1
|
Cychosz M, Winn MB, Goupell MJ. How to vocode: Using channel vocoders for cochlear-implant research. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2407-2437. [PMID: 38568143 PMCID: PMC10994674 DOI: 10.1121/10.0025274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 02/23/2024] [Indexed: 04/05/2024]
Abstract
The channel vocoder has become a useful tool to understand the impact of specific forms of auditory degradation-particularly the spectral and temporal degradation that reflect cochlear-implant processing. Vocoders have many parameters that allow researchers to answer questions about cochlear-implant processing in ways that overcome some logistical complications of controlling for factors in individual cochlear implant users. However, there is such a large variety in the implementation of vocoders that the term "vocoder" is not specific enough to describe the signal processing used in these experiments. Misunderstanding vocoder parameters can result in experimental confounds or unexpected stimulus distortions. This paper highlights the signal processing parameters that should be specified when describing vocoder construction. The paper also provides guidance on how to determine vocoder parameters within perception experiments, given the experimenter's goals and research questions, to avoid common signal processing mistakes. Throughout, we will assume that experimenters are interested in vocoders with the specific goal of better understanding cochlear implants.
Collapse
Affiliation(s)
- Margaret Cychosz
- Department of Linguistics, University of California, Los Angeles, Los Angeles, California 90095, USA
| | - Matthew B Winn
- Department of Speech-Language-Hearing Sciences, University of Minnesota, Minneapolis, Minnesota 55455, USA
| | - Matthew J Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, College Park, Maryland 20742, USA
| |
Collapse
|
2
|
Quass GL, Kral A. Tripolar configuration and pulse shape in cochlear implants reduce channel interactions in the temporal domain. Hear Res 2024; 443:108953. [PMID: 38277881 DOI: 10.1016/j.heares.2024.108953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/08/2024] [Accepted: 01/11/2024] [Indexed: 01/28/2024]
Abstract
The present study investigates effects of current focusing and pulse shape on threshold, dynamic range, spread of excitation and channel interaction in the time domain using cochlear implant stimulation. The study was performed on 20 adult guinea pigs using a 6-channel animal cochlear implant, recording was performed in the auditory midbrain using a multielectrode array. After determining the best frequencies for individual recording contacts with acoustic stimulation, the ear was deafened and a cochlear implant was inserted into the cochlea. The position of the implant was controlled by x-ray. Stimulation with biphasic, pseudomonophasic and monophasic stimuli was performed with monopolar, monopolar with common ground, bipolar and tripolar configuration in two sets of experiments, allowing comparison of the effects of the different stimulation strategies on threshold, dynamic range, spread of excitation and channel interaction. Channel interaction was studied in the temporal domain, where two electrodes were activated with pulse trains and phase locking to these pulse trains in the midbrain was quantified. The results documented multifactorial influences on the response properties, with significant interaction between factors. Thresholds increased with increasing current focusing, but decreased with pseudomonophasic and monophasic pulse shapes. The results documented that current focusing, particularly tripolar configuration, effectively reduces channel interaction, but that also pseudomonophasic and monophasic stimulation and phase duration intensity coding reduce channel interactions.
Collapse
Affiliation(s)
- Gunnar L Quass
- Institute for AudioNeuroTechnology (VIANNA) & Department of Experimental Otology, Otolaryngology Clinics, Hannover Medical School, Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177), Germany.
| | - Andrej Kral
- Institute for AudioNeuroTechnology (VIANNA) & Department of Experimental Otology, Otolaryngology Clinics, Hannover Medical School, Hannover, Germany; Cluster of Excellence "Hearing4All" (EXC 2177), Germany; Australian Hearing Hub, School of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
3
|
Mu H, Smith D, Ng SH, Anand V, Le NHA, Dharmavarapu R, Khajehsaeidimahabadi Z, Richardson RT, Ruther P, Stoddart PR, Gricius H, Baravykas T, Gailevičius D, Seniutinas G, Katkus T, Juodkazis S. Fraxicon for Optical Applications with Aperture ∼1 mm: Characterisation Study. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:287. [PMID: 38334558 PMCID: PMC10856946 DOI: 10.3390/nano14030287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Revised: 12/19/2023] [Accepted: 01/22/2024] [Indexed: 02/10/2024]
Abstract
Emerging applications of optical technologies are driving the development of miniaturised light sources, which in turn require the fabrication of matching micro-optical elements with sub-1 mm cross-sections and high optical quality. This is particularly challenging for spatially constrained biomedical applications where reduced dimensionality is required, such as endoscopy, optogenetics, or optical implants. Planarisation of a lens by the Fresnel lens approach was adapted for a conical lens (axicon) and was made by direct femtosecond 780 nm/100 fs laser writing in the SZ2080™ polymer with a photo-initiator. Optical characterisation of the positive and negative fraxicons is presented. Numerical modelling of fraxicon optical performance under illumination by incoherent and spatially extended light sources is compared with the ideal case of plane-wave illumination. Considering the potential for rapid replication in soft polymers and resists, this approach holds great promise for the most demanding technological applications.
Collapse
Affiliation(s)
- Haoran Mu
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
| | - Daniel Smith
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
| | - Soon Hock Ng
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
- Melbourne Centre for Nanofabrication, Australian National Fabrication Facility, Clayton, VIC 3168, Australia
| | - Vijayakumar Anand
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
- Institute of Physics, University of Tartu, W. Ostwaldi 1, 50411 Tartu, Estonia
| | - Nguyen Hoai An Le
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
| | - Raghu Dharmavarapu
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
| | - Zahra Khajehsaeidimahabadi
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
| | - Rachael T. Richardson
- Bionics Institute, East Melbourne, VIC 3002, Australia;
- Medical Bionics Department, University of Melbourne, Fitzroy, VIC 3065, Australia
| | - Patrick Ruther
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg im Breisgau, Germany;
- BrainLinks-BrainTools Center, University of Freiburg, 79110 Freiburg im Breisgau, Germany
| | - Paul R. Stoddart
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
| | - Henrikas Gricius
- Laser Research Center, Physics Faculty, Vilnius University, Sauletekio Ave. 10, 10223 Vilnius, Lithuania; (H.G.); (D.G.)
| | | | - Darius Gailevičius
- Laser Research Center, Physics Faculty, Vilnius University, Sauletekio Ave. 10, 10223 Vilnius, Lithuania; (H.G.); (D.G.)
| | - Gediminas Seniutinas
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
- Melbourne Centre for Nanofabrication, Australian National Fabrication Facility, Clayton, VIC 3168, Australia
| | - Tomas Katkus
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
| | - Saulius Juodkazis
- Optical Sciences Centre, ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), Swinburne University of Technology, Hawthorn, VIC 3122, Australia; (H.M.); (D.S.); (N.H.A.L.); (R.D.); (Z.K.); (P.R.S.); (G.S.); (T.K.); (S.J.)
- Laser Research Center, Physics Faculty, Vilnius University, Sauletekio Ave. 10, 10223 Vilnius, Lithuania; (H.G.); (D.G.)
- WRH Program International Research Frontiers Initiative (IRFI) Tokyo Institute of Technology, Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan
| |
Collapse
|
4
|
Azees AA, Thompson AC, Thomas R, Zhou J, Ruther P, Wise AK, Ajay EA, Garrett DJ, Quigley A, Fallon JB, Richardson RT. Spread of activation and interaction between channels with multi-channel optogenetic stimulation in the mouse cochlea. Hear Res 2023; 440:108911. [PMID: 37977051 DOI: 10.1016/j.heares.2023.108911] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 10/19/2023] [Accepted: 11/02/2023] [Indexed: 11/19/2023]
Abstract
For individuals with severe to profound hearing loss resulting from irreversibly damaged hair cells, cochlear implants can be used to restore hearing by delivering electrical stimulation directly to the spiral ganglion neurons. However, current spread lowers the spatial resolution of neural activation. Since light can be easily confined, optogenetics is a technique that has the potential to improve the precision of neural activation, whereby visible light is used to stimulate neurons that are modified with light-sensitive opsins. This study compares the spread of neural activity across the inferior colliculus of the auditory midbrain during electrical and optical stimulation in the cochlea of acutely deafened mice with opsin-modified spiral ganglion neurons (H134R variant of the channelrhodopsin-2). Monopolar electrical stimulation was delivered via each of four 0.2 mm wide platinum electrode rings at 0.6 mm centre-to-centre spacing, whereas 453 nm wavelength light was delivered via each of five 0.22 × 0.27 mm micro-light emitting diodes (LEDs) at 0.52 mm centre-to-centre spacing. Channel interactions were also quantified by threshold changes during simultaneous stimulation by pairs of electrodes or micro-LEDs at different distances between the electrodes (0.6, 1.2 and 1.8 mm) or micro-LEDs (0.52, 1.04, 1.56 and 2.08 mm). The spread of activation resulting from single channel optical stimulation was approximately half that of monopolar electrical stimulation as measured at two levels of discrimination above threshold (p<0.001), whereas there was no significant difference between optical stimulation in opsin-modified deafened mice and pure tone acoustic stimulation in normal-hearing mice. During simultaneous micro-LED stimulation, there were minimal channel interactions for all micro-LED spacings tested. For neighbouring micro-LEDs/electrodes, the relative influence on threshold was 13-fold less for optical stimulation compared electrical stimulation (p<0.05). The outcomes of this study show that the higher spatial precision of optogenetic stimulation results in reduced channel interaction compared to electrical stimulation, which could increase the number of independent channels in a cochlear implant. Increased spatial resolution and the ability to activate more than one channel simultaneously could lead to better speech perception in cochlear implant recipients.
Collapse
Affiliation(s)
- Ajmal A Azees
- The Bionics Institute, East Melbourne, VIC 3002, Australia; Department of Electrical and Biomedical Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Alex C Thompson
- The Bionics Institute, East Melbourne, VIC 3002, Australia; Medical Bionics Department, University of Melbourne, East Melbourne, VIC, Australia
| | - Ross Thomas
- The Bionics Institute, East Melbourne, VIC 3002, Australia
| | - Jenny Zhou
- The Bionics Institute, East Melbourne, VIC 3002, Australia
| | - Patrick Ruther
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg 79110, Germany; BrainLinks-BrainTools Center, University of Freiburg, Freiburg 79110, Germany
| | - Andrew K Wise
- The Bionics Institute, East Melbourne, VIC 3002, Australia; Department of Surgery (Otolaryngology), University of Melbourne, Melbourne, VIC 3002, Australia; Medical Bionics Department, University of Melbourne, East Melbourne, VIC, Australia
| | - Elise A Ajay
- The Bionics Institute, East Melbourne, VIC 3002, Australia; Faculty of Engineering and Information Technology, University of Melbourne, Melbourne, VIC, Australia
| | - David J Garrett
- Department of Electrical and Biomedical Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Anita Quigley
- Department of Electrical and Biomedical Engineering, RMIT University, Melbourne, VIC 3000, Australia; Department of Medicine, University of Melbourne, St Vincent's Hospital, Melbourne, VIC 3065, Australia; The Aikenhead Centre for Medical Discovery, St Vincent's Hospital, Melbourne, VIC 3065, Australia
| | - James B Fallon
- The Bionics Institute, East Melbourne, VIC 3002, Australia; Department of Surgery (Otolaryngology), University of Melbourne, Melbourne, VIC 3002, Australia; Medical Bionics Department, University of Melbourne, East Melbourne, VIC, Australia
| | - Rachael T Richardson
- The Bionics Institute, East Melbourne, VIC 3002, Australia; Department of Surgery (Otolaryngology), University of Melbourne, Melbourne, VIC 3002, Australia; Medical Bionics Department, University of Melbourne, East Melbourne, VIC, Australia.
| |
Collapse
|
5
|
Khurana L, Harczos T, Moser T, Jablonski L. En route to sound coding strategies for optical cochlear implants. iScience 2023; 26:107725. [PMID: 37720089 PMCID: PMC10502376 DOI: 10.1016/j.isci.2023.107725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/19/2023] Open
Abstract
Hearing loss is the most common human sensory deficit. Severe-to-complete sensorineural hearing loss is often treated by electrical cochlear implants (eCIs) bypassing dysfunctional or lost hair cells by direct stimulation of the auditory nerve. The wide current spread from each intracochlear electrode array contact activates large sets of tonotopically organized neurons limiting spectral selectivity of sound coding. Despite many efforts, an increase in the number of independent eCI stimulation channels seems impossible to achieve. Light, which can be better confined in space than electric current may help optical cochlear implants (oCIs) to overcome eCI shortcomings. In this review, we present the current state of the optogenetic sound encoding. We highlight optical sound coding strategy development capitalizing on the optical stimulation that requires fine-grained, fast, and power-efficient real-time sound processing controlling dozens of microscale optical emitters as an emerging research area.
Collapse
Affiliation(s)
- Lakshay Khurana
- Institute for Auditory Neuroscience, University Medical Center Göttingen, Göttingen, Germany
- Auditory Neuroscience and Optogenetics Laboratory, German Primate Center, Göttingen, Germany
- Auditory Neuroscience and Synaptic Nanophysiology Group, Max-Planck-Institute for Multidisciplinary Sciences, Göttingen, Germany
- Junior Research Group “Computational Neuroscience and Neuroengineering”, Göttingen, Germany
- The Doctoral Program “Sensory and Motor Neuroscience”, Göttingen Graduate Center for Neurosciences, Biophysics, and Molecular Biosciences (GGNB), Göttingen, Germany
- InnerEarLab, University Medical Center Göttingen, Göttingen, Germany
| | - Tamas Harczos
- Institute for Auditory Neuroscience, University Medical Center Göttingen, Göttingen, Germany
- Auditory Neuroscience and Optogenetics Laboratory, German Primate Center, Göttingen, Germany
| | - Tobias Moser
- Institute for Auditory Neuroscience, University Medical Center Göttingen, Göttingen, Germany
- Auditory Neuroscience and Optogenetics Laboratory, German Primate Center, Göttingen, Germany
- Auditory Neuroscience and Synaptic Nanophysiology Group, Max-Planck-Institute for Multidisciplinary Sciences, Göttingen, Germany
- InnerEarLab, University Medical Center Göttingen, Göttingen, Germany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Göttingen, Germany
| | - Lukasz Jablonski
- Institute for Auditory Neuroscience, University Medical Center Göttingen, Göttingen, Germany
- Auditory Neuroscience and Optogenetics Laboratory, German Primate Center, Göttingen, Germany
- Junior Research Group “Computational Neuroscience and Neuroengineering”, Göttingen, Germany
- InnerEarLab, University Medical Center Göttingen, Göttingen, Germany
| |
Collapse
|
6
|
Wagner L, Plontke SK, Rahne T. An analysis of the spread of electric field within the cochlea for different devices including custom-made electrodes for subtotal cochleoectomy. PLoS One 2023; 18:e0287216. [PMID: 37682960 PMCID: PMC10490913 DOI: 10.1371/journal.pone.0287216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 06/01/2023] [Indexed: 09/10/2023] Open
Abstract
OBJECTIVE Cochlear implants (CIs) can restore hearing not only in patients with profound hearing loss and deafness, but also in patients following tumour removal of intra-cochlear schwannomas. In such cases, design and placement differ from conventional electrode insertion, in which the cochlea remains filled with fluid. Despite these technical and surgical differences, previous studies have tended to show positive results in speech perception in tumour patients. The purpose of this study is to retrospectively evaluate the ability to predict speech recognition outcomes using individual electric field spreads and to investigate worldwide unique tumour cases. STUDY DESIGN In a retrospective analysis in a university tertiary center electric field spreads were compared between two groups of electrode designs implanted between 2009 and 2020 i.e., between lateral wall electrodes and custom-made perimodiolar electrode carriers from the same company. The voltage gradients were analysed and grouped with speech recognition results. RESULTS Differences in electrical field spreads were found between lateral wall electrodes and the custom-made perimodiolar electrodes, whereas a significant influence of electric fields on scores in speech recognition cannot be demonstrated. CONCLUSION Prediction of speech recognition outcome based on electric field propagation results seems not feasible. Significant differences in field spread between electrode arrays can be clearly demonstrated. This observation and its relevance to hearing treatment and speech recognition should therefore be further investigated in upcoming studies.
Collapse
Affiliation(s)
- Luise Wagner
- Department of Otorhinolaryngology and Halle Hearing and Implant Center, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Stefan K. Plontke
- Department of Otorhinolaryngology and Halle Hearing and Implant Center, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Torsten Rahne
- Department of Otorhinolaryngology and Halle Hearing and Implant Center, Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| |
Collapse
|
7
|
Gilbert Z, Mason X, Sebastian R, Tang AM, Martin Del Campo-Vera R, Chen KH, Leonor A, Shao A, Tabarsi E, Chung R, Sundaram S, Kammen A, Cavaleri J, Gogia AS, Heck C, Nune G, Liu CY, Kellis SS, Lee B. A review of neurophysiological effects and efficiency of waveform parameters in deep brain stimulation. Clin Neurophysiol 2023; 152:93-111. [PMID: 37208270 DOI: 10.1016/j.clinph.2023.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 02/09/2023] [Accepted: 04/15/2023] [Indexed: 05/21/2023]
Abstract
Neurostimulation has diverse clinical applications and potential as a treatment for medically refractory movement disorders, epilepsy, and other neurological disorders. However, the parameters used to program electrodes-polarity, pulse width, amplitude, and frequency-and how they are adjusted have remained largely untouched since the 1970 s. This review summarizes the state-of-the-art in Deep Brain Stimulation (DBS) and highlights the need for further research to uncover the physiological mechanisms of neurostimulation. We focus on studies that reveal the potential for clinicians to use waveform parameters to selectively stimulate neural tissue for therapeutic benefit, while avoiding activating tissue associated with adverse effects. DBS uses cathodic monophasic rectangular pulses with passive recharging in clinical practice to treat neurological conditions such as Parkinson's Disease. However, research has shown that stimulation efficiency can be improved, and side effects reduced, through modulating parameters and adding novel waveform properties. These developments can prolong implantable pulse generator lifespan, reducing costs and surgery-associated risks. Waveform parameters can stimulate neurons based on axon orientation and intrinsic structural properties, providing clinicians with more precise targeting of neural pathways. These findings could expand the spectrum of diseases treatable with neuromodulation and improve patient outcomes.
Collapse
Affiliation(s)
- Zachary Gilbert
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States.
| | - Xenos Mason
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Rinu Sebastian
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Austin M Tang
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Roberto Martin Del Campo-Vera
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Kuang-Hsuan Chen
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Andrea Leonor
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Arthur Shao
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Emiliano Tabarsi
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Ryan Chung
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Shivani Sundaram
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Alexandra Kammen
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Jonathan Cavaleri
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Angad S Gogia
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Christi Heck
- Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - George Nune
- Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Charles Y Liu
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Spencer S Kellis
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Brian Lee
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| |
Collapse
|
8
|
van Groesen NRA, Briaire JJ, de Jong MAM, Frijns JHM. Dynamic Current Focusing Compared to Monopolar Stimulation in a Take-Home Trial of Cochlear Implant Users. Ear Hear 2023; 44:306-317. [PMID: 36279119 DOI: 10.1097/aud.0000000000001282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVES This study compared the performance of a dynamic partial tripolar cochlear implant speech encoding strategy termed dynamic current focusing (DCF) to monopolar stimulation (MP) using spectro-temporal, temporal, and speech-in-noise recognition testing. DESIGN DCF is a strategy that utilizes tripolar or high partial tripolar stimulation at threshold level and increases loudness by slowly widening current spread towards most comfortable level. Thirteen cochlear implant users were fitted with DCF and a non-steered MP matched on pulse rate, pulse width, and active electrodes. Nine participants completed the single-blinded within-subject crossover trial. Repeated testing consisted of four sessions. Strategies were allocated in a DCF-MP-DCF-MP or MP-DCF-MP-DCF design. Three-week adaptation periods ended with a test session in which speech-in-noise recognition (matrix speech-in-noise sentence test), spectro-temporal ripple tests (SMRT and STRIPES) and a temporal amplitude modulation detection test were conducted. All participants recorded their subjective experiences with both strategies using the Speech, Spatial and Qualities of Hearing Scale questionnaire. RESULTS Participants' SMRT thresholds improved 0.40 ripples per octave ( p = 0.02, Bonferroni-corrected: p = 0.1) with DCF over MP at 65 dB SPL. No significant differences between the strategies were found on speech-in-noise recognition at conversational (65 dB SPL) and soft (45 dB SPL) loudness levels, temporal testing, STRIPES, or the SMRT at 45 dB SPL. After Bonferroni correction, a learning effect remained on the matrix speech-in-noise sentence test at both loudness levels (65 dB SPL: p = 0.01; 45 dB SPL: p = 0.02). There was no difference in learning effects over time between DCF and MP. Similarly, no significant differences were found in subjective experience on the Speech, Spatial and Qualities of Hearing Scale questionnaire. DCF reduced average battery life by 48% (5.1 hours) ( p < 0.001) compared to MP. CONCLUSIONS DCF may improve spectral resolution over MP at comfortable loudness (65 dB SPL) in cochlear implant users. However, the evidence collected in this study was weak and the significant result disappeared after Bonferroni correction. Also, not all spectral tests revealed this improvement. As expected, battery life was reduced for DCF. Although the current study is limited by its small sample size, considering previous studies, DCF does not consistently improve speech recognition in noise over MP strategies.
Collapse
Affiliation(s)
| | - Jeroen Johannes Briaire
- Otorhinolaryngology and Head and Neck Surgery, Leiden University Medical Center, Leiden, the Netherlands
| | - Monique Anna Maria de Jong
- Otorhinolaryngology and Head and Neck Surgery, Leiden University Medical Center, Leiden, the Netherlands
| | - Johannes Hubertus Maria Frijns
- Otorhinolaryngology and Head and Neck Surgery, Leiden University Medical Center, Leiden, the Netherlands
- Leiden Institute for Brain and Cognition, Leiden, the Netherlands
| |
Collapse
|
9
|
Bratu EL, Sunderhaus LW, Berg KA, Dwyer RT, Labadie RF, Gifford RH, Noble JH. Activation region overlap visualization for image-guided cochlear implant programming. Biomed Phys Eng Express 2022; 9:10.1088/2057-1976/ac9aba. [PMID: 36594887 PMCID: PMC10072294 DOI: 10.1088/2057-1976/ac9aba] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 10/17/2022] [Indexed: 11/24/2022]
Abstract
Objective. The cochlear implant is a neural prosthesis designed to directly stimulate auditory nerve fibers to induce the sensation of hearing in those experiencing severe-to-profound hearing loss. After surgical implantation, audiologists program the implant's external processor with settings intended to produce optimal hearing outcomes. The likelihood of achieving optimal outcomes increases when audiologists have access to tools that objectively present information related to the patient's own anatomy and surgical outcomes. This includes visualizations like the one presented here, termed the activation region overlap image, which is designed to decrease subjectivity when determining amounts of overlapping stimulation between implant electrodes.Approach. This visualization uses estimates of electric field strength to indicate spread of neural excitation due to each electrode. Unlike prior visualizations, this method explicitly defines regions of nerves receiving substantial stimulation from each electrode to help clinicians assess the presence of significant overlapping stimulation. A multi-reviewer study compared this and an existing technique on the consistency, efficiency, and optimality of plans generated from each method. Statistical significance was evaluated using the two-sided Wilcoxon rank sum test.Main results. The study showed statistically significant improvements in consistency (p < 10-12), efficiency (p < 10-15), and optimality (p < 10-5) when generating plans using the proposed method versus the existing method.Significance. This visualization addresses subjectivity in assessing overlapping stimulation between implant electrodes, which currently relies on reviewer estimates. The results of the evaluation indicate the provision of such objective information during programming sessions would likely benefit clinicians in making programming decisions.
Collapse
Affiliation(s)
- Erin L. Bratu
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, TN, USA
| | - Linsey W. Sunderhaus
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Katelyn A. Berg
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Robert T. Dwyer
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Robert F. Labadie
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - René H. Gifford
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Jack H. Noble
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, TN, USA
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
- Vanderbilt University Medical Center, Department of Otolaryngology – Head & Neck Surgery, Nashville, TN, USA
| |
Collapse
|
10
|
Hayashida Y, Kameda S, Umehira Y, Ishikawa S, Yagi T. Multichannel stimulation module as a tool for animal studies on cortical neural prostheses. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:927581. [PMID: 36176924 PMCID: PMC9513350 DOI: 10.3389/fmedt.2022.927581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Accepted: 08/08/2022] [Indexed: 11/13/2022] Open
Abstract
Intracortical microstimulation to the visual cortex is thought to be a feasible technique for inducing localized phosphenes in patients with acquired blindness, and thereby for visual prosthesis. In order to design effective stimuli for the prosthesis, it is important to elucidate relationships between the spatio-temporal patterns of stimuli and the resulting neural responses and phosphenes through pre-clinical animal studies. However, the physiological basis of effective spatial patterns of the stimuli for the prosthesis has been little investigated in the literature, at least partly because that the previously developed multi-channel stimulation systems were designed specifically for the clinical use. In the present, a 64-channel stimulation module was developed as a scalable tool for animal experiments. The operations of the module were verified by not only dry-bench tests but also physiological animal experiments in vivo. The results demonstrated its usefulness for examining the stimulus-response relationships in a quantitative manner, and for inducing the multi-site neural excitations with a multi-electrode array. In addition, this stimulation module could be used to generate spatially patterned stimuli with up to 4,096 channels in a dynamic way, in which the stimulus patterns can be updated at a certain frame rate in accordance with the incoming visual scene. The present study demonstrated that our stimulation module is applicable to the physiological and other future studies in animals on the cortical prostheses.
Collapse
Affiliation(s)
- Yuki Hayashida
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
- Department of Information Engineering, Graduate School of Engineering, Mie University, Tsu, Japan
| | - Seiji Kameda
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
| | - Yuichi Umehira
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
| | - Shinnosuke Ishikawa
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
| | - Tetsuya Yagi
- Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, Suita, Japan
- Department of Electrical and Electronic Engineering, School of Engineering, Fukui University of Technology, Fukui, Japan
| |
Collapse
|
11
|
Sarreal RRS, Blake DT, Bhatti PT. Development and Characterization of a Micromagnetic Alternative to Cochlear Implant Electrode Arrays. IEEE Trans Neural Syst Rehabil Eng 2022; 30:2116-2125. [PMID: 35905064 DOI: 10.1109/tnsre.2022.3193342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
To stimulate the auditory nerve, cochlear implants directly inject electrical current into surrounding tissue via an implanted electrode array. While many cochlear implant users achieve strong speech perception scores, there remains significant variability. Since cochlear implant electrode arrays are surrounded by a conductive fluid, perilymph, a spread of excitation occurs. The functionality of the cochlea is spatially dependent, and a wider area of excitation negatively affects the hearing of the user. Importantly, magnetic fields are unaffected by the material properties of biological components. To utilize the electromagnetic properties of the human ear, a microcoil array was developed. The microcoils are 4-turn solenoids with a 250-μm turn radius and a 31.75-μm wire radius, coated with Parylene-C. The efficient design was implemented to accelerate testing. The obtained results describe stimulation capabilities. Functionality was validated using a frequency response analyzer to measure how the generated electromagnetic power radiates in space. 99.8% power loss was observed over a 100-μm separation between a pair of identical microcoils. Obtained through finite-element modeling, the microcoils can be driven by a 60 mA, 5 kHz, sinusoidal input for 10 minutes before predicted inflammation. Rattay's activating function was calculated to evaluate the magnetic stimulation effect of external fields on target neurons. Combined with the frequency response analysis, magnitude and spatial effects of the generated potential is established. As a result, each microcoil requires a 400-μm-wide area for each independent stimulation channel, which is 84% narrower than a commercial cochlear array channel, thereby suggesting greater spatial selectivity.
Collapse
|
12
|
Illg A, Lenarz T. Cochlear Implantation in Hearing-Impaired Elderly: Clinical Challenges and Opportunities to Optimize Outcome. Front Neurosci 2022; 16:887719. [PMID: 35903809 PMCID: PMC9315238 DOI: 10.3389/fnins.2022.887719] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 06/14/2022] [Indexed: 11/13/2022] Open
Abstract
Cochlear implant (CI) overall provides a very good outcome, but speech comprehension outcome in the elderly is more variable. Several clinical factors play an important role. The management of residual hearing, the presence of comorbidities, and especially the progression of cognitive decline seem to be the clinical parameters that strongly determine the outcome of cochlear implantation and need to be discussed prospectively in the consultation process with the elderly hearing impaired. In the context of this review article, strategies for dealing with these will be discussed. Timely cochlear implantation should already be considered by hearing aid acousticians or practicing otolaryngologists and communicated or initiated with the patient. This requires intensive cooperation between hearing aid acousticians and experts in the clinic. In addition, residual hearing and comorbidities in the elderly need to be considered to make realistic predictions about speech comprehension with CI. Long-term aftercare and its different implementations should be discussed preoperatively, so that the elderly person with hearing impairments feels well taken care of together with his or her relatives. Elderly patients with hearing impairments benefit most from a CI in terms of speech comprehension if there is a large cochlear coverage (electrical or acoustic electrical) and the therapy is not hampered by comorbidities, especially cognitive decline.
Collapse
|
13
|
Recent Advances in Cochlear Implant Electrode Array Design Parameters. MICROMACHINES 2022; 13:mi13071081. [PMID: 35888898 PMCID: PMC9323156 DOI: 10.3390/mi13071081] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 06/29/2022] [Accepted: 06/30/2022] [Indexed: 02/04/2023]
Abstract
Cochlear implants are neural implant devices that aim to restore hearing in patients with severe sensorineural hearing impairment. Here, the main goal is to successfully place the electrode array in the cochlea to stimulate the auditory nerves through bypassing damaged hair cells. Several electrode and electrode array parameters affect the success of this technique, but, undoubtedly, the most important one is related to electrodes, which are used for nerve stimulation. In this paper, we provide a comprehensive resource on the electrodes currently being used in cochlear implant devices. Electrode materials, shape, and the effect of spacing between electrodes on the stimulation, stiffness, and flexibility of electrode-carrying arrays are discussed. The use of sensors and the electrical, mechanical, and electrochemical properties of electrode arrays are examined. A large library of preferred electrodes is reviewed, and recent progress in electrode design parameters is analyzed. Finally, the limitations and challenges of the current technology are discussed along with a proposal of future directions in the field.
Collapse
|
14
|
Abstract
Cochlear implants have been the most successful neural prosthesis, with one million users globally. Researchers used the source-filter model and speech vocoder to design the modern multi-channel implants, allowing implantees to achieve 70%-80% correct sentence recognition in quiet, on average. Researchers also used the cochlear implant to help understand basic mechanisms underlying loudness, pitch, and cortical plasticity. While front-end processing advances improved speech recognition in noise, the unilateral implant speech recognition in quiet has plateaued since the early 1990s. This lack of progress calls for action on re-designing the cochlear stimulating interface and collaboration with the general neurotechnology community.
Collapse
Affiliation(s)
- Fan-Gang Zeng
- Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology-Head and Neck Surgery and Center for Hearing Research, University of California, 110 Medical Sciences E, Irvine, California 92697, USA
| |
Collapse
|
15
|
Abstract
INTRODUCTION More than 5% of the world's population have a disabling hearing loss which can be managed by hearing aids or implanted electrical devices. However, outcomes are highly variable, and the sound perceived by recipients is far from perfect. Sparked by the discovery of progenitor cells in the cochlea and rapid progress in drug delivery to the cochlea, biological and pharmaceutical therapies are currently in development to improve the function of the cochlear implant or eliminate the need for it altogether. AREAS COVERED This review highlights progress in emerging regenerative strategies to restore hearing and adjunct therapies to augment the cochlear implant. Novel approaches include the reprogramming of progenitor cells to restore the sensory hair cell population in the cochlea, gene therapy and gene editing to treat hereditary and acquired hearing loss. A detailed review of optogenetics is also presented as a technique that could enable optical stimulation of the spiral ganglion neurons, replacing or complementing electrical stimulation. EXPERT OPINION Increasing evidence of substantial reversal of hearing loss in animal models, alongside rapid advances in delivery strategies to the cochlea and learnings from clinical trials will amalgamate into a biological or pharmaceutical therapy to replace or complement the cochlear implant.
Collapse
Affiliation(s)
- Elise Ajay
- Bionics Institute, East Melbourne, Victoria, Australia.,University of Melbourne, Department of Engineering
| | | | - Rachael Richardson
- Bionics Institute, East Melbourne, Victoria, Australia.,University of Melbourne, Medical Bionics Department, Parkville, Victoria, Australia.,University of Melbourne, Department of Surgery (Otolaryngology), East Melbourne, Victoria, Australia
| |
Collapse
|
16
|
Veugen LCE, van Opstal AJ, van Wanrooij MM. Reaction Time Sensitivity to Spectrotemporal Modulations of Sound. Trends Hear 2022; 26:23312165221127589. [PMID: 36172759 PMCID: PMC9523861 DOI: 10.1177/23312165221127589] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
We tested whether sensitivity to acoustic spectrotemporal modulations can be observed from reaction times for normal-hearing and impaired-hearing conditions. In a manual reaction-time task, normal-hearing listeners had to detect the onset of a ripple (with density between 0–8 cycles/octave and a fixed modulation depth of 50%), that moved up or down the log-frequency axis at constant velocity (between 0–64 Hz), in an otherwise-unmodulated broadband white-noise. Spectral and temporal modulations elicited band-pass filtered sensitivity characteristics, with fastest detection rates around 1 cycle/oct and 32 Hz for normal-hearing conditions. These results closely resemble data from other studies that typically used the modulation-depth threshold as a sensitivity criterion. To simulate hearing-impairment, stimuli were processed with a 6-channel cochlear-implant vocoder, and a hearing-aid simulation that introduced separate spectral smearing and low-pass filtering. Reaction times were always much slower compared to normal hearing, especially for the highest spectral densities. Binaural performance was predicted well by the benchmark race model of binaural independence, which models statistical facilitation of independent monaural channels. For the impaired-hearing simulations this implied a “best-of-both-worlds” principle in which the listeners relied on the hearing-aid ear to detect spectral modulations, and on the cochlear-implant ear for temporal-modulation detection. Although singular-value decomposition indicated that the joint spectrotemporal sensitivity matrix could be largely reconstructed from independent temporal and spectral sensitivity functions, in line with time-spectrum separability, a substantial inseparable spectral-temporal interaction was present in all hearing conditions. These results suggest that the reaction-time task yields a valid and effective objective measure of acoustic spectrotemporal-modulation sensitivity.
Collapse
Affiliation(s)
- Lidwien C E Veugen
- Department of Biophysics, Donders Institute for Brain, Cognition and Behavior, 6029Radboud University, Nijmegen, Netherlands
| | - A John van Opstal
- Department of Biophysics, Donders Institute for Brain, Cognition and Behavior, 6029Radboud University, Nijmegen, Netherlands
| | - Marc M van Wanrooij
- Department of Biophysics, Donders Institute for Brain, Cognition and Behavior, 6029Radboud University, Nijmegen, Netherlands
| |
Collapse
|
17
|
Wagner L, Altindal R, Plontke SK, Rahne T. Pure tone discrimination with cochlear implants and filter-band spread. Sci Rep 2021; 11:20236. [PMID: 34642437 PMCID: PMC8511217 DOI: 10.1038/s41598-021-99799-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 09/22/2021] [Indexed: 11/09/2022] Open
Abstract
For many cochlear implant (CI) users, frequency discrimination is still challenging. We studied the effect of frequency differences relative to the electrode frequency bands on pure tone discrimination. A single-center, prospective, controlled, psychoacoustic exploratory study was conducted in a tertiary university referral center. Thirty-four patients with Cochlear Ltd. and MED-EL CIs and 19 age-matched normal-hearing control subjects were included. Two sinusoidal tones were presented with varying frequency differences. The reference tone frequency was chosen according to the center frequency of basal or apical electrodes. Discrimination abilities were psychophysically measured in a three-interval, two-alternative, forced-choice procedure (3I-2AFC) for various CI electrodes. Hit rates were measured, particularly with respect to discrimination abilities at the corner frequency of the electrode frequency-bands. The mean rate of correct decision concerning pitch difference was about 60% for CI users and about 90% for the normal-hearing control group. In CI users, the difference limen was two semitones, while normal-hearing participants detected the difference of one semitone. No influence of the corner frequency of the CI electrodes was found. In CI users, pure tone discrimination seems to be independent of tone positions relative to the corner frequency of the electrode frequency-band. Differences of 2 semitones can be distinguished within one electrode.
Collapse
Affiliation(s)
- Luise Wagner
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Halle (Saale), Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany. .,Universitätsklinikum Halle (Saale), HNO-Klinik, Ernst-Grube-Str. 40, 06120, Halle (Saale), Germany.
| | - Reyhan Altindal
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Halle (Saale), Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Stefan K Plontke
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Halle (Saale), Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| | - Torsten Rahne
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Halle (Saale), Martin-Luther-University Halle-Wittenberg, Halle (Saale), Germany
| |
Collapse
|
18
|
Cochlear Implantation in Elderly Patients with Residual Hearing. J Clin Med 2021; 10:jcm10194305. [PMID: 34640325 PMCID: PMC8509733 DOI: 10.3390/jcm10194305] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/20/2021] [Accepted: 09/21/2021] [Indexed: 11/30/2022] Open
Abstract
This retrospective study aimed to investigate the range of hearing levels in a cochlear implant (CI) elderly population receiving electric-acoustic-stimulation (EAS) or electric-stimulation (ES) alone. The investigation evaluates the degree of hearing preservation (HP) and the speech comprehension resulting from EAS or ES-only to identify audiometric factors that predict adequate EAS and ES use. We analyzed the pure tone audiometry and speech perception in quiet and noise preoperatively and 12-months after activation of 89 elderly adults (age of 65 years old or older), yielding in total 97 CIs. Thirty-two (33.1%) patients were potential EAS candidates preoperatively, of which 18 patients used EAS at the time of first fitting and the other 14 patients continued to use their residual hearing for EAS at 12-months. Post-treatment, patients with EAS system and ES-only users’ with longer electrodes showed better results in monosyllable word scores in quiet than ES-only users with shorter electrodes. A similar trend was revealed for the speech recognition in noise. Patients with an EAS system benefit from maintaining their natural residual hearing. Nevertheless, strict preoperative patient selection is warranted particularly in elderly patients, in whom the hearing thresholds for EAS indication differ slightly from that in younger adults.
Collapse
|
19
|
Keshmiri Neghab H, Soheilifar MH, Grusch M, Ortega MM, Esmaeeli Djavid G, Saboury AA, Goliaei B. The state of the art of biomedical applications of optogenetics. Lasers Surg Med 2021; 54:202-216. [PMID: 34363230 DOI: 10.1002/lsm.23463] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 07/08/2021] [Accepted: 07/23/2021] [Indexed: 12/31/2022]
Abstract
BACKGROUND AND OBJECTIVE Optogenetics has opened new insights into biomedical research with the ability to manipulate and control cellular activity using light in combination with genetically engineered photosensitive proteins. By stimulating with light, this method provides high spatiotemporal and high specificity resolution, which is in contrast to conventional pharmacological or electrical stimulation. Optogenetics was initially introduced to control neural activities but was gradually extended to other biomedical fields. STUDY DESIGN In this paper, firstly, we summarize the current optogenetic tools stimulated by different light sources, including lasers, light-emitting diodes, and laser diodes. Second, we outline the variety of biomedical applications of optogenetics not only for neuronal circuits but also for various kinds of cells and tissues from cardiomyocytes to ganglion cells. Furthermore, we highlight the potential of this technique for treating neurological disorders, cardiac arrhythmia, visual impairment, hearing loss, and urinary bladder diseases as well as clarify the mechanisms underlying cancer progression and control of stem cell differentiation. CONCLUSION We sought to summarize the various types of promising applications of optogenetics to treat a broad spectrum of disorders. It is conceivable to expect that optogenetics profits a growing number of patients suffering from a range of different diseases in the near future.
Collapse
Affiliation(s)
- Hoda Keshmiri Neghab
- Department of Photo Healing and Regeneration, Medical Laser Research Center, Yara Institute, ACECR, Tehran, Iran
| | | | - Michael Grusch
- Department of Medicine I, Institute of Cancer Research, Medical University of Vienna, Vienna, Austria
| | - Manoela Marques Ortega
- Laboratory of Cell and Molecular Tumor Biology and Bioactive Compounds, São Francisco University, Bragança Paulista, São Paulo, Brazil
| | - Gholamreza Esmaeeli Djavid
- Department of Photo Healing and Regeneration, Medical Laser Research Center, Yara Institute, ACECR, Tehran, Iran
| | - Ali Akbar Saboury
- Department of Biophysics, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
| | - Bahram Goliaei
- Department of Biophysics, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran
| |
Collapse
|
20
|
Jahn KN, Arenberg JG. Electrophysiological Estimates of the Electrode-Neuron Interface Differ Between Younger and Older Listeners With Cochlear Implants. Ear Hear 2021; 41:948-960. [PMID: 32032228 PMCID: PMC10424265 DOI: 10.1097/aud.0000000000000827] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The primary objective of this study was to quantify differences in evoked potential correlates of spiral ganglion neuron (SGN) density between younger and older individuals with cochlear implants (CIs) using the electrically evoked compound action potential (ECAP). In human temporal bone studies and in animal models, SGN density is the lowest in older subjects and in those who experienced long durations of deafness during life. SGN density also varies as a function of age at implantation and hearing loss etiology. Taken together, it is likely that younger listeners who were deafened and implanted during childhood have denser populations of SGNs than older individuals who were deafened and implanted later in life. In animals, ECAP amplitudes, amplitude growth function (AGF) slopes, and their sensitivity to stimulus interphase gap (IPG) are predictive of SGN density. The authors hypothesized that younger listeners who were deafened and implanted as children would demonstrate larger ECAP amplitudes, steeper AGF slopes, and greater IPG sensitivity than older, adult-deafened and implanted listeners. DESIGN Data were obtained from 22 implanted ears (18 individuals). Thirteen ears (9 individuals) were deafened and implanted as children (child-implanted group), and nine ears (9 individuals) were deafened and implanted as adults (adult-implanted group). The groups differed significantly on a number of demographic variables that are implicitly related to SGN density: (1) chronological age; (2) age at implantation; and (3) duration of preimplantation hearing loss. ECAP amplitudes, AGF linear slopes, and thresholds were assessed on a subset of electrodes in each ear in response to two IPGs (7 and 30 µsec). Speech recognition was assessed using a medial vowel identification task. RESULTS Compared with the adult-implanted listeners, individuals in the child-implanted group demonstrated larger changes in ECAP amplitude when the IPG of the stimulus was increased from 7 to 30 µsec (i.e., greater IPG sensitivity). On average, child-implanted participants also had larger ECAP amplitudes and steeper AGF linear slopes than the adult-implanted participants, irrespective of IPG. IPG sensitivity for AGF linear slope and ECAP threshold did not differ between age groups. Vowel recognition performance was not correlated with any of the ECAP measures assessed in this study. CONCLUSIONS The results of this study support the theory that young CI listeners who were deafened and implanted during childhood may have denser neural populations than older listeners who were deafened and implanted as adults. Potential between-group differences in SGN integrity emphasize a need to investigate optimized CI programming parameters for younger and older listeners.
Collapse
Affiliation(s)
- Kelly N. Jahn
- Department of Otolaryngology – Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles St., Boston, MA 02114, USA
| | - Julie G. Arenberg
- Department of Otolaryngology – Head and Neck Surgery, Harvard Medical School, Boston, MA 02114, USA
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles St., Boston, MA 02114, USA
| |
Collapse
|
21
|
Viral-mediated transduction of auditory neurons with opsins for optical and hybrid activation. Sci Rep 2021; 11:11229. [PMID: 34045604 PMCID: PMC8160204 DOI: 10.1038/s41598-021-90764-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 05/13/2021] [Indexed: 12/15/2022] Open
Abstract
Optical stimulation is a paradigm-shifting approach to modulating neural activity that has the potential to overcome the issue of current spread that occurs with electrical stimulation by providing focused stimuli. But optical stimulation either requires high power infrared light or genetic modification of neurons to make them responsive to lower power visible light. This work examines optical activation of auditory neurons following optogenetic modification via AAV injection in two species (mouse and guinea pig). An Anc80 viral vector was used to express the channelrhodopsin variant ChR2-H134R fused to a fluorescent reporter gene under the control of the human synapsin-1 promoter. The AAV was administered directly to the cochlea (n = 33) or posterior semi-circular canal of C57BL/6 mice (n = 4) or to guinea pig cochleae (n = 6). Light (488 nm), electrical stimuli or the combination of these (hybrid stimulation) was delivered to the cochlea via a laser-coupled optical fibre and co-located platinum wire. Activation thresholds, spread of activation and stimulus interactions were obtained from multi-unit recordings from the central nucleus of the inferior colliculus of injected mice, as well as ChR2-H134R transgenic mice (n = 4). Expression of ChR2-H134R was examined by histology. In the mouse, transduction of auditory neurons by the Anc80 viral vector was most successful when injected at a neonatal age with up to 89% of neurons transduced. Auditory neuron transductions were not successful in guinea pigs. Inferior colliculus responses to optical stimuli were detected in a cochleotopic manner in all mice with ChR2-H134R expression. There was a significant correlation between lower activation thresholds in mice and higher proportions of transduced neurons. There was no difference in spread of activation between optical stimulation and electrical stimulation provided by the light/electrical delivery system used here (optical fibre with bonded 25 µm platinum/iridium wire). Hybrid stimulation, comprised of sub-threshold optical stimulation to 'prime' or raise the excitability of the neurons, lowered the threshold for electrical activation in most cases, but the impact on excitation width was more variable compared to transgenic mice. This study demonstrates the impact of opsin expression levels and expression pattern on optical and hybrid stimulation when considering optical or hybrid stimulation techniques for neuromodulation.
Collapse
|
22
|
The effect of increased channel interaction on speech perception with cochlear implants. Sci Rep 2021; 11:10383. [PMID: 34001987 PMCID: PMC8128897 DOI: 10.1038/s41598-021-89932-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Accepted: 04/29/2021] [Indexed: 11/30/2022] Open
Abstract
Cochlear implants (CIs) are neuroprostheses that partially restore hearing for people with severe-to-profound hearing loss. While CIs can provide good speech perception in quiet listening situations for many, they fail to do so in environments with interfering sounds for most listeners. Previous research suggests that this is due to detrimental interaction effects between CI electrode channels, limiting their function to convey frequency-specific information, but evidence is still scarce. In this study, an experimental manipulation called spectral blurring was used to increase channel interaction in CI listeners using Advanced Bionics devices with HiFocus 1J and MS electrode arrays to directly investigate its causal effect on speech perception. Instead of using a single electrode per channel as in standard CI processing, spectral blurring used up to 6 electrodes per channel simultaneously to increase the overlap between adjacent frequency channels as would occur in cases with severe channel interaction. Results demonstrated that this manipulation significantly degraded CI speech perception in quiet by 15% and speech reception thresholds in babble noise by 5 dB when all channels were blurred by a factor of 6. Importantly, when channel interaction was increased just on a subset of electrodes, speech scores were mostly unaffected and were only significantly degraded when the 5 most apical channels were blurred. These apical channels convey information up to 1 kHz at the apical end of the electrode array and are typically located at angular insertion depths of about 250 up to 500°. These results confirm and extend earlier findings indicating that CI speech perception may not benefit from deactivating individual channels along the array and that efforts should instead be directed towards reducing channel interaction per se and in particular for the most-apical electrodes. Hereby, causal methods such as spectral blurring could be used in future research to control channel interaction effects within listeners for evaluating compensation strategies.
Collapse
|
23
|
Reduced Spread of Electric Field After Surgical Removal of Intracochlear Schwannoma and Cochlear Implantation. Otol Neurotol 2021; 41:e1297-e1303. [PMID: 33492805 DOI: 10.1097/mao.0000000000002884] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE The primary aim of the study was to explore whether reduced spread of electrical field is observed after partial or subtotal cochleoectomy and cochlear implantation compared with standard cochlear implantation. Secondarily, the influence on speech perception was explored comparing both groups. STUDY DESIGN Nonconcurrent cohort study. SETTING Monocentric study at a tertiary referral center. PATIENTS Twenty adult cochlear implant (CI) users after tumor resection with cochleoectomy of varying extent and 20 electrode-matched CI users with standard electrode insertion. INTERVENTIONS Partial and subtotal cochleoectomy for tumor removal and CI. OUTCOME MEASURES Trans-impedance, electrically evoked compound action potentials, and word recognition were measured. Relative impedance was computed as a function of distance between the stimulation and recording electrode. RESULTS Trans-impedance was smaller and more homogeneous in patients with partial or subtotal cochleoectomy than in the control group. In the tumor group, the mean relative impedance decreased to 0.20 (standard deviation [SD] = 0.03) at a distance of 1 electrode and to 0.25 (SD = 0.04) in the control group. After excluding seven patients with a second tumor in the internal auditory canal or cerebellopontine angle, with transmodiolar tumors, after near total cochleoectomy, or only extended cochleostomy, word recognition was 61% (SD = 19%) at 3 months and 75% (SD = 19%) at 12 months after activation of the audio processor in the tumor group. At 12 months, it was significantly (p < 0.05) better than in the control group (3 mo: 45%, SD = 25%; 12 mo: 53%, SD = 26%). A smaller trans-impedance is associated with a better word recognition. CONCLUSION We conclude that the surgical technique used for CI surgery after subtotal cochleoectomy reduces the spread of the electric field and overcomes the potential drawbacks in structure preservation associated with that technique.
Collapse
|
24
|
Abstract
When nerves are damaged by trauma or disease, they are still capable of firing off electrical command signals that originate from the brain. Furthermore, those damaged nerves have an innate ability to partially regenerate, so they can heal from trauma and even reinnervate new muscle targets. For an amputee who has his/her damaged nerves surgically reconstructed, the electrical signals that are generated by the reinnervated muscle tissue can be sensed and interpreted with bioelectronics to control assistive devices or robotic prostheses. No two amputees will have identical physiologies because there are many surgical options for reconstructing residual limbs, which may in turn impact how well someone can interface with a robotic prosthesis later on. In this review, we aim to investigate what the literature has to say about different pathways for peripheral nerve regeneration and how each pathway can impact the neuromuscular tissue’s final electrophysiology. This information is important because it can guide us in planning the development of future bioelectronic devices, such as prosthetic limbs or neurostimulators. Future devices will primarily have to interface with tissue that has undergone some natural regeneration process, and so we have explored and reported here what is known about the bioelectrical features of neuromuscular tissue regeneration.
Collapse
|
25
|
Spitzer ER, Galvin JJ, Friedmann DR, Landsberger DM. Melodic interval perception with acoustic and electric hearing in bimodal and single-sided deaf cochlear implant listeners. Hear Res 2021; 400:108136. [PMID: 33310263 PMCID: PMC7796925 DOI: 10.1016/j.heares.2020.108136] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Revised: 11/20/2020] [Accepted: 11/24/2020] [Indexed: 10/22/2022]
Abstract
Two notes sounded sequentially elicit melodic intervals and contours that form the basis of melody. Many previous studies have characterized pitch perception in cochlear implant (CI) users to be poor which may be due to the limited spectro-temporal resolution and/or spectral warping with electric hearing compared to acoustic hearing (AH). Poor pitch perception in CIs has been shown to distort melodic interval perception. To characterize this interval distortion, we recruited CI users with either normal (single sided deafness, SSD) or limited (bimodal) AH in the non-implanted ear. The contralateral AH allowed for a stable reference with which to compare melodic interval perception in the CI ear, within the same listener. Melodic interval perception was compared across acoustic and electric hearing in 9 CI listeners (4 bimodal and 5 SSD). Participants were asked to rank the size of a probe interval presented to the CI ear to a reference interval presented to the contralateral AH ear using a method of constant stimuli. Ipsilateral interval ranking was also measured within the AH ear to ensure that listeners understood the task and that interval ranking was stable and accurate within AH. Stimuli were delivered to the AH ear via headphones and to the CI ear via direct audio input (DAI) to participants' clinical processors. During testing, a reference and probe interval was presented and participants indicated which was larger. Ten comparisons for each reference-probe combination were presented. Psychometric functions were fit to the data to determine the probe interval size that matched the reference interval. Across all AH reference intervals, the mean matched CI interval was 1.74 times larger than the AH reference. However, there was great inter-subject variability. For some participants, CI interval distortion varied across different reference AH intervals; for others, CI interval distortion was constant. Within the AH ear, ipsilateral interval ranking was accurate, ensuring that participants understood the task. No significant differences in the patterns of results were observed between bimodal and SSD CI users. The present data show that much larger intervals were needed with the CI to match contralateral AH reference intervals. As such, input melodic patterns are likely to be perceived as frequency compressed and/or warped with electric hearing, with less variation among notes in the pattern. The high inter-subject variability in CI interval distortion suggests that CI signal processing should be optimized for individual CI users.
Collapse
Affiliation(s)
- Emily R Spitzer
- New York University Grossman School of Medicine, Department of Otolaryngology-Head and Neck Surgery, 462 1st Avenue, NBV 5E5, New York 10016, NY, USA.
| | | | - David R Friedmann
- New York University Grossman School of Medicine, Department of Otolaryngology-Head and Neck Surgery, 462 1st Avenue, NBV 5E5, New York 10016, NY, USA
| | - David M Landsberger
- New York University Grossman School of Medicine, Department of Otolaryngology-Head and Neck Surgery, 462 1st Avenue, NBV 5E5, New York 10016, NY, USA
| |
Collapse
|
26
|
Zhou N, Dixon S, Zhu Z, Dong L, Weiner M. Spectrotemporal Modulation Sensitivity in Cochlear-Implant and Normal-Hearing Listeners: Is the Performance Driven by Temporal or Spectral Modulation Sensitivity? Trends Hear 2020; 24:2331216520948385. [PMID: 32895024 PMCID: PMC7482033 DOI: 10.1177/2331216520948385] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
This study examined the contribution of temporal and spectral modulation sensitivity to discrimination of stimuli modulated in both the time and frequency domains. The spectrotemporally modulated stimuli contained spectral ripples that shifted systematically across frequency over time at a repetition rate of 5 Hz. As the ripple density increased in the stimulus, modulation depth of the 5 Hz amplitude modulation (AM) reduced. Spectrotemporal modulation discrimination was compared with subjects’ ability to discriminate static spectral ripples and the ability to detect slow AM. The general pattern from both the cochlear implant (CI) and normal hearing groups showed that spectrotemporal modulation thresholds were correlated more strongly with AM detection than with static ripple discrimination. CI subjects’ spectrotemporal modulation thresholds were also highly correlated with speech recognition in noise, when partialing out static ripple discrimination, but the correlation was not significant when partialing out AM detection. The results indicated that temporal information was more heavily weighted in spectrotemporal modulation discrimination, and for CI subjects, it was AM sensitivity that drove the correlation between spectrotemporal modulation thresholds and speech recognition. The results suggest that for the rates tested here, temporal information processing may limit performance more than spectral information processing in both CI users and normal hearing listeners.
Collapse
Affiliation(s)
- Ning Zhou
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States
| | - Susannah Dixon
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States
| | - Zhen Zhu
- Department of Engineering, East Carolina University, Greenville, North Carolina, United States
| | - Lixue Dong
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States
| | - Marti Weiner
- Department of Communication Sciences and Disorders, East Carolina University, Greenville, North Carolina, United States
| |
Collapse
|
27
|
Thompson AC, Wise AK, Hart WL, Needham K, Fallon JB, Gunewardene N, Stoddart PR, Richardson RT. Hybrid optogenetic and electrical stimulation for greater spatial resolution and temporal fidelity of cochlear activation. J Neural Eng 2020; 17:056046. [PMID: 33036009 DOI: 10.1088/1741-2552/abbff0] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Compared to electrical stimulation, optogenetic stimulation has the potential to improve the spatial precision of neural activation in neuroprostheses, but it requires intense light and has relatively poor temporal kinetics. We tested the effect of hybrid stimulation, which is the combination of subthreshold optical and electrical stimuli, on spectral and temporal fidelity in the cochlea by recording multiunit activity in the inferior colliculus of channelrhodopsin (H134R variant) transgenic mice. APPROACH Pulsed light or biphasic electrical pulses were delivered to cochlear spiral ganglion neurons of acutely deafened mice, either as individual stimuli or as hybrid stimuli for which the timing of the electrical pulse had a varied delay relative to the start of the optical pulse. Response thresholds, spread of activation and entrainment data were obtained from multi-unit recordings from the auditory midbrain. MAIN RESULTS Facilitation occurred when subthreshold electrical stimuli were applied at the end of, or up to 3.75 ms after subthreshold optical pulses. The spread of activation resulting from hybrid stimulation was significantly narrower than electrical-only and optical-only stimulation (p < 0.01), measured at equivalent suprathreshold levels of loudness that are relevant to cochlear implant users. Furthermore, temporal fidelity, measured as maximum following rates to 300 ms pulse trains bursts up to 240 Hz, was 2.4-fold greater than optical-only stimulation (p < 0.05). SIGNIFICANCE By significantly improving spectral resolution of electrical- and optical-only stimulation and the temporal fidelity of optical-only stimulation, hybrid stimulation has the potential to increase the number of perceptually independent stimulating channels in a cochlear implant.
Collapse
|
28
|
Luo X, Wu CC, Pulling K. Combining current focusing and steering in a cochlear implant processing strategy. Int J Audiol 2020; 60:232-237. [PMID: 32967485 DOI: 10.1080/14992027.2020.1822551] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To evaluate the benefit of combined current focusing and steering to speech recognition in noise with cochlear implants (CIs). DESIGN Combined current focusing and steering was implemented using focused partial tripolar (pTP) mode with two current steering ranges. The two pTPsteering strategies were compared to a monopolar (MP) strategy without current focusing or steering and a pTP strategy with only current focusing using the Hearing in Noise Test. The strategies differed only in stimulation mode. STUDY SAMPLE Ten post-lingually deafened adult CI users participated in this study. RESULTS Compared to the MP strategy, both pTPsteering strategies produced significantly better speech reception thresholds, while the pTP strategy did not. Subjects with better baseline MP performance had less improvements with the pTPsteering strategies. All four strategies were experimental low-rate strategies and none of them outperformed subjects' clinical strategies. CONCLUSIONS Speech recognition in noise was better with the pTPsteering strategies than with the MP strategy, but the effect of pTP-mode current steering on spectral resolution is yet to be tested.
Collapse
Affiliation(s)
- Xin Luo
- College of Health Solutions, Arizona State University, Tempe, AZ, USA
| | - Ching-Chih Wu
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, USA
| | - Kathryn Pulling
- College of Health Solutions, Arizona State University, Tempe, AZ, USA
| |
Collapse
|
29
|
Precompensating for spread of excitation in a cochlear implant coding strategy. Hear Res 2020; 395:107977. [PMID: 32653106 DOI: 10.1016/j.heares.2020.107977] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 03/11/2020] [Accepted: 04/15/2020] [Indexed: 11/22/2022]
Abstract
Cochlear implant users' limited ability to understand speech in noisy environments has been linked to the poor spatial resolution and the high degree of spectral smearing associated with the spread of neural excitation. A sound coding algorithm that aims to improve the spectro-temporal representation of the sound signal at the implanted ear by precompensating the electrical stimulation for the spread of excitation is presented in this study. The spread precompensation algorithm was integrated into the standard clinical advanced combination encoder (ACE) strategy and the resulting strategy was called SPACE. SPACE was evaluated acutely with a group of six implant users and was compared to their daily used ACE strategy in terms of preference rating and speech recognition in four-talker babble and stationary speech-shaped noise. While no significant differences in preference rating were observed, speech recognition in four-talker babble was improved by SPACE processing. Analysis of the group results revealed a significant improvement in mean speech reception threshold (SRT) over the ACE strategy of 1.4 dB in four-talker babble, whereas the difference of 0.9 dB in stationary noise did not reach statistical significance. Assessment of individual differences showed that four out of six listeners obtained significant SRT improvements with SPACE and that no subject scored significantly worse compared to ACE. The results suggest that the proposed sound coding strategy has the potential to improve speech perception for cochlear implant users in challenging listening situations.
Collapse
|
30
|
Dieter A, Klein E, Keppeler D, Jablonski L, Harczos T, Hoch G, Rankovic V, Paul O, Jeschke M, Ruther P, Moser T. μLED-based optical cochlear implants for spectrally selective activation of the auditory nerve. EMBO Mol Med 2020; 12:e12387. [PMID: 32596983 PMCID: PMC7411546 DOI: 10.15252/emmm.202012387] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 05/23/2020] [Accepted: 06/02/2020] [Indexed: 01/19/2023] Open
Abstract
Electrical cochlear implants (eCIs) partially restore hearing and enable speech comprehension to more than half a million users, thereby re-connecting deaf patients to the auditory scene surrounding them. Yet, eCIs suffer from limited spectral selectivity, resulting from current spread around each electrode contact and causing poor speech recognition in the presence of background noise. Optogenetic stimulation of the auditory nerve might overcome this limitation as light can be conveniently confined in space. Here, we combined virus-mediated optogenetic manipulation of cochlear spiral ganglion neurons (SGNs) and microsystems engineering to establish acute multi-channel optical cochlear implant (oCI) stimulation in adult Mongolian gerbils. oCIs based on 16 microscale thin-film light-emitting diodes (μLEDs) evoked tonotopic activation of the auditory pathway with high spectral selectivity and modest power requirements in hearing and deaf gerbils. These results prove the feasibility of μLED-based oCIs for spectrally selective activation of the auditory nerve.
Collapse
Affiliation(s)
- Alexander Dieter
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
- Göttingen Graduate School for Neurosciences and Molecular BiosciencesUniversity of GöttingenGöttingenGermany
- Present address:
Synaptic Wiring LabCenter for Molecular Neurobiology HamburgUniversity Medical Center Hamburg‐EppendorfHamburgGermany
| | - Eric Klein
- Department of Microsystems Engineering (IMTEK)University of FreiburgFreiburgGermany
| | - Daniel Keppeler
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
| | - Lukasz Jablonski
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
- Auditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
| | - Tamas Harczos
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
- Auditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
| | - Gerhard Hoch
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
- Auditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
| | - Vladan Rankovic
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
- Auditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
- Restorative Cochlear Genomics GroupAuditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
| | - Oliver Paul
- Department of Microsystems Engineering (IMTEK)University of FreiburgFreiburgGermany
- BrainLinks‐BrainToolsCluster of ExcellenceUniversity of FreiburgFreiburgGermany
| | - Marcus Jeschke
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
- Auditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
- Cognitive Hearing in Primates GroupAuditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
| | - Patrick Ruther
- Department of Microsystems Engineering (IMTEK)University of FreiburgFreiburgGermany
- BrainLinks‐BrainToolsCluster of ExcellenceUniversity of FreiburgFreiburgGermany
| | - Tobias Moser
- Institute for Auditory Neuroscience and InnerEarLabUniversity Medical Center GöttingenGöttingenGermany
- Göttingen Graduate School for Neurosciences and Molecular BiosciencesUniversity of GöttingenGöttingenGermany
- Auditory Neuroscience and Optogenetics LaboratoryGerman Primate CenterGöttingenGermany
- Auditory Neuroscience GroupMax Planck Institute for Experimental MedicineGöttingenGermany
- Cluster of Excellence “Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC)University of GoettingenGoettingenGermany
| |
Collapse
|
31
|
Goehring T, Arenberg JG, Carlyon RP. Using Spectral Blurring to Assess Effects of Channel Interaction on Speech-in-Noise Perception with Cochlear Implants. J Assoc Res Otolaryngol 2020; 21:353-371. [PMID: 32519088 PMCID: PMC7445227 DOI: 10.1007/s10162-020-00758-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Accepted: 05/21/2020] [Indexed: 01/07/2023] Open
Abstract
Cochlear implant (CI) listeners struggle to understand speech in background noise. Interactions between electrode channels due to current spread increase the masking of speech by noise and lead to difficulties with speech perception. Strategies that reduce channel interaction therefore have the potential to improve speech-in-noise perception by CI listeners, but previous results have been mixed. We investigated the effects of channel interaction on speech-in-noise perception and its association with spectro-temporal acuity in a listening study with 12 experienced CI users. Instead of attempting to reduce channel interaction, we introduced spectral blurring to simulate some of the effects of channel interaction by adjusting the overlap between electrode channels at the input level of the analysis filters or at the output by using several simultaneously stimulated electrodes per channel. We measured speech reception thresholds in noise as a function of the amount of blurring applied to either all 15 electrode channels or to 5 evenly spaced channels. Performance remained roughly constant as the amount of blurring applied to all channels increased up to some knee point, above which it deteriorated. This knee point differed across listeners in a way that correlated with performance on a non-speech spectro-temporal task, and is proposed here as an individual measure of channel interaction. Surprisingly, even extreme amounts of blurring applied to 5 channels did not affect performance. The effects on speech perception in noise were similar for blurring at the input and at the output of the CI. The results are in line with the assumption that experienced CI users can make use of a limited number of effective channels of information and tolerate some deviations from their everyday settings when identifying speech in the presence of a masker. Furthermore, these findings may explain the mixed results by strategies that optimized or deactivated a small number of electrodes evenly distributed along the array by showing that blurring or deactivating one-third of the electrodes did not harm speech-in-noise performance.
Collapse
Affiliation(s)
- Tobias Goehring
- Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK.
| | - Julie G Arenberg
- Massachusetts Eye and Ear, Harvard Medical School, 243 Charles St, Boston, MA, 02114, USA
| | - Robert P Carlyon
- Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, 15 Chaucer Road, Cambridge, CB2 7EF, UK
| |
Collapse
|
32
|
Moser T, Dieter A. Towards optogenetic approaches for hearing restoration. Biochem Biophys Res Commun 2020; 527:337-342. [DOI: 10.1016/j.bbrc.2019.12.126] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Accepted: 12/23/2019] [Indexed: 01/06/2023]
|
33
|
Zhou H, Wang N, Zheng N, Yu G, Meng Q. A New Approach for Noise Suppression in Cochlear Implants: A Single-Channel Noise Reduction Algorithm. Front Neurosci 2020; 14:301. [PMID: 32372902 PMCID: PMC7186595 DOI: 10.3389/fnins.2020.00301] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Accepted: 03/16/2020] [Indexed: 12/11/2022] Open
Abstract
The cochlea “translates” the in-air vibrational acoustic “language” into the spikes of neural “language” that are then transmitted to the brain for auditory understanding and/or perception. During this intracochlear “translation” process, high resolution in time–frequency–intensity domains guarantees the high quality of the input neural information for the brain, which is vital for our outstanding hearing abilities. However, cochlear implants (CIs) have coarse artificial coding and interfaces, and CI users experience more challenges in common acoustic environments than their normal-hearing (NH) peers. Noise from sound sources that a listener has no interest in may be neglected by NH listeners, but they may distract a CI user. We discuss the CI noise-suppression techniques and introduce noise management for a new implant system. The monaural signal-to-noise ratio estimation-based noise suppression algorithm “eVoice,” which is incorporated in the processors of Nurotron® EnduroTM, was evaluated in two speech perception experiments. The results show that speech intelligibility in stationary speech-shaped noise can be significantly improved with eVoice. Similar results have been observed in other CI devices with single-channel noise reduction techniques. Specifically, the mean speech reception threshold decrease in the present study was 2.2 dB. The Nurotron society already has more than 10,000 users, and eVoice is a start for noise management in the new system. Future steps on non-stationary-noise suppression, spatial-source separation, bilateral hearing, microphone configuration, and environment specification are warranted. The existing evidence, including our research, suggests that noise-suppression techniques should be applied in CI systems. The artificial hearing of CI listeners requires more advanced signal processing techniques to reduce brain effort and increase intelligibility in noisy settings.
Collapse
Affiliation(s)
- Huali Zhou
- Acoustics Lab, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China
| | | | - Nengheng Zheng
- The Guangdong Key Laboratory of Intelligent Information Processing, College of Electronics and Information Engineering, Shenzhen University, Shenzhen, China
| | - Guangzheng Yu
- Acoustics Lab, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China
| | - Qinglin Meng
- Acoustics Lab, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China
| |
Collapse
|
34
|
Kleinlogel S, Vogl C, Jeschke M, Neef J, Moser T. Emerging approaches for restoration of hearing and vision. Physiol Rev 2020; 100:1467-1525. [DOI: 10.1152/physrev.00035.2019] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Impairments of vision and hearing are highly prevalent conditions limiting the quality of life and presenting a major socioeconomic burden. For long, retinal and cochlear disorders have remained intractable for causal therapies, with sensory rehabilitation limited to glasses, hearing aids, and electrical cochlear or retinal implants. Recently, the application of gene therapy and optogenetics to eye and ear has generated hope for a fundamental improvement of vision and hearing restoration. To date, one gene therapy for the restoration of vision has been approved and undergoing clinical trials will broaden its application including gene replacement, genome editing, and regenerative approaches. Moreover, optogenetics, i.e. controlling the activity of cells by light, offers a more general alternative strategy. Over little more than a decade, optogenetic approaches have been developed and applied to better understand the function of biological systems, while protein engineers have identified and designed new opsin variants with desired physiological features. Considering potential clinical applications of optogenetics, the spotlight is on the sensory systems. Multiple efforts have been undertaken to restore lost or hampered function in eye and ear. Optogenetic stimulation promises to overcome fundamental shortcomings of electrical stimulation, namely poor spatial resolution and cellular specificity, and accordingly to deliver more detailed sensory information. This review aims at providing a comprehensive reference on current gene therapeutic and optogenetic research relevant to the restoration of hearing and vision. We will introduce gene-therapeutic approaches and discuss the biotechnological and optoelectronic aspects of optogenetic hearing and vision restoration.
Collapse
Affiliation(s)
| | | | | | | | - Tobias Moser
- Institute for Auditory Neuroscience, University Medical Center Goettingen, Germany
| |
Collapse
|
35
|
Assessing Fine-Grained Speech Discrimination in Young Children With Bilateral Cochlear Implants. Otol Neurotol 2020; 40:e191-e197. [PMID: 30688756 DOI: 10.1097/mao.0000000000002115] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
HYPOTHESIS Children of 2 to 3 years old with cochlear implants can perform consonant discriminations using fine-grained acoustic cues. BACKGROUND Children born with severe-to-profound deafness are provided with early cochlear implantation (<2 yr) to maximize oral communication outcomes. Little is known regarding their abilities to discriminate consonant contrasts for accurately identifying speech sounds. METHODS Using a Reaching for Sound paradigm to collect behavioral responses, consonant contrast discrimination was measured in 13 children with bilateral cochlear implants (BiCIs; aged 28-37 mo), and 13 age-matched normal-hearing (NH) children. Four contrast pairs were tested: 1) place + voicing, 2) place, 3) voicing, and 4) reduced voice-onset-time cue. Using standard processing strategies, electrodograms showing pulsatile stimulation patterns were created retrospectively to assess the spectral-temporal cues delivered through the clinical speech processors. RESULTS As a group, children with BiCIs were able to discriminate all consonant contrasts at a level that was above chance, but their performance was poorer than NH children. Larger individual variability in discrimination performance was found in children with BiCIs. Stepwise regression revealed that, in the place contrast, chronological age was correlated with improved discrimination performance among children with BiCIs. CONCLUSION Children with BiCIs were able to discriminate consonant contrasts using fine-grained spectral-temporal cues above chance level but more poorly than their NH peers. Electrodogram analysis confirmed the access to spectral-temporal cues in the consonant contrasts through clinical speech processors. However, the cue saliency might not have be enough for children with BiCIs to achieve the same discrimination accuracy as NH children.
Collapse
|
36
|
Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant Users. J Assoc Res Otolaryngol 2020; 21:89-104. [PMID: 32020417 DOI: 10.1007/s10162-020-00742-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Accepted: 01/16/2020] [Indexed: 12/19/2022] Open
Abstract
Cochlear implant (CI) performance varies dramatically between subjects. Although the causes of this variability remain unclear, the electrode-neuron interface is thought to play an important role. Here we evaluate the contribution of two parameters of this interface on the perception of CI listeners: the electrode-to-modiolar wall distance (EMD), estimated from cone-beam computed tomography (CT) scans, and a measure of neural health. Since there is no objective way to quantify neural health in CI users, we measure stimulus polarity sensitivity, which is assumed to be related to neural degeneration, and investigate whether it also correlates with subjects' performance in speech recognition and spectro-temporal modulation detection tasks. Detection thresholds were measured in fifteen CI users (sixteen ears) for partial-tripolar triphasic pulses having an anodic or a cathodic central phase. The polarity effect was defined as the difference in threshold between cathodic and anodic stimuli. Our results show that both the EMD and the polarity effect correlate with detection thresholds, both across and within subjects, although the within-subject correlations were weak. Furthermore, the mean polarity effect, averaged across all electrodes for each subject, was negatively correlated with performance on a spectro-temporal modulation detection task. In other words, lower cathodic thresholds were associated with better spectro-temporal modulation detection performance, which is also consistent with polarity sensitivity being a marker of neural degeneration. Implications for the design of future subject-specific fitting strategies are discussed.
Collapse
|
37
|
Reducing Simulated Channel Interaction Reveals Differences in Phoneme Identification Between Children and Adults With Normal Hearing. Ear Hear 2019; 40:295-311. [PMID: 29927780 DOI: 10.1097/aud.0000000000000615] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Channel interaction, the stimulation of overlapping populations of auditory neurons by distinct cochlear implant (CI) channels, likely limits the speech perception performance of CI users. This study examined the role of vocoder-simulated channel interaction in the ability of children with normal hearing (cNH) and adults with normal hearing (aNH) to recognize spectrally degraded speech. The primary aim was to determine the interaction between number of processing channels and degree of simulated channel interaction on phoneme identification performance as a function of age for cNH and to relate those findings to aNH and to CI users. DESIGN Medial vowel and consonant identification of cNH (age 8-17 years) and young aNH were assessed under six (for children) or nine (for adults) different conditions of spectral degradation. Stimuli were processed using a noise-band vocoder with 8, 12, and 15 channels and synthesis filter slopes of 15 (aNH only), 30, and 60 dB/octave (all NH subjects). Steeper filter slopes (larger numbers) simulated less electrical current spread and, therefore, less channel interaction. Spectrally degraded performance of the NH listeners was also compared with the unprocessed phoneme identification of school-aged children and adults with CIs. RESULTS Spectrally degraded phoneme identification improved as a function of age for cNH. For vowel recognition, cNH exhibited an interaction between the number of processing channels and vocoder filter slope, whereas aNH did not. Specifically, for cNH, increasing the number of processing channels only improved vowel identification in the steepest filter slope condition. Additionally, cNH were more sensitive to changes in filter slope. As the filter slopes increased, cNH continued to receive vowel identification benefit beyond where aNH performance plateaued or reached ceiling. For all NH participants, consonant identification improved with increasing filter slopes but was unaffected by the number of processing channels. Although cNH made more phoneme identification errors overall, their phoneme error patterns were similar to aNH. Furthermore, consonant identification of adults with CI was comparable to aNH listening to simulations with shallow filter slopes (15 dB/octave). Vowel identification of earlier-implanted pediatric ears was better than that of later-implanted ears and more comparable to cNH listening in conditions with steep filter slopes (60 dB/octave). CONCLUSIONS Recognition of spectrally degraded phonemes improved when simulated channel interaction was reduced, particularly for children. cNH showed an interaction between number of processing channels and filter slope for vowel identification. The differences observed between cNH and aNH suggest that identification of spectrally degraded phonemes continues to improve through adolescence and that children may benefit from reduced channel interaction beyond where adult performance has plateaued. Comparison to CI users suggests that early implantation may facilitate development of better phoneme discrimination.
Collapse
|
38
|
Guest DR, Oxenham AJ. The role of pitch and harmonic cancellation when listening to speech in harmonic background sounds. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:3011. [PMID: 31153349 PMCID: PMC6529328 DOI: 10.1121/1.5102169] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 04/16/2019] [Accepted: 04/19/2019] [Indexed: 05/29/2023]
Abstract
Fundamental frequency differences (ΔF0) between competing talkers aid in the perceptual segregation of the talkers (ΔF0 benefit), but the underlying mechanisms remain incompletely understood. A model of ΔF0 benefit based on harmonic cancellation proposes that a masker's periodicity can be used to cancel (i.e., filter out) its neural representation. Earlier work suggested that an octave ΔF0 provided little benefit, an effect predicted by harmonic cancellation due to the shared periodicity of masker and target. Alternatively, this effect can be explained by spectral overlap between the harmonic components of the target and masker. To assess these competing explanations, speech intelligibility of a monotonized target talker, masked by a speech-shaped harmonic complex tone, was measured as a function of ΔF0, masker spectrum (all harmonics or odd harmonics only), and masker temporal envelope (amplitude modulated or unmodulated). Removal of the masker's even harmonics when the target was one octave above the masker improved speech reception thresholds by about 5 dB. Because this manipulation eliminated spectral overlap between target and masker components but preserved shared periodicity, the finding is consistent with the explanation for the lack of ΔF0 benefit at the octave based on spectral overlap, but not with the explanation based on harmonic cancellation.
Collapse
Affiliation(s)
- Daniel R. Guest
- Department of Psychology, University of Minnesota, Minneapolis, Minnesota 55455, USA
| | - Andrew J. Oxenham
- Department of Psychology, University of Minnesota, Minneapolis, Minnesota 55455, USA
| |
Collapse
|
39
|
Zhou N. Longitudinal effect of deactivating stimulation sites based on low-rate thresholds on speech recognition in cochlear implant users. Int J Audiol 2019; 58:587-597. [PMID: 31012771 DOI: 10.1080/14992027.2019.1601779] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Objective: The objective of the current study was to examine the longitudinal effect of deactivating stimulation sites estimated to produce broad neural excitation on speech recognition. Design: Spatial patterns of neural excitation were estimated based on a previously established psychophysical measure, that is, detection threshold for low-rate pulse trains. Stimulation sites with relatively poor thresholds were deactivated in an experimental map. The acute effect was evaluated, in quiet and in noise, immediately after the experimental map was created (baseline), after the subjects practiced with the experimental map for two months (treatment), and after the subjects' daily map was switched back again to the clinical map for another two months (withdrawal). Study sample: Eight Cochlear Nucleus device users participated in the study. Results: For both listening in noise and in quiet, the greatest effect of deactivation was observed after the subjects were given time to adapt to the new frequency allocations. The effect was comparable for listening in fluctuating and steady-state noises. All subjects benefited from deactivation for listening in noise, but subjects with greater variability in thresholds were more likely to benefit from deactivation for listening in quiet. Conclusion: The benefit of electrode deactivation for speech recognition can increase with practice.
Collapse
Affiliation(s)
- Ning Zhou
- a Department of Communication Sciences and Disorders , East Carolina University , Greenville , NC , USA
| |
Collapse
|
40
|
Abstract
OBJECTIVES In an attempt to improve spectral resolution and speech intelligibility, several current focusing methods have been proposed to increase spatial selectivity by decreasing intracochlear current spread. For example, tripolar stimulation administers current to a central electrode and uses the two flanking electrodes as the return pathway, creating a narrower intracochlear electrical field and hence increases spectral resolution when compared with monopolar (MP) stimulation. However, more current is required, and in some patients, specifically the ones with high electrode impedances, full loudness growth cannot be supported because of compliance limits. The present study describes and analyses a new loudness encoding approach that uses tripolar stimulation near threshold and gradually broadens the excitation (by decreasing compensation coefficient σ) to increase loudness without the need to increase overall current. It is hypothesized that this dynamic current focusing (DCF) strategy increases spatial selectivity, especially at lower loudness levels, while maintaining maximum selectivity at higher loudness levels, without reaching compliance limits. DESIGN Eleven adult cochlear implant recipients with postlingual hearing loss, with at least 9 months of experience with their HiRes90K implant, were selected to participate in this study. Baseline performance regarding speech intelligibility in noise (Dutch matrix sentence test), spectral ripple discrimination at 45 and 65 dB, and temporal modulation detection thresholds were assessed using their own clinical program, fitted on a Harmony processor. Subsequently, the DCF strategy was fitted on a research Harmony processor. Threshold levels were determined with σ = 0.8, which means 80% of current is returned to the flanking electrodes and the remaining 20% to the extracochlear ground electrode. Instead of increasing overall pulse magnitude, σ was decreased to determine most comfortable loudness. After 2 to 3 hr of adaptation to the research strategy, the same psychophysical measures were taken. RESULTS At 45 dB, average spectral ripple scores improved significantly from 2.4 ripples per octave with their clinical program to 3.74 ripples per octave with the DCF strategy (p = 0.016). Eight out of 11 participants had an improved spectral resolution at 65 dB. Nevertheless, no significant difference between DCF and MP was observed at higher presentation levels. Both speech-in-noise and temporal modulation detection thresholds were equal for MP and DCF strategies. Subjectively, 2 participants preferred the DCF strategy over their own clinical program, 2 preferred their own strategy, while the majority of the participants had no preference. Battery life was decreased and ranged from 1.5 to 4 hr. CONCLUSIONS The DCF strategy gives better spectral resolution, at lower loudness levels, but equal performance on speech tests. These outcomes warrant for a longer adaptation period to study long-term outcomes and evaluate if the outcomes in the ripple tests transfer to the speech scores. Further research, for example, with respect to fitting rules and reduction of power consumption, is necessary to make the DCF strategy suitable for routine clinical application.
Collapse
|
41
|
Abstract
Supplemental Digital Content is available in the text. Objectives: The standard, monopolar (MP) electrode configuration used in commercially available cochlear implants (CI) creates a broad electrical field, which can lead to unwanted channel interactions. Use of more focused configurations, such as tripolar and phased array, has led to mixed results for improving speech understanding. The purpose of the present study was to assess the efficacy of a physiologically inspired configuration called dynamic focusing, using focused tripolar stimulation at low levels and less focused stimulation at high levels. Dynamic focusing may better mimic cochlear excitation patterns in normal acoustic hearing, while reducing the current levels necessary to achieve sufficient loudness at high levels. Design: Twenty postlingually deafened adult CI users participated in the study. Speech perception was assessed in quiet and in a four-talker babble background noise. Speech stimuli were closed-set spondees in noise, and medial vowels at 50 and 60 dB SPL in quiet and in noise. The signal to noise ratio was adjusted individually such that performance was between 40 and 60% correct with the MP strategy. Subjects were fitted with three experimental strategies matched for pulse duration, pulse rate, filter settings, and loudness on a channel-by-channel basis. The strategies included 14 channels programmed in MP, fixed partial tripolar (σ = 0.8), and dynamic partial tripolar (σ at 0.8 at threshold and 0.5 at the most comfortable level). Fifteen minutes of listening experience was provided with each strategy before testing. Sound quality ratings were also obtained. Results: Speech perception performance for vowel identification in quiet at 50 and 60 dB SPL and for spondees in noise was similar for the three tested strategies. However, performance on vowel identification in noise was significantly better for listeners using the dynamic focusing strategy. Sound quality ratings were similar for the three strategies. Some subjects obtained more benefit than others, with some individual differences explained by the relation between loudness growth and the rate of change from focused to broader stimulation. Conclusions: These initial results suggest that further exploration of dynamic focusing is warranted. Specifically, optimizing such strategies on an individual basis may lead to improvements in speech perception for more adult listeners and improve how CIs are tailored. Some listeners may also need a longer period of time to acclimate to a new program.
Collapse
|
42
|
DiNino M, O'Brien G, Bierer SM, Jahn KN, Arenberg JG. The Estimated Electrode-Neuron Interface in Cochlear Implant Listeners Is Different for Early-Implanted Children and Late-Implanted Adults. J Assoc Res Otolaryngol 2019; 20:291-303. [PMID: 30911952 PMCID: PMC6513958 DOI: 10.1007/s10162-019-00716-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2018] [Accepted: 03/03/2019] [Indexed: 12/01/2022] Open
Abstract
Cochlear implant (CI) programming is similar for all CI users despite limited understanding of the electrode-neuron interface (ENI). The ENI refers to the ability of each CI electrode to effectively stimulate target auditory neurons and is influenced by electrode position, neural health, cochlear geometry, and bone and tissue growth in the cochlea. Hearing history likely affects these variables, suggesting that the efficacy of each channel of stimulation differs between children who were implanted at young ages and adults who lost hearing and received a CI later in life. This study examined whether ENI quality differed between early-implanted children and late-implanted adults. Auditory detection thresholds and most comfortable levels (MCLs) were obtained with monopolar and focused electrode configurations. Channel-to-channel variability and dynamic range were calculated for both types of stimulation. Electrical field imaging data were also acquired to estimate levels of intracochlear resistance. Children exhibited lower average auditory perception thresholds and MCLs compared with adults, particularly with focused stimulation. However, neither dynamic range nor channel-to-channel threshold variability differed between groups, suggesting that children’s range of perceptible current was shifted downward. Children also demonstrated increased intracochlear resistance levels relative to the adult group, possibly reflecting greater ossification or tissue growth after CI surgery. These results illustrate physical and perceptual differences related to the ENI of early-implanted children compared with late-implanted adults. Evidence from this study demonstrates a need for further investigation of the ENI in CI users with varying hearing histories.
Collapse
Affiliation(s)
- Mishaela DiNino
- Department of Psychology, Carnegie Mellon University, 5000 Forbes, Ave., Pittsburgh, PA, 15213, USA.
| | - Gabrielle O'Brien
- Department of Speech and Hearing Sciences, University of Washington, 1417 NE 42nd St., Box 354875, Seattle, WA, 98105, USA
| | - Steven M Bierer
- Department of Speech and Hearing Sciences, University of Washington, 1417 NE 42nd St., Box 354875, Seattle, WA, 98105, USA
| | - Kelly N Jahn
- Department of Speech and Hearing Sciences, University of Washington, 1417 NE 42nd St., Box 354875, Seattle, WA, 98105, USA
| | - Julie G Arenberg
- Department of Otolaryngology, Massachusetts Eye and Ear, Harvard Medical School, 243 Charles St., Boston, MA, 02114, USA
| |
Collapse
|
43
|
Croghan NBH, Smith ZM. Speech Understanding With Various Maskers in Cochlear-Implant and Simulated Cochlear-Implant Hearing: Effects of Spectral Resolution and Implications for Masking Release. Trends Hear 2019; 22:2331216518787276. [PMID: 30022730 PMCID: PMC6053854 DOI: 10.1177/2331216518787276] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The purpose of this study was to investigate the relationship between psychophysical spectral resolution and sentence reception in various types of interfering backgrounds for listeners with cochlear implants and normal-hearing subjects listening to vocoded speech. Spectral resolution was measured with a spectral modulation detection (SMD) task. For speech testing, maskers included stationary speech-shaped noise (SSN), four-talker babble, multitone noise, and a competing talker. To explore the possible trade-offs between spectral resolution and susceptibility to different types of maskers, the degree of simulated current spread was varied within the vocoder group, achieving a range of performance for SMD and speech tasks. Greater simulated current spread was detrimental to both spectral resolution and speech recognition, suggesting that interventions that decrease current spread may improve performance for both tasks. Better SMD sensitivity was significantly correlated with improved sentence reception. In addition, differences in sentence reception across the four maskers were significantly associated with SMD across the combined group of cochlear-implant and vocoder subjects. Masking release (MR) was quantified as the signal-to-noise ratio difference in speech reception threshold between the SSN and competing talker. Several individual cochlear-implant subjects demonstrated substantial MR, in contrast to previous studies, and the degree of MR increased with better SMD thresholds across subjects. The results of this study suggest that alternative masker types, particularly competing talkers, are more sensitive than stationary SSN to differences in spectral resolution in the cochlear-implant population.
Collapse
Affiliation(s)
- Naomi B H Croghan
- 1 Denver Research & Technology Labs, Cochlear Ltd., Centennial, CO, USA.,2 Department of Speech, Language, and Hearing Sciences, University of Colorado, Boulder, CO, USA
| | - Zachary M Smith
- 1 Denver Research & Technology Labs, Cochlear Ltd., Centennial, CO, USA.,3 Department of Physiology and Biophysics, School of Medicine, University of Colorado, Aurora, CO, USA
| |
Collapse
|
44
|
Gifford RH, Noble JH, Camarata SM, Sunderhaus LW, Dwyer RT, Dawant BM, Dietrich MS, Labadie RF. The Relationship Between Spectral Modulation Detection and Speech Recognition: Adult Versus Pediatric Cochlear Implant Recipients. Trends Hear 2019; 22:2331216518771176. [PMID: 29716437 PMCID: PMC5949922 DOI: 10.1177/2331216518771176] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Adult cochlear implant (CI) recipients demonstrate a reliable relationship between spectral modulation detection and speech understanding. Prior studies documenting this relationship have focused on postlingually deafened adult CI recipients—leaving an open question regarding the relationship between spectral resolution and speech understanding for adults and children with prelingual onset of deafness. Here, we report CI performance on the measures of speech recognition and spectral modulation detection for 578 CI recipients including 477 postlingual adults, 65 prelingual adults, and 36 prelingual pediatric CI users. The results demonstrated a significant correlation between spectral modulation detection and various measures of speech understanding for 542 adult CI recipients. For 36 pediatric CI recipients, however, there was no significant correlation between spectral modulation detection and speech understanding in quiet or in noise nor was spectral modulation detection significantly correlated with listener age or age at implantation. These findings suggest that pediatric CI recipients might not depend upon spectral resolution for speech understanding in the same manner as adult CI recipients. It is possible that pediatric CI users are making use of different cues, such as those contained within the temporal envelope, to achieve high levels of speech understanding. Further investigation is warranted to investigate the relationship between spectral and temporal resolution and speech recognition to describe the underlying mechanisms driving peripheral auditory processing in pediatric CI users.
Collapse
Affiliation(s)
- René H Gifford
- 1 Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.,2 Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jack H Noble
- 1 Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.,2 Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA.,3 Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA
| | - Stephen M Camarata
- 1 Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Linsey W Sunderhaus
- 1 Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Robert T Dwyer
- 1 Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Benoit M Dawant
- 2 Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA.,3 Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA
| | - Mary S Dietrich
- 4 Department of Biostatistics, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Robert F Labadie
- 2 Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, USA.,3 Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
45
|
Individual Hearing Preservation Cochlear Implantation Using the Concept of Partial Insertion. Otol Neurotol 2019; 40:e326-e335. [DOI: 10.1097/mao.0000000000002127] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
46
|
Litovsky RY, Goupell MJ, Kan A, Landsberger DM. Use of Research Interfaces for Psychophysical Studies With Cochlear-Implant Users. Trends Hear 2019; 21:2331216517736464. [PMID: 29113579 PMCID: PMC5764139 DOI: 10.1177/2331216517736464] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
A growing number of laboratories are using research interfaces to conduct experiments with cochlear-implant (CI) users. Because these interfaces bypass a subject’s clinical sound processor, several concerns exist regarding safety and stimulation levels. Here we suggest best-practice approaches for how to safely and ethically perform this type of research and highlight areas of limited knowledge where further research is needed to help clarify safety limits. The article is designed to provide an introductory level of technical detail about the devices and the effects of electrical stimulation on perception and neurophysiology. From this, we summarize what should be the best practices in the field, based on the literature and our experience. Findings from the review of the literature suggest that there are three main safety concerns: (a) to prevent biological or neural damage, (b) to avoid presentation of uncomfortably loud sounds, and (c) to ensure that subjects have control over stimulus presentation. Researchers must pay close attention to the software–hardware interface to ensure that the three main safety concerns are closely monitored. An important area for future research will be the determination of the amount of biological damage that can occur from electrical stimulation from a CI placed in the cochlea, not in direct contact with neural tissue. As technology used in research with CIs evolve, some of these approaches may change. However, the three main safety principles outlined here are not anticipated to undergo change with technological advances.
Collapse
Affiliation(s)
| | - Matthew J Goupell
- 2 Department of Hearing and Speech Sciences, University of Maryland-College Park, MD, USA
| | - Alan Kan
- 1 University of Wisconsin-Madison, WI, USA
| | | |
Collapse
|
47
|
Xu Y, Xia N, Lim M, Tan X, Tran MH, Boulger E, Peng F, Young H, Rau C, Rack A, Richter CP. Multichannel optrodes for photonic stimulation. NEUROPHOTONICS 2018; 5:045002. [PMID: 30397630 PMCID: PMC6197865 DOI: 10.1117/1.nph.5.4.045002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Accepted: 09/24/2018] [Indexed: 05/27/2023]
Abstract
An emerging method in the field of neural stimulation is the use of photons to activate neurons. The possible advantage of optical stimulation over electrical is attributable to its spatially selective activation of small neuron populations, which is promising in generating superior spatial resolution in neural interfaces. Two principal methods are explored for cochlear prostheses: direct stimulation of nerves with infrared light and optogenetics. This paper discusses basic requirements for developing a light delivery system (LDS) for the cochlea and provides examples for building such devices. The proposed device relies on small optical sources, which are assembled in an array to be inserted into the cochlea. The mechanical properties, the biocompatibility, and the efficacy of optrodes have been tested in animal models. The force required to insert optrodes into a model of the human scala tympani was comparable to insertion forces obtained for contemporary cochlear implant electrodes. Side-emitting diodes are powerful enough to evoke auditory responses in guinea pigs. Chronic implantation of the LDS did not elevate auditory brainstem responses over 26 weeks.
Collapse
Affiliation(s)
- Yingyue Xu
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
- Northwestern University, Department of Communication Sciences and Disorders, Evanston, Illinois, United States
| | - Nan Xia
- Qingdao University, Institute for Digital Medicine and Computer-assisted Surgery, Qingdao, China
| | - Michelle Lim
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Xiaodong Tan
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Minh Ha Tran
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Erin Boulger
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Fei Peng
- Chongqing University, Bioengineering College, Chongqing, China
| | - Hunter Young
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
| | - Christoph Rau
- Diamond Light Source Ltd., Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire, United Kingdom
| | - Alexander Rack
- Structure of Materials Group-ID19, European Synchrotron Radiation Facility, Cedex 9, France
| | - Claus-Peter Richter
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology, Chicago, Illinois, United States
- Northwestern University, Department of Communication Sciences and Disorders, Evanston, Illinois, United States
- Northwestern University, Department of Biomedical Engineering, Evanston, Illinois, United States
- Northwestern University, Hugh Knowles Center for Clinical and Basic Sciences in Hearing, Evanston, Illinois, United States
| |
Collapse
|
48
|
Bareket L, Barriga-Rivera A, Zapf MP, Lovell NH, Suaning GJ. Progress in artificial vision through suprachoroidal retinal implants. J Neural Eng 2018; 14:045002. [PMID: 28541930 DOI: 10.1088/1741-2552/aa6cbb] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Retinal implants have proven their ability to restore visual sensation to people with degenerative retinopathy, characterized by photoreceptor cell death and the retina's inability to sense light. Retinal bionics operate by electrically stimulating the surviving neurons in the retina, thus triggering the transfer of visual sensory information to the brain. Suprachoroidal implants were first investigated in Australia in the 1950s. In this approach, the neuromodulation hardware is positioned between the sclera and the choroid, thus providing significant surgical and safety benefits for patients, with the potential to maintain residual vision combined with the artificial input from the device. Here we review the latest advances and state of the art devices for suprachoroidal prostheses, highlight future technologies and discuss challenges and perspectives towards improved rehabilitation of vision.
Collapse
Affiliation(s)
- Lilach Bareket
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | | | | | | | | |
Collapse
|
49
|
Dai C, Zhao Z, Shen W, Zhang D, Lei G, Qiao Y, Yang S. Evaluation of Mandarin Chinese Speech Recognition in Adults with Cochlear Implants Using the Spectral Ripple Discrimination Test. Med Sci Monit 2018; 24:3557-3563. [PMID: 29806954 PMCID: PMC6001366 DOI: 10.12659/msm.907491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background The aim of this study was to explore the value of the spectral ripple discrimination test in speech recognition evaluation among a deaf (post-lingual) Mandarin-speaking population in China following cochlear implantation. Material/Methods The study included 23 Mandarin-speaking adult subjects with normal hearing (normal-hearing group) and 17 deaf adults who were former Mandarin-speakers, with cochlear implants (cochlear implantation group). The normal-hearing subjects were divided into men (n=10) and women (n=13). The spectral ripple discrimination thresholds between the groups were compared. The correlation between spectral ripple discrimination thresholds and Mandarin speech recognition rates in the cochlear implantation group were studied. Results Spectral ripple discrimination thresholds did not correlate with age (r=−0.19; p=0.22), and there was no significant difference in spectral ripple discrimination thresholds between the male and female groups (p=0.654). Spectral ripple discrimination thresholds of deaf adults with cochlear implants were significantly correlated with monosyllabic recognition rates (r=0.84; p=0.000). Conclusions In a Mandarin Chinese speaking population, spectral ripple discrimination thresholds of normal-hearing individuals were unaffected by both gender and age. Spectral ripple discrimination thresholds were correlated with Mandarin monosyllabic recognition rates of Mandarin-speaking in post-lingual deaf adults with cochlear implants. The spectral ripple discrimination test is a promising method for speech recognition evaluation in adults following cochlear implantation in China.
Collapse
Affiliation(s)
- Chuanfu Dai
- Department of Otolaryngology, Head and Neck Surgery, Beijing Tsinghua Chang Gung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China (mainland).,Department of Otolaryngology, Head and Neck Surgery, Chinese Peoples' Liberation Army General Hospital, Beijing, China (mainland)
| | - Zeqi Zhao
- Institute of Audiology and Balance Science, Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland).,Clinical Hearing Center of Affiliated Hospital, Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| | - Weidong Shen
- Department of Otolaryngology, Head and Neck Surgery, Chinese Peoples' Liberation Army General Hospital, Beijing, China (mainland).,Key Laboratory of Hearing Impairment Science, Chinese Peoples' Liberation Army Medical School, Chinese Ministry of Education, Beijing, China (mainland).,Beijing Key Laboratory of Hearing Impairment Prevention and Treatment, Beijing, China (mainland)
| | - Duo Zhang
- Department of Otolaryngology, Head and Neck Surgery, Chinese Peoples' Liberation Army General Hospital, Beijing, China (mainland).,Key Laboratory of Hearing Impairment Science, Chinese Peoples' Liberation Army Medical School, Chinese Ministry of Education, Beijing, China (mainland).,Beijing Key Laboratory of Hearing Impairment Prevention and Treatment, Beijing, China (mainland)
| | - Guanxiong Lei
- Department of Otolaryngology, Head and Neck Surgery, Chinese Peoples' Liberation Army General Hospital, Beijing, China (mainland).,Key Laboratory of Hearing Impairment Science, Chinese Peoples' Liberation Army Medical School, Chinese Ministry of Education, Beijing, China (mainland).,Beijing Key Laboratory of Hearing Impairment Prevention and Treatment, Beijing, China (mainland)
| | - Yuehua Qiao
- Institute of Audiology and Balance Science, Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland).,Clinical Hearing Center of Affiliated Hospital, Xuzhou Medical University, Xuzhou, Jiangsu, China (mainland)
| | - Shiming Yang
- Department of Otolaryngology, Head and Neck Surgery, Chinese Peoples' Liberation Army General Hospital, Beijing, China (mainland).,Key Laboratory of Hearing Impairment Science, Chinese Peoples' Liberation Army Medical School, Chinese Ministry of Education, Beijing, China (mainland).,Beijing Key Laboratory of Hearing Impairment Prevention and Treatment, Beijing, China (mainland)
| |
Collapse
|
50
|
Lee DH, Aronoff JM. Changing stimulation patterns can change the broadness of contralateral masking functions for bilateral cochlear implant users. Hear Res 2018; 363:55-61. [PMID: 29548706 DOI: 10.1016/j.heares.2018.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 02/19/2018] [Accepted: 03/02/2018] [Indexed: 11/29/2022]
Abstract
Past studies have found that contralateral masking functions are sharper than ipsilateral masking functions for cochlear implant (CI) users. This could suggest that contralateral masking effects are only sensitive to the peak of the masker stimulation for this population. To determine if that is the case, this study investigated whether using broader stimulation patterns affects the broadness of the contralateral masking function. Contralateral masking functions were measured for six bilateral CI users using both a broad and narrow masker. Findings from this study revealed that the broad masker resulted in a broader contralateral masking function. This would suggest that stimulation outside of the peak of the masker affects contralateral masking functions for CI users.
Collapse
Affiliation(s)
- Daniel H Lee
- Department of Speech and Hearing Science, University of Illinois at Urbana-Champaign, 901 S. 6th St., Champaign, IL 61820, USA.
| | - Justin M Aronoff
- Department of Speech and Hearing Science, University of Illinois at Urbana-Champaign, 901 S. 6th St., Champaign, IL 61820, USA.
| |
Collapse
|