76-year-old patient with an implanted cardioverter defibrillator, treated with external radiotherapy for breast cancer, to test in practice the recommendations on the management of similar cases.
Collapse
|
28
|
Díaz-Gavela AA, Figueiras-Graillet L, Luis ÁM, Salas Segura J, Ciérvide R, del Cerro Peñalver E, Couñago F, Arenas M, López-Fernández T. Breast Radiotherapy-Related Cardiotoxicity. When, How, Why. Risk Prevention and Control Strategies. Cancers (Basel) 2021; 13:1712. [PMID: 33916644 PMCID: PMC8038596 DOI: 10.3390/cancers13071712] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 03/31/2021] [Accepted: 04/02/2021] [Indexed: 12/24/2022] Open
Abstract
In recent decades, improvements in breast cancer management have increased overall patient survival; however, many cancer therapies have been linked to an important risk of cardiovascular adverse events. Cardio-oncology has been proposed as an emerging specialty to coordinate preventive strategies that improve the cardiovascular health of oncologic patients. It employs the most suitable personalized multidisciplinary management approach for each patient to optimize their cardiovascular health and improve their survival and quality of life. Radiotherapy is an essential part of the therapeutic regimen in breast cancer patients but can also increase the risk of cardiovascular disease. Therefore, minimizing the negative impact of radiation therapy is an important challenge for radiotherapy oncologists and cardiologists specializing in this field. The aim of the present review is to update our knowledge about radiation-induced cardiotoxicity in breast cancer patients by undertaking a critical review of the relevant literature to determine risk prevention and control strategies currently available.
Collapse
Affiliation(s)
- Ana Aurora Díaz-Gavela
- Radiation Oncology, Hospital Universitario Quirónsalud Madrid, 28223 Madrid, Spain;
- Radiation Oncology, Hospital La Luz, 28003 Madrid, Spain
- Clinical Department, Faculty of Biomedicine, Universidad Europea de Madrid, 28670 Madrid, Spain
| | - Lourdes Figueiras-Graillet
- Cardiooncology Clinic, Centro Estatal de Cancerología Miguel Dorantes Mesa, Xalapa-Enríquez 91130, Mexico;
| | - Ángel Montero Luis
- Radiation Oncology Department, Hospital Universitario HM Sanchinarro, 28050 Madrid, Spain; (Á.M.L.); (R.C.)
| | - Juliana Salas Segura
- Cardio-oncology Unit, Hospital San Juan de Dios, San José 10103, Costa Rica;
- Cardiology Department, Hospital Clínica Bíblica. San José 10103, Costa Rica
| | - Raquel Ciérvide
- Radiation Oncology Department, Hospital Universitario HM Sanchinarro, 28050 Madrid, Spain; (Á.M.L.); (R.C.)
| | - Elia del Cerro Peñalver
- Radiation Oncology, Hospital Universitario Quirónsalud Madrid, 28223 Madrid, Spain;
- Radiation Oncology, Hospital La Luz, 28003 Madrid, Spain
- Clinical Department, Faculty of Biomedicine, Universidad Europea de Madrid, 28670 Madrid, Spain
| | - Felipe Couñago
- Radiation Oncology, Hospital Universitario Quirónsalud Madrid, 28223 Madrid, Spain;
- Radiation Oncology, Hospital La Luz, 28003 Madrid, Spain
- Clinical Department, Faculty of Biomedicine, Universidad Europea de Madrid, 28670 Madrid, Spain
| | - Meritxell Arenas
- Radiation Oncology, Hospital Universitari Sant Joan de Reus, 43204 Reus, Spain;
- Universitat Rovira i Virgili. IISPV, 43204 Reus, Spain
| | - Teresa López-Fernández
- Cardio-oncology Unit. Cardiology Department, Hospital Universitario La Paz, 28046 Madrid, Spain;
- Hospital La Paz Institute for Health Research—IdiPAZ, 28046 Madrid, Spain
| |
Collapse
|
29
|
Guédon-Moreau L, Finat L, Klein C, Kouakam C, Marquié C, Klug D, Potelle C, Ninni S, Brigadeau F, Mirabel X, Lacroix D. Usefulness of remote monitoring for the early detection of back-up mode in implantable cardioverter defibrillators. Arch Cardiovasc Dis 2021; 114:287-292. [PMID: 33526375 DOI: 10.1016/j.acvd.2020.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 08/07/2020] [Accepted: 11/30/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND Reversion of an implantable cardioverter defibrillator (ICD) to back-up mode degrades the operating capabilities of the device, puts patients at risk and requires rapid intervention by a manufacturer's technician. AIM To illustrate the usefulness of remote monitoring of ICDs for the early detection of reversion to back-up mode. METHODS In our centre, all patients implanted with an ICD, with or without resynchronisation, were offered remote monitoring as soon as the technology became available. Alerts triggered by the remote monitoring system were included prospectively in a register. During a mean follow-up of 5.7±1.3 years, a total of 1594 patients with an ICD (441 with resynchronisation function) followed with remote monitoring were included in the register. RESULTS Among 15,874 alerts, only 10 were related to a reversion to back-up mode. Among those, seven reversions were caused by radiotherapy, two were fake events and one was caused by magnetic resonance imaging. Except for the two fake events, the eight other patients had an emergency admission for the resetting and reprogramming of their ICD. None of the reversion to back-up mode alerts was followed by a clinical alert (i.e. a shock alert) before the ICD problem was resolved. CONCLUSIONS Reversion to back-up mode is a very rare event, accounting for 0.06% of total alerts; remote monitoring facilitates the early detection of this critical event to resolve the problem faster than the next scheduled follow-up. Remote monitoring can prevent serious damage to the patient and avoids systematic ambulatory control of the ICD after each radiotherapy session.
Collapse
Affiliation(s)
- Laurence Guédon-Moreau
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France; Faculty of medicine, Lille university, 59045 Lille, France.
| | - Loïc Finat
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France
| | - Cédric Klein
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France
| | - Claude Kouakam
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France; Centre Oscar-Lambret, Cancer centre, 59000 Lille, France
| | - Christelle Marquié
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France
| | - Didier Klug
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France; Faculty of medicine, Lille university, 59045 Lille, France
| | - Charlotte Potelle
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France
| | - Sandro Ninni
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France; Faculty of medicine, Lille university, 59045 Lille, France
| | - François Brigadeau
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France
| | - Xavier Mirabel
- Centre Oscar-Lambret, Cancer centre, 59000 Lille, France
| | - Dominique Lacroix
- Department of cardiovascular medicine, heart & lung institute, Lille university hospital, 59037 Lille, France; Faculty of medicine, Lille university, 59045 Lille, France
| |
Collapse
|
30
|
Sacher F, Gandjbakhch E, Maury P, Jenny C, Khalifa J, Boveda S, Defaye P, Gras D, Klug D, Laurent G, Lellouche N, Mansourati J, Marijon E, Piot O, Taieb J, Cochet H, Maingon P, Pruvot E, Fauchier L. Focus on stereotactic radiotherapy: A new way to treat severe ventricular arrhythmias? Arch Cardiovasc Dis 2021; 114:140-149. [PMID: 33478860 DOI: 10.1016/j.acvd.2020.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 11/13/2020] [Accepted: 11/16/2020] [Indexed: 02/07/2023]
Abstract
Ventricular tachycardia has a significant recurrence rate after ablation for several reasons, including inaccessible substrate. A non-invasive technique to ablate any defined areas of myocardium involved in arrhythmogenesis would be a potentially important therapeutic improvement if shown to be safe and effective. Early feasibility studies of single-fraction stereotactic body radiotherapy have demonstrated encouraging results, but rigorous evaluation and follow-up are required. In this document, the basic concepts of stereotactic body radiotherapy are summarized, before focusing on stereotactic arrhythmia radioablation. We describe the effect of radioablation on cardiac tissue and its interaction with intracardiac devices, depending on the dose. The different clinical studies on ventricular tachycardia radioablation are analysed, with a focus on target identification, which is the key feature of this approach. Our document ends with the indications and requirements for practicing this type of procedure in 2020. Finally, because of the limited number of patients treated so far, we encourage multicentre registries with long-term follow-up.
Collapse
Affiliation(s)
- Frédéric Sacher
- Department of cardiology, IHU Liryc, electrophysiology and heart modelling institute, Bordeaux university hospital (CHU), university of Bordeaux, 33600 Pessac, France.
| | - Estelle Gandjbakhch
- Department of cardiology, La Pitié-Salpétrière university hospital, AP-HP, 75013 Paris, France
| | - Philippe Maury
- Department of cardiology, Toulouse university hospital, 31059 Toulouse, France
| | - Catherine Jenny
- Department of radiotherapy, La Pitié-Salpétrière university hospital, AP-HP, 75013 Paris, France
| | - Jonathan Khalifa
- Departments of radiotherapy and cardiology, Toulouse university hospital, 31059 Toulouse, France
| | - Serge Boveda
- Department of cardiology, clinique Pasteur, 31076 Toulouse, France
| | - Pascal Defaye
- Department of cardiology, Grenoble university hospital, 38700 La Tronche, France
| | - Daniel Gras
- Department of cardiology, nouvelles cliniques nantaises, 44277 Nantes, France
| | - Didier Klug
- Department of cardiology, Lille university hospital, 59000 Lille, France
| | - Gabriel Laurent
- Department of cardiology, Dijon university hospital, 21000 Dijon, France
| | - Nicolas Lellouche
- Department of cardiology, hôpital Henri-Mondor, AP-HP, 94010 Créteil, France
| | - Jacques Mansourati
- Department of cardiology, Brest university hospital, 29609 Brest, France
| | - Eloi Marijon
- Department of cardiology, hôpital européen Georges-Pompidou, AP-HP, 75015 Paris, France
| | - Olivier Piot
- Department of cardiology, centre cardiologique du nord, 93200 Saint-Denis, France
| | - Jerome Taieb
- Department of cardiology, Aix-en-Provence hospital, 13616 Aix-en-Provence, France
| | - Hubert Cochet
- Department of radiology, IHU Liryc, electrophysiology and heart modelling institute, Bordeaux university hospital (CHU), university of Bordeaux, 33600 Pessac, France
| | - Philippe Maingon
- Department of radiotherapy, La Pitié-Salpétrière university hospital, AP-HP, 75013 Paris, France
| | - Etienne Pruvot
- Department of cardiology, CHUV, 1011 Lausanne, Switzerland
| | - Laurent Fauchier
- Department of cardiology, Tours university hospital, 37000 Tours, France
| | | |
Collapse
|
31
|
Andrianto A, Mulia EPB, Suwanto D, Rachmi DA, Yogiarto M. Case Report: Complete heart block as a manifestation of cardiac metastasis of oral cancer. F1000Res 2020; 9:1243. [PMID: 33274052 PMCID: PMC7682501 DOI: 10.12688/f1000research.26438.2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 11/03/2020] [Indexed: 11/29/2022] Open
Abstract
Metastatic tumors of the heart presenting with complete heart block (CHB) is an extremely uncommon case. There are no available guidelines in managing CHB in terminal cancer. Permanent pacemaker implantation in such cases is a challenge in terms of clinical utility and palliative care. We report a case of a 24-year-old man suffering from tongue cancer presenting with CHB. An intracardiac mass and moderate pericardial effusion were present, presumed as the metastatic tumor of tongue cancer. We implanted a temporary pacemaker for his symptomatic heart block and cardiogenic shock, and pericardiocentesis for his massive pericardial effusion. We decided that a permanent pacemaker would not be implanted based on the low survival rate and significant comorbidities. Multiple studies report a variable number of cardiac metastasis incidence ranging from 2.3% to 18.3%. It is rare for such malignancies to present with CHB. The decision to implant a permanent pacemaker is highly specific based on the risks and benefits of each patient. It needs to be tailored to the patient’s functional status, comorbid diseases, prognosis, and response to conservative management.
Collapse
Affiliation(s)
- Andrianto Andrianto
- Department of Cardiology and Vascular Medicine, Airlangga University - Dr. Soetomo General Hospital, Surabaya, East Java, 60286, Indonesia
| | - Eka Prasetya Budi Mulia
- Department of Cardiology and Vascular Medicine, Airlangga University - Dr. Soetomo General Hospital, Surabaya, East Java, 60286, Indonesia
| | - Denny Suwanto
- Department of Cardiology and Vascular Medicine, Airlangga University - Dr. Soetomo General Hospital, Surabaya, East Java, 60286, Indonesia
| | - Dita Aulia Rachmi
- Department of Cardiology and Vascular Medicine, Airlangga University - Dr. Soetomo General Hospital, Surabaya, East Java, 60286, Indonesia
| | - Mohammad Yogiarto
- Department of Cardiology and Vascular Medicine, Airlangga University - Dr. Soetomo General Hospital, Surabaya, East Java, 60286, Indonesia
| |
Collapse
|
32
|
Ohno T, Soejima T, Sekiguchi Y, Hashimoto T, Koike I, Matsubara H, Nakamura K, Nitta K, Takahashi S, Tsujino K, Wakatsuki M, Yoden E. JASTRO/JCS Guidelines for radiotherapy in patients with cardiac implantable electronic devices. JOURNAL OF RADIATION RESEARCH 2020; 62:172-184. [PMCID: PMC7779359 DOI: 10.1093/jrr/rraa102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 09/19/2020] [Indexed: 06/12/2023]
Abstract
This publication is an English version of the Japanese Society for Radiation Oncology (JASTRO) and The Japanese Circulation Society official guidelines for patients with cardiac implantable electronic devices (CIEDs). Several radiotherapy-associated malfunctions have been reported for CIEDs such as pacemakers and implantable cardioverter-defibrillators. Accordingly, guidelines for radiotherapy in patients with CIEDs have been issued by other countries and societies. In August 2010, JASTRO published the ‘Radiotherapy Guidelines for Patients with Pacemakers and Implantable Defibrillators’ (hereafter referred to as the former guidelines). Given new findings in this decade, a multidisciplinary working group of radiation oncologists, medical physicists, radiation therapists and cardiologists jointly reviewed and revised the former guidelines.
Collapse
Affiliation(s)
- Toshiki Ohno
- Corresponding author. Dokkyo medical University Saitama Medical Center, 2-1-50 Minamikoshigaya, Koshigaya, Saitama, Japan. Tel: +81-282-86-1111;
| | - Toshinori Soejima
- Department of Radiation Oncology, Kobe Proton Center, 1-6-8 Minatojima Minamimachi, Chuo-ku, Kobe 650-0047, Japan
| | - Yukio Sekiguchi
- Department of Cardiology, Faculty of Medicine, University of Tsukuba, Department of Cardiology, 1-1–1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan
| | - Takayuki Hashimoto
- Department of Radiation Medical Science and Engineering, Hokkaido University Faculty of Medicine, Kita 15-jo Nishi 7-chome, Kita-ku, Sapporo 060-8638, Japan
| | - Izumi Koike
- Departments of Radiology, Yokohama City University Graduate School of Medicine, 22-2 Seto, Kanazawa-ku, Yokohama, Kanagawa 236-0027, Japan
| | - Hiroaki Matsubara
- Department of Radiation Oncology, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo 162-8666, Japan
| | - Kazuhiko Nakamura
- Department of Radiology, Aichi Medical University Hospital, 1-1 Yazakokarimata, Nagakute, Aichi 480-1195, Japan
| | - Kazunori Nitta
- Ibaraki Prefectural Central Hospital and Cancer Center, 6528 Koibuchi, Kasama, Ibaraki 309-1793, Japan
| | - Shigeo Takahashi
- Department of Radiation Oncology, Kagawa University Hospital, 1750-1 Ikenobe, Miki-cho, Kita-gun, Kagawa, 761-0793 Japan
| | - Kayoko Tsujino
- Department of Radiation Oncology, Hyogo Cancer Center, 1-2-1 Koto, Shingu-cho, Tatsuno-shi, Hyogo 679-5165, Japan
| | - Masaru Wakatsuki
- Department of Radiology, Jichi medical university, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498, Japan
| | - Eisaku Yoden
- Department of Radiation Oncology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama 701-0192, Japan
| |
Collapse
|
33
|
Kubo T, Iida K, Tamai S. Comparison of Measured Data between Pre- and Post-Radiotherapy in a Patient with Cardiac Resynchronization Therapy Defibrillator. Int Heart J 2020; 61:1311-1314. [PMID: 33191338 DOI: 10.1536/ihj.20-047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Although some researches proved the influence of radiation therapy (RT) on pacemakers and implantable cardioverter defibrillators, little has been reported on cardiac resynchronization therapy defibrillators (CRTDs). We experienced a case of RT on CRTD and had a new finding.A patient with CRTD implanted for dilated cardiomyopathy was diagnosed with lung squamous cell carcinoma and started receiving RT. All the implanted devices, including the main body of CRTD, left ventricular lead (LV), right ventricular lead with high-voltage conductor, and right atrial lead, were from the same manufacturer. The radiation targeted the tumor of 67 mm in diameter in the right superior lobe for 5 min per session. The CRTD was outside the radiation field, which is 65 mm, but the leads were inside. Plan 1 used 2 Gy/fr with 8 megavolt photons, and Plan 1 was irradiated at 0° and 180° for 16 RT sessions. The dosage was increased to 3 Gy for Plan 2 for 4 sessions. Plan 3 used 2 Gy with 6 and 8 megavolt photons, and Plan 3 was irradiated at 27.7° and 200.7° for 11 RT sessions. Changes in measured parameters were assessed before and after RT.Changes in impedance of LV and high-voltage lead exceeded prespecified threshold. However, no significant errors were detected in the CRTD on the dosages and energy we used.We hypothesize that the lead insulator could have been affected by radiation.
Collapse
Affiliation(s)
- Takamitsu Kubo
- Clinical Engineer, Medical Machine and Equipment Management Office, Shizuoka Cancer Center Hospital
| | - Kei Iida
- Division of Cardiology, Shizuoka Cancer Center Hospital
| | - Sunao Tamai
- Division of Anesthesiology, Shizuoka Cancer Center Hospital
| |
Collapse
|
34
|
Gauter-Fleckenstein B, Barthel C, Büttner S, Wenz F, Borggrefe M, Tülümen E. Effectivity and applicability of the German DEGRO/DGK-guideline for radiotherapy in CIED-bearing patients. Radiother Oncol 2020; 152:208-215. [DOI: 10.1016/j.radonc.2020.01.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 12/07/2019] [Accepted: 01/07/2020] [Indexed: 11/26/2022]
|
35
|
Sharifzadehgan A, Laurans M, Thuillot M, Huertas A, Baudinaud P, Narayanan K, Mirabel M, Bibault JE, Frey P, Waldmann V, Varlet E, Amet D, Juin C, Lavergne T, Jouven X, Giraud P, Durdux C, Marijon E. Radiotherapy in Patients With a Cardiac Implantable Electronic Device. Am J Cardiol 2020; 128:196-201. [PMID: 32650920 DOI: 10.1016/j.amjcard.2020.04.045] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 04/20/2020] [Accepted: 04/27/2020] [Indexed: 10/24/2022]
Abstract
Recently, the Heart Rhythm Society published recommendations on management of patients with cardiac implantable electronic device (CIED) who require radiotherapy (RT). We aimed to report the experience of a teaching hospital, and discuss our practice in the context of recently published guidelines. We identified all consecutive CIED recipients (12,736 patients) who underwent RT between March 2006 and June 2017. Among them, 90 (1%) patients (78.2 ± 10 years, 73% male) had a CIED: 82 pacemakers and 8 implantable cardioverter-defibrillators. Two patients required CIED extraction prior to RT for ipsilateral breast cancer (no device replacement in 1 patient). Four patients (5%) were considered at high-risk, 35 (39%) at intermediate-risk, and the remaining 50 (56%) at low-risk for CIED dysfunction. Overall, only a minority of patients followed recommended local protocol during RT delivery (31%) and during follow-up (56%). CIED malfunction was detected in 5 patients (6%), mainly back-up mode resetting (80%), with 4 (including 3 pelvic cancer location) patients initially classified as being at intermediate-risk and 1 at low-risk. Four out of the 5 patients with CEID malfunction had received neutron producing beams. In conclusion, our findings underline the lack of rigorous monitoring of patients undergoing RT (though CIED malfunction appears to be rare and relatively benign in nature), and emphasize the interest of considering neutron producing beam for risk stratification as recommended in recent guidelines. Optimization of patient's management requires a close collaboration between both CIED clinicians and radiation oncologists, and more systematic remote CIED monitoring may be helpful.
Collapse
|
36
|
Falco MD, Genovesi D, Caravatta L, Di Carlo C, Bliakharskaia E, Appignani M, Faustino M, Furia N, Di Girolamo E. A randomized in vitro evaluation of transient and permanent cardiac implantable electronic device malfunctions following direct exposure up to 10 Gy. Strahlenther Onkol 2020; 197:198-208. [PMID: 32561941 DOI: 10.1007/s00066-020-01651-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 06/01/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND AND PURPOSE High-dose 6‑MV radiotherapy may cause cardiac implantable electronic devices (CIEDs) to malfunction. To assess CIED malfunctions resulting from direct exposure up to 10 Gy, 100 pacemakers (PMs) and 40 implantable cardioverter-defibrillators (ICDs) were evaluated. MATERIALS AND METHODS CIEDs underwent baseline interrogation. In ICDs, antitachycardia therapies were disabled via the programmer while the detection windows were left enabled. A computed tomography (CT) scan was performed to build the corresponding treatment plan. CIEDs were "blinded" and randomized to receive single doses of either 2, 5, or, 10 Gy via a 6-MV linear accelerator (linac) in a water phantom. Twenty-two wireless telemetry-enabled CIEDs underwent a real-time session, and their function was recorded by the video camera in the bunker. The CIEDs were interrogated after exposure and once monthly for 6 months. RESULTS During exposure, regardless of dose, 90.9% of the CIEDs recorded electromagnetic interference, with 6 ICDs (27.3%) reporting pacing inhibition and inappropriate arrhythmia detections. After exposure, a backup reset was observed in 1 PM (0.7% overall, 1% among PMs), while 7 PMs (5% overall, 7% among PMs) reported battery issues (overall immediate malfunction rate was 5.7%). During follow-up, 4 PMs (2.9% overall; 4% among PMs) and 1 ICD (0.7% overall; 2.5% among ICDs) reported abnormal battery depletion, and 1 PM (0.7% overall; 1% among PMs) reported a backup reset (overall late malfunction rate was 4.3%). CONCLUSION Apart from transient electromagnetic interference, last-generation CIEDs withstood direct 6‑MV exposure up to 10 Gy. Permanent battery or software errors occurred immediately or later only in less recent CIEDs.
Collapse
Affiliation(s)
- Maria Daniela Falco
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy.
| | - Domenico Genovesi
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy
| | - Luciana Caravatta
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy
| | - Clelia Di Carlo
- Department of Radiation Oncology, "SS. Annunziata" Hospital, "G. D'Annunzio" University, Via De' Vestini, 66100, Chieti, Italy
| | - Ekaterina Bliakharskaia
- Department of Clinical Medicine, Public Health, Life and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| | | | | | - Nanda Furia
- Arrhythmology Unit, "SS. Annunziata" Hospital, Chieti, Italy
| | | |
Collapse
|
37
|
Ramdas Y, Benn CA, Grubnik A, Mayat Y, Holmes DR. Targeted Intraoperative Radiotherapy Is a Safe Approach for Patients with Pacemakers: A Case Study and Literature Review. Case Rep Oncol 2020; 13:916-922. [PMID: 32884540 PMCID: PMC7443642 DOI: 10.1159/000508946] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Accepted: 05/21/2020] [Indexed: 02/03/2023] Open
Abstract
Case reports detailing the effects of targeted intraoperative radiation therapy (IORT) on patients with cardiac pacemakers (PMs) are rare. This growing population sub-group requiring IORT and lack of standardized guidelines necessitate more practical published research. An 81-year-old patient with clinical stage II, T1 N0 grade III, triple-negative invasive ductal carcinoma and an implanted single-lead chamber PM (VVIR mode, model: Biotronik, type Effecta SR) received targeted intraoperative radiotherapy at the time of wide local excision and sentinel lymph node biopsy. It presents the shortest distance between the outer diameter of the PM and IORT applicator in literature. Target IORT was performed utilizing an Intrabeam device (50 kV, Carl Zeiss Surgical, Oberkochen, Germany). This case elucidates the successful use of targeted IORT for breast-conserving surgery in a patient with a single ipsilateral chamber VVIR mode PM. No device failure or malfunction was reported for the PM before, during, or after the procedure. These findings support the use of targeted IORT for patients diagnosed with early-stage breast carcinomas who have a PM implanted. However, further research is needed to understand the safety of other methods and devices for IORT patients with cardiac implantable electronic devices.
Collapse
Affiliation(s)
- Yastira Ramdas
- The Breast Care Unit, NetCare Milpark, Johannesburg, South Africa
| | - Carol-Ann Benn
- The Breast Care Unit, NetCare Milpark, Johannesburg, South Africa
| | | | - Yasmin Mayat
- The Breast Care Unit, NetCare Milpark, Johannesburg, South Africa
| | - Dennis R. Holmes
- Department of Surgery, Glendale Adventist Medical Center, Glendale, California, USA
| |
Collapse
|
38
|
Gimenez De Lorenzo R, Navarra R, Marinelli D, Adorante N, Giancaterino S, Di Carlo C, Di Biase S, Rosa C, Falco MD. Effects of high-energy photon beam radiation therapy on Jarvik 2000 LVAD: in vitro evaluation. Radiol Med 2020; 125:561-568. [PMID: 32067164 DOI: 10.1007/s11547-020-01154-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 02/06/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE Left ventricular assist device (LVAD) is considered a standard care for patients with advanced heart failure. The aim of this work was to study in vitro the effects of direct exposure of the Jarvik 2000 LVAD to 10-MV photon beams. METHODS Jarvik 2000 pump was immersed in a siliconized box filled with deionized water. A 30 × 30 × 15 cm RW3 slabs were added forth and back to the box. A treatment plan consisting of a single direct 10 × 10 cm2 field size beam was used to deliver 1000 MU at the center of the pump. During irradiation, the external Flow Maker controller and the lithium battery were positioned away from the beam. Pump parameter data (included voltage, current and frequency) were measured, recorded and analyzed for changes in pump function among baseline, pre-irradiation, during irradiation, post-irradiation and after 6 months. The whole session lasted 6 months. The Mann-Whitney U test was used to compare the repeated measurements. X-ray radiation attenuation was also studied. RESULTS The parameters investigated remained stable over the 6 months; that is, no pump stops, alarms, events, operational changes or abnormalities during the discharge rate of the connected power sources, were encountered, confirmed by the Mann-Whitney U test applied to all sessions (p > 0.1). The measured X-ray attenuation differed from the calculated one by TPS by 34%. CONCLUSION The Jarvik 2000 resulted stable under direct X-ray beam of 10-MV energy. Its strong attenuation, however, can affect dose deposition in the pump in TPS, and it must be taken into account.
Collapse
Affiliation(s)
- Ramon Gimenez De Lorenzo
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy
| | - Riccardo Navarra
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy.,Department of Neuroimaging and Cognitive Science, University of Chieti "G. D'Annunzio", Chieti, Italy
| | - Daniele Marinelli
- Department of Cardiac Surgery, University of Chieti "G. D'Annunzio", Chieti, Italy
| | - Nico Adorante
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy
| | - Stefano Giancaterino
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy
| | - Clelia Di Carlo
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy
| | - Saide Di Biase
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy
| | - Consuelo Rosa
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy
| | - Maria Daniela Falco
- Department of Radiation Oncology, University of Chieti "G. D'Annunzio", SS. Annunziata Hospital, Chieti, Italy.
| |
Collapse
|
39
|
Wei C, Qian P, Tedrow U, Mak R, Zei PC. Non-invasive Stereotactic Radioablation: A New Option for the Treatment of Ventricular Arrhythmias. Arrhythm Electrophysiol Rev 2020; 8:285-293. [PMID: 32685159 PMCID: PMC7358955 DOI: 10.15420/aer.2019.04] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Ventricular tachycardia (VT) is associated with significant morbidity and mortality. Radiofrequency catheter ablation can be effective for the treatment of VT but it carries a high rate of recurrence often attributable to insufficient depth of penetration for reaching critical arrhythmogenic substrates. Stereotactic body radioablation (SBRT) is a commonly used technology developed for the non-invasive treatment of solid tumours. Recent evidence suggests that it can also be effective for the treatment of VT. It is a non-invasive procedure and it has the unique advantage of delivering ablative energy to any desired volume within the body to reach sites that are inaccessible with catheter ablation. This article summarises the pre-clinical studies that have formed the evidence base for SBRT in the heart, describes the clinical approaches for SBRT VT ablation and provides perspective on next steps for this new treatment modality.
Collapse
Affiliation(s)
- Chen Wei
- Harvard Medical School, Boston, MA, US.,Division of Cardiovascular Medicine, Brigham and Women's Hospital, Boston, MA, US
| | - Pierre Qian
- Division of Cardiovascular Medicine, Brigham and Women's Hospital, Boston, MA, US
| | - Usha Tedrow
- Division of Cardiovascular Medicine, Brigham and Women's Hospital, Boston, MA, US
| | - Raymond Mak
- Department of Radiation Oncology, Brigham and Women's Hospital/Dana-Farber Cancer Institute, Boston, MA, US
| | - Paul C Zei
- Division of Cardiovascular Medicine, Brigham and Women's Hospital, Boston, MA, US
| |
Collapse
|
40
|
Alitto AR, Chiesa S, Franco P, Fiore M, Marino L, Borghetti P, Desideri I, Greto D, Fiorentino A. PAIDEIA: pacemaker and implanted cardioverter defibrillator management in radiation therapy-a survey by the Young Group of the Italian Association of Radiotherapy and Clinical Oncology (AIRO). LA RADIOLOGIA MEDICA 2019; 125:329-335. [PMID: 31832987 DOI: 10.1007/s11547-019-01099-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 10/16/2019] [Indexed: 11/25/2022]
Abstract
INTRODUCTION The management of patients bearing a cardiac implantable electronic device and needing a radiotherapy treatment is an important clinical scenario. The aim of this survey was to evaluate the level of awareness within the Italian Radiation Oncologist community on this topic. MATERIALS AND METHODS A survey was promoted by the Young Group of Italian Association of Radiotherapy and Clinical Oncology (AIRO) with a questionnaire made up of 22 questions allowing for multiple answers, which was administered, both online and on paper version. It was addressed to Radiation Oncologists, AIRO members, participating in the National Congress held in 2015. RESULTS A total of 113 questionnaires were collected back and analyzed (survey online: 50 respondents; paper version: 63). The answers showed a good level of awareness on the issue, but with a nonhomogeneous adherence to the different published guidelines (GL). There is a general low rate of referral for a preliminary cardiological evaluation in patients bearing PM/ICDs, in line with some published surveys; nevertheless, a focused attention to certain specific treatment factors and patient-centered point of view emerged. CONCLUSIONS A generally good awareness of this topic was shown but homogeneous application of GL was not observed, possibly due to the multiplicity of available GL. A prospective data collection could help to better clarify the shadows on this topics.
Collapse
Affiliation(s)
- Anna Rita Alitto
- UOC di Radioterapia Oncologica, Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Silvia Chiesa
- UOC di Radioterapia Oncologica, Dipartimento Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
| | - Pierfrancesco Franco
- Dipartimento di Oncologia - Radioterapia Oncologica, Università di Torino - AOU Citta' della Salute e della Scienza, Turin, Italy
| | - Michele Fiore
- Radioterapia Oncologica, Policlinico Universitario Campus Biomedico, Rome, Italy
| | | | - Paolo Borghetti
- Dipartimento di Radioterapia Oncologica, Università e ASST Spedali Civili di Brescia, Brescia, Italy
| | - Isacco Desideri
- Dipartimento di Scienze Biomediche Sperimentali e Cliniche Mario Serio, Radioterapia Oncologica, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Daniela Greto
- Dipartimento di Scienze Biomediche Sperimentali e Cliniche Mario Serio, Radioterapia Oncologica, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Alba Fiorentino
- Dipartimento di Radioterapia Oncologica, Ospedale Generale Regionale "F. Miulli", Acquaviva Delle Fonti, Bari, Italy
| |
Collapse
|
41
|
Radiation Therapy–Induced Dysfunction in Cardiovascular Implantable Electronic Devices. Pract Radiat Oncol 2019; 9:266-273. [DOI: 10.1016/j.prro.2019.03.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 02/28/2019] [Accepted: 03/13/2019] [Indexed: 11/18/2022]
|
42
|
Abstract
PURPOSE OF REVIEW With the rapid development of novel cancer therapeutics and the growing number of cancer survivors, there is significant demand for cardio-oncology experts to care for these patients. As such, it has become increasingly necessary to develop formalized training in the field of cardio-oncology. This review will focus on the current state of cardio-oncology education, with recommendations for the development of dedicated cardio-oncology fellowships. RECENT FINDINGS Cardio-oncology fellowships should be affiliated with high-volume centers that have established cardio-oncology clinical and research programs with dedicated cardio-oncology faculty. Several recent publications have proposed recommendations to develop uniform cardio-oncology training standards, core curricula, and evaluation metrics. With the rapid evolution of the field and the support of various profession organizations, the number and quality of dedicated cardio-oncology fellowship programs is expected to increase significantly. The adoption of defined training requirements and evaluation standards to measure competency will be essential to ensure the legitimacy and success of the field.
Collapse
Affiliation(s)
- Michael G Fradley
- Cardio-Oncology Program, Division of Cardiovascular Medicine, Morsani College of Medicine and H. Lee Moffitt Cancer Center and Research Institute, University of South Florida, 12902 USF Magnolia Dr., MCB-CPT, Tampa, FL, 33612-9416, USA.
| |
Collapse
|
43
|
A review and analysis of stereotactic body radiotherapy and radiosurgery of patients with cardiac implantable electronic devices. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:415-425. [DOI: 10.1007/s13246-019-00751-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Accepted: 03/27/2019] [Indexed: 10/27/2022]
|
44
|
Radiotherapy for patients with cardiovascular implantable electronic devices: an 11-year experience. J Interv Card Electrophysiol 2019; 55:333-341. [PMID: 30603854 DOI: 10.1007/s10840-018-0506-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 12/17/2018] [Indexed: 10/27/2022]
Abstract
PURPOSE As cardiovascular implantable electronic devices (CIEDs) are increasingly indicated in older patients, and the burden of cancer is rising with the aging population, the management of patients with CIEDs who require radiotherapy (RT) is a timely concern. The objective of the study was to evaluate the management of, and malfunctions in, patients with CIEDs undergoing RT. METHODS A retrospective study of patients with CIEDs receiving RT at Kingston Health Sciences Center from March 2007-April 2018 was conducted. Data on demographics, RT, devices, and management were compared for the primary outcome of device malfunction. RESULTS Of the 189 patients with CIEDs receiving a total of 297 courses of RT, 4 patients (2.1%) experienced device malfunctions. Higher beam energy was associated with a malfunction (p < 0.05). Patients with malfunctions received a lower dose of radiation per fraction (267 ± 93 cGy vs. 477 ± 282 cGy; p < 0.05) and were significantly younger (71.4 ± 2.2 years vs. 77.8 ± 9.8 years; p < 0.01) compared to patients without malfunctions. CONCLUSION RT-induced device malfunctions are rare, but given the potential complications, a better understanding of the potential predictors of malfunction and the development of evidence-based guidelines will help optimize patient safety.
Collapse
|
45
|
Johar S, Luqman N. Initial experience with a leadless pacemaker (Micra™) implantation in a low volume center in South East Asia. Future Cardiol 2018; 14:389-395. [PMID: 30251546 PMCID: PMC6190239 DOI: 10.2217/fca-2017-0106] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Aim: The Micra™ Transcatheter Pacing System is a leadless pacemaker that has been introduced recently. We share our experience in a low volume center and the use of right ventricular angiography (RVA) during implantation. Materials & methods: Patients underwent Micra implantation and RVA was performed to predetermine the implant site. Results: Nine patients underwent Micra implantation. The most common indication was atrial fibrillation with bradycardia. The device was implanted at apical-septum in seven and mid-septum in two. The procedure time ranged from 30 to 100 min and fluoroscopic time 4–18 min. Pacing parameters remained stable after 1-month follow-up. Conclusion: The Micra implantation technique can be easily learnt. RVA was helpful in selecting an appropriate site for the Micra implant.
Collapse
Affiliation(s)
- Sofian Johar
- Consultant Cardiologist & Electrophysiologist, Gleneagles JPMC & Cardiac Centre RIPAS Hospital, Bander Seri Begawan BA1710, Brunei Darussalam
| | - Nazar Luqman
- Consultant Cardiologist, Cardiac Centre RIPAS Hospital, Bander Seri Begawan BA1710, Brunei Darussalam
| |
Collapse
|
46
|
Dosimetric study to assess the feasibility of intraoperative radiotherapy with electrons (ELIOT) as partial breast irradiation for patients with cardiac implantable electronic device (CIED). Breast Cancer Res Treat 2018; 171:693-699. [PMID: 29978418 DOI: 10.1007/s10549-018-4878-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 07/02/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE To report in-vivo dosimetry in the infraclavicular region, a potential site of a cardiac implantable electronic device (CIED) and to evaluate the absorbed dose from intraoperative radiotherapy with electrons (ELIOT). METHODS 27 non-cardiopathic breast cancer (BC) patients without CIED received quadrantectomy and ELIOT as partial breast irradiation. Before delivering ELIOT, two catheters, each containing eight thermoluminescent dosimeters (TLDs), were positioned in the infraclavicular region. TLDs internal catheter was located deep in the tumor bed while the external catheter was placed on patient's skin. RESULTS Data were available for 24/27 patients. The absorbed doses were referred to the dose of 21 Gy. Values measured by the external catheter were low, although statistically significant higher doses were found close to the applicator (mean values 0.26-0.49 Gy). External TLD doses in proximity of the applicator were lower than those detected by their internal counterparts. Values measured by the internal catheter TLDs varied according to the distance from the applicator while no correlation with tumor site and beam energy was found. The distance from the applicator to deliver < 2 Gy to a CIED was 2 cm, while from 2.5 cm the dose measured in all the patients became negligible. CONCLUSIONS This dosimetric study provided data to support the clinical use of ELIOT in BC patients having CIEDs as long as the suggested minimum safe distance of 2.5 cm is taken from the RT field in case of ELIOT single dose of 21 Gy, in the energy range of 6-10 MeV.
Collapse
|
47
|
Lenarczyk R, Potpara TS, Haugaa KH, Deharo JC, Hernandez-Madrid A, Del Carmen Exposito Pineda M, Kiliszek M, Dagres N. Approach to cardio-oncologic patients with special focus on patients with cardiac implantable electronic devices planned for radiotherapy: results of the European Heart Rhythm Association survey. Europace 2018; 19:1579-1584. [PMID: 28934410 DOI: 10.1093/europace/eux195] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2017] [Accepted: 07/07/2017] [Indexed: 11/14/2022] Open
Abstract
The aim of this European Heart Rhythm Association (EHRA) survey was to evaluate clinical practice regarding cardio-oncologic patients, with special focus on patients with cardiac implantable electronic devices (CIEDs) planned for anticancer radiotherapy (RT), among members of the EHRA electrophysiology research network. Of the 36 responding centres, 89% managed patients who were diagnosed or treated oncologically, and this diagnosis affected 1-5% of cardiovascular patients in majority of centres (57%). The main side effects of anticancer therapy in patients treated by cardiologists were thromboembolic complications and left ventricular dysfunction (both reported as 'frequent' by 43% of the centres). The main agents associated with complications were anthracyclines, RT, and monoclonal antibodies. Echocardiography was the most common method of screening for cardiovascular complications (93%), and 10% of the centres did not routinely screen for treatment-induced cardiotoxicity. Opinions on the safe radiation dose, methods of device shielding, and risk calculation prior to RT in CIED patients differed among centres. Precaution measures in high-risk CIED patients were very heterogeneous among centres. Our survey has shown that the awareness of cardiac consequences of anticancer therapy is high, despite relatively low proportion of patients treated oncologically among all cardiovascular patients. There is a consensus of which screening methods should be used for cardiotoxicity of anticancer treatment, but the apprehension of screening necessity is low. Methods of risk assessment and safety measures in CIED patients undergoing RT are very heterogeneous among the European centres, underscoring the need for standardization of the approach to cardio-oncologic patients.
Collapse
Affiliation(s)
- Radoslaw Lenarczyk
- Department of Cardiology, Congenital Heart Disease and Electrotherapy, Silesian Medical University, Silesian Centre for Heart Diseases, Curie-Sklodowskiej Str 9, 41-800 Zabrze, Poland
| | - Tatjana S Potpara
- School of Medicine, University of Belgrade, dr Subotica 8, 11000 Belgrade, Serbia.,Cardiology Clinic, Clinical Centre of Serbia, Visegradska 26, 11000 Belgrade, Serbia
| | - Kristina H Haugaa
- Department of Cardiology and Institute for Surgical Research, Center for Cardiological Innovation, Oslo University Hospital, Rikshospitalet, Postboks 4950 Nydalen, 0424 Oslo, Norway.,Insitute for Clinical Medicine, University of Oslo, 0313 Oslo, Norway
| | - Jean-Claude Deharo
- Service de Cardiologie, Hôpital Timone Adultes, 264 Rue Saint-Pierre, 13385 Marseille, France
| | | | - Maria Del Carmen Exposito Pineda
- Cardiac Electrophysiology, Hospital Universitario Son Espases in Palma de Mallorca, Carr. de Valldemossa, 79, 07120 Palma, Islas Baleares, Spain
| | - Marek Kiliszek
- Departament of Cardiology and Internal Diseases, Military Institute of Medicine, Szaserów Str 128, 04-141 Warsaw, Poland
| | - Nikolaos Dagres
- Department of Electrophysiology, Heart Center Leipzig, Strümpellstr. 39, 04289 Leipzig, Germany
| |
Collapse
|
48
|
Zecchin M, Artico J, Morea G, Severgnini M, Bianco E, De Luca A, Fantasia AZ, Salvatore L, Milan V, Lucarelli M, Dissegna R, Cannatà A, Sinagra G. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions. J Cardiovasc Med (Hagerstown) 2018; 19:155-160. [DOI: 10.2459/jcm.0000000000000623] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
49
|
Yeung C, Chacko S, Glover B, Campbell D, Crystal E, Ben-Dov N, Baranchuk A. Radiotherapy for Patients with Cardiovascular Implantable Electronic Devices: A Review. Can J Cardiol 2017; 34:244-251. [PMID: 29395701 DOI: 10.1016/j.cjca.2017.11.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2017] [Revised: 11/28/2017] [Accepted: 11/29/2017] [Indexed: 11/16/2022] Open
Abstract
Because cardiovascular implantable electronic devices are increasingly indicated in older patients, and the burden of cancer is rising with the growth and aging of the world population, the management of patients with cardiac devices who require radiotherapy for cancer treatment is a timely concern. Device malfunctions might occur in as high as 3% of radiotherapy courses, posing a substantial issue in clinical practice. A nonsystematic comprehensive review was undertaken. We searched PubMed and the MEDLINE database for randomized controlled trials, meta-analyses, systematic reviews, observational studies, in vitro/in vivo studies, and case reports. Articles were selected by 2 independent reviewers, and emphasis was given to information of interest to a general medical readership. The pathophysiology and predictors of cardiovascular implantable electronic device malfunction due to radiotherapy are reviewed, recommendations for the management of patients with such devices undergoing radiotherapy are summarized, and the clinical significance and future directions of this field are discussed. Radiotherapy-induced device malfunctions are rare, but because of the potential complications, the development of evidence-based guidelines for the management of patients with cardiovascular implantable electronic devices undergoing radiotherapy is a timely concern.
Collapse
Affiliation(s)
- Cynthia Yeung
- Heart Rhythm Service, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada
| | - Sanoj Chacko
- Heart Rhythm Service, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada
| | - Benedict Glover
- Heart Rhythm Service, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada
| | - Debra Campbell
- Heart Rhythm Service, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada
| | - Eugene Crystal
- Arrhythmia Services, Schulich Heart Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Nissan Ben-Dov
- Arrhythmia Services, Schulich Heart Centre, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Adrian Baranchuk
- Heart Rhythm Service, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada.
| |
Collapse
|
50
|
Ezzati AO, Studenski MT. Neutron damage induced in cardiovascular implantable electronic devices from a clinical 18 MV photon beam: A Monte Carlo study. Med Phys 2017; 44:5660-5666. [DOI: 10.1002/mp.12581] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Revised: 07/27/2017] [Accepted: 09/01/2017] [Indexed: 11/06/2022] Open
Affiliation(s)
- Ahad Ollah Ezzati
- Department of Physics; University of Tabriz; 29 Bahman Blvd. Tabriz 5166616471 Iran
| | - Matthew T. Studenski
- Department of Radiation Oncology; University of Miami; 1475 NW 12 Ave. Suite 1500 Miami FL 33136 USA
| |
Collapse
|