Wilson JM, Maradit-Kremers H, Abdel MP, Berry DJ, Mabry TM, Pagnano MW, Perry KI, Sierra RJ, Taunton MJ, Trousdale RT, Lewallen DG. Comparative Survival of Contemporary Cementless Acetabular Components Following Revision Total Hip Arthroplasty.
J Arthroplasty 2023;
38:S194-S200. [PMID:
37028772 PMCID:
PMC10330048 DOI:
10.1016/j.arth.2023.03.093]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 03/28/2023] [Accepted: 03/30/2023] [Indexed: 04/09/2023] Open
Abstract
BACKGROUND
The advent of highly porous ingrowth surfaces and highly crosslinked polyethylene has been expected to improve implant survivorship in revision total hip arthroplasty. Therefore, we sought to evaluate the survival of several contemporary acetabular designs following revision total hip arthroplasty.
METHODS
Acetabular revisions performed from 2000 to 2019 were identified from our institutional total joint registry. We studied 3,348 revision hips, implanted with 1 of 7 cementless acetabular designs. These were paired with highly crosslinked polyethylene or dual-mobility liners. A historical series of 258 Harris-Galante-1 components, paired with conventional polyethylene, was used as reference. Survivorship analyses were performed. For the 2,976 hips with minimum 2-year follow-up, the median follow-up was 8 years (range, 2 to 35 years).
RESULTS
Contemporary components with adequate follow-up had survivorship free of acetabular rerevision of ≥95% at 10-year follow-up. Relative to Harris-Galante-1 components, 10-year survivorship free of all-cause acetabular cup rerevision was significantly higher in Zimmer Trabecular Metarevision (hazard ratio (HR) 0.3, 95% confidence interval (CI) 0.2-0.45), Zimmer Trabecular MetaModular (HR 0.34, 95% CI 0.13-0.89), Zimmer Trilogy (HR 0.4, 95% CI 0.24-0.69), DePuy Pinnacle Porocoat (HR 0.24, 95% CI 0.11-0.51), and Stryker Tritanium revision (HR 0.46, 95% CI 0.24-0.91) shells. Among contemporary components, there were only 23 rerevisions for acetabular aseptic loosening and no rerevisions for polyethylene wear.
CONCLUSION
Contemporary acetabular ingrowth and bearing surfaces were associated with no rerevisions for wear and aseptic loosening was uncommon, particularly with highly porous designs. Therefore, it appears that contemporary revision acetabular components have dramatically improved upon historical results at available follow-up.
Collapse