1
|
Chao C, Skidmore K, Tomiyama ES, Wolffsohn JS, Richdale K. Soft toric contact lens wear improves digital performance and vision-A randomised clinical trial. Ophthalmic Physiol Opt 2023; 43:25-34. [PMID: 36169043 DOI: 10.1111/opo.13053] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 08/21/2022] [Accepted: 08/22/2022] [Indexed: 12/27/2022]
Abstract
PURPOSE To compare objective and subjective digital near visual performance and comfort in low to moderate astigmatic participants fitted with toric versus spherical equivalent silicone hydrogel daily disposable contact lenses. METHODS This was a double-masked, randomised, crossover study. Participants aged 18 to 39 years with astigmatism of -0.75 to -1.50 D were recruited and fitted with toric and spherical contact lenses, in random order. Outcomes were measured at baseline and after 1 week of wear with each contact lens type after the follow-up visits. High- and low-contrast near logMAR visual acuity, automated visual acuity, zoom (%), contrast (%), reading distance (cm), critical print size (logMAR) and reading speed were assessed. Participants also completed the validated Near Activity Visual Questionnaire (NAVQ) and Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8) for each correction type. RESULTS Twenty-three participants completed the study (74% female, average age 24.4 ± 4.2 years). When participants wore toric contact lenses, near high- and low-contrast visual acuity and automated visual acuity improved by 3-4 letters (all p < 0.03) and participants were able to read faster on an iPad (p = 0.02). Participants were also able to read with 8% less contrast on the iPad with toric lenses (p = 0.01). Participants reported better subjective vision on the overall NAVQ (p = 0.001) and better comfort on the CLDEQ-8 (p = 0.02) with toric lenses. Fewer participants reported difficulty with maintaining focus at near, reading small print, reading labels/instructions, reading the computer display/keyboard and reading post/mail with toric correction. CONCLUSIONS Toric contact lenses improve comfort, subjective and objective visual performance with digital devices and other near tasks compared with the spherical equivalent correction in participants with low to moderate astigmatism.
Collapse
Affiliation(s)
- Cecilia Chao
- College of Optometry, University of Houston, Houston, Texas, USA
| | - Kelsea Skidmore
- College of Optometry, University of Houston, Houston, Texas, USA
| | - Erin S Tomiyama
- College of Optometry, University of Houston, Houston, Texas, USA
| | | | - Kathryn Richdale
- College of Optometry, University of Houston, Houston, Texas, USA
| |
Collapse
|
2
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
3
|
Mirzapour P, McCanna DJ, Jones L. In vitro analysis of the interaction of tear film inflammatory markers with contemporary contact lens materials. Cont Lens Anterior Eye 2021; 44:101430. [PMID: 33771440 DOI: 10.1016/j.clae.2021.02.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 02/01/2021] [Accepted: 02/12/2021] [Indexed: 11/17/2022]
Abstract
PURPOSE Several clinical studies have suggested that reusable silicone hydrogel contact lens materials exhibit a two-times increased rate of corneal infiltrative events compared to reusable hydrogels. One potential factor contributing to this complication relates to the differential uptake of tear film-based pro-inflammatory cytokines. The purpose of this study was to use an in vitro assay to investigate whether four pro-inflammatory cytokines differed in their uptake onto six contemporary contact lens materials. METHODS Conventional hydrogel (etafilcon A, omafilcon A) and silicone hydrogel (balafilcon A, comfilcon A, senofilcon A, somofilcon A) contact lens materials were soaked in solutions containing pro-inflammatory cytokines IL-1β, IL-6, IL-8 and TNF-α. Samples of the soaking solutions were collected over various time points and analyzed using the Meso Scale Discovery system, which served as a measurement of cytokine uptake onto the contact lens materials. RESULTS Both conventional hydrogels (etafilcon A, omafilcon A) and two of the four silicone hydrogels tested (balafilcon A, comfilcon A), exhibited some uptake of IL-1β, IL-8 or TNF-α (p < 0.05). Senofilcon A and somofilcon A did not exhibit uptake of any of these cytokines (p > 0.05). There was no uptake of IL-6 onto any of the contact lens materials investigated (p > 0.05). CONCLUSION The contact lens materials tested did not exhibit any uptake of IL-6 and furthermore, did not exhibit more than 10 ± 3 % to 25 ± 12 % uptake of IL-1β, IL-8 or TNF-α. Numerous factors could contribute to the reported increase in corneal infiltrative events with reusable silicone hydrogel materials, however, based on these results, it appears that uptake of these four cytokines are unlikely to contribute to this finding.
Collapse
Affiliation(s)
- Parisa Mirzapour
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| | - David J McCanna
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada; Centre for Eye & Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| |
Collapse
|
4
|
López-de la Rosa A, González-García MJ, Calonge M, Enríquez-de-Salamanca A. Tear Inflammatory Molecules in Contact Lens Wearers: A Literature Review. Curr Med Chem 2020; 27:523-548. [DOI: 10.2174/0929867326666190409152921] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 03/14/2019] [Accepted: 03/22/2019] [Indexed: 01/20/2023]
Abstract
Background:
Numerous studies have analysed the effect of using different Contact
Lenses (CLs) or care solutions, and suffering discomfort or diseases associated with CL wear
on the inflammatory mediator release into the tears.
Objective:
To summarize the published data on tear inflammatory molecules related to CL use.
Methods:
A PubMed-NCBI search has been conducted and those publications which carried
out original investigations including the analysis of tear inflammatory mediators in CL wearers
were selected.
Results:
Forty-three articles, from 1990 to 2019, have been included. Wearing hydrogel CLs,
rigid gas permeable CLs, and special designs for irregular corneas in keratoconus patients (CLs
with keratoconic design, hybrid CLs, piggyback fit, and scleral CLs) have been reported to alter
the concentration of several molecules in tears. Moreover, there seems to be an effect of the
wearing time and schedule, CL materials and designs, and care solutions used. Regarding CL
discomfort, its relation with inflammatory mediators is not clear. However, some diseases associated
to CL wear, such as giant papillary conjunctivitis, CL induced acute red eye, CL induced
peripheral ulcer, and acanthamoeba keratitis have been related to the release of certain inflammatory
mediators, which may serve as potential biomarkers.
Conclusion:
There is evidence suggesting that different aspects of CL wear alter the inflammatory
mediator profile in tears, which may indicate an inflammatory state of the lacrimal functional
unit. However, more studies need to be carried out to better understand how this inflammatory
process works and its repercussion on the different aspects of CL wear.
Collapse
Affiliation(s)
| | | | - Margarita Calonge
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain
| | | |
Collapse
|
5
|
Chao C, Akileswaran L, Cooke Bailey JN, Willcox M, Van Gelder R, Lakkis C, Stapleton F, Richdale K. Potential Role of Ocular Microbiome, Host Genotype, Tear Cytokines, and Environmental Factors in Corneal Infiltrative Events in Contact Lens Wearers. Invest Ophthalmol Vis Sci 2019; 59:5752-5761. [PMID: 30516819 PMCID: PMC6281277 DOI: 10.1167/iovs.18-24845] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Purpose The purpose of this study was to explore differences in genotype, ocular surface microbiome, tear inflammatory markers, and environmental and behavioral exposures in soft contact lens (SCL) wearers with and without a history of corneal infiltrative events (CIEs). Methods Nine SCL wearers with a recent CIE and nine age-, sex-, and SCL material- and modality-matched controls were enrolled. The Contact Lens Risk Survey, slit-lamp examination data, basal tears, conjunctival microbial cultures, and peripheral blood samples were collected. Tear inflammatory mediator concentrations, genomic DNA from swabs, and whole exome sequencing of blood samples were quantified. Results There were no marked differences in SCL wear behaviors or exposures between case and control subjects. Predominant organisms detected among case and control subjects were Staphylococcus, Propionibacterium, Streptococcus, and Corynebacterium. Marginally higher levels of Neisseria were found in three of nine cases but zero of nine control samples (P = 0.056). A potentially deleterious missense single nucleotide polymorphism (SNP) variant in IL-6 Signal Transducer (IL6ST) was found in seven of eight cases and zero of nine controls (rs2228046; P = 0.03). The concentration of tear IL-6 was significantly higher in cases (4.5 [range, 2.1 to 6.2] pg/mL) versus controls (3.5 [range, 2.5 to 6.6] Pg/mL; = 0.02). Conclusions Tear IL-6 concentration was higher, and SNP variants were detected in subjects with a history of CIEs compared with healthy controls. The synthesis, signaling, and ocular surface cytokine concentration of IL-6 may be related to susceptibility to CIE. A larger study population is required to further explore relationships between genetic variations, the ocular surface microbiome, inflammatory mediators, and environmental exposures.
Collapse
Affiliation(s)
- Cecilia Chao
- Tufts Medical Center, Center for Translational Ocular Immunology, Boston, Massachusetts, United States.,University of New South Wales School of Optometry and Vision Science, Kensington, New South Wales, Australia
| | - Lakshmi Akileswaran
- Department of Ophthalmology, University of Washington Medical School, Seattle, Washington, United States
| | - Jessica N Cooke Bailey
- Department of Population and Quantitative Health Sciences, Case Western Reserve University, Institute for Computational Biology, Cleveland, Ohio, United States
| | - Mark Willcox
- University of New South Wales School of Optometry and Vision Science, Kensington, New South Wales, Australia
| | - Russell Van Gelder
- Department of Ophthalmology, University of Washington Medical School, Seattle, Washington, United States
| | - Carol Lakkis
- Johnson & Johnson Vision Care, Inc., Jacksonville, Florida, United States
| | - Fiona Stapleton
- University of New South Wales School of Optometry and Vision Science, Kensington, New South Wales, Australia
| | - Kathryn Richdale
- University of Houston College of Optometry, Houston, Texas, United States
| |
Collapse
|
6
|
Gad A, Vingrys AJ, Wong CY, Jackson DC, Downie LE. Tear film inflammatory cytokine upregulation in contact lens discomfort. Ocul Surf 2018; 17:89-97. [PMID: 30321605 DOI: 10.1016/j.jtos.2018.10.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 10/05/2018] [Accepted: 10/11/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE To investigate the ocular inflammatory response, using clinical and immunological techniques, in people experiencing contact lens (CL) discomfort. METHODS This study involved 38 adults who were full-time, silicone-hydrogel CL wearers. Participants were categorized into groups based upon a validated CL dry-eye questionnaire (CLDEQ-8) (n = 17 'asymptomatic', CLDEQ-8 score <9; n = 21 'symptomatic', CLDEQ-8 score ≥13). Examinations were performed at two visits (one with, and one without, CL wear), separated by one-week. Testing included: tear osmolarity, ocular redness, tear stability, ocular surface staining, meibography, tear production and tear collection. Tear osmolarity was taken from the inferior-lateral and superior-lateral menisci. The 'Inferior-Superior Osmotic Difference', I-SOD, was the absolute osmolarity difference between these menisci. Concentrations of seven cytokines (IL-2, IL-4, IL-6, IL-10, IL-17A, IFN-gamma, TNF-alpha) were assayed from basal tears using multiplex cytometric bead array. RESULTS At baseline, there was no significant difference in key clinical signs between asymptomatic and symptomatic CL wearers (p > 0.05). The I-SOD was greater in symptomatic than asymptomatic CL wearers (23.1 ± 2.6 versus 11.3 ± 1.4 mOsmol/L, p = 0.001). People experiencing CL discomfort had higher tear IL-17A (122.6 ± 23.7 versus 44.0 ± 10.0 pg/mL, p = 0.02) and reduced tear stability (6.3 ± 1.1 versus 10.4 ± 1.6 s, p = 0.03) after several hours of CL wear. Tear IL-17A levels correlated with both the I-SOD (r = 0.43, p = 0.01) and CLDEQ-8 score (r = 0.40, p = 0.01). CONCLUSIONS CL discomfort occurs in individuals having no clinical dry eye signs, and is associated with higher tear levels of the pro-inflammatory cytokine IL-17A. These findings support an association between the discomfort response and low-grade, ocular surface inflammation.
Collapse
Affiliation(s)
- Anne Gad
- Department of Optometry and Vision Sciences, Australia
| | | | - Chinn Yi Wong
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, 3010, Australia
| | - David Charles Jackson
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, 3010, Australia
| | | |
Collapse
|
7
|
Proteomics Unravels the Regulatory Mechanisms in Human Tears Following Acute Renouncement of Contact Lens Use: A Comparison between Hard and Soft Lenses. Sci Rep 2018; 8:11526. [PMID: 30069058 PMCID: PMC6070515 DOI: 10.1038/s41598-018-30032-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2018] [Accepted: 07/23/2018] [Indexed: 11/09/2022] Open
Abstract
Contact lenses (CLs) provide a superior alternative to spectacles. Although beneficial, the global burden of ocular dysfunctions attributed to regular use of CLs remains a topic of much challenge in ophthalmic research owing to debilitating clinical repercussions on the ocular surface, which are often manifested as breach in tear film integrity. This study elucidated the intricate tear proteome changes attributed to the use of different CLs (hard and soft) and unravelled, for the first time, the restorative mechanisms of several protein clusters following acute renouncement of CL use employing the label-free mass spectrometry-based quantitative proteomics approach. The expression patterns of certain proteins clusters were specific to the use of a particular lens type and a large majority of these actively regulates cell death and survival and, modulates cellular movement on the ocular surface. Noteworthy, CL use also evoked a significant upregulation of glycolytic enzymes associated with hypoxia and corresponding cognate metabolic pathways, particularly glucose metabolism and FXR/RXR pathways. Importantly, the assessment of CL renouncement unravelled the restorative properties of several clusters of proteins involved mainly in organismal injury and abnormalities and, cellular function and maintenance. These proteins play key roles in restoring tear homeostasis and wound-healing mechanisms post-CL use-elicited injury.
Collapse
|
8
|
Preinflammatory Signs in Established Reusable and Disposable Contact Lens Wearers. Optom Vis Sci 2017; 94:1003-1008. [DOI: 10.1097/opx.0000000000001129] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
9
|
Chao C, Richdale K, Jalbert I, Doung K, Gokhale M. Non-invasive objective and contemporary methods for measuring ocular surface inflammation in soft contact lens wearers - A review. Cont Lens Anterior Eye 2017; 40:273-282. [PMID: 28602547 DOI: 10.1016/j.clae.2017.05.008] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 05/25/2017] [Accepted: 05/29/2017] [Indexed: 10/19/2022]
Abstract
Contact lens wear is one of the primary risk factors for the development of ocular surface inflammatory events. The purpose of this review is to examine and summarize existing knowledge on the mechanisms of contact lens related ocular surface inflammation and the evidence for the effectiveness of current objective methods to measure ocular surface inflammation. Contact lens wear is postulated to trigger an inflammatory response on the ocular surface due to mechanical, chemical, hypoxic stress, or by the introduction of microbes and their toxins. Apart from the traditional signs of inflammation, such as swelling, oedema, redness and heat, on the ocular surface, other methods to measure ocular surface inflammation in sub-clinical levels include tear inflammatory mediator concentrations, conjunctival cell morphology, and corneal epithelial dendritic cell density and morphology. Tear inflammatory mediator concentrations are up- or down-regulated during contact lens wear, with or without the presence of associated inflammatory events. There is higher conjunctival cell metaplasia observed with contact lens wear, but changes in goblet cell density are inconclusive. Dendritic cell density is seen to increase soon after initiating soft contact lens wear. The long term effects of contact lens wear on dendritic cell migration in the cornea and conjunctiva, including the lid wiper area, require further investigation. Currently patient factors, such as age, smoking, systemic diseases and genetic profile are being studied. A better understanding of these mechanisms may facilitate the development of new management options and strategies to minimize ocular surface inflammation related to contact lens wear.
Collapse
Affiliation(s)
- Cecilia Chao
- College of Optometry, State University of New York, New York, USA; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Kathryn Richdale
- College of Optometry, State University of New York, New York, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Kim Doung
- College of Optometry, State University of New York, New York, USA
| | - Moneisha Gokhale
- Deakin Optometry, Deakin University, 75 Pigdons Road, Waurn Ponds, Victoria, 3216, Australia.
| |
Collapse
|