Criscuolo ER, Hao Y, Zhang Z, McKeown T, Yang D. A Vessel Bifurcation Landmark Pair Dataset for Abdominal CT Deformable Image Registration (DIR) Validation. ARXIV 2025:arXiv:2501.09162v1. [PMID: 39876932 PMCID: PMC11774459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 01/31/2025]
Abstract
Purpose Deformable image registration (DIR) is an enabling technology in many diagnostic and therapeutic tasks. Despite this, DIR algorithms have limited clinical use, largely due to a lack of benchmark datasets for quality assurance during development. DIRs of intra-patient abdominal CTs are among the most challenging registration scenarios due to significant organ deformations and inconsistent image content. To support future algorithm development, here we introduce our first-of-its-kind abdominal CT DIR benchmark dataset, comprising large numbers of highly accurate landmark pairs on matching blood vessel bifurcations. Acquisition and Validation Methods Abdominal CT image pairs of 30 patients were acquired from several publicly available repositories as well as the authors' institution with IRB approval. The two CTs of each pair were originally acquired for the same patient but on different days. An image processing workflow was developed and applied to each CT image pair: 1) Abdominal organs were segmented with a deep learning model, and image intensity within organ masks was overwritten. 2) Matching image patches were manually identified between two CTs of each image pair. 3) Vessel bifurcation landmarks were labeled on one image of each image patch pair. 4) Image patches were deformably registered, and landmarks were projected onto the second image 5) Landmark pair locations were refined manually or with an automated process. This workflow resulted in 1895 total landmark pairs, or 63 per case on average. Estimates of the landmark pair accuracy using digital phantoms were 0.7mm +/- 1.2 mm. Data Format and Usage Notes The data is published in Zenodo at https://doi.org/10.5281/zenodo.14362785. Instructions for use can be found at https://github.com/deshanyang/Abdominal-DIR-QA. Potential Applications This dataset is a first-of-its-kind for abdominal DIR validation. The number, accuracy, and distribution of landmark pairs will allow for robust validation of DIR algorithms with precision beyond what is currently available.
Collapse
Affiliation(s)
- Edward R Criscuolo
- Department of Radiation Oncology, Duke University, Durham, NC, 27701, USA
| | - Yao Hao
- Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Zhendong Zhang
- Department of Radiation Oncology, Duke University, Durham, NC, 27701, USA
| | - Trevor McKeown
- Department of Radiation Oncology, Duke University, Durham, NC, 27701, USA
| | - Deshan Yang
- Department of Radiation Oncology, Duke University, Durham, NC, 27701, USA
| |
Collapse
|
2
|
Dietrich S, Dimoula M, Argyropoulos T, Ceulemans J, Goumas K, Vertzoni M, Reppas C. On the processes limiting oral drug absorption when amorphous solid dispersions are administered after a high-calorie, high-fat meal: Sporanox® pellets. Eur J Pharm Sci 2024; 199:106798. [PMID: 38740075 DOI: 10.1016/j.ejps.2024.106798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/09/2024] [Accepted: 05/10/2024] [Indexed: 05/16/2024]
Abstract
OBJECTIVES 1) Identify processes limiting the arrival of itraconazole at the intestinal epithelium when Sporanox® amorphous solid dispersion (ASD) pellets are transferred from the stomach through the upper small intestine, after a high-calorie, high-fat meal. 2) Evaluate whether itraconazole concentrations in the colloidal phase of aqueous contents of the upper small intestine are useful for the assessment of dose effects in the fed state and food effects on plasma levels. METHODS Itraconazole concentrations, apparent viscosity, and solubilization capacity were measured in aspirates from the upper gastrointestinal lumen collected during a recently performed clinical study in healthy adults. Published itraconazole concentrations in plasma, after a high-calorie high-fat meal and Sporanox® ASD pellets, and in contents of the upper small intestine of healthy adults, after administration of Sporanox® ASD pellets in the fasted state, were used to achieve the second objective. RESULTS When Sporanox® ASD pellets (up to 200 mg) are transferred from the stomach through the upper small intestine, after a high-calorie, high-fat meal, itraconazole concentrations in the colloidal phase or the micellar phase of aqueous contents of the upper small intestine are unsaturated, in most cases. During the first 3 h post-dosing after a high-calorie, high-fat meal, the impact of dose (200 mg vs. 100 mg) on itraconazole concentrations in the colloidal phase of aqueous contents of the upper small intestine seems to underestimate the impact of dose on plasma levels. When Sporanox® ASD pellets are administered after a high-calorie, high-fat meal at the 200 mg dose level, itraconazole concentrations in the colloidal phase of aqueous contents of the upper small intestine are, on average, lower than those achieved in fasted state. CONCLUSIONS When Sporanox® ASD pellets are transferred from the stomach to the upper small intestine after a high-calorie, high-fat meal, itraconazole's arrival at the intestinal epithelium seems to be limited by its arrival at the colloidal phase of aqueous contents of the upper small intestine. The impact of dose (100 mg vs. 200 mg) on plasma levels after a high-calorie, high-fat meal and during the gastrointestinal transfer of Sporanox® pellets requires consideration of pre-systemic itraconazole metabolism. At the 200 mg dose level, after taking into consideration differences in the volume of the contents of the upper small intestine between the fasted and the fed state during the gastrointestinal transfer of Sporanox® ASD pellets, itraconazole concentrations in the colloidal phase of aqueous contents of the upper small intestine suggest a mild negative food effect on average plasma levels; published clinical data are inconclusive.
Collapse
Affiliation(s)
- Shirin Dietrich
- Department of Pharmacy, National and Kapodistrian University of Athens, Zografou, Greece; Pharmaceutical and Material Sciences, Pharmaceutical Product Development and Supply, Janssen Pharmaceutica NV, Beerse, Belgium
| | - Myrto Dimoula
- Department of Pharmacy, National and Kapodistrian University of Athens, Zografou, Greece
| | | | - Jens Ceulemans
- Pharmaceutical and Material Sciences, Pharmaceutical Product Development and Supply, Janssen Pharmaceutica NV, Beerse, Belgium
| | - Konstantinos Goumas
- Department of Gastroenterology, Red Cross Hospital of Athens, Athens, Greece
| | - Maria Vertzoni
- Department of Pharmacy, National and Kapodistrian University of Athens, Zografou, Greece
| | - Christos Reppas
- Department of Pharmacy, National and Kapodistrian University of Athens, Zografou, Greece.
| |
Collapse
|
3
|
Li T, Wang J, Yang Y, Glide-Hurst CK, Wen N, Cai J. Multi-parametric MRI for radiotherapy simulation. Med Phys 2023; 50:5273-5293. [PMID: 36710376 PMCID: PMC10382603 DOI: 10.1002/mp.16256] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 09/10/2022] [Accepted: 12/06/2022] [Indexed: 01/31/2023] Open
Abstract
Magnetic resonance imaging (MRI) has become an important imaging modality in the field of radiotherapy (RT) in the past decade, especially with the development of various novel MRI and image-guidance techniques. In this review article, we will describe recent developments and discuss the applications of multi-parametric MRI (mpMRI) in RT simulation. In this review, mpMRI refers to a general and loose definition which includes various multi-contrast MRI techniques. Specifically, we will focus on the implementation, challenges, and future directions of mpMRI techniques for RT simulation.
Collapse
Affiliation(s)
- Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Jihong Wang
- Department of Radiation Physics, Division of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas, USA
| | - Yingli Yang
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong Univeristy School of Medicine, Shanghai, China
- SJTU-Ruijing-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Carri K Glide-Hurst
- Department of Radiation Oncology, University of Wisconsin, Madison, Wisconsin, USA
| | - Ning Wen
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong Univeristy School of Medicine, Shanghai, China
- SJTU-Ruijing-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
- The Global Institute of Future Technology, Shanghai Jiaotong University, Shanghai, China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
4
|
Taylor S, Lim P, Cantwell J, D’Souza D, Moinuddin S, Chang YC, Gaze MN, Gains J, Veiga C. Image guidance and interfractional anatomical variation in paediatric abdominal radiotherapy. Br J Radiol 2023; 96:20230058. [PMID: 37102707 PMCID: PMC10230397 DOI: 10.1259/bjr.20230058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/22/2023] [Accepted: 03/23/2023] [Indexed: 04/28/2023] Open
Abstract
OBJECTIVES To identify variables predicting interfractional anatomical variations measured with cone-beam CT (CBCT) throughout abdominal paediatric radiotherapy, and to assess the potential of surface-guided radiotherapy (SGRT) to monitor these changes. METHODS Metrics of variation in gastrointestinal (GI) gas volume and separation of the body contour and abdominal wall were calculated from 21 planning CTs and 77 weekly CBCTs for 21 abdominal neuroblastoma patients (median 4 years, range: 2 - 19 years). Age, sex, feeding tubes, and general anaesthesia (GA) were explored as predictive variables for anatomical variation. Furthermore, GI gas variation was correlated with changes in body and abdominal wall separation, as well as simulated SGRT metrics of translational and rotational corrections between CT/CBCT. RESULTS GI gas volumes varied 74 ± 54 ml across all scans, while body and abdominal wall separation varied 2.0 ± 0.7 mm and 4.1 ± 1.5 mm from planning, respectively. Patients < 3.5 years (p = 0.04) and treated under GA (p < 0.01) experienced greater GI gas variation; GA was the strongest predictor in multivariate analysis (p < 0.01). Absence of feeding tubes was linked to greater body contour variation (p = 0.03). GI gas variation correlated with body (R = 0.53) and abdominal wall (R = 0.63) changes. The strongest correlations with SGRT metrics were found for anterior-posterior translation (R = 0.65) and rotation of the left-right axis (R = -0.36). CONCLUSIONS Young age, GA, and absence of feeding tubes were linked to stronger interfractional anatomical variation and are likely indicative of patients benefiting from adaptive/robust planning pathways. Our data suggest a role for SGRT to inform the need for CBCT at each treatment fraction in this patient group. ADVANCES IN KNOWLEDGE This is the first study to suggest the potential role of SGRT for the management of internal interfractional anatomical variation in paediatric abdominal radiotherapy.
Collapse
Affiliation(s)
- Sabrina Taylor
- University College London, Centre for Medical Image Computing, London, United Kingdom
| | - Pei Lim
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Jessica Cantwell
- Radiotherapy, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Derek D’Souza
- Radiotherapy, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Syed Moinuddin
- Radiotherapy, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Yen-Ching Chang
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Mark N Gaze
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Jennifer Gains
- Department of Oncology, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Catarina Veiga
- University College London, Centre for Medical Image Computing, London, United Kingdom
| |
Collapse
|
5
|
Zhang Y, Balter J, Dow J, Cao Y, Lawrence TS, Kashani R. Development of an abdominal dose accumulation tool and assessments of accumulated dose in gastrointestinal organs. Phys Med Biol 2023; 68:10.1088/1361-6560/acbc61. [PMID: 36791470 PMCID: PMC10131348 DOI: 10.1088/1361-6560/acbc61] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 02/15/2023] [Indexed: 02/17/2023]
Abstract
Objective.Online adaptive radiotherapy has demonstrated improved dose conformality in response to inter-fraction geometric variations in the abdomen. The dosimetric impact of intra-fractional variations in anatomic configuration resulting from breathing, gastric contraction and slow configuration motion, however, have been largely ignored, leading to differences between delivered and planned. To investigate the impact of intra-fractional abdominal motions on delivered dose, anatomical deformations due to these three motion modes were extracted from dynamic MRI data using a previously developed hierarchical motion modeling methodology.Approach. Motion magnitudes were extracted from deformation fields between a reference state and all other motion states of the patient. Delivered dose estimates to various gastrointestinal organs (stomach, duodenum, small bowel and colon) were calculated on each motion state of the patient and accumulated to estimate the delivered dose to each organ for the entire treatment fraction.Main results. Across a sample of 10 patients, maximal motions of 33.6, 33.4, 47.6 and 49.2 mm were observed over 20 min for the stomach, duodenum, small bowel and colon respectively. Dose accumulation results showed that motions could lead to average increases of 2.0, 2.1, 1.1, 0.7 Gy to the maximum dose to 0.5cc (D0.5cc) and 3.0, 2.5, 1.3, 0.9 Gy to the maximum dose to 0.1cc (D0.1cc) for these organs at risk. From the 40 dose accumulations performed (10 for each organ at risk), 27 showed increases of modeled delivered dose compared to planned doses, 4 of which exceeded planned dose constraints.Significance. The use of intra-fraction motion measurements to accumulate delivered doses is feasible, and supports retrospective estimation of dose delivery to improve estimates of delivered doses, and further guide strategies for both plan adaptation as well as advances in intra-fraction motion management.
Collapse
Affiliation(s)
- Yuhang Zhang
- Department of Radiation Oncology, University of Michigan, United States of America
- Department of Biomedical Engineering, University of Michigan, United States of America
| | - James Balter
- Department of Radiation Oncology, University of Michigan, United States of America
- Department of Biomedical Engineering, University of Michigan, United States of America
| | - Janell Dow
- Department of Radiation Oncology, University of Michigan, United States of America
| | - Yue Cao
- Department of Radiation Oncology, University of Michigan, United States of America
- Department of Biomedical Engineering, University of Michigan, United States of America
- Department of Radiology, University of Michigan, United States of America
| | - Theodore S Lawrence
- Department of Radiation Oncology, University of Michigan, United States of America
| | - Rojano Kashani
- Department of Radiation Oncology, University Hospitals Seidman Cancer Center, United States of America
| |
Collapse
|
6
|
Ng J, Gregucci F, Pennell RT, Nagar H, Golden EB, Knisely JPS, Sanfilippo NJ, Formenti SC. MRI-LINAC: A transformative technology in radiation oncology. Front Oncol 2023; 13:1117874. [PMID: 36776309 PMCID: PMC9911688 DOI: 10.3389/fonc.2023.1117874] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 01/16/2023] [Indexed: 01/28/2023] Open
Abstract
Advances in radiotherapy technologies have enabled more precise target guidance, improved treatment verification, and greater control and versatility in radiation delivery. Amongst the recent novel technologies, Magnetic Resonance Imaging (MRI) guided radiotherapy (MRgRT) may hold the greatest potential to improve the therapeutic gains of image-guided delivery of radiation dose. The ability of the MRI linear accelerator (LINAC) to image tumors and organs with on-table MRI, to manage organ motion and dose delivery in real-time, and to adapt the radiotherapy plan on the day of treatment while the patient is on the table are major advances relative to current conventional radiation treatments. These advanced techniques demand efficient coordination and communication between members of the treatment team. MRgRT could fundamentally transform the radiotherapy delivery process within radiation oncology centers through the reorganization of the patient and treatment team workflow process. However, the MRgRT technology currently is limited by accessibility due to the cost of capital investment and the time and personnel allocation needed for each fractional treatment and the unclear clinical benefit compared to conventional radiotherapy platforms. As the technology evolves and becomes more widely available, we present the case that MRgRT has the potential to become a widely utilized treatment platform and transform the radiation oncology treatment process just as earlier disruptive radiation therapy technologies have done.
Collapse
Affiliation(s)
- John Ng
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States,*Correspondence: John Ng,
| | - Fabiana Gregucci
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States,Department of Radiation Oncology, Miulli General Regional Hospital, Acquaviva delle Fonti, Bari, Italy
| | - Ryan T. Pennell
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | - Himanshu Nagar
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | - Encouse B. Golden
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | | | | | - Silvia C. Formenti
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| |
Collapse
|
7
|
Castelluccia A, Mincarone P, Tumolo MR, Sabina S, Colella R, Bodini A, Tramacere F, Portaluri M, Leo CG. Economic Evaluations of Magnetic Resonance Image-Guided Radiotherapy (MRIgRT): A Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph191710800. [PMID: 36078513 PMCID: PMC9517760 DOI: 10.3390/ijerph191710800] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 08/17/2022] [Accepted: 08/20/2022] [Indexed: 05/06/2023]
Abstract
OBJECTIVES This review systematically summarizes the evidence on the economic impact of magnetic resonance image-guided RT (MRIgRT). METHODS We systematically searched INAHTA, MEDLINE, and Scopus up to March 2022 to retrieve health economic studies. Relevant data were extracted on study type, model inputs, modeling methods and economic results. RESULTS Five studies were included. Two studies performed a full economic assessment to compare the cost-effectiveness of MRIgRT with other forms of image-guided radiation therapy. One study performed a cost minimization analysis and two studies performed an activity-based costing, all comparing MRIgRT with X-ray computed tomography image-guided radiation therapy (CTIgRT). Prostate cancer was the target condition in four studies and hepatocellular carcinoma in one. Considering the studies with a full economic assessment, MR-guided stereotactic body radiation therapy was found to be cost effective with respect to CTIgRT or conventional or moderate hypofractionated RT, even with a low reduction in toxicity. Conversely, a greater reduction in toxicity is required to compete with extreme hypofractionated RT without MR guidance. CONCLUSIONS This review highlights the great potential of MRIgRT but also the need for further evidence, especially for late toxicity, whose reduction is expected to be the real added value of this technology.
Collapse
Affiliation(s)
- Alessandra Castelluccia
- Radiation Oncology, Department of Radiotherapy, Hospital “A. Perrino”, ASL Brindisi, 72100 Brindisi, Italy
| | - Pierpaolo Mincarone
- Institute for Research on Population and Social Policies, National Research Council, 72100 Brindisi, Italy
- MOVE-Mentis s.r.l., 47522 Cesena, Italy
- Correspondence: ; Tel.: +39-3289168745
| | - Maria Rosaria Tumolo
- Department of Biological and Environmental Sciences and Technology, University of Salento, 73100 Lecce, Italy
| | - Saverio Sabina
- MOVE-Mentis s.r.l., 47522 Cesena, Italy
- Institute of Clinical Physiology, National Research Council, 73100 Lecce, Italy
| | - Riccardo Colella
- Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy
| | - Antonella Bodini
- Institute for Applied Mathematics and Information Technologies “E. Magenes”, National Research Council, 20133 Milan, Italy
| | - Francesco Tramacere
- Radiation Oncology, Department of Radiotherapy, Hospital “A. Perrino”, ASL Brindisi, 72100 Brindisi, Italy
| | - Maurizio Portaluri
- Radiation Oncology, Department of Radiotherapy, Hospital “A. Perrino”, ASL Brindisi, 72100 Brindisi, Italy
| | - Carlo Giacomo Leo
- MOVE-Mentis s.r.l., 47522 Cesena, Italy
- Institute of Clinical Physiology, National Research Council, 73100 Lecce, Italy
| |
Collapse
|
8
|
Hall WA, Paulson E, Li XA, Erickson B, Schultz C, Tree A, Awan M, Low DA, McDonald BA, Salzillo T, Glide-Hurst CK, Kishan AU, Fuller CD. Magnetic resonance linear accelerator technology and adaptive radiation therapy: An overview for clinicians. CA Cancer J Clin 2022; 72:34-56. [PMID: 34792808 PMCID: PMC8985054 DOI: 10.3322/caac.21707] [Citation(s) in RCA: 51] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 09/01/2021] [Accepted: 09/22/2021] [Indexed: 12/25/2022] Open
Abstract
Radiation therapy (RT) continues to play an important role in the treatment of cancer. Adaptive RT (ART) is a novel method through which RT treatments are evolving. With the ART approach, computed tomography or magnetic resonance (MR) images are obtained as part of the treatment delivery process. This enables the adaptation of the irradiated volume to account for changes in organ and/or tumor position, movement, size, or shape that may occur over the course of treatment. The advantages and challenges of ART maybe somewhat abstract to oncologists and clinicians outside of the specialty of radiation oncology. ART is positioned to affect many different types of cancer. There is a wide spectrum of hypothesized benefits, from small toxicity improvements to meaningful gains in overall survival. The use and application of this novel technology should be understood by the oncologic community at large, such that it can be appropriately contextualized within the landscape of cancer therapies. Likewise, the need to test these advances is pressing. MR-guided ART (MRgART) is an emerging, extended modality of ART that expands upon and further advances the capabilities of ART. MRgART presents unique opportunities to iteratively improve adaptive image guidance. However, although the MRgART adaptive process advances ART to previously unattained levels, it can be more expensive, time-consuming, and complex. In this review, the authors present an overview for clinicians describing the process of ART and specifically MRgART.
Collapse
MESH Headings
- History, 20th Century
- History, 21st Century
- Humans
- Magnetic Resonance Imaging, Interventional/history
- Magnetic Resonance Imaging, Interventional/instrumentation
- Magnetic Resonance Imaging, Interventional/methods
- Magnetic Resonance Imaging, Interventional/trends
- Neoplasms/diagnostic imaging
- Neoplasms/radiotherapy
- Particle Accelerators
- Radiation Oncology/history
- Radiation Oncology/instrumentation
- Radiation Oncology/methods
- Radiation Oncology/trends
- Radiotherapy Planning, Computer-Assisted/history
- Radiotherapy Planning, Computer-Assisted/instrumentation
- Radiotherapy Planning, Computer-Assisted/methods
- Radiotherapy Planning, Computer-Assisted/trends
Collapse
Affiliation(s)
- William A. Hall
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Eric Paulson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - X. Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Beth Erickson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Christopher Schultz
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Alison Tree
- The Royal Marsden National Health Service Foundation Trust and the Institute of Cancer Research, London, United Kingdom
| | - Musaddiq Awan
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Daniel A. Low
- Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, California
| | - Brigid A. McDonald
- Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas
| | - Travis Salzillo
- Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas
| | - Carri K. Glide-Hurst
- Department of Radiation Oncology, University of Wisconsin-Madison, Madison, Wisconsin
| | - Amar U. Kishan
- Department of Radiation Oncology, University of California-Los Angeles, Los Angeles, California
| | - Clifton D. Fuller
- Department of Radiation Oncology, The University of Texas, MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
9
|
Liu L, Johansson A, Cao Y, Kashani R, Lawrence TS, Balter JM. Modeling intra-fractional abdominal configuration changes using breathing motion-corrected radial MRI. Phys Med Biol 2021; 66. [PMID: 33725676 DOI: 10.1088/1361-6560/abef42] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Accepted: 03/16/2021] [Indexed: 12/11/2022]
Abstract
Abdominal organ motions introduce geometric uncertainties to gastrointestinal radiotherapy. This study investigated slow drifting motion induced by changes of internal anatomic organ arrangements using a 3D radial MRI sequence with a scan length of 20 min. Breathing motion and cyclic GI motion were first removed through multi-temporal resolution image reconstruction. Slow drifting motion analysis was performed using an image time series consisting of 72 image volumes with a temporal sampling rate of 17 s. B-spline deformable registration was performed to align image volumes of the time series to a reference volume. The resulting deformation fields were used for motion velocity evaluation and patient-specific motion model construction through principal component analysis (PCA). Geometric uncertainties introduced by slow drifting motion were assessed by Hausdorff distances between unions of organs at risk (OARs) at different motion states and reference OAR contours as well as probabilistic distributions of OARs predicted using the PCA model. Thirteen examinations from 11 patients were included in this study. The averaged motion velocities ranged from 0.8 to 1.9 mm min-1, 0.7 to 1.6 mm min-1, 0.6 to 2.0 mm min-1and 0.7 to 1.4 mm min-1for the small bowel, colon, duodenum and stomach respectively; the averaged Hausdorff distances were 5.6 mm, 5.3 mm, 5.1 mm and 4.6 mm. On average, a margin larger than 4.5 mm was needed to cover a space with OAR occupancy probability higher than 55%. Temporal variations of geometric uncertainties were evaluated by comparing across four 5 min sub-scans extracted from the full scan. Standard deviations of Hausdorff distances across sub-scans were less than 1 mm for most examinations, indicating stability of relative margin estimates from separate time windows. These results suggested slow drifting motion of GI organs is significant and geometric uncertainties introduced by such motion should be accounted for during radiotherapy planning and delivery.
Collapse
Affiliation(s)
- Lianli Liu
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109, United States of America.,Department of Radiation Oncology, Stanford University, Palo Alto, CA 94304, United States of America
| | - Adam Johansson
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109, United States of America.,Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, SE 75185, Sweden.,Department of Surgical Sciences, Uppsala University, Uppsala, SE 75185, Sweden
| | - Yue Cao
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109, United States of America.,Department of Radiology, University of Michigan, Ann Arbor, MI 48109, United States of America.,Department of biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States of America
| | - Rojano Kashani
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109, United States of America
| | - Theodore S Lawrence
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109, United States of America
| | - James M Balter
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109, United States of America
| |
Collapse
|
10
|
Zhang Y, Kashani R, Cao Y, Lawrence TS, Johansson A, Balter JM. A hierarchical model of abdominal configuration changes extracted from golden angle radial magnetic resonance imaging. Phys Med Biol 2021; 66:045018. [PMID: 33361579 PMCID: PMC7993537 DOI: 10.1088/1361-6560/abd66e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Abdominal organs are subject to a variety of physiological forces that superimpose their effects to influence local motion and configuration. These forces not only include breathing, but can also arise from cyclic antral contractions and a range of slow configuration changes. To elucidate each individual motion pattern as well as their combined effects, a hierarchical motion model was built for characterization of these 3 motion modes (characterized as deformation maps between states) using golden angle radial MR signals. Breathing motions are characterized first. Antral contraction states are then reconstructed after breathing motion-induced deformation are corrected; slow configuration change states are further extracted from breathing motion-corrected image reconstructions. The hierarchical model is established based on these multimodal states, which can be either individually shown or combined to demonstrate any arbitrary composited motion patterns. The model was evaluated using 20 MR scans acquired from 9 subjects. Poor reproducibility of breathing motions both within as well as between scan sessions was observed, with an average intra-subject difference of 1.6 cycles min-1 for average breathing frequencies of 12.0 cycles min-1. Antral contraction frequency distributions were more stable than breathing, but also presented poor reproducibility between scans with an average difference of 0.3 cycles min-1 for average frequencies of 3.2 cycles min-1. The magnitudes of motions beyond breathing were found to be significant, with 14.4 and 33.8 mm maximal motions measured from antral contraction and slow configuration changes, respectively. Hierarchical motion models have potential in multiple applications in radiotherapy, including improving the accuracy of dose delivery estimation, providing guidance for margin creation, and supporting advanced decisions and strategies for immobilization, treatment monitoring and gating.
Collapse
Affiliation(s)
- Yuhang Zhang
- Department of Radiation Oncology, University of Michigan, United States of America
- Department of Biomedical Engineering, University of Michigan, United States of America
| | - Rojano Kashani
- Department of Radiation Oncology, University of Michigan, United States of America
| | - Yue Cao
- Department of Radiation Oncology, University of Michigan, United States of America
- Department of Biomedical Engineering, University of Michigan, United States of America
- Department of Radiology, University of Michigan, United States of America
| | - Theodore S Lawrence
- Department of Radiation Oncology, University of Michigan, United States of America
| | - Adam Johansson
- Department of Surgical Sciences, Uppsala University, Sweden
| | - James M Balter
- Department of Radiation Oncology, University of Michigan, United States of America
- Department of Biomedical Engineering, University of Michigan, United States of America
| |
Collapse
|
11
|
Kunogi H, Yamaguchi N, Terao Y, Sasai K. Dosimetric predictors of nephrotoxicity in patients receiving extended-field radiation therapy for gynecologic cancer. Radiat Oncol 2021; 16:25. [PMID: 33541379 PMCID: PMC7863447 DOI: 10.1186/s13014-021-01755-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 01/28/2021] [Indexed: 11/10/2022] Open
Abstract
Purpose We sought dosimetric predictors of a decreasing estimated glomerular filtration rate (eGFR) in gynecological oncology patients receiving extended-field radiation therapy (EFRT). Materials and methods Between July 2012 and April 2020, 98 consecutive cervical or endometrial cancer patients underwent EFRT or whole-pelvis radiation therapy (WPRT) with concurrent cisplatin chemotherapy in our institution. To explore the effect of concurrent cisplatin chemotherapy on renal function, the renal function of the WPRT patients was examined. Of the 98 patients, 34 cervical or endometrial cancer patients underwent EFRT including extended-field intensity-modulated radiation therapy (EF-IMRT) and 64 cervical cancer patients underwent WPRT with cisplatin. Of the 34 EFRT patients, 32 underwent concurrent cisplatin chemotherapy. Excluding patients exhibiting recurrences within 6 months, 31 EFRT patients were analyzed in terms of the dose-volume kidney histograms (the percentages of kidney volumes receiving 12, 16, 20, and 24 Gy) and the post- to pre-treatment eGFR ratios. We calculated Pearson correlation coefficients between the renal dose volume and the percentage eGFR reductions of the 31 EFRT patients, and those treated via EF-IMRT. Renal dose constraint significance was evaluated using the Mann–Whitney U test. Results The eGFR value after WPRT with cisplatin remained largely unchanged for 12 months, unlike that after EFRT. In EFRT patients, a strong correlation was evident between the KV20Gy dose and the post- to pre-treatment eGFR ratio (correlation coefficients − 0.80 for all patients and − 0.74 for EF-IMRT patients). In EF-IMRT patients, the kidney volume receiving 20 Gy tended to correlate negatively with the eGFR reduction. The Mann–Whitney U test showed that patients with KV20Gy values < 10% retained significantly better renal function than did patients with KV20Gy values > 10% (P = 0.002). Conclusions Imposition of a severe kidney dose constraint during EF-IMRT may reduce nephrotic toxicity. Future prospective investigations of kidney-sparing EF-IMRT are required.
Collapse
Affiliation(s)
- Hiroaki Kunogi
- Department of Radiation Oncology, Juntendo University, 2-1-1, Hongo, Bunkyo-ku, Tokyo, 113-8421, Japan.
| | - Nanae Yamaguchi
- Department of Radiation Oncology, Juntendo University, 2-1-1, Hongo, Bunkyo-ku, Tokyo, 113-8421, Japan
| | - Yasuhisa Terao
- Department of Gynecology, Juntendo University, Tokyo, Japan
| | - Keisuke Sasai
- Department of Radiation Oncology, Juntendo University, 2-1-1, Hongo, Bunkyo-ku, Tokyo, 113-8421, Japan
| |
Collapse
|
12
|
Hashimoto M, Taguchi Y. Circular pyramidal kirigami microscanner with millimeter-range low-power lens drive. OPTICS EXPRESS 2020; 28:17457-17467. [PMID: 32679953 DOI: 10.1364/oe.394908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 05/16/2020] [Indexed: 06/11/2023]
Abstract
This paper proposes an electrothermally-actuated circular pyramidal kirigami microscanner with a millimeter-range low-power lens drive for endoscopic biomedical applications. A variation of Japanese origami art, kirigami involves creation of out-of-plane structures by paper cutting and folding. The proposed microscanner is composed of freestanding kirigami film on which the spiral-curved thermal bimorphs are strategically placed. The kirigami microscanner is electrothermally transformed into an out-of-plane circular multistep pyramid by Joule heating. The circular pyramidal kirigami microscanner on a small footprint of 4.5 mm × 4.5 mm was fabricated by microelectromechanical system processes. A large four-step pyramidal actuation was successfully demonstrated, and a large 1.1-mm lens travel range at only 128 mW was achieved.
Collapse
|
13
|
Repeatability and Reproducibility of Pancreas Volume Measurements Using MRI. Sci Rep 2020; 10:4767. [PMID: 32179809 PMCID: PMC7076034 DOI: 10.1038/s41598-020-61759-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Accepted: 03/02/2020] [Indexed: 11/08/2022] Open
Abstract
Reduced pancreas volume, as measured by non-contrast magnetic resonance imaging (MRI), is observed in individuals with newly-diagnosed type 1 diabetes (T1D) and declines over the first year after diagnosis. In this study, we determined the repeatability and inter-reader reproducibility of pancreas volume measurements by MRI. Test-retest scans in individuals with or without T1D (n = 16) had an intraclass correlation coefficient (ICC) of 0.985 (95% CI 0.961 to 0.995) for pancreas volume. Independent pancreas outlines by two board-certified radiologists (n = 30) yielded an ICC of 0.945 (95% CI 0.889 to 0.973). The mean Dice coefficient, a measurement of the degree of overlap between pancreas regions of interest between the two readers, was 0.77. Prandial state did not influence pancreatic measurements, as stomach volume did not correlate with pancreas volume. These data demonstrate that MRI measurements of pancreas volume between two readers are repeatable and reproducible with ICCs that correspond to excellent clinical significance (ICC > 0.9), are not related to changes in stomach volume, and could be a useful tool for clinical investigation of diabetes and other pancreas pathologies.
Collapse
|