1
|
Mungalsingh MA, Thompson B, Peterson SD, Murphy PJ. Modelling the thermal effects of stimulus airflow from the Dolphin aesthesiometer on a model eye surface. Ophthalmic Physiol Opt 2025; 45:361-371. [PMID: 39739576 PMCID: PMC11823302 DOI: 10.1111/opo.13436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 11/19/2024] [Accepted: 12/13/2024] [Indexed: 01/02/2025]
Abstract
PURPOSE To assess the ability of the Dolphin air-pulse aesthesiometer to present multiple stimuli, which are separated temporally (in sequence) or spatially (simultaneously). METHODS Two studies were performed to explore the cooling effects induced by double air-puff stimuli generated by a novel aesthesiometer composed of two micro-blower integrated units. The stimuli were delivered sequentially or simultaneously at the same or different spatial locations to an in vitro eye model monitored using thermography. The model eye was based on a 2-cm LED dome light mounted on a circuit board with an 8-V supply producing a baseline 32°C temperature. Single and repeated air-pulse stimuli varying in intensity, duration, inter-stimulus delay and stimulus location were presented to the model. The cooling effect produced was observed using a thermal camera and quantified using image analysis software. RESULTS The instrument can deliver single stimuli, repeated single stimuli with a variable time delay or multiple stimuli either simultaneously or with a time delay between them. The thermal effects of stimuli were evaluated by measuring (relative to pre-stimulus baseline) the local temperature change and the diameter of the model eye surface region with ≥1°C reduction. Repeated stimuli at the same location produced a significantly greater effect than a single stimulus of the same intensity (larger area of cooling after the second stimulus compared to the first [|M|{SE} = 1.48 mm {0.06}, p < 0.001]). Spatially separated stimuli produced separate cooling zones, with the amount of cooling relative to stimulus intensity (rm-ANOVA, F2,8 = 276.01, p < 0.001,ω 2 = 0.96). CONCLUSIONS The combined use of two micro-blower units allows increased options for modification of stimulus intensity and timing of delivery that enables the production of alternative stimulus presentations and intensity compared to a single stimulus. This adaptability may enable future in vivo study of corneal sensory nerve summation.
Collapse
Affiliation(s)
| | - Benjamin Thompson
- School of Optometry and Vision ScienceUniversity of WaterlooWaterlooOntarioCanada
- Center for Eye and Vision ResearchHong KongChina
| | - Sean D. Peterson
- Mechanical and Mechatronics EngineeringUniversity of WaterlooWaterlooOntarioCanada
| | - Paul J. Murphy
- School of Optometry and Vision ScienceUniversity of WaterlooWaterlooOntarioCanada
| |
Collapse
|
2
|
Saigre T, Prud'homme C, Szopos M. Model order reduction and sensitivity analysis for complex heat transfer simulations inside the human eyeball. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3864. [PMID: 39250194 DOI: 10.1002/cnm.3864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 06/06/2024] [Accepted: 08/17/2024] [Indexed: 09/10/2024]
Abstract
Heat transfer in the human eyeball, a complex organ, is significantly influenced by various pathophysiological and external parameters. Particularly, heat transfer critically affects fluid behavior within the eye and ocular drug delivery processes. Overcoming the challenges of experimental analysis, this study introduces a comprehensive three-dimensional mathematical and computational model to simulate the heat transfer in a realistic geometry. Our work includes an extensive sensitivity analysis to address uncertainties and delineate the impact of different variables on heat distribution in ocular tissues. To manage the model's complexity, we employed a very fast model reduction technique with certified sharp error bounds, ensuring computational efficiency without compromising accuracy. Our results demonstrate remarkable consistency with experimental observations and align closely with existing numerical findings in the literature. Crucially, our findings underscore the significant role of blood flow and environmental conditions, particularly in the eye's internal tissues. Clinically, this model offers a promising tool for examining the temperature-related effects of various therapeutic interventions on the eye. Such insights are invaluable for optimizing treatment strategies in ophthalmology.
Collapse
Affiliation(s)
- Thomas Saigre
- Institut de Recherche Mathématique Avancée, UMR 7501 Université de Strasbourg et CNRS, Strasbourg, France
| | - Christophe Prud'homme
- Institut de Recherche Mathématique Avancée, UMR 7501 Université de Strasbourg et CNRS, Strasbourg, France
| | - Marcela Szopos
- Université Paris Cité, CNRS, MAP5, F75006, Paris, France
| |
Collapse
|
3
|
Brugnera M, Vicario-de-la-Torre M, González-Cela Casamayor MA, López-Cano JJ, Bravo-Osuna I, Huete-Toral F, González Rubio ML, Carracedo G, Molina-Martínez IT, Andrés-Guerrero V, Herrero-Vanrell R. Enhancing the hypotensive effect of latanoprost by combining synthetic phosphatidylcholine liposomes with hyaluronic acid and osmoprotective agents. Drug Deliv Transl Res 2024; 14:2804-2822. [PMID: 38602615 PMCID: PMC11385046 DOI: 10.1007/s13346-024-01584-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/18/2024] [Indexed: 04/12/2024]
Abstract
The first line of glaucoma treatment focuses on reducing intraocular pressure (IOP) through the prescription of topical prostaglandin analogues, such as latanoprost (LAT). Topical ophthalmic medicines have low bioavailability due to their rapid elimination from the ocular surface. Nanotechnology offers innovative ways of enhancing the ocular bioavailability of antiglaucoma agents while reducing administration frequency. This study aims to combine LAT-loaded synthetic phosphatidylcholine liposomes with hyaluronic acid (0.2% w/v) and the osmoprotectants betaine (0.40% w/v) and leucine (0.90% w/v) (LAT-HA-LIP) to extend the hypotensive effect of LAT while protecting the ocular surface. LAT-HA-LIP was prepared as a mixture of 1,2-dioleoyl-sn-glycero-3-phosphocholine and 1,2-dimyristoyl-sn-glycero-3-phosphocholine, cholesterol and α-tocopherol acetate. LAT-HA-LIP exhibited high drug-loading capacity (104.52 ± 4.10%), unimodal vesicle sizes (195.14 ± 14.34 nm) and a zeta potential of -13.96 ± 0.78 mV. LAT-HA-LIP was isotonic (284.00 ± 1.41 mOsm L-1), had neutral pH (7.63 ± 0.01) and had suitable surface tension (44.07 ± 2.70 mN m-1) and viscosity (2.69 ± 0.15 mPa s-1) for topical ophthalmic administration. LAT-HA-LIP exhibited optimal in vitro tolerance in human corneal and conjunctival epithelial cells. No signs of ocular alteration or discomfort were observed when LAT-HA-LIP was instilled in albino male New Zealand rabbits. Hypotensive studies revealed that, after a single eye drop, the effect of LAT-HA-LIP lasted 24 h longer than that of a marketed formulation and that relative ocular bioavailability was almost three times higher (p < 0.001). These findings indicate the potential ocular protection and hypotensive effect LAT-HA-LIP offers in glaucoma treatment.
Collapse
Affiliation(s)
- Marco Brugnera
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain
- University Institute of Industrial Pharmacy (IUFI), Faculty of Pharmacy, UCM, Madrid, Spain
| | - Marta Vicario-de-la-Torre
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain
- University Institute of Industrial Pharmacy (IUFI), Faculty of Pharmacy, UCM, Madrid, Spain
| | - Miriam Ana González-Cela Casamayor
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain
| | - José Javier López-Cano
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain
| | - Irene Bravo-Osuna
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain
- University Institute of Industrial Pharmacy (IUFI), Faculty of Pharmacy, UCM, Madrid, Spain
| | - Fernando Huete-Toral
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, UCM, Madrid, Spain
| | - María Luisa González Rubio
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, UCM, Madrid, Spain
| | - Gonzalo Carracedo
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, UCM, Madrid, Spain
| | - Irene Teresa Molina-Martínez
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain
- University Institute of Industrial Pharmacy (IUFI), Faculty of Pharmacy, UCM, Madrid, Spain
| | - Vanessa Andrés-Guerrero
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain.
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain.
- University Institute of Industrial Pharmacy (IUFI), Faculty of Pharmacy, UCM, Madrid, Spain.
| | - Rocío Herrero-Vanrell
- Innovation, Therapy and Pharmaceutical Development in Ophthalmology (InnOftal) Research Group, Complutense University of Madrid (UCM), Madrid, Spain.
- Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, UCM; IdISSC, Madrid, Spain.
- University Institute of Industrial Pharmacy (IUFI), Faculty of Pharmacy, UCM, Madrid, Spain.
| |
Collapse
|
4
|
Kawali A, Khanum A, Mishra SB, Sanjay S, Mahendradas P, Shetty R. Quantitative and comparative analysis of thermography parameters in posterior scleritis, choroiditis, and controls. Indian J Ophthalmol 2024; 72:1026-1030. [PMID: 38454839 PMCID: PMC11329813 DOI: 10.4103/ijo.ijo_2830_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/25/2023] [Accepted: 12/02/2023] [Indexed: 03/09/2024] Open
Abstract
PURPOSE To compare various ocular thermography parameters in posterior scleritis (PS), choroiditis (choroidal granuloma [CG], Vogt-Koyanagi-Harada [VKH] syndrome), central serous chorioretinopathy (CSCR), and healthy controls. METHODS This retrospective, observational, comparative study evaluated cases undergoing ocular thermography between April 2017 and October 2023. The study groups included cases of PS, CG, and VKH, while the control group comprised CSCR cases and healthy individuals. Various thermography parameters were assessed, which were as follows: Ocular surface temperature (OST), central corneal temperature (CCT), average scleral temperature (ST), nasal scleral temperature (nST), temperature difference between both the eyes (∆t), and difference between scleral and corneal temperatures (ST - CCT, nST - CCT). RESULTS It was found that ∆t was significantly higher in the PS group compared to the CG ( P = 0.005), CSCR ( P = 0.0001), and control groups (dilated control: P =0.006, undilated control: P = 0.0001). ST - CCT and nST - CCT were significantly higher in the undilated control and CSCR groups and significantly lower in the PS group. ST - CCT and nST - CCT showed less difference in the affected eyes compared to contralateral healthy eyes of PS and CG cases. OST, CCT, ST, and nST displayed statistically insignificant differences across all groups. CONCLUSION It is advisable to focus on temperature differences between the affected and healthy eyes, or the difference between the central corneal and scleral temperature of the affected eye, utilizing parameters such as ∆t, ST - CCT, and nST - CCT. These composite parameters offer a more effective approach than individual measurements like OST, CCT, ST, and nST. Thermography can serve as a screening tool to suspect and differentiate PS.
Collapse
Affiliation(s)
- Ankush Kawali
- Department of Uveitis and Ocular Immunology, Narayana Nethralaya, Bangalore, Karnataka, India
| | - Aayesha Khanum
- Department of Retina, Narayana Nethralaya, Bangalore, Karnataka, India
| | - Sai Bhakti Mishra
- Department of Uveitis and Ocular Immunology, Narayana Nethralaya, Bangalore, Karnataka, India
| | - Srinivasan Sanjay
- Department of Uveitis and Ocular Immunology, Narayana Nethralaya, Bangalore, Karnataka, India
| | - Padmamalini Mahendradas
- Department of Uveitis and Ocular Immunology, Narayana Nethralaya, Bangalore, Karnataka, India
| | - Rohit Shetty
- Department of Refractive Surgery, Narayana Nethralaya, Bangalore, Karnataka, India
| |
Collapse
|
5
|
Li X, Chen W, Li H, Shen B, He J, Gao H, Bin F, Li H, Xiao D. Temperature Self-Compensating Intelligent Wireless Measuring Contact Lens for Quantitative Intraocular Pressure Monitoring. ACS APPLIED MATERIALS & INTERFACES 2024; 16:22522-22531. [PMID: 38651323 DOI: 10.1021/acsami.4c02289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Flexible bioelectronic devices that can perform real-time and accurate intraocular pressure (IOP) monitoring in both clinical and home settings hold significant implications for the diagnosis and treatment of glaucoma, yet they face challenges due to the open physiological environment of the ocular. Herein, we develop an intelligent wireless measuring contact lens (WMCL) incorporating a dual inductor-capacitor-resistor (LCR) resonant system to achieve temperature self-compensation for quantitative IOP monitoring in different application environments. The WMCL utilizes a compact circuitry design, which enables the integration of low-frequency and high-frequency resonators within a single layer of a sensing circuit without causing visual impairment. Mechanically guided microscale 3D encapsulation strategy combined with flexible circuit printing techniques achieves the surface-adaptive fabrication of the WMCL. The specific design of frequency separation imparts distinct temperature response characteristics to the dual resonators, and the linear combination of the dual resonators can eliminate the impact of temperature variations on measurement accuracy. The WMCL demonstrates outstanding sensitivity and linearity in monitoring the IOP of porcine eyes in vitro while maintaining satisfactory measurement accuracy even with internal temperature variations exceeding 10 °C. Overcoming the impact of temperature variations on IOP monitoring from the system level, the WMCL showcases immense potential as the next generation of all-weather IOP monitoring devices.
Collapse
Affiliation(s)
- Xu Li
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Wei Chen
- Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
- Beijing University of Technology, Beijing 100124, China
| | - Hongyang Li
- Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Biwen Shen
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Jiangang He
- Avic Chengdu Aircraft Design & Research Institute, Chengdu 610041, China
| | - Huanlin Gao
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Fengjiao Bin
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Hui Li
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Dengbao Xiao
- Institute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
6
|
Gupta PK, Pancholi SS, Das P. In Vitro Drug Release Testing Method For Nepafenac Ophthalmic Suspension. J Pharm Sci 2024; 113:1061-1067. [PMID: 38042345 DOI: 10.1016/j.xphs.2023.11.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 11/24/2023] [Accepted: 11/24/2023] [Indexed: 12/04/2023]
Abstract
In vitro release test (IVRT) method is important to monitor batch-to-batch quality variations during pharmaceutical manufacturing and also to show the pharmaceutical equivalence of a generic product with the innovator. To fulfil regulatory requirements for approval of a generic ophthalmic suspension product, in vitro release study is required. No compendial or non-compendial method is available for IVRT of nepafenac ophthalmic suspension. Current research is aimed to screen various approaches using different conventional and non-conventional instruments to suggest the most suitable technique appropriate for nepafenac ophthalmic suspension followed by optimization of method parameters and validation. The trials used the paddle apparatus (USP Type-2) with dialysis sacs, the flow-through cell apparatus (USP Type-4), the rotating bottle apparatus, and the Franz diffusion cell apparatus. With the USP Type-4 apparatus drug release was found to be ∼ 83% in the simulated tear fluid (STF) of pH 7.4 in 120 min that increased to ∼ 97% upon the addition of surfactant sodium lauryl sulfate (SLS). With USP Type-2 and Franz diffusion cell apparatus, the drug release was either slow or not reaching close to the complete release. Whereas, in the case of the rotating bottle apparatus, a burst release profile was observed. The estimation of the drug release was done by the HPLC method and all the method validation parameters like specificity, accuracy, linearity, and precision were found to be within acceptance criteria.
Collapse
Affiliation(s)
- Pawan Kumar Gupta
- Department of Chemistry, Mehsana Urban Institute of Sciences, Ganpat University, Ganpat-Vidyanagar, Kherva - 384012, Dist. Mehsana, Gujarat, India
| | - Shyam Sunder Pancholi
- Department of Pharmaceutical Chemistry and Quality Assurance, Shree S. K. Patel College of Pharmaceutical Education and Research, Ganpat University, Ganpat-Vidyanagar, Kherva - 384012, Dist. Mehsana, Gujarat, India
| | - Prasanta Das
- Department of Chemistry, Mehsana Urban Institute of Sciences, Ganpat University, Ganpat-Vidyanagar, Kherva - 384012, Dist. Mehsana, Gujarat, India.
| |
Collapse
|
7
|
Phan CM, Wy Chan V, Drolle E, Hui A, Ngo W, Bose S, Shows A, Liang S, Sharma V, Subbaraman L, Zheng Y, Shi X, Wu J, Jones L. Evaluating the in vitro wettability and coefficient of friction of a novel and contemporary reusable silicone hydrogel contact lens materials using an in vitro blink model. Cont Lens Anterior Eye 2024; 47:102129. [PMID: 38423868 DOI: 10.1016/j.clae.2024.102129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 02/09/2024] [Accepted: 02/20/2024] [Indexed: 03/02/2024]
Abstract
PURPOSE To evaluate the in vitro wettability and coefficient of friction of a novel amphiphilic polymeric surfactant (APS), poly(oxyethylene)-co-poly(oxybutylene) (PEO-PBO) releasing silicone hydrogel (SiHy) contact lens material (serafilcon A), compared to other reusable SiHy lens materials. METHODS The release of fluorescently-labelled nitrobenzoxadiazole (NBD)-PEO-PBO was evaluated from serafilcon A over 7 days in a vial. The wettability and coefficient of friction of serafilcon A and three contemporary SiHy contact lens materials (senofilcon A; samfilcon A; comfilcon A) were evaluated using an in vitro blink model over their recommended wearing period; t = 0, 1, 7, 14 days for all lens types and t = 30 days for samfilcon A and comfilcon A (n = 4). Sessile drop contact angles were determined and in vitro non-invasive keratographic break-up time (NIKBUT) measurements were assessed on a blink model via the OCULUS Keratograph 5 M. The coefficient of friction was measured using a nano tribometer. RESULTS The relative fluorescence of NBD-PEO-PBO decreased in serafilcon A by approximately 18 % after 7 days. The amount of NBD-PEO-PBO released on day 7 was 50 % less than the amount released on day 1 (6.5±1.0 vs 3.4±0.5 µg/lens). The reduction in PEO-PBO in the lens also coincided with an increase in contact angles for serafilcon A after 7 days (p < 0.05), although there were no changes in NIKBUT or coefficient of friction (p > 0.05). The other contact lens materials had stable contact angles and NIKBUT over their recommended wearing period (p > 0.05), with the exception of samfilcon A, which had an increase in contact angle after 14 days as compared to t = 0 (p < 0.05). Senofilcon A and samfilcon A also showed an increase in coefficient of friction at 14 and 30 days, respectively, compared to their blister pack values (p < 0.05). CONCLUSION The results indicate that serafilcon A gradually depletes its reserve of PEO-PBO over 1 week, but this decrease did not significantly change the lens performance in vitro during this time frame.
Collapse
Affiliation(s)
- Chau-Minh Phan
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China.
| | - Vivian Wy Chan
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Elizabeth Drolle
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Alex Hui
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Australia
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China
| | - Susmita Bose
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Amanda Shows
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Shuang Liang
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Vinay Sharma
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | | | - Ying Zheng
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Xinfeng Shi
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - James Wu
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China
| |
Collapse
|
8
|
Di Zazzo A, Barabino S, Fasciani R, Aragona P, Giannaccare G, Villani E, Rolando M. One Soul and Several Faces of Evaporative Dry Eye Disease. J Clin Med 2024; 13:1220. [PMID: 38592038 PMCID: PMC10932174 DOI: 10.3390/jcm13051220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/02/2024] [Accepted: 02/04/2024] [Indexed: 04/10/2024] Open
Abstract
The ocular surface system interacts with, reacts with, and adapts to the daily continuous insults, trauma, and stimuli caused by direct exposure to the atmosphere and environment. Several tissue and para-inflammatory mechanisms interact to guarantee such an ultimate function, hence maintaining its healthy homeostatic equilibrium. Evaporation seriously affects the homeostasis of the system, thereby becoming a critical trigger in the pathogenesis of the vicious cycle of dry eye disease (DED). Tear film lipid composition, distribution, spreading, and efficiency are crucial factors in controlling water evaporation, and are involved in the onset of the hyperosmolar and inflammatory cascades of DED. The structure of tear film lipids, and subsequently the tear film, have a considerable impact on tears' properties and main functions, leading to a peculiar clinical picture and specific management.
Collapse
Affiliation(s)
- Antonio Di Zazzo
- Ophthalmology Complex Operative Unit, Foundation Campus Bio-Medico University Hospital, 00128 Rome, Italy
- Ophthalmology Unit, Campus Bio-Medico University, 00128 Rome, Italy
| | - Stefano Barabino
- Ocular Surface & Dry Eye Center, ASST Fatebenefratelli SACCO, Kilan Univeristy, 20123 Milan, Italy;
| | - Romina Fasciani
- Ophthalmology Unit, “Fondazione Policlinico Universitario A. Gemelli IRCCS”, 00128 Rome, Italy;
- Ophtalmology Unit, Catholic University of “Sacro Cuore”, 00128 Rome, Italy
| | - Pasquale Aragona
- Ophthalmology Clinic, Department of Biomedical Sciences, University Hospital of Messina, 98122 Messina, Italy;
| | - Giuseppe Giannaccare
- Eye Clinic, Department of Surgical Sciences, University of Cagliari, 09124 Cagliari, Italy;
| | - Edoardo Villani
- Eye Clinic, San Giuseppe Hospital, IRCCS Multimedica, University of Milan, 20123 Milan, Italy;
| | - Maurizio Rolando
- Ocular Surface and Dry Eye Center, ISPRE Ophthalmics, 16129 Genoa, Italy;
| |
Collapse
|
9
|
Mungalsingh MA, Thompson B, Peterson SD, Murphy PJ. Stimulus characteristics of a novel air-based multiple stimulus aesthesiometer. Ophthalmic Physiol Opt 2024; 44:32-41. [PMID: 37994563 DOI: 10.1111/opo.13252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/24/2023] [Accepted: 10/31/2023] [Indexed: 11/24/2023]
Abstract
PURPOSE To identify the stimulus airflow characteristics and confirm the consistency of a novel air jet-based aesthesiometer capable of producing and applying multiple stimuli separated either by time and/or by space. METHODS A novel aesthesiometer (Dolphin Aesthesiometer) was designed around a micro-blower under software management. Two nozzle attachments assisted in airflow control (flexible tube 1.6 mm diameter; brass tube 0.5 mm diameter). Four studies that tested the characteristics of the airflow and stimulus consistency were completed: (i) airflow pattern/trajectory, (ii) airflow surface dispersion, (iii) force of airflow across a range of stimulus strengths and (iv) thermal effects on the ocular surface. RESULTS Stimulus characteristic studies revealed: (i) airflow is coherent within the expected test distance range for the instrument, and spread rate is constant irrespective of stimulus strength; (ii) airflow dispersion occurs upon encountering a surface and dispersion increases with increasing airflow rate; (iii) a consistent and small force (10-4 N) is applied by the airflow and (iv) repeatable thermal effects occur in relation to the airflow, and the mode of stimulation of the Dolphin aesthesiometer is predominantly thermal in nature. CONCLUSIONS These studies confirm the repeatability and consistency of the novel instrument. The device is suitable for measuring corneal sensitivity. The availability of additional air jets allows the application of multiple stimuli to facilitate corneal summation investigations.
Collapse
Affiliation(s)
- Melanie A Mungalsingh
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Benjamin Thompson
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
- Center for Eye and Vision Research, Hong Kong, China
| | - Sean D Peterson
- Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Paul J Murphy
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
10
|
Akkaya B. Preparation and characterization of lysozyme loaded cryogel for heavy metal removal. Int J Biol Macromol 2023; 253:127494. [PMID: 37858643 DOI: 10.1016/j.ijbiomac.2023.127494] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 08/28/2023] [Accepted: 10/15/2023] [Indexed: 10/21/2023]
Abstract
In the present study, monolithic poly(N-isopropylacrylamide-acrylamide)-acrilic acid (poly(npam-aam)-aac) cryogels were made. Swelling tests, SEM, XRD, and ATR-FTIR analyses revealed distinct cryogel and lysozyme-loaded cryogel properties. The equilibrium swelling degree was 6.2 g H2O/g cryogel. The created poly(npam-aam)-aac with pores of 10-100 μm was obviously seen in SEM images. Lysozyme adsorption capacity on poly(npam-aam)-aac was found to be 260 mg/g at pH 7.4 and 40 °C. After that, we used lysozyme adsorbed cryogel for the removal of the model heavy metal ion (cadmium). A series of pH, duration, and ionic strengths were used to conduct Cd2+ adsorption experiments. The results showed that the new adsorbent had a considerable chemical affinity for Cd2+ ions in its ability to bind them under eye ocular conditions (pH 7.4, 32-36 °C, 0,15 M NaCl). The traditional Langmuir adsorption model was the most suitable, achieving maximum uptake of ∼185 mg/g. Chemical adsorption was found to be the rate-controlling step, and the process was also compatible with the pseudo-second-order model. For the treatment of ocular pathologies, the most effective enzyme, lysozyme, must show its function. That is why there is a need for using lysozyme, and lysozyme is selected as a lignad to adsorb heavy metal ions because of its high heavy metal binding affinity. This material could be used for the treatment of ocular pathologies in the future.
Collapse
Affiliation(s)
- Birnur Akkaya
- Sivas Cumhuriyet University Science Faculty, Department of Molecular Biology and Genetics, Sivas, Turkey.
| |
Collapse
|
11
|
Salih AE, Butt H. Multifunctional transition and temperature-responsive contact lenses. LIGHT, SCIENCE & APPLICATIONS 2023; 12:271. [PMID: 37957141 PMCID: PMC10643561 DOI: 10.1038/s41377-023-01304-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/22/2023] [Accepted: 10/10/2023] [Indexed: 11/15/2023]
Abstract
Smart contact lenses have recently gained traction due to their functionalization as noninvasive diagnostic and therapeutic wearables that can address several ocular diseases. Herein, multifunctional contact lenses exhibiting UV-transition and temperature-responsive capabilities were developed utilizing chromogenic materials that were integrated simultaneously into poly(2-hydroxyethyl methacrylate) (pHEMA) contact lenses. The functionalities of the contact lenses were optically evaluated in both their activated and non-activated states. Transition contact lenses offered excellent UV and blue light blocking capabilities (~45%) at their inactive states. When activated via UV exposure, the transparent lenses darkened instantaneously and absorbed portions of the visible light spectrum. The absorption intensity and transient discoloration of the transition lenses relied primarily on the utilized photochromic material. Likewise, the temperature-responsive contact lenses exhibited distinct colorimetric variations in response to temperature changes within the physiological range (33-38 °C). The maximum sensitivity of the thermochromic lens was 8% transmitted light per Celsius degree shift. Physiochemical and morphological analysis indicated the adequacy of the contact lenses. Hence, the multifunctional contact lenses can be deployed as smart wearables to manage ophthalmic deficiencies that are deterred by UV radiations and variations in ocular surface temperature.
Collapse
Affiliation(s)
- Ahmed E Salih
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi, UAE.
| | - Haider Butt
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi, UAE.
| |
Collapse
|
12
|
Joshi PH, Youssef AAA, Ghonge M, Varner C, Tripathi S, Dudhipala N, Majumdar S. Gatifloxacin Loaded Nano Lipid Carriers for the Management of Bacterial Conjunctivitis. Antibiotics (Basel) 2023; 12:1318. [PMID: 37627738 PMCID: PMC10451836 DOI: 10.3390/antibiotics12081318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 08/12/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023] Open
Abstract
Bacterial conjunctivitis (BC) entails inflammation of the ocular mucous membrane. Early effective treatment of BC can prevent the spread of the infection to the intraocular tissues, which could lead to bacterial endophthalmitis or serious visual disability. In 2003, gatifloxacin (GTX) eyedrops were introduced as a new broad-spectrum fluoroquinolone to treat BC. Subsequently, GTX use was extended to other ocular bacterial infections. However, due to precorneal loss and poor ocular bioavailability, frequent administration of the commercial eyedrops is necessary, leading to poor patient compliance. Thus, the goal of the current investigation was to formulate GTX in a lipid-based drug delivery system to overcome the challenges with the existing marketed eyedrops and, thus, improve the management of bacterial conjunctivitis. GTX-NLCs and SLNs were formulated with a hot homogenization-probe sonication method. The lead GTX-NLC formulation was characterized and assessed for in vitro drug release, antimicrobial efficacy (against methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa), and ex vivo permeation. The lead formulation exhibited desired physicochemical characteristics, an extended release of GTX over a 12 h period, and was stable over three months at the three storage conditions (refrigerated, room temperature, and accelerated). The transcorneal flux and permeability of GTX from the GTX-NLC formulation were 5.5- and 6.0-fold higher in comparison to the commercial eyedrops and exhibited a similar in vitro antibacterial activity. Therefore, GTX-NLCs could serve as an alternative drug delivery platform to improve treatment outcomes in BC.
Collapse
Affiliation(s)
- Poorva H. Joshi
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, University of Mississippi, University, MS 38677, USA; (P.H.J.); (A.A.A.Y.); (M.G.); (C.V.); (N.D.)
| | - Ahmed Adel Ali Youssef
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, University of Mississippi, University, MS 38677, USA; (P.H.J.); (A.A.A.Y.); (M.G.); (C.V.); (N.D.)
- Department of Pharmaceutical Technology, Faculty of Pharmacy, Kafrelsheikh University, Kafrelsheikh 33516, Egypt
| | - Mihir Ghonge
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, University of Mississippi, University, MS 38677, USA; (P.H.J.); (A.A.A.Y.); (M.G.); (C.V.); (N.D.)
| | - Corinne Varner
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, University of Mississippi, University, MS 38677, USA; (P.H.J.); (A.A.A.Y.); (M.G.); (C.V.); (N.D.)
| | - Siddharth Tripathi
- National Center for Natural Products Research, Research Institute of Pharmaceutical Sciences, University of Mississippi, University, MS 38677, USA;
| | - Narendar Dudhipala
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, University of Mississippi, University, MS 38677, USA; (P.H.J.); (A.A.A.Y.); (M.G.); (C.V.); (N.D.)
| | - Soumyajit Majumdar
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, University of Mississippi, University, MS 38677, USA; (P.H.J.); (A.A.A.Y.); (M.G.); (C.V.); (N.D.)
- Research Institute of Pharmaceutical Sciences, University of Mississippi, University, MS 38677, USA
| |
Collapse
|
13
|
Alves M, Asbell P, Dogru M, Giannaccare G, Grau A, Gregory D, Kim DH, Marini MC, Ngo W, Nowinska A, Saldanha IJ, Villani E, Wakamatsu TH, Yu M, Stapleton F. TFOS Lifestyle Report: Impact of environmental conditions on the ocular surface. Ocul Surf 2023; 29:1-52. [PMID: 37062427 DOI: 10.1016/j.jtos.2023.04.007] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 04/06/2023] [Indexed: 04/18/2023]
Abstract
Environmental risk factors that have an impact on the ocular surface were reviewed and associations with age and sex, race/ethnicity, geographical area, seasonality, prevalence and possible interactions between risk factors are reviewed. Environmental factors can be (a) climate-related: temperature, humidity, wind speed, altitude, dew point, ultraviolet light, and allergen or (b) outdoor and indoor pollution: gases, particulate matter, and other sources of airborne pollutants. Temperature affects ocular surface homeostasis directly and indirectly, precipitating ocular surface diseases and/or symptoms, including trachoma. Humidity is negatively associated with dry eye disease. There is little data on wind speed and dewpoint. High altitude and ultraviolet light exposure are associated with pterygium, ocular surface degenerations and neoplastic disease. Pollution is associated with dry eye disease and conjunctivitis. Primary Sjögren syndrome is associated with exposure to chemical solvents. Living within a potential zone of active volcanic eruption is associated with eye irritation. Indoor pollution, "sick" building or house can also be associated with eye irritation. Most ocular surface conditions are multifactorial, and several environmental factors may contribute to specific diseases. A systematic review was conducted to answer the following research question: "What are the associations between outdoor environment pollution and signs or symptoms of dry eye disease in humans?" Dry eye disease is associated with air pollution (from NO2) and soil pollution (from chromium), but not from air pollution from CO or PM10. Future research should adequately account for confounders, follow up over time, and report results separately for ocular surface findings, including signs and symptoms.
Collapse
Affiliation(s)
- Monica Alves
- Department of Ophthalmology and Otorhinolaryngology, University of Campinas Campinas, Brazil.
| | - Penny Asbell
- Department of Bioengineering, University of Memphis, Memphis, USA
| | - Murat Dogru
- School of Optometry and Vision Science, UNSW, Sydney, NSW, Australia
| | - Giuseppe Giannaccare
- Department of Ophthalmology, University Magna Graecia of Catanzaro, Cantanzaro, Italy
| | - Arturo Grau
- Department of Ophthalmology, Pontifical Catholic University of Chile, Santiago, Chile
| | - Darren Gregory
- Department of Ophthalmology, University of Colorado School of Medicine, Aurora, USA
| | - Dong Hyun Kim
- Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea
| | | | - William Ngo
- School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Anna Nowinska
- Clinical Department of Ophthalmology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland
| | - Ian J Saldanha
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Edoardo Villani
- Department of Clinical Sciences and Community Health, University of Milan, Eye Clinic, San Giuseppe Hospital, IRCCS Multimedica, Milan, Italy
| | - Tais Hitomi Wakamatsu
- Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, São Paulo Hospital, Federal University of São Paulo, Brazil
| | - Mitasha Yu
- Sensory Functions, Disability and Rehabilitation Unit, World Health Organization, Geneva, Switzerland
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW, Sydney, NSW, Australia
| |
Collapse
|
14
|
Kaya F, Bozkurt G, Ozcan C, Cortu A, Kilic Yildiz BN. Could the different estrus periods significantly affect body temperature on clinical examination in bitches? J Therm Biol 2023. [DOI: 10.1016/j.jtherbio.2023.103547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
|
15
|
NIR photothermal-activable drug-conjugated microcapsules for in vitro targeted delivery and release: An alternative treatment of diabetic retinopathy. Int J Pharm 2023; 635:122700. [PMID: 36764419 DOI: 10.1016/j.ijpharm.2023.122700] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 02/01/2023] [Accepted: 02/04/2023] [Indexed: 02/11/2023]
Abstract
Diabetic retinopathy (DR) is one of the most serious complications of diabetes, which leads to blindness. By addressing the traditional treatment limitations, we developed a novel light-responsive targeted polymeric microcapsule able to encapsulate a near infrared (NIR) photoactive fluorophore - Indocyanine Green, owing to its photothermal properties. Moreover, for an efficient in vitro targeted drug delivery, the fluorescent microsystem was conjugated with a therapeutic agent, i.e., Avastin drug - a Food and Drug Administration approved therapeutic antibody. The microcapsules were fabricated and evaluated in terms of morphology, encapsulation and drug conjugation efficiency and its release capacity. Avastin-conjugated microcapsules with an average dimension of 4.5 ± 0.35 μm were obtained, according to Scanning Electron Microscopy and Re-Scanning Confocal Microscopy (RCM) investigations. The capacity of the microcapsules to operate as effective phototherapeutic agents by generating heat under NIR laser irradiation was evaluated, followed by the investigation of the microcapsule's shell rupture and NIR laser-induced release of Avastin. The biocompatibility of the Avastin-conjugated microcapsules was proven by WST-1 assay. In vitro cellular internalization and localization of the Avastin microcarriers were determined through Conventional fluorescence microscopy, RCM and Transmission Electron Microscopy imaging techniques. Finally, the Avastin-conjugated microcapsules were validated for in vitro targeted drug delivery and release directly under simulated DR conditions, which could certainly become a successful strategy in DR fighting.
Collapse
|
16
|
Gulias-Cañizo R, Rodríguez-Malagón ME, Botello-González L, Belden-Reyes V, Amparo F, Garza-Leon M. Applications of Infrared Thermography in Ophthalmology. Life (Basel) 2023; 13:life13030723. [PMID: 36983878 PMCID: PMC10053626 DOI: 10.3390/life13030723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 02/13/2023] [Accepted: 02/24/2023] [Indexed: 03/10/2023] Open
Abstract
Body temperature is one of the key vital signs for determining a disease’s severity, as it reflects the thermal energy generated by an individual’s metabolism. Since the first study on the relationship between body temperature and diseases by Carl Reinhold August Wunderlich at the end of the 19th century, various forms of thermometers have been developed to measure body temperature. Traditionally, methods for measuring temperature can be invasive, semi-invasive, and non-invasive. In recent years, great technological advances have reduced the cost of thermographic cameras, which allowed extending their use. Thermal cameras capture the infrared radiation of the electromagnetic spectrum and process the images to represent the temperature of the object under study through a range of colors, where each color and its hue indicate a previously established temperature. Currently, cameras have a sensitivity that allows them to detect changes in temperature as small as 0.01 °C. Along with its use in other areas of medicine, thermography has been used at the ocular level for more than 50 years. In healthy subjects, the literature reports that the average corneal temperature ranges from 32.9 to 36 °C. One of the possible sources of variability in normal values is age, and other possible sources of variation are gender and external temperature. In addition to the evaluation of healthy subjects, thermography has been used to evaluate its usefulness in various eye diseases, such as Graves’ orbitopathy, and tear duct obstruction for orbital diseases. The ocular surface is the most studied area. Ocular surface temperature is influenced by multiple conditions, one of the most studied being dry eye; other diseases studied include allergic conjunctivitis and pterygium as well as systemic diseases such as carotid artery stenosis. Among the corneal diseases studied are keratoconus, infectious keratitis, corneal graft rejection, the use of scleral or soft contact lenses, and the response to refractive or cataract surgery. Other diseases where thermographic features have been reported are glaucoma, diabetic retinopathy, age-related macular degeneration, retinal vascular occlusions, intraocular tumors as well as scleritis, and other inflammatory eye diseases.
Collapse
Affiliation(s)
- Rosario Gulias-Cañizo
- Centro de Investigación en Ciencias de la Salud, Universidad Anahuac México, Naucalpan de Juárez 52786, Mexico
| | - Maria Elisa Rodríguez-Malagón
- Division of Health Sciences, Department of Clinical Sciences, University of Monterrey, San Pedro Gaza García 66238, Mexico
| | - Loubette Botello-González
- Division of Health Sciences, Department of Clinical Sciences, University of Monterrey, San Pedro Gaza García 66238, Mexico
| | - Valeria Belden-Reyes
- Division of Health Sciences, Department of Clinical Sciences, University of Monterrey, San Pedro Gaza García 66238, Mexico
| | - Francisco Amparo
- Division of Health Sciences, Department of Clinical Sciences, University of Monterrey, San Pedro Gaza García 66238, Mexico
| | - Manuel Garza-Leon
- Division of Health Sciences, Department of Clinical Sciences, University of Monterrey, San Pedro Gaza García 66238, Mexico
- Correspondence:
| |
Collapse
|
17
|
Anatychuk L, Zadorozhnyy O, Naumenko V, Kobylianskyi R, Kustryn T, Nasinnyk I, Korol A, Pasyechnikova N. Device Development for Ocular Surface Temperature and Heat Flux Density Measurement. Curr Eye Res 2023; 48:441-446. [PMID: 36594458 DOI: 10.1080/02713683.2023.2165104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
PURPOSE Currently, much attention is paid to measuring the temperature of the ocular surface in various ophthalmic diseases. However, for a comprehensive assessment of heat transfer of the eye, it is advisable to measure both the ocular surface temperature and the heat flux (HF) density. This will expand our knowledge of the physiology of the eye and create new possibilities for diagnosing ocular pathology. The present study aimed to develop a thermoelectric device to study rabbits' ocular surface temperature and HF density. METHODS The multichannel thermoelectric device was developed to measure the ocular surface temperature and HF density. This study included ten rabbits (20 eyes). In all animals, the temperature and the HF density were measured on the surface of the central cornea of both eyes. The measurement was repeated after pupils' dilation. RESULTS The corneal surface temperature of rabbits was 33.1 ± 0.8 °C, and the HF density of the surface of the cornea was 8.3 ± 0.6 mW/cm2. Our results revealed a high degree of interocular symmetry in the surface HF density in healthy rabbits. After pupil dilation, an increase in the HF density on the surface of the rabbit cornea compared with the initial data and control eye was noted. CONCLUSIONS The application of the developed device showed that it is safe and allows for the measurement of the ocular surface temperature and the HF density. We believe that further studies on the ocular surface HF density measurement in various eye diseases will allow us to evaluate the possibilities of this device and technique for diagnostic purposes.
Collapse
Affiliation(s)
- Lukyan Anatychuk
- Institute of Thermoelectricity of the National Academy of Sciences of Ukraine and the Ministry of Education and Science of Ukraine, Chernivtsi, Ukraine.,Department of Thermoelectricity, Yuriy Fedkovych Chernivtsi National University, Chernivtsi, Ukraine
| | - Oleg Zadorozhnyy
- State Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", Odesa, Ukraine
| | - Volodymyr Naumenko
- State Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", Odesa, Ukraine
| | - Roman Kobylianskyi
- Institute of Thermoelectricity of the National Academy of Sciences of Ukraine and the Ministry of Education and Science of Ukraine, Chernivtsi, Ukraine.,Department of Thermoelectricity, Yuriy Fedkovych Chernivtsi National University, Chernivtsi, Ukraine
| | - Taras Kustryn
- State Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", Odesa, Ukraine
| | - Illia Nasinnyk
- State Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", Odesa, Ukraine
| | - Andrii Korol
- State Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", Odesa, Ukraine
| | - Nataliya Pasyechnikova
- State Institution "The Filatov Institute of Eye Diseases and Tissue Therapy of the National Academy of Medical Sciences of Ukraine", Odesa, Ukraine
| |
Collapse
|
18
|
Prpic A, Kasumovic A, Guarro IG, Matoc I, Mirosevic G, Zrinscak O, Ivekovic R, Vickovic IP, Loncar VL, Vatavuk Z, Sabol I. The Role of Thermal Camera in the Assessment of Thyroid Eye Disease Activity. Acta Inform Med 2023; 31:260-264. [PMID: 38379681 PMCID: PMC10875954 DOI: 10.5455/aim.2023.31.260-264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Accepted: 12/18/2023] [Indexed: 02/22/2024] Open
Abstract
Background Thyroid eye disease (TED; also known as thyroid - associated orbitopathy, Graves ophthalmopathy) is an autoimmune inflammatory disease which presents in typical signs and symptoms such as deep orbital pain, chemosis with or without caruncular edema, unilateral or bilateral proptosis, eyelid retraction, eyelid edema or erythema, restrictive strabismus and compressive optic neuropathy. Objective The aim of this study was to investigate the role of thermal camera in the assessment of thyroid eye disease (TED) activity compared to the Clinical Activity Score (CAS) scale, exophthalmometry values, and thyroid hormone and antibody levels. Methods A total of 50 patients participated in this cross-sectional study of whom 29 were in the active phase of TED according to the sum on CAS scale and 21 patients in the inactive phase. The Flir E8® thermal camera was used to measure the temperature of the orbital area and the values were compared with the CAS scale, exophthalmometry values and thyroid hormone and antibody levels. Results Higher values of temperature (p>0.0001), CAS score (p>0.0001), exophthalmometry (p=0.022), FT4 (p=0.0176) and TRAb (p=0.0091) were found in patients in the active phase of TED. Temperature of orbital area showed statistically significant positive correlation with CAS scale (p=0.0001), exophthalmometry values (p=0.0022) and anti-TPO levels (p=0.019). Conclusion Thermal camera showed higher values of the temperature of the orbital area in patients in the active phase of the disease and positively correlated with the CAS scale, exophthalmometry findings and anti-TPO levels.
Collapse
Affiliation(s)
- Ante Prpic
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Armin Kasumovic
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Idoia Goñi Guarro
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Ines Matoc
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Gorana Mirosevic
- Clinic for Thyroid Diseases at the Department of Endocrinology, Diabetes and Metabolic Diseases “Mladen Sekso”, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Ognjen Zrinscak
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Renata Ivekovic
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Ivanka Petric Vickovic
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | | | - Zoran Vatavuk
- Department of Ophthalmology, University Hospital Center Sestre Milosrdnice, Zagreb, Croatia
| | - Ivan Sabol
- Division of Molecular Medicine, Rudjer Bosković Institute, Zagreb, Croatia
| |
Collapse
|
19
|
Micheletti E, El-Nimri NW, Weinreb RN, Liu JHK. Relative Stability of Regional Facial and Ocular Temperature Measurements in Healthy Individuals. Transl Vis Sci Technol 2022; 11:15. [PMID: 36580323 PMCID: PMC9804027 DOI: 10.1167/tvst.11.12.15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Purpose Non-contact measurement of facial temperature using infrared thermography has been used for mass screening of body temperature during a pandemic. We investigated the relative stability of temperature measurement in different facial regions of healthy individuals. Methods Twenty healthy subjects underwent two experiments. In the first experiment, subjects washed their faces with a 20°C wet towel for 1 minute. Temperature changes compared to baseline in the forehead, cornea, inner canthus, and outer canthus were determined using an infrared camera for 10 minutes. In the second experiment, lubricating eye drops at 20°C were instilled over one eye. Temperature changes in the same regions of interest were monitored for 5 minutes. Results Baseline temperatures before face washing in the forehead and cornea, inner canthus, and outer canthus of the right eye were 33.4°C ± 0.8°C (mean ± SD), 33.3°C ± 0.8°C, 34.3°C ± 0.7°C, and 32.8°C ± 0.7°C, respectively. Reductions in temperature due to face washing were most significant for the forehead and least significant for the cornea. One minute after face washing, the corresponding changes were -2.8°C ± 0.6°C, -0.3°C ± 0.6°C, -0.6°C ± 0.7°C, and -0.9°C ± 0.7°C for the forehead, cornea, inner canthus, and outer canthus, respectively. After administering the eye drops, no significant temperature changes were observed. Conclusions When facial temperature was exogenously cooled, the cornea had the most stable temperature readings. Translational Relevance When using infrared thermography to screen facial temperature, the measurement of corneal temperature is probably a better representative if the stability of temperature readings is critical.
Collapse
Affiliation(s)
- Eleonora Micheletti
- Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Nevin W. El-Nimri
- Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - Robert N. Weinreb
- Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| | - John H. K. Liu
- Viterbi Family Department of Ophthalmology, Shiley Eye Institute, University of California, San Diego, La Jolla, CA, USA
| |
Collapse
|
20
|
Iwashita H, Sebbag L, Leonard BC, Saito A. A review of diagnostic tests for qualitative and quantitative tear film deficiency in dogs. Vet Ophthalmol 2022; 26 Suppl 1:5-15. [PMID: 36575128 DOI: 10.1111/vop.13044] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 11/22/2022] [Indexed: 12/29/2022]
Abstract
Dry eye disease (DED) is a complex multifactorial condition caused by loss of ocular surface homeostasis from quantitative and/or qualitative tear film deficiency. Schirmer tear test (STT) is often the only diagnostic test used to assess for DED in veterinary practice. STT is invaluable in the diagnosis and monitoring of quantitative tear film deficiency (i.e., keratoconjunctivitis sicca); however, it is not sufficient to optimize therapy and fully recognize other contributing factors for the disturbance in ocular surface homeostasis. The present work reviews diagnostic tests for assessing aqueous tear production in veterinary medicine, as well as the quality of tears, corneal epithelial barrier integrity, and the lacrimal functional unit.
Collapse
Affiliation(s)
| | - Lionel Sebbag
- Koret School of Veterinary Medicine, The Hebrew University of Jerusalem, Rehovot, Israel
| | - Brian C Leonard
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California Davis, California, USA
| | | |
Collapse
|
21
|
Szalai B, Jójárt-Laczkovich O, Kovács A, Berkó S, Balogh GT, Katona G, Budai-Szűcs M. Design and Optimization of In Situ Gelling Mucoadhesive Eye Drops Containing Dexamethasone. Gels 2022; 8:gels8090561. [PMID: 36135271 PMCID: PMC9498616 DOI: 10.3390/gels8090561] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 08/26/2022] [Accepted: 08/29/2022] [Indexed: 11/17/2022] Open
Abstract
Poor bioavailability of eye drops is a well-known issue, which can be improved by increasing the residence time on the eye surface and the penetration of the active pharmaceutical ingredient (API). This study aims to formulate in situ gelling mucoadhesive ophthalmic preparations. To increase the residence time, the formulations were based on a thermosensitive polymer (Poloxamer 407 (P407)) and were combined with two types of mucoadhesive polymers. Dexamethasone (DXM) was solubilized by complexation with cyclodextrins (CD). The effect of the composition on the gel structure, mucoadhesion, dissolution, and permeability was investigated with 33 full factorial design. These parameters of the gels were measured by rheological studies, tensile test, dialysis membrane diffusion, and in vitro permeability assay. The dissolution and permeability of the gels were also compared with DXM suspension and CD-DXM solution. The gelation is strongly determined by P407; however, the mucoadhesive polymers also influenced it. Mucoadhesion increased with the polymer concentration. The first phase of drug release was similar to that of the CD-DXM solution, then it became prolonged. The permeability of DXM was significantly improved. The factorial design helped to identify the most important factors, thereby facilitating the formulation of a suitable carrier for the CD-DXM complex.
Collapse
Affiliation(s)
- Boglárka Szalai
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Eötvös Str. 6, H-6720 Szeged, Hungary
| | - Orsolya Jójárt-Laczkovich
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Eötvös Str. 6, H-6720 Szeged, Hungary
| | - Anita Kovács
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Eötvös Str. 6, H-6720 Szeged, Hungary
| | - Szilvia Berkó
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Eötvös Str. 6, H-6720 Szeged, Hungary
| | - György Tibor Balogh
- Department of Pharmacodynamics and Biopharmacy, Faculty of Pharmacy, University of Szeged, Eötvös Str. 6, H-6720 Szeged, Hungary
- Department of Chemical and Environmental Process Engineering, Budapest University of Technology and Economics, Műegyetem Quay 3, H-1111 Budapest, Hungary
| | - Gábor Katona
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Eötvös Str. 6, H-6720 Szeged, Hungary
| | - Mária Budai-Szűcs
- Institute of Pharmaceutical Technology and Regulatory Affairs, Faculty of Pharmacy, University of Szeged, Eötvös Str. 6, H-6720 Szeged, Hungary
- Correspondence: ; Tel.: +36-6254-5573
| |
Collapse
|
22
|
López-Cano JJ, González-Cela-Casamayor MA, Andrés-Guerrero V, Vicario-de-la-Torre M, Benítez Del Castillo JM, Herrero-Vanrell R, Molina-Martínez IT. Development of an osmoprotective microemulsion as a therapeutic platform for ocular surface protection. Int J Pharm 2022; 623:121948. [PMID: 35752388 DOI: 10.1016/j.ijpharm.2022.121948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 06/03/2022] [Accepted: 06/19/2022] [Indexed: 10/17/2022]
Abstract
Self-emulsified osmoprotective ophthalmic microemulsions (O/A) were prepared by combining betaine/leucine, clusterin/oleanolic acid, and hyaluronic acid or Dextran. The microemulsions contained an internal oily phase (1.2%), an external aqueous phase (96.3%), cosolvents (1%), and surfactants (1.5%). Physicochemical characterization and in vivo and in vitro tolerance were analyzed. The formulations' osmoprotective in vitro activity was assayed in a hyperosmolar model in human corneal cells. Average internal phase sizes were 16-26 nm for the microemulsions including Dextran. Addition of hyaluronic acid increased the size range (25-39 nm). Addition of osmoprotectants did not change nanodroplet size. The formulations were isotonic (280-290 mOsm/L) with neutral pH (≈7) and zeta potential (-10 to 0 mV), low surface tension (≈35-40mN·m-1), and low viscosity (≈1 mPa·s), except for the microemulsions containing hyaluronic acid (≈4-5 mPa·s). SEM and cryo-TEM showed that all formulations exhibited sphere-shaped morphology with good cell tolerance (≈100%) and were stable at 8 °C for 9 months. Osmoprotective formulations were well tolerated in vitro and in vivo, protecting cells from hypertonic stress. We therefore developed stable microemulsions compatible with the ocular surface that could constitute a novel tool for treatment of ophthalmic diseases.
Collapse
Affiliation(s)
- J J López-Cano
- Ophthalmology Innovation, Therapy and Pharmaceutical Development (InnOftal) Research Group, UCM 920415, Department of Pharmaceutics and Food Technology, Faculty of Pharmacy (UCM), Plaza Ramón y Cajal s/n, Madrid 28040, Spain; National Ocular Pathology Network (OFTARED), Carlos III Health Institute, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain
| | - M A González-Cela-Casamayor
- Ophthalmology Innovation, Therapy and Pharmaceutical Development (InnOftal) Research Group, UCM 920415, Department of Pharmaceutics and Food Technology, Faculty of Pharmacy (UCM), Plaza Ramón y Cajal s/n, Madrid 28040, Spain; National Ocular Pathology Network (OFTARED), Carlos III Health Institute, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain
| | - V Andrés-Guerrero
- Ophthalmology Innovation, Therapy and Pharmaceutical Development (InnOftal) Research Group, UCM 920415, Department of Pharmaceutics and Food Technology, Faculty of Pharmacy (UCM), Plaza Ramón y Cajal s/n, Madrid 28040, Spain; National Ocular Pathology Network (OFTARED), Carlos III Health Institute, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain
| | - M Vicario-de-la-Torre
- Ophthalmology Innovation, Therapy and Pharmaceutical Development (InnOftal) Research Group, UCM 920415, Department of Pharmaceutics and Food Technology, Faculty of Pharmacy (UCM), Plaza Ramón y Cajal s/n, Madrid 28040, Spain; National Ocular Pathology Network (OFTARED), Carlos III Health Institute, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain
| | - J M Benítez Del Castillo
- National Ocular Pathology Network (OFTARED), Carlos III Health Institute, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain; Ocular Surface and Inflammation Unit, Ophthalmology Department, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain
| | - R Herrero-Vanrell
- Ophthalmology Innovation, Therapy and Pharmaceutical Development (InnOftal) Research Group, UCM 920415, Department of Pharmaceutics and Food Technology, Faculty of Pharmacy (UCM), Plaza Ramón y Cajal s/n, Madrid 28040, Spain; National Ocular Pathology Network (OFTARED), Carlos III Health Institute, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain.
| | - I T Molina-Martínez
- Ophthalmology Innovation, Therapy and Pharmaceutical Development (InnOftal) Research Group, UCM 920415, Department of Pharmaceutics and Food Technology, Faculty of Pharmacy (UCM), Plaza Ramón y Cajal s/n, Madrid 28040, Spain; National Ocular Pathology Network (OFTARED), Carlos III Health Institute, San Carlos Clinical Hospital Health Research Institute (IdISSC), Madrid 28040, Spain.
| |
Collapse
|
23
|
The Effect of Face Masks during COVID-19 Pandemic on Ocular Surface Temperature-A Clinical Thermographic Analysis. Diagnostics (Basel) 2022; 12:diagnostics12061431. [PMID: 35741241 PMCID: PMC9221900 DOI: 10.3390/diagnostics12061431] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 06/02/2022] [Accepted: 06/03/2022] [Indexed: 11/18/2022] Open
Abstract
Due to the COVID-19 pandemic, the center for disease control and prevention (CDC) recommends face-mask wearing for all people above the age of two years. The wearing of face masks creates a unique airflow towards the ocular surface which may influence the normal physiological conditions of the ocular and periocular surface. Healthy subjects with no ocular history were enrolled in this cross-sectional study. The Therm-App thermal imaging camera was used for ocular surface temperature (OST) measurements during inspirium and expirium. Five regions of interest (ROIs) were used to measure OST: medial conjunctive, cornea, lateral conjunctive, upper eyelid and entire orbital area. Additional measurements in the same locations were made with the upper margin of the mask taped with micropore surgical tape. Thirty-one patients were included in this study. OST during expirium was significantly higher compared to the temperature during inspirium in all locations measured (p < 0.001, paired samples t-test). The temperature of the upper eyelid was higher by more than 0.5 °C during expirium. Taping the mask’s upper edges to the skin resulted in non-significant temperature changes in inspirium vs. expirium. In conclusion, wearing a face mask creates air flow towards the periocular and ocular surface, which changes the OST mostly on the eyelids.
Collapse
|
24
|
Viitaja T, Raitanen JE, Hynynen A, Moilanen J, Svedström K, Paananen RO, Ekholm FS. On the importance of chain branching in tear film lipid layer wax and cholesteryl esters. Colloids Surf B Biointerfaces 2022; 214:112429. [PMID: 35278859 DOI: 10.1016/j.colsurfb.2022.112429] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 02/22/2022] [Accepted: 02/23/2022] [Indexed: 11/30/2022]
Abstract
The tear film lipid layer (TFLL) is important to the maintenance of ocular surface health. Surprisingly, information on the individual roles of the myriad of unique lipids found therein is limited. The most abundant lipid species are the wax esters (WE) and cholesteryl esters (CE), and, especially their branched analogs. The isolation of these lipid species from the TFLL has proved to be tedious, and as a result, insights on their biophysical profiles and role in the TFLL is currently lacking. Herein, we circumvent these issues by a total synthesis of the most abundant iso-methyl branched WEs and CEs found in the TFLL. Through a detailed characterization of the biophysical properties, by the use of Langmuir monolayer and wide-angle X-ray scattering techniques, we demonstrate that chain branching alters the behavior of these lipid species on multiple levels. Taken together, our results fill an important knowledge gap concerning the structure and function of the TFLL on the whole.
Collapse
Affiliation(s)
- Tuomo Viitaja
- Department of Chemistry, University of Helsinki, P.O. Box 55, Helsinki FI-00014, Finland; Ophthalmology, University of Helsinki and Helsinki University Hospital, Haartmaninkatu 8, Helsinki FI-00290, Finland
| | - Jan-Erik Raitanen
- Department of Chemistry, University of Helsinki, P.O. Box 55, Helsinki FI-00014, Finland
| | - Antti Hynynen
- Department of Chemistry, University of Helsinki, P.O. Box 55, Helsinki FI-00014, Finland
| | - Jukka Moilanen
- Ophthalmology, University of Helsinki and Helsinki University Hospital, Haartmaninkatu 8, Helsinki FI-00290, Finland
| | - Kirsi Svedström
- Department of Physics, University of Helsinki, P.O. Box 64, Helsinki FI-00014, Finland
| | - Riku O Paananen
- Department of Chemistry, University of Helsinki, P.O. Box 55, Helsinki FI-00014, Finland; Ophthalmology, University of Helsinki and Helsinki University Hospital, Haartmaninkatu 8, Helsinki FI-00290, Finland.
| | - Filip S Ekholm
- Department of Chemistry, University of Helsinki, P.O. Box 55, Helsinki FI-00014, Finland.
| |
Collapse
|
25
|
Clasky DP, Meunier L, Wells LA. Modeling the Effects of Disease, Drug Properties, and Material on Drug Transport From Intraocular Lenses. Transl Vis Sci Technol 2022; 11:14. [PMID: 35575775 PMCID: PMC9123490 DOI: 10.1167/tvst.11.5.14] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Surgically implanted intraocular lenses (IOLs) may be used as drug-delivery devices, but their effectiveness is not well defined. Computational fluid dynamics models were developed to investigate the capability of IOLs to release drugs at therapeutic concentrations. Methods Models were generated using COMSOL Multiphysics. Primary open-angle glaucoma (POAG) and wet age-related macular degeneration (AMD) were simulated by reducing aqueous vein and choroidal blood flow, respectively. Release of dexamethasone, ganciclovir, or dextran was studied using common IOL materials, polydimethylsiloxane (PDMS) and poly(2-hydroxyethyl methacrylate) (PHEMA). Results Drug clearance proceeds mainly through choroidal blood flow. When fully constricted, maximum concentration at the choroid (Cmax) values increased by 32.4% to 39,800%. Compared to dexamethasone, Cmax in different tissues decreased by 6.07% to 96.0% for ganciclovir and dextran, and clearance rates decreased by 16% to 69% for ganciclovir and by 92% to 100% for dextran. Using PDMS as the IOL reduced clearance rates by 91.3% to 94.6% compared to PHEMA. Conclusions In diseased eyes, drugs accumulate mainly in posterior tissue; thus, choroidal drug toxicity must be assessed prior to IOL implantation in POAG and AMD patients. Moreover, drug properties modulated concentration profiles in all ocular segments. The hydrophobic small-molecule dexamethasone attained the highest concentrations and cleared the fastest, whereas hydrophilic macromolecular dextran attained the lowest concentrations and cleared the slowest. Furthermore, high concentrations were achieved quickly following release from PHEMA, whereas PDMS allowed for sustained release. Translational Relevance In silico results can guide scientists and clinicians regarding important physiological and chemical factors that modulate tissue drug concentrations from drug-eluting IOLs.
Collapse
Affiliation(s)
- Danielle P Clasky
- Department of Chemical Engineering, Queen's University, Kingston, Ontario, Canada
| | - Louise Meunier
- Department of Chemical Engineering, Queen's University, Kingston, Ontario, Canada
| | - Laura A Wells
- Department of Chemical Engineering, Queen's University, Kingston, Ontario, Canada.,Centre for Health Innovation, Queen's University and Kingston Health Sciences Centre, Kingston, Ontario, Canada
| |
Collapse
|
26
|
Madl AC, Liu C, Cirera-Salinas D, Fuller GG, Myung D. A Mucin-Deficient Ocular Surface Mimetic Platform for Interrogating Drug Effects on Biolubrication, Antiadhesion Properties, and Barrier Functionality. ACS APPLIED MATERIALS & INTERFACES 2022; 14:18016-18030. [PMID: 35416028 PMCID: PMC9052192 DOI: 10.1021/acsami.1c22280] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 03/03/2022] [Indexed: 05/14/2023]
Abstract
Dry eye disease (DED) affects more than 100 million people worldwide, causing significant patient discomfort and imposing a multi-billion-dollar burden on global health care systems. In DED patients, the natural biolubrication process that facilitates pain-free blinking goes awry due to an imbalance of lipids, aqueous medium, and mucins in the tear film, resulting in ocular surface damage. Identifying strategies to reduce adhesion and shear stresses between the ocular surface and the conjunctival cells lining the inside of the eyelid during blink cycles is a promising approach to improve the signs and symptoms of DED. However, current preclinical models for screening ocular lubricants rely on scarce, heterogeneous tissue samples or model substrates that do not capture the complex biochemical and biophysical cues present at the ocular surface. To recapitulate the hierarchical architecture and phenotype of the ocular interface for preclinical drug screening, we developed an in vitro mucin-deficient DED model platform that mimics the complexity of the ocular interface and investigated its utility in biolubrication, antiadhesion, and barrier protection studies using recombinant human lubricin, a promising investigational therapy for DED. The biomimetic platform recapitulated the pathological changes in biolubrication, adhesion, and barrier functionality often observed in mucin-deficient DED patients and demonstrated that recombinant human lubricin can reverse the damage induced by mucin loss in a dose- and conformation-dependent manner. Taken together, these results highlight the potential of the platform─and recombinant human lubricin─in advancing the standard of care for mucin-deficient DED patients.
Collapse
Affiliation(s)
- Amy C. Madl
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - Chunzi Liu
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - Daniel Cirera-Salinas
- Biologics
Analytical Research and Development, Novartis
Pharma AG, Basel 4002, Switzerland
| | - Gerald G. Fuller
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
| | - David Myung
- Department
of Chemical Engineering, Stanford University, Stanford, California 94305, United States
- Byers
Eye Institute, Stanford University School
of Medicine, Palo Alto, California 94303, United States
| |
Collapse
|
27
|
Xu X, Li G, Zuo YY. Biophysical properties of tear film lipid layer I. Surface tension and surface rheology. Biophys J 2022; 121:439-450. [PMID: 34958775 PMCID: PMC8822608 DOI: 10.1016/j.bpj.2021.12.033] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Revised: 12/04/2021] [Accepted: 12/22/2021] [Indexed: 02/03/2023] Open
Abstract
Tear film lipid layer (TFLL) is the outmost layer of the tear film. It plays a crucial role in stabilizing the tear film by reducing surface tension and retarding evaporation of the aqueous layer. Dysfunction of the TFLL leads to dysfunctional tear syndrome, with dry eye disease (DED) being the most prevalent eye disease, affecting 10%-30% of the world population. To date, except for treatments alleviating dry eye symptoms, effective therapeutic interventions in treating DED are still lacking. Therefore, there is an urgent need to understand the biophysical properties of the TFLL with the long-term goal to develop translational solutions in effectively managing DED. Here, we studied the composition-function correlations of an artificial TFLL, under physiologically relevant conditions, using a novel experimental methodology called constrained drop surfactometry. This artificial TFLL was composed of 40% behenyl oleate and 40% cholesteryl oleate, representing the most abundant wax ester and cholesteryl ester in the natural TFLL, respectively, and 15% phosphatidylcholine and 5% palmitic-acid-9-hydroxy-stearic-acid (PAHSA), which represent the two predominant polar lipid classes in the natural TFLL. Our study suggests that the major biophysical function of phospholipids in the TFLL is to reduce the surface tension, whereas the primary function of PAHSA is to optimize the rheological properties of the TFLL. These findings have novel implications in better understanding the physiological and biophysical functions of the TFLL and may offer new translational insight to the treatment of DED.
Collapse
Affiliation(s)
- Xiaojie Xu
- Department of Mechanical Engineering, University of Hawaii at Manoa, Honolulu
| | - Guangle Li
- Department of Mechanical Engineering, University of Hawaii at Manoa, Honolulu
| | - Yi Y. Zuo
- Department of Mechanical Engineering, University of Hawaii at Manoa, Honolulu,Department of Pediatrics, John A. Burns School of Medicine, University of Hawaii, Honolulu,Corresponding author
| |
Collapse
|
28
|
Topical Pirfenidone-Loaded Liposomes Ophthalmic Formulation Reduces Haze Development after Corneal Alkali Burn in Mice. Pharmaceutics 2022; 14:pharmaceutics14020316. [PMID: 35214048 PMCID: PMC8875218 DOI: 10.3390/pharmaceutics14020316] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 01/17/2022] [Accepted: 01/18/2022] [Indexed: 12/04/2022] Open
Abstract
Corneal chemical burns (CCBs) frequently result in corneal fibrosis or haze, an opacity of the cornea that obstructs vision and induces corneal blindness. Diverse strategies have been employed to prevent or reduce CCB-related corneal haze. In this study, we evaluated the physicochemical characteristics and biologic effects of a topical pirfenidone (PFD)-loaded liposomal formulation (PL) on a corneal alkali burn mice model. We found that PL was appropriate for ocular application due to its physiologic tear pH, osmolarity and viscosity suitable for topical ophthalmic use. Regarding its therapeutic activity, PL-treated mice had significantly reduced haze size and density, corneal edema, corneal thickness, and corneal inflammatory infiltration, in contrast to PFD in aqueous solution (p < 0.01). Importantly, the antifibrotic activity of PL (reduction of corneal haze) was associated with modulation of transforming growth factor (TGF)-β and Interleukin (IL)-1β genes. PL suppressed TGF-β expression and restored normal IL-1β expression in corneal tissue more efficiently in contrast to PFD in aqueous solution. In conclusion, PFD showed essential anti-inflammatory and anti-fibrotic effects in the treatment of alkali burns. Noteworthy, a new formulation of PFD-loaded liposomes remarkably improved these effects, standing out as a promising treatment for corneal haze.
Collapse
|
29
|
Rohde F, Walther M, Wächter J, Knetzger N, Lotz C, Windbergs M. In-situ tear fluid dissolving nanofibers enable prolonged viscosity-enhanced dual drug delivery to the eye. Int J Pharm 2022; 616:121513. [PMID: 35085733 DOI: 10.1016/j.ijpharm.2022.121513] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 01/20/2022] [Accepted: 01/21/2022] [Indexed: 12/29/2022]
Abstract
Liquid and semi-solid formulations are the most commonly used drug delivery systems for ophthalmic diseases. Upon application into the conjunctival sac, these systems introduce a variable and unphysiologically high liquid volume to the eye, resulting in overflow and extensive nasolacrimal drainage, accounting for dosing inaccuracy and short ocular residence time. In this study, we present nanofibrous electrospun scaffolds composed of biocompatible polymers, overcoming these challenges by immediate drug release. The fibers incorporate gentamicin and dexamethasone, intended for the treatment of bacterial conjunctivitis. Upon contact with the ocular surface, the nanofibers immediately dissolve in the tear fluid, quantitatively releasing the two actives, yielding over92% drug recovery, determined with fluorimetric and chromatographic quantifications methods. Simultaneously, the viscosity of the tear fluid increases, shown by complex viscometry measurements. A newly developed ex vivo microfluidic porcine cornea model was used to evaluated ocular residence time. In contrast to fluid eye drops, the contact time was significantly prolonged and 20min after application, an increase in drug availability on the ocular surface of 342% was observed. Biocompatibility of the polymer system was demonstrated in an OECD approved in vitro cornea model. The antibacterial activity after processing was evaluated according to EUCAST guidelines, and storage stability of the system was confirmed over a 12-week period. This innovative drug delivery system poses a highly promising platform technology, overcoming challenges associated with conventional dosage forms for drug delivery to the anterior eye and thus significantly advancing therapeutic approaches.
Collapse
Affiliation(s)
- F Rohde
- Institute of Pharmaceutical Technology and Buchmann Institute for Molecular Life Sciences, Goethe University Frankfurt, Max-von-Laue-Str. 9, 60438 Frankfurt am Main, Germany
| | - M Walther
- Institute of Pharmaceutical Technology and Buchmann Institute for Molecular Life Sciences, Goethe University Frankfurt, Max-von-Laue-Str. 9, 60438 Frankfurt am Main, Germany
| | - J Wächter
- Institute of Pharmaceutical Technology and Buchmann Institute for Molecular Life Sciences, Goethe University Frankfurt, Max-von-Laue-Str. 9, 60438 Frankfurt am Main, Germany
| | - N Knetzger
- Translational Center for Regenerative Therapies (TLZ-RT), Fraunhofer Institute for Silicate Research (ISC), Neunerplatz 2, 97082 Würzburg, Germany; Chair of Tissue Engineering and Regenerative Medicine (TERM), University Hospital Würzburg, Röntgenring 11, 97070 Würzburg, Germany
| | - C Lotz
- Translational Center for Regenerative Therapies (TLZ-RT), Fraunhofer Institute for Silicate Research (ISC), Neunerplatz 2, 97082 Würzburg, Germany; Chair of Tissue Engineering and Regenerative Medicine (TERM), University Hospital Würzburg, Röntgenring 11, 97070 Würzburg, Germany
| | - M Windbergs
- Institute of Pharmaceutical Technology and Buchmann Institute for Molecular Life Sciences, Goethe University Frankfurt, Max-von-Laue-Str. 9, 60438 Frankfurt am Main, Germany.
| |
Collapse
|
30
|
Truong LTD, Lesniewski PJ, Wedding AB. Heat transfer simulation in laser irradiated retinal tissues. Biomed Phys Eng Express 2021; 8. [PMID: 34874294 DOI: 10.1088/2057-1976/ac3f51] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 12/02/2021] [Indexed: 11/12/2022]
Abstract
A realistic model of human retinal tissues to simulate thermal performance of optical laser photocoagulation therapy is presented. The key criteria to validate the treatment effectiveness is to ensure the photocoagulation temperature between 60 and 70 °C is reached in the treatment region of interest. The model presented consists of truncated volumes of the retinal pigment epithelium (RPE) and adjacent retinal tissues. Two cases of choroid pigmentation are modelled to signify extreme cases of human eye difference: albino and dark colour choroid pigmentation. Conditions for consistent heating over the irradiated treatment spot is modelled for laser beams with different intensity profiles: 'top-hat', Gaussian and 'donut' modes. The simulation considers both uniform heating within retinal tissue layers and spatial intensity decay due to absorption along the direction of laser propagation. For a 500μm spot, pulse length 100 ms and incident power to the cornea of 200 mW, realistic spatial variation in heating results in peak temperatures increasing within the RPE and shifting towards the choroid in the case of choroidal pigmentation. Finite element analysis methodology, where heat transfer theory governs the temperature evolution throughout tissues peripheral to the irradiated RPE is used to determine the zone of therapeutic benefit. While a TEM01donut mode beam produces lower peak temperatures in the RPE for a given incident laser power, it reduces the volume of retinal tissue reaching excessive temperatures and maximises the zone of therapeutic benefit. Described are simulation limitations, boundary conditions, grid size and mesh growth factor required for realistic simulation.
Collapse
Affiliation(s)
- Linh T D Truong
- Laser Physics & Photonic Devices Laboratories, UniSA STEM, University of South Australia, Mawson Lakes, SA, 5095, Australia
| | - Peter J Lesniewski
- Laser Physics & Photonic Devices Laboratories, UniSA STEM, University of South Australia, Mawson Lakes, SA, 5095, Australia
| | - A Bruce Wedding
- Laser Physics & Photonic Devices Laboratories, UniSA STEM, University of South Australia, Mawson Lakes, SA, 5095, Australia
| |
Collapse
|
31
|
Benítez Martínez M, Baeza Moyano D, González-Lezcano RA. Phacoemulsification: Proposals for Improvement in Its Application. Healthcare (Basel) 2021; 9:1603. [PMID: 34828648 PMCID: PMC8621996 DOI: 10.3390/healthcare9111603] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Revised: 11/17/2021] [Accepted: 11/18/2021] [Indexed: 02/05/2023] Open
Abstract
A cataract is defined as opacity of the crystalline lens. It is currently one of the most prevalent ocular pathologies and is generally associated with aging. The most common treatment for cataracts is surgery. Cataract surgery is a quick and painless process, is very effective, and has few risks. The operation consists of removing the opacified lens and replacing it with an intraocular lens. The most common intraocular lens removal procedure that is currently used is phacoemulsification. The energy applied in this process is generated by ultrasonic waves, which are mechanical waves with a frequency higher than 20 kHz. A great deal of research on the different ways to perform the stages of this surgical procedure and the analysis of the possible side effects of the operation has been published, but there is little information on the technical characteristics, the intensities applied, and the use of ultrasound-emitting (U/S) equipment for cataract removal. More studies on the method and depth of absorption of ultrasonic waves in our visual system when performing the phacoemulsification procedure are needed. It would be advisable for health authorities and medical professionals to develop guidelines for the handling and use of ultrasonic wave-emitting equipment, such as those that exist for ultrasound and physiotherapy. This could help us to reduce undesirable effects after the operation.
Collapse
Affiliation(s)
- Marta Benítez Martínez
- Department of Chemistry and Biochemistry, Campus Montepríncipe, Universidad San Pablo CEU, 28668 Alcorcón, Madrid, Spain; (M.B.M.); (D.B.M.)
| | - David Baeza Moyano
- Department of Chemistry and Biochemistry, Campus Montepríncipe, Universidad San Pablo CEU, 28668 Alcorcón, Madrid, Spain; (M.B.M.); (D.B.M.)
| | - Roberto Alonso González-Lezcano
- Arquitecture and Design Department, Escuela Politécnica Superior, Campus Montpríncipe, Universidad San Pablo CEU, 28668 Alcorcón, Madrid, Spain
| |
Collapse
|
32
|
Haber-Olguin A, Polania-Baron EJ, Trujillo-Trujillo F, Graue Hernandez EO. Thermographic Behavior of the Cornea During Treatment With Two Excimer Laser Platforms. Transl Vis Sci Technol 2021; 10:27. [PMID: 34427627 PMCID: PMC8399240 DOI: 10.1167/tvst.10.9.27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Purpose To investigate the temperature of the cornea during treatment with the excimer laser using two platforms, Nidek EC-5000 and Schwind Amaris 750S. Methods A prospective case series study was conducted in a reference center in Mexico City including patients aged 18 years or older who had any type of ametropia and underwent excimer laser refractive surgery. The patients had measurements of corneal temperature with an infrared camera before, during, and after ablation treatment. Results of prior corneal surface temperature, temperatures during excimer laser surgery, and delta temperature for each platform were analyzed and compared. Results A total of 107 eyes were analyzed. Mean baseline temperature was 32.7 ± 1.03°C for the Nidek group and 31.5 ± 1.4°C for the Amaris group. Mean maximum temperature was 39.94 ± 1.3°C for the Nidek group and 35.6 ± 1.5 °C for the Amaris group. Delta temperature was higher in the Nidek group than in the Amaris group. There were statistically significant associations between treated micrometers, treated diopters, and time in the Nidek group and no such associations in the Amaris group. Conclusions The different excimer laser devices used and the variety in the optical design, together with different software ablation algorithms, resulted in different levels of thermal loading; peak temperature rose in all measurements. Eyes treated with Nidek reached temperatures that doubled those found with Amaris. Translational Relevance The correlation between Delta of temperature with defocus, depth, and treatment time is different regarding excimer laser generation.
Collapse
Affiliation(s)
- Alberto Haber-Olguin
- Department of Cornea, External Disease, and Refractive Surgery, Instituto de Oftalmología "Conde de Valenciana," Mexico City, Mexico.,Aris Vision Institute, Mexico City, Mexico
| | - Eduardo J Polania-Baron
- Department of Cornea, External Disease, and Refractive Surgery, Instituto de Oftalmología "Conde de Valenciana," Mexico City, Mexico
| | | | - Enrique O Graue Hernandez
- Department of Cornea, External Disease, and Refractive Surgery, Instituto de Oftalmología "Conde de Valenciana," Mexico City, Mexico
| |
Collapse
|
33
|
Suppression of Intracellular Reactive Oxygen Species in Human Corneal Epithelial Cells via the Combination of Quercetin Nanoparticles and Epigallocatechin Gallate and In Situ Thermosensitive Gel Formulation for Ocular Drug Delivery. Pharmaceuticals (Basel) 2021; 14:ph14070679. [PMID: 34358106 PMCID: PMC8308701 DOI: 10.3390/ph14070679] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 07/06/2021] [Accepted: 07/12/2021] [Indexed: 12/20/2022] Open
Abstract
Oxidative stress can cause several severe ophthalmological diseases. In this study, we developed a thermosensitive gel as a delivery system for two antioxidant substances, namely, quercetin and epigallocatechin gallate. The quercetin was loaded in the PLGA nanoparticles using a solvent displacement method. The physical and chemical stability of the quercetin nanoparticles were evaluated, and the degradation kinetics of the quercetin in the nanoparticles was investigated. The in vitro antioxidant and intracellular reactive oxygen species inhibition of the quercetin nanoparticles, combined with the epigallocatechin gallate (EGCG), were determined using a 2,2-diphenyl-1-picrylhydrazyl radical scavenging assay and a 2,7-dichlorodihydrofluorescein fluorescent probes, respectively. The thermosensitive gel loaded with the quercetin nanoparticles and EGCG was formulated. We confirmed that quercetin nanoparticles displayed the desired physical characteristics, release kinetics, and stability. The combination of quercetin nanoparticles and EGCG suggested the additive effect of antioxidant activity. We also demonstrated the superior intracellular ROS inhibition activity of the quercetin nanoparticles and EGCG with n-acetyl cysteine. The thermosensitive gel showed an appropriate gelation temperature and time for ocular drug delivery. Our results provide promising prospects for applying the thermosensitive gel loaded with quercetin nanoparticles and EGCG as an efficient drug delivery system for antioxidant activity in human corneal epithelial cells.
Collapse
|
34
|
Stanciauskaite M, Marksa M, Ivanauskas L, Perminaite K, Ramanauskiene K. Ophthalmic In Situ Gels with Balsam Poplar Buds Extract: Formulation, Rheological Characterization, and Quality Evaluation. Pharmaceutics 2021; 13:pharmaceutics13070953. [PMID: 34202901 PMCID: PMC8308992 DOI: 10.3390/pharmaceutics13070953] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 06/10/2021] [Accepted: 06/13/2021] [Indexed: 01/01/2023] Open
Abstract
Balsam poplar buds are a raw material with a high content of polyphenols. Various polyphenols are known for their anti-inflammatory and antioxidant properties. In this study, an aqueous extract of balsam poplar buds was prepared in order to use environmentally friendly and non-aggressive solvents. The aqueous extract was lyophilized, and a 1% aqueous solution of lyophilized balsam poplar buds extract (L1) was prepared. L1 solution was used as a source of polyphenols for the production of ophthalmic in situ gels, so as to develop a product featuring antioxidant properties. Poloxamer 407 (P407) and hydroxypropyl methylcellulose (HPMC) were selected as gelling agents for the in situ gels. In order to select the formulations with the best conditions of use, formulations of different polymer concentrations (P407—10%, 12%, 15%; HPMC—0.5%, 0.75%) were prepared, choosing the same amount of the active polyphenol source L1. The physicochemical properties, rheological parameters, stability, and irritant effect on the rabbit corneal cell line (SIRC) were evaluated. Formulations in which P407 and HMPC concentrations were 10/0.75% and 12%/0.75% reached a gelation point close to the ocular surface temperature; the gels remained stable for 30 days and did not cause an irritant effect on the SIRC cell line.
Collapse
Affiliation(s)
- Monika Stanciauskaite
- Department of Clinical Pharmacy, Faculty of Pharmacy, Lithuanian University of Health Sciences, Sukileliai Avenue 13, LT-50161 Kaunas, Lithuania; (K.P.); (K.R.)
- Correspondence: ; Tel.: +370-679-670-17
| | - Mindaugas Marksa
- Department of Analytical & Toxicological Chemistry, Faculty of Pharmacy, Lithuanian University of Health Sciences, Sukileliai Avenue 13, LT-50161 Kaunas, Lithuania; (M.M.); (L.I.)
| | - Liudas Ivanauskas
- Department of Analytical & Toxicological Chemistry, Faculty of Pharmacy, Lithuanian University of Health Sciences, Sukileliai Avenue 13, LT-50161 Kaunas, Lithuania; (M.M.); (L.I.)
| | - Kristina Perminaite
- Department of Clinical Pharmacy, Faculty of Pharmacy, Lithuanian University of Health Sciences, Sukileliai Avenue 13, LT-50161 Kaunas, Lithuania; (K.P.); (K.R.)
| | - Kristina Ramanauskiene
- Department of Clinical Pharmacy, Faculty of Pharmacy, Lithuanian University of Health Sciences, Sukileliai Avenue 13, LT-50161 Kaunas, Lithuania; (K.P.); (K.R.)
| |
Collapse
|
35
|
Monolayers of Cholesterol and Cholesteryl Stearate at the Water/Vapor Interface: A Physico-Chemical Study of Components of the Meibum Layer. COLLOIDS AND INTERFACES 2021. [DOI: 10.3390/colloids5020030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Langmuir monolayers containing different amounts of cholesterol and cholesteryl stearate were studied at two different temperatures (24 °C and 35 °C). The main goal was to contribute towards the understanding of how the variations in the chemical composition may affect the physico-chemical properties of these specific lipid monolayers. The model mixture was chosen considering that cholesteryl esters are present in cell membranes and some other biological systems, including human tear lipids. Therefore, an investigation into the effect of the lipid monolayer composition on their interfacial properties may elucidate some of the fundamental reasons for the deficiencies in cell membranes and tear film functioning in vivo. The experimental results have shown that the molar ratio of the mixture plays a crucial role in the modulation of the Langmuir film properties. The condensing effects of the cholesterol and the interactions between the lipids in the monolayer were the main factors altering the monolayer response to dilatational deformation. The modification of the mixture compositions leads to significant changes in the Langmuir films and the mechanical performance, altering the ability of the monolayer to reduce the surface tension and the viscoelastic properties of the monolayers. This suggests that subtle modifications of the biomembrane composition may significantly alter its physiological function.
Collapse
|
36
|
Shin H, Seo H, Chung WG, Joo BJ, Jang J, Park JU. Recent progress on wearable point-of-care devices for ocular systems. LAB ON A CHIP 2021; 21:1269-1286. [PMID: 33704299 DOI: 10.1039/d0lc01317j] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The eye is a complex sensory organ that contains abundant information for specific diseases and pathological responses. It has emerged as a facile biological interface for wearable healthcare platforms because of its excellent accessibility. Recent advances in electronic devices have led to the extensive research of point-of-care (POC) systems for diagnosing and monitoring diseases by detecting the biomarkers within the eye. Among these systems, contact lenses, which make direct contact with the ocular surfaces, have been utilized as one of the promising candidates for non-invasive POC testing of various diseases. The continuous and long-term measurement from the sensor allows the patients to manage their symptoms in an effective and convenient way. Herein, we review the progress of contact lens sensors in terms of the materials, methodologies, device designs, and target biomarkers. The anatomical structure and biological mechanisms of the eye are also discussed to provide a comprehensive understanding of the principles of contact lens sensors. Intraocular pressure and glucose, which are the representative biomarkers found in the eyes, can be measured with the biosensors integrated with contact lenses for the diagnosis of glaucoma and diabetes. Furthermore, contact lens sensors for various general pathologies as well as other ocular diseases are also considered, thereby providing the prospects for further developments of smart contact lenses as a future POC system.
Collapse
Affiliation(s)
- Haein Shin
- Nano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
| | | | | | | | | | | |
Collapse
|
37
|
Richdale K, Cox I, Kollbaum P, Bullimore MA, Bakaraju RC, Gifford P, Plainis S, McKenney C, Newman S, Tomiyama ES, Morgan PB. CLEAR – Contact lens optics. Cont Lens Anterior Eye 2021; 44:220-239. [DOI: 10.1016/j.clae.2021.02.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/27/2022]
|
38
|
Guo S, Wu K, Li C, Wang H, Sun Z, Xi D, Zhang S, Ding W, Zaghloul ME, Wang C, Castro FA, Yang D, Zhao Y. Integrated contact lens sensor system based on multifunctional ultrathin MoS 2 transistors. MATTER 2021; 4:969-985. [PMID: 33398259 PMCID: PMC7773002 DOI: 10.1016/j.matt.2020.12.002] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 10/28/2020] [Accepted: 12/03/2020] [Indexed: 05/19/2023]
Abstract
Smart contact lenses attract extensive interests due to their capability of directly monitoring physiological and ambient information. However, previous demonstrations usually lacked efficient sensor modalities, facile fabrication process, mechanical stability, or biocompatibility. Here, we demonstrate a flexible approach for fabrication of multifunctional smart contact lenses with an ultrathin MoS2 transistors-based serpentine mesh sensor system. The integrated sensor systems contain a photodetector for receiving optical information, a glucose sensor for monitoring glucose level directly from tear fluid, and a temperature sensor for diagnosing potential corneal disease. Unlike traditional sensors and circuit chips sandwiched in the lens substrate, this serpentine mesh sensor system can be directly mounted onto the lenses and maintain direct contact with tears, delivering high detection sensitivity, while being mechanically robust and not interfering with either blinking or vision. Furthermore, the in vitro cytotoxicity tests reveal good biocompatibility, thus holding promise as next-generation soft electronics for healthcare and medical applications.
Collapse
Affiliation(s)
- Shiqi Guo
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Kaijin Wu
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, CAS Center for Excellence in Complex System Mechanics, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Chengpan Li
- Department of Electronic Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Hao Wang
- Athioula A. Martins Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA
| | - Zheng Sun
- School of Engineering and Applied Science, The George Washington University, Washington, DC 20052, USA
| | - Dawei Xi
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Sheng Zhang
- Ningbo Research Institute, Zhejiang University, Zhejiang, Ningbo 315100, China
| | - Weiping Ding
- Department of Electronic Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Mona E Zaghloul
- School of Engineering and Applied Science, The George Washington University, Washington, DC 20052, USA
| | - Changning Wang
- Athioula A. Martins Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA
| | - Fernando A Castro
- Advanced Technology Institute, University of Surrey, Guildford, Surrey GU2 7XH, UK
- National Physical Laboratory, Teddington, Middlesex TW11 0LW, UK
| | - Dong Yang
- Athioula A. Martins Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA
| | - Yunlong Zhao
- Advanced Technology Institute, University of Surrey, Guildford, Surrey GU2 7XH, UK
- National Physical Laboratory, Teddington, Middlesex TW11 0LW, UK
| |
Collapse
|
39
|
Safety and Tolerability of Topical Ophthalmic Triamcinolone Acetonide-Loaded Liposomes Formulation and Evaluation of Its Biologic Activity in Patients with Diabetic Macular Edema. Pharmaceutics 2021; 13:pharmaceutics13030322. [PMID: 33801366 PMCID: PMC7998140 DOI: 10.3390/pharmaceutics13030322] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 02/22/2021] [Accepted: 02/24/2021] [Indexed: 01/01/2023] Open
Abstract
Intravitreal injections (IVTs) of corticosteroids as triamcinolone acetonide (TA) are frequently used for the treatment of many vitreous and retinal disorders. However, IVTs are related to severe ocular complications. Lately, a topical ophthalmic TA-loaded liposomes formulation (TALF) was designed to transport TA into the posterior segment of the eye when instilled on the ocular surface. To evaluate the safety, tolerability, and biological activity of TALF, an animal study and a phase I clinical assay were performed. Moreover, four patients with diabetic macular edema (DME) were treated with TALF in order to explore the biological activity of the formulation. No inflammation, lens opacity, swelling, or increase in intraocular pressure were recorded after the instillation of TALF in any of the animal or clinical studies. Mainly, mild and transient adverse events such as dry eye and burning were reported. TALF significantly improves visual acuity and diminishes central foveal thickness in patients with DME. The current data demonstrate the safety, tolerability, and biological activity of TALF. It seems that TALF can be used topically to treat vitreous and retinal diseases that respond to TA such as DME, avoiding the use of corticosteroid IVTs and their associated hazards.
Collapse
|
40
|
Dou Z, Tang J, Liu Z, Sun Q, Wang Y, Li Y, Yuan M, Wu H, Wang Y, Pei W, Chen H. Wearable Contact Lens Sensor for Non-invasive Continuous Monitoring of Intraocular Pressure. MICROMACHINES 2021; 12:108. [PMID: 33499080 PMCID: PMC7910926 DOI: 10.3390/mi12020108] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 01/18/2021] [Accepted: 01/19/2021] [Indexed: 02/06/2023]
Abstract
Intraocular pressure (IOP) is an essential indicator of the diagnosis and treatment of glaucoma. IOP has an apparent physiological rhythm, and it often reaches its peak value at night. To avoid missing the peak value at night and sample the entire rhythm cycle, the continuous monitoring of IOP is urgently needed. A wearable contact lens IOP sensor based on a platinum (Pt) strain gauge is fabricated by the micro-electro-mechanical (MEMS) process. The structure and parameters of the strain gauge are optimized to improve the sensitivity and temperature stability. Tests on an eyeball model indicate that the IOP sensor has a high sensitivity of 289.5 μV/mmHg and excellent dynamic cycling performance at different speeds of IOP variation. The temperature drift coefficient of the sensor is 33.4 μV/°C. The non-invasive IOP sensor proposed in this report exhibits high sensitivity and satisfactory stability, promising a potential in continuous IOP monitoring.
Collapse
Affiliation(s)
- Zhiqiang Dou
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jun Tang
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhiduo Liu
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qigong Sun
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yang Wang
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
| | - Yamin Li
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Miao Yuan
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Huijuan Wu
- Department of Ophthalmology, Peking University People’s Hospital, Beijing 100044, China;
| | - Yijun Wang
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Weihua Pei
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hongda Chen
- The State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China; (Z.D.); (J.T.); (Z.L.); (Q.S.); (Y.W.); (Y.L.); (M.Y.); (Y.W.); (H.C.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
41
|
Anatomical and physiological considerations in scleral lens wear: Eyelids and tear film. Cont Lens Anterior Eye 2021; 44:101407. [PMID: 33468392 DOI: 10.1016/j.clae.2021.01.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 12/31/2020] [Accepted: 01/07/2021] [Indexed: 12/19/2022]
Abstract
Scleral lenses can affect a range of anterior segment structures including the eyelids and the tears. The eyelids, consisting of the outer skin layer, the middle tarsal plate, and the posterior palpebral conjunctiva, provide physical protection and house the meibomian glands and cilia which have important and unique functions. Tears consist of a mix of aqueous, mucus, and lipidomic components that serve vital functions of lubricity, protection, and nourishment to the ocular surface. Both the eyelids and the tear film interact directly with scleral lenses on the eye and can affect but also be impacted by scleral lens wear. The purpose of this paper is to review the anatomy and physiology of the eyelids and tear film, discuss the effects and impacts of the scleral lenses on these structures, and identify areas that require further research.
Collapse
|
42
|
Yan T, Ma Z, Liu J, Yin N, Lei S, Zhang X, Li X, Zhang Y, Kong J. Thermoresponsive GenisteinNLC-dexamethasone-moxifloxacin multi drug delivery system in lens capsule bag to prevent complications after cataract surgery. Sci Rep 2021; 11:181. [PMID: 33420301 PMCID: PMC7794611 DOI: 10.1038/s41598-020-80476-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 12/11/2020] [Indexed: 01/29/2023] Open
Abstract
Cataract surgery is the most common intraocular procedure. To decrease postsurgical inflammation, prevent infection and reduce the incidence of secondary cataract, we built a temperature-sensitive drug delivery system carrying dexamethasone, moxifloxacin and genistein nanostructured lipid carrier (GenNLC) modified by mPEG-PLA based on F127/F68 as hydrogel. Characterizations and release profiles of the drug delivery system were studied. In vitro functions were detected by CCK-8 test, immunofluorescence, wound-healing assay, real time-PCR and western blotting. The size of GenNLCs was 39.47 ± 0.69 nm in average with surface charges of - 4.32 ± 0.84 mV. The hydrogel gelation temperature and time were 32 °C, 20 s with a viscosity, hardness, adhesiveness and stringiness of 6.135 Pa.s, 54.0 g, 22.0 g, and 3.24 mm, respectively. Transmittance of the gel-release medium was above 90% (93.44 ± 0.33% to 100%) at range of 430 nm to 800 nm. Moxifloxacin released completely within 10 days. Fifty percent of dexamethasone released at a constant rate in the first week, and then released sustainably with a tapering down rate until day 30. Genistein released slowly but persistently with a cumulative release of 63% at day 40. The thermoresponsive hydrogel inhibited the proliferation, migration and epithelial-mesenchymal transition of SRA 01/04 cells, which were confirmed by testing CCK-8, wound-healing assay, western blot, real time-PCR (RT-PCR) and immunofluorescence. These results support this intracameral thermoresponsive in situ multi-drug delivery system with programmed release amounts and release profiles to cut down the need of eye drops for preventing inflammation or infection and to reduce posterior capsular opacification following cataract surgery.
Collapse
Affiliation(s)
- Tingyu Yan
- grid.412644.1Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, No.11 Xinhua Road, Heping District, Shenyang, 110005 Liaoning Province China
| | - Zhongxu Ma
- grid.265021.20000 0000 9792 1228Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Vision Science, Clinical College of Ophthalmology, Tianjin Medical University, No. 4 Gansu Rd, Heping District, Tianjin, 300020 China
| | - Jingjing Liu
- grid.412644.1Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, No.11 Xinhua Road, Heping District, Shenyang, 110005 Liaoning Province China
| | - Na Yin
- grid.412561.50000 0000 8645 4345Department of Pharmaceutics, Shenyang Pharmaceutical University, No.103 Wen Hua Road, Shenyang, 110016 China
| | - Shizhen Lei
- grid.412644.1Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, No.11 Xinhua Road, Heping District, Shenyang, 110005 Liaoning Province China
| | - Xinxin Zhang
- grid.412644.1Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, No.11 Xinhua Road, Heping District, Shenyang, 110005 Liaoning Province China
| | - Xuedong Li
- grid.412644.1Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, No.11 Xinhua Road, Heping District, Shenyang, 110005 Liaoning Province China
| | - Yu Zhang
- grid.412561.50000 0000 8645 4345Department of Pharmaceutics, Shenyang Pharmaceutical University, No.103 Wen Hua Road, Shenyang, 110016 China
| | - Jun Kong
- grid.412644.1Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, No.11 Xinhua Road, Heping District, Shenyang, 110005 Liaoning Province China
| |
Collapse
|
43
|
Shah AM, Galor A. Impact of Ocular Surface Temperature on Tear Characteristics: Current Insights. CLINICAL OPTOMETRY 2021; 13:51-62. [PMID: 33623465 PMCID: PMC7894805 DOI: 10.2147/opto.s281601] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 01/20/2021] [Indexed: 05/12/2023]
Abstract
Infrared (IR) thermographic assessment of ocular surface temperature (OST) is gaining interest as an adjuvant method to evaluate the ocular surface. It is a quick, non-invasive test that causes minimal, if any, discomfort to patients. The purpose of this article was to summarize research on how OST relates to tear film parameters and dry eye disease (DED). PubMed, Google Scholar, and Scopus searches for specific terms were carried out and eligible articles reviewed. OST of the central cornea is ~34-35°C when measured as a single time-point (typically right after a blink). Dynamically, OST values decrease over time at a rate of ~ -0.01 °C/s in healthy eyes. Single time-point OST values are impacted by temperature, with positive correlations noted with both ambient (1°C↓ results in ~0.16°C↓ in OST) and body (1°C↑ results in ~0.98°C↑ in OST) temperature. Single time-point OST values are also impacted by tear parameters, with negative correlations noted with tear break-up time (TBUT; r=-0.61) and positive correlations with lipid layer thickness (~r=0.50). Dynamically, the rate of OST cooling over the interblink period correlates with various tear parameters including Schirmer's test scores (r=-0.39), tear meniscus height (r=-0.52) and the rate of tear film break-up (r=-0.74). These data imply that OST decreases more rapidly in individuals with greater tear production, larger tear volumes, and shorter tear break-up times (faster rates of tear film break-up). There are discrepancies in relationships between OST and DED across studies, which is not surprising given that DED encompasses a number of different phenotypic presentations. However, most studies found that OST decreases at a more rapid rate in DED vs. control groups. As such, cooling rate may have utility as a screening tool in DED in combination with established point-of-care tests.
Collapse
Affiliation(s)
- Ankit M Shah
- Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
| | - Anat Galor
- Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
- Surgical Services, Miami Veterans Affairs (VA) Medical Center, Miami, FL, USA
- Correspondence: Anat Galor Bascom Palmer Eye Institute, 900 NW 17th St, Miami, FL, 33136, USA Email
| |
Collapse
|
44
|
Jin Y, Jones L, Gorbet M. Investigation of the response of tear-film neutrophils to interleukin 8 and their sensitivity to centrifugation, fixation, and incubation. Sci Rep 2020; 10:19690. [PMID: 33184318 PMCID: PMC7665065 DOI: 10.1038/s41598-020-75806-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 10/19/2020] [Indexed: 11/26/2022] Open
Abstract
During eye closure, a large number of neutrophils (polymorphonuclear neutrophils, PMNs) invade the ocular surface and are often referred to as tear-film PMNs. While immunophenotyping experiments have been performed on tear-film PMNs, the impact of commonly used experimental procedures on their phenotype as well as their response to interleukin-8 (IL-8), a physiological inflammatory mediator, have not yet been investigated. A gentle eye wash method was used to collect cells at home. In the morning upon awaking, participants washed their eyes with sterile phosphate buffer saline (PBS) and collected the runoff into a sterile polypropylene tube. The cell collection was then delivered to the lab within two hours. The effects of centrifugation, incubation and fixation with paraformaldehyde (PFA) before (pre-fixed staining) or after (post-fixed staining) incubation with antibodies were characterized. Tear-film PMNs as well as blood PMNs (used for comparison) were also stimulated with IL-8. To assess the reproducibility of cell collection and variability in receptor expression over time, participants were also asked to collect cells three times over a period of a month. The change in expression of surface receptors, CD11b, CD16, CD55, CD66b, important inflammatory and activation markers, and CD45 (PAN leukocyte marker) was assessed by flow cytometry. Fixing tear-film PMNs prior to the staining with antibodies resulted in a significant (fivefold or more) reduction in the expression of CD11b, CD16 and CD45 when compared to unfixed samples, while CD16 was the only receptor to undergo significant downregulation upon post-staining fixation. Furthermore, additional centrifugation step prior to antibody incubation as well as long (4 h) incubation at 37 °C resulted in significant reductions in expression of CD11b, CD16 and CD55 when compared to control samples. As opposed to blood PMNs, stimulating tear-film PMNs with IL-8 did not induce any significant changes in expression of CD11b, CD16, CD55 and CD66b. When working with collected tear-film PMNs, our results suggest that any additional centrifugation and incubation step should be avoided, or at least limited, and post fixation staining is recommended in order to preserve cell phenotype and cell integrity of tear film PMNs. Our study also adds further information on the reproducibility of the gentle eye wash as well as the inability of tear-film PMNs to modulate their surface receptors upon stimulation with IL-8. The latter may be due to prior exposure to IL-8, activation in the closed-eye environment, or a reduced ability to respond to inflammatory stimulus. Further mechanistic studies will be needed to gain a better understanding of the tear-film neutrophil phenotype.
Collapse
Affiliation(s)
- Yutong Jin
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
- Centre for Ocular Research and Education, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
- Centre for Ocular Research and Education, University of Waterloo, Waterloo, Canada
| | - Maud Gorbet
- School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.
- Department of Systems Design Engineering, University of Waterloo, Waterloo, Canada.
- Centre for Ocular Research and Education, University of Waterloo, Waterloo, Canada.
| |
Collapse
|
45
|
Besifloxacin liposomes with positively charged additives for an improved topical ocular delivery. Sci Rep 2020; 10:19285. [PMID: 33159142 PMCID: PMC7648625 DOI: 10.1038/s41598-020-76381-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 10/22/2020] [Indexed: 02/08/2023] Open
Abstract
Topical ophthalmic antibiotics show low efficacy due to the well-known physiological defense mechanisms of the eye, which prevents the penetration of exogenous substances. Here, we aimed to incorporate besifloxacin into liposomes containing amines as positively charged additives and to evaluate the influence of this charge on drug delivery in two situations: (i) iontophoretic and (ii) passive treatments. Hypothesis are (i) charge might enhance the electromigration component upon current application improving penetration efficiency for a burst drug delivery, and (ii) positive charge might prolong formulation residence time, hence drug penetration. Liposomes elaborated with phosphatidylcholine (LP PC) or phosphatidylcholine and spermine (LP PC: SPM) were stable under storage at 6 ºC for 30 days, showed mucoadhesive characteristics, and were non-irritant, according to HET-CAM tests. Electron paramagnetic resonance spectroscopy measurements showed that neither the drug nor spermine incorporations produced evident alterations in the fluidity of the liposome's membranes, which retained their structural stability even under iontophoretic conditions. Mean diameter and zeta potential were 177.2 ± 2.7 nm and − 5.7 ± 0.3 mV, respectively, for LP PC; and 175.4 ± 1.9 nm and + 19.5 ± 1.0 mV, respectively, for LP PC:SPM. The minimal inhibitory concentration (MIC) and the minimal bactericide concentration (MBC) of the liposomes for P. aeruginosa showed values lower than the commercial formulation (Besivance). Nevertheless, both formulations presented a similar increase in permeability upon the electric current application. Hence, liposome charge incorporation did not prove to be additionally advantageous for iontophoretic therapy. Passive drug penetration was evaluated through a novel in vitro ocular model that simulates the lacrimal flow and challenges the formulation resistance in the passive delivery situation. As expected, LP PC: SPM showed higher permeation than the control (Besivance). In conclusion, besifloxacin incorporation into positively charged liposomes improved passive topical delivery and can be a good strategy to improve topical ophthalmic treatments.
Collapse
|
46
|
In vivo biocompatibility and efficacy of dexamethasone-loaded PLGA-PEG-PLGA thermogel in an alkali-burn induced corneal neovascularization disease model. Eur J Pharm Biopharm 2020; 155:190-198. [PMID: 32871195 DOI: 10.1016/j.ejpb.2020.08.022] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 08/06/2020] [Accepted: 08/24/2020] [Indexed: 12/19/2022]
Abstract
Challenges of ophthalmic drug delivery arise not only from the limited solubility of hydrophobic therapeutics, but also the restricted permeability and fast clearance of drugs due to the complex anatomy and physiology of eyes. Excellent biocompatibility of a thermosensitive polymer, PLGA-PEG-PLGA (1800-1500-1800, LA:GA ratio = 3:1), as an ophthalmic delivery system was demonstrated in our previous work. In this study, delivery of dexamethasone using this thermogel via a single subconjunctival injection for prolonged treatment was evaluated with corneal neovascularization using an alkali-burn diseased model in rat. Solubility of dexamethasone in the polymeric solution was increased by 5.2-fold and the resulting drug-loaded solution formed in situ rigid gel at body temperature. Prolonged in vitro release of dexamethasone from the gel structure was noted. Dexamethasone gel formulation was demonstrated to be more effective in reducing the burn stimulus and neovascularization in the rat diseased model. The findings suggest the PLGA-PEG-PLGA in situ gelling system can be applied for ophthalmic drug delivery to achieve sustained drug release and improved efficacy.
Collapse
|
47
|
Derakhshan JJ, Parvin N, Loevner LA, Wehrli FW, McKinstry RC. Effects of motion and b-value on apparent temperature measurement by diffusion-based thermometry MRI: eye vitreous study. Med Phys 2020; 47:5006-5019. [PMID: 32757301 DOI: 10.1002/mp.14435] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 07/03/2020] [Accepted: 07/21/2020] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To make noninvasive measurements of temperature in the posterior chamber (vitreous) of the eye using diffusion-based thermometry (DBT) magnetic resonance imaging (MRI) and to explain variability in these measurements due to choice of b-value and the effects of motion. METHODS Phantom studies of human vitreous and distilled water were performed using b-values from 0 to 1500 s/mm2 to determine the liquid-specific calibration factor for vitreous as well as to determine the temperature offsets due to sampling the diffusion curve using three higher routine clinical b-values (b = 0, 500, 1000 s/mm2 ) or four lower b-values (b = 0, 200, 400, 600 s/mm2 ), thought to be optimized for fluids. Retrospective ROI-based measurements of apparent diffusion coefficient on single slices as well as multi-slice histograms of the eyes were made in six patients with peri-orbital cellulitis and 11 age-matched controls, to assess for temperature changes in the presence of peri-orbital inflammation. A prospective study of ten repeated measurements of eye temperature using both high and lower b-value sampling was performed in ten asymptomatic volunteers to determine the reproducibility of eye temperature measurements in-vivo as well as to estimate vitreous temperature in the absence of motion. RESULTS The diffusion coefficient of vitreous (2,088 ± 13 × 10-6 mm2 /s) was significantly lower (-1.9%, P < 0.001) compared to distilled water (2,128 ± 12 × 10-6 mm2 /s). The calibration factor for temperature measurements of vitreous using DBT is +0.74 ± 0.06°C. Temperature offsets were smaller (<-0.2°C, P < 0.01) when using larger routine clinical b-values to estimate the diffusion coefficient compared to using a series of lower b-values (<-1.0°C, P < 0.001). Two-dimensional single-slice ROI-based measurement showed significant temperature differences (ΔTI-C = 2.5 ± 1.2°C, P < 0.001) between the eyes of patient with peri-orbital cellulitis, higher on the side of inflammation. There was no significant difference in eye temperature when using the 3D histogram (which is likely due to motion averaging as significant slice-to-slice variation was present). However, significant differences in the 3D temperature histograms between the two eyes was observed in one out of six patients. Prospective eye temperature measurements in healthy volunteers showed significant intra- and inter-subject variability (33.8-41.6°C), which was caused by eye motion. This resulted in +2.4°C cohort-wide elevation in temperature when three b-values were used and +4.7°C when four b-values were used. Using a pattern of elevated temperature at the periphery of the eye to detect motion, eye temperature is the absence of motion was estimated to be 34.5 ± 0.4°C with three higher b-values and 34.6 ± 1.9°C with four lower b-values; this temperature corresponds with prior mathematical simulations of eye temperature as well as boundary conditions. CONCLUSIONS Globe vitreous temperature has been measured noninvasively using DBT MRI. Using routine clinical b-values of b = 0, 500 and 1000 s/mm2 produces acceptable (<-0.2°C) temperature offsets. Although DBT measurements are highly susceptible to motion, methods such as temperature differences or regression can be used to reduce or eliminate the effects of motion. Using a single clinical diffusion-weighted MRI, globe temperature difference of 1.6°C is pathological. Using a series of ten measurements, globe temperature differences larger than 0.6°C are abnormal. This study suggests CSF flow likely artifactually increases core brain temperature measured by DBT MRI.
Collapse
Affiliation(s)
- Jamal J Derakhshan
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.,Department of Radiology, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Neda Parvin
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Laurie A Loevner
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Felix W Wehrli
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Robert C McKinstry
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| |
Collapse
|
48
|
Sebbag L, Mochel JP. An eye on the dog as the scientist's best friend for translational research in ophthalmology: Focus on the ocular surface. Med Res Rev 2020; 40:2566-2604. [PMID: 32735080 DOI: 10.1002/med.21716] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 07/01/2020] [Accepted: 07/15/2020] [Indexed: 12/15/2022]
Abstract
Preclinical animal studies provide valuable opportunities to better understand human diseases and contribute to major advances in medicine. This review provides a comprehensive overview of ocular parameters in humans and selected animals, with a focus on the ocular surface, detailing species differences in ocular surface anatomy, physiology, tear film dynamics and tear film composition. We describe major pitfalls that tremendously limit the translational potential of traditional laboratory animals (i.e., rabbits, mice, and rats) in ophthalmic research, and highlight the benefits of integrating companion dogs with clinical analogues to human diseases into preclinical pharmacology studies. This One Health approach can help accelerate and improve the framework in which ophthalmic research is translated to the human clinic. Studies can be conducted in canine subjects with naturally occurring or noninvasively induced ocular surface disorders (e.g., dry eye disease, conjunctivitis), reviewed herein, and tear fluid can be easily retrieved from canine eyes for various bioanalytical purposes. In this review, we discuss common tear collection methods, including capillary tubes and Schirmer tear strips, and provide guidelines for tear sampling and extraction to improve the reliability of analyte quantification (drugs, proteins, others).
Collapse
Affiliation(s)
- Lionel Sebbag
- Department of Biomedical Sciences, SMART Pharmacology, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA.,Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA
| | - Jonathan P Mochel
- Department of Biomedical Sciences, SMART Pharmacology, College of Veterinary Medicine, Iowa State University, Ames, Iowa, USA
| |
Collapse
|
49
|
Ahmedou Bamba S, Ellabib A. Nonoverlapping Dirichlet–Neumann method for transient bioheat transfer in the human eye. INT J BIOMATH 2020. [DOI: 10.1142/s1793524520500357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This paper presents a 2D simulation of transient heat transfer in the human eye using appropriate boundary conditions. The mathematical model governing bioheat transfer in the human eye is discussed and the existence and uniqueness of the solution are proven. Four methods based on finite element method and nonoverlapping domain decomposition method to obtain transient heat transfer in the human eye are presented and described in details. After conducting numerous simulations using realistic parameters obtained from the open literature and after comparison with measurements reported by previous experimental studies, all proposed methods gave an accurate representation of transient heat transfer in the human eye. The results obtained by the domain decomposition of the human eye into four subdomains are found to be the closest to reality.
Collapse
Affiliation(s)
- Salem Ahmedou Bamba
- Université Cadi Ayyad, Laboratoire de Mathématiques Appliquées et Informatique, Faculté des Sciences et Techniques Marrakech, Avenue Abdelkrim El khttabi B.P. 549, Morocco
| | - Abdellatif Ellabib
- Université Cadi Ayyad, Laboratoire de Mathématiques Appliquées et Informatique, Faculté des Sciences et Techniques Marrakech, Avenue Abdelkrim El khttabi B.P. 549, Morocco
| |
Collapse
|
50
|
Matteoli S, Vannetti F, Sodi A, Corvi A. Infrared thermographic investigation on the ocular surface temperature of normal subjects. Physiol Meas 2020; 41:045003. [PMID: 31935708 DOI: 10.1088/1361-6579/ab6b48] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE It is understood that the ability to measure ocular temperature accurately will increase understanding of ocular physiology and should be a support in decision-making in classical diagnostic procedures. The use of ocular thermography offers great opportunities for monitoring the temperature of the anterior eye and analyzing the effects of certain pathologies on ocular surface temperature (OST). The aim of the present work is to measure the OST of 220 healthy normal subjects, stratified according to gender and age, in order to obtain a normal temperature distribution to be used as reference values when comparing healthy versus pathological conditions. APPROACH The OST is measured from five regions, located over the whole area of the anterior eye, which correspond to particular anatomic structures, through a semi-automated procedure to post-process the infrared images. The relationship between OST and independent variables (forehead skin temperature, age, gender, level of physical activity, cardiovascular risk factors including sedentary lifestyle and smoking, laboratory temperature, and laboratory humidity) was investigated through linear regression models. MAIN RESULTS The OSTs measured from the five different ocular regions are statistically different (p -value < 0.001), even when dividing our subjects into males and females, with the nasal cantus being the hottest region and the central cornea the coolest; when considering also the effect of age, stratifying our subjects into young, middle-aged and elderly, the OST decreases when age increases significantly. Statistical analysis based on linear regression models pointed out that age, forehead skin temperature, and lab temperature are the main factors to be taken into account when exploring the OST. SIGNIFICANCE As OST evaluation can be important in detecting different ocular pathologies, having precise details of the variation in temperature across the ocular surface and therefore a more detailed map of the OST adjusted according to subject characteristics and environment conditions could enhance early diagnosis and thus course of treatments.
Collapse
Affiliation(s)
- Sara Matteoli
- Bioengineering laboratory, Department of Industrial Engineering, University of Florence, Florence, Italy. These authors contributed equally to this work
| | | | | | | |
Collapse
|