1
|
Saenko V, Mitsutake N. Radiation-Related Thyroid Cancer. Endocr Rev 2024; 45:1-29. [PMID: 37450579 PMCID: PMC10765163 DOI: 10.1210/endrev/bnad022] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 04/18/2023] [Accepted: 07/07/2023] [Indexed: 07/18/2023]
Abstract
Radiation is an environmental factor that elevates the risk of developing thyroid cancer. Actual and possible scenarios of exposures to external and internal radiation are multiple and diverse. This article reviews radiation doses to the thyroid and corresponding cancer risks due to planned, existing, and emergency exposure situations, and medical, public, and occupational categories of exposures. Any exposure scenario may deliver a range of doses to the thyroid, and the risk for cancer is addressed along with modifying factors. The consequences of the Chornobyl and Fukushima nuclear power plant accidents are described, summarizing the information on thyroid cancer epidemiology, treatment, and prognosis, clinicopathological characteristics, and genetic alterations. The Chornobyl thyroid cancers have evolved in time: becoming less aggressive and driver shifting from fusions to point mutations. A comparison of thyroid cancers from the 2 areas reveals numerous differences that cumulatively suggest the low probability of the radiogenic nature of thyroid cancers in Fukushima. In view of continuing usage of different sources of radiation in various settings, the possible ways of reducing thyroid cancer risk from exposures are considered. For external exposures, reasonable measures are generally in line with the As Low As Reasonably Achievable principle, while for internal irradiation from radioactive iodine, thyroid blocking with stable iodine may be recommended in addition to other measures in case of anticipated exposures from a nuclear reactor accident. Finally, the perspectives of studies of radiation effects on the thyroid are discussed from the epidemiological, basic science, and clinical points of view.
Collapse
Affiliation(s)
- Vladimir Saenko
- Department of Radiation Molecular Epidemiology, Atomic Bomb Disease Institute, Nagasaki University, Nagasaki 852-8523, Japan
| | - Norisato Mitsutake
- Department of Radiation Molecular Epidemiology, Atomic Bomb Disease Institute, Nagasaki University, Nagasaki 852-8523, Japan
- Department of Radiation Medical Sciences, Atomic Bomb Disease Institute, Nagasaki University, Nagasaki 852-8523, Japan
| |
Collapse
|
2
|
Lorenzana DJ, Solomon J, French RJ, McCrum E, Jonkergouw F, Anakwenze OA, Lassiter T, Samei E, Klifto CS. Comparison of Simulated Low-Dose and Conventional-Dose CT for Preoperative Planning in Shoulder Arthroplasty. J Bone Joint Surg Am 2022; 104:1004-1014. [PMID: 35648067 DOI: 10.2106/jbjs.20.01916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Shoulder computed tomography (CT) is commonly utilized in preoperative planning for total shoulder arthroplasty. Conventional-dose shoulder CT may expose patients to more ionizing radiation than is necessary to provide high-quality images for this procedure. The purpose of this study was to evaluate the utility of simulated low-dose CT images for preoperative planning using manual measurements and common preoperative planning software. METHODS Eighteen shoulder CT scans obtained for preoperative arthroplasty planning were used to generate CT images as if they had been acquired at reduced radiation dose (RD) levels of 75%, 50%, and 25% using a simulation technique that mimics decreased x-ray tube current. This technique was validated by quantitative comparison of simulated low-dose scans of a cadaver with actual low-dose scans. Glenoid version, glenoid inclination, and humeral head subluxation were measured using 2 commercially available software platforms and were also measured manually by 3 physicians. These measurements were then analyzed for agreement across RD levels for each patient. Tolerances of 5° of glenoid version, 5° of glenoid inclination, and 10% humeral head subluxation were used as equivalent for preoperative planning purposes. RESULTS At all RD levels evaluated, the preoperative planning software successfully segmented the CT images. Semiautomated software measurement of 25% RD images was within tolerances in 99.1% of measurements; for 50% RD images, within tolerances in 96.3% of measurements; and for 75% RD images, within tolerances in 100% of measurements. Manual measurements of 25% RD images were within these tolerances in 95.1% of measurements; for 50% RD images, in 98.8% of measurements; and for 75% RD images, in 99.4% of measurements. CONCLUSIONS Simulated low-dose CT images were sufficient for reliable measurement of glenoid version, glenoid inclination, and humeral head subluxation by preoperative planning software as well as by physician-observers. These findings suggest the potential for substantial reduction in RD in preoperative shoulder CT scans without compromising surgical planning. CLINICAL RELEVANCE The adoption of low-dose techniques in preoperative shoulder CT may lower radiation exposure for patients undergoing shoulder arthroplasty, without compromising image quality.
Collapse
Affiliation(s)
- Daniel J Lorenzana
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Justin Solomon
- Department of Radiology, Duke University Medical Center, Durham, North Carolina
| | - Robert J French
- Department of Radiology, Duke University Medical Center, Durham, North Carolina
| | - Erin McCrum
- Department of Radiology, Duke University Medical Center, Durham, North Carolina
| | | | - Oke A Anakwenze
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Tally Lassiter
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Ehsan Samei
- Department of Radiology, Duke University Medical Center, Durham, North Carolina
| | - Christopher S Klifto
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| |
Collapse
|
3
|
Jeyasugiththan J, Kumarihami AMC, Satharasinghe D, Mahakumara P, Senanayaka G, Jayakody I. Evaluation of thyroid radiation dose during abdominal Computed Tomography procedures and dose reduction effectiveness of thyroid shielding. Radiography (Lond) 2022; 28:704-710. [PMID: 35461784 DOI: 10.1016/j.radi.2022.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 04/08/2022] [Accepted: 04/11/2022] [Indexed: 11/26/2022]
Abstract
INTRODUCTION During abdominal Computed Tomography (CT) studies, vicinity organs receive a dose from scatter radiation. The thyroid is considered an organ at greater risk due to high radiosensitivity. METHODS The primary objective of this study was to determine the entrances surface dose (ESD) to the thyroid during abdominal CT studies and to evaluate the efficiency of dose reduction by lead shielding. The calibrated thermoluminescence dosimeter (TLD) chips were used to measure the ESD during 180 contrast-enhanced (CE) and non-contrast-enhanced (NC) abdominal CT studies in the presence and absence of lead shielding. RESULTS Thyroid shielding reduces the ESD by 72.3% (0.55 mGy), 86.5% (2.95 mGy) and 64.0% (2.24 mGy) during NC, 3-phase and 4-phase abdominal CT scans. Also, the patient height was identified as a parameter that inversely influenced the thyroid dose, proving that the taller patients receive less dose to the thyroid. Regardless, the scan parameters such as time and display field of view (DFOV) positively impact the thyroid dose. CONCLUSION Lead shielding can prevent the external scatter reaching the thyroid region by 64%-87% during the non-vicinity scans such as abdomen CT. However, the actual dose saving lies between 0.2% and 0.4%, compared to the total effective dose of the whole CT procedure. IMPLICATIONS FOR PRACTICE The thyroid shield can effectively reduce external scatter radiation during abdominal CT procedures. However, the dose saving is insignificant compared to the total effective dose from the whole examination. Therefore, the use of thyroid shielding should be carefully evaluated during CT abdomen procedures.
Collapse
Affiliation(s)
- J Jeyasugiththan
- Department of Nuclear Science, University of Colombo, Colombo, 00300, Sri Lanka.
| | - A M C Kumarihami
- Department of Nuclear Science, University of Colombo, Colombo, 00300, Sri Lanka; Department of Radiology, University Hospital of General Sir John Kotelawala Defence University, Werahera, 10290, Sri Lanka
| | - D Satharasinghe
- Department of Nuclear Science, University of Colombo, Colombo, 00300, Sri Lanka
| | - P Mahakumara
- Radiation Protection and Technical Services Division, Sri Lanka Atomic Energy Board, Baseline Road, Orugodawatta, Wellampitiya, Sri Lanka
| | - G Senanayaka
- Department of Radiology, University Hospital of General Sir John Kotelawala Defence University, Werahera, 10290, Sri Lanka; Department of Clinical Sciences, Faculty of Medicine, Sir John Kotelawala Defence University, Ratmalana, 10390, Sri Lanka
| | - I Jayakody
- Department of Nuclear Science, University of Colombo, Colombo, 00300, Sri Lanka
| |
Collapse
|
4
|
Pérez Fuentes JA, Roldán Sánchez VS, Gordillo Ledesma AK, Mena AF, Brito S, Soteldo C. Mean glandular dose in the mammary gland and dose of radiation in the thyroid gland and lens in women with and without breast implants during different modalities of mammography. RADIOLOGIA 2022; 64 Suppl 1:11-19. [PMID: 35428461 DOI: 10.1016/j.rxeng.2020.10.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 10/22/2020] [Indexed: 11/24/2022]
Abstract
There have always been concerns about the secondary effects of diagnostic methods that use ionizing radiation. During mammography, the parameters to be concerned about are the mean glandular dose and the scatter dose. We evaluated the dose of radiation to the breast, thyroid gland, and lens in digital mammography in women with and without implants, in tomosynthesis in women with and without implants, and in contrast-enhanced mammography. MATERIALS AND METHODS The study included 212 women with and without disease who were attended at the Centro Clínico de Estereotaxia, CECLINES, in Caracas, Venezuela, between June 2017 and August 2017; the women were classified into five groups according to the mammographic modality used to evaluate them and whether or not they had implants. The statistical analysis included descriptive statistics for the study population. We used the Mann-Whitney U to compare the mean glandular dose and dose in the thyroid gland and lens between groups. RESULTS The mean glandular dose and the dose of radiation received in the thyroid and lens were within the acceptable range. In a few exceptions, the mean glandular dose per view was slightly higher than 3 mGy. The scatter dose to the thyroid gland and the lens during mammography has a very small contribution to the annual dose equivalent. CONCLUSION The mean glandular dose and the scatter dose to the thyroid gland and lens delivered during tomosynthesis and 2D mammography in women with implants were higher than those delivered during other mammographic techniques in women without implants.
Collapse
Affiliation(s)
| | - V S Roldán Sánchez
- Instituto Venezolano de Investigaciones Científicas, Edo, Miranda, Venezuela
| | | | - A F Mena
- Centro Clínico de Estereotaxia - CECLINES, Caracas, Venezuela
| | - S Brito
- Centro Clínico de Estereotaxia - CECLINES, Caracas, Venezuela
| | - C Soteldo
- Instituto Venezolano de Investigaciones Científicas, Edo, Miranda, Venezuela
| |
Collapse
|
5
|
Morris MA, Saboury B, Ahlman M, Malayeri AA, Jones EC, Chen CC, Millo C. Parathyroid Imaging: Past, Present, and Future. Front Endocrinol (Lausanne) 2022; 12:760419. [PMID: 35283807 PMCID: PMC8914059 DOI: 10.3389/fendo.2021.760419] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 10/21/2021] [Indexed: 12/30/2022] Open
Abstract
The goal of parathyroid imaging is to identify all sources of excess parathyroid hormone secretion pre-operatively. A variety of imaging approaches have been evaluated and utilized over the years for this purpose. Ultrasound relies solely on structural features and is without radiation, however is limited to superficial evaluation. 4DCT and 4DMRI provide enhancement characteristics in addition to structural features and dynamic enhancement has been investigated as a way to better distinguish parathyroid from adjacent structures. It is important to recognize that 4DCT provides valuable information however results in much higher radiation dose to the thyroid gland than the other available examinations, and therefore the optimal number of phases is an area of controversy. Single-photon scintigraphy with 99mTc-Sestamibi, or dual tracer 99mTc-pertechnetate and 99mTc-sestamibi with or without SPECT or SPECT/CT is part of the standard of care in many centers with availability and expertise in nuclear medicine. This molecular imaging approach detects cellular physiology such as mitochondria content found in parathyroid adenomas. Combining structural imaging such as CT or MRI with molecular imaging in a hybrid approach allows the ability to obtain robust structural and functional information in one examination. Hybrid PET/CT is widely available and provides improved imaging and quantification over SPECT or SPECT/CT. Emerging PET imaging techniques, such as 18F-Fluorocholine, have the exciting potential to reinvent parathyroid imaging. PET/MRI may be particularly well suited to parathyroid imaging, where available, because of the ability to perform dynamic contrast-enhanced imaging and co-registered 18F-Fluorocholine PET imaging simultaneously with low radiation dose to the thyroid. A targeted agent specific for a parathyroid tissue biomarker remains to be identified.
Collapse
Affiliation(s)
| | | | | | | | | | - Clara C. Chen
- National Institutes of Health (NIH) Clinical Center, Department of Radiology and Imaging Sciences, Bethesda, MD, United States
| | - Corina Millo
- National Institutes of Health (NIH) Clinical Center, Department of Radiology and Imaging Sciences, Bethesda, MD, United States
| |
Collapse
|
6
|
Zidane M, Truong T, Lesueur F, Xhaard C, Cordina-Duverger E, Boland A, Blanché H, Ory C, Chevillard S, Deleuze JF, Souchard V, Ren Y, Zemmache MZ, Canale S, Borson-Chazot F, Schvartz C, Mariné Barjoan E, Guizard AV, Laurent-Puig P, Mulot C, Guibon J, Karimi M, Schlumberger M, Adjadj E, Rubino C, Guenel P, Cazier JB, de Vathaire F. Role of DNA Repair Variants and Diagnostic Radiology Exams in Differentiated Thyroid Cancer Risk: A Pooled Analysis of Two Case-Control Studies. Cancer Epidemiol Biomarkers Prev 2021; 30:1208-1217. [PMID: 33827984 DOI: 10.1158/1055-9965.epi-20-1142] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 11/12/2020] [Accepted: 03/29/2021] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Given the increased use and diversity of diagnostic procedures, it is important to understand genetic susceptibility to radiation-induced thyroid cancer. METHODS On the basis of self-declared diagnostic radiology examination records in addition to existing literature, we estimated the radiation dose delivered to the thyroid gland from diagnostic procedures during childhood and adulthood in two case-control studies conducted in France. A total of 1,071 differentiated thyroid cancer (DTC) cases and 1,188 controls from the combined studies were genotyped using a custom-made Illumina OncoArray DNA chip. We focused our analysis on variants in genes involved in DNA damage response and repair pathways, representing a total of 5,817 SNPs in 571 genes. We estimated the OR per milli-Gray (OR/mGy) of the radiation dose delivered to the thyroid gland using conditional logistic regression. We then used an unconditional logistic regression model to assess the association between DNA repair gene variants and DTC risk. We performed a meta-analysis of the two studies. RESULTS The OR/mGy was 1.02 (95% confidence interval, 1.00-1.03). We found significant associations between DTC and rs7164173 in CHD2 (P = 5.79 × 10-5), rs6067822 in NFATc2 (P = 9.26 × 10-5), rs1059394 and rs699517 both in ENOSF1/THYS, rs12702628 in RPA3, and an interaction between rs7068306 in MGMT and thyroid radiation doses (P = 3.40 × 10-4). CONCLUSIONS Our results suggest a role for variants in CDH2, NFATc2, ENOSF1/THYS, RPA3, and MGMT in DTC risk. IMPACT CDH2, NFATc2, ENOSF1/THYS, and RPA3 have not previously been shown to be associated with DTC risk.
Collapse
Affiliation(s)
- Monia Zidane
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Thérèse Truong
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Fabienne Lesueur
- Inserm, U900, Institut Curie, Université PSL, Mines ParisTech, Paris, France
| | - Constance Xhaard
- INSERM Centre d'Investigation Clinique CIC-P 1433, CHRU Nancy, France
- INSERM U1116, FCRIN INI-CRCT, Lorraine Université, Nancy, France
| | - Emilie Cordina-Duverger
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Anne Boland
- Université Paris-Saclay, CEA, Centre National de Recherche en Génomique Humaine, Evry, France
| | - Hélène Blanché
- Fondation Jean Dausset-CEPH (Centre Etude du Polymorphisme Humain), Paris, France
- Laboratory of Excellence GENMED (Medical Genomics)
| | - Catherine Ory
- CEA, Direction de la Recherche Fondamentale, Institut de Biologie François Jacob, iRCM, SREIT, Laboratoire de Cancérologie Expérimentale (LCE), Université Paris-Saclay, Fontenay-aux-Roses, France
| | - Sylvie Chevillard
- CEA, Direction de la Recherche Fondamentale, Institut de Biologie François Jacob, iRCM, SREIT, Laboratoire de Cancérologie Expérimentale (LCE), Université Paris-Saclay, Fontenay-aux-Roses, France
| | - Jean-François Deleuze
- Université Paris-Saclay, CEA, Centre National de Recherche en Génomique Humaine, Evry, France
- Fondation Jean Dausset-CEPH (Centre Etude du Polymorphisme Humain), Paris, France
- Laboratory of Excellence GENMED (Medical Genomics)
| | - Vincent Souchard
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Yan Ren
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Mohammed Zakarya Zemmache
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | | | - Françoise Borson-Chazot
- Rhône-Alpes Thyroid Cancer Registry, Cancer Research Center of Lyon (UMR INSERM 1052, CNRS 5286), RTH Laennec Faculty of Medicine, University of Lyon, Lyon
| | - Claire Schvartz
- Thyroid Cancer Registry of Champagne-Ardennes, Institut Jean Godinot, Reims, Cancer Registry of Isère, Meylan
| | | | - Anne-Valérie Guizard
- Registre Général des Tumeurs du Calvados, Centre François Baclesse, Caen, France
- U1086 INSERM-UCN "ANTICIPE," Caen, France
| | - Pierre Laurent-Puig
- Centre de Recherche des Cordeliers, INSERM, Sorbonne Université, USPC, Université Paris Descartes, Université Paris Diderot, EPIGENETEC, Paris, France
| | - Claire Mulot
- Centre de Recherche des Cordeliers, INSERM, Sorbonne Université, USPC, Université Paris Descartes, Université Paris Diderot, EPIGENETEC, Paris, France
| | - Julie Guibon
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
- Inserm, U900, Institut Curie, Université PSL, Mines ParisTech, Paris, France
| | - Mojgan Karimi
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Martin Schlumberger
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Elizabeth Adjadj
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
| | - Carole Rubino
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Pascal Guenel
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| | - Jean-Baptiste Cazier
- Institute of Cancer and Genomic Sciences, Centre for Computational Biology, University of Birmingham, Birmingham, UK
| | - Florent de Vathaire
- INSERM, Centre for Research in Epidemiology and Population Health (CESP), 94800 Villejuif, France.
- Université Paris-Sud Orsay, Villejuif, France
- Gustave Roussy, Villejuif, France
| |
Collapse
|
7
|
Pérez Fuentes JA, Roldán Sánchez VS, Gordillo Ledesma AK, Mena AF, Brito S, Soteldo C. Mean glandular dose in the mammary gland and dose of radiation in the thyroid gland and lens in women with and without breast implants during different modalities of mammography. RADIOLOGIA 2021; 64:S0033-8338(21)00017-5. [PMID: 33549317 DOI: 10.1016/j.rx.2020.10.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 10/03/2020] [Accepted: 10/22/2020] [Indexed: 11/16/2022]
Abstract
There have always been concerns about the secondary effects of diagnostic methods that use ionizing radiation. During mammography, the parameters to be concerned about are the mean glandular dose and the scatter dose. We evaluated the dose of radiation to the breast, thyroid gland, and lens in digital mammography in women with and without implants, in tomosynthesis in women with and without implants, and in contrast-enhanced mammography. MATERIALS AND METHODS The study included 212 women with and without disease who were attended at the Centro Clínico de Estereotaxia, CECLINES, in Caracas, Venezuela, between June 2017 and August 2017; the women were classified into five groups according to the mammographic modality used to evaluate them and whether or not they had implants. The statistical analysis included descriptive statistics for the study population. We used the Mann-Whitney U to compare the mean glandular dose and dose in the thyroid gland and lens between groups. RESULTS The mean glandular dose and the dose of radiation received in the thyroid and lens were within the acceptable range. In a few exceptions, the mean glandular dose per view was slightly higher than 3mGy. The scatter dose to the thyroid gland and the lens during mammography has a very small contribution to the annual dose equivalent. CONCLUSION The mean glandular dose and the scatter dose to the thyroid gland and lens delivered during tomosynthesis and 2D mammography in women with implants were higher than those delivered during other mammographic techniques in women without implants.
Collapse
Affiliation(s)
| | - V S Roldán Sánchez
- Instituto Venezolano de Investigaciones Científicas, Edo, Miranda, Venezuela
| | | | - A F Mena
- Centro Clínico de Estereotaxia - CECLINES, Caracas, Venezuela
| | - S Brito
- Centro Clínico de Estereotaxia - CECLINES, Caracas, Venezuela
| | - C Soteldo
- Instituto Venezolano de Investigaciones Científicas, Edo, Miranda, Venezuela
| |
Collapse
|
8
|
Luan FJ, Zhang J, Mak KC, Liu ZH, Wang HQ. Low Radiation X-rays: Benefiting People Globally by Reducing Cancer Risks. Int J Med Sci 2021; 18:73-80. [PMID: 33390775 PMCID: PMC7738971 DOI: 10.7150/ijms.48050] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 10/13/2020] [Indexed: 12/29/2022] Open
Abstract
Modern medical imaging facilitates the diagnosis and treatment of human diseases. However, few people are aware of the cons of radiation exposure from medical imaging. Emerging evidence reveals that cumulative doses of radiation exposure will increase the morbidity and mortality of pertaining cancer. As a special young population, patients with adolescent idiopathic scoliosis (AIS) suffer more radiation harms from repeated diagnostic imaging, most of which can be avoided in clinical practice. Accumulating evidence highlights reduced cancer risks of radiation exposure for AIS patients with low/zero radiation imaging modalities proposed, amongst which easy conversion from anterior-posterior (AP) to posterior-anterior (PA) projection for whole-spine radiographs should be stressed. It can greatly reduce radiation doses without compromising the quality of diagnostic imaging. Tight collimation combined with PA projection can further reduce radiation harms, and need to be spread to benefit people globally.
Collapse
Affiliation(s)
- Fu-Jun Luan
- Department of Orthopaedics, Yongchuan Hospital of Chongqing Medical University, Chongqing City, P. R. China, 402160
| | - Jun Zhang
- Department of Orthopaedics, Baoji Municipal Central Hospital, Baoji, Shaanxi, China, 721008
| | - Kin-Cheung Mak
- Spine Central, Specialist Central, The Hong Kong Adventist Hospital, Hong Kong SAR, China
| | - Zhi-Heng Liu
- Department of Orthopaedics, Chinese PLA No.986 Hospital, Fourth Military Medical University, Xi'an, Shaanxi Province, P. R. China, 710054
| | - Hai-Qiang Wang
- Institute of Integrative Medicine, Shaanxi University of Chinese Medicine, Xi'an, Shaanxi Province, P. R. China, 712046
| |
Collapse
|
9
|
Cancer and mortality risks of patients with scoliosis from radiation exposure: a systematic review and meta-analysis. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2020; 29:3123-3134. [PMID: 32852591 DOI: 10.1007/s00586-020-06573-7] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 07/12/2020] [Accepted: 08/16/2020] [Indexed: 01/08/2023]
|
10
|
Fontana RC, Pasqual E, Miller DL, Simon SL, Cardis E, Thierry-Chef I. Trends in Estimated Thyroid, Salivary Gland, Brain, and Eye Lens Doses From Intraoral Dental Radiography Over Seven Decades (1940 TO 2009). HEALTH PHYSICS 2020; 118:136-148. [PMID: 31634260 PMCID: PMC6940029 DOI: 10.1097/hp.0000000000001138] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 05/29/2019] [Indexed: 06/10/2023]
Abstract
The purpose of this study is to support retrospective dose estimation for epidemiological studies by providing estimates of historical absorbed organ doses to the brain, lens of the eye, salivary glands, and thyroid from intraoral dental radiographic examinations performed from 1940 to 2009. We simulated organ doses to an adult over 10 y time periods from 1940 to 2009, based on commonly used sets of x-ray machine settings collected from the literature. Simulations to estimate organ dose were performed using personal computer x-ray Monte Carlo software. Overall, organ doses were less than 1 mGy for a single intraoral radiograph for all decades. From 1940 to 2009, doses to the brain, eye lens, salivary glands, and thyroid decreased by 86, 96, 95, and 89%, respectively. Of these four organs, the salivary glands received the highest doses, with values decreasing from about 0.23 mGy in the 1940s to 0.025 mGy in the 2000s for a single intraoral radiograph. Based on simulations using collected historical data on x-ray technical parameters, improvements in technology and optimization of the technical settings used to perform intraoral dental radiography have resulted in a decrease in absorbed dose to the brain, eye lens, salivary glands, and thyroid over the period from 1940 to 2009.
Collapse
Affiliation(s)
| | | | - D L Miller
- Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD
| | - S L Simon
- Division of Cancer Epidemiology and Genetics, National Institutes of Health, National Cancer Institute, Bethesda, MD
| | | | | |
Collapse
|
11
|
Memon A, Rogers I, Paudyal P, Sundin J. Dental X-Rays and the Risk of Thyroid Cancer and Meningioma: A Systematic Review and Meta-Analysis of Current Epidemiological Evidence. Thyroid 2019; 29:1572-1593. [PMID: 31502516 DOI: 10.1089/thy.2019.0105] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Background: Exposure to moderate-to-high doses of ionizing radiation is the only established environmental risk factor for thyroid cancer and brain and central nervous system tumors. Considering the high lifetime prevalence and frequency of exposure to dental X-rays, the most common source of diagnostic radiation exposure in the general population, even a small associated increase in cancer risk would be of considerable public health importance. With the objective to inform clinical practice and guidelines, we synthesized the current epidemiological evidence on the association between dental X-rays and the risk of thyroid cancer, meningioma, and other cancers of the head and neck region. Methods: The Medline, Embase, and Web of Science databases were searched to identify eligible studies. Summary odds ratio/relative risk estimates and confidence intervals were extracted, and pooled risk ratios (RRs) for each cancer were calculated using random effects meta-analysis. Results: The literature search identified 5537 publications; of these, 26 studies including 10,868 cancer patients were included in the synthesis. The random effects meta-analyses, based on seven studies of thyroid cancer (six case/control, one cohort) and eight studies of meningioma (all case/control), showed that multiple (or repeated) exposures to dental X-rays were significantly associated with an increased risk of thyroid cancer (pooled RR = 1.87 [95% confidence interval, CI 1.11-3.15]) and meningioma (pooled RR = 1.53 [CI 1.26-1.85]). There was no association with glioma, and there were too few studies of other cancers of the head and neck region to conduct a meaningful meta-analysis. Conclusions: Based on a meta-analysis of retrospective case/control studies, these findings provide some support to the hypothesis that multiple (or repeated) exposures to dental X-rays may be associated with an increased risk of thyroid cancer and meningioma. These studies did not include individual organ doses and ages at exposure, and are subject to recall bias and other limitations. Furthermore, the thyroid exposure has decreased dramatically over time from the use of thyroid shields and improved technology/equipment. Prospective studies, based on dental X-ray records and patient follow-up, are needed to test the hypothesis further and clarify the possible cancer risk associated with dental radiography, as although the risk at the individual level, particularly with improved technology/equipment, is likely to be very low, the proportion of the population exposed is high. Considering that about one-third of the general population in developed countries is routinely exposed to one or more dental X-rays per year, these findings manifest the need to reduce diagnostic radiation exposure as much as possible.
Collapse
Affiliation(s)
- Anjum Memon
- Department of Primary Care and Public Health, Brighton and Sussex Medical School, Brighton, United Kingdom
| | - Imogen Rogers
- Department of Primary Care and Public Health, Brighton and Sussex Medical School, Brighton, United Kingdom
| | - Priyamvada Paudyal
- Department of Primary Care and Public Health, Brighton and Sussex Medical School, Brighton, United Kingdom
| | - Josefin Sundin
- Department of Primary Care and Public Health, Brighton and Sussex Medical School, Brighton, United Kingdom
| |
Collapse
|
12
|
Little MP, Lim H, Friesen MC, Preston DL, Doody MM, Sigurdson AJ, Neta G, Alexander BH, Chang LA, Cahoon EK, Simon SL, Linet MS, Kitahara CM. Assessment of thyroid cancer risk associated with radiation dose from personal diagnostic examinations in a cohort study of US radiologic technologists, followed 1983-2014. BMJ Open 2018; 8:e021536. [PMID: 29764888 PMCID: PMC5961563 DOI: 10.1136/bmjopen-2018-021536] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVE To assess whether personal medical diagnostic procedures over life, but particularly those associated with exposure in adulthood, were associated with increased thyroid cancer risk. DESIGN Participants from the US Radiologic Technologists Study, a large, prospective cohort, were followed from the date of first mailed questionnaire survey completed during 1983-1989 to the earliest date of self-reported diagnosis of thyroid cancer or of any other cancer than non-melanoma skin cancer (NMSC) in any of three subsequent questionnaires up to the last in 2012-2014. SETTING US nationwide, occupational cohort. PARTICIPANTS US radiologic technologists with exclusion of: those who reported a previous cancer apart from NMSC on the first questionnaire; those who reported a cancer with an unknown date of diagnosis on any of the questionnaires; and those who did not respond to both the first questionnaire and at least one subsequent questionnaire. PRIMARY OUTCOME MEASURE We used Cox proportional hazards models with age as timescale to compute HRs and 95% CI for thyroid cancer in relation to cumulative 5-year lagged diagnostic thyroid dose. RESULTS There were 414 self-reported thyroid cancers (n=275 papillary) in a cohort of 76 415 persons. Cumulative thyroid dose was non-significantly positively associated with total (excess relative risk/Gy=2.29 (95% CI -0.91 to 7.01, p=0.19)) and papillary thyroid cancer (excess relative risk/Gy=4.15 (95% CI -0.39, 11.27, p=0.08)) risk. These associations were not modified by age at, or time since, exposure and were independent of occupational exposure. CONCLUSION Our study provides weak evidence that thyroid dose from diagnostic radiation procedures over the whole of life, in particular associated with exposure in adulthood, influences adult thyroid cancer risk.
Collapse
Affiliation(s)
- Mark P Little
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Hyeyeun Lim
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Melissa C Friesen
- Occupational and Environmental Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | | | - Michele M Doody
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Alice J Sigurdson
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Gila Neta
- Division of Cancer Control and Population Sciences, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Bruce H Alexander
- Division of Environmental Health Sciences, School of Public Health, University of Minnesota, Minneapolis, Minnesota, USA
| | - Lienard A Chang
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
- Department of Radiation Safety and Imaging Physics, Houston Methodist Hospital, Houston, Texas, USA
| | - Elizabeth K Cahoon
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Steven L Simon
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Martha S Linet
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| | - Cari M Kitahara
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, Maryland, USA
| |
Collapse
|
13
|
Borrego D, Lowe EM, Kitahara CM, Lee C. Assessment of PCXMC for patients with different body size in chest and abdominal x ray examinations: a Monte Carlo simulation study. Phys Med Biol 2018; 63:065015. [PMID: 29465419 DOI: 10.1088/1361-6560/aab13e] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
A PC Program for x ray Monte Carlo (PCXMC) has been used to calculate organ doses in patient dosimetry and for the exposure assessment in epidemiological studies of radiogenic health related risks. This study compared the dosimetry from using the built-in stylized phantoms in the PCXMC to that of a newer hybrid phantom library with improved anatomical realism. We simulated chest and abdominal x ray projections for 146 unique body size computational phantoms, 77 males and 69 females, with different combinations of height (125-180 cm) and weight (20-140 kg) using the built-in stylized phantoms in the PCXMC version 2.0.1.4 and the hybrid phantom library using the Monte Carlo N-particle eXtended transport code 2.7 (MCNPX). Unfortunately, it was not possible to incorporate the hybrid phantom library into the PCXMC. We compared 14 organ doses, including dose to the active bone marrow, to evaluate differences between the built-in stylized phantoms in the PCXMC and the hybrid phantoms (Cristy and Eckerman 1987 Technical Report ORNL/TM-8381/V1, Oak Ridge National Laboratory, Eckerman and Ryman 1993 Technical Report 12 Oak Ridge, TN, Geyer et al 2014 Phys. Med. Biol. 59 5225-42). On average, organ doses calculated using the built-in stylized phantoms in the PCXMC were greater when compared to the hybrid phantoms. This is most prominent in AP abdominal exams by an average factor of 2.4-, 2.8-, and 2.8-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. For chest exams, organ doses are greater by an average factor of 1.1-, 1.4-, and 1.2-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. The PCXMX, due to its ease of use, is often selected to support dosimetry in epidemiological studies; however, it uses simplified models of the human anatomy that fail to account for variations in body morphometry for increasing weight. For epidemiological studies that use PCXMC dosimetry, associations between radiation-related disease risks and organ doses may be underestimated, and to a greater degree in pediatric, especially obese pediatric, compared to adult patients.
Collapse
Affiliation(s)
- David Borrego
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, 9609 Medical Center Drive, Bethesda, MD 20892-9778, United States of America
| | | | | | | |
Collapse
|