1
|
Zitsch BP, Cahoy KM, Urban ND, Buckner BC, Garvin KL. Highly Cross-Linked Polyethylene in Patients 50 Years of Age and Younger: A 20-year Follow-Up Analysis. J Arthroplasty 2024:S0883-5403(24)00267-5. [PMID: 38548239 DOI: 10.1016/j.arth.2024.03.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 03/15/2024] [Accepted: 03/18/2024] [Indexed: 04/21/2024] Open
Abstract
BACKGROUND Highly cross-linked polyethylene (HXLPE) has been an excellent bearing for total hip arthroplasty (THA) due to improved wear characteristics compared to conventional materials. Patients 50 years of age or younger are at high risk for wear-related complications of their THA, and few studies have followed these patients who have HXPLE into the third decade. METHODS In a retrospective review of 88 consecutive THAs performed in 77 patients aged 50 years and younger (mean 41; range, 20 to 50), in which HXLPE was utilized, they were evaluated for their clinical and radiographic results at an average of 20-year follow-up (range, 18 to 24). The current study reports on longer-term follow-up from our previously published series at shorter follow-up times. Patients were categorized by femoral head material: cobalt chrome (n = 14), ceramic (n = 30), and oxidized zirconium (n = 22) and by femoral head size: 26 mm (n = 12), 28 mm (n = 46), and 32 mm (n = 8). Harris Hip Scores were collected preoperatively and at the most recent follow-up. Radiographs were evaluated for linear and volumetric wear, radiolucent lines, and osteolysis. RESULTS Mean Harris Hip Scores improved from 47.1 (standard deviation [SD] 8.8) preoperatively to 92.0 (SD 7.7) (P < .0001) at 20-year follow-up. There was one hip that was revised for recurrent instability, and no hip demonstrated radiographic evidence of loosening or osteolysis. The mean polyethylene linear wear rate was 0.017 (SD 0.012) mm/y, and the mean polyethylene volumetric wear rate was 3.15 (SD 2.8) mm3/year, with no significant differences based on articulation type or head size. CONCLUSIONS Total hip arthroplasty with HXLPE in patients ≤ 50 years of age continues to demonstrate excellent long-term clinical and radiographic outcomes with low wear characteristics at 20-year follow-up, regardless of femoral head material or size.
Collapse
Affiliation(s)
- Bradford P Zitsch
- Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, Nebraska
| | - Kevin M Cahoy
- College of Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | - Nathanael D Urban
- College of Medicine, University of Nebraska Medical Center, Omaha, Nebraska
| | - Brandt C Buckner
- Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, Nebraska
| | - Kevin L Garvin
- Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, Nebraska
| |
Collapse
|
2
|
Shankar D, Jambagi SC, Gowda N, Lakshmi KS, Jayanthi KJ, Chaudhary VK. Effect of Surface Chemistry on Hemolysis, Thrombogenicity, and Toxicity of Carbon Nanotube Doped Thermally Sprayed Hydroxyapatite Implants. ACS Biomater Sci Eng 2024; 10:1403-1417. [PMID: 38308598 DOI: 10.1021/acsbiomaterials.3c00912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2024]
Abstract
Assessing blood compatibility is crucial before in vivo procedures and is considered more reliable than many in vitro tests. This study examines the physiochemical properties and blood compatibility of bioactive powders ((0.5-2 wt % carbon nanotube (CNT)/alumina)-20 wt %)) produced through a heterocoagulation colloidal technique followed by ball milling with hydroxyapatite (HAp). The 1 wt % CNT composite demonstrated a surface charge ∼5 times higher than HAp at pH 7.4, with a value of -11 mV compared to -2 mV. This increase in electrostatic charge is desirable for achieving hemocompatibility, as evidenced by a range of blood compatibility assessments, including hemolysis, blood clotting, platelet adhesion, platelet activation, and coagulation assays (prothrombin time (PT) and activated partial thrombin time (aPTT)). The 1 wt % CNT composite exhibited hemolysis ranging from 2 to 7%, indicating its hemocompatibility. In the blood clot investigation, the absorbance values for 1-2 wt % CNT samples were 0.927 ± 0.038 and 1.184 ± 0.128, respectively, indicating their nonthrombogenicity. Additionally, the percentage of platelet adhered on the 1 wt % CNT sample (∼5.67%) showed a ∼2.5-fold decrement compared to the clinically used negative control, polypropylene (∼13.73%). The PT and aPTT experiments showed no difference in the coagulation time for CNT samples even at higher concentrations, unlike HAC2 (80 mg). In conclusion, the 1 wt % CNT sample was nontoxic to human blood, making it more hemocompatible, nonhemolytic, and nonthrombogenic than other samples. This reliable study reduces the need for additional in vitro and in vivo studies before clinical trials, saving time and cost.
Collapse
Affiliation(s)
- Deep Shankar
- Surface Engineering Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Srinivasnagar, Surathkal 575025, India
| | - Sudhakar C Jambagi
- Surface Engineering Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Srinivasnagar, Surathkal 575025, India
| | - Niranjan Gowda
- Pathology Lab, Department of Pathology, Sanjay Gandhi Institute of Trauma and Orthopedics, Jayanagar East, Bengaluru 560011, India
| | - K S Lakshmi
- Pathology Lab, Department of Pathology, Sanjay Gandhi Institute of Trauma and Orthopedics, Jayanagar East, Bengaluru 560011, India
| | - K J Jayanthi
- Pathology Lab, Department of Pathology, Sanjay Gandhi Institute of Trauma and Orthopedics, Jayanagar East, Bengaluru 560011, India
| | - Vikash Kumar Chaudhary
- Surface Engineering Laboratory, Department of Mechanical Engineering, National Institute of Technology Karnataka, Srinivasnagar, Surathkal 575025, India
| |
Collapse
|
3
|
Paulsen RT, Revald PH, Kjærsgaard-Andersen P, Timm S, Varnum C. Ceramic-on-Ceramic Total Hip Arthroplasty and Noises: A Prospective Blinded Randomized Controlled Trial of Influence of Component Design. J Arthroplasty 2024; 39:734-738. [PMID: 37652368 DOI: 10.1016/j.arth.2023.08.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 08/22/2023] [Accepted: 08/22/2023] [Indexed: 09/02/2023] Open
Abstract
BACKGROUND Noises have been associated with ceramic-on-ceramic bearings in total hip arthroplasties. The etiology is multifactorial, but a high prevalence of noises was reported in studies using a specific acetabular component system. We examined if specific ceramic component designs are associated with the prevalence of noises in 2 commonly used component systems. We hypothesized that there would be no difference in noises between the 2 systems. METHODS In this randomized controlled trial, 2 different component designs with ceramic bearings were compared. Inclusion criteria were primary total hip arthroplasties, age between 18 and 65 years, and body mass index less than 35. The primary outcome was prevalence of noises, whereas secondary outcomes consisted of European Quality of Life index, visual analog scale, and University of California and Los Angeles activity scale. Follow-up data were collected at 3 and 12 months postoperatively. Data were available for 91 patients in Group 1 and for 92 patients in Group 2. Preoperative patient characteristics were comparable between groups. RESULTS At 12-month follow-up, the prevalence of noises was 19% in Group 1 and 14% in Group 2 (P = .41). European Quality of Life index were 0.89 in Group 1 versus 0.90 in Group 2 (P = .42). The visual analog scale was 81 in both groups (P = .88). When evaluating level of activity, University of California and Los Angeles activity scale scores were 8.2 in both groups (P = .92). CONCLUSION At 12-month follow-up, there was no difference in the prevalence of noises between the 2 component designs.
Collapse
Affiliation(s)
- Rune T Paulsen
- Department of Orthopaedic Surgery, Lillebaelt Hospital, Vejle, Denmark
| | - Peter H Revald
- Department of Orthopaedic Surgery, Lillebaelt Hospital, Vejle, Denmark
| | | | - Signe Timm
- Department of Orthopaedic Surgery, Lillebaelt Hospital, Vejle, Denmark
| | - Claus Varnum
- Department of Orthopaedic Surgery, Lillebaelt Hospital, Vejle, Denmark
| |
Collapse
|
4
|
Poursalehian M, Zafarmandi S, Razzaghof M, Mortazavi SMJ. The impact of retaining the femoral stem in revision total hip arthroplasty: a systematic review, meta-analysis, and meta-regression. Arch Orthop Trauma Surg 2024; 144:947-966. [PMID: 37831198 DOI: 10.1007/s00402-023-05087-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 09/25/2023] [Indexed: 10/14/2023]
Abstract
INTRODUCTION The management of well-fixed femoral stems in revision total hip arthroplasty (rTHA) remains a subject of debate, with concerns over potential complications arising from stem retention. This study aimed to investigate the re-revision rates due to aseptic loosening of the stem, overall re-revision rates, dislocation rates, and factors influencing these outcomes in rTHA with a retained well-fixed femoral stem. MATERIALS AND METHODS A systematic search was conducted across several databases including PubMed, EMBASE, and CENTRAL to identify pertinent publications from their inception through 2023. We specifically focused on studies that reported outcomes of rTHA with retained well-fixed femoral stems. The study designs incorporated in our research encompassed both cohort studies and case series studies. Thirty-five studies involving isolated acetabular revision and retaining the stem were included, representing a total of 3497 patients. Data extraction was tailored to the study questions. Meta-analyses, meta-regression, and subgroup analyses were conducted to evaluate the outcomes and their relationship with various factors. Pooled results, meta-regression, and subgroup analyses were performed using random-effects models. To assess and reduce bias, we employed Egger's test and the trim and fill method. RESULTS The meta-analysis included 3497 patients with a mean follow-up of 9.28 years. The 10-year risk of re-revision after retaining femoral stem using highly cross-linked polyethylene was 1.7% (95% CI 1.1%-2.3%; I2: 60%) for stem aseptic loosening and 8.8% (95% CI 6.2%-11.4%; I2: 78%) overall re-revision. Dislocation risk was 5.7% (95% CI 4.1-7.0%; I2: 61%). Ceramic heads showed lower stem failure risk than metal heads in long-term follow-ups (P < 0.001). The posterolateral approach in revision surgery resulted in better long-term outcomes compared to the direct lateral approach (P < 0.001). Follow-up duration, timeline of study, Harris Hip Score, type of stem fixation, femoral head material, BMI, age, stem age, and surgical approach were evaluated as influential factors on these outcomes. CONCLUSION The re-revision rate due to aseptic loosening of the retained stem during rTHA was found to be significantly low, supporting the idea of retaining well-fixed stems during rTHA. The overall re-revision and dislocation rates also presented comparable or better outcomes to prior studies. A range of factors, including the use of highly cross-linked polyethylene and ceramic femoral heads, was found to influence these outcomes. LEVEL OF EVIDENCE IV. PROSPERO REGISTRATION NUMBER CRD42022351157.
Collapse
Affiliation(s)
- Mohammad Poursalehian
- Orthopedic Surgery Department, Imam Khomeini Hospital Complex, End of Keshavarz Blvd, Tehran, 1419733141, Iran
- Joint Reconstruction Research Center (JRRC), Tehran University of Medical Sciences, Tehran, Iran
| | - Sahar Zafarmandi
- Orthopedic Surgery Department, Imam Khomeini Hospital Complex, End of Keshavarz Blvd, Tehran, 1419733141, Iran
- Joint Reconstruction Research Center (JRRC), Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammadreza Razzaghof
- Orthopedic Surgery Department, Imam Khomeini Hospital Complex, End of Keshavarz Blvd, Tehran, 1419733141, Iran
- Joint Reconstruction Research Center (JRRC), Tehran University of Medical Sciences, Tehran, Iran
| | - Seyed Mohammad Javad Mortazavi
- Orthopedic Surgery Department, Imam Khomeini Hospital Complex, End of Keshavarz Blvd, Tehran, 1419733141, Iran.
- Joint Reconstruction Research Center (JRRC), Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
5
|
Migliorini F, Maffulli N, Pilone M, Bell A, Hildebrand F, Konrads C. Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review. Sci Rep 2023; 13:15612. [PMID: 37730762 PMCID: PMC10511625 DOI: 10.1038/s41598-023-42809-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023] Open
Abstract
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m2), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m2. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano, Teaching Hospital of Paracelsus Medical University (PMU), 39100, Bolzano, Italy.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Stoke on Trent, ST4 7QB, England
- Queen Mary University of London, Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, London, E1 4DG, England
| | - Marco Pilone
- Residency Program in Orthopaedics and Traumatology, University of Milan, 20122, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Christian Konrads
- Department of Orthopaedics and Traumatology, Helios Hanseatic Hospital Stralsund, 18435, Stralsund, Germany
- Medical Faculty, University of Tübingen, 72076, Tübingen, Germany
| |
Collapse
|
6
|
Mirzaali MJ, Moosabeiki V, Rajaai SM, Zhou J, Zadpoor AA. Additive Manufacturing of Biomaterials-Design Principles and Their Implementation. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15155457. [PMID: 35955393 PMCID: PMC9369548 DOI: 10.3390/ma15155457] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/25/2022] [Accepted: 07/28/2022] [Indexed: 05/04/2023]
Abstract
Additive manufacturing (AM, also known as 3D printing) is an advanced manufacturing technique that has enabled progress in the design and fabrication of customised or patient-specific (meta-)biomaterials and biomedical devices (e.g., implants, prosthetics, and orthotics) with complex internal microstructures and tuneable properties. In the past few decades, several design guidelines have been proposed for creating porous lattice structures, particularly for biomedical applications. Meanwhile, the capabilities of AM to fabricate a wide range of biomaterials, including metals and their alloys, polymers, and ceramics, have been exploited, offering unprecedented benefits to medical professionals and patients alike. In this review article, we provide an overview of the design principles that have been developed and used for the AM of biomaterials as well as those dealing with three major categories of biomaterials, i.e., metals (and their alloys), polymers, and ceramics. The design strategies can be categorised as: library-based design, topology optimisation, bio-inspired design, and meta-biomaterials. Recent developments related to the biomedical applications and fabrication methods of AM aimed at enhancing the quality of final 3D-printed biomaterials and improving their physical, mechanical, and biological characteristics are also highlighted. Finally, examples of 3D-printed biomaterials with tuned properties and functionalities are presented.
Collapse
|
7
|
Yakkanti RR, Ocksrider JL, Patel AA, Kolevar MP, Moore RD, Rimnac CM, Kraay MJ, Wright TM, Baral EC, Robinson RP. Unexpected Wear of a Uniquely Designed Moderately Cross-Linked Polyethylene in Total Hip Arthroplasty. J Arthroplasty 2022; 37:1130-1135. [PMID: 35131388 DOI: 10.1016/j.arth.2022.01.093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 01/26/2022] [Accepted: 01/31/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND A uniquely designed, non-heat-treated moderately cross-linked acetabular polyethylene liner used in total hip arthroplasty (THA) demonstrated excessive wear during routine follow-up, prompting an evaluation of the linear wear rate. METHODS All THAs were performed by the senior author. The study group included 38 THAs using the uniquely designed polyethylene in question, compared to a control group of 21 THAs using another moderately cross-linked polyethylene with good 10-year outcomes. Two-dimensional linear head penetration wear measurements were obtained using the Martell Hip Analysis Suite, and retrieval analysis was performed on two liners. RESULTS The study group had a significantly higher average penetration rate of 0.089 mm/y than the control group average rate of 0.047 mm/y (P = .04). Forty-five percent of the study group had a wear rate above the osteolysis threshold (0.1 mm/y), compared to 24% in the control group. Macroscopic analysis of two retrieved liners validated the radiographic findings. CONCLUSION The data suggest unexpectedly higher wear rates for a moderately cross-linked polyethylene design, with nearly half of the study group at risk for osteolysis. Further registry or database analyses of this particular moderately cross-linked polyethylene are warranted.
Collapse
Affiliation(s)
- Ramakanth R Yakkanti
- Department of Orthopaedic Surgery, University of Miami / Jackson Memorial Health System, Miami, FL
| | - Justin L Ocksrider
- Department of Orthopaedic Surgery, University of Miami / Jackson Memorial Health System, Miami, FL
| | - Anand A Patel
- Summit Medical Group of New Jersey, Florham Park, NJ
| | | | | | | | | | | | | | - Raymond P Robinson
- Department of Orthopaedic Surgery, University of Miami / Jackson Memorial Health System, Miami, FL
| |
Collapse
|
8
|
Duensing IM, Stanley S, Bolognesi M. Fracture of a 40-mm BIOLOX Delta Femoral Head. Arthroplast Today 2021; 10:144-148. [PMID: 34401417 PMCID: PMC8353345 DOI: 10.1016/j.artd.2021.06.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 06/23/2021] [Accepted: 06/26/2021] [Indexed: 11/17/2022] Open
Abstract
Ceramic bearing surfaces have gained popularity in total hip arthroplasty as a result of the favorable mechanical properties and low wear rates. Despite the recognition as an attractive articulation, problems such as ceramic head fracture persist. Smaller heads and higher body mass indices are touted as risk factors for ceramic head fracture and are often associated with antecedent trauma. We present a case report of an 83-year-old male with a body mass index of 26.7 kg/m2 who suffered a fracture of a 40-mm ceramic femoral head. This occurred atraumatically 5 years from his index surgery. This patient underwent revision total hip arthroplasty which included debridement of ceramic debris and alteration of the bearing surface with femoral head and polyethylene liner exchange.
Collapse
Affiliation(s)
- Ian M Duensing
- Department of Orthopaedics, Duke University, Durham, NC, USA
| | - Samuel Stanley
- Department of Orthopaedics, Duke University, Durham, NC, USA
| | | |
Collapse
|
9
|
Chung KY, Cheung KW, Fan CH, Poon WC, Chiu KH, Ho KKW. Long-Term Outcome on the Mal-Seating of Ceramic-on-Ceramic Articulation in Total Hip Arthroplasty. J Arthroplasty 2021; 36:2100-2104. [PMID: 33573813 DOI: 10.1016/j.arth.2021.01.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 01/04/2021] [Accepted: 01/11/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Total hip arthroplasty with ceramic-on-ceramic articulation aims to decrease wear, osteolysis, and aseptic loosening. A metal-backed ceramic liner was developed to reduce the risk of liner fracture. However, a significant number of cases of mal-seating of the metal-backed ceramic liner were observed in the 2000s, and there were concerns about their outcome. This review aims to investigate the long-term performance of the mal-seated ceramic liner. METHODS From July 2003 to March 2007, 35 ceramic-on-ceramic total hip arthroplasties were performed with the Trident acetabular system. Clinical assessment, radiological analysis, and outcome assessment were performed. The prevalence of liner mal-seating and its long-term outcomes were investigated. RESULTS There was liner mal-seating in 8 hips (22.9%). One liner was exchanged in the early postoperative period. No revision surgery was required for the remaining 7 hips at a mean follow-up of 14 years. All patients were free of hip pain with a mean Harris Hip Score of 94.7 at the most recent follow-up. No adverse event was observed. CONCLUSION The long-term outcomes of the mal-seated liner were favorable. However, surgeons should exercise meticulous surgical technique to achieve a properly aligned liner within the acetabular shell to minimize this potentially correctable error.
Collapse
Affiliation(s)
| | | | - Chi-Ho Fan
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Tai Po, Hong Kong
| | - Wai-Chin Poon
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Kwok-Hing Chiu
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Shatin, Hong Kong
| | - Kevin Ki-Wai Ho
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
| |
Collapse
|
10
|
Park CH, Kang SG, Bae DK, Song SJ. Mid-term clinical and radiological results do not differ between fixed- and mobile-bearing total knee arthroplasty using titanium-nitride-coated posterior-stabilized prostheses: a prospective randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 2019; 27:1165-1173. [PMID: 30088030 DOI: 10.1007/s00167-018-5095-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Accepted: 08/03/2018] [Indexed: 01/31/2023]
Abstract
PURPOSE This study was performed to prospectively compare the clinical and radiographic results between mobile-bearing (MB) and fixed-bearing (FB) TKAs using ceramic titanium nitride (TiN)-coated prostheses. METHODS Seventy MB and 70 FB TKAs using TiN-coated prostheses (ACS®) were prospectively evaluated. There were no differences in demographic characteristics between the two groups. Clinically, the Knee Society knee and function scores, WOMAC, and range of motion (ROM) were compared. Considering the possibility of a kinematic change in the polyethylene (PE) insert and a decrease in ROM following MB TKA, serial changes in the ROM were also compared. The thickness of the PE insert was compared according to the size of the femoral component. Radiographically, the alignment and positions of the components were compared. RESULTS There were no differences between the two groups in clinical scores or ROM (n.s.). The maximum flexion increased from 133.5° ± 8.3° to 137.6° ± 5.5° across all time points in the MB group. The serial maximum flexion angles did not differ between the two groups over time (n.s.). The average thickness of the PE insert was greater in the MB group (12.0 ± 1.9 vs. 11.2 ± 1.6 mm, respectively, p = 0.008), especially when a large femoral component was used (12.7 ± 1.9 vs. 11.0 ± 1.5 mm, p = 0.005). The pre- and postoperative mechanical axes and positions of the components did not differ between the two groups (n.s.). CONCLUSIONS TiN-coated MB TKA showed no significant advantage over FB TKA. The selection of bearing design would be clinically insignificant when using the TiN-coated TKA prosthesis. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Cheol Hee Park
- Department of Medicine, Graduate School, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Se Gu Kang
- Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Dae Kyung Bae
- Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea
| | - Sang Jun Song
- Department of Medicine, Graduate School, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea. .,Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 24 Kyunghee-daero, Dongdaemun-gu, Seoul, 02453, South Korea.
| |
Collapse
|
11
|
Abstract
INTRODUCTION We have investigated the revision rates of all bearing surface combinations for primary total hip replacement (THR) registered on the New Zealand Joint Registry (NZJR) to determine which coupling has been the most durable and successful over the last 16 years. METHODS There were 106,139 primary THRs registered, resulting in 4,960 revisions for any cause. We examined all-cause revision rates, reasons for revision and performed survival analyses. RESULTS Ceramic-on-highly cross-linked polyethylene (CoPx) had the lowest all-cause revision rate of 0.54/100-component-years (cys) (95% confidence interval 0.48 to 0.61). This was superior to all other hard-on-soft bearing combinations in unadjusted analysis. Furthermore, the age of patients receiving CoPx was significantly lower than for metal-on-polyethylene (mean 62.9; standard deviation [SD] 10.1 vs. 69.1; SD 9.6; p<0.001). Acetabular loosening was the reason for revision in 14.5% of CoPx, compared to 33% of MoP THRs (p<0.001). Metal-on-metal bearings had the highest revision rate of 1.43/100 cys and were significantly inferior to CoPx (p<0.001). Kaplan-Meier analysis and Cox regression analyses were performed and we adjusted the analyses to control for age, femoral head size, surgical approach and fixation. CONCLUSIONS CoPx remained the most durable and successful coupling used in primary THR in New Zealand irrespective of age, gender or size of femoral head.
Collapse
|
12
|
Abstract
Metal-on-highly cross-linked polyethylene is considered the preferred bearing surface for conventional total hip arthroplasty because of its safety profile and excellent results in the first 10 to 15 years of use. However, with younger patient age, activity expectations increase, and the life expectancy of patients with total hip arthroplasty also has increased, so interest remains in other bearing couples. These other options include the use of various ceramic composites for the femoral head on highly cross-linked polyethylene, the so-called second-generation antioxidant polyethylenes, and ceramic acetabular liners. Several of these bearing couples have shown excellent wear rates in vitro, and short-term clinical studies have demonstrated favorable wear and safety results. It is uncertain whether any of these bearing couples should be adopted at present. Understanding the unique properties and possible complications of these bearing couples is critical for appropriate implant selection.
Collapse
|
13
|
Combined Vascular and Orthopaedic Approach for a Pseudotumor Causing Deep Vein Thrombosis after Metal-on-Metal Hip Resurfacing Arthroplasty. Case Rep Orthop 2015; 2015:926263. [PMID: 26457216 PMCID: PMC4592736 DOI: 10.1155/2015/926263] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2015] [Accepted: 08/24/2015] [Indexed: 12/12/2022] Open
Abstract
Introduction. Metal-on-metal (MoM) hip resurfacings have been associated with a variety of complications resulting from adverse reaction to metal debris. Pseudotumors have rarely been reported to cause deep venous thrombosis (DVT). Study Design. A case report and a review of the literature. Case Presentation. A 75-year-old female who had left metal-on-metal hip resurfacing 6 years ago presented with left groin pain associated with unilateral lower limb edema and swelling. By duplex and MRI studies, our patient had an extensive soft tissue necrosis associated with a large pelvic mass causing extensive DVT of the lower limb secondary to mechanical compression of the left iliac vein. Results. Our case was initially treated for DVT followed by dual surgical approach. The pseudotumor was excised through a separate iliofemoral approach and revision of the hip implant was undertaken through a posterior approach in the same setting. An inferior vena cava (IVC) filter was inserted to minimise the perioperative risks of handling the iliac veins. Conclusion. A combined approach with vascular surgeons is required. Combined resection of the pseudotumor and revision of the metal bearing surfaces is essential, in order to achieve a good surgical outcome in this rare complication.
Collapse
|
14
|
Liu A, Richards L, Bladen CL, Ingham E, Fisher J, Tipper JL. The biological response to nanometre-sized polymer particles. Acta Biomater 2015; 23:38-51. [PMID: 26004221 PMCID: PMC4535318 DOI: 10.1016/j.actbio.2015.05.016] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2015] [Revised: 05/08/2015] [Accepted: 05/15/2015] [Indexed: 11/01/2022]
Abstract
Recently, nanometre-sized UHMWPE particles generated from hip and knee replacements have been identified in vitro and in vivo. UHMWPE particles in the 0.1-1.0μm size range have been shown to be more biologically active than larger particles, provoking an inflammatory response implicated in late aseptic loosening of total joint replacements. The biological activity of nanometre-sized particles has not previously been studied. The biological response to clinically-relevant UHMWPE wear particles including nanometre-sized and micrometre-sized, along with polystyrene particles (FluoSpheres 20nm, 60nm, 200nm and 1.0μm), and nanometre-sized model polyethylene particles (Ceridust 3615®), was determined in terms of osteolytic cytokine release from primary human peripheral blood mononuclear cells (PBMNCs). Nanometre-sized UHMWPE wear particles, nanometre-sized Ceridust 3615® and 20nm FluoSpheres had no significant effect on TNF-α, IL-1β, IL-6 and IL-8 release from PBMNCs at a concentration of 100μm(3) particles per cell after 12 and 24h. The micrometre-size UHMWPE wear particles (0.1-1.0μm) and 60nm, 200nm and 1.0μm FluoSpheres caused significantly elevated osteolytic cytokine release from PBMNCs. These results indicated that particles below circa 50nm fail to activate PBMNCs and that particle size, composition and morphology played a crucial role in cytokine release by particle stimulated macrophages.
Collapse
|
15
|
Chen Z, Wang Z, Wang Q, Cui W, Liu F, Fan W. Changes in early serum metal ion levels and impact on liver, kidney, and immune markers following metal-on-metal total hip arthroplasty. J Arthroplasty 2014; 29:612-6. [PMID: 23993737 DOI: 10.1016/j.arth.2013.07.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2013] [Revised: 07/22/2013] [Accepted: 07/24/2013] [Indexed: 02/01/2023] Open
Abstract
We retrospectively studied 32 consecutive patients (32 hips) who underwent THA with a Durom large-head, MOM articulation between January 2008 and December 2010. Of the patients who underwent THA using a Trilogy metal on polyethylene prosthesis during the same period, 32 were chosen to form the Trilogy group. 32 volunteers were chosen to form the control group. At the last follow-up, serum metal ion levels, liver and kidney function and host immunologic immune responses were evaluated. The mean Co and Cr levels in the Durom group were 4.33- and 1.95-fold higher than those in the Trilogy group. CD3+, CD4+ and CD8+ cell levels in the Durom group were significantly decreased. The INF-γ level in the Durom group was significantly higher than that in the Trilogy and control groups.
Collapse
Affiliation(s)
- Zhefeng Chen
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Zhen Wang
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Qing Wang
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Weiding Cui
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Feng Liu
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| | - Weimin Fan
- Department of Orthopedics, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China
| |
Collapse
|
16
|
Abstract
This article is a comprehensive review of the published literature on total hip replacement design. It seeks to provide a nonbiased view of the technology related to total hip implants and bearing surfaces. Implant designs and fixation methods are discussed with summaries of their respective long-term outcome studies. Fixation methods include cemented, cementless and hybrid techniques and are explained and presented with current outcome data and their respective failure modes that have promoted new technological development. The current data point toward cementless acetabular fixation as being superior to cemented fixation. As for stem fixation, there are good data to suggest that either method of fixation is acceptable in the proper setting. Also included in this article is a brief review of bearing surfaces and hip biomechanics.
Collapse
Affiliation(s)
- James A Sanfilippo
- Thomas Jefferson University Hospital, Resident in Orthopedic Surgery, Department of Orthopedic Surgery, Philadelphia, PA 19107, USA.
| | | |
Collapse
|
17
|
Mantripragada VP, Lecka-Czernik B, Ebraheim NA, Jayasuriya AC. An overview of recent advances in designing orthopedic and craniofacial implants. J Biomed Mater Res A 2013; 101:3349-64. [PMID: 23766134 PMCID: PMC4854641 DOI: 10.1002/jbm.a.34605] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Revised: 01/11/2013] [Accepted: 01/11/2013] [Indexed: 01/22/2023]
Abstract
Great deal of research is still going on in the field of orthopedic and craniofacial implant development to resolve various issues being faced by the industry today. Despite several disadvantages of the metallic implants, they continue to be used, primarily because of their superior mechanical properties. In order to minimize the harmful effects of the metallic implants and its by-products, several modifications are being made to these materials, for instance nickel-free stainless steel, cobalt-chromium and titanium alloys are being introduced to eliminate the toxic effects of nickel being released from the alloys, introduce metallic implants with lower modulus, reduce the cost of these alloys by replacing rare elements with less expensive elements etc. New alloys like tantalum, niobium, zirconium, and magnesium are receiving attention given their satisfying mechanical and biological properties. Non-oxide ceramics like silicon nitride and silicon carbide are being currently developed as a promising implant material possessing a combination of properties such as good wear and corrosion resistance, increased ductility, good fracture and creep resistance, and relatively high hardness in comparison to alumina. Polymer/magnesium composites are being developed to improve mechanical properties as well as retain polymer's property of degradation. Recent advances in orthobiologics are proving interesting as well. This paper thus deals with the latest improvements being made to the existing implant materials and includes new materials being introduced in the field of biomaterials.
Collapse
|
18
|
Gremillard L, Martin L, Zych L, Crosnier E, Chevalier J, Charbouillot A, Sainsot P, Espinouse J, Aurelle JL. Combining ageing and wear to assess the durability of zirconia-based ceramic heads for total hip arthroplasty. Acta Biomater 2013; 9:7545-55. [PMID: 23541600 DOI: 10.1016/j.actbio.2013.03.030] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2012] [Revised: 02/13/2013] [Accepted: 03/20/2013] [Indexed: 02/04/2023]
Abstract
The degradation of zirconia-based ceramic components for total hip arthroplasty (head and cup) has been the topic of many works. However, the correlation between what is measured in vivo and what is expected from in vitro simulations on hip simulators may be sometimes feeble, especially where zirconia component are concerned, mainly due to a lack of representativeness of in vitro experiments. The present study seeks to explore the combined effects of hydrothermal ageing and wear on zirconia components. It shows that hydrothermal ageing increases the roughness of zirconia components, which in turn might increase the wear rate of the polyethylene counterparts. Moreover, the friction during hip simulation increases the ageing rate of the zirconia components. This auto-accelerating degradation may explain some of the poor long-term in vivo results of zirconia hip prostheses reported in the literature. Finally, it is shown that zirconia-toughened alumina components may be free from this combined degradation.
Collapse
|
19
|
Memon AR, Galbraith JG, Harty JA, Gul R. Inflammatory pseudotumor causing deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty. J Arthroplasty 2013; 28:197.e9-12. [PMID: 22503335 DOI: 10.1016/j.arth.2012.02.014] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2011] [Revised: 12/18/2011] [Accepted: 02/09/2012] [Indexed: 02/01/2023] Open
Abstract
Metal-on-metal hip resurfacings have recently been associated with a variety of complications resulting from adverse reaction to metal debris. We report a case of extensive soft tissue necrosis associated with a huge pelvic mass causing extensive deep vein thrombosis of the lower limb secondary to mechanical compression of the iliac vein. This is a rare and unusual cause of deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty.
Collapse
Affiliation(s)
- Adeel Rasool Memon
- Department of Trauma and Orthopaedics, Cork University Hospital, Cork, Ireland
| | | | | | | |
Collapse
|
20
|
Metal-on-metal bearings, inflammatory pseudotumours and their neurological manifestations. Hip Int 2012; 22:129-36. [PMID: 22476931 DOI: 10.5301/hip.2012.9185] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/17/2012] [Indexed: 02/04/2023]
Abstract
Metal-on-metal bearings have become more popular for hip arthroplasty in younger patients in the last 15 years. We present a review of the neurological consequences relating to such bearing surfaces illustrated by an appropriate case report. The mechanisms of increased metal ion production and pseudotumour formation are discussed. If unexplained neurology, hip/groin pain or a localised mass around the hip are present with a metal bearing hip then urgent referral to a specialist orthopaedic surgeon is warranted for consideration of exchange arthroplasty.
Collapse
|
21
|
|
22
|
Billi F, Benya P, Kavanaugh A, Adams J, McKellop H, Ebramzadeh E. The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles. Clin Orthop Relat Res 2012; 470:339-50. [PMID: 21932105 PMCID: PMC3254749 DOI: 10.1007/s11999-011-2058-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Metal-on-metal and ceramic-on-ceramic bearings were introduced as alternatives to conventional polyethylene in hip arthroplasties to reduce wear. Characterization of wear particles has been particularly challenging due to the low amount and small size of wear particles. Current methods of analysis of such particles have shortcomings, including particle loss, clumping, and inaccurate morphologic and chemical characterization. QUESTIONS/PURPOSES We describe a method to recover and characterize metal and ceramic particles that (1) improves particle purification, separation, and display; (2) allows for precise particle shape characterization; (3) allows accurate chemical identification; and (4) minimizes particle loss. METHODS After enzymatic digestion, a single pass of ultracentrifugation cleaned and deposited particles onto silicon wafers or grids for imaging analysis. During centrifugation, particles were passed through multiple layers of denaturants and a metal-selective high-density layer that minimized protein and nucleic acid contamination. The protocol prevented aggregation, providing well-dispersed particles for chemical and morphologic analysis. We evaluated the efficacy and accuracy of this protocol by recovering gold nanobeads and metal and ceramic particles from joint simulator wear tests. RESULTS The new protocol recovered particles ranging in size from nanometers to micrometers and enabled accurate morphologic and chemical characterization of individual particles. CONCLUSION Both polyethylene and metal wear debris can be simultaneously analyzed from the same sample by combining a silicon wafer display protocol for polyethylene and the metal and ceramics silicon wafer display protocol. CLINICAL RELEVANCE Accurate analysis of wear debris is essential in understanding the processes that produce debris and a key step in development of more durable and biocompatible implants.
Collapse
Affiliation(s)
- Fabrizio Billi
- Department of Orthopaedic Surgery, The J. Vernon Luck Sr., MD, Orthopaedic Research Center at Orthopaedic Hospital, UCLA/Orthopaedic Hospital, David Geffen School of Medicine, Los Angeles, CA 90007, USA.
| | | | | | | | | | | |
Collapse
|
23
|
A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian academic centers. J Bone Joint Surg Am 2011; 93 Suppl 2:118-21. [PMID: 21543700 DOI: 10.2106/jbjs.j.01848] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Metal-on-metal bearings for hip arthroplasty have been in clinical use for over twenty years with excellent clinical results reported worldwide. A small percentage (<1%) of patients have developed an inflammatory response, and a more severe inflammatory response termed pseudotumor has been more recently reported. The primary purpose of this study was to determine the prevalence of pseudotumor following metal-on-metal hip resurfacing in Canadian academic centers. METHODS Nine of the fourteen centers that perform metal-on-metal hip resurfacings were surveyed. The number of metal-on-metal hip resurfacing arthroplasties performed at each center was determined, as was the number of patients who presented with a pseudotumor and subsequently required revision hip surgery between 2002 and December 2008. RESULTS At the nine centers, 3432 hip resurfacing arthroplasties were performed; 76.9% of the patients were male, the mean age was 51.2 years (range, sixteen to eighty-three years), and the mean body-mass index was 28.1 (range, 17 to 55). The mean length of follow-up was 3.4 years (range, two to nine years). A pseudotumor developed after four of the 3432 arthroplasties, for a prevalence of 0.10%. CONCLUSIONS Although pseudotumors remain a concern after metal-on-metal hip resurfacing, the prevalence at short to midterm follow-up is very low in this multicenter survey. Continued close monitoring is required to determine what clinical factors are involved with the uncommon pseudotumor formation.
Collapse
Affiliation(s)
-
- Division of Orthopaedic Surgery, University of Ottawa, Ottawa, 501 Smyth Road, CCW 1646, Box 502, Ottawa, ON K1H 8L6, Canada
| |
Collapse
|
24
|
Beaulé PE, Kim PR, Hamdi A, Fazekas A. A prospective metal ion study of large-head metal-on-metal bearing: a matched-pair analysis of hip resurfacing versus total hip replacement. Orthop Clin North Am 2011; 42:251-7, ix. [PMID: 21435499 DOI: 10.1016/j.ocl.2011.01.005] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The current study measured ion release among large-head metal-on-metal hip bearings. Twenty-six patients with a modular, Profemur® TL with A-Class® big femoral head total hip replacement were matched (gender, femoral size, BMI) with a group of 26 patients with the Conserve® Plus implant hip resurfacing. Compared with HR patients, THR patients had higher median serum cobalt ion levels at 6 months (3.26 vs 1.12 μg/L, P = .002) 1 year (4.51 vs 1.02, P = .002), and 2 years (3.77 vs 1.22, P<.001) following surgery. No differences in chromium ions were observed. Further research is required to determine the clinical significance of elevated serum cobalt ions.
Collapse
Affiliation(s)
- Paul E Beaulé
- The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada.
| | | | | | | |
Collapse
|
25
|
Curry JT, Alexander R, Walker C, Goksel T. Discectomy as the primary surgical option for internal derangement of the temporomandibular joint. J Oral Maxillofac Surg 2010; 69:312. [PMID: 21163384 DOI: 10.1016/j.joms.2010.04.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2010] [Accepted: 04/23/2010] [Indexed: 10/18/2022]
|
26
|
Hacking SA, Pauyo T, Lim L, Legoux JG, Bureau MN. Tissue response to the components of a hydroxyapatite-coated composite femoral implant. J Biomed Mater Res A 2010; 94:953-60. [PMID: 20730932 DOI: 10.1002/jbm.a.32758] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Bone loss around femoral implants used for THA is a persistent clinical concern. It may be caused by stress shielding, generally attributed to a mismatch in stiffness between the implants and host bone. In this regard, a fatigue resistant, carbon fiber (CF) composite femoral implant with bone-matching stiffness has been developed. This study evaluated the tissue response to the three material components of this implant in normal and textured (blasted with 24 grit alumina) surfaces: the hydroxyapatite (HA) coating, the CF composite and the intermediate crystalline HA particulate composite layer to bond to the HA coating (blended). Sprague-Dawley rats underwent bilateral femoral implantation each receiving two rod-like implants. Bone apposition to the HA (37%) and textured Ti (41%) implants was not significantly different. Bone apposition to the untextured CF (14%) and blended (19%) implants and polished Ti (8%) implants was significantly lower. Bone apposition to the textured CF (9%) and blended (11%) implants was lower (but not statistically from the as received or untextured counterparts). Nearly all sections from femurs containing CF implants presented CF debris. There was no evidence of localized bone loss or any strong immune response associated with any of the implant materials. All materials were well tolerated with minimal inflammation despite the presence of particulate debris. The high degree of bone apposition to the HA-coated composite implants and the lack of short-term inflammation and adverse tissue response to the three material implant component support continued evaluation of this composite technology for use in THA.
Collapse
Affiliation(s)
- S A Hacking
- Division of Orthopaedics, Department of Surgery, McGill University Health Center, Montreal, Québec, Canada
| | | | | | | | | |
Collapse
|
27
|
Re: Metal on metal: is it worth the risk? J Arthroplasty 2010; 25:662-4; author reply 664-5. [PMID: 20497851 DOI: 10.1016/j.arth.2010.03.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2010] [Accepted: 03/26/2010] [Indexed: 02/01/2023] Open
|
28
|
Visuri T, Borg H, Pulkkinen P, Paavolainen P, Pukkala E. A retrospective comparative study of mortality and causes of death among patients with metal-on-metal and metal-on-polyethylene total hip prostheses in primary osteoarthritis after a long-term follow-up. BMC Musculoskelet Disord 2010; 11:78. [PMID: 20416065 PMCID: PMC2874765 DOI: 10.1186/1471-2474-11-78] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2009] [Accepted: 04/23/2010] [Indexed: 11/13/2022] Open
Abstract
Background All patients with total hip arthroplasty (THA), especially those with metal-on-metal (MM) THA, are exposed to metallic particles and ions, which may cause total or site-specific mortality. We analyzed the causes of total and site-specific mortality among a cohort of patients with MM and with metal-on-polyethylene (MP) THA after a long follow-up time. Methods Standardized mortality ratios (SMR) of total and site-specific causes of death were calculated for 579 patients with MM (McKee-Farrar) and 1585 patients with MP (Brunswik, Lubinus) THA for primary osteoarthritis. Results Mean follow-up time was 17.9 years for patients with MM and 16.7 years for patients with MP. Overall SMR was 0.95 for the MM cohort and 0.90 for the MP cohort, as compared to the normal population. Both cohorts showed significantly decreased mortality for the first decade postoperatively, equal mortality over the next 10 years, and significantly increased mortality after 20 years. Patients with MM THA had higher cancer mortality (SMR 1.01) than those with MP THA (SMR 0.66) during the first 20 years postoperatively, but not thereafter. Conclusion Both MM and MP prostheses are safe based on total and site-specific mortality of recipients during the first 20 postoperative years in comparison with the general population.
Collapse
Affiliation(s)
- Tuomo Visuri
- Research Institute of Military Medicine, Helsinki, Finland.
| | | | | | | | | |
Collapse
|
29
|
|
30
|
Dahlstrand H, Stark A, Anissian L, Hailer NP. Elevated serum concentrations of cobalt, chromium, nickel, and manganese after metal-on-metal alloarthroplasty of the hip: a prospective randomized study. J Arthroplasty 2009; 24:837-45. [PMID: 18823744 DOI: 10.1016/j.arth.2008.07.019] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2007] [Revised: 05/17/2008] [Accepted: 07/29/2008] [Indexed: 02/01/2023] Open
Abstract
In this prospective randomized study, we investigate metal ion concentrations and clinical outcome 2 years after metal-on-metal (28 patients) or metal-on-polyethylene (26 patients) hip arthroplasty with 28-mm modular heads. Metal ion concentrations in patient serum were analyzed by high-resolution plasma mass spectrometry. The clinical outcome was almost identical in both groups with respect to the Harris hip score and the Medical Outcome Study Short Form-36; and on plain radiography, no signs of loosening occurred in any group. In the metal-on-metal group, concentrations of all investigated ions increased significantly when compared with preoperative values: cobalt, 15.3-fold (95% confidence interval [CI], 9.4-21.2); chromium, 5.2-fold (CI, 3.5-7.0); nickel, 2.1-fold (CI, 1.2-3.0); and manganese, 1.6-fold (CI, 1.3-2.0). In the metal-on-polyethylene group, a smaller but significant increase in the concentrations of cobalt and nickel occurred, whereas concentrations of the other ions did not change significantly.
Collapse
Affiliation(s)
- Henrik Dahlstrand
- Department of Molecular Medicine and Surgery, Section of Orthopaedics, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden
| | | | | | | |
Collapse
|
31
|
Beksaç B, Salas A, González Della Valle A, Salvati EA. Wear is reduced in THA performed with highly cross-linked polyethylene. Clin Orthop Relat Res 2009; 467:1765-72. [PMID: 19082863 PMCID: PMC2690743 DOI: 10.1007/s11999-008-0661-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2008] [Accepted: 11/24/2008] [Indexed: 01/31/2023]
Abstract
UNLABELLED Highly cross-linked polyethylene (HCLPE) has been used extensively to decrease osteolysis and related implant failure in THA. We compared the wear rate of HCLPE and noncross-linked conventional PE (CPE) liners and the rate of radiographic calcar resorption and osteolysis in young patients (35-60 years of age) who underwent THA by one surgeon. Thirty-four patients (41 THAs) who received a hybrid THA using a HCLPE liner were match-paired for age, gender, body mass index, and diagnosis with a group of patients who underwent THA with identical implants but with a CPE liner. The minimum followup was 4 years (average, 5.3; range, 4-8 years). Using the Livermore measurement technique, the averages of total wear of the HCLPE and CPE liners were 0.01 mm (range, -0.23-0.4) and 0.64 mm (range, 0-1.7), respectively. The average annual wear was less for the HCLPE than the noncross-linked PE (0.002 mm, range, -0.05-0.1 versus 0.12 mm, range, 0-0.29, respectively). Four hips in the HCLPE group and 23 in the CPE group had calcar resorption measuring averages of 2.5 mm (range, 2-3) and 7.5 mm (range, 1.8-23.8), respectively. Periprosthetic osteolysis occurred in two and eight hips in the HCLPE and CPE groups, respectively. Longer followup is needed to determine if these findings will result in improved implant survivorship. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Burak Beksaç
- Department of Orthopedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA ,Department of Orthopedic Surgery, Weill Medical College of Cornell University, New York, NY USA
| | - Antonio Salas
- Department of Orthopedic Surgery, Hospital de Ortopedia y Traumatologia 21, Monterrey, Mexico
| | - Alejandro González Della Valle
- Department of Orthopedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA ,Department of Orthopedic Surgery, Weill Medical College of Cornell University, New York, NY USA
| | - Eduardo A. Salvati
- Department of Orthopedic Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA ,Department of Orthopedic Surgery, Weill Medical College of Cornell University, New York, NY USA
| |
Collapse
|
32
|
Braunstein V, Sprecher CM, Wimmer MA, Milz S, Taeger G. Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop 2009; 80:283-90. [PMID: 19421914 PMCID: PMC2823209 DOI: 10.3109/17453670902988394] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Particles originating from the articulating surfaces of hip endoprostheses often induce an inflammatory response, which can be related to implant failure. We therefore analyzed the metal content in capsular tissue from 44 McKee-Farrar metal-on-metal hip prostheses (with 3 different head sizes) and we also analyzed the morphological structure of layers located on articulating surfaces. METHODS Atomic absorption spectrometry (AAS) was used to analyze the metal content in capsular tissue. Visually detectable carbon layers located on the articulating surfaces were evaluated using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS). RESULTS Metallic debris was detected in all capsular tissue samples but no statistically significant differences in metal content were found in relation to implant head size. The morphological characteristics of the different layer zones allowed an exact analysis of contact and non-contact areas. Furthermore, surface layers appear to have a protective function because they can prevent sharp-edged particles from damaging the prostheses surface. INTERPRETATION The implant head size does not appear to influence the amount of metallic debris. The layers obviously act like a lubricating agent because the protection function does not occur in regions without layers where the metal surface often shows numerous scratches. As layers are not generated immediately after the implantation of hip prostheses, these findings may at least partially explain the high amount of wear early after implantation.
Collapse
Affiliation(s)
| | | | - Markus A Wimmer
- Department of Orthopedic Surgery, Rush University Medical CenterChicago, ILUSA
| | - Stefan Milz
- AO Research Institute, AO FoundationDavosSwitzerland
| | - Georg Taeger
- Department of Trauma Surgery, University HospitalEssenGermany
| |
Collapse
|
33
|
A double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty. J Arthroplasty 2009; 24:505-10. [PMID: 18547784 DOI: 10.1016/j.arth.2008.02.011] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2007] [Accepted: 02/10/2008] [Indexed: 02/01/2023] Open
Abstract
Highly cross-linked polyethylene was developed to reduce articular bearing wear in total hip arthroplasty. In vitro studies have shown reduced wear in comparison with conventional polyethylene. A double-blind, prospective, randomized trial was performed comparing highly cross-linked and conventional polyethylene in 119 patients. The primary outcome variables were linear, 3-dimensional, and volumetric wear as determined by analysis of digitized radiographs using validated wear measurement software. Linear, 3-dimensional, and volumetric wear rates were significantly less in the highly cross-linked polyethylene group between 6 months and 4 years postoperatively (P < .05). The data presented here show that highly cross-linked polyethylene reduces short-term polyethylene wear. The intermediate and long-term clinical results of highly cross-linked polyethylene remain unknown pending further follow-up.
Collapse
|
34
|
Savarino L, Baldini N, Ciapetti G, Pellacani A, Giunti A. Is wear debris responsible for failure in alumina-on-alumina implants? Acta Orthop 2009; 80:162-7. [PMID: 19404796 PMCID: PMC2823169 DOI: 10.3109/17453670902876730] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2008] [Accepted: 10/14/2008] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Ceramic-on-ceramic articulation is an attractive alternative to metal-on-polyethylene (PE) bearings, but little is known about the in vivo effects induced by dissemination of alumina wear debris in the periprosthetic tissues. We hypothesized that wear debris is not the main factor responsible for loosening and failure of the implant but that mechanical problems caused by incorrect surgical technique, prosthetic design, or trauma, may cause instability of the implants and result in production of wear debris. PATIENTS AND METHODS Clinical, radiographic, laboratory, and microbiological data from 30 consecutive patients with failed alumina-on-alumina arthroplasties, 19 with screwed socket and 11 with press-fit socket, were systematically collected and evaluated. Retrieved peri-implant tissues and prosthesis wear were also analyzed. RESULTS AND INTERPRETATION Loosening was due to malpositioning, primary mechanical instability, trauma, or infection. Bone stock was generally preserved, even if screwed implants showed higher levels of osteolysis. Variable implant wear and tissue macrophage reaction were present but activation of giant cells/osteoclasts was not induced, and no correlation between histocytic reaction and the level of osteolysis was found. These findings indicate that, in contrast to the situation with metal-on-PE bearings, wear debris and occasional osteolysis were the effect rather than the cause of failure of ceramic-on-ceramic implants, and that press-fit socket fixation was the socket fixation design of preference.
Collapse
Affiliation(s)
- Lucia Savarino
- Laboratory for Pathophysiology of Orthopaedic Implant, Bologna, Italy.
| | | | | | | | | |
Collapse
|
35
|
Abstract
Metal-on-metal bearing couples remain a popular option in total hip arthroplasty and are the only currently available option for surface replacement arthroplasty. In general, the intermediate-term clinical performance of metal-on-metal bearings has been favorable. There are, however, lingering concerns about the biologic consequences of metal release from these bearings in terms of both local tissue effects, including delayed-type hypersensitivity reactions in a subset of patients, and potential systemic effects as a consequence of chronic elevations in serum cobalt and chromium content. Advances in the understanding of the operant wear mechanisms in these bearings provide strategies for reducing the burden of metal released into the periprosthetic milieu, which in turn will mitigate the concerns about the biologic response to the metal debris. Continued surveillance of patients with these bearings is warranted to determine whether metal-on-metal bearing couples provide a long-term survivorship advantage over other bearing couple options and to evaluate whether chronic elevations in the body burden of cobalt and chromium is well tolerated over the long term.
Collapse
|
36
|
Illgen RL, Bauer LM, Hotujec BT, Kolpin SE, Bakhtiar A, Forsythe TM. Highly crosslinked vs conventional polyethylene particles: relative in vivo inflammatory response. J Arthroplasty 2009; 24:117-24. [PMID: 18534436 DOI: 10.1016/j.arth.2008.01.134] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2007] [Accepted: 01/06/2008] [Indexed: 02/08/2023] Open
Abstract
Crosslinked polyethylenes have been introduced to reduce wear and osteolysis. The osteolysis rate depends on many factors including the biologic activity of the wear particles. This study examines the relative inflammatory potential of highly crosslinked and non-crosslinked polyethylene particles. Polyethylene particles were crosslinked and characterized. Dose-response curves were generated for endotoxin-positive and endotoxin-negative particles at each degree of cross-linking using an in vivo model. The 10-MRad crosslinked polyethylene was more inflammatory than an identical dose (25 mg/mL) of non-crosslinked polyethylene (P = .05). Endotoxin increased the inflammatory response to crosslinked and non-crosslinked polyethylene in a similar fashion. These data suggest that the improved wear characteristics of highly crosslinked polyethylenes may be offset somewhat by the modestly increased inflammatory profile of the highly crosslinked compared with non-crosslinked particles.
Collapse
Affiliation(s)
- Richard Lynn Illgen
- Department of Orthopedics and Rehabilitation, University of Wisconsin, Clinical Science Center, Madison, Wisconsin, USA
| | | | | | | | | | | |
Collapse
|
37
|
Drees P, Eckardt A, Gay RE, Gay S, Huber LC. [Molecular pathways in aseptic loosening of orthopaedic endoprosthesis]. ACTA ACUST UNITED AC 2008; 53:93-103. [PMID: 18601617 DOI: 10.1515/bmt.2008.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Operative joint replacement to treat disabling joint conditions secondary to degenerative and inflammatory arthritides has become one of the most efficacious and cost-effective procedures to relieve pain and restore joint function. However, prosthetic implants are not built to last forever and osteolysis and aseptic loosening has been associated with prosthetic arthroplasties since their introduction. The functional life of a synthetic joint is influenced by many factors including the material of the implant, operation procedures and the surgeon involved, as well as patient-related factors. Although promising developments have been achieved in this field, more than 10% of all implants still have to undergo operative revision within 15 years after the initial operation. Failure due to sepsis, fractures and dislocations has become rare; premature loosening of implants on the other hand is becoming much more important. Prosthetic loosening without concurrent infection or trauma is called aseptic loosening. It is generally accepted that small particles ("wear debris") and activated macrophages play a key role in aseptic loosening. The pathophysiology of this condition, however, is still not very well characterized. In this article, we review the molecular mechanisms and signal pathways that were unravelled as responsible factors for loosening orthopaedic implants. Finally, we discuss possible novel strategies for future therapeutic approaches.
Collapse
Affiliation(s)
- Philipp Drees
- Orthopädische Klinik und Poliklinik der Johannes-Gutenberg-Universität, Mainz, Deutschland.
| | | | | | | | | |
Collapse
|
38
|
Highly crosslinked vs conventional polyethylene particles--an in vitro comparison of biologic activities. J Arthroplasty 2008; 23:721-31. [PMID: 18534392 DOI: 10.1016/j.arth.2007.05.043] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2006] [Accepted: 05/28/2007] [Indexed: 02/06/2023] Open
Abstract
Highly cross-linked polyethylenes (HXPEs) have been introduced to reduce wear after hip arthroplasty. The improved wear characteristics of HXPEs are well documented, but the relative biologic activity of HXPE and conventional polyethylene (CPE) particles remains unclear. Longevity (Zimmer, Warsaw, Ind; HXPE) and GUR 1050 (Zimmer; CPE) particles were isolated and characterized from a hip simulator and their in vitro inflammatory responses (tissue necrosis factor *, interleukin 1*, and vascular endothelial growth factor levels) were compared using macrophages. The average diameter of Longevity particles (0.111 microm) was smaller than CPE particles (0.196 microm), and both were predominantly round (granular appearance). The inflammatory response to HXPE and CPE was concentration-dependent. No statistically significant differences were noted at low (0.1 surface area ratio [SAR]) and intermediate (0.75 SAR) doses. At the highest dose tested (2.5 SAR), HXPE was significantly more inflammatory than CPE based on relative tissue necrosis factor alpha and vascular endothelial growth factor secretion levels. Further study is needed to determine if similar findings would be noted in vivo over a broad concentration range.
Collapse
|
39
|
Bitsch RG, Loidolt T, Heisel C, Ball S, Schmalzried TP. Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 2008; 90:1487-91. [PMID: 18594097 DOI: 10.2106/jbjs.f.00991] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
We previously reported wear data at a minimum of two years following thirty-four total hip replacements with a Marathon cross-linked polyethylene liner and twenty-four replacements with a conventional (gamma-sterilized-in-air) Enduron polyethylene liner. In this current study, with sequential five-year radiographs, wear rates were determined with use of linear regression analysis. The Marathon polyethylene had average wear rates of 15.4 mm(3)/yr and 8.0 mm(3)/million cycles. The Enduron polyethylene had average wear rates of 55.5 mm(3)/yr and 29.9 mm(3)/million cycles. The adjusted volumetric wear rate of the Marathon polyethylene was 73% lower than that of the Enduron polyethylene (p = 0.001). Osteolysis developed in eight of the twenty-four hips with an Enduron liner but was not apparent in any hip with a Marathon liner.
Collapse
Affiliation(s)
- Rudi G Bitsch
- Stiftung Orthopädische Universitätsklinik, Schlierbacher Landstrasse 200A, 69118 Heidelberg, Germany
| | | | | | | | | |
Collapse
|
40
|
|
41
|
Abstract
Orthopaedic surgeons have new tools that address the problem of aseptic loosening and osteolysis, and these tools are now in widespread clinical use. Hard-on-hard bearing couples as well as metal-on-highly cross-linked polyethylene bearing couples have lower volumetric wear rates and represent promising solutions to reduce the prevalence of osteolysis and aseptic loosening in total joint arthroplasty. Volumetric wear rates alone, however, do not completely predict the osteolytic potential that is also a function of particle composition, size, morphology, and a number of other particle characteristics. Host factors, including differing innate reactivities to wear products and adaptive immune responses, remain important but incompletely defined. Although the toxicologic significance of local and systemic elevations in metal ions has not been definitively established, monitoring patients with metal-on-metal bearings with serum metal ion levels can be useful to determine the state of the bearing. Furthermore, optimization of these bearing systems to further diminish wear and corrosion would be highly desirable.
Collapse
|
42
|
Khan M, Kuiper JH, Richardson JB. Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty? Proc Inst Mech Eng H 2007; 221:929-42. [DOI: 10.1243/09544119jeim270] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
High levels of cobalt and chromium ions are detected in the blood and urine of patients with metal-on-metal (MoM) hip replacement. These elements are released as a result of wear at the bearing surfaces. Wear rates depend on a multitude of factors, which include the bearing geometry, carbon content, manufacturing processes, lubrication, speed and direction of sliding of the surfaces, pattern of loading, and orientation of the components. In-vivo wear of MoM bearings cannot be reliably measured on X-rays because no distinction can be made between the bearing surfaces. Hip simulator studies have shown that wear rates are higher during the initial bedding-in phase and subsequently drop to very low levels. Accordingly, metal ion levels would be expected to decrease with the use of the bearing, measured as implantation time following surgery. However, several clinical studies have found that metal ion levels either gradually rise or fluctuate instead of decreasing to lower levels. Moreover, hip simulator studies predict that large-diameter bearings have lower wear rates than small-diameter bearings. In clinical studies, however, metal levels in patients with large-diameter bearings are unexpectedly higher than those in patients with small-diameter bearings. As a consequence, high cobalt ion levels in patients do not necessarily imply that their MoM bearings produce much wear debris at the time that their levels were measured; it may simply be due to accumulation of wear debris from the preceding time. Exercise-related cobalt rise may overcome this limitation and give a better assessment of the current wear status of a MoM bearing surface than a measure of cobalt levels only.
Collapse
Affiliation(s)
- M Khan
- Institute of Orthopaedics, Robert Jones and Agnes Hunt Orthopaedics Hospital, Oswestry, UK
- Centre for Science and Technology in Medicine, Keele University Hospital, Keele, UK
| | - J H Kuiper
- Institute of Orthopaedics, Robert Jones and Agnes Hunt Orthopaedics Hospital, Oswestry, UK
- Centre for Science and Technology in Medicine, Keele University Hospital, Keele, UK
| | - J B Richardson
- Institute of Orthopaedics, Robert Jones and Agnes Hunt Orthopaedics Hospital, Oswestry, UK
- Centre for Science and Technology in Medicine, Keele University Hospital, Keele, UK
| |
Collapse
|
43
|
Affatato S, Torrecillas R, Taddei P, Rocchi M, Fagnano C, Ciapetti G, Toni A. Advanced nanocomposite materials for orthopaedic applications. I. A long-term in vitro wear study of zirconia-toughened alumina. J Biomed Mater Res B Appl Biomater 2007; 78:76-82. [PMID: 16292765 DOI: 10.1002/jbm.b.30462] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The use of ceramic-on-ceramic (alumina- and zirconia-based) couplings in hip joint prostheses has been reported to produce lower wear rates than other combinations (i.e., metal-on-polyethylene and ceramic-on-polyethylene). The addition of zirconia into an alumina matrix (zirconia-toughened alumina, ZTA) has been reported to result in an enhancement of flexural strength, fracture toughness, and fatigue resistance. The development of new processing routes in nonaqueous media has allowed to obtain high-density ZTA nanocomposites with a very homogeneous microstructure and a significantly smaller and narrower particle-size distribution of zirconia than conventional powder mixing methods. The aim of the present study was to set up and validate a new ZTA nanocomposite by testing its biocompatibility and wear behavior in a hip-joint simulator in comparison with commercial alumina and experimental alumina specimens. The primary osteoblast proliferation onto ZTA nanocomposite samples was found to be not significantly different from that onto commercial alumina samples. After 7 million cycles, no significant differences were observed between the wear behaviors of the three sets of cups. In this light, it can be affirmed that ZTA nanocomposite materials can offer the option of improving the lifetime and reliability of ceramic joint prostheses.
Collapse
Affiliation(s)
- S Affatato
- Laboratorio di Tecnologia Medica, Istituti Ortopedici Rizzoli, Bologna, Italy.
| | | | | | | | | | | | | |
Collapse
|
44
|
Ziegler J, Amlang M, Bottesi M, Kirschner S, Witzleb WC, Günther KP. [Results for endoprosthetic care in patients younger than 50 years]. DER ORTHOPADE 2007; 36:325-36. [PMID: 17387449 DOI: 10.1007/s00132-007-1068-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Arthroplasty has become the most successful surgical procedure in developed countries. Replacement of severely damaged joints results in a substantial relief of pain, as the main symptom of osteoarthritis, in the majority of treated patients. With improved results in endoprosthetic surgery over the last decades, however, patients are increasingly undergoing the procedure to enhance their functional capacity and physical mobility. Especially younger patients, who cannot accept a restriction in their professional or sports activity, have become demanding candidates for surgery. This review summarizes the published results on shoulder, hip, knee, ankle and first metatarsophalangeal joint replacement in patients who are younger than 50 years of age. Mid- and long-term follow-up studies in this age group are evaluated in terms of prosthesis survival as well as functional improvement.
Collapse
Affiliation(s)
- J Ziegler
- Klinik und Poliklinik für Orthopädie, Universitätsklinikum Carl Gustav Carus Dresden an der Technischen Universität Dresden, Fetscherstrasse 74, 01307 Dresden, Deutschland.
| | | | | | | | | | | |
Collapse
|
45
|
Valentí JR, Del Río J, Amillo S. Catastrophic wear in a metal-on-ceramic total hip arthroplasty. J Arthroplasty 2007; 22:920-2. [PMID: 17826286 DOI: 10.1016/j.arth.2006.06.008] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2005] [Revised: 03/20/2006] [Accepted: 06/07/2006] [Indexed: 02/01/2023] Open
Abstract
A 51-year-old woman came to our clinic 6 months after a right total hip arthroplasty. She had noticed a slowly growing mass in the proximal thigh and referred progressive pain in the right groin. Plain radiography revealed premature acetabular cup aseptic loosening, and in the computed tomography study, a 14-cm-diameter mass was observed. Revision surgery was performed, showing a metal-on-ceramic bearing surface. The histologic analysis of surrounding tissues was reported as massive metallosis. Although occasionally chosen for primary or revision hip arthroplasty, there is little information available about the in vivo wear behavior of this combination. This important fact should be taken into account before considering such a surface alternative.
Collapse
Affiliation(s)
- Juan Ramon Valentí
- Department of Orthopedic Surgery and Traumatology, University Clinic of Navarre, Navarre, Spain
| | | | | |
Collapse
|
46
|
Luetzner J, Krummenauer F, Lengel AM, Ziegler J, Witzleb WC. Serum metal ion exposure after total knee arthroplasty. Clin Orthop Relat Res 2007; 461:136-42. [PMID: 17438467 DOI: 10.1097/blo.0b013e31806450ef] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
All metal implants release metal ions because of corrosion. This has been studied and debated, especially in metal-on-metal total hip arthroplasties. Total knee arthroplasty implants have large metal surface areas and therefore substantial potential for corrosion. We determined changes in serum levels of metal ions in 41 patients after cemented unconstrained total knee arthroplasty without patellar resurfacing, 18 with unilateral total knee arthroplasty (median, 66 months after surgery) and 23 patients with bilateral total knee arthroplasties (75 and 50 months after first and second surgeries, respectively). Serum concentrations of chromium, cobalt, and molybdenum were analyzed and related to the number of total knee arthroplasties and compared with those of 130 control patients without implants. The median chromium, cobalt, and molybdenum concentrations were 0.92, 3.28, and 2.55 microg/L, respectively, in the unilateral total knee arthroplasty sample and 0.98, 4.28, and 2.40 microg/L, respectively, in the bilateral total knee arthroplasty sample. We observed no difference between the serum levels in patients with unilateral and bilateral arthroplasties, but the serum levels of chromium and cobalt of both study groups were greater than those of the control group (less than 0.25 microg/L). The patients who had total knee arthroplasty had molybdenum profiles that were similar to those of the control group (median, 2.11 microg/L).
Collapse
Affiliation(s)
- Joerg Luetzner
- Department of Orthopaedic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany.
| | | | | | | | | |
Collapse
|
47
|
Klapperich C, Kaufman J, Wong J. Controlling and Assessing Cell–Biomaterial Interactions at the Micro- and Nanoscale. Biomaterials 2007. [DOI: 10.1201/9780849378898.ch10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
48
|
Affatato S, Leardini W, Jedenmalm A, Ruggeri O, Toni A. Larger diameter bearings reduce wear in metal-on-metal hip implants. Clin Orthop Relat Res 2007; 456:153-8. [PMID: 17065844 DOI: 10.1097/01.blo.0000246561.73338.68] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Metal-on-metal hip arthroplasty has the longest clinical history of all total arthroplasties. We asked whether large diameter femoral heads would result in less wear than those with small diameters. We also asked if there is a threshold diameter that ensures good wear behavior. We tested three batches of cast high-carbon cobalt-chromium-molybdenum hip implants (28 mm, 36 mm, and 54 mm diameters) in a hip simulator for 5 million cycles. We used bovine serum as lubricant and weighed the samples at regular intervals during testing. The 28-mm configuration had almost twice the wear of the 54-mm configuration, but we observed no difference between the 36-mm and the 54-mm configurations. The similarity in the wear performances of the larger configurations supports the presence of a threshold diameter that ensures good wear behavior.
Collapse
Affiliation(s)
- S Affatato
- Laboratorio di Tecnologia Medica, Istituti Ortopedici Rizzoli, Bologna, Italy.
| | | | | | | | | |
Collapse
|
49
|
Abstract
Total hip arthroplasty was originally indicated for older, sedentary patients because of concerns that catastrophic wear and failure would occur in younger and more active patients. With advances in implant design, tribology, and surgical technique, total hip arthroplasty has now become a viable option for younger patients seeking excellent pain relief and improvement in function. Long-term studies are needed to evaluate the outcome of hip arthroplasty in younger patients using the modern generation of implants and bearing surfaces.
Collapse
Affiliation(s)
- Peter F Sharkey
- Department of Orthopaedic Surgery, Jefferson Medical College, Philadelphia, Pennsylvania, USA
| | | | | |
Collapse
|
50
|
Dumbleton JH, D'Antonio JA, Manley MT, Capello WN, Wang A. The basis for a second-generation highly cross-linked UHMWPE. Clin Orthop Relat Res 2006; 453:265-71. [PMID: 17016228 DOI: 10.1097/01.blo.0000238856.61862.7d] [Citation(s) in RCA: 199] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Highly cross-linked ultra-high molecular weight polyethylene (UHMWPE) decreases wear at the hip by more than 50% compared with conventional UHMWPE. However, melted highly cross-linked polyethylene may be susceptible to fatigue cracking, and annealed highly cross-linked polyethylene may be susceptible to in vivo oxidation. The second-generation highly cross-linked UHMWPE (X3 HXPE) uses a sequential irradiation and annealing process. It preserves mechanical strength properties and has the highest survivorship in functional fatigue testing. The free radical content is low, and its performance under accelerated aging is the same as virgin UHMWPE. Hip simulator studies with 32-mm acetabular components demonstrated 97% wear reduction compared with conventional UHMWPE, and 62% compared with a clinically successful first-generation annealed highly cross-linked polyethylene. The crystallinity, density, and tensile strength of the X3 HXPE material was unchanged by oxidative challenge. X3 HXPE material articulating on cobalt-chromium alloy yields a volumetric wear rate very similar to that of metal-on-metal articulations, but eliminates the concerns of metal ion release. Wear particles generated from the X3 HXPE were the same size as those produced from conventional UHMWPE. Preliminary results suggest X3 HXPE can be used for cups larger than 36 mm.
Collapse
|