1
|
Abstract
Clinical and environmental analyses frequently necessitate rapid, simple, and inexpensive point-of-care or field tests. These semiquantitative tests may be later followed up by confirmatory laboratory-based assays, but provide an initial scenario assessment important for resource mobilization and threat confinement. Lateral-flow assays (LFAs) and dip-stick assays, which are typically antibody-based and yield a visually detectable signal, provide an assay format suiting these applications extremely well. Signal generation is commonly obtained through the use of colloidal gold or latex beads, which yield a colored band either directly proportional or inversely proportional to the concentration of the analyte of interest. Here, dye-encapsulating liposomes as a highly visible alternative are discussed. The semiquantitative LFA biosensor described in this chapter relies on a sandwich immunoassay for the detection of myoglobin in whole blood. After an acute myocardial infarction (AMI) event, several cardiac markers are released into the blood, the most common of which are troponin, creatine kinase MB, C-reactive protein, and myoglobin. Due to its early release, myoglobin has value as an indicator of a recent heart attack amongst conditions which present with similar symptoms and its lack of elevation can effectively rule out a heart attack (Brogan et al., Ann Emerg Med 24:665-671, 1994). The assay described within relies on sandwich complex formation between a membrane immobilized capture monoclonal antibody against myoglobin, a detector biotinylated monoclonal antibody against a different epitope on myoglobin, and streptavidin-conjugated visible dye (sulforhodamine B)-encapsulating liposomes to allow for signal generation.
Collapse
Affiliation(s)
- Katie A Edwards
- Department of Biological and Environmental Engineering, Cornell University, 140 Riley-Robb Hall, Ithaca, NY, 14853, USA
| | - Ricki Korff
- Department of Biological and Environmental Engineering, Cornell University, 140 Riley-Robb Hall, Ithaca, NY, 14853, USA
| | - Antje J Baeumner
- Department of Biological and Environmental Engineering, Cornell University, 140 Riley-Robb Hall, Ithaca, NY, 14853, USA.
- Institute for Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93040, Regensburg, Germany.
| |
Collapse
|
2
|
Hara-Kudo Y, Konishi N, Ohtsuka K, Iwabuchi K, Kikuchi R, Isobe J, Yamazaki T, Suzuki F, Nagai Y, Yamada H, Tanouchi A, Mori T, Nakagawa H, Ueda Y, Terajima J. An interlaboratory study on efficient detection of Shiga toxin-producing Escherichia coli O26, O103, O111, O121, O145, and O157 in food using real-time PCR assay and chromogenic agar. Int J Food Microbiol 2016; 230:81-8. [PMID: 27153219 DOI: 10.1016/j.ijfoodmicro.2016.03.031] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2015] [Revised: 03/21/2016] [Accepted: 03/31/2016] [Indexed: 11/28/2022]
Abstract
To establish an efficient detection method for Shiga toxin (Stx)-producing Escherichia coli (STEC) O26, O103, O111, O121, O145, and O157 in food, an interlaboratory study using all the serogroups of detection targets was firstly conducted. We employed a series of tests including enrichment, real-time PCR assays, and concentration by immunomagnetic separation, followed by plating onto selective agar media (IMS-plating methods). This study was particularly focused on the efficiencies of real-time PCR assays in detecting stx and O-antigen genes of the six serogroups and of IMS-plating methods onto selective agar media including chromogenic agar. Ground beef and radish sprouts samples were inoculated with the six STEC serogroups either at 4-6CFU/25g (low levels) or at 22-29CFU/25g (high levels). The sensitivity of stx detection in ground beef at both levels of inoculation with all six STEC serogroups was 100%. The sensitivity of stx detection was also 100% in radish sprouts at high levels of inoculation with all six STEC serogroups, and 66.7%-91.7% at low levels of inoculation. The sensitivity of detection of O-antigen genes was 100% in both ground beef and radish sprouts at high inoculation levels, while at low inoculation levels, it was 95.8%-100% in ground beef and 66.7%-91.7% in radish sprouts. The sensitivity of detection with IMS-plating was either the same or lower than those of the real-time PCR assays targeting stx and O-antigen genes. The relationship between the results of IMS-plating methods and Ct values of real-time PCR assays were firstly analyzed in detail. Ct values in most samples that tested negative in the IMS-plating method were higher than the maximum Ct values in samples that tested positive in the IMS-plating method. This study indicates that all six STEC serogroups in food contaminated with more than 29CFU/25g were detected by real-time PCR assays targeting stx and O-antigen genes and IMS-plating onto selective agar media. Therefore, screening of stx and O-antigen genes followed by isolation of STECs by IMS-plating methods may be an efficient method to detect the six STEC serogroups.
Collapse
Affiliation(s)
- Yukiko Hara-Kudo
- Division of Microbiology, National Institute of Health Sciences, 1-18-1 Kamiyoga, Setagaya, Tokyo 158-8501, Japan.
| | - Noriko Konishi
- Tokyo Metropolitan Institute of Public Health, 3-24-1, Hyakunin-cho, Shinjuku, Tokyo 169-0073, Japan
| | - Kayoko Ohtsuka
- Saitama Institute of Public Health, 410-1, Ewai, Yoshimi-machi, Hiki-gun, Saitama 355-0133, Japan
| | - Kaori Iwabuchi
- Research Institute for Environmental Sciences and Public Health of Iwate Prefecture, 1-11-16, Kitaiioka, Morioka 020-0857, Japan
| | - Rie Kikuchi
- Fukushima Institute for Public Health, 16-6, Mitouchi, Houkida, Fukushima 960-8560, Japan
| | - Junko Isobe
- Toyama Institute of Health, 17-1, Nakataikouyama, Imizu 939-0363, Japan
| | - Takumiko Yamazaki
- Suginami City Institute of the Public Health, 3-20-3, Takaidohigashi, Suginami, Tokyo 168-0072, Japan
| | - Fumie Suzuki
- Shizuoka City Institute of Environmental Sciences and Public Health, 1-4-7, Oguro, Suruga, Shizuoka 422-8072, Japan
| | - Yuhki Nagai
- Mie Prefecture Health and Environment Research Institute, 3684-11, Sakura-cho, Yokkaichi 512-1211, Japan
| | - Hiroko Yamada
- Hiroshima Prefectural Technology Research Institute, Public Health and Environment Center, 1-6-29, Minami-machi, Minami, Hiroshima 734-0007, Japan
| | - Atsuko Tanouchi
- Hiroshima City Institute of Public Health, 4-1-2, Shoko-Center, Nishi, Hiroshima 733-8650, Japan
| | - Tetsuya Mori
- Institute for Food and Environment Sciences Tokyo Kenbikyo-in Foundation, 4F, 5-1, Toyomi-cho, Chuo, Tokyo 104-0055, Japan
| | - Hiroshi Nakagawa
- BML Food Science Solutions, Inc., 1491, Matoba, Kawagoe 350-1101, Japan
| | - Yasufumi Ueda
- Center of Inspection of Imported Foods and Infectious Diseases, Kobe Quarantine Station, 1-1, Toyahama-cho, Hyogo, Kobe 652-0866, Japan
| | - Jun Terajima
- Division of Microbiology, National Institute of Health Sciences, 1-18-1 Kamiyoga, Setagaya, Tokyo 158-8501, Japan
| |
Collapse
|
3
|
Terao Y, Takeshita K, Nishiyama Y, Morishita N, Matsumoto T, Morimatsu F. Promising Nucleic Acid Lateral Flow Assay Plus PCR for Shiga Toxin-Producing Escherichia coli. J Food Prot 2015; 78:1560-8. [PMID: 26219371 DOI: 10.4315/0362-028x.jfp-14-495] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Shiga toxin (Stx)-producing Escherichia coli (STEC) is a frequent cause of foodborne infections, and methods for rapid and reliable detection of STEC are needed. A nucleic acid lateral flow assay (NALFA) plus PCR was evaluated for detecting STEC after enrichment. When cell suspensions of 45 STEC strains, 14 non-STEC strains, and 13 non-E. coli strains were tested with the NALFA plus PCR, all of the STEC strains yielded positive results, and all of the non-STEC and non-E. coli strains yielded negative results. The lower detection limit for the STEC strains ranged from 0.1 to 1 pg of genomic DNA (about 20 to 200 CFU) per test, and the NALFA plus PCR was able to detect Stx1- and Stx2-producing E. coli strains with similar sensitivities. The ability of the NALFA plus PCR to detect STEC in enrichment cultures of radish sprouts, tomato, raw ground beef, and beef liver inoculated with 10-fold serially diluted STEC cultures was comparable to that of a real-time PCR assay (at a level of 100 to 100,000 CFU/ml in enrichment culture). The bacterial inoculation test in raw ground beef revealed that the lower detection limit of the NALFA plus PCR was also comparable to that obtained with a real-time PCR assay that followed the U.S. Department of Agriculture guidelines. Although further evaluation is required, these results suggest that the NALFA plus PCR is a specific and sensitive method for detecting STEC in a food manufacturing plant.
Collapse
Affiliation(s)
- Yoshitaka Terao
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan.
| | - Kana Takeshita
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Yasutaka Nishiyama
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Naoki Morishita
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Takashi Matsumoto
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| | - Fumiki Morimatsu
- R&D Center, NH Foods Ltd., 3-3 Midorigahara, Tsukuba, Ibaraki 300-2646, Japan
| |
Collapse
|
4
|
Posthuma-Trumpie GA, Wichers JH, Koets M, Berendsen LBJM, van Amerongen A. Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays. Anal Bioanal Chem 2012; 402:593-600. [PMID: 21904801 PMCID: PMC3249172 DOI: 10.1007/s00216-011-5340-5] [Citation(s) in RCA: 89] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2011] [Revised: 08/13/2011] [Accepted: 08/15/2011] [Indexed: 12/16/2022]
Abstract
Carbon nanoparticles (CNPs) labeled with reporter molecules can serve as signaling labels in rapid diagnostic assays as an alternative to gold, colored latex, silica, quantum dots, or up-converting phosphor nanoparticles. Detailed here is the preparation of biomolecule-labeled CNPs and examples of their use as a versatile label. CNPs can be loaded with a range of biomolecules, such as DNA, antibodies, and proteins (e.g., neutravidin or a fusion protein of neutravidin with an enzyme), and the resulting conjugates can be used to detect analytes of high or low molecular mass.
Collapse
Affiliation(s)
| | - Jan H. Wichers
- Food and Biobased Research, Wageningen University and Research Centre, P.O. Box 17, 6700 AA Wageningen, The Netherlands
| | - Marjo Koets
- Food and Biobased Research, Wageningen University and Research Centre, P.O. Box 17, 6700 AA Wageningen, The Netherlands
| | - Luciënne B. J. M. Berendsen
- Food and Biobased Research, Wageningen University and Research Centre, P.O. Box 17, 6700 AA Wageningen, The Netherlands
| | - Aart van Amerongen
- Food and Biobased Research, Wageningen University and Research Centre, P.O. Box 17, 6700 AA Wageningen, The Netherlands
| |
Collapse
|
5
|
Principato M, Njoroge JM, Perlloni A, Donnell MO, Boyle T, Jones Jr RL. Detection of Target Staphylococcal Enterotoxin B Antigen in Orange Juice and Popular Carbonated Beverages Using Antibody-Dependent Antigen-Capture Assays. J Food Sci 2010; 75:T141-7. [DOI: 10.1111/j.1750-3841.2010.01806.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
6
|
Brunt J, Webb MD, Peck MW. Rapid affinity immunochromatography column-based tests for sensitive detection of Clostridium botulinum neurotoxins and Escherichia coli O157. Appl Environ Microbiol 2010; 76:4143-50. [PMID: 20435757 PMCID: PMC2897428 DOI: 10.1128/aem.03059-09] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2009] [Accepted: 04/23/2010] [Indexed: 11/20/2022] Open
Abstract
Existing methods for detection of food-borne pathogens and their toxins are frequently time-consuming, require specialized equipment, and involve lengthy culture procedures and/or animal testing and are thus unsuitable for a rapid response to an emergency public health situation. A series of simple and rapid affinity immunochromatography column (AICC) assays were developed to detect Clostridium botulinum neurotoxin types A, B, E, and F and Escherichia coli O157 in food matrices. Specifically, for milk, grape juice with peach juice, and bottled water, the detection limit for the botulinum neurotoxin type A complex was 0.5 ng. Use of this method with a 10-ml sample would therefore result in a detection limit of 50 pg ml(-l). Thus, this assay is approximately 2 orders of magnitude more sensitive than a comparable lateral-flow assay. For botulinum neurotoxin complex types B, E, and F, the minimum detection limit was 5 ng to 50 ng. Sensitive detection of E. coli O157 was achieved, and the detection limit was 500 cells. The AICC test was also shown to be specific, rapid, and user friendly. This test takes only 15 to 30 min to complete without any specialized equipment and thus is suitable for use in the field. It has the potential to replace existing methods for presumptive detection of botulinum neurotoxin types A, B, E, and F and E. coli O157 in contaminated matrices without a requirement for preenrichment.
Collapse
Affiliation(s)
- Jason Brunt
- Institute of Food Research, Norwich Research Park, Colney, Norwich NR4 7UA, United Kingdom.
| | | | | |
Collapse
|
7
|
Meng XM, Yu SY, Lu SY, Ren HL, Li YS, Zhou Y, Liu ZS. Preparation and Immunological Characteristics of Broad-Spectrum Antibodies Against Poly-Recombinant Toxins from Food-Borne Pathogenic Bacteria. FOOD BIOTECHNOL 2009. [DOI: 10.1080/08905430902873445] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
8
|
Edwards KA, Baeumner AJ. Liposome-enhanced lateral-flow assays for the sandwich-hybridization detection of RNA. Methods Mol Biol 2009; 504:185-215. [PMID: 19159099 DOI: 10.1007/978-1-60327-569-9_13] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Clinical and environmental analyses frequently necessitate rapid, simple, and inexpensive point-of-care or field tests. These semiquantitative tests may be later followed up by confirmatory laboratory-based assays, but can provide an initial scenario assessment important for resource mobilization and threat confinement. Lateral-flow assays (LFAs) and dip-stick assays, which are typically antibody-based and yield a visually detectable signal, provide an assay format suiting these applications extremely well. Signal generation is commonly obtained through the use of colloidal gold or latex beads, which yield a colored band either directly proportional or inversely proportional to the concentration of the analyte of interest. Here, dye-encapsulating liposomes as an alternative are discussed. The LFA biosensors described in this chapter rely on the sandwich-hybridization of a nucleic acid sequence-based amplified (NASBA) mRNA target between a membrane immobilized capture probe and a visible dye (sulforhodamine B)-encapsulating liposome conjugated reporter probe. Although the methodology of this chapter is focused on LFAs for the detection of RNA through sandwich hybridization, the information within can be readily adapted for sandwich and competitive immunoassays. Included are an introduction and application notes toward this end. These include notes ranging from the detection of nonamplified RNA and single-stranded DNA, conjugation protocols for antibodies and other proteins to liposomes, and universal assay formats.
Collapse
Affiliation(s)
- Katie A Edwards
- Department of Biological and Environmental Engineering, Cornell University, Ithaca, NY, USA
| | | |
Collapse
|
9
|
Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey. Anal Bioanal Chem 2008; 393:569-82. [PMID: 18696055 DOI: 10.1007/s00216-008-2287-2] [Citation(s) in RCA: 947] [Impact Index Per Article: 59.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2008] [Revised: 07/01/2008] [Accepted: 07/03/2008] [Indexed: 10/21/2022]
Abstract
Lateral flow (immuno)assays are currently used for qualitative, semiquantitative and to some extent quantitative monitoring in resource-poor or non-laboratory environments. Applications include tests on pathogens, drugs, hormones and metabolites in biomedical, phytosanitary, veterinary, feed/food and environmental settings. We describe principles of current formats, applications, limitations and perspectives for quantitative monitoring. We illustrate the potentials and limitations of analysis with lateral flow (immuno)assays using a literature survey and a SWOT analysis (acronym for "strengths, weaknesses, opportunities, threats"). Articles referred to in this survey were searched for on MEDLINE, Scopus and in references of reviewed papers. Search terms included "immunochromatography", "sol particle immunoassay", "lateral flow immunoassay" and "dipstick assay".
Collapse
|
10
|
Grif K, Orth D, Dierich MP, Würzner R. Comparison of an immunochromatographic rapid test with enzyme-linked immunosorbent assay and polymerase chain reaction for the detection of Shiga toxins from human stool samples. Diagn Microbiol Infect Dis 2007; 59:97-9. [PMID: 17532589 DOI: 10.1016/j.diagmicrobio.2007.03.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2006] [Revised: 03/26/2007] [Accepted: 03/26/2007] [Indexed: 10/23/2022]
Abstract
Rapid detection of enterohemorrhagic Escherichia coli is important for its successful treatment. We have evaluated the immunochromatographic Duopath Verotoxin-test for detection of Shiga toxins, in comparison with enzyme-linked immunosorbent assay and polymerase chain reaction, on 240 clinical human stool samples. The Duopath-test showed a lower sensitivity and specificity.
Collapse
Affiliation(s)
- Katharina Grif
- Department of Hygiene, Microbiology and Social Medicine, Innsbruck Medical University, Austrian Reference Centre for Enterohemorrhagic Escherichia coli, A-6020 Innsbruck, Austria.
| | | | | | | |
Collapse
|
11
|
Liu WC, Shaw DJ, Matthews L, Hoyle DV, Pearce MC, Yates CM, Low JC, Amyes SGB, Gunn GJ, Woolhouse MEJ. Modelling the epidemiology and transmission of Verocytotoxin-producing Escherichia coli serogroups O26 and O103 in two different calf cohorts. Epidemiol Infect 2007; 135:1316-23. [PMID: 17224085 PMCID: PMC2870690 DOI: 10.1017/s0950268806007722] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Mathematical models are constructed to investigate the population dynamics of Verocytotoxin-producing Escherichia coli (VTEC) serogroups O26 and O103 in two different calf cohorts. We compare the epidemiological characteristics of these two serogroups within the same calf cohort as well as the same serogroups between the two calf cohorts. The sources of infection are quantified for both calf cohort studies. VTEC serogroups O26 and O103 mainly differ in the rate at which calves acquire infection from sources other than infected calves, while infected calves typically remain infectious for less than 1 week regardless of the serogroups. Fewer than 20% of VTEC-positive samples are the result of calf-to-calf transmission. PFGE typing data are available for VTEC-positive samples to further subdivide the serogroup data in one of the two calf cohort studies. For serogroup O26 but not O103, there is evidence for unequal environmental exposure to infection with different PFGE types.
Collapse
Affiliation(s)
- W-C Liu
- Centre for Infectious Diseases, College of Medicine and Veterinary Medicine, University of Edinburgh, Midlothian, UK.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Bohaychuk VM, Gensler GE, King RK, Wu JT, McMullen LM. Evaluation of detection methods for screening meat and poultry products for the presence of foodborne pathogens. J Food Prot 2005; 68:2637-47. [PMID: 16355836 DOI: 10.4315/0362-028x-68.12.2637] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Rapid and molecular technologies such as enzyme-linked immunosorbent assay (ELISA), PCR, and lateral flow immunoprecipitation can reduce the time and labor involved in screening food products for the presence of pathogens. These technologies were compared with conventional culture methodology for the detection of Salmonella, Campylobacter, Listeria, and Escherichia coli O157:H7 inoculated in raw and processed meat and poultry products. Recommended protocols were modified so that the same enrichment broths used in the culture methods were also used in the ELISA, PCR, and lateral flow immunoprecipitation assays. The percent agreement between the rapid technologies and culture methods ranged from 80 to 100% depending on the pathogen detected and the method used. ELISA, PCR, and lateral flow immunoprecipitation all performed well, with no statistical difference, compared with the culture method for the detection of E. coli O157:H7. ELISA performed better for the detection of Salmonella, with sensitivity and specificity rates of 100%. PCR performed better for the detection of Campylobacter jejuni, with 100% agreement to the culture method. PCR was highly sensitive for the detection of all the foodborne pathogens tested except Listeria monocytogenes. Although the lateral flow immunoprecipitation tests were statistically different from the culture methods for Salmonella and Listeria because of false-positive results, the tests did not produce any false negatives, indicating that this method would be suitable for screening meat and poultry products for these pathogens.
Collapse
Affiliation(s)
- Valerie M Bohaychuk
- Agri-Food Laboratories Branch, Food Safety Division, Alberta Agriculture, Food and Rural Development, 6909 116 Street, Edmonton, Alberta, Canada.
| | | | | | | | | |
Collapse
|