Kjærgaard K, Yilmaz S, Kaptein B, Overgaard S, Ding M. Measuring total hip arthroplasty liner wear using the EOS Imaging System: experimental and clinical results. Acta Orthop 2024; 95:530-535. [PMID: 39268932 PMCID: PMC11395818 DOI: 10.2340/17453674.2024.41912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Indexed: 09/15/2024] Open
Abstract
BACKGROUND AND PURPOSE The low-dose EOS Imaging System is an emerging tool for 3-dimensional measurements in orthopedics. The clinical feasibility for measuring total hip arthroplasty (THA) liner wear has not yet been investigated. We aimed to evaluate the feasibility of using EOS to measure THA liner wear by examining the experimental accuracy using a THA phantom and clinical precision of patients with THA, considering a clinically relevant precision at the 95% repeatability limit to be 0.2 mm. METHODS An experimental THA phantom with movable stem and a fixed cup with a plastic liner was constructed to simulate progressive 3D liner wear. Series of 11 pairs of radiographs with 50 μm femoral movement in between were obtained for each 3D axis in EOS. 30 patients with a THA were scanned twice using EOS to assess precision. Model-based radiostereometric analysis (RSA) was used for wear measurement. RESULTS The mean difference (true minus simulated wear) with standard deviation (SD) and 95% limits of agreement for experimental THA wear were 0.005 (0.037) and [-0.069 to 0.079] mm for the vertical (y) axis. The mean (SD) and 95% repeatability limit for precision for clinical measurement were -0.029 (0.105) and 0.218 mm. CONCLUSION Experimental THA liner wear using EOS was within clinically relevant tolerances and without bias. The clinical precision was just outside our defined clinically relevant precision. Compared with conventional RSA, EOS is less accurate and precise but may still be of value for certain clinical applications, provided larger sample size or longer follow-up are available.
Collapse
Affiliation(s)
- Kristian Kjærgaard
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Sibel Yilmaz
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Bart Kaptein
- Biomechanics and Imaging Group, Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Søren Overgaard
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense; Department of Clinical Research, University of Southern Denmark, Odense; Copenhagen University Hospital, Bispebjerg Department of Orthopaedic Surgery and Traumatology, Frederiksberg Hospital, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Ming Ding
- Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
2
|
Kaptein BL, Pijls B, Koster L, Kärrholm J, Hull M, Niesen A, Heesterbeek P, Callary S, Teeter M, Gascoyne T, Röhrl SM, Flivik G, Bragonzoni L, Laende E, Sandberg O, Solomon LB, Nelissen R, Stilling M. Guideline for RSA and CT-RSA implant migration measurements: an update of standardizations and recommendations. Acta Orthop 2024; 95:256-267. [PMID: 38819193 PMCID: PMC11141406 DOI: 10.2340/17453674.2024.40709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 04/08/2024] [Indexed: 06/01/2024] Open
Abstract
Opening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1]. By adhering to these guidelines, RSA studies will become more transparent and consistent in execution, presentation, reporting, and interpretation. Both authors and reviewers of scientific papers using RSA may use these guidelines, summarized in the Checklist, as a reference. Deviations from these guidelines should have the underlying rationale stated.
Collapse
Affiliation(s)
- Bart L Kaptein
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands.
| | - Bart Pijls
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Lennard Koster
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Johan Kärrholm
- Department of Orthopedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maury Hull
- Orthopedic Surgery Department, University of California, Davis, United States
| | - Abby Niesen
- Orthopedic Surgery Department, University of California, Davis, United States
| | - Petra Heesterbeek
- Orthopedic Research Department, Sint Maartenskliniek, Nijmegen, The Netherlands
| | - Stuart Callary
- Department of Orthopedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Matthew Teeter
- Department of Medical Biophysics, Western University, London, Canada
| | | | - Stephan M Röhrl
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| | - Gunnar Flivik
- Department of Orthopedics, Skane University Hospital, Lund, Sweden
| | | | - Elise Laende
- Department of Surgery, Dalhousie University, Halifax, Canada
| | | | - L Bogdan Solomon
- Department of Orthopedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Rob Nelissen
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Maiken Stilling
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
3
|
Taleb S, Broberg JS, Lanting BA, Teeter MG. Phantom validation of a novel RSA-based impingement metric to assess component-on-component impingement risk. Proc Inst Mech Eng H 2024; 238:483-487. [PMID: 38519832 PMCID: PMC11083746 DOI: 10.1177/09544119241238950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2024]
Abstract
Component-on-component impingement in total hip arthroplasty may lead to post-operative complications including dislocation. Despite numerous clinical studies focusing on reducing this risk, assessment methods remain limited to qualitative radiography, finite element analysis, and cadaver studies. There is a need for more precise measurements of impingement in the research setting. We aimed to validate a novel RSA-based impingement metric to measure component-on-component impingement in vivo. A phantom experiment of a standard metal-on-polyethylene total hip system was performed. RSA examinations were performed as typical for a traditional weight-bearing RSA exam for large joints. The phantom was placed in 10 possible impinged positions and one neutral position. Double exposure radiographs were taken to measure repeatability. The closest distance between the skirt of the head and the inner circumference of the acetabular cup liner was measured to assess impingement risk. Distances between the closest point of the hood to the edge of the cup in 10 impinged positions ranged from 0.05 to 1.03 mm, with the average being 0.67 mm. In the neutral position, the distance measured is 11.02 mm. Excellent repeatability was observed, with a standard deviation of 0.03 mm with an r value of 0.09. A validated RSA-based risk metric was established to evaluate in vivo hip impingement. A 1 mm threshold may be proposed to define impingement where distances approaching 1.00 mm are at a greater risk of impingement. This simplified metric holds promise for upcoming clinical studies on component-on-component impingement.
Collapse
Affiliation(s)
- Shahnaz Taleb
- Imaging Group, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Jordan S Broberg
- Imaging Group, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Brent A Lanting
- Division of Orthopedic Surgery, Department of Surgery, University Hospital, London Health Sciences Center, London, ON, Canada
| | - Matthew G Teeter
- Imaging Group, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| |
Collapse
|
4
|
Fallahnezhad K, Callary SA, O'Rourke D, Bahl JS, Thewlis D, Solomon LB, Taylor M. Corroboration of coupled musculoskeletal model and finite element predictions with in vivo RSA migration of an uncemented acetabular component. J Orthop Res 2024; 42:373-384. [PMID: 37526382 DOI: 10.1002/jor.25671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/18/2023] [Accepted: 07/26/2023] [Indexed: 08/02/2023]
Abstract
While finite element (FE) models have been used extensively in orthopedic studies, validation of their outcome metrics has been limited to comparison against ex vivo testing. The aim of this study was to validate FE model predictions of the initial cup mechanical environment against patient-matched in vivo measurements of acetabular cup migration using radiostereometric analysis (RSA). Tailored musculoskeletal and FE models were developed using a combination of three-dimensional (3D) motion capture data and clinical computerized tomography (CT) scans for a cohort of eight individuals who underwent primary total hip replacement and were prospectively enrolled in an RSA study. FE models were developed to calculate the mean modulus of cancellous bone, composite peak micromotion (CPM), composite peak strain (CPS) and percentage area of bone ingrowth. The RSA cup migration at 3 months was used to corroborate the FE output metrics. Qualitatively, all FE-predicted metrics followed a similar rank order as the in vivo RSA 3D migration data. The two cases with the lowest predicted CPM (<20 µm), lowest CPS (<0.0041), and high bone modulus (>917 MPa) were confirmed to have the lowest in vivo RSA 3D migration (<0.14 mm). The two cases with the largest predicted CPM (>80 µm), larger CPS (>0.0119) and lowest bone modulus (<472 MPa) were confirmed to have the largest in vivo RSA 3D migration (>0.78 mm). This study enabled the first corroboration between tailored musculoskeletal and FE model predictions with in vivo RSA cup migration. Investigation of additional patient-matched CT, gait, and RSA examinations may allow further development and validation of FE models.
Collapse
Affiliation(s)
- Khosro Fallahnezhad
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| | - Stuart A Callary
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Dermot O'Rourke
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Jasvir S Bahl
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
| | - Dominic Thewlis
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Lucian B Solomon
- Centre for Orthopaedics and Trauma Research (COTR), The University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Mark Taylor
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia
| |
Collapse
|
5
|
Polus JS, Vasarhelyi EM, Lanting BA, Teeter MG. Acetabular cup fixation with and without screws following primary total hip arthroplasty: migration evaluated by radiostereometric analysis. Hip Int 2024; 34:42-48. [PMID: 37016808 PMCID: PMC10787387 DOI: 10.1177/11207000231164711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 02/25/2023] [Indexed: 04/06/2023]
Abstract
BACKGROUND Early cup migration after total hip arthroplasty (THA) is correlated to late revision due to aseptic loosening. However, the use of screws for increased cup stability remains unclear and debated. The purpose of this study is to assess acetabular migration between cups fixated with and without the use of screws. METHODS Patients underwent primary THA using either a direct anterior (DA) or a direct lateral (DL) approach. The DA surgeon routinely supplemented cup fixation with 1 or 2 screws while the DL surgeon used no screws. At 7 follow-up visits up to 2 years post operation, patients underwent radiostereometric analysis (RSA) imaging for implant migration tracking. The primary outcome was defined as proximal cup migration measured with model-based RSA. RESULTS 68 patients were assessed up to 2 years post operation, n = 43 received screws and n = 25 did not. The use of screws had a significant effect on cup migration (p = 0.018). From 2 weeks to 2 years post operation, the total mean migration was 0.403 ± 0.681 mm and 0.129 ± 0.272 mm (p = 0.319) for cups with and without screws, respectively. The number of screws used also had a significant impact, with cups fixated with 1 screw migrating more than cups fixated with 2 (p = 0.013, mean difference 0.712 mm). CONCLUSIONS Acetabular cups fixated with only 1 screw resulted in greater migration than cups with no screws or 2 screws, though the mean magnitude was well under the 1.0 mm threshold for unacceptable migration. However, 3 of the 24 patients who received only 1 screw exceeded the 1.0 mm threshold for unacceptable migration. Ultimately, the results of this study show that the use of 2 screws to supplement cup fixation can provide good implant stability that is equivalent to a secure press-fit component with no screws.Clinical trial registration: ClinicalTrials.gov (NCT03558217).
Collapse
Affiliation(s)
- Jennifer S Polus
- School of Biomedical Engineering, Western University, London, Ontario, Canada
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Collaborative Specialization in Musculoskeletal Health Research, and Bone and Joint Institute, Western University, Canada
| | - Edward M Vasarhelyi
- Division of Orthopaedic Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - Brent A Lanting
- Division of Orthopaedic Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - Matthew G Teeter
- School of Biomedical Engineering, Western University, London, Ontario, Canada
- Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
- School of Biomedical Engineering, Collaborative Specialization in Musculoskeletal Health Research, and Bone and Joint Institute, Western University, Canada
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| |
Collapse
|
6
|
Bunting AC, Costi K, Chimutengwende-Gordon M, Callary SA, Pannach S, Nelson R, Howie DW, Solomon LB. Staged Revision Hip Arthroplasty With Femoral Impaction Bone Grafting for Prosthetic Joint Infections: Radiostereometric Analyses and Clinical Outcomes at Minimum 5-Year Follow-Up. J Arthroplasty 2023; 38:2716-2723.e1. [PMID: 37321515 DOI: 10.1016/j.arth.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 06/01/2023] [Accepted: 06/03/2023] [Indexed: 06/17/2023] Open
Abstract
BACKGROUND There are ongoing concerns regarding the use of bone graft following prosthetic joint infection and subsequent implant subsidence. The aim of this study was to determine whether the use of a cemented stem combined with femoral impaction bone grafting (FIBG) at second stage revision for infection results in stable femoral stem fixation, determined by accurate methods, and good clinical results. METHODS A prospective cohort of 29 patients underwent staged revision total hip arthroplasty for infection using an interval prosthesis followed by FIBG at the final reconstruction. The mean follow-up was 89 months (range, 8 to 167 months). Femoral implant subsidence was measured with radiostereometric analysis. Clinical outcomes included the Harris Hip Score, Harris Pain score and Société Internationale de Chirurgie Orthopédique et de Traumatologie activity scores. RESULTS At 2-years follow-up the median stem subsidence relative to femur was -1.36 mm (range, -0.31 to -4.98), while the cement subsidence relative to femur was -0.05 mm (range, 0.36 to -0.73). At 5-years follow-up, the median stem subsidence relative to femur was -1.89 mm (range, -0.27 to -6.35), while the cement subsidence relative to femur was -0.06 mm (range, 0.44 to -0.55). There were 25 patients who were confirmed infection-free after the second stage revision with FIBG. The median Harris Hip Score improved from 51 pre-operatively to 79 at 5 years (P = .0130), and Harris Pain score from 20 to 40 (P = .0038). CONCLUSIONS Stable femoral component fixation can be achieved with FIBG when reconstructing the femur after revision for infection without compromising infection cure rates and patient-reported outcomes.
Collapse
Affiliation(s)
- Alexandra C Bunting
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Kerry Costi
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | | | - Stuart A Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Susan Pannach
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Renjy Nelson
- Department of Infectious Diseases, Royal Adelaide Hospital, Adelaide, South Australia
| | - Donald W Howie
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Lucian Bogdan Solomon
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia; Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| |
Collapse
|
7
|
Hurry JK, Spurway AJ, Laende EK, Rehan S, Astephen Wilson JL, Dunbar MJ, El-Hawary R. A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty. Acta Orthop 2023; 94:555-559. [PMID: 38032252 PMCID: PMC10688435 DOI: 10.2340/17453674.2023.19669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 08/17/2023] [Indexed: 12/01/2023] Open
Abstract
BACKGROUND AND PURPOSE The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager. PATIENTS AND METHODS At a mean of 5 years post-surgery (range 1.4-7.5 years), 15 total knee arthroplasty (TKA) participants (mean age 67 years at the time of imaging, 12 female, 3 male) with RSA markers implanted during index surgery were scanned twice at the same visit in the EOS imager. Precision of marker-based analysis was calculated by comparing the position of the implant relative to the underlying bone between the 2 examinations. RESULTS The 95% limit of precision was 0.11, 0.04, and 0.15 mm along the x, y, and z axes, respectively and 0.15°, 0.20°, and 0.14° around the same axes. CONCLUSION This precision study has shown an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20°, well within published uniplanar values for conventional arthroplasty RSA, with the added benefit of weight-bearing imaging, a lower radiation dose, and without the need for a reference object during the scan.
Collapse
Affiliation(s)
- Jennifer K Hurry
- Department of Orthopaedic Surgery, IWK Health Centre, Halifax, Nova Scotia.
| | - Alan J Spurway
- Department of Orthopaedic Surgery, IWK Health Centre, Halifax, Nova Scotia
| | - Elise K Laende
- Division of Orthopaedic Surgery, Nova Scotia Health Authority, Halifax, Nova Scotia; Mechanical and Materials Engineering, Queen's University, Kingston, Ontario
| | - Saad Rehan
- Division of Orthopaedic Surgery, Nova Scotia Health Authority, Halifax, Nova Scotia
| | | | - Michael J Dunbar
- Division of Orthopaedic Surgery, Nova Scotia Health Authority, Halifax, Nova Scotia; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Ron El-Hawary
- Department of Orthopaedic Surgery, IWK Health Centre, Halifax, Nova Scotia; School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
8
|
Jørgensen PB, Krag-Nielsen N, Lindgren L, Mørup RMS, Kaptein B, Stilling M. Radiostereometric analysis: comparison of radiation dose and precision in digital and computed radiography. Arch Orthop Trauma Surg 2023; 143:5919-5926. [PMID: 36422666 DOI: 10.1007/s00402-022-04674-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 10/23/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Radiostereometric Analysis (RSA) is used to measure fixation of joint prosthesis. This study compared radiation dose and image quality of a digital radiography (DR) RSA system and a computed radiography (CR) RSA system in a clinical setting. METHODS RSA recordings of 24 hips and shoulders were analyzed. We compared two systems: (1) Arcoma T0 with ST-VI image plates and Profect CR-IR 363 reader to (2) AdoraRSA with CXDI-70C wireless DR detectors in a clinical uniplanar RSA set-up with a ± 20 degrees tube angulation and 35 cm × 43 cm detectors. Effective dose was calculated using dedicated software. Image quality was evaluated using calibration errors as calculated by the RSA software. RESULTS The mean dose for hips was 0.14 (SD 0.04) mSv in the CR system and 0.05 (SD 0.02) mSv in the DR system. The mean dose for shoulders was 0.16 (SD 0.07) mSv in the CR system and 0.09 (SD 0.03) mSv in the DR system. Radiation dose was 64% (p < 0.001) and 43% (p = 0.03) lower in the DR system compared with the CR system for hip and shoulder RSA, respectively. Image quality was better for the DR system with 60-80% less calibration errors compared to the CR system. CONCLUSION Owing to highly efficient detectors and added filtration at the x-ray tubes, the DR system considerably reduced radiation dose compared with the CR system without compromising image quality. Based on the findings in this study, we recommend replacing CR RSA systems with DR RSA systems. REGISTRATION Patients were selected from clinical studies performed on the two systems and approved by the local ethics committee [20060165, M-20100112, M-20070082, M-20110224, and 20070258] and registered with ClinicalTrials.gov [NCT00408096, NCT01289834, NCT00913679, NCT02311179, and NCT00679120].
Collapse
Affiliation(s)
- Peter Bo Jørgensen
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus N, Denmark.
| | | | - Lars Lindgren
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Rikke Margrethe Staghøj Mørup
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus N, Denmark
| | - Bart Kaptein
- Biomechanics and Imaging Group (BIG), Leiden University Medical Center, Leiden, The Netherlands
| | - Maiken Stilling
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens, Boulevard 99, 8200, Aarhus N, Denmark
| |
Collapse
|
9
|
Jørgensen PB, Jakobsen SS, Vainorius D, Homilius M, Hansen TB, Stilling M. Less early subsidence of cemented Exeter short stems compared with cemented Exeter standard stems in Dorr type A femurs. Bone Jt Open 2023; 4:507-515. [PMID: 37407021 DOI: 10.1302/2633-1462.47.bjo-2023-0008.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/07/2023] Open
Abstract
Aims The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems. Methods In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up. Results At three months, subsidence of the short stem -0.87 mm (95% confidence interval (CI) -1.07 to -0.67) was lower compared to the standard stem -1.59 mm (95% CI -1.82 to -1.36; p < 0.001). Both stems continued a similar pattern of subsidence until five-year follow-up. At five-year follow-up, the short stem had subsided mean -1.67 mm (95% CI -1.98 to -1.36) compared to mean -2.67 mm (95% CI -3.03 to -2.32) for the standard stem (p < 0.001). Subsidence was not influenced by preoperative bone quality (osteopenia vs normal) or cement mantle thickness. Conclusion The standard Exeter stem had more early subsidence compared with the short Exeter stem in patients with Dorr type A femora, but thereafter a similar migration pattern of subsidence until minimum five years follow-up. Both the standard and the short Exeter stems subside. The standard stem subsides more compared to the short stem in Dorr type A femurs. Subsidence of the Exeter stems was not affected by cement mantle thickness.
Collapse
Affiliation(s)
- Peter B Jørgensen
- AutoRSA Reseach Group Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Dovydas Vainorius
- Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
| | - Morten Homilius
- Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
| | - Torben B Hansen
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
- Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
| | - Maiken Stilling
- AutoRSA Reseach Group Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
10
|
Cao H, Sesselmann S, Xu J, Seehaus F, Forst R. How Do Classic (Static) RSA and Patient Motion Artifacts Affect the Assessment of Migration of a TKA Tibial Component? An In Vitro Study. Clin Orthop Relat Res 2023; 481:400-412. [PMID: 36398327 PMCID: PMC9831201 DOI: 10.1097/corr.0000000000002453] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 09/21/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND Classic (static) Roentgen stereophotogrammetric analysis (RSA) is the current gold standard to assess, in vivo, the migration of total joint arthroplasty components. To prevent potential patient motion artifacts during the acquisition of paired radiostereometric images, images must be taken by simultaneously firing both X-ray tubes. However, the influence of nonsynchronized RSA paired images or patient motion artifacts on the precision of RSA and the assessment of implant migration is not well understood. QUESTIONS/PURPOSES We assessed (1) the effect of possible patient motion on the precision of RSA and (2) apparent differences in implant migration among axes (in-plane and out-of-plane translations and in-plane and out-of-plane rotations) of possible motion artifacts. METHODS Radiographs of two tibial knee arthroplasty components, each fixed in two bone-implant models as a customized phantom, were taken in a uniplanar measurement setup. We evaluated both model-based (implant models from reversed engineering) and marker-based (additional attached implant markers) RSA approaches. Between the simulated reference and follow-up examinations, we used one of the bone-implant models to simulate patient motion and the other to simulate no patient motion in parallel. Two defined protocols were followed for each of the bone-implant models: no-motion and simulated motion protocols. RSA image pairs were analyzed using a model-based RSA software package (MBRSA 4.1, RSA core ). Precision was calculated through repeat examinations, and migration of the two components was assessed for comparison of the components with each other. Measurements were taken along the medial-lateral and posterior-anterior axes for translations and around the cranial-caudal axis for rotations. The maximum total point motion was measured for comparison between the two components. RESULTS The effect of simulated patient motion was generally small, except in the cranial-caudal axis, but the induced imprecision associated with motion was larger in model-based RSA than it was in marker-based RSA. The mean ± standard deviation values of precision in model-based RSA were 0.035 ± 0.015 mm, 0.045 ± 0.014 mm, and 0.049 ± 0.036 mm greater than those in marker-based RSA, in accordance with the simulated motion protocol in translations along the medial-lateral axis (0.018 ± 0.004 mm; p = 0.01), along the posterior-anterior axis (0.018 ± 0.007 mm; p = 0.003), and rotations around the cranial-caudal axis (0.017 ± 0.006 mm; p = 0.02). Apparent differences in implant migration were the greatest for the maximum total point motion. The maximum total point motion increased from 0.038 ± 0.007 mm for the no-motion protocol to 1.684 ± 0.038 mm (p < 0.001) for the simulated motion protocol in marker-based RSA, and from 0.101 ± 0.027 mm for the no-motion protocol to 1.973 ± 0.442 mm (p < 0.001) for the simulated motion protocol in model-based RSA, and was the worst-case scenario regarding patient motion artifacts. CONCLUSION Patient motion exceeding 1 mm or 1° on nonsynchronized RSA images affects measurement errors regarding the detection of migration of a tibial component. In clinical RSA studies, the effect of patient motion on the assessment of implant migration should be of particular concern, even if clinical RSA systems have acceptable precision. Specially trained radiographers are crucial for correctly acquiring radiographs, especially when simultaneous radiography exposures are not electronically automated. In general, RSA requires synchronized image acquisition, and this should be the state-of-the-art. CLINICAL RELEVANCE In clinical RSA studies, precision assessed by repeat examinations may not be reliable using the current standards that are widely used in radiology departments. When assessing implant migration for reliability, comparison of the maximum total point motion between the tested (simulated motion) implant and baseline (no-motion) implant, as in this study, is advocated because of the accurate detection of patient motion artifacts.
Collapse
Affiliation(s)
- Han Cao
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- Department of Orthopaedic Surgery, Taizhou Second People’s Hospital, Taizhou, PR China
| | - Stefan Sesselmann
- Institute for Medical Technology, Ostbayerische Technische Hochschule Amberg-Weiden, Weiden, Germany
| | - Jing Xu
- Department of Orthopaedic Surgery, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, PR China
| | - Frank Seehaus
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
- Department of Orthopaedic and Trauma Surgery, University Hospital Erlangen, Erlangen, Germany
| | - Raimund Forst
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
11
|
Cao H. Accuracy of radiostereometric analysis using a motorized Roentgen system in a pilot study for clinical simulation. Med Eng Phys 2023; 111:103929. [PMID: 36792244 DOI: 10.1016/j.medengphy.2022.103929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 10/26/2022] [Accepted: 11/21/2022] [Indexed: 11/25/2022]
Abstract
Radiostereometric analysis (RSA) is routinely implemented with two paired Roentgen tubes for three-dimensional (3D) implant migration measurements. A conventional set-up of one stationary tube and one mobile could be time-consuming. Utilizing two customized ceiling-mounted tubes is normally associated with investment costs. Thus, a pilot set-up of a motorized system (single Roentgen source) for radiostereometric image acquisition may be a time-saving and space-efficient alternative. RSA using the motorized system is feasible in this study as a non-synchronized image acquisition technique, however, patient motion may occur and influence the assessment of implant migration. The phantom study aimed to assess accuracy of RSA using the motorized Roentgen system in this in vitro study. Accuracy values of translations and rotations were ±0.29 mm and ±0.48° for the single Roentgen source RSA set-up and ±0.26 mm and ±0.48° for the conventional RSA set-up. This study was also performed to simulate potential patient motion during exposure intervals between paired image acquisition. RSA using the motorized system is able to implement RSA with acceptable accuracy. In general, RSA with synchronized image acquisition is the gold standard to access in vivo implant migration with the highest accuracy. Patient motion exists in non-synchronized image acquisition techniques and results in RSA-related motion artifacts. Then we introduced what RSA-related motion artifacts are. The uniplanar calibration cage applied in the study has a few fiducial and control markers, and some of the markers were occluded in radiographs. Whereas, the number of markers in the calibration cage is correlated with accuracy of 3D implant reconstruction.
Collapse
Affiliation(s)
- Han Cao
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany; Department of Orthopaedic Surgery, Taizhou Second People's Hospital, 225599 Taizhou, China.
| |
Collapse
|
12
|
Miura T, Kijima H, Kimura R, Watanabe J, Okazaki Y, Miyakoshi N. Efficacy and Safety of Acetabular Cup without Screw Fixation in Total Hip Arthroplasty: A Systematic Review and Meta-Analysis. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:1058. [PMID: 36013524 PMCID: PMC9413682 DOI: 10.3390/medicina58081058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/20/2022] [Accepted: 08/02/2022] [Indexed: 11/16/2022]
Abstract
Background and Objectives: Adequate initial fixation of the uncemented acetabular component in total hip arthroplasty is necessary to achieve long-term survival. Although screw fixation contributes to improved cup stability, there is currently no consensus on the use of this method. This study aimed to assess the existing randomized controlled trials (RCTs) on the efficacy and safety of cup fixation in total hip arthroplasty without screws. Materials and Methods: We searched the EMBASE, MEDLINE, Cochrane Central Register of Controlled Trials, World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov databases to identify RCTs published before February 2022. Primary outcomes were reoperation, cup migration, and Harris Hip Score. Secondary outcomes were the presence of a radiolucent line in the acetabular region, translation and rotation movement, and polyethylene wear. We conducted meta-analyses using the random-effects models. The revised Cochrane risk-of-bias tool was used to assess the risk of bias for outcomes of interest; the Grading of Recommendations, Assessment, Development, and Evaluation approach was used to summarize the body of evidence. Results: We included six reports from four studies. Total hip arthroplasty without screw fixation to the acetabular cup had little to no effect on reoperation (pooled relative risk, 0.98; 95% confidence interval, 0.14-6.68; I2 = 0%), cup migration (pooled relative risk, 1.72; 95% confidence interval, 0.29-10.33; I2 = 1%), Harris Hip Score (mean difference, 1.19; 95% confidence interval, -1.31-3.70; I2 = 0%), radiolucent line (pooled relative risk, 5.91; 95% confidence interval, 0.32-109.35), translation and rotation of all axes, and polyethylene wear (mean difference, 0.01; 95% confidence interval, -0.01-0.04; I2 = 0%), with very low certainty of evidence on all measures. Conclusions: The efficacy of acetabular cups without screw fixation in total hip arthroplasty remains uncertain, suggesting the need for prudent clinical application. Further large-scale, well-designed studies with low risk of bias are required.
Collapse
Affiliation(s)
- Takanori Miura
- Department of Orthopedic Surgery, Tazawako Hospital 17-1 Ukiyozaka Obonai, Tazawako, Senboku 014-1201, Akita, Japan
| | - Hiroaki Kijima
- Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Akita, Japan
| | - Ryota Kimura
- Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Akita, Japan
| | - Jun Watanabe
- Scientific Research Workshop Peer Support Group (SRWS-PSG), Osaka, Osaka, Japan
- Department of Surgery, Division of Gastroenterological, General and Transplant Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke City 329-0498, Tochigi, Japan
- Center for Community Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke City 329-0498, Tochigi, Japan
| | - Yuji Okazaki
- Scientific Research Workshop Peer Support Group (SRWS-PSG), Osaka, Osaka, Japan
- Department of Emergency Medicine, Hiroshima City Hiroshima Citizens Hospital, 7-33, Motomachi, Naka-ku, Hiroshima City 730-8518, Hiroshima, Japan
| | - Naohisa Miyakoshi
- Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Akita, Japan
| |
Collapse
|
13
|
Gurung B, Liu P, Harris PDR, Sagi A, Field RE, Sochart DH, Tucker K, Asopa V. Artificial intelligence for image analysis in total hip and total knee arthroplasty : a scoping review. Bone Joint J 2022; 104-B:929-937. [PMID: 35909383 DOI: 10.1302/0301-620x.104b8.bjj-2022-0120.r2] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
AIMS Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. METHODS The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O'Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy. RESULTS Of the 455 studies identified, only 12 were suitable for inclusion. Nine reported implant identification and three described predicting risk of implant failure. Of the 12, three studies compared AI performance with orthopaedic surgeons. AI-based implant identification achieved AUC 0.992 to 1, and most algorithms reported an accuracy > 90%, using 550 to 320,000 training radiographs. AI prediction of dislocation risk post-THA, determined after five-year follow-up, was satisfactory (AUC 76.67; 8,500 training radiographs). Diagnosis of hip implant loosening was good (accuracy 88.3%; 420 training radiographs) and measurement of postoperative acetabular angles was comparable to humans (mean absolute difference 1.35° to 1.39°). However, 11 of the 12 studies had several methodological limitations introducing a high risk of bias. None of the studies were externally validated. CONCLUSION These studies show that AI is promising. While it already has the ability to analyze images with significant precision, there is currently insufficient high-level evidence to support its widespread clinical use. Further research to design robust studies that follow standard reporting guidelines should be encouraged to develop AI models that could be easily translated into real-world conditions. Cite this article: Bone Joint J 2022;104-B(8):929-937.
Collapse
Affiliation(s)
- Binay Gurung
- South West London Elective Orthopaedic Centre, Epsom, UK
| | - Perry Liu
- South West London Elective Orthopaedic Centre, Epsom, UK
| | | | - Amit Sagi
- South West London Elective Orthopaedic Centre, Epsom, UK.,Barzilai Medical Centre, Ashkelon, Israel
| | - Richard E Field
- South West London Elective Orthopaedic Centre, Epsom, UK.,St George's, University of London, London, UK
| | | | - Keith Tucker
- South West London Elective Orthopaedic Centre, Epsom, UK.,Orthopaedics Data Evaluation Panel, London, UK
| | - Vipin Asopa
- South West London Elective Orthopaedic Centre, Epsom, UK
| |
Collapse
|
14
|
Niesen AE, Garverick AL, Howell SM, Hull ML. Error in Maximum Total Point Motion of a Tibial Baseplate is Lower with a Reverse-Engineered Model Versus a CAD Model Using Model-Based Radiosteremetric Analysis. J Biomech 2022; 143:111267. [DOI: 10.1016/j.jbiomech.2022.111267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 07/27/2022] [Accepted: 08/17/2022] [Indexed: 10/15/2022]
|
15
|
Jensen ML, Olsen BS, Nyring MRK, Yilmaz M, Petersen MM, Flivik G, Rasmussen JV. Implant migration and functional outcome of Reverse Shoulder Lateralized Glenosphere Line Extension System: a study protocol for a randomized controlled trial. Trials 2022; 23:579. [PMID: 35854390 PMCID: PMC9295266 DOI: 10.1186/s13063-022-06482-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 06/18/2022] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Inferior scapular notching is a complication unique to reverse shoulder arthroplasty. The most efficient technique to avoid inferior scapular notching has been reported to be lateralization of the glenoid offset. This study aims to compare radiological and functional outcomes of the DELTA Xtend® Reverse Shoulder System Lateralized Glenosphere Line Extension (intervention group) with the Standard DELTA Xtend® Reverse Shoulder System (control group). We hypothesize that the lateralization improves the patient outcome by decreasing the risk of inferior scapular notching without increasing the risk of migration and loosening of glenoid component. METHODS In this randomized controlled trial, all Danish citizens with rotator cuff arthropathy or degeneration of the glenohumeral joint with severe posterior wear and allocated for a reverse total shoulder arthroplasty at the department of orthopaedic surgery at Herlev and Gentofte Hospital, Copenhagen University Hospital, will be considered for participation. The exclusion criteria are as follows: below 50 years of age, cognitive or linguistic impairment, insufficient glenoid bone stock, previous fracture in the upper extremity and autoimmune-mediated inflammatory arthritis. There will be included a total of 122 patients of which 56 will participate in the radiostereometric analysis. This number of patients allows 20% to drop out. The co-primary outcomes are the pattern and magnitude of the migration of the glenoid component assessed by radiostereometric analysis and the Western Ontario Osteoarthritis of the Shoulder index. The secondary outcomes are inferior scapular notching, patient-reported and functional outcomes (Oxford shoulder score, Constant-Murley score and pain), side effects and complications, changes in bone mineral density and economy. The included patients will be examined before the surgery, within 1 week and 3, 6, 12 and 24 months after. DISCUSSION No previous studies have compared the conventional reverse shoulder arthroplasty with the lateralized reverse shoulder arthroplasty in a randomized controlled trial regarding migration and functional outcome. Furthermore, radiostereometric analysis has not been used to evaluate the migration of reverse shoulder arthroplasty in a randomized controlled trial. This study intends to determine which treatment has the most optimal outcome for the benefit of future patients with an indication for reverse shoulder arthroplasty. TRIAL REGISTRATION The study has been notified to Pactius and has approval number P-2021-231. Furthermore, the study will be registered on Clinicaltrials.gov before starting the inclusion.
Collapse
Affiliation(s)
- Marie Louise Jensen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark.
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
| | - Bo S Olsen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Marc R K Nyring
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Müjgan Yilmaz
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
| | - Michael M Petersen
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Gunnar Flivik
- Department of Orthopedic Surgery, Skaane University Hospital, Lund University, Lund, Sweden
| | - Jeppe V Rasmussen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Copenhagen University Hospital, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
16
|
Fontalis A, Haddad FS. Roentgen stereophotogrammetric analysis: still a very valuable tool in the orthopaedic research armamentarium. Bone Joint Res 2022; 11:210-213. [PMID: 35369732 PMCID: PMC9057520 DOI: 10.1302/2046-3758.114.bjr-2021-0593.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Affiliation(s)
- Andreas Fontalis
- Division of Surgery & Interventional Science, University College London, London, UK.,Department of Trauma and Orthopaedics, University College London Hospitals NHS Foundation Trust, London, UK
| | - Fares S Haddad
- Division of Surgery & Interventional Science, University College London, London, UK.,Department of Trauma and Orthopaedics, University College London Hospitals NHS Foundation Trust, London, UK.,Institute of Sport, Exercise and Health, London, UK.,The Bone & Joint Journal , The British Editorial Society of Bone & Joint Surgery, London, UK
| |
Collapse
|
17
|
Abstract
Objectives: Methods: Results: Conclusions:
Collapse
|
18
|
Van de Kleut ML, Yuan X, Athwal GS, Teeter MG. Are short press-fit stems comparable to standard-length cemented stems in reverse shoulder arthroplasty? A prospective, randomized clinical trial. J Shoulder Elbow Surg 2022; 31:580-590. [PMID: 34968694 DOI: 10.1016/j.jse.2021.11.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 11/10/2021] [Accepted: 11/16/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND The literature comparing humeral implants in reverse shoulder arthroplasty is sparse. With minimal supporting literature, there has been a trend away from standard-length cemented humeral implants to press-fit stems and, recently, to shorter-stem implants. It is known that early implant migration, within the first 2 years postoperatively, is predictive of later implant loosening and possible revision surgery. Therefore, the purpose of this study was to compare clinical outcomes and implant migration between cemented standard-length humeral stems and press-fit short stems using model-based radiostereometric analysis. METHODS After a power analysis, 41 shoulders were prospectively randomized to receive either a cemented standard-length or press-fit short humeral stem for primary reverse shoulder arthroplasty between July 2017 and June 2019. Following surgery, participants were imaged with stereo radiographs acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem at each time point was compared with baseline, with differences in migration between cohorts assessed using a mixed-effects model with the Bonferroni test for multiple comparisons. Patient-reported outcome measures (Subjective Shoulder Value; American Shoulder and Elbow Surgeons shoulder score; Simple Shoulder Test score; Disabilities of the Arm, Shoulder and Hand score; and Constant score) were also compared. RESULTS At 6 months (P = .025), 1 year (P = .004), and 2 years (P = .001) postoperatively, press-fit short stems migrated significantly more than cemented stems along the superior-inferior translation axis; in addition, they showed greater total translation at 2 years (P = .003). Mean total translation (± standard deviation) at 2 years was 0.4 ± 0.2 mm and 1.0 ± 1.1 mm for the cemented and press-fit cohorts, respectively. Mean migration between the 1- and 2-year time points was minimal for both stem fixation groups along all axes (<0.1 mm and 0.6°). There was no difference in active range of motion, pain, or validated outcome measures between the cohorts at 2 years (P ≥ .170). CONCLUSION This randomized clinical trial shows that press-fit short humeral stems subside substantially more than standard-length cemented stems but ultimately achieve stability from 1 year through 2 years. Conversely, no significant differences were observed in clinical outcomes between cohorts.
Collapse
Affiliation(s)
- Madeleine L Van de Kleut
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; School of Biomedical Engineering, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada
| | - Xunhua Yuan
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - George S Athwal
- Lawson Health Research Institute, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Roth
- McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, ON, Canada
| | - Matthew G Teeter
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.
| |
Collapse
|
19
|
Okowinski M, Hjorth MH, Mosegaard SB, Jürgens-Lahnstein JH, Storgaard Jakobsen S, Hedevang Christensen P, Kold S, Stilling M. Ten-year comparison of two different techniques for femoral bone cavity preparation-broaching versus compaction in patients with cementless total hip arthroplasty : a randomized radiostereometric study of 30 total hip arthroplasties in 15 patients operated bilaterally. Bone Jt Open 2021; 2:1035-1042. [PMID: 34865512 PMCID: PMC8711659 DOI: 10.1302/2633-1462.212.bjo-2021-0152.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Aims Femoral bone preparation using compaction technique has been shown to preserve bone and improve implant fixation in animal models. No long-term clinical outcomes are available. There are no significant long-term differences between compaction and broaching techniques for primary total hip arthroplasty (THA) in terms of migration, clinical, and radiological outcomes. Methods A total of 28 patients received one-stage bilateral primary THA with cementless femoral stems (56 hips). They were randomized to compaction on one femur and broaching on the contralateral femur. Overall, 13 patients were lost to the ten-year follow-up leaving 30 hips to be evaluated in terms of stem migration (using radiostereometry), radiological changes, Harris Hip Score, Oxford Hip Score, and complications. Results Over a mean follow-up period of 10.6 years, the mean stem subsidence was similar between groups, with a mean of -1.20 mm (95% confidence interval (CI) -2.28 to -0.12) in the broaching group and a mean of -0.73 mm (95% CI -1.65 to 0.20) in the compaction group (p = 0.07). The long-term migration patterns of all stems were similar. The clinical and radiological outcomes were similar between groups. There were two intraoperative fractures in the compaction group that were fixed with cable wire and healed without complications. No stems were revised. Conclusion Similar stem subsidence and radiological and clinical outcomes were identified after the use of compaction and broaching techniques of the femur at long-term follow-up. Only the compaction group had intraoperative periprosthetic femur fractures, but there were no long-term consequences of these. Cite this article: Bone Jt Open 2021;2(12):1035–1042.
Collapse
Affiliation(s)
- Maciej Okowinski
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Mette Holm Hjorth
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
| | - Sebastian Breddam Mosegaard
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Jonathan Hugo Jürgens-Lahnstein
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark
| | - Stig Storgaard Jakobsen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark
| | | | - Søren Kold
- Department of Orthopedics, Aalborg University Hospital, Aalborg, Denmark
| | - Maiken Stilling
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark.,Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark.,Department of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
20
|
Dutrisac S, Brannen M, Hoshizaki TB, Frei H, Petel OE. A Parametric Analysis of Embedded Tissue Marker Properties and Their Effect on the Accuracy of Displacement Measurements. J Biomech Eng 2021; 143:111011. [PMID: 34159365 DOI: 10.1115/1.4051527] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Indexed: 02/05/2023]
Abstract
Datasets obtained from cadaveric experimentation are broadly used in validating finite element models of head injury. Due to the complexity of such measurements in soft tissues, experimentalists have relied on tissue-embedded radiographic or sonomicrometry tracking markers to resolve tissue motion caused by impulsive loads. Dynamic coupling of markers with the surrounding tissue has been a previous concern, yet a thorough sensitivity investigation of marker influences on tissue deformation has not been broadly discussed. Technological improvements to measurement precision have bolstered confidence in acquired data; however, precision is often conflated with accuracy; the inclusion of markers in the tissue may alter its natural response, resulting in a loss of accuracy associated with an altered displacement field. To gain an understanding of how marker properties may influence the measured response to impact, we prepared a set of nine marker designs using a Taguchi L9 array to investigate marker design choice sensitivity. Each of these designs was cast into a block of tissue simulant and subjected to repeated drop tests. Vertical displacement was measured and compared to the response of the neat material, which contained massless tracking markers. Medium density and medium stiffness markers yielded the least deviation from the neat material response. The results provide some design guidelines indicating the importance of maintaining marker matrix density ratio below 1.75 and marker stiffness below 1.0 MPa. These properties may minimize marker interference in tissue deformation. Overall, embedded marker properties must be considered when measuring the dynamic response of tissue.
Collapse
Affiliation(s)
- Scott Dutrisac
- Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - MacKenzie Brannen
- Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - T Blaine Hoshizaki
- School of Human Kinetics, University of Ottawa, Ottawa, ON K1S 5S9, Canada
| | - Hanspeter Frei
- Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Oren E Petel
- Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| |
Collapse
|
21
|
Mjöberg B. Hip prosthetic loosening: A very personal review. World J Orthop 2021; 12:629-639. [PMID: 34631447 PMCID: PMC8472441 DOI: 10.5312/wjo.v12.i9.629] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 05/03/2021] [Accepted: 08/03/2021] [Indexed: 02/06/2023] Open
Abstract
Hip prosthetic loosening is often difficult to detect at an early stage, and there has been uncertainty for a long time as to when the loosening occurs and thus to the basic causes. By comparing different diagnostic methods, we found that loosening is best defined as prosthetic migration and measured by radiostereometric analysis. Convincing evidence indicates that poor interlock, poor bone quality, and resorption of a necrotic bone bed may initiate loosening during or shortly after surgery; this forms the basis of the theory of early loosening. Biomechanical factors do affect the subsequent progression of loosening, which may increase subclinically during a long period of time. Eventually, the loosening may be detected on standard radiographs and may be interpreted as late loosening but should to be interpreted as late detection of loosening. The theory of early loosening explains the rapid early migration, the development of periprosthetic osteolysis and granulomas, the causality between wear and loosening, and largely the epidemiology of clinical failure of hip prostheses. Aspects discussed are definition of loosening, the pattern of early migration, the choice of migration threshold, the current understanding of loosening, a less exothermic bone cement, cemented taper-slip stems, a new exciting computed tomography-based technique for simpler implant migration studies, and research suggestions.
Collapse
Affiliation(s)
- Bengt Mjöberg
- Department of Orthopedics, Lund University, Lund SE-221 00, Sweden
| |
Collapse
|
22
|
Niesen AE, Hull ML. Propagation of registration error into maximum total point motion to analyze tibial baseplate stability at six months using marker-based and model-based RSA. J Biomech 2021; 127:110651. [PMID: 34371473 DOI: 10.1016/j.jbiomech.2021.110651] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 07/05/2021] [Accepted: 07/25/2021] [Indexed: 11/28/2022]
Abstract
Maximum total point motion (MTPM) of a tibial baseplate at 6 months is used to predict long-term aseptic loosening after total knee arthroplasty. However, the propagation of registration error into MTPM for stable baseplates (i.e. baseplates with MTPM < 0.5 mm) manifested as bias (i.e. systematic error) and precision (i.e. random error) has not been quantified and compared to the 6-month stability limit for marker-based and model-based RSA, which have different magnitudes of registration error. To determine the bias and precision in MTPM for stable baseplates, registration errors in six degrees of freedom reported in the literature for marker-based and model-based RSA were applied to an example baseplate using computer simulations. Results revealed that the bias in MTPM for stable baseplates with model-based RSA is three to four times that of marker-based RSA, and that the precision in MTPM for stable baseplates with model-based RSA is double that of marker-based RSA. This assessment of bias and precision in MTPM for stable baseplates led to a method for adjusting the 6-month stability limit for model-based RSA where half the width of the 95% confidence interval on the mean MTPM and the bias in MTPM for marker-based RSA were subtracted from 0.5 mm to compute true MTPM. The bias in MTPM and half the width of the 95% confidence interval on the mean MTPM for model-based RSA were then added to the true MTPM to obtain the adjusted stability limit for model-based RSA which ranged from 0.57 mm to 0.64 mm.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA.
| | - Maury L Hull
- Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA; Department of Mechanical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA; Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento CA, 95817, USA.
| |
Collapse
|
23
|
Favre P, Maquer G, Henderson A, Hertig D, Ciric D, Bischoff JE. In Silico Clinical Trials in the Orthopedic Device Industry: From Fantasy to Reality? Ann Biomed Eng 2021; 49:3213-3226. [PMID: 33973129 PMCID: PMC8110242 DOI: 10.1007/s10439-021-02787-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Accepted: 04/24/2021] [Indexed: 11/24/2022]
Abstract
The orthopedic device industry relies heavily on clinical evaluation to confirm the safety, performance, and clinical benefits of its implants. Limited sample size often prevents these studies from capturing the full spectrum of patient variability and real-life implant use. The device industry is accustomed to simulating benchtop tests with numerical methods and recent developments now enable virtual "in silico clinical trials" (ISCT). In this article, we describe how the advancement of computer modeling has naturally led to ISCT; outline the potential benefits of ISCT to patients, healthcare systems, manufacturers, and regulators; and identify how hurdles associated with ISCT may be overcome. In particular, we highlight a process for defining the relevant patient risks to address with ISCT, the utility of a versatile software pipeline, the necessity to ensure model credibility, and the goal of limiting regulatory uncertainty. By complementing-not replacing-traditional clinical trials with computational evidence, ISCT provides a viable technical and regulatory strategy for characterizing the full spectrum of patients, clinical conditions, and configurations that are embodied in contemporary orthopedic implant systems.
Collapse
Affiliation(s)
| | - Ghislain Maquer
- Zimmer Biomet, Sulzerallee 8, 8404 , Winterthur, Switzerland
| | - Adam Henderson
- Zimmer Biomet, Sulzerallee 8, 8404 , Winterthur, Switzerland
| | - Daniel Hertig
- Zimmer Biomet, Sulzerallee 8, 8404 , Winterthur, Switzerland
| | - Daniel Ciric
- Zimmer Biomet, Sulzerallee 8, 8404 , Winterthur, Switzerland
| | | |
Collapse
|
24
|
Koster LA, Meinardi JE, Kaptein BL, Van der Linden-Van der Zwaag E, Nelissen RGHH. Two-year RSA migration results of symmetrical and asymmetrical tibial components in total knee arthroplasty: a randomized controlled trial. Bone Joint J 2021; 103-B:855-863. [PMID: 33934647 DOI: 10.1302/0301-620x.103b5.bjj-2020-1575.r2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS). METHODS A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively. RESULTS A linear mixed-effect model using RSA data of 31 asymmetrical and 38 symmetrical TKAs did not show a difference in mean MTPM migration pattern of the tibial or femoral components. Mean tibial component MTPM at two years postoperative of the asymmetrical TKA design was 0.93 mm and 1.00 mm for the symmetrical design. For the femoral component these values were 1.04 mm and 1.14 mm, respectively. No significant differences were observed in other migration parameters or in clinical and PROM measurements. CONCLUSION The TKA design with an asymmetrical tibial component has comparable component migration with the proven TKA with a symmetrical tibial component. This suggests the risk of long-term aseptic loosening of the two designs is comparable. Cite this article: Bone Joint J 2021;103-B(5):855-863.
Collapse
Affiliation(s)
- Lennard A Koster
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Joris E Meinardi
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - Bart L Kaptein
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | | | - Rob G H H Nelissen
- Biomechanics and Imaging Group, Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
25
|
Niesen AE, Hull ML. Propagation of registration errors into the change in maximum total point motion for determining stability of tibial baseplates. Comput Methods Biomech Biomed Engin 2021; 24:1019-1025. [PMID: 33400600 DOI: 10.1080/10255842.2020.1865324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The change in maximum total point motion (ΔMTPM) is used to predict long-term risk of tibial baseplate loosening, however, effects of registration error on ΔMTPM have not been quantified for marker-based and model-based radiostereometric analysis (RSA). Registration errors for marker-based and model-based RSA were applied to a stable tibial baseplate in MATLAB simulations to determine the bias and precision in ΔMTPM and the proportions of baseplates which fell above the continuous migration stability limit. No bias error occurred, however, the precision of ΔMTPM was twice as large for model-based RSA than marker-based RSA, resulting in about 25% of stable baseplates falling above the continuous migration stability limit for model-based RSA. Reseachers should be aware of these limitations when applying this stability limit to assess tibial baseplate stability using model-based RSA.
Collapse
Affiliation(s)
- Abigail E Niesen
- Department of Biomedical Engineering, University of California Davis, Davis, CA, USA
| | - Maury L Hull
- Department of Biomedical Engineering, University of California Davis, Davis, CA, USA.,Department of Mechanical Engineering, University of California Davis, Davis, CA, USA.,Department of Orthopaedic Surgery, University of California Davis Medical Center, Sacramento, CA, USA
| |
Collapse
|
26
|
Perelgut ME, Polus JS, Lanting BA, Teeter MG. The effect of femoral stem collar on implant migration and clinical outcomes following direct anterior approach total hip arthroplasty. Bone Joint J 2020; 102-B:1654-1661. [PMID: 33249909 DOI: 10.1302/0301-620x.102b12.bjj-2019-1428.r1] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
AIMS The direct anterior (DA) approach has been associated with rapid patient recovery after total hip arthroplasty (THA) but may be associated with more frequent femoral complications including implant loosening. The objective of this study was to determine whether the addition of a collar to the femoral stem affects implant migration, patient activity, and patient function following primary THA using the DA approach. METHODS Patients were randomized to either a collared (n = 23) or collarless (n = 26) cementless femoral stem implanted using the DA approach. Canal fill ratio (CFR) was measured on the first postoperative radiographs. Patients underwent a supine radiostereometric analysis (RSA) exam postoperatively on the day of surgery and at two, four, six, 12, 26, and 52 weeks postoperatively. Patient-reported outcome measures (Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index, the 12-item Short Form Health Survey Mental and Physical Score, and University of California, Los Angeles (UCLA) Activity Score) were measured preoperatively and at each post-surgery clinic visit. Activity and function were also measured as the weekly average step count recorded by an activity tracker, and an instrumented timed up-and-go (TUG) test in clinic, respectively. RESULTS Comparing the RSA between the day of surgery baseline exam to two weeks postoperatively, subsidence was significantly lower (mean difference 2.23 mm (SD 0.71), p = 0.023) with collared stems, though these patients had a greater CFR (p = 0.048). There was no difference (p = 0.426) in subsidence between stems from a two-week baseline through to one year postoperatively. There were no clinically relevant differences in PROMs; and there was no difference in the change in activity (p = 0.078) or the change in functional capacity (p = 0.664) between the collared stem group and the collarless stem group at any timepoint. CONCLUSION Presence of a collar on the femoral stem resulted in reduced subsidence during the first two postoperative weeks following primary THA using the DA approach. However, the clinical implications are unclear, and larger studies examining patient activity and outcomes are required. Cite this article: Bone Joint J 2020;102-B(12):1654-1661.
Collapse
Affiliation(s)
- Maxwell E Perelgut
- School of Biomedical Engineering, Western University, London, Ontario, Canada.,Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
| | - Jennifer S Polus
- School of Biomedical Engineering, Western University, London, Ontario, Canada.,Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada
| | - Brent A Lanting
- Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
| | - Matthew G Teeter
- School of Biomedical Engineering, Western University, London, Ontario, Canada.,Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.,Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.,Surgical Innovation Program, Lawson Health Research Institute, London, Ontario, Canada
| |
Collapse
|
27
|
Reorienting the tibial baseplate improves the registration accuracy of model-based radiostereometric analysis. J Biomech 2020; 113:110078. [DOI: 10.1016/j.jbiomech.2020.110078] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 10/04/2020] [Accepted: 10/16/2020] [Indexed: 11/19/2022]
|
28
|
Gosling OB, Ferreri TG, Khoshbin A, Whitehouse MR, Atrey A. A systematic review and meta-analysis of survivorship and wear rates of metal and ceramic heads articulating with polyethylene liners in total hip arthroplasty. Hip Int 2020; 30:761-774. [PMID: 32933331 DOI: 10.1177/1120700019866428] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The major joint registries report better survivorship for ceramic on polyethylene over metal on polyethylene bearings in total hip arthroplasty and it is generally accepted that this is due to a lower polyethylene wear rate. We used evidence synthesis to compare survivorship, polyethylene wear rates and metal ion levels for metal-on-polyethylene (MoP) and ceramic-on-polyethylene (CoP) bearings. If wear rates are not dissimilar in vivo this difference in revision rate may have another cause. Modular junctions are a potential source of corrosion and it is postulated that this may result in higher revision rates. METHODS We performed a systematic review and meta-analysis comparing the survivorship of MoP and CoP bearings. Odds ratio (95% CI) of revision was calculated. Mean difference (MD) and 95% confidence intervals (CI) were used to compare secondary outcomes of polyethylene wear and metal ion levels. Meta-analysis was performed with a Mantel-Haenszel Random-Effects Model. RESULTS 6 randomised controlled trials were included. There was no statistically significant difference between MoP and CoP revision rate (OR 1.04; 95% CI, 0.37-2.90, I2 = 0%, p = 0.94), linear bearing wear (MD 0.00 mm; 95% CI, -0.05 -0.05, I2 = 98%, p = 0.90), nor volumetric bearing wear (MD 33.57 mm3; 95% CI, -215.56-282.70, I2 = 98%, p = 0.79). No studies evaluated metal ion levels. CONCLUSIONS We found no evidence of a difference in revision rates nor linear and volumetric wear between MoP and CoP bearings in the randomised controlled trials currently available. Our study therefore does not advocate the additional cost associated with the use of ceramic heads in combination with polyethylene bearings in order to minimise revision rates. This contrasts the findings of in vitro studies and the major joint registries.
Collapse
Affiliation(s)
- Oliver B Gosling
- Avon Orthopaedic Centre, Brunel Building, Southmead Hospital, North Bristol NHS Trust, Bristol, UK
| | - Thomas G Ferreri
- Department of Emergency Medicine, Central Michigan University College of Medicine, MI, USA
| | - Amir Khoshbin
- St Michaels Hospital, Toronto, Canada.,Faculty of Surgery, University of Toronto, Canada
| | - Michael R Whitehouse
- Avon Orthopaedic Centre, Brunel Building, Southmead Hospital, North Bristol NHS Trust, Bristol, UK.,Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, School of Clinical Sciences, Southmead Hospital, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, UK
| | - Amit Atrey
- St Michaels Hospital, Toronto, Canada.,Faculty of Surgery, University of Toronto, Canada
| |
Collapse
|
29
|
[Early assessment of the risk of later implantloosening using Roentgen Sterophotogrammetric Analysis (RSA)]. DER ORTHOPADE 2020; 49:1042-1048. [PMID: 33108489 DOI: 10.1007/s00132-020-04027-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND Aseptic implant loosening is the most common cause of implant revisions in total hip and total knee arthroplasty. Roentgen Stereophotogrammetric Analysis (RSA) represents the current gold standard for the in-vivo assessment of implant fixation. PRESENT SITUATION Long-term clinical trials have shown that continuous implant migration within the first two postoperative years correlates strongly with a later aseptic loosening. Thus, the implant migration measured with RSA can be regarded as a reliable surrogate marker for later implant loosening. Over the past 40 years, RSA has been continuously further developed, and the model-based RSA approach has reduced the effort involved since markers attached to implant are no longer needed. PERSPECTIVES The RSA method is gaining importance in the certification process of new orthopaedic implants-for example, the Dutch Orthopedic Society has recommended phased-introduction and RSA studies for new hip implants. Furthermore, in the context of the new EU Medical Device Regulation (MDR), which took effect in May 2017, RSA gained relevance for investigating clinically unproven implants. Critics who associate MDR with hindering innovation can be countered in that the RSA method provides a predictive assessment of implant fixation after only two years of follow-up, which is significantly shorter than standard long-term clinical trials.
Collapse
|
30
|
Nyring MRK, Olsen BS, Yilmaz M, Petersen MM, Flivik G, Rasmussen JV. Early migration of stemless and stemmed humeral components after total shoulder arthroplasty for osteoarthritis-study protocol for a randomized controlled trial. Trials 2020; 21:830. [PMID: 33028390 PMCID: PMC7541322 DOI: 10.1186/s13063-020-04763-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Accepted: 09/22/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Glenohumeral osteoarthritis can, in the most severe cases, require surgery with insertion of a shoulder arthroplasty. A design with a stem in the humeral bone canal is currently regarded as the standard treatment option in patients who have an intact rotator cuff function, but complications related to the stem including humeral fractures can have devastating consequences. By using a stemless humeral component, stem-related complications can be reduced. The aim of this study is to compare the Comprehensive Nano stemless total shoulder arthroplasty (intervention group) with the Comprehensive stemmed total shoulder arthroplasty (control group). MATERIALS AND METHODS This is a randomized controlled trial comparing the stemless and the stemmed total shoulder arthroplasty. All Danish citizens with glenohumeral osteoarthritis indicating a total shoulder arthroplasty referred to the orthopedic department at Copenhagen University Hospital in Herlev/Gentofte will be offered participation. The following exclude from participation: below 18 years of age, cognitive or linguistic impairment, insufficient function of the rotator cuff, poor bone quality, and ASA groups 4-5. A total of 122 patients will be included of which 56 will be part of a radiostereometric analysis (RSA) study of humeral component migration. The primary outcomes are magnitude of migration of the humeral component assessed by RSA and patient-reported outcome by Western Ontario Osteoarthritis of the Shoulder index (WOOS). The secondary outcomes are additional patient-reported outcomes, functional outcome, readmission, complications, revisions, and changes in bone mineral density (BMD) of the proximal humerus assessed by duel energy x-ray absorptiometry (DXA) and economy (cost-utility analysis). The patients are examined before the operation and 3, 6, 12, and 24 months postoperative. DISCUSSION To our knowledge, RSA has never been used to access migration of a stemmed or a stemless humeral component nor has the stemmed and the stemless humeral component been compared with regard to pain relief and shoulder function in a randomized clinical trial. Today, the two designs are considered equal in the treatment of osteoarthritis. The study will provide surgeons and patients with information about shoulder arthroplasty for osteoarthritis and assist them in decision-making. TRIAL REGISTRATION ClinicalTrials.gov NCT04105478 . Registered on 25 September 2019.
Collapse
Affiliation(s)
- Marc Randall Kristensen Nyring
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark.
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark.
| | - Bo S Olsen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Müjgan Yilmaz
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark
| | - Michael M Petersen
- Department of Orthopedic Surgery, Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Gunnar Flivik
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
- Department of Orthopedic Surgery, Skaane University Hospital, Lund, Sweden
| | - Jeppe V Rasmussen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
- Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
31
|
Howie DW, Holubowycz OT, Callary SA, Robertson TS, Solomon LB. Highly Porous Tantalum Acetabular Components Without Ancillary Screws Have Similar Migration to Porous Titanium Acetabular Components With Screws at 2 Years: A Randomized Controlled Trial. J Arthroplasty 2020; 35:2931-2937. [PMID: 32593487 DOI: 10.1016/j.arth.2020.05.049] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 05/17/2020] [Accepted: 05/20/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND It is proposed that highly porous coatings on acetabular components, such as a porous tantalum coating, provide adequate fixation without ancillary screw fixation in primary total hip arthroplasty (THA). However, tantalum acetabular components have been associated with higher rates of revision than other uncemented components in national registries. The aim of this randomized controlled trial is to determine whether the early migration of a solid-backed tantalum acetabular component was no greater than that of a titanium acetabular component with ancillary screw fixation that has proven good clinical results. METHODS Sixty-six patients aged 40 to 64 years, with osteoarthritis and Charnley grade A or B activity grade and who underwent primary THA, were recruited into the trial. Patients were randomized intraoperatively to receive either the tantalum or titanium acetabular component. All patients received the same cemented polished tapered femoral stem, 28-mm cobalt-chromium femoral head, and highly cross-linked polyethylene liner. Acetabular component migration was measured using radiostereometric analysis at 4-6 days postoperatively and at 6 weeks, 3 months, 1 and 2 years following THA. RESULTS The mean proximal migration at 2 years for the tantalum cohort was 0.17 mm (95% confidence interval, 0.09-0.24) which was no greater than that of the titanium cohort which was 0.19 mm (0.07-0.32). Harris hip scores and functional activity scores were similar between groups. CONCLUSION These results demonstrate that early stability can be achieved without ancillary screw fixation through the use of a highly porous high friction coating on a solid-backed modular acetabular component. LEVEL OF EVIDENCE Level I.
Collapse
Affiliation(s)
- Donald W Howie
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia; Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia, Australia
| | - Oksana T Holubowycz
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia, Australia
| | - Stuart A Callary
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia; Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia, Australia
| | - Thomas S Robertson
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia, Australia
| | - Lucian B Solomon
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia; Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia, Australia
| |
Collapse
|
32
|
CORR Insights®: RSA-tested TKA Implants on Average Have Lower Mean 10-year Revision Rates Than Non-RSA-tested Designs. Clin Orthop Relat Res 2020; 478:1242-1243. [PMID: 32332238 PMCID: PMC7319366 DOI: 10.1097/corr.0000000000001269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
33
|
Abrahams JM, Callary SA, Munn Z, Jang SW, Huang Q, Howie DW, Solomon LB. Acetabular Component Migration Measured Using Radiostereometric Analysis Following Revision Total Hip Arthroplasty: A Scoping Review. JBJS Rev 2020; 8:e0170. [PMID: 32304493 DOI: 10.2106/jbjs.rvw.19.00170] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
* Radiostereometric analysis (RSA) studies of acetabular component migration following revision total hip arthroplasty (THA) have a large variation in their methodology and reporting of results, and, therefore, they may not be directly comparable. Standardization of RSA reporting is recommended.
* In our review of RSA studies, there was a trend for cemented acetabular components to have larger amounts of early proximal migration than uncemented acetabular components. Results regarding cemented and uncemented components should be reported separately. * Cohorts that addressed larger acetabular defects were associated with a larger amount of early migration. * Reporting the migration result at 1 and 2 years postoperatively may enable earlier identification of poorly performing implants.
Collapse
Affiliation(s)
- John M Abrahams
- Centre for Orthopaedic and Trauma Research (J.M.A., S.A.C., S.W.J., Q.H., D.W.H., and L.B.S.) and the Joanna Briggs Institute (Z.M.), The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Stuart A Callary
- Centre for Orthopaedic and Trauma Research (J.M.A., S.A.C., S.W.J., Q.H., D.W.H., and L.B.S.) and the Joanna Briggs Institute (Z.M.), The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Zachary Munn
- Centre for Orthopaedic and Trauma Research (J.M.A., S.A.C., S.W.J., Q.H., D.W.H., and L.B.S.) and the Joanna Briggs Institute (Z.M.), The University of Adelaide, Adelaide, South Australia, Australia
| | - Sung Won Jang
- Centre for Orthopaedic and Trauma Research (J.M.A., S.A.C., S.W.J., Q.H., D.W.H., and L.B.S.) and the Joanna Briggs Institute (Z.M.), The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedic Surgery, Pohang SeMyeong Christianity Hospital, Pohang-si, Republic of Korea
| | - Qiang Huang
- Centre for Orthopaedic and Trauma Research (J.M.A., S.A.C., S.W.J., Q.H., D.W.H., and L.B.S.) and the Joanna Briggs Institute (Z.M.), The University of Adelaide, Adelaide, South Australia, Australia.,Orthopedic Department of West China Hospital, Sichuan University, Chengdu City, China
| | - Donald W Howie
- Centre for Orthopaedic and Trauma Research (J.M.A., S.A.C., S.W.J., Q.H., D.W.H., and L.B.S.) and the Joanna Briggs Institute (Z.M.), The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Lucian Bogdan Solomon
- Centre for Orthopaedic and Trauma Research (J.M.A., S.A.C., S.W.J., Q.H., D.W.H., and L.B.S.) and the Joanna Briggs Institute (Z.M.), The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| |
Collapse
|
34
|
New Implant Introduction in Total Hip Arthroplasty Using Radiostereometric Analysis: A Cautionary Note. J Arthroplasty 2020; 35:643-646. [PMID: 31678017 DOI: 10.1016/j.arth.2019.10.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 09/22/2019] [Accepted: 10/03/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND It has been proposed that the introduction of new hip implant technology in orthopedic surgery be conducted in a more controlled manner in order to properly ensure patient safety and the likelihood of favorable outcomes. This stepwise introduction would first require a prospective randomized study in a small cohort of patients, using radiostereometric analysis (RSA). The aim of this study is to determine if the recent literature supports the use of RSA as an early screening tool to accurately predict the long-term outcomes of cementless femoral stems. METHODS A review of the recent published literature identified 11 studies that used RSA to predict the long-term stability of a cementless femoral component. These RSA predictive data were compared to the 10-year revision rate reported in the Australian Registry or in the published literature to determine its reliability. RESULTS RSA data did not universally predict long-term stem fixation. In 2 of the 11 cases (18%), the RSA study incorrectly predicted the ability of the cementless stem to reliably osseointegrate. Of the 9 stems considered stable in the RSA studies, the 10 year registry and literature data confirmed that 6 implants had a low revision rate and were well performing. One stem has not performed well clinically and has been listed as having a higher than anticipated rate of revision in the registry. Two stems do not have sufficient follow-up. Of the 2 stems RSA predicted to do poorly, 1 is well performing at 10 years, and 1 has a high revision rate at 8 years. CONCLUSION In the stepwise introduction of new hip implants, RSA should be best considered as an adjunct tool in deciding whether or not an implant should be evaluated in a larger multicenter clinical studies, rather than the sole criterion.
Collapse
|
35
|
Lindgren L, Jørgensen PB, Mørup RMS, Jensen M, Rømer L, Kaptein B, Stilling M. Similar patient positioning: A key factor in follow-up studies when using model-based radiostereometric analysis of the hip. Radiography (Lond) 2020; 26:e45-e51. [PMID: 32052775 DOI: 10.1016/j.radi.2019.10.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 08/30/2019] [Accepted: 10/22/2019] [Indexed: 01/28/2023]
Abstract
INTRODUCTION Despite protocols, patients are not positioned exactly alike at radiostereometric (RSA) follow-up examinations, and it is unknown how much variation is tolerable. We report precision for optimal and extreme position differences from a phantom hip-study, and clinical precision of hip-RSA. METHODS A femoral stem with 3 bead-towers was fixed in a saw bone with bone-markers (phantom), and series of RSA examinations within optimal (5 × 5 cm and 5°) and extreme (20 × 30 cm and 30°) phantom positions were obtained. Double-examination RSA of 12 patients with the same femoral stem type were analyzed. Both model-based (CAD) and marker-based (MM) analysis was used. Precision was reported as standard deviation of differences. RESULTS Precision for translations in the optimal and extreme phantom position were below 0.06 mm and 0.02 mm for MM analysis, and below 0.05 mm and 0.18 mm for CAD analysis, respectively. Precision for rotations in the optimal and extreme phantom rotation were below 0.18° and 0.26° for MM analysis, and below 0.34° and 0.52° for CAD analysis, respectively. Clinical precision was 0.29 mm and 0.44° for MM analysis, and 0.40 mm and 1.59° for CAD analysis. CONCLUSION Extreme differences in patient position during RSA examination negatively affects precision, and CAD model-analysis was more sensitive than MM analysis. Longitudinal translation and rotation about the long stem-axis are the effect parameters which are most affected by position and rotation changes, and also the best indicators of implant loosening. IMPLICATIONS FOR PRACTICE Based on our research, we recommend that similar patient positioning between follow-up RSA examinations is debated and prioritized.
Collapse
Affiliation(s)
- L Lindgren
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - P B Jørgensen
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - R M S Mørup
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - M Jensen
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - L Rømer
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| | - B Kaptein
- Biomechanics and Imaging Group (BIG), Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, the Netherlands.
| | - M Stilling
- Orthopedic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark.
| |
Collapse
|
36
|
Radiostereometric Analysis of Stability and Inducible Micromotion After Locked Lateral Plating of Distal Femur Fractures. J Orthop Trauma 2020; 34:e60-e66. [PMID: 31794438 DOI: 10.1097/bot.0000000000001684] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES To evaluate interfragmentary motion over 1 year after distal femoral fracture fixation using radiostereometric analysis (RSA). The secondary aim was to assess whether RSA data are consistent with diagnoses of nonunion. DESIGN Prospective cohort study. SETTING Level I urban trauma center. PATIENTS Sixteen patients between 22 and 89 years of age with distal femoral fracture (OTA/AO type 33). INTERVENTION All fractures were treated with a lateral locking plate, and tantalum markers were inserted into the main proximal and distal fracture fragments. RSA was performed at 2, 6, 12, 18, and 52 weeks postoperatively. Both unloaded and loaded RSA measurements were performed. MAIN OUTCOME MEASUREMENTS Unloaded fracture migration over time and inducible micromotion at the fracture site in the coronal plane were determined at each follow-up interval. RESULTS RSA precision in the coronal plane of interfragmentary motion over time and inducible micromotion were 1.2 and 0.9 mm in the coronal plane, respectively. Two cases required revision surgery for nonunion 1 year postoperatively. For cases of union, unloaded fracture migration stopped being detectable between 12 and 18 weeks, and inducible micromotion was no longer detectable by the 12-week visit. For cases of nonunion, both unloaded migration and inducible micromotion were detected throughout the study period. CONCLUSIONS RSA may be used to reliably assess distal femoral fracture healing. RSA revealed differences in cases of union and nonunion by 3 months and more consistently than traditional x-rays. LEVEL OF EVIDENCE Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
37
|
Gascoyne T, Parashin S, Teeter M, Bohm E, Laende E, Dunbar M, Turgeon T. In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis. Bone Joint J 2019; 101-B:1348-1355. [DOI: 10.1302/0301-620x.101b11.bjj-2018-1447.r2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). Patients and Methods Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. Results Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm3/year (supine) and 39.3 mm3/year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of measurement. Clinical precision of volumetric wear was 34 mm3. No significant associations were found between patient demographics or function scores and measured wear. Conclusion In vivo volumetric wear of TKAs can be assessed at short-term follow-up using MBRSA. Cite this article: Bone Joint J 2019;101-B:1348–1355.
Collapse
Affiliation(s)
- Trevor Gascoyne
- Orthopaedic Innovation Centre, Winnipeg, Canada
- Concordia Joint Replacement Group, Winnipeg, Canada
| | | | - Matthew Teeter
- London Health Sciences Centre, Western University, London, Canada
| | - Eric Bohm
- Orthopaedic Innovation Centre, Winnipeg, Canada
- Concordia Joint Replacement Group, Winnipeg, Canada
- University of Manitoba, Winnipeg, Canada
| | - Elise Laende
- QEII Health Sciences Centre, Dalhousie University and Nova Scotia Health Authority, Halifax, Canada
| | - Michael Dunbar
- QEII Health Sciences Centre, Dalhousie University and Nova Scotia Health Authority, Halifax, Canada
| | - Thomas Turgeon
- Concordia Joint Replacement Group, Winnipeg, Canada
- University of Manitoba, Winnipeg, Canada
| |
Collapse
|
38
|
Does migration of osseointegrated implants for transfemoral amputees predict later revision? A prospective 2-year radiostereometric analysis with 5-years clinical follow-up. Orthop Traumatol Surg Res 2019; 105:1013-1020. [PMID: 31255502 DOI: 10.1016/j.otsr.2019.05.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 05/14/2019] [Accepted: 05/27/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND The osseointegrated (OI) prosthesis is a treatment option for transfemoral amputees with a short residual femur and/or difficulties caused by using the prosthetic socket. Implant removal due to aseptic or septic loosening is not uncommon, but the association between implant migration patterns and the need for removal has not previously been studied. We conducted a prospective model-based radiostereometric analysis study to investigate: if the OI implant migration pattern 1) differs between later removed implants and non-removed implants, (2) predicts later implant removal, and (3) if the precision of the method is acceptable. HYPOTHESIS Model-based radiostereometric analysis of the OI implant migration pattern can be used to predict later OI implant removal. MATERIAL AND METHODS A prospective cohort of 17 consecutive transfemoral amputees suitable for surgery (11 males), mean age 50 (range 32-66) were treated with an OI implant (Integrum AB, Sweden). Postoperative stereoradiographs of the OI implant were obtained during 24-month follow-up. X, Y, and Z translations and total translations were evaluated using CAD-implant models. Implant survival was followed for up to 60 months. RESULTS Six total implant removals (fixture and abutment) and four partial removals (abutment) were conducted (10/17 (59%)), and one patient did not use the OI implant. The removed implants group migrated a mean (±standard deviation) 0.55mm±0.75mm (p=0.009) and the non-removed implants group migrated 0.31mm±0.51mm (p=0.22) in total translations from 3 months to last follow-up. Odds ratio for implant removal was 22.5 (95% CI: 1.6 to 314 (p=0.021)) if the OI implants migrated distally. CONCLUSION Later removed OI implants migrated from 3 months to last follow-up and more than the non-removed OI implants. Distal implant migration greatly increased the odds of implant removal. Ten out of 17 OI implants were removed within 5 years of follow-up. We advise to use OI implants with caution and close follow-up in consideration of the risk of complications. LEVEL OF EVIDENCE IV, Prospective study.
Collapse
|
39
|
Jacobsen A, Seehaus F, Hong Y, Cao H, Schuh A, Forst R, Sesselmann S. Model-based roentgen stereophotogrammetric analysis using elementary geometrical shape models: 10 years results of an uncemented acetabular cup component. BMC Musculoskelet Disord 2018; 19:335. [PMID: 30223820 PMCID: PMC6142331 DOI: 10.1186/s12891-018-2259-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 09/12/2018] [Indexed: 11/16/2022] Open
Abstract
Background Non-cemented acetabular cup components demonstrated different clinical performance depending on their surface texture or bearing couple. However, clinical osseointegration needs to be proved for each total joint arthroplasty (TJA) design. Aim of this study was to detect the in vivo migration pattern of a non-cemented cup design, using model-based roentgen stereophotogrammetric analysis with elementary geometrical shape models (EGS-RSA) to calculate early cup migration. Methods Interchangeable applicability of the model-based EGS-RSA method next to gold standard marker-based RSA method was assessed by clinical radiographs. Afterwards, in vivo acetabular cup migration for 39 patients in a maximum follow up of 120 months (10 years) was calculated using model-based EGS-RSA. Results For the axes with the best predictive capability for acetabular cup loosening, mean (±SD) values were calculated for migration and rotation of the cup. The cup migrated 0.16 (±0.22) mm along the cranio-caudal axis after 24 months and 0.36 (±0.72) mm after 120 months, respectively. It rotated − 0.61 (±0.57) deg. about the medio-lateral axis after 24 months and − 0.53 (±0.67) deg. after 120 months, respectively. Conclusions Interchangeable applicability of model-based EGS-RSA next to gold standard marker-based RSA method could be shown. Model-based EGS-RSA enables an in vivo migration measurement without the necessity of TJA specific surface models. Migration of the investigated acetabular cup component indicates significant migration values along all the three axes. However, migration values after the second postoperative year were within the thresholds reported in literature, indicating no risk for later aseptic component loosening of this TJA design.
Collapse
Affiliation(s)
- Anne Jacobsen
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Rathsberger Str. 57, 91054, Erlangen, Germany
| | - Frank Seehaus
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Rathsberger Str. 57, 91054, Erlangen, Germany
| | - Yutong Hong
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Rathsberger Str. 57, 91054, Erlangen, Germany
| | - Han Cao
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Rathsberger Str. 57, 91054, Erlangen, Germany
| | - Alexander Schuh
- Muskuloskelettales Zentrum, Klinikum Neumarkt, Nürnberger Str. 12, 92318, Neumarkt i. d. OPf, Germany
| | - Raimund Forst
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Rathsberger Str. 57, 91054, Erlangen, Germany
| | - Stefan Sesselmann
- Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Rathsberger Str. 57, 91054, Erlangen, Germany. .,Institute for Medical Technology, Ostbayerische Technische Hochschule Amberg-Weiden, Hetzenrichter Weg 15, 92637, Weiden, Germany.
| |
Collapse
|
40
|
Muharemovic O, Troelsen A, Thomsen MG, Kallemose T, Gosvig KK. A pilot study to determine the effect of radiographer training on radiostereometric analysis imaging technique. Radiography (Lond) 2018; 24:e37-e43. [PMID: 29605123 DOI: 10.1016/j.radi.2017.12.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 11/21/2017] [Accepted: 12/02/2017] [Indexed: 01/06/2023]
Abstract
INTRODUCTION Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers in acquiring images of an optimal quality. METHODS A controlled trial using action research strategy was used. The study entailed a two phased approach. Radiographers were purposefully recruited and trained to perform the required investigations. Each phase included 12 examinations of a total knee arthroplasty phantom followed by 10 patient examinations. The quality of all x-ray images performed during the two phases was characterized by measuring the number of visible beads, the center position of the prosthesis (CP) compared to the center of calibration field (CCF). The number of re-exposures used to obtain a usable image during patient examinations was also recorded. RESULTS The radiographers undergoing the training resulted in a significant improvement in the quality of images produced and visualization of the beads. That is, the ability to move the CP on average 36.1 mm closer to the CCF (p < 0.001), the number of visible beads increased by 3.1 (p < 0.001) and radiographers needed 2.1-2.9 exposures less to obtain RSA images of sufficient qualities during patient examinations in phase 2 (p < 0.001). CONCLUSION This study illustrates the value of experiential method of teaching and learning with minimal compromise on patient safety but a significant contribution in terms of establishing quality of RSA images.
Collapse
Affiliation(s)
- O Muharemovic
- Department of Radiology, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| | - A Troelsen
- Department of Orthopaedic Surgery, Clinical Orthopedic Research Hvidovre, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| | - M G Thomsen
- Department of Orthopaedic Surgery, Clinical Orthopedic Research Hvidovre, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| | - T Kallemose
- Department of Orthopaedic Surgery, Clinical Orthopedic Research Hvidovre, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark; Clinical Research Center, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| | - K K Gosvig
- Department of Radiology, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| |
Collapse
|
41
|
Van de Kleut ML, Yuan X, Athwal GS, Teeter MG. Validation of radiostereometric analysis in six degrees of freedom for use with reverse total shoulder arthroplasty. J Biomech 2018; 68:126-131. [DOI: 10.1016/j.jbiomech.2017.12.027] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 12/11/2017] [Accepted: 12/17/2017] [Indexed: 11/15/2022]
|
42
|
Schröder FF, Verdonschot NJJ, Ten Haken B, Peters A, Vochteloo AJH, Pakvis DFM, Huis In't Veld R. Low-field magnetic resonance imaging offers potential for measuring tibial component migration. J Exp Orthop 2018; 5:4. [PMID: 29330713 PMCID: PMC5766455 DOI: 10.1186/s40634-017-0116-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 12/20/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Roentgen stereophotogrammetric analysis (RSA) is used to measure early prosthetic migration and to predict future implant failure. RSA has several disadvantages, such as the need for perioperatively inserted tantalum markers. Therefore, this study evaluates low-field MRI as an alternative to RSA. The use of traditional MRI with prostheses induces disturbing metal artifacts which are reduced by low-field MRI. The purpose of this study is to assess the feasibility to use low-field (0.25 Tesla) MRI for measuring the precision of zero motion. This was assessed by calculating the virtual prosthetic motion of a zero-motion prosthetic reconstruction in multiple scanning sessions. Furthermore, the effects of different registration methods on these virtual motions were tested. RESULTS The precision of zero motion for low-field MRI was between 0.584 mm and 1.974 mm for translation and 0.884° and 3.774° for rotation. The manual registration method seemed most accurate, with μ ≤ 0.13 mm (σ ≤ 0.931 mm) for translation and μ ≤ 0.15° (σ ≤ 1.63°) for rotation. CONCLUSION Low-field MRI is not yet as precise as today's golden standard (marker based RSA) as reported in the literature. However, low-field MRI is feasible of measuring the relative position of bone and implant with comparable precision as obtained with marker-free RSA techniques. Of the three registration methods tested, manual registration was most accurate. Before starting clinical validation further research is necessary and should focus on improving scan sequences and registration algorithms.
Collapse
Affiliation(s)
- F F Schröder
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands. .,MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands.
| | - N J J Verdonschot
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands.,Radboud Institute for Health Sciences, Orthopaedic Research Lab, Radboud university medical center, Nijmegen, The Netherlands
| | - B Ten Haken
- MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - A Peters
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands
| | - A J H Vochteloo
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands
| | - D F M Pakvis
- Centre for Orthopaedic Surgery OCON, Hengelo, The Netherlands
| | | |
Collapse
|
43
|
Early acetabular cartilage wear following hemiarthroplasty: An ovine model. Vet Comp Orthop Traumatol 2017; 29:125-30. [DOI: 10.3415/vcot-15-04-0063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Accepted: 10/18/2015] [Indexed: 11/17/2022]
Abstract
SummaryObjectives: Hemiarthroplasty induces degenerative changes in the hip joint, which are difficult to evaluate in vivo. Radiostereometric analysis (RSA) is a radiographic measurement technique that has recently been used to measure acetabular cartilage wear in vivo. The aim of the study was to measure acetabular cartilage wear, using this technique, in an ovine model during the first 14 weeks post-implantation.Methods: Measurements of three-dimensional femoral head migration, combined with visual assessments at necropsy and safranin O staining for cartilage integrity, were undertaken.Results: Mean femoral head migration during the first six weeks was 0.525 mm in the medial, 0.144 mm in the cranial, and 0.517 mm in the dorsal direction. The majority of this migration was confirmed to be cartilage wear in the medial and dorsal aspects of the acetabulum at necropsy and with subsequent histological evaluation depicting significant cartilage degeneration.Clinical significance: Radiostereometric analysis is the current gold standard technique for in vivo assessment of implant migration following total hip replacement. This study has utilized RSA to quantify the amount of early cartilage wear in vivo, which was supported by ex vivo evaluations. Accurately measuring the amount of cartilage wear will allow future studies to compare component material and design characteristics prior to clinical use.
Collapse
|
44
|
Abstract
STUDY DESIGN Systematic review of literature. OBJECTIVES This systematic review was conducted to investigate the accuracy of radiostereometric analysis (RSA), its assessment of spinal motion and disorders, and to investigate the limitations of this technique in spine assessment. METHODS Systematic review in all current literature to invesigate the role of RSA in spine. RESULTS The results of this review concluded that RSA is a very powerful tool to detect small changes between 2 rigid bodies such as a vertebral segment. The technique is described for animal and human studies for cervical and lumbar spine and can be used to analyze range of motion, inducible displacement, and fusion of segments. However, there are a few disadvantages with the technique; RSA percutaneous procedure needs to be performed to implant the markers (and cannot be used preoperatively), one needs a specific knowledge to handle data and interpret the results, and is relatively time consuming and expensive. CONCLUSIONS RSA should be looked at as a very powerful research instrument and there are many questions suitable for RSA studies.
Collapse
Affiliation(s)
- Ali Humadi
- The Alfred Hospital, Melbourne, Victoria, Australia,Ali Humadi, Department of Orthopaedics and Trauma, The Alfred Hospital, 55 Commercial Road, Melbourne, Victoria 3004, Australia.
| | - Sulaf Dawood
- The Alfred Hospital, Melbourne, Victoria, Australia,Ali Humadi, Department of Orthopaedics and Trauma, The Alfred Hospital, 55 Commercial Road, Melbourne, Victoria 3004, Australia.
| | - Klas Halldin
- Sahlgrenska University Hospital, Gothenburg, Sweden,Ali Humadi, Department of Orthopaedics and Trauma, The Alfred Hospital, 55 Commercial Road, Melbourne, Victoria 3004, Australia.
| | - Brian Freeman
- Royal Adelaide Hospital, Adelaide, SA, Australia,Ali Humadi, Department of Orthopaedics and Trauma, The Alfred Hospital, 55 Commercial Road, Melbourne, Victoria 3004, Australia.
| |
Collapse
|
45
|
Hannan R, Arora V, Beaver R, Harvie P. How should new orthopaedic implants be introduced: an example and recommendations for best practice. ANZ J Surg 2017; 88:284-289. [PMID: 29124832 DOI: 10.1111/ans.14234] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2017] [Revised: 07/14/2017] [Accepted: 08/14/2017] [Indexed: 10/18/2022]
Abstract
Continued advancements in orthopaedics have led to the development of many new implants; many of these are being utilized in clinical practice with little or no evidence base for their safety or effectiveness. Highly publicized failures in orthopaedic technology have led to an increased awareness of this issue in both medical and non-medical circles. In most cases, the significant harm caused to the public could have been avoided by the appropriately staged implementation of new implants. This review comments on the current literature regarding the optimal practice for the introduction of new orthopaedic technology. The authors' experience with the failed ESKA Adapter Short-stem/Modular Hip is described; the methodology used for its evaluation is used as a basis to discuss what was successful about the process and also give warning on what could be improved upon. The ideal practice requires new orthopaedic implants to be evaluated by high-volume surgeons in specialist orthopaedic hospitals. These studies should include biomechanical studies, radiostereophotometric analysis, implant retrieval and outcome assessment. Results and complications should be reported early to the appropriate joint registry and regulatory body. Once a suitable evidence base has developed, the implant can be distributed into wider clinical practice or withdrawn. These recommendations aim to protect the patient and public from harm while allowing surgical innovation to still continue.
Collapse
Affiliation(s)
- Richard Hannan
- Department of Orthopaedics, Royal Hobart Hospital, Hobart, Tasmania, Australia
| | - Varun Arora
- Department of Orthopaedics, Royal Hobart Hospital, Hobart, Tasmania, Australia
| | - Richard Beaver
- Department of Orthopaedics, Royal Perth Hospital, Perth, Western Australia, Australia
| | - Paul Harvie
- Department of Orthopaedics, Royal Hobart Hospital, Hobart, Tasmania, Australia
| |
Collapse
|
46
|
Equal Primary Fixation of Resurfacing Stem, but Inferior Cup Fixation With Anterolateral vs Posterior Surgical Approach. A 2-Year Blinded Randomized Radiostereometric and Dual-energy X-Ray Absorptiometry Study of Metal-on-Metal Hip Resurfacing Arthroplasty. J Arthroplasty 2017. [PMID: 28641972 DOI: 10.1016/j.arth.2017.05.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND The anterolateral (AntLat) surgical approach may spare the blood supply to the femoral head and improve the accuracy of cup positioning in metal-on-metal hip resurfacing arthroplasty. Thereby, potentially lessen complications such as avascular head necrosis, femoral neck narrowing and fracture, improve implant fixation, and lessen periprosthetic bone mineral density (BMD) loss. METHODS Between November 2008 and January 2012, a randomized clinical trial was performed at Aarhus University Hospital. A total of 49 patients (28 males) were allocated to metal-on-metal hip resurfacing arthroplasty by the AntLat (n = 25) or the posterior (Post; n = 24) surgical approach. Patients were followed with radiostereometric analysis, measurements of periprosthetic BMD, clinical outcome scores of Harris hip score and visual analogue scale, serum metal ions, and conventional radiographs. RESULTS At 3 months, cups in the AntLat group had higher total translations of mean 1.00 ± 0.70 mm vs mean 0.64 ± 0.45 mm in the post group (P = .04), and higher total rotations of mean 2.44° ± 1.36° vs mean 1.39° ± 1.17° in the Post group (P = .002). All migrations of cup and stem were similar at 1 and 2 years postoperative (P > .07). At 1 year, periprosthetic BMD since postoperative at the medial side of the stem was reduced to mean 98.45% ± 8.57% in the AntLat group, and increased to mean 105.57% ± 11.07% in the Post group (P = .02), but measurements were comparable at 2 years (P = .05). CONCLUSION Cups inserted by the AntLat approach migrated more until 3 months postoperative. This illustrates a less good primary cup fixation with the AntLat approach; however, all cups were well-fixed after 3 months' follow-up indicating a good secondary fixation.
Collapse
|
47
|
Horsager K, Kaptein BL, Rømer L, Jørgensen PB, Stilling M. Dynamic RSA for the evaluation of inducible micromotion of Oxford UKA during step-up and step-down motion. Acta Orthop 2017; 88:275-281. [PMID: 28067099 PMCID: PMC5434595 DOI: 10.1080/17453674.2016.1274592] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Implant inducible micromotions have been suggested to reflect the quality of the fixation interface. We investigated the usability of dynamic RSA for evaluation of inducible micromotions of the Oxford Unicompartmental Knee Arthroplasty (UKA) tibial component, and evaluated factors that have been suggested to compromise the fixation, such as fixation method, component alignment, and radiolucent lines (RLLs). Patients and methods - 15 patients (12 men) with a mean age of 69 (55-86) years, with an Oxford UKA (7 cemented), were studied after a mean time in situ of 4.4 (3.6-5.1) years. 4 had tibial RLLs. Each patient was recorded with dynamic RSA (10 frames/second) during a step-up/step-down motion. Inducible micromotions were calculated for the tibial component with respect to the tibia bone. Postoperative component alignment was measured with model-based RSA and RLLs were measured on screened radiographs. Results - All tibial components showed inducible micromotions as a function of the step-cycle motion with a mean subsidence of up to -0.06 mm (95% CI: -0.10 to -0.03). Tibial component inducible micromotions were similar for cemented fixation and cementless fixation. Patients with tibial RLLs had 0.5° (95% CI: 0.18-0.81) greater inducible medio-lateral tilt of the tibial component. There was a correlation between postoperative posterior slope of the tibial plateau and inducible anterior-posterior tilt. Interpretation - All patients had inducible micromotions of the tibial component during step-cycle motion. RLLs and a high posterior slope increased the magnitude of inducible micromotions. This suggests that dynamic RSA is a valuable clinical tool for the evaluation of functional implant fixation.
Collapse
Affiliation(s)
- Kristian Horsager
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark;,Correspondence:
| | - Bart L Kaptein
- Department of Orthopedic Surgery, Biomechanics and Imaging Group, Leiden University Medical Center, Leiden, the Netherlands
| | - Lone Rømer
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Peter B Jørgensen
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
48
|
Hjorth MH, Kold S, Søballe K, Langdahl BL, Nielsen PT, Christensen PH, Stilling M. Preparation of the Femoral Bone Cavity for Cementless Stems: Broaching vs Compaction. A Five-Year Randomized Radiostereometric Analysis and Dual Energy X-Ray Absorption Study. J Arthroplasty 2017; 32:1894-1901. [PMID: 28111123 DOI: 10.1016/j.arth.2016.12.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Revised: 11/24/2016] [Accepted: 12/17/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Short-term experimental and animal studies have confirmed superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. METHODS Forty-four hips in 42 patients (19 men) were randomly operated using cementless hydroxyapatite-coated Bi-Metric stems. Patients were followed with radiostereometric analysis at baseline, 6 and 12 weeks, 1, 2, and 5 years, and measurements of periprosthetic bone mineral density at baseline, 1, 2, and 5 years. Complications during the study period and clinical outcome measures of Harris Hip Score were recorded at mean 7 years (5-8.8) after surgery. RESULTS Absolute migrations of medio/lateral translations between the broaching group and the compaction group of mean 0.14 mm (standard deviation [SD] 0.10) vs mean 0.30 mm (SD 0.27) (P = .01) at 1 year, and of mean 0.13 mm (SD 0.10) vs 0.34 mm (0.31) (P = .01) at 5 years were different. Absolute valgus/varus rotations of mean 0.12° (SD 0.13°) in the broaching group were less than mean 0.35° (0.45°) in the compaction group (P < .01) at 1 year, but at 5 years no difference was observed (P = .19). Subsidence and retroversion were similar between groups at all follow-ups (P > .13). The compaction group had significantly less bone loss than the broaching group in Gruen zone 3 (distal-lateral to the stem) at 1 and 5 years. No further differences in bone mineral density changes were found between groups up to 5 years after surgery. Complications throughout the period and clinical outcome measures of Harris Hip Score were similar at 7 years (5-8.8) after surgery. CONCLUSION We found increased migration when preparing the bone with compaction compared with broaching in cementless femoral stems.
Collapse
Affiliation(s)
- Mette H Hjorth
- Department of Orthopaedics, THG, Aarhus University Hospital, Aarhus, Denmark
| | - Søren Kold
- Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
| | - Kjeld Søballe
- Department of Orthopaedics, THG, Aarhus University Hospital, Aarhus, Denmark
| | - Bente L Langdahl
- Department of Endocrinology and Internal Medicine, THG, Aarhus University Hospital, Aarhus, Denmark
| | - Poul T Nielsen
- Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
| | - Poul H Christensen
- Department of Orthopaedics, Aalborg University Hospital, Aalborg, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, THG, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
49
|
Wall PDH, Richards BL, Sprowson A, Buchbinder R, Singh JA. Do outcomes reported in randomised controlled trials of joint replacement surgery fulfil the OMERACT 2.0 Filter? A review of the 2008 and 2013 literature. Syst Rev 2017; 6:106. [PMID: 28558822 PMCID: PMC5450048 DOI: 10.1186/s13643-017-0498-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Accepted: 05/10/2017] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND It is not known, whether outcome reporting in trials of total joint arthroplasty in the recent years is adequate or not. Our objective was to assess whether outcomes reported in total joint replacement (TJR) trials fulfil the Outcome Measures in Rheumatology (OMERACT) Filter 2.0. METHODS We systematically reviewed all TJR trials in adults, published in English in 2008 or 2013. Searches were conducted in the Cochrane Central Register of Controlled Trials, MEDLINE, and EMBASE. Two authors independently applied the inclusion criteria for the studies, and any disagreement was resolved with a third review author. All outcome measures were abstracted using a pre-piloted standardised data extraction form and assessed for whether they mapped to one of the three OMERACT Filter 2.0 core areas: pathophysiological, life impact, and death. RESULTS From 1635 trials identified, we included 70 trials (30 in 2008 and 40 in 2013) meeting the eligibility criteria. Twenty-two (31%) trials reported the three essential OMERACT core areas. Among the 27 hip replacement surgery trials and 39 knee replacement surgery trials included, 11 hip (41%) and nine knee (23%) trials reported all three essential OMERACT core areas. The most common outcome domains/measures were pain (20/27, 74%) and function (23/27, 85%) in hip trials and pain (26/39, 67%) and function (27/39, 69%) in knee trials. Results were similar for shoulder and hand joint replacement trials. CONCLUSIONS We identified significant gaps in the measurement of OMERACT core outcome areas in TJR trials, despite the majority reporting outcome domains of pain and function. An international consensus of key stakeholders is needed to develop a core domain set for reporting of TJR trials. SYSTEMATIC REVIEW REGISTRATION PROSPERO CRD42014009216.
Collapse
Affiliation(s)
- Peter D H Wall
- Warwick Clinical Trials Unit, University of Warwick, Coventry, UK
| | - Bethan L Richards
- Institute of Rheumatology and Orthopaedics, Royal Prince Alfred Hospital, Sydney, Australia.,Sydney Medical School, University of Sydney, Sydney, Australia
| | - Andrew Sprowson
- Warwick Clinical Trials Unit, University of Warwick, Coventry, UK
| | - Rachelle Buchbinder
- Department of Epidemiology and Preventive Medicine, School of Public Health & Preventive Medicine, Monash University, Frankston, VIC, Australia.,Monash Department of Clinical Epidemiology, Cabrini Institute, Melbourne, VIC, Australia
| | - Jasvinder A Singh
- Birmingham Veterans Affairs Medical Center and University of Alabama at Birmingham, Faculty Office Tower 805B, 510 20th Street S, Birmingham, AL, 35294, USA. .,Mayo Clinic School of Medicine, Rochester, MN, USA.
| |
Collapse
|
50
|
Callary SA, Solomon LB, Holubowycz OT, Campbell DG, Howie DW. Accuracy of methods to measure femoral head penetration within metal-backed acetabular components. J Orthop Res 2017; 35:988-996. [PMID: 27357247 DOI: 10.1002/jor.23356] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Accepted: 06/22/2016] [Indexed: 02/04/2023]
Abstract
A number of different software programs are used to investigate the in vivo wear of polyethylene bearings in total hip arthroplasty. With wear rates below 0.1 mm/year now commonly being reported for highly cross-linked polyethylene (XLPE) components, it is important to identify the accuracy of the methods used to measure such small movements. The aims of this study were to compare the accuracy of current software programs used to measure two-dimensional (2D) femoral head penetration (FHP) and to determine whether the accuracy is influenced by larger femoral heads or by different methods of representing the acetabular component within radiostereometric analysis (RSA). A hip phantom was used to compare known movements of the femoral head within a metal-backed acetabular component to FHP measured radiographically using RSA, Hip Analysis Suite (HAS), PolyWare, Ein Bild Roentgen Analyse (EBRA), and Roentgen Monographic Analysis Tool (ROMAN). RSA was significantly more accurate than the HAS, PolyWare, and ROMAN methods when measuring 2D FHP with a 28 mm femoral head. Femoral head size influenced the accuracy of HAS and ROMAN 2D FHP measurements, EBRA proximal measurements, and RSA measurements in the proximal and anterior direction. The use of different acetabular reference segments did not influence accuracy of RSA measurements. The superior accuracy and reduced variability of RSA wear measurements allow much smaller cohorts to be used in RSA clinical wear studies than those utilizing other software programs. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:988-996, 2017.
Collapse
Affiliation(s)
- Stuart A Callary
- Discipline of Orthopaedics and Trauma, The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Level 4 Bice Building, North Terrace, Adelaide, South Australia, 5000, Australia
| | - Lucian B Solomon
- Discipline of Orthopaedics and Trauma, The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Level 4 Bice Building, North Terrace, Adelaide, South Australia, 5000, Australia
| | - Oksana T Holubowycz
- Discipline of Orthopaedics and Trauma, The University of Adelaide, Adelaide, South Australia, Australia
| | - David G Campbell
- Wakefield Orthopaedic Clinic, Adelaide, South Australia, Australia
| | - Donald W Howie
- Discipline of Orthopaedics and Trauma, The University of Adelaide, Adelaide, South Australia, Australia.,Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Level 4 Bice Building, North Terrace, Adelaide, South Australia, 5000, Australia
| |
Collapse
|