1
|
Jung JY, Yoo KD, Kang E, Kang HG, Kim SH, Kim H, Kim HJ, Park TJ, Suh SH, Jeong JC, Choi JY, Hwang YH, Choi M, Kim YL, Oh KH. Executive summary of the Korean Society of Nephrology 2021 clinical practice guideline for optimal hemodialysis treatment. Korean J Intern Med 2022; 37:701-718. [PMID: 35811360 PMCID: PMC9271711 DOI: 10.3904/kjim.2021.543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 01/12/2022] [Indexed: 12/05/2022] Open
Abstract
The Korean Society of Nephrology (KSN) has published a clinical practice guideline (CPG) document for maintenance hemodialysis (HD). The document, 2021 Clinical Practice Guideline on Optimal HD Treatment, is based on an extensive evidence-oriented review of the benefits of preparation, initiation, and maintenance therapy for HD, with the participation of representative experts from the KSN under the methodologists' support for guideline development. It was intended to help clinicians participating in HD treatment make safer and more effective clinical decisions by providing user-friendly guidelines. We hope that this CPG will be meaningful as a recommendation in practice, but not on a regulatory rule basis, as different approaches and treatments may be used by health care providers depending on the individual patient's condition. This CPG consists of eight sections and 15 key questions. Each begins with statements that are graded by the strength of recommendations and quality of the evidence. Each statement is followed by a summary of the evidence supporting the recommendations. There are also a link to full-text documents and lists of the most important reports so that the readers can read further (most of this is available online).
Collapse
Affiliation(s)
- Ji Yong Jung
- Division of Nephrology, Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon,
Korea
| | - Kyung Don Yoo
- Division of Nephrology, Department of Internal Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan,
Korea
| | - Eunjeong Kang
- Division of Nephrology, Department of Internal Medicine, Ewha Womans University Seoul Hospital, Ewha Womans University School of Medicine, Seoul,
Korea
| | - Hee Gyung Kang
- Division of Pediatric Nephrology, Department of Pediatrics, Seoul National University Children’s Hospital, Seoul,
Korea
| | - Su Hyun Kim
- Division of Nephrology, Department of Internal Medicine, Chung-Ang University Hospital, Seoul,
Korea
| | - Hyoungnae Kim
- Division of Nephrology, Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Seoul,
Korea
| | - Hyo Jin Kim
- Division of Nephrology, Department of Internal Medicine, Pusan National University Hospital, Busan,
Korea
| | | | - Sang Heon Suh
- Division of Nephrology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju,
Korea
| | - Jong Cheol Jeong
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam,
Korea
| | - Ji-Young Choi
- Division of Nephrology, Department of Internal Medicine, Kyungpook National University Chilgok Hospital, Daegu,
Korea
| | | | - Miyoung Choi
- Division for Healthcare Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency, Seoul,
Korea
| | - Yae Lim Kim
- Department of Biostatistics, Korea University College of Medicine, Seoul,
Korea
| | - Kook-Hwan Oh
- Division of Nephrology, Department of Internal Medicine, Seoul National University Hospital, Seoul,
Korea
| | | |
Collapse
|
2
|
Jung JY, Yoo KD, Kang E, Kang HG, Kim SH, Kim H, Kim HJ, Park TJ, Suh SH, Jeong JC, Choi JY, Hwang YH, Choi M, Kim YL, Oh KH. Executive Summary of the Korean Society of Nephrology 2021 Clinical Practice Guideline for Optimal Hemodialysis Treatment. Kidney Res Clin Pract 2021; 40:578-595. [PMID: 34922430 PMCID: PMC8685366 DOI: 10.23876/j.krcp.21.700] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 10/18/2021] [Indexed: 12/17/2022] Open
Abstract
The Korean Society of Nephrology (KSN) has published a clinical practice guideline (CPG) document for maintenance hemodialysis (HD). The document, 2021 Clinical Practice Guideline on Optimal HD Treatment, is based on an extensive evidence-oriented review of the benefits of preparation, initiation, and maintenance therapy for HD, with the participation of representative experts from the KSN under the methodologists’ support for guideline development. It was intended to help clinicians participating in HD treatment make safer and more effective clinical decisions by providing user-friendly guidelines. We hope that this CPG will be meaningful as a recommendation in practice, but not on a regulatory rule basis, as different approaches and treatments may be used by health care providers depending on the individual patient’s condition. This CPG consists of eight sections and 15 key questions. Each begins with statements that are graded by the strength of recommendations and quality of the evidence. Each statement is followed by a summary of the evidence supporting the recommendations. There is also a link to full-text documents and lists of the most important reports so that the readers can read further (most of this is available online).
Collapse
Affiliation(s)
- Ji Yong Jung
- Division of Nephrology, Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Kyung Don Yoo
- Division of Nephrology, Department of Internal Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea
| | - Eunjeong Kang
- Division of Nephrology, Department of Internal Medicine, Ewha Womans University Seoul Hospital, Ewha Womans College of Medicine, Seoul, Republic of Korea
| | - Hee Gyung Kang
- Division of Pediatric Nephrology, Department of Pediatrics, Seoul National University Children's Hospital, Seoul, Republic of Korea
| | - Su Hyun Kim
- Division of Nephrology, Department of Internal Medicine, Chung-Ang University Hospital, Seoul, Republic of Korea
| | - Hyoungnae Kim
- Division of Nephrology, Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Seoul, Republic of Korea
| | - Hyo Jin Kim
- Division of Nephrology, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
| | - Tae-Jin Park
- Asan Jin Internal Medicine Clinic, Seoul, Republic of Korea
| | - Sang Heon Suh
- Division of Nephrology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Jong Cheol Jeong
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Ji-Young Choi
- Division of Nephrology, Department of Internal Medicine, Kyungpook National University Chilgok Hospital, Daegu, Republic of Korea
| | | | - Miyoung Choi
- Division for Healthcare Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency, Seoul, Republic of Korea
| | - Yae Lim Kim
- Department of Biostatistics, Korea University College of Medicine, Seoul, Republic of Korea
| | - Kook-Hwan Oh
- Division of Nephrology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | | |
Collapse
|
3
|
Jung JY, Yoo KD, Kang E, Kang HG, Kim SH, Kim H, Kim HJ, Park TJ, Suh SH, Jeong JC, Choi JY, Hwang YH, Choi M, Kim YL, Oh KH. Korean Society of Nephrology 2021 Clinical Practice Guideline for Optimal Hemodialysis Treatment. Kidney Res Clin Pract 2021; 40:S1-S37. [PMID: 34923803 PMCID: PMC8694695 DOI: 10.23876/j.krcp.21.600] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 10/19/2021] [Indexed: 01/06/2023] Open
Affiliation(s)
- Ji Yong Jung
- Division of Nephrology, Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - Kyung Don Yoo
- Division of Nephrology, Department of Internal Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea
| | - Eunjeong Kang
- Division of Nephrology, Department of Internal Medicine, Ewha Womans University Seoul Hospital, Ewha Womans College of Medicine, Seoul, Republic of Korea
| | - Hee Gyung Kang
- Division of Pediatric Nephrology, Department of Pediatrics, Seoul National University Children’s Hospital, Seoul, Republic of Korea
| | - Su Hyun Kim
- Division of Nephrology, Department of Internal Medicine, Chung-Ang University Hospital, Seoul, Republic of Korea
| | - Hyoungnae Kim
- Division of Nephrology, Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Seoul, Republic of Korea
| | - Hyo Jin Kim
- Division of Nephrology, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
| | - Tae-Jin Park
- Asan Jin Internal Medicine Clinic, Seoul, Republic of Korea
| | - Sang Heon Suh
- Division of Nephrology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Jong Cheol Jeong
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
| | - Ji-Young Choi
- Division of Nephrology, Department of Internal Medicine, Kyungpook National University Chilgok Hospital, Daegu, Republic of Korea
| | | | - Miyoung Choi
- Division for Healthcare Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency, Seoul, Republic of Korea
| | - Yae Lim Kim
- Department of Biostatistics, Korea University College of Medicine, Seoul, Republic of Korea
| | - Kook-Hwan Oh
- Division of Nephrology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | - for the Korean Society of Nephrology Clinical Practice Guideline Work Group
- Division of Nephrology, Department of Internal Medicine, Gachon University Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Ewha Womans University Seoul Hospital, Ewha Womans College of Medicine, Seoul, Republic of Korea
- Division of Pediatric Nephrology, Department of Pediatrics, Seoul National University Children’s Hospital, Seoul, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Chung-Ang University Hospital, Seoul, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Soonchunhyang University Seoul Hospital, Seoul, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
- Asan Jin Internal Medicine Clinic, Seoul, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Kyungpook National University Chilgok Hospital, Daegu, Republic of Korea
- Truewords Dialysis Clinic, Incheon, Republic of Korea
- Division for Healthcare Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency, Seoul, Republic of Korea
- Department of Biostatistics, Korea University College of Medicine, Seoul, Republic of Korea
- Division of Nephrology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| |
Collapse
|
4
|
Saad HKM, Taib WRW, Ismail I, Johan MF, Al-Wajeeh AS, Al-Jamal HAN. Reduced hepcidin expression enhances iron overload in patients with HbE/β-thalassemia: Α comparative cross-sectional study. Exp Ther Med 2021; 22:1402. [PMID: 34675995 PMCID: PMC8524734 DOI: 10.3892/etm.2021.10838] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 08/26/2021] [Indexed: 12/15/2022] Open
Abstract
Iron homeostasis is regulated by hepcidin (HEPC) that controls the dietary iron absorption and iron recycling. HEPC deficiency contributes to iron overload in β-thalassemia patients. The present study aimed to investigate the correlation between HEPC concentration and serum iron status among hemoglobin E (HbE)/β-thalassemia patients and their parents (HbE trait and β-thalassemia trait) compared with healthy controls. This study is a comparative cross-sectional study in which iron profile and HEPC level were examined in 65 HbE/β-thalassemia patients (pretransfusion) and 65 parents at the Hospital Sultanah Nur Zahirah and in 130 students as healthy controls from Univesiti Sultan Zainal Abidin, Terengganu, Malaysia. Furthermore, six samples from each group (HbE/β-thalassemia patients, parents and healthy controls) were randomly selected for gene expression analysis of HEPC and ferroportin1 (FPN1) using reverse transcription quantitative PCR. The results demonstrated that serum HEPC level were significantly decreased in HbE/β-thalassemia patients and their parents (P<0.001) compared with healthy controls. In addition, the gene expression analysis showed a dramatically downregulated HEPC in HbE/β-thalassemia patients and their parents (P=0.001) compared with healthy controls. However, there was a marked upregulation of FPN1 in HbE/β-thalassemia patients and their parents (P=0.001) compared with healthy controls. Iron profiling results revealed a significantly increased serum ferritin in HbE/β-thalassemia patients and their parents compared with healthy controls (P<0.001). In summary, the present study demonstrated that HEPC expression level and serum level were significantly decreased in HbE/β-thalassemia patients and their parents, which was combined with a marked increased FPN1 expression level and serum ferritin level compared with healthy volunteers. These findings supported the hypothesis that downregulated HEPC could lose its function as a negative regulator of FPN1, resulting in iron overload in HbE/β-thalassemia patients. Subsequently, assessing HEPC and FPN1 gene expression may be a useful tool to determine the risk of iron toxicity in patients with HbE/β-thalassemia and their parents, and could therefore be considered as a therapeutic target in the management of iron burden in these patients.
Collapse
Affiliation(s)
- Hanan Kamel M Saad
- School of Biomedicine, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Gong Badak Campus, 21300 Terengganu, Kelantan, Malaysia
| | - Wan Rohani Wan Taib
- School of Biomedicine, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Gong Badak Campus, 21300 Terengganu, Kelantan, Malaysia
| | - Imilia Ismail
- School of Biomedicine, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Gong Badak Campus, 21300 Terengganu, Kelantan, Malaysia
| | - Muhammad Farid Johan
- Department of Haematology, School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, 16150 Kota Bharu, Kelantan, Malaysia
| | | | - Hamid Ali Nagi Al-Jamal
- School of Biomedicine, Faculty of Health Sciences, Universiti Sultan Zainal Abidin, Gong Badak Campus, 21300 Terengganu, Kelantan, Malaysia
| |
Collapse
|
5
|
The Influence of Inflammation on Anemia in CKD Patients. Int J Mol Sci 2020; 21:ijms21030725. [PMID: 31979104 PMCID: PMC7036805 DOI: 10.3390/ijms21030725] [Citation(s) in RCA: 78] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 01/15/2020] [Accepted: 01/19/2020] [Indexed: 02/06/2023] Open
Abstract
Anemia is frequently observed in the course of chronic kidney disease (CKD) and it is associated with diminishing the quality of a patient’s life. It also enhances morbidity and mortality and hastens the CKD progression rate. Patients with CKD frequently suffer from a chronic inflammatory state which is related to a vast range of underlying factors. The results of studies have demonstrated that persistent inflammation may contribute to the variability in Hb levels and hyporesponsiveness to erythropoietin stimulating agents (ESA), which are frequently observed in CKD patients. The understanding of the impact of inflammatory cytokines on erythropoietin production and hepcidin synthesis will enable one to unravel the net of interactions of multiple factors involved in the pathogenesis of the anemia of chronic disease. It seems that anti-cytokine and anti-oxidative treatment strategies may be the future of pharmacological interventions aiming at the treatment of inflammation-associated hyporesponsiveness to ESA. The discovery of new therapeutic approaches towards the treatment of anemia in CKD patients has become highly awaited. The treatment of anemia with erythropoietin (EPO) was associated with great benefits for some patients but not all.
Collapse
|
6
|
Reporting of "dialysis adequacy" as an outcome in randomised trials conducted in adults on haemodialysis. PLoS One 2019; 14:e0207045. [PMID: 30721242 PMCID: PMC6363141 DOI: 10.1371/journal.pone.0207045] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Accepted: 12/04/2018] [Indexed: 12/16/2022] Open
Abstract
Background Clinical trials are most informative for evidence-based decision-making when they consistently measure and report outcomes of relevance to stakeholders, especially patients, clinicians, and policy makers. However, sometimes terminology used is interpreted differently by different stakeholders, which might lead to confusion during shared decision making. The construct dialysis adequacy is frequently used, suggesting it is an important outcome both for health care professionals as for patients. Objective To assess the scope and consistency of the construct dialysis adequacy as reported in randomised controlled trials in hemodialysis, and evaluate whether these align to the insights and understanding of this construct by patients. Methods To assess scope and consistency of dialysis adequacy by professionals, we performed a systematic review searching the Cochrane Central Register of Controlled Trials (CENTRAL) up to July 2017. We identified all randomised controlled trails (RCT) including patients on hemodialysis and reporting dialysis adequacy, adequacy or adequacy of dialysis and extracted and classified all reported outcomes. To explore interpretation and meaning of the construct of adequacy by patients, we conducted 11 semi-structured interviews with HD patients using thematic analysis. Belgian registration number B670201731001. Findings From the 31 included trials, we extracted and classified 98 outcome measures defined by the authors as adequacy of dialysis, of which 94 (95%) were biochemical, 3 (3%) non-biochemical surrogate and 2 (2%) patient-relevant. The three most commonly reported measures were all biochemical. None of the studies defined adequacy of dialysis as a patient relevant outcome such as survival or quality of life. Patients had a substantially different understanding of the construct dialysis adequacy than the biochemical interpretation reported in the literature. Being alive, time spent while being on dialysis, fatigue and friendliness of staff were the most prominent themes that patients linked to the construct of dialysis adequacy. Conclusion Adequacy of dialysis as reported in the literature refers to biochemical outcome measures, most of which are not related with patient relevant outcomes. For patients, adequate dialysis is a dialysis that enables them to spend as much quality time in their life as possible.
Collapse
|
7
|
Locatelli F, Carfagna F, Del Vecchio L, La Milia V. Haemodialysis or haemodiafiltration: that is the question. Nephrol Dial Transplant 2018; 33:1896-1904. [DOI: 10.1093/ndt/gfy035] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
Affiliation(s)
- Francesco Locatelli
- Department of Nephrology and Dialysis, Alessandro Manzoni Hospital ASST Lecco, Lecco, Italy
| | - Fabio Carfagna
- Department of Nephrology and Dialysis, Alessandro Manzoni Hospital ASST Lecco, Lecco, Italy
| | - Lucia Del Vecchio
- Department of Nephrology and Dialysis, Alessandro Manzoni Hospital ASST Lecco, Lecco, Italy
| | - Vincenzo La Milia
- Department of Nephrology and Dialysis, Alessandro Manzoni Hospital ASST Lecco, Lecco, Italy
| |
Collapse
|
8
|
Yin P, Song Y, Li J. Soluble transferrin receptor as a marker of erythropoiesis in patients undergoing high-flux hemodialysis. Bosn J Basic Med Sci 2017; 17:333-338. [PMID: 28446125 DOI: 10.17305/bjbms.2017.1972] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 04/16/2017] [Accepted: 04/16/2017] [Indexed: 11/16/2022] Open
Abstract
Anemia is a common complication in chronic kidney disease (CKD) patients receiving hemodialysis. The effect of high-flux dialysis (HFD) on anemia remains unclear. This prospective study aimed to evaluate the effect of HFD on anemia, and the potential of soluble transferrin receptor (sTfR) as a marker of iron status and erythropoiesis in CKD patients on hemodialysis. Forty patients, who switched from conventional low-flux dialysis to HFD for 12 months, were enrolled in this study. The levels of sTfR, hemoglobin (Hb), iron, and nutritional markers, as well as the dose of recombinant human erythropoietin (rhEPO) and use of chalybeate were determined at 0, 2, 6, and 12 months after starting HFD. HFD significantly increased the hemoglobin level and reduced sTfR level in CKD patients (p < 0.05). In addition, significant decreasing linear trends were observed for rhEPO dosage and chalybeate use (p < 0.05). The level of sTfR was positively correlated with the percentage of reticulocytes (RET%), rhEPO dose, and chalybeate use, while it was negatively correlated with Hb levels and total iron-binding capacity results (all p < 0.05). A univariate generalized estimating equation (GEE) model showed that the Hb level, RET%, rhEPO dose, and chalybeate use were the variables associated with sTfR levels. A multivariate GEE model showed that the time points when hemodialysis was performed were the variables associated significantly with sTfR levels. Overall, our findings suggest that HFD can effectively improve renal anemia in hemodialysis patients, and sTfR could be used as a marker of erythropoiesis in HFD patients.
Collapse
Affiliation(s)
- Pei Yin
- Department of Nephrology, First Affiliated Hospital of Chinese PLA General Hospital, Beijing, China.
| | | | | |
Collapse
|
9
|
Medium cut-off membranes - closer to the natural kidney removal function. Int J Artif Organs 2017; 40:328-334. [PMID: 28574113 PMCID: PMC6159847 DOI: 10.5301/ijao.5000603] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/26/2017] [Indexed: 01/31/2023]
|
10
|
Locatelli F, Andrulli S, Viganò SM, Concetti M, Urbini S, Giacchino F, Broccoli R, Aucella F, Cossu M, Conti P, Fattori L, Punzo G, Angelini D, Peruzzini M, Di Giulio S, Piroddi M, Galli F, Del Vecchio L. Evaluation of the Impact of a New Synthetic Vitamin E-Bonded Membrane on the Hypo-Responsiveness to the Erythropoietin Therapy in Hemodialysis Patients: A Multicenter Study. Blood Purif 2017; 43:338-345. [PMID: 28249254 DOI: 10.1159/000453442] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Accepted: 11/15/2016] [Indexed: 12/19/2022]
Abstract
BACKGROUND Oxidative stress has been related to hypo-response to erythropoiesis-stimulating agents (ESAs) in hemodialysis (HD) patients. The aim of this study was to verify whether vitamin E (ViE) on a synthetic polysulfone dialyzer can improve ESA responsiveness. METHODS This controlled, multicenter study involved 93 HD patients on stable ESA therapy, who were randomized to either ViE-coated polysulfone dialyzer or to a low-flux synthetic dialyzer. The primary outcome measure was the change in ESA resistance index (ERI) from baseline. RESULTS Mean ERI decreased in the ViE group by 1.45 IU/kg*g/dl and increased in the control group by 0.53 IU/kg*g/dl, with a mean difference of 1.98 IU/kg*g/dl (p = 0.001 after adjusting for baseline ERI, as foreseen by the study protocol). Baseline ERI was inversely related to its changes during follow-up only in the control group (R2 = 0.29). CONCLUSIONS The ViE dialyzer can improve ESA response in HD patients. Changes in ERI during follow-up are independent from baseline ERI only in the ViE group. Video Journal Club 'Cappuccino with Claudio Ronco' at http://www.karger.com/?doi=453442.
Collapse
Affiliation(s)
- Francesco Locatelli
- Department of Nephrology and Dialysis of Alessandro Manzoni Hospital, Lecco, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Lines SW, Carter AM, Dunn EJ, Lindley EJ, Tattersall JE, Wright MJ. A randomized controlled trial evaluating the erythropoiesis stimulating agent sparing potential of a vitamin E-bonded polysulfone dialysis membrane. Nephrol Dial Transplant 2013; 29:649-56. [PMID: 24293660 PMCID: PMC3938299 DOI: 10.1093/ndt/gft481] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Background Vitamin E (VE) bonded polysulfone dialysis membranes have putative erythropoiesis stimulating agent (ESA)-sparing and anti-inflammatory properties based on data from a small number of studies. We sought to investigate this in a large, prospective 12-month randomized controlled trial. Methods Two-hundred and sixty prevalent haemodialysis (HD) patients were randomized to dialysis with VE-bonded polysulfone membranes or non-VE-bonded equivalents. All ESA-dosing was performed by means of a computer-based anaemia management decision support system. Monthly data were used to calculate the ESA resistance index (ERI) and blood tests were performed at baseline, 6 and 12 months for measurement of C-reactive protein (CRP) levels. Results Of the 260 patients, 123 were randomized to dialysis with the VE-membrane and 12-month data was available for 220 patients. At the study population level, no beneficial effect of the VE membranes on the ERI or CRP levels was observed. Post hoc analyses indicated that there was a significant fall in ERI for patients with the highest baseline ESA resistance dialysed with the VE (9.28 [7.70–12.5] versus 7.70 [5.34–12.7] IU/week/kg/g/dL Hb, P = 0.01) but not the control membranes (9.45 [7.62–12.3] versus 8.14 [4.44–15.6] IU/week/kg/g/dL Hb, P = 0.41); this was not attributable to changes in CRP levels. Conclusions Wholesale switching of all chronic HD patients to dialysis with VE-bonded polysulfone membranes appears not to be associated with improvements in ESA-responsiveness or CRP. These membranes may have utility in patients with heightened ESA resistance.
Collapse
Affiliation(s)
- Simon W Lines
- Department of Nephrology, St. James's University Hospital, Leeds, UK
| | | | | | | | | | | |
Collapse
|
12
|
Susantitaphong P, Siribamrungwong M, Jaber BL. Convective therapies versus low-flux hemodialysis for chronic kidney failure: a meta-analysis of randomized controlled trials. Nephrol Dial Transplant 2013; 28:2859-74. [PMID: 24081858 DOI: 10.1093/ndt/gft396] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Although convective therapies have gained popularity for the optimal removal of uremic solutes, their benefits and potential risks have not been fully elucidated. We conducted a meta-analysis of all randomized controlled trials comparing convective therapies with low-flux hemodialysis in patients with chronic kidney failure. METHODS We performed a literature search using MEDLINE (inception-December 2012), Cochrane Central Register of Controlled Trials, ClinicalTrials.gov, scientific abstracts from meetings and bibliographies of retrieved articles. Randomized controlled trials comparing the effect of convective therapies including high-flux hemodialysis, hemofiltration or hemodiafiltration versus low-flux hemodialysis were included. Random-effects model meta-analyses were used to examine continuous and binary outcomes. RESULTS Sixty-five (29 crossover and 36 parallel-arm) trials were identified (n = 12 182). Convective therapies resulted in a decrease in all-cause mortality [relative risk (RR) 0.88; 95% confidence interval (CI) 0.76, 1.02, P = 0.09], cardiovascular mortality (RR 0.84; 95% CI 0.71, 0.98, P = 0.03), all-cause hospitalization (RR 0.91; 95% CI 0.82, 1.01; P = 0.08) and therapy-related hypotension (RR 0.55, 95% CI 0.35, 0.87, P = 0.01). Convective therapies also resulted in an increase in the clearance of several low-molecular-weight (urea, creatinine and phosphate), middle-sized (β-2 microglobulin and leptin) and protein-bound (homocysteine, advanced glycation end-products and pentosidine) solutes and a decrease in inflammatory markers (interleukin-6). There was no impact of convective therapies on cardiac morphological and functional parameters, and blood pressure and anemia parameters. CONCLUSIONS Although convective therapies are associated with improved clearance of uremic solutes, the potential long-term benefits of specific convective modalities require further study.
Collapse
Affiliation(s)
- Paweena Susantitaphong
- Department of Medicine, Division of Nephrology, Kidney and Dialysis Research Laboratory, St. Elizabeth's Medical Center, Boston, MA, USA
| | | | | |
Collapse
|
13
|
Badve SV, Beller EM, Cass A, Francis DP, Hawley C, Macdougall IC, Perkovic V, Johnson DW. Interventions for erythropoietin-resistant anaemia in dialysis patients. Cochrane Database Syst Rev 2013; 2013:CD006861. [PMID: 23979995 PMCID: PMC11663500 DOI: 10.1002/14651858.cd006861.pub3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
BACKGROUND People living with end-stage kidney disease (ESKD) often develop anaemia. Erythropoiesis-simulating agents (ESAs) are often given to people living with ESKD to maintain haemoglobin at a level to minimise need for transfusion. However, about 5% to 10% of patients with ESKD exhibit resistance to ESAs, and observational studies have shown that patients requiring high doses of ESA are at increased risk of mortality. OBJECTIVES This review aimed to study the effects of interventions for the treatment of ESA-resistant anaemia in people with ESKD. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE for randomised controlled trials (RCT) that involved participants with ESKD on dialysis or who were pre-dialysis patients with chronic kidney disease (stage 5). Date of last search: April 2013. SELECTION CRITERIA ESA resistance was defined as failure to achieve or maintain haemoglobin/haematocrit levels within the desired target range despite appropriate ESA doses (erythropoietin ≥ 450 U/kg/wk intravenously or ≥ 300 U/kg/wk subcutaneously; darbepoetin ≥ 1.5 µg/kg/wk) in people who were not nutritionally deficient, or who had haematological or bleeding disorders. Extended inclusion criteria for ESA hyporesponsive state were: erythropoietin dose ≥ 300 U/kg/wk and ≥ 150 U/kg/wk for intravenous administration; or ≥ 200 U/kg/wk and ≥ 100 U/kg/wk for subcutaneous administration; or darbepoetin dose ≥ 1.0 µg/kg/wk). DATA COLLECTION AND ANALYSIS Two authors independently assessed study quality and extracted data. Statistical analyses were performed using a random effects model and results expressed as risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI). MAIN RESULTS Titles and abstracts of 521 records were screened, of which we reviewed 99 from the full text. Only two studies matched our inclusion criteria. One study compared intravenous vitamin C versus no study medication for six months in 42 ESKD patients on haemodialysis who required intravenous erythropoietin (dose ≥ 450 U/kg/wk). The other included study compared high-flux dialyser versus low-flux dialyser for six months in 48 haemodialysis patients who required subcutaneous erythropoietin (dose ≥ 200 U/kg/wk). Because interventions differed, data could not be combined for quantitative meta-analysis. AUTHORS' CONCLUSIONS There was inadequate evidence identified to inform recommendation of any intervention to ameliorate ESA hyporesponsiveness. Adequately powered RCTs are required to establish the safety and efficacy of interventions to improve responsiveness to ESA therapy.
Collapse
Affiliation(s)
- Sunil V Badve
- Princess Alexandra HospitalDepartment of NephrologyWoolloongabbaQLDAustralia4102
| | - Elaine M Beller
- Bond UniversityFaculty of Health Sciences and MedicineGold CoastQLDAustralia4229
| | - Alan Cass
- The George Institute for Global HealthRenal and Metabolic DivisionLevel 10, King George V BuildingRoyal Prince Alfred HospitalCamperdownNSWAustralia2050
| | - Daniel P Francis
- Queensland HealthCentral Regional Services, Division of the CHOStafford DCQLDAustralia4053
| | - Carmel Hawley
- Princess Alexandra HospitalDepartment of NephrologyWoolloongabbaQLDAustralia4102
| | | | - Vlado Perkovic
- The George Institute for Global HealthRenal and Metabolic DivisionLevel 10, King George V BuildingRoyal Prince Alfred HospitalCamperdownNSWAustralia2050
| | - David W Johnson
- Princess Alexandra HospitalDepartment of NephrologyWoolloongabbaQLDAustralia4102
| | | |
Collapse
|
14
|
Palmer SC, Rabindranath KS, Craig JC, Roderick PJ, Locatelli F, Strippoli GFM. High-flux versus low-flux membranes for end-stage kidney disease. Cochrane Database Syst Rev 2012; 2012:CD005016. [PMID: 22972082 PMCID: PMC6956628 DOI: 10.1002/14651858.cd005016.pub2] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Clinical practice guidelines regarding the use of high-flux haemodialysis membranes vary widely. OBJECTIVES We aimed to analyse the current evidence reported for the benefits and harms of high-flux and low-flux haemodialysis. SEARCH METHODS We searched Cochrane Renal Group's specialised register (July 2012), the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (1948 to March 2011), and EMBASE (1947 to March 2011) without language restriction. SELECTION CRITERIA We included randomised controlled trials (RCTs) that compared high-flux haemodialysis with low-flux haemodialysis in people with end-stage kidney disease (ESKD) who required long-term haemodialysis. DATA COLLECTION AND ANALYSIS Data were extracted independently by two authors for study characteristics (participants and interventions), risks of bias, and outcomes (all-cause mortality and cause-specific mortality, hospitalisation, health-related quality of life, carpal tunnel syndrome, dialysis-related arthropathy, kidney function, and symptoms) among people on haemodialysis. Treatment effects were expressed as a risk ratio (RR) or mean difference (MD), with 95% confidence intervals (CI) using the random-effects model. MAIN RESULTS We included 33 studies that involved 3820 participants with ESKD. High-flux membranes reduced cardiovascular mortality (5 studies, 2612 participants: RR 0.83, 95% CI 0.70 to 0.99) but not all-cause mortality (10 studies, 2915 participants: RR 0.95, 95% CI 0.87 to 1.04) or infection-related mortality (3 studies, 2547 participants: RR 0.91, 95% CI 0.71 to 1.14). In absolute terms, high-flux membranes may prevent three cardiovascular deaths in 100 people treated with haemodialysis for two years. While high-flux membranes reduced predialysis beta-2 microglobulin levels (MD -12.17 mg/L, 95% CI -15.83 to -8.51 mg/L), insufficient data were available to reliably estimate the effects of membrane flux on hospitalisation, carpal tunnel syndrome, or amyloid-related arthropathy. Evidence for effects of high-flux membranes was limited by selective reporting in a few studies. Insufficient numbers of studies limited our ability to conduct subgroup analyses for membrane type, biocompatibility, or reuse. In general, the risk of bias was either high or unclear in the majority of studies. AUTHORS' CONCLUSIONS High-flux haemodialysis may reduce cardiovascular mortality in people requiring haemodialysis by about 15%. A large well-designed RCT is now required to confirm this finding.
Collapse
Affiliation(s)
- Suetonia C Palmer
- Department of Medicine, University of Otago Christchurch, Christchurch, New Zealand.
| | | | | | | | | | | |
Collapse
|
15
|
Prospective Randomized Pilot Study on the Effects of Two Synthetic High-Flux Dialyzers on Dialysis Patient Anemia. Int J Artif Organs 2012; 35:346-51. [DOI: 10.5301/ijao.5000101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/24/2012] [Indexed: 11/20/2022]
Abstract
Purpose: Anemia in chronic kidney disease dialysis patients is a complex syndrome involving many causes. Adequate dialysis can contribute to its correction through many mechanisms, including the removal of molecules that may inhibit erythropoiesis. The aim of this pilot study was to evaluate the effect on renal anemia of two synthetic, high-flux dialyzers (polynephron vs. high-flux polysulphone). Methods: 20 dialysis patients (11 male; mean age: 72 years) were randomly assigned and studied for 6 months. There were 2 dropouts in each group. Each patient underwent 3 hemodialysis treatments per week without any difference in dialysis prescription. At T = 0 and T = 6 (after 6 months), instantaneous plasma clearances and reduction rates of small solutes, β2-microglobulin protein (β2-μ); hemoglobin (Hb), and iron pattern were measured. The effect on anemia was evaluated by calculating the Erythropoesis Stimulating Agent (ESA) doses and the Erythropoietin Resistance Index (ERI). Results: Kt/V increased between T0 and T6 in both groups. β2-μ pre-dialysis levels significantly decreased between T0 and T6 in both dialyzer groups (p<0.001 in both groups). The Hb levels increased between T0 and T6, but significantly only for the polynephron patient group (p = 0.006 and 0.142). ESA dose did not change significantly. The ERI decreased by 22.7% between T0 and T6 in the polynephron-group and increased by 14% in the others; these changes were not significant. Conclusions: High-flux filters improved Hb levels, although only significantly in the polynephron group, suggesting a possible different effect. The results should be interpreted with caution and tested in an appropriately powered, large, prospective, randomized control trial.
Collapse
|
16
|
Schneider A, Drechsler C, Krane V, Krieter DH, Scharnagl H, Schneider MP, Wanner C. The effect of high-flux hemodialysis on hemoglobin concentrations in patients with CKD: results of the MINOXIS study. Clin J Am Soc Nephrol 2011; 7:52-9. [PMID: 22096040 DOI: 10.2215/cjn.02710311] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND OBJECTIVES Hemodialysis treatment induces markers of inflammation and oxidative stress, which could affect hemoglobin levels and the response to erythropoietin use. This study sought to determine whether high-flux dialysis would help improve markers of renal anemia, inflammation, and oxidative stress compared with low-flux dialysis. DESIGN, SETTINGS, PARTICIPANTS, & MEASUREMENTS In a prospective, controlled study, 221 patients undergoing maintenance hemodialysis and receiving darbepoetin-alfa treatment (mean age, 66 years; 55% male) from 19 centers were screened in a 20-week run-in period of low-flux hemodialysis with a synthetic dialysis membrane. Thereafter, 166 patients were enrolled and randomly assigned to receive a synthetic high-flux membrane or to continue on low-flux dialysis for 52 weeks. Data on myeloperoxidase, oxidized LDL, high-sensitivity C-reactive protein, and the Malnutrition Inflammation Score were collected at baseline and after 52 weeks; routine laboratory data, such as hemoglobin, ferritin, and albumin, and the use of darbepoetin-alfa, were also measured in the run-in period. Results After 52 weeks, the low-flux and the high-flux groups did not differ with respect to hemoglobin (mean ± SD, 11.7±0.9 g/dl versus 11.7±1.1 g/dl; P=0.62) or use of darbepoetin-alfa (mean dosage ± SD, 29.8±24.8 μg/wk versus 26.0±31.1 μg/wk; P=0.85). Markers of inflammation, oxidative stress, or nutritional status also did not differ between groups. CONCLUSION Over 1 year, high-flux dialysis had no superior effects on hemoglobin levels or markers of inflammation, oxidative stress, and nutritional status. These data do not support the hypothesis that enhanced convective toxin removal would improve patient outcome.
Collapse
Affiliation(s)
- Andreas Schneider
- Department of Medicine, Division of Nephrology, University Hospital Würzburg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
|
18
|
Mactier R, Hoenich N, Breen C. Renal Association Clinical Practice Guideline on haemodialysis. Nephron Clin Pract 2011; 118 Suppl 1:c241-86. [PMID: 21555899 DOI: 10.1159/000328072] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2009] [Accepted: 12/01/2009] [Indexed: 11/19/2022] Open
Affiliation(s)
- Robert Mactier
- Renal Services, NHS Greater Glasgow and Clyde and NHS Forth Valley.
| | | | | |
Collapse
|
19
|
Fouque D, Pelletier S, Guebre-Egziabher F. Have Recommended Protein and Phosphate Intake Recently Changed in Maintenance Hemodialysis? J Ren Nutr 2011; 21:35-8. [DOI: 10.1053/j.jrn.2010.10.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
20
|
Hallbauer J, Kreusch S, Klemm A, Wolf G, Rhode H. Long-term serum proteomes are quite similar under high- and low-flux hemodialysis treatment. Proteomics Clin Appl 2010; 4:953-61. [DOI: 10.1002/prca.201000051] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2010] [Revised: 08/11/2010] [Accepted: 09/07/2010] [Indexed: 11/06/2022]
|
21
|
Park JS, Kim GH, Kang CM, Lee CH. Application of cystatin C reduction ratio to high-flux hemodialysis as an alternative indicator of the clearance of middle molecules. Korean J Intern Med 2010; 25:77-81. [PMID: 20195407 PMCID: PMC2829420 DOI: 10.3904/kjim.2010.25.1.77] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2008] [Accepted: 02/16/2009] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND/AIMS Although high-flux (HF) dialyzers with enhanced membrane permeability are widely used in current hemodialysis (HD) practice, urea kinetic modeling is still being applied to indicate the adequacy of both low-flux (LF) and HF HD. In comparison with urea (molecular weight, 60 Da) and beta(2)-microglobulin (beta(2)MG, 12 kDa), cystatin C (CyC, 13 kDa) is a larger molecule that has attractive features as a marker for assessing solute clearance. We postulated that CyC might be an alternative for indicating the clearance of middle molecules (MMs), especially with HF HD. METHODS Eighty-nine patients were divided into LF and HF groups. Using single pool urea kinetic modeling, the urea reduction ratio (URR) and equilibrated Kt/V(urea) (eKt/V(urea)) were calculated. The serum CyC concentrations were measured using particle-enhanced immunonephelometry. As indices of the middle molecular clearance, the reduction ratios of beta(2)MG and CyC were calculated. RESULTS The beta(2)MG reduction ratio (beta(2)MGRR) and CyC reduction ratio (CyCRR) were higher in the HF group compared to the LF group. However, the URR and eKt/Vurea did not differ between the two groups. The CyCRR was significantly correlated with the eKt/V(urea) and beta(2)MGRR (r = 0.47 and 0.69, respectively, both p < 0.0001). CONCLUSIONS Compared to the LF dialyzer, the HF dialyzer removed CyC and beta(2)MG more efficiently. Unlike the beta(2)MGRR, the CyCRR was correlated with the eKt/V(urea) and beta(2)MGRR. This study suggests a role for the CyCRR as an alternative indicator of the removal of MMs.
Collapse
Affiliation(s)
- Joon-Sung Park
- Department of Internal Medicine, Hanyang University College of Medicine, Seoul, Korea
| | - Gheun-Ho Kim
- Department of Internal Medicine, Hanyang University College of Medicine, Seoul, Korea
| | - Chong Myung Kang
- Department of Internal Medicine, Hanyang University College of Medicine, Seoul, Korea
| | - Chang Hwa Lee
- Department of Internal Medicine, Hanyang University College of Medicine, Seoul, Korea
| |
Collapse
|
22
|
Vanholder RC, Glorieux GL, De Smet RV. Back to the future: middle molecules, high flux membranes, and optimal dialysis. Hemodial Int 2009; 7:52-7. [PMID: 19379341 DOI: 10.1046/j.1492-7535.2003.00004.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Middle molecules can be defined as compounds with a molecular weight (MW) above 500 Da. An even broader definition includes those molecules that do not cross the membranes of standard low-flux dialyzers, not only because of molecular weight, but also because of protein binding and/or multicompartmental behavior. Recently, several of these middle molecules have been linked to the increased tendency of uremic patients to develop inflammation, malnutrition, and atheromatosis. Other toxic actions can also be attributed to the middle molecules. In the present publication we will consider whether improved removal of middle molecules by large pore membranes has an impact on clinical conditions related to the uremic syndrome. The clinical benefits of large pore membranes are reduction of uremia-related amyloidosis; maintenance of residual renal function; and reduction of inflammation, malnutrition, anemia, dyslipidemia, and mortality. It is concluded that middle molecules play a role in uremic toxicity and especially in the processes related to inflammation, atherogenesis, and malnutrition. Their removal seems to be related to a better outcome, although better biocompatibility of membranes might be a confounding factor.
Collapse
Affiliation(s)
- Raymond C Vanholder
- Department of Internal Medicine, Nephrology Unit, University Hospital, Ghent, Belgium.
| | | | | |
Collapse
|
23
|
Ayli M, Ayli D, Azak A, Yüksel C, Atilgan G, Dede F, Akalin T, Abayli E, Çamlibel M. The Effect of High-Flux Hemodialysis on Dialysis-Associated Amyloidosis. Ren Fail 2009. [DOI: 10.1081/jdi-42868] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
|
24
|
Tiranathanagul K, Praditpornsilpa K, Katavetin P, Srisawat N, Townamchai N, Susantitaphong P, Tungsanga K, Eiam-Ong S. On-line Hemodiafiltration in Southeast Asia: A Three-year Prospective Study of a Single Center. Ther Apher Dial 2009; 13:56-62. [DOI: 10.1111/j.1744-9987.2009.00654.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
25
|
Pellicano R, Polkinghorne KR, Kerr PG. Reduction in β2-Microglobulin With Super-flux Versus High-flux Dialysis Membranes: Results of a 6-Week, Randomized, Double-blind, Crossover Trial. Am J Kidney Dis 2008; 52:93-101. [DOI: 10.1053/j.ajkd.2008.02.296] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2007] [Accepted: 02/12/2008] [Indexed: 11/11/2022]
|
26
|
Abstract
Approximately 5-10% of patients with chronic kidney disease demonstrate hyporesponsiveness to erythropoiesis-stimulating agents (ESA), defined as a continued need for greater than 300 IU/kg per week erythropoietin or 1.5 mug/kg per week darbepoetin administered by the subcutaneous route. Such hyporesponsiveness contributes significantly to morbidity, mortality and health-care economic burden in chronic kidney disease and represents an important diagnostic and management challenge. The commonest causes of ESA resistance are non-compliance, absolute or functional iron deficiency and inflammation. It is widely accepted that maintaining adequate iron stores, ideally by administering iron parenterally, is the most important strategy for reducing the requirements for, and enhancing the efficacy of ESA. There have been recent epidemiologic studies linking parenteral iron therapy to an increased risk of infection and atherosclerosis, although other investigations have refuted this. Inflammatory ESA hyporesponsiveness has been reported to be improved by a number of interventions, including the use of biocompatible membranes, ultrapure dialysate, transplant nephrectomy, ascorbic acid therapy, vitamin E supplementation, statins and oxpentifylline administration. Other variably well-established causes of ESA hyporesponsiveness include inadequate dialysis, hyperparathyroidism, nutrient deficiencies (vitamin B12, folate, vitamin C, carnitine), angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, aluminium overload, antibody-mediated pure red cell aplasia, primary bone marrow disorders, myelosuppressive agents, haemoglobinopathies, haemolysis and hypersplenism. This paper reviews the causes of ESA hyporesponsiveness and the clinical evidence for proposed therapeutic interventions. A practical algorithm for approaching the investigation and management of patients with ESA hyporesponsiveness is also provided.
Collapse
Affiliation(s)
- David W Johnson
- Department of Renal Medicine, University of Queensland at Princess Alexandra Hospital, Brisbane, Queensland, Australia.
| | | | | |
Collapse
|
27
|
Locatelli F, Del Vecchio L, Pozzoni P, Andrulli S. Dialysis adequacy and response to erythropoiesis-stimulating agents: what is the evidence base? Semin Nephrol 2007; 26:269-74. [PMID: 16949464 DOI: 10.1016/j.semnephrol.2006.05.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Despite an increase in the use and average dose of erythropoiesis-stimulating agents (ESA) over the past 15 years, a substantial percentage of patients still do not achieve hemoglobin targets recommended by international guidelines. A clear relationship among hemoglobin or hematocrit levels, ESA dose, and increase in dialysis dose has been pointed out by a number of prospective or retrospective studies. This is particularly true in patients receiving inadequate dialysis. Increasing attention also has been paid to the relationship between dialysis, increased inflammatory stimulus, and ESA response because dialysate contamination and low-compatible treatments may increase cytokine production and consequently inhibit erythropoiesis. The biocompatibility of dialysis membranes and flux are other important factors. However, in highly selected, adequately dialyzed patients without iron or vitamin depletion, the effect of these treatment modalities on anemia seems to be smaller than expected. The role of on-line treatments still is controversial given that it is still difficult to discriminate between the effect of on-line hemodiafiltration per se from that of an increased dialysis dose. Very preliminary results obtained with short or long nocturnal daily hemodialysis on anemia correction are encouraging.
Collapse
Affiliation(s)
- Francesco Locatelli
- The Department of Nephrology and Dialysis, Ospedale A. Manzoni, Lecco, Italy.
| | | | | | | |
Collapse
|
28
|
Abstract
The anemia of chronic kidney disease is associated with cardiovascular disease, decreased quality of life, and mortality. The introduction of recombinant human erythropoietin (rHuEPO) has transformed the management of this condition. However, a significant proportion of patients fail to respond to even high doses of rHuEPO. Several factors have been implicated in the hyporesponsiveness to rHuEPO. Iron deficiency, whether absolute or functional, is considered the most important, and maintenance of adequate iron stores reduces rHuEPO requirements among patients on hemodialysis. However, traditional indices of iron that are currently utilized may not reflect iron stores accurately, and there is also increasing concern regarding the potential long-term toxicity of parenteral iron therapy. Infection and inflammation also influence the response to rHuEPO, both by disruption of iron metabolism and by eliciting the release of cytokines that inhibit erythropoiesis. Oxidative stress may contribute to rHuEPO hyporesponsiveness directly by promoting lipid peroxidation in cell membranes, leading to increased erythrocyte fragility and reduced life span and also through its strong association with inflammation. Severe hyperparathyroidism can lead to a reduced number of erythroid progenitor cells. Inadequate dialysis dose, aluminum overload, nutritional factors such as deficiencies of carnitine, vitamin B12, folic acid, and vitamin C can also reduce the efficacy of rHuEPO therapy. Hyporesponsiveness to rHuEPO presents a challenge to both diagnosis and management in an era where optimizing response to rHuEPO is critical both in limiting the burgeoning costs of anemia management and improving clinical outcomes in the dialysis population.
Collapse
Affiliation(s)
- Christina Kwack
- Division of Nephrology, Department of Medicine, Tufts-New England Medical Center, Boston, Massachusetts 02111, USA
| | | |
Collapse
|
29
|
References. Am J Kidney Dis 2006. [DOI: 10.1053/j.ajkd.2006.03.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
30
|
Pozzoni P, Filippo S, Manzoni C, Locatelli F. The relevance of convection in clinical practice: A critical review of the literature. Hemodial Int 2006; 10 Suppl 1:S33-8. [PMID: 16441866 DOI: 10.1111/j.1542-4758.2006.01188.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Convective treatments (high-flux hemodialysis (HD), hemodiafiltration and hemofiltration) are characterized by enhanced removal of middle and large molecular weight solutes compared with conventional low-flux HD. As these molecules are claimed to play an important role in the genesis of many complications of chronic HD, the availability of these techniques represented an intriguing innovation and a possible means to improve the still poor prognosis of HD patients. Here we will critically review the most important published studies comparing convective treatments with low-flux HD on chronic morbidity, preservation of residual renal function, and long-term survival.
Collapse
Affiliation(s)
- Pietro Pozzoni
- Department of Nephrology and Dialysis, A. Manzoni Hospital, Lecco, Italy
| | | | | | | |
Collapse
|
31
|
MacLeod AM, Campbell MK, Cody JD, Daly C, Grant A, Khan I, Rabindranath KS, Vale L, Wallace SA. Cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease. Cochrane Database Syst Rev 2005; 2005:CD003234. [PMID: 16034894 PMCID: PMC8711594 DOI: 10.1002/14651858.cd003234.pub2] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND When the kidney fails the blood-borne metabolites of protein breakdown and water cannot be excreted. The principle of haemodialysis is that such substances can be removed when blood is passed over a semipermeable membrane. Natural membrane materials include cellulose or modified cellulose, more recently various synthetic membranes have been developed. Synthetic membranes are regarded as being more "biocompatible" in that they incite less of an immune response than cellulose-based membranes. OBJECTIVES To assess the effects of different haemodialysis membrane material in patients with end-stage renal disease (ESRD). SEARCH STRATEGY We searched MEDLINE, EMBASE, PreMEDLINE, HealthStar CINAHL, the Cochrane Central Register of Controlled Trials (CENTRAL), Biosis, SIGLE, CRIB, UK National Research Register and reference lists of relevant articles. We contacted biomedical companies, known investigators and handsearched selected journals and conference proceedings. Date of most recent search: June 2004. SELECTION CRITERIA All randomised controlled trials (RCTs) or quasi-RCTs comparing different haemodialysis membrane material in patients with ESRD. DATA COLLECTION AND ANALYSIS Two reviewers independently assessed the methodological quality of studies. Data was abstracted onto a standard form by one reviewer and checked by another. Relative Risk (RR) and weighted mean difference (WMD) with 95% confidence intervals (CI)) MAIN RESULTS: Thirty two studies were identified. Pre-dialysis ss(2) microglobulin concentrations were not significantly lower in patients treated with synthetic membranes (WMD -14.67, 95% CI -33.10 to 4.05). When analysed for change in ss(2) microglobulin, a fall was only noted with high-flux membranes. The incidence of amyloid was less in patients who were dialysed for six years with high-flux synthetic membranes (one study, RR 0.03, 95% CI 0.00 to 0.54). There was a significant difference in favour of the synthetic (high-flux) membrane in comparison to cellulose membranes for triglycerides (WMD -0.66; 95% CI -1.18 to -0.14) but not for modified cellulose membranes. Dialysis adequacy measured by Kt/V was marginally higher when cellulose membranes were used (WMD -0.10; 95% CI -0.16 to 0.04), whereas synthetic membranes achieved significantly higher Kt/V values when compared with modified cellulose membranes (WMD 0.20, 95% 0.11 to 0.29) . There were no data on quality of life measures. AUTHORS' CONCLUSIONS We found no evidence of benefit when synthetic membranes were compared with cellulose/modified cellulose membranes in terms of reduced mortality no reduction in dialysis-related adverse symptoms. Despite the relatively large number of RCTs undertaken in this area none of the included studies reported any measures of quality of life.
Collapse
Affiliation(s)
- Alison M MacLeod
- University of AberdeenDepartment of Medicine and TherapeuticsPolwarth BuildingForesterhillAberdeenScotlandUKAB25 2ZD
| | - Marion K Campbell
- University of AberdeenHealth Services Research UnitPolwarth BuildingForesterhillAberdeenScotlandUKAB25 2ZD
| | - June D Cody
- University of AberdeenCochrane Incontinence Review Group1st FloorHealth Sciences BuildingForesterhillAberdeenUKAB25 2ZD
| | - Conal Daly
- Western Infirmary GlasgowRenal UnitDumbarton RdGlasgowScotlandUKG11 6NT
| | - Adrian Grant
- University of AberdeenSchool of Medicine1st Floor, Health Sciences BuildingForesterhillAberdeenScotlandUKAB25 2ZD
| | - Izhar Khan
- University of AberdeenDepartment of Medicine and TherapeuticsPolwarth BuildingForesterhillAberdeenScotlandUKAB25 2ZD
| | | | - Luke Vale
- University of AberdeenHealth EconomicsHealth Services Research UnitMedical School Building, ForesterhillAberdeenUKAB25 2ZD
| | - Sheila A Wallace
- University of AberdeenAcademic Urology Unit1st Floor, Health Sciences BuildingForesterhillAberdeenScotlandUKAB25 2ZD
| | | |
Collapse
|
32
|
Ward RA. Protein-Leaking Membranes for Hemodialysis: A New Class of Membranes in Search of an Application? J Am Soc Nephrol 2005; 16:2421-30. [PMID: 15975998 DOI: 10.1681/asn.2005010070] [Citation(s) in RCA: 78] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
A new class of membranes that leak protein has been developed for hemodialysis. These membranes provide greater clearances of low molecular weight proteins and small protein-bound solutes than do conventional high-flux dialysis membranes but at the cost of some albumin loss into the dialysate. Protein-leaking membranes have been used in a small number of clinical trials. The results of these trials suggest that protein-leaking membranes improve anemia correction, decrease plasma total homocysteine concentrations, and reduce plasma concentrations of glycosylated and oxidized proteins. However, it is not clear yet that routine use of protein-leaking membranes is warranted. Specific uremic toxins that are removed by protein-leaking membranes but not conventional high-flux membranes have not been identified. It is also unclear whether protein-leaking membranes offer benefits beyond those obtained with conventional high-flux membranes used in convective therapies, such as hemofiltration and hemodiafiltration. Finally, the amount of albumin loss that can be tolerated by hemodialysis patients in a long-term therapy has yet to be determined. Protein-leaking membranes offer a new approach to improving outcomes in hemodialysis, but whether their benefits will outweigh their disadvantages will require more basic and clinical research.
Collapse
Affiliation(s)
- Richard A Ward
- Kidney Disease Program, Department of Medicine, University of Louisville, 615 S. Preston Street, Louisville, KY 40202-1718, USA.
| |
Collapse
|
33
|
Michelis R, Sela S, Kristal B. Intravenous iron-gluconate during haemodialysis modifies plasma β2-microglobulin properties and levels. Nephrol Dial Transplant 2005; 20:1963-9. [PMID: 15956071 DOI: 10.1093/ndt/gfh907] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Intravenous iron replacement therapy is routinely used for correction of anaemia in patients with end-stage renal failure. Free or labile iron, present both in parenteral iron formulations and in blood of haemodialysis (HD) patients, has the potential to induce severe oxidative processes. This study evaluated the acute in vivo effect of intravenous iron administration on the oxidation of plasma beta2-microglobulin (beta2m) and on its plasma levels after HD. METHODS Iron-gluconate was administered intravenously to 14 patients receiving HD with low-flux cellulose-triacetate membranes during the first hour of the 4 h HD treatment. Each patient underwent three different dialysis treatments, during which an infusion of 62.5, 125 or 0 mg (control) of iron-gluconate was administered in random order. Plasma beta2m levels and iron parameters were monitored immediately before and after each HD treatment. The molecular isoforms of beta2m were studied by two-dimensional gel electrophoresis and western analysis. Levels of oxidized beta2m were evaluated by reaction with 2,4-dinitrophenylhydrazine and western analysis. RESULTS Both doses of iron-gluconate caused remarkable changes in the molecular properties of beta2m, including shift in isoelectric point, molecular mass and degree of oxidation. Iron administration also limited the decline in plasma beta2m levels to <7.5%, compared with 27.9+/-2.7% during HD without iron. CONCLUSIONS Intravenous iron-gluconate led to a characteristic increase in molecular weight and in negative charge of beta2m, both of which can be assumed to be consistent with reduced membrane sieving coefficients and membrane adsorption, and thus with reduced clearance of beta2m.
Collapse
Affiliation(s)
- Regina Michelis
- Eliachar Research Laboratory, Western Galilee Hospital, Nahariya, Israel
| | | | | |
Collapse
|
34
|
Richardson D, Lindley EJ, Bartlett C, Will EJ. A randomized, controlled study of the consequences of hemodialysis membrane composition on erythropoietic response. Am J Kidney Dis 2003; 42:551-60. [PMID: 12955684 DOI: 10.1016/s0272-6386(03)00788-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND Membrane biocompatibility has long been thought to be relevant to hemodialysis outcomes and, possibly, renal anemia. METHODS We performed a randomized, controlled, single-center study comparing the consequences on renal anemia of 2 dialyzers of equivalent performance, but different composition, during 7 months. Two hundred eleven patients of an unselected dialysis population of 235 patients gave informed consent to undergo random assignment to either group A (SF170E; modified cellulose triacetate/midflux membrane; Nipro, Osaka, Japan) or group B (HF80LS; polysulfone/high-flux membrane; Fresenius, Bad Homburg, Germany). Anemia management was identical in both treatment groups and followed strict clinical protocols managed by computer algorithms. Dialysis adequacy, hemoglobin (Hb) level, ferritin level, percentage of red blood cell hypochromicity, C-reactive protein (CRP) level, and intravenous iron and epoetin doses were monitored monthly. RESULTS One hundred seventy-seven patients completed the 7-month study. Equilibrated Kt/V increased in both groups. Hb outcome improved overall, but did not differ between the 2 study groups. Epoetin dose was not significantly different after 7 months compared with baseline in either group. Hb level, epoetin dose, iron status, CRP level, dialysis Kt/V, and residual renal function did not differ between the 2 groups. A slight but significant negative correlation was identified between dialysis Kt/V and Hb level in the population as a whole (Spearman's correlation, -0.16; P = 0.04). CONCLUSION No significant epoetin-sparing effect was identified through the use of the high-flux polysulfone HF80LS membrane over the modified cellulose triacetate SF170E membrane. Although not a primary outcome for this study, there was a suggestion of benefit of improved Hb level, without increased need for epoetin, through increasing delivered dialysis dose.
Collapse
Affiliation(s)
- Donald Richardson
- Department of Renal Medicine, St James's University Hospital, Leeds, UK.
| | | | | | | |
Collapse
|
35
|
Krieter DH, Canaud B. High permeability of dialysis membranes: what is the limit of albumin loss? Nephrol Dial Transplant 2003; 18:651-4. [PMID: 12637630 DOI: 10.1093/ndt/gfg054] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
36
|
Merello Godino JI, Rentero R, Orlandini G, Marcelli D, Ronco C. Results from EuCliD (European Clinical Dialysis Database): impact of shifting treatment modality. Int J Artif Organs 2002; 25:1049-60. [PMID: 12487392 DOI: 10.1177/039139880202501103] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The use of biocompatible high-flux membranes is more efficient than low-flux membranes in controlling a number of hemodialysis-related diseases. The aim of this cooperative study was to evaluate the 6-month effect of a switch from low- to high-flux dialysers on patients treated in 39 Spanish dialysis centres. METHODS The clinical data used in this analysis were prospectively collected by the EuCliD database, developed to monitor the quality of treatment delivered in a large network of European Dialysis Centres. Inclusion criteria for the study were the condition of end-stage renal disease (ESRD) on chronic hemodialysis and low-flux dialysis for at least six months before the switch to high-flux dialysis. Of 1,543 patients enrolled in the study between 2000 and 2001, 1,046 patients were considered for the analysis. 497 patients were excluded because they did not complete the follow-up. Outcome measures were the reduction of pre-dialysis beta-2 microglobulin, the improvement of anemia or reduction in rHu-EPO dose required to maintain best correction of anemia, reduction of inflammatory parameters (CRP), improvement in lipid profile (Total and HDL cholesterol, tryglycerides), maintenance of nutritional status. Albumin and "dry" (post-hemodialysis) body weight were both evaluated as nutritional indexes. RESULTS During the six months of high-flux hemodialysis, there was a significant increase in hemoglobin (from 11.55 +/- 1.41 to 11.88 +/- 1.43 g/L; p < 0.001). Considering the temporarily untreated patients on a 0 U/week dose, erythropoietin remained stable (from 5,670 +/- 4,199 to 5,657 +/- 4,411 U/week). During the second part of the follow-up, the lipid profile significantly improved (Fig. 3). Total cholesterol and triglycerides decreased significantly (p < 0.001), while HDL cholesterol increased (p = 0.006). Calculated levels of LDL cholesterol also significantly decreased (p = 0.001). Dry body weight remained stable (64.7 +/- 11.9 vs. 64.7 +/- 12.0 kg) as well as in albumin levels (3.93 +/- 0.43 vs. 3.94 +/- 0.43 g/dL) between the two modalities of treatment. The level of beta2-microglobulin significantly decreased during high-flux dialysis (33.5 +/- 14.4 vs. 26.3 +/- 8.6 mg/dL, p < 0.001). CONCLUSION All above mentioned results may have as a common denominator an improved blood purification from uremic toxins and a reduced level of chronic sub-clinical inflammation. All together, these results seem to confirm the superiority of high-flux dialysis in terms of clinical and physiological outcomes.
Collapse
|
37
|
Locatelli F, Manzoni C, Di Filippo S. The importance of convective transport. KIDNEY INTERNATIONAL. SUPPLEMENT 2002:115-20. [PMID: 11982825 DOI: 10.1046/j.1523-1755.61.s80.21.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Despite technological advances in dialysis equipment and modalities, survival, morbidity, and quality of life of hemodialysis patients are still severely affected by acute intradialytic and long-term complications, possibly related to the treatment itself. Convective treatments, such as high-flux hemodialysis, hemodiafiltration, and hemofiltration are increasingly suggested as further improvements over standard diffusive hemodialysis. The membranes used for these techniques are high-flux semisynthetic and synthetic membranes. Characteristics of these membranes are high permeability, which allows convective removal of water and electrolytes and higher clearance of middle and large molecular weight solutes, and high biocompatibility, which minimizes the "inflammatory response" secondary to interactions between blood and the artificial material of the hemodialysis system. METHODS With the specific aim of verifying the superiority of convective treatments in reducing morbidity and mortality, we performed a review of the published literature. RESULTS Some epidemiological studies suggest that convective treatments reduce morbidity and mortality among dialysis patients. However, the results of the published prospective randomized controlled trials are conflicting. Moreover, since convective treatments are usually performed with synthetic biocompatible membranes, it is hard to separate the effect of convection from the effect of biocompatibility. CONCLUSIONS To finally assess the effect of high-flux membranes on morbidity and mortality, the results of two randomized, controlled clinical trials (HEMO study and MPO study) specifically designed with this aim are needed.
Collapse
|
38
|
Kerr PG. High-flux dialysers*. Nephrology (Carlton) 2002. [DOI: 10.1046/j.1440-1797.2002.00079.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
39
|
Locatelli F, Del Vecchio L, Andrulli S. The modality of dialysis treatment: does it influence the response to erythropoietin treatment? Nephrol Dial Transplant 2001; 16:1971-4. [PMID: 11572880 DOI: 10.1093/ndt/16.10.1971] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
40
|
Basile C, Giordano R, Montanaro A, De Maio PD, De Padova FD, Marangi AL, Semeraro A. Effect of acetate-free biofiltration on the anaemia of haemodialysis patients: a prospective cross-over study. Nephrol Dial Transplant 2001; 16:1914-9. [PMID: 11522879 DOI: 10.1093/ndt/16.9.1914] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND The discussion about the pathogenesis of renal anaemia, whether it is primarily due to relative erythropoietin (Epo) deficiency or to uraemic inhibition of erythropoiesis, is still open. Although it has so far not been possible to identify or isolate a substance retained in uraemia with a suppressive action directed specifically against red-cell production, dialysis therapy can improve the effect of both residual endogenous Epo and exogenous rHuEpo. To what extent the mode and/or the dose of dialysis influence Epo efficacy is as yet poorly understood. METHODS This study was performed as a single-centre trial. The protocol included a run-in period of 4 months followed by a prospective cross-over study including 6 months each of acetate-free biofiltration (AFB) with a high-flux biocompatible membrane and standard bicarbonate dialysis (BD) with a low-flux cellulosic membrane in a random sequence. AFB is a haemodiafiltration technique based on a continuous post-dilution infusion of a sterile isotonic bicarbonate solution. At the start of the run-in period (and for the entire length of the study), rHuEpo administration was withdrawn; patients whose haemoglobin (Hb) levels dropped at a level <8.0 g/dl at one single monthly check, had to be withdrawn from the study. A blood sample was collected every month for the blood gas analysis and for the determination of blood urea nitrogen, serum creatinine, sodium, potassium, calcium, phosphorus, Hb, erythrocyte, reticulocyte, leukocyte and thrombocyte cell counts, mean globular volume and haematocrit. An equilibrated single pool Kt/V(urea)>1.2 was mandatory in both treatment modalities. Serum iron, total iron-binding capacity, and ferritin were checked every 3 months. RESULTS Twenty-three of 137 haemodialysis patients were considered eligible for the trial on the basis of the entry criteria. Of these, 15 volunteered and only 10 completed the study. No significant differences in the haematological indices, in the biochemical parameters assessing body iron stores, or in i.v. iron dosage was observed when comparing AFB with BD treatments. The equilibrated single pool Kt/V(urea) was always >1.2 and in no case was a significant difference observed when comparing AFB with BD treatments. Treatment time was significantly different between the two treatments (262+/-2 min in BD and 249+/-1 in AFB, P<0.0001). Neither pre- nor post-dialysis systolic and diastolic blood pressures, pre-dialysis serum bicarbonate and pH, pre-dialysis serum sodium, potassium, calcium, or phosphorus were significantly different when comparing the two treatment modalities. All 10 patients completed the 1-year follow-up without any major side-effects. CONCLUSIONS Our study did not show any improvement of anaemia when treating a highly selected patient group, in the absence of any Epo therapy, with AFB compared with standard BD. Even though these conclusions cannot be extended in toto to the entire dialysis population, in which there is a large proportion of Epo-treated patients with Hb levels around 11 g/dl, we may nevertheless conclude that when patients are well selected, adequately dialysed, and not iron- and/or vitamin-depleted, the effect of a haemodiafiltration technique with a high-flux biocompatible membrane is less than might be expected from the results of uncontrolled studies.
Collapse
Affiliation(s)
- C Basile
- Nephrology and Dialysis Unit, Hospital of Martina Franca, Italy
| | | | | | | | | | | | | |
Collapse
|
41
|
Fourtounas C, Kopelias I, Dimitriadis G, Agroyannis B. The impact of dialyzers on the anaemia of haemodialysis patients. Nephrol Dial Transplant 2001; 16:1077-8. [PMID: 11328925 DOI: 10.1093/ndt/16.5.1077] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
42
|
Sherman RA. Briefly Noted. Semin Dial 2001. [DOI: 10.1046/j.1525-139x.2001.00024.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
43
|
MacLeod A, Daly C, Khan I, Vale L, Campbell M, Wallace S, Cody J, Donaldson C, Grant A. Comparison of cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease. Cochrane Database Syst Rev 2001:CD003234. [PMID: 11687058 DOI: 10.1002/14651858.cd003234] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND When the kidney fails the blood borne metabolites of protein breakdown and water cannot be excreted. The principle of haemodialysis is that such substances can be removed when blood is passed over a semipermeable membrane. Natural membrane materials can be used including cellulose or modified cellulose, more recently various synthetic membranes have been developed. Synthetic membranes are regarded as being more "biocompatible" in that they incite less of an immune response than cellulose-based membranes. OBJECTIVES To assess the effects of different haemodialysis membrane material in patients with end-stage renal disease (ESRD). SEARCH STRATEGY We searched Medline (1966 to December 2000), Embase (1981 to November 2000), PreMedline (29 November 2000), HealthStar (1975 to December 2000), Cinahl (1982 to October 2000), The Cochrane Controlled Trials Register (Issue 1, 1996), Biosis (1989 to June 1995), Sigle (1980 to June 1996), Crib (10th edition, 1995), UK National Research Register (September 1996), and reference lists of relevant articles. We contacted biomedical companies, investigators and we hand searched Kidney International (1980 to 1997). Date of the most recent searches: November 2000. SELECTION CRITERIA All randomised or quasi-randomised clinical trials comparing different haemodialysis membrane material in patients with ESRD. DATA COLLECTION AND ANALYSIS Two reviewers independently assessed the methodological quality of studies. Data was abstracted from included studies onto a standard form by one reviewer and checked by another. MAIN RESULTS Twenty seven studies met our inclusion criteria and where possible data from these were summated by meta-analyses (Peto's odds ratio (OR) and weighted mean difference (WMD) with 95% confidence intervals (CI)). Twenty two outcome measures were sought in 10 broad areas. For two (number of episodes of significant infection per year and quality of life) no data were available. For the comparison of cellulose with synthetic membranes, data for 12/20 outcome measures were available in only a single trial. For modified cellulose and synthetic membranes, data for three outcome measures were available in one trial only and for 12 of the outcomes no data were found, crossover studies were analysed separately and studies which randomised by patient yet analysed by dialysis sessions adjusted for clustering. Pre-dialysis beta2 microglobulin concentrations were significantly lower at the end of the studies in patients treated with synthetic membranes (WMD - 14.5; 95% CI -17.4 to -11.6). One crossover study showed a lowering of beta2 microglobulin when low flux synthetic membranes were used. When analysed for a change in beta2 microglobulin across a trial a fall was only noted when high flux membranes were used. In one very small study the incidence of amyloid was less in patients who were dialysed for six years with high flux synthetic membranes (OR 0.05; 95% CI 0.01 to 0.18). In the single study which measured triglyceride values there was a significant difference in favour of the synthetic (high flux) membrane (WMD -0.66; 95% CI -1.18 to -0.14). Serum albumin was higher in patients treated with synthetic membranes (both low and high flux) although this just bordered statistical significance (WMD -0.09; 95% CI -0.18 to 0.00). Dialysis adequacy measured by Kt/V was marginally higher when cellulose membranes were used (WMD 0.10; 95% CI 0.04 to 0.16). There was no significant difference between these membranes for any of the other clinical outcomes measures but confidence intervals were generally wide. No differences were found between modified cellulose and synthetic membranes although many fewer trials were carried out for this comparison. REVIEWER'S CONCLUSIONS For clinical practice This systematic literature review has generated no evidence of benefit when synthetic membranes were used compared with cellulose/modified cellulose membranes in terms of reduced mortality nor reduction in dialysis related adverse symptoms. Despite the relatively large number of RCTs undertaken in this area none of the included studies reported any measures of quality of life. End-of-study beta2 microglobulin values, and possibly the development of amyloid disease, were less in patients treated with synthetic membranes compared with cellulose membranes. Plasma triglyceride values were also lower with synthetic membranes in the single study that measured this outcome. Differences in these outcomes may have reflected the high flux of the synthetic membrane. Serum albumin was higher when synthetic membranes of both high and low flux were used. Kt/V and urea reduction ratio were higher when cellulose or modified cellulose membranes were used in the few studies that measured these outcomes. We are hesitant to recommend the universal use of synthetic membranes for haemodialysis in patients with ESRD because of; the small number of trials (particularly for modified cellulose membranes, most with low patient numbers), the heterogeneity of many of the trials compared, the variations in membrane flux, the differences in exclusion criteria, particularly relating to comorbidity and the relative lack of patient-centred outcomes studied. Such evidence as we have favours synthetic membranes but even if we assume extra benefit it may be at considerable cost, particularly if high flux synthetic membranes were to be used. For further research A further systematic review of RCTs comparing high and low flux haemodialysis membranes, subgrouped according to membrane composition (cellulose, modified cellulose, synthetic) and reporting clinical outcomes of major importance to patients needs to be undertaken. Further pragmatic RCTs are required to compare the different dialysis membranes available. We recommend that they: - Take into account other properties including flux as well as the material from which the membrane is made and test modified cellulose membranes as well as standard ones. - Record an agreed minimum dataset on primary outcomes of major importance to patients. - Explicitly record whether symptoms are patient- or staff-reported recognising that generally patient reporting will be more appropriate for evaluating effectiveness but staff reported data may be necessary for calculating the cost of treating complications. - Be multi-centre (and possibly multinational) to have sufficient patients to complete the study to allow for a considerable number of withdrawals and dropouts. - Have sufficient length of follow up to draw conclusions for important clinical outcome measures and continue to follow patients who have renal transplants. - Include older patients and those with comorbid illnesses and take into account age and comorbidity when assessing outcomes (possibly by stratification at trial entry). - Carry out, in parallel, an economic evaluation of the different policies being compared in the trial.
Collapse
Affiliation(s)
- A MacLeod
- Medicine and Therapeutics, University of Aberdeen, Polwarth Building, Foresterhill, Aberdeen, Scotland, UK, AB25 2ZD.
| | | | | | | | | | | | | | | | | |
Collapse
|
44
|
|