1
|
Ilechie A, Addo NA, Aidoo E, Armah A, Faheem F, Achimah BA. Physical properties of soft contact lens multipurpose solutions commercially available in Ghana. Heliyon 2024; 10:e32491. [PMID: 38952357 PMCID: PMC11215257 DOI: 10.1016/j.heliyon.2024.e32491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/31/2024] [Accepted: 06/05/2024] [Indexed: 07/03/2024] Open
Abstract
Purpose To investigate the physical properties of commercially available multipurpose soft contact lens solutions in Ghana. Methods pH (Kelilong ICL-099 pH meter, China), osmolality (OSMOMAT 3000, GONOTEC, Germany), surface tension (Sigma 700 Tensiometer, Sweden), and viscosity (CFOC-200 Viscometer, Cannon Company, USA) of various soft contact lens multipurpose solutions (MPS) were measured in triplicates at room temperature. Viscosity measurements were also taken at 34 °C ocular surface temperature. The solutions examined were Opti-Free Replenish (OFR), Trufresh (TF), Avizor (AV), Freshlook (FL), and Refresh (RF). Results Several solutions were largely hypo-osmotic in the range of 108-231 mOsm/kg, the exception being Avizor, which had osmolality values that were closer to human tears (301 ± 0.58 mOsm/kg). The range of pH values of the solutions (6.33-8.24, mean (SD) = 7.53 ± 0.18) fell within the reported tolerable range for the ocular surface (6.20-9.00). Surface tension values ranged from 35.86 to 42.27 mNm with a mean of 38.49 ± 2.32 mNm. The average viscosity of most solutions at room temperature (25 °C) was 1.44 ± 0.49 cP with a range of 1.04-2.15 cP. Significantly lower values ranging from 0.79 to 1.58 cP were obtained at ocular surface temperature (34 °C), p = 0.0001). Conclusions The physical properties of many of the solutions used as MPS in Ghana are markedly variable. Nevertheless, pH, surface tension, and viscosity fall within the acceptable limits of ocular physiological tolerance; except for osmolality, which majority were outside the reported tolerable range for the ocular surface. This information may partly explain the reason some patients exhibit strong preferences for certain care systems and should aid clinical decision-making when prescribing eye care systems to patients.
Collapse
Affiliation(s)
- Alex Ilechie
- Department of Optometry and Vision Science, University of Cape Coast, Ghana
| | - Naa Adjeley Addo
- Department of Optometry and Vision Science, University of Cape Coast, Ghana
| | - Elsie Aidoo
- Department of Optometry and Vision Science, University of Cape Coast, Ghana
| | - Anthony Armah
- Department of Optometry and Vision Science, University of Cape Coast, Ghana
| | - Fateena Faheem
- Department of Optometry and Vision Science, University of Cape Coast, Ghana
| | | |
Collapse
|
2
|
Sun R, Zhang J, Chen X, Deng Y, Gou J, Yin T, He H, Tang X, Ni X, Yang L, Zhang Y. An adaptive drug-releasing contact lens for personalized treatment of ocular infections and injuries. J Control Release 2024; 369:114-127. [PMID: 38521167 DOI: 10.1016/j.jconrel.2024.03.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 02/04/2024] [Accepted: 03/20/2024] [Indexed: 03/25/2024]
Abstract
This research introduces an innovative solution to address the challenges of bacterial keratitis and alkali burns. Current treatments for bacterial keratitis and alkali burns rely on the frequent use of antibiotics and anti-inflammatory eye drops. However, these approaches suffer from poor bioavailability and fluctuating concentrations, leading to limited efficacy and potential drug resistance. Our approach presents an adaptive drug-releasing contact lens responsive to reactive oxygen species (ROS) at ocular inflammation sites, synchronously releasing Levofloxacin and Diclofenac. During storage, minimal drug release occurred, but over 7 days of wear, the lens maintained a continuous, customizable drug release rate based on disease severity. This contact lens had strong antibacterial activity and biofilm prevention, effectively treating bacterial keratitis. When combined with autologous serum, this hydrophilic, flexible lens aids corneal epithelial regeneration, reducing irritation and promoting healing. In summary, this ROS-responsive drug-releasing contact lens combines antibacterial and anti-inflammatory effects, offering a promising solution for bacterial keratitis and alkali burns.
Collapse
Affiliation(s)
- Rong Sun
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Jie Zhang
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Xi Chen
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Yaxin Deng
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Jingxin Gou
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Tian Yin
- School of Chinese Materia Medica, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Haibing He
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Xing Tang
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China
| | - Xianpu Ni
- School of Life Science and Biopharmaceutics, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China.
| | - Li Yang
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China.
| | - Yu Zhang
- Department of Pharmaceutics, School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, Liaoning, PR China.
| |
Collapse
|
3
|
Itokawa T, Yamasaki K, Suzuki T, Koh S. Advances in Contact Lens Care Solutions: PVP-I Disinfectant and HAD Wetting Agents From Japan. Eye Contact Lens 2024; 50:91-101. [PMID: 38019569 DOI: 10.1097/icl.0000000000001060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/28/2023] [Indexed: 11/30/2023]
Abstract
ABSTRACT Half of the individuals who wear contact lenses use reusable lenses that require proper care. Improper contact lens (CL) care and using inadequate disinfecting solutions can lead to lens contamination, CL-related microbial keratitis, and Acanthamoeba keratitis. Oxidative disinfecting solutions, such as hydrogen peroxide, show higher efficacy than multipurpose solutions. Povidone-iodine (PVP-I), an oxidative disinfectant used in ophthalmic surgery, has been proven to be safe and effective. The PVP-I system, a CL disinfecting solution developed in Japan, has demonstrated excellent antimicrobial and antiviral properties. Although CL discomfort does not have a risk of ocular disorders with poor visual prognosis, such as keratitis, CL discomfort can still lead to lens dropout and thus needs to be addressed. To mitigate CL discomfort, it is essential to use disinfecting solutions containing surfactants and wetting agents that improve wettability of the lens surface. A CL solution containing hyaluronic acid derivatives (HADs) as wetting agents that permanently adhere to the lens surface to improve wettability of the lens surface was developed in Japan. There is potential for HAD to be integrated into various solutions. This article reviews the efficacy of novel PVP-I-based disinfecting solution and HAD wetting agents.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology (T.I., T.S.), Toho University, Tokyo, Japan; OPHTECS Corporation (K.Y.), Kobe Research Center, Kobe, Japan; Ishizuchi Eye Clinic (T.S.), Ehime, Japan; Department of Innovative Visual Science (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan; and Department of Ophthalmology (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan
| | | | | | | |
Collapse
|
4
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
5
|
Abstract
Ophthalmology is the branch of medicine that deals with diseases of the eye, the organ responsible for vision, and its attachments. Biomaterials can be made with different types of materials and can replace or improve a function or an organ, specifically the eye in the case of ophthalmic biomaterials. Biomaterials are substances that interact with biological systems for a medical purpose, either as a therapeutic (treat, augment, repair, or replace a tissue function of the body) or a diagnostic agent, and have continued to improve over the years, leading to the creation of new biomaterials. With the arrival of new generations, biomaterials have succeeded in reducing complications and toxicity and improving biocompatibilities associated with older generations. With the aging population, eye problems are becoming more prevalent, and biomaterials have helped in recent years to improve or restore vision, improving the quality of life of many patients. This review focuses on the most clinically used ophthalmic biomaterials, including contact lenses, intraocular lenses, artificial tears, inlays and vitreous replacements. Tissue engineering is presented as a new tool that is able to be treat several ophthalmologic disorders.
Collapse
|
6
|
Antiviral Activity of Contemporary Contact Lens Care Solutions against Two Human Seasonal Coronavirus Strains. Pathogens 2022; 11:pathogens11040472. [PMID: 35456147 PMCID: PMC9026382 DOI: 10.3390/pathogens11040472] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 04/04/2022] [Accepted: 04/12/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Given that reports have suggested SARS-CoV-2 can be transmitted via conjunctiva, the ability of contact lens (CL) care products to reduce the infectiousness of two seasonal human coronavirus (HCoV) (HCoV-229E and HCoV-OC43) surrogates for SARS-CoV-2 was investigated. Methods: Biotrue and Boston Simplus (Bausch&Lomb), OPTI-FREE Puremoist and Clear Care (Alcon), and cleadew and cleadew GP (Ophtecs) were tested. Their ability to inactivate HCoV was evaluated using contact times of 4 and 6 h as well as 1% and 10% of virus inoculum. Results: Non-oxidative systems (Biotrue, Boston Simplus, and OPTI-FREE) did not exhibit a significant log10 reduction compared to controls for the two viral strains for either incubation time (all p > 0.05) when 10% tests were performed. For the 1% test, while Boston Simplus and OPTI-FREE exhibited a significant log10 reduction of both HCoV-229E (after 6 h) and HCoV-OC43 (after either 4 or 6 h incubation), those products showed less than 1 log10 reduction of the two infectious viruses. Oxidative systems based on hydrogen peroxide or povidone-iodine showed a significant log10 reduction compared with the controls for both HCoV-229E and HCoV-OC43 in all tested conditions (all p < 0.01). Clear Care led to virus inactivation to below the limit of quantification for tests performed with 1% of inoculum after 6 h incubation, while cleadew and cleadew GP led to inactivation of the two viruses to below the limit of quantification in all tested conditions. Conclusion: Oxidative CL disinfection systems showed significant virucidal activity against HCoV-229E and HCoV-OC43, while non-oxidative systems showed minimal ability to inactivate the HCoV species examined.
Collapse
|
7
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
8
|
Bradley CS, Sicks LA, Pucker AD. Common Ophthalmic Preservatives in Soft Contact Lens Care Products: Benefits, Complications, and a Comparison to Non-Preserved Solutions. CLINICAL OPTOMETRY 2021; 13:271-285. [PMID: 34522149 PMCID: PMC8434857 DOI: 10.2147/opto.s235679] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 08/24/2021] [Indexed: 05/23/2023]
Abstract
PURPOSE Preservatives are essential for preventing contact lens (CL)-related microbial keratitis (MK). The purpose of this review is to summarize the current knowledge related to the use of common ophthalmic preservatives in CL care products with respect to both safety and efficacy. METHODS Manuscripts written in English were obtained by searching PubMed.gov with the term contact lens plus antimicrobial, benzalkonium chloride, biguanide, Aldox, polyquaternium, preservative, thimerosal, EDTA (ethylenediaminetetraacetic acid), chlorhexidine, or blister pack. RESULTS This review found that first-generation preservatives are no longer used in CL multipurpose solutions (MPS) due to their high levels of ocular toxicity. Modern, high-molecular-weight preservatives, including polyquaternium-1 (PQ-1) and biguanides (PHMB), are generally effective against bacteria, minimally effective against fungi, and not effective against Acanthamoeba. PQ-1 and PHMB are likely safe when used with CLs, but they may cause ocular adverse events, with roughly equal risk between the two preservatives. Some CL MPS contain both PQ-1 and PHMB, but no increased risk of adverse events has been reported when combining the two. Hydrogen-peroxide (H2O2) solutions are effective against all common ocular microbes, including Acanthamoeba, and they have been proven safe with proper compliance. Povidone-iodine (P-I) solutions are not currently commercially available in North America, but they have been shown in other countries to be safe and effective. CONCLUSION Patients should be monitored when using PQ-1 or PHMB-containing solutions since they have been associated with ocular adverse events. If events are detected, patients should be switched to an alternative solution. H2O2 or P-I solutions are preferred for any patient who may expose their CLs to water because they are the only solution categories effective against Acanthamoeba.
Collapse
Affiliation(s)
| | | | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
9
|
Supercritical CO 2 technology for one-pot foaming and sterilization of polymeric scaffolds for bone regeneration. Int J Pharm 2021; 605:120801. [PMID: 34139307 DOI: 10.1016/j.ijpharm.2021.120801] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 06/09/2021] [Accepted: 06/11/2021] [Indexed: 12/21/2022]
Abstract
Sterilization is a quite challenging step in the development of novel polymeric scaffolds for regenerative medicine since conventional sterilization techniques may significantly alter their morphological and physicochemical properties. Supercritical (sc) sterilization, i.e. the use of scCO2 as a sterilizing agent, emerges as a promising sterilization method due to the mild operational conditions and excellent penetration capability. In this work, a scCO2 protocol was implemented for the one-pot preparation and sterilization of poly(ε-caprolactone) (PCL)/poly(lactic-co-glycolic acid) (PLGA) scaffolds. The sterilization conditions were established after screening against both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli, Pseudomonas aeruginosa) vegetative bacteria and spores of Bacillus stearothermophilus, Bacillus pumilus and Bacillus atrophaeus. The transition from the sterilization conditions (140 bar, 39 °C) to the compressed foaming (60 bar, 26 °C) was performed through controlled depressurization (3.2 bar/min) and CO2 liquid flow. Controlled depressurization/pressurization cycles were subsequently applied. Using this scCO2 technology toolbox, sterile scaffolds of well-controlled pore architecture were obtained. This sterilization procedure successfully achieved not only SAL-6 against well-known resistant bacteria endospores but also improved the scaffold morphologies compared to standard gamma radiation sterilization procedures.
Collapse
|
10
|
Gammoh Y, Abdu M. Contact lens procurement and usage habits among adults in Sudan. PLoS One 2021; 16:e0251987. [PMID: 34010356 PMCID: PMC8133405 DOI: 10.1371/journal.pone.0251987] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 05/06/2021] [Indexed: 02/03/2023] Open
Abstract
Objective The study aimed to assess contact lens (CL) wear and care habits among adults in Sudan. Design An observational, non-interventional, multi-center, cross-sectional study was conducted in the CL departments of all the eye hospitals and centers, and optical centers in the Khartoum State, Sudan. Participants Established CL wearers residing in Khartoum State, Sudan. Main outcomes and measures CL wear profile, CL usage habits, hand and CL hygiene habits were assessed using an interviewer-administered questionnaire. Results The average age of the 442 participants was 24.57 (± 4.87) years. Women comprised 92% of the sample. Smoking was reported by 15.8% of the sample. 81.9% wore soft spherical CL, with 43.4% of the participants were prescribed CL on a yearly replacement schedule. Only 68.3% were prescribed CL by an eye care practitioner. Multipurpose solutions were used by 78.8% of the sample to clean CL, and by 52% to clean the lens case. Compliance rate for CL wear and care among participants was 81.1%. None of the participants reported sharing CL or CL case and rinsing the case with tap water. High compliance level was observed for overnight wear; swimming and showering with CL; handwashing before CL insertion; and cleaning of CL. Moderate compliance rates were recorded for cleaning and replacing lens case, and topping up or sharing solution. Low compliance was noted for attending after care visits. Conclusions and relevance CL wearers in Sudan exhibit high to moderate levels of compliance to most contact lens wear and care aspects, except for attending aftercare visits. CL practitioners in Sudan are encouraged to prescribe CL appropriate to the lifestyle and economic situation of patients and actively recommend care products. In addition, practitioners need to follow up with patients to attend aftercare appointments, where hygienic wear and care habits should be emphasized.
Collapse
Affiliation(s)
- Yazan Gammoh
- Faculty of Allied Medical Sciences, Department of Optometry Science, Al-Ahliyya Amman University, Amman, Jordan
- * E-mail:
| | - Mustafa Abdu
- Faculty of Optometry and Visual Sciences, Department of Contact Lenses, Al-Neelain University, Khartoum, Sudan
- Faculty of Applied Medical Sciences, Department of Optometry, University of Jeddah, Jeddah, KSA
| |
Collapse
|
11
|
Heynen M, Ng A, Martell E, Subbaraman LN, Jones L. Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems. Clin Ophthalmol 2021; 15:1727-1733. [PMID: 33935489 PMCID: PMC8079347 DOI: 10.2147/opth.s296116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 03/17/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activity of lysozyme deposited on worn senofilcon A, silicone hydrogel contact lenses. Participants and Methods Thirty symptomatic soft contact lens wearers were enrolled into a 4-week prospective, randomized, bilateral eye, daily-wear, crossover, double-masked study. Participants were fitted with biweekly senofilcon A lenses and were assigned either a polyquaternium-1 and myristamidopropyl dimethylamine-containing system (OPTI-FREE RepleniSH) or a peroxide-based system (CLEAR CARE). After each wear period, proteins were extracted from the lenses and analyzed for total protein, total lysozyme quantity and activity. Results The use of either the peroxide-based system or the polyquaternium-1 and myristamidopropyl dimethylamine-containing system resulted in no difference (P>0.05) to the amount of total protein deposited on the lenses (6.7 ± 2.8 micrograms/lens versus 7.3 ± 2.8 micrograms/lens, respectively) or to the amount of denatured lysozyme deposits (0.8 ± 0.7 versus 0.9 ± 0.7 micrograms/lens), respectively. The total amount of lysozyme deposited on the lenses was significantly lower when using the peroxide-based system (1.3 ± 0.9 micrograms/lens) compared to the polyquaternium-1 and myristamidopropyl dimethylamine-containing system (1.7 ± 1.0 micrograms/lens) (P=0.02). Conclusion The inactivation of lysozyme deposited on senofilcon A lenses when disinfected with the peroxide-based or the polyquaternium-1 and myristamidopropyl dimethylamine-containing systems were neither statistically nor clinically significant and the overall amounts of denatured lysozyme recovered from the lenses were low (<1 microgram/lens).
Collapse
Affiliation(s)
- Miriam Heynen
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Alan Ng
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Elizabeth Martell
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.,Centre for Eye and Vision Research (CEVR), Hong Kong Science Park, Hong Kong
| |
Collapse
|
12
|
Vincent SJ, Cho P, Chan KY, Fadel D, Ghorbani-Mojarrad N, González-Méijome JM, Johnson L, Kang P, Michaud L, Simard P, Jones L. CLEAR - Orthokeratology. Cont Lens Anterior Eye 2021; 44:240-269. [DOI: 10.1016/j.clae.2021.02.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/25/2022]
|
13
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
14
|
Wolffsohn JS, Dumbleton K, Huntjens B, Kandel H, Koh S, Kunnen CME, Nagra M, Pult H, Sulley AL, Vianya-Estopa M, Walsh K, Wong S, Stapleton F. CLEAR - Evidence-based contact lens practice. Cont Lens Anterior Eye 2021; 44:368-397. [PMID: 33775383 DOI: 10.1016/j.clae.2021.02.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Evidence-based contact lens -->practice involves finding, appraising and applying research findings as the basis for patient management decisions. These decisions should be informed by the strength of the research study designs that address the question, as well as by the experience of the practitioner and the preferences and environment of the patient. This reports reviews and summarises the published research evidence that is available to inform soft and rigid contact lens history and symptoms taking, anterior eye health examination (including the optimised use of ophthalmic dyes, grading scales, imaging techniques and lid eversion), considerations for contact lens selection (including the ocular surface measurements required to select the most appropriate lens parameter, lens modality and material selection), evaluation of lens fit, prescribing (teaching self-application and removal, adaptation, care regimen and cleaning instructions, as well as -->minimising risks of lens wear through encouraging compliance) and an aftercare routine.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- School of Optometry, University of California, Berkeley, CA, USA
| | - Byki Huntjens
- Division of Optometry and Visual Sciences at City, University of London, London, UK
| | - Himal Kandel
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Japan
| | | | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Cambridge, UK
| | - Heiko Pult
- Optometry and Vision Research, Weinheim, Germany
| | | | - Marta Vianya-Estopa
- Department of Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Karen Walsh
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Stephanie Wong
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
15
|
Yee A, Walsh K, Schulze M, Jones L. The impact of patient behaviour and care system compliance on reusable soft contact lens complications. Cont Lens Anterior Eye 2021; 44:101432. [PMID: 33678542 DOI: 10.1016/j.clae.2021.02.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 01/07/2021] [Accepted: 02/23/2021] [Indexed: 11/19/2022]
Abstract
Reusable soft daily wear contact lenses (CLs) remain popular and were fit to just over half of all wearers in the most recent international CL prescribing survey. Unlike daily disposable CLs, reusables require cleaning and disinfecting after every use, along with storage in a CL case. These additional requirements add a number of steps to the daily wear and care routine, increasing the opportunities for CL wearers to exhibit non-compliant behaviour. The impact of non-compliance ranges from poor lens comfort through to potentially sight-threatening infective keratitis. The coronavirus pandemic has refocused the profession on the importance of hand hygiene in particular, and the need for promoting safe CL wear in general. This review summarises typical non-compliant behaviour related to reusable CLs, and examines strategies and opportunities to better support wearers. Patient education has a central role in encouraging compliant behaviour, although patient recall of information is low, and personal belief systems may result in continuation of non-compliant behaviour despite awareness of the risks. CL care solutions are required for the daily disinfection of lenses, however misuse of multipurpose solutions (MPS) and hydrogen peroxide (H2O2)-based care systems can challenge their ability to be fully efficacious. Standard efficacy testing is reviewed, with consideration of how well current protocols model real-world use of CL solutions. Although some recommendations are in place for the inclusion of additional variables such as lens cases, CL materials, organic soil and efficacy against Acanthamoeba, opportunity still exists to reevaluate global standards to ensure consistency of testing in all markets. Finally, potential future innovations are discussed which may further support increased safety in reusable lens wear through novel antimicrobial additions to both CL materials and cases.
Collapse
Affiliation(s)
- Alan Yee
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| | - Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| | - Marc Schulze
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Canada.
| |
Collapse
|
16
|
Steele KR, Wagner H, Lai N, Zimmerman AB. Gas-Permeable Contact Lenses and Water Exposure: Practices and Perceptions. Optom Vis Sci 2021; 98:258-265. [PMID: 33771955 DOI: 10.1097/opx.0000000000001660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE This study provides insight into the current recommendations, clinical behaviors, and risk assessments of eye care professionals on the topic of rigid contact lens exposure to tap water. This knowledge may motivate professional organizations to develop initiatives to educate eye care professionals on the dangers of contact lens exposure to water. PURPOSE The purpose of this study was to investigate the practice patterns and risk perceptions of eye care professionals regarding gas-permeable contact lens exposure to tap water. METHODS A branched-logic survey was started by 320 clinicians, vision scientists, and industry personnel and was fully completed by 272 participants. The survey queried participants about their current practices, recommendations, and perceptions of risk regarding exposure of gas-permeable contact lenses to tap water. RESULTS Of those who prescribe gas-permeable contact lenses, 57.4% reported rinsing lenses with tap water, whereas only 32.7% reported engaging in this same behavior in front of patients. Of those who reported never rinsing lenses with tap water, 85.6% indicated that rinsing lenses with water increases infection risk, whereas 52.1% of those who rinse lenses with water reported the same perceived risk (P < .001). Of all participants, 60% indicated that wearing contact lenses while showering increases infection risk, and 50.2% of all participants advised patients to avoid this behavior. CONCLUSIONS A discrepancy exists between perceptions of risk concerning exposure of contact lenses to water and both clinical practices and patient education provided by professionals.
Collapse
Affiliation(s)
| | - Heidi Wagner
- The Ohio State University, College of Optometry, Columbus, Ohio
| | - Nicky Lai
- The Ohio State University, College of Optometry, Columbus, Ohio
| | | |
Collapse
|
17
|
Yamasaki K, Mizuno Y, Kitamura Y, McCanna DJ, Ngo W, Jones LW. The efficacy of povidone-iodine, hydrogen peroxide and a chemical multipurpose contact lens care system against Pseudomonas aeruginosa on various lens case surfaces. Cont Lens Anterior Eye 2021; 44:18-23. [DOI: 10.1016/j.clae.2020.02.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 02/18/2020] [Accepted: 02/20/2020] [Indexed: 10/24/2022]
|
18
|
Gabriel MM, McAnally C, Chen H, Srinivasan S, Manoj V, Garofalo R. Hydrogen Peroxide Disinfecting Solution for Gas Permeable Contact Lenses: A Review of the Antimicrobial Efficacy, Compatibility, and Safety Performance of a One-Step Lens Care System. CLINICAL OPTOMETRY 2021; 13:7-14. [PMID: 33469402 PMCID: PMC7813461 DOI: 10.2147/opto.s280046] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 11/19/2020] [Indexed: 06/12/2023]
Abstract
CLEAR CARE PLUS (CCP), also known as AOSEPT PLUS with HydraGlyde, is approved for use with gas permeable (GP) lenses, and the indication is supported by the scientific evidence that is reviewed in this article. Antimicrobial efficacy testing of CCP both as a stand-alone disinfectant and as part of a regimen shows that CCP exceeds the ISO 14729 criteria against bacteria, yeast, and mold. In real-world conditions, it is effective against clinically relevant bacterial strains isolated from adverse events and against the two forms, trophozoites and cysts, of resilient Acanthamoeba species. Compatibility tests of CCP with two types of GP lenses indicate that the physical and/or optical parameters of lenses are unaffected through 30 cycles of simulated use with CCP, and a clinical trial shows substantial equivalence of clinical performance with a commonly used GP multipurpose solution. These results indicate that CCP is well suited for cleaning and disinfection of GP contact lenses.
Collapse
Affiliation(s)
- Manal M Gabriel
- Research and Development, Alcon Research, LLC, Johns Creek, GA, USA
| | - Cynthia McAnally
- Research and Development, Alcon Research, LLC, Fort Worth, TX, USA
| | - Huagang Chen
- Research and Development, Alcon Research, LLC, Fort Worth, TX, USA
| | | | | | - Renee Garofalo
- Research and Development, Alcon Research, LLC, Fort Worth, TX, USA
| |
Collapse
|
19
|
Vianya-Estopa M, Garcia-Porta N, Piñero DP, Simo Mannion L, Beukes EW, Wolffsohn JS, Allen PM. Contact lens wear and care in Spain during the COVID-19 pandemic. Cont Lens Anterior Eye 2020; 44:101381. [PMID: 33246914 PMCID: PMC7657612 DOI: 10.1016/j.clae.2020.11.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 10/29/2020] [Accepted: 11/05/2020] [Indexed: 11/30/2022]
Abstract
AIM To establish contact lens wear and care practices during the COVID-19 pandemic in Spain. METHOD A 58-item anonymous online survey was distributed during the period 30th April to 10th May via Qualtrics. The survey explored: a) demographic characteristics (age, sex, general health and where they were living during lockdown), b) changes in their contact lens use during lockdown, c) hygiene and contact lens compliance and d) concerns associated with contact lens wear and ways to support wearers during the pandemic. RESULTS Two hundred and sixty responses were analysed (38.8 ± 11.4 years old, 75% female). Three-quarters of participants reported that they were self-isolating or rigorously following social distancing advice. Sixty-seven percent of participants reported using their contact lenses less during the pandemic. Respondents were found to be compliant with handwashing prior to inserting and removing contact lenses (in both cases 97% doing this 'most times' or 'every time'). However, only 44 % complied with the '20 s rule' and 48 % used a shared towel to dry their hands. A higher proportion of hydrogen peroxide users replaced the lens case monthly compared to multi-purpose users (64% vs.49%; p < 0.001). Twenty-four percent admitted wearing lenses whilst showering and 16% did not consider ceasing lens wear if feeling unwell with flu/cold symptoms. CONCLUSION Eye care practitioners should continue to educate contact lens wearers to ensure safe contact lens wear to minimise the chance of developing contact lens related complications during the pandemic. Modifiable factors that need particular attention in Spain include: handwashing for at least 20s before lens handling, drying hands with single use paper towels, including a rub-and-rinse step for reusable lenses, lens case cleaning and renewal, avoidance of water exposure and when to cease lens wear during the pandemic.
Collapse
Affiliation(s)
- Marta Vianya-Estopa
- Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK.
| | - Nery Garcia-Porta
- Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK.
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, Faculty of Science, University of Alicante, Alicante, Spain.
| | - Luisa Simo Mannion
- School of Health and Care Professions, University of Portsmouth, Portsmouth, UK.
| | - Eldre W Beukes
- Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK.
| | - James S Wolffsohn
- Optometry and Vision Science Research Group, Aston University, Birmingham, UK.
| | - Peter M Allen
- Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK.
| |
Collapse
|
20
|
Application of Histone Deacetylase Inhibitors MPK472 and KSK64 as a Potential Treatment Option for Acanthamoeba Keratitis. Antimicrob Agents Chemother 2020; 64:AAC.01506-20. [PMID: 32928736 DOI: 10.1128/aac.01506-20] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 09/06/2020] [Indexed: 12/12/2022] Open
Abstract
Treatment of Acanthamoeba keratitis (AK) is difficult because Acanthamoeba cysts are resistant to drugs, and as such, successful treatment requires an effective approach that inhibits cyst formation. Histone deacetylase inhibitors (HDACis) are involved in cell proliferation, differentiation, and apoptotic cell death. In this study, the effects of HDACis such as MPK472 and KSK64 on Acanthamoeba castellanii trophozoites and cysts were observed. MPK472 and KSK64 showed at least 60% amoebicidal activity against Acanthamoeba trophozoites at a concentration of 10 μM upon 8 h of treatment. Neither of the two HDACis affected mature cysts, but significant amoebicidal activities (36.4 and 33.9%) were observed against encysting Acanthamoeba following treatment with 5 and 10 μM HDACis for 24 h. Light microscopy and transmission electron microscopy results confirmed that the encystation of Acanthamoeba was inhibited by the two HDACis. In addition to this, low cytopathic effects on human corneal epithelial (HCE) cells were observed following treatment with MPK472 and KSK64 for 24 h. Our results indicate that the HDACis MPK472 and KSK64 could be used as new candidates for the development of an optimal therapeutic option for AK.
Collapse
|
21
|
Elgamouz A, Idriss H, Nassab C, Bihi A, Bajou K, Hasan K, Abu Haija M, Patole SP. Green Synthesis, Characterization, Antimicrobial, Anti-Cancer, and Optimization of Colorimetric Sensing of Hydrogen Peroxide of Algae Extract Capped Silver Nanoparticles. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1861. [PMID: 32957557 PMCID: PMC7557820 DOI: 10.3390/nano10091861] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 09/08/2020] [Accepted: 09/11/2020] [Indexed: 12/21/2022]
Abstract
A green and cost-effective technique for the preparation of silver nanoparticles (Algae-AgNPs) as a colorimetric sensor for hydrogen peroxide (H2O2) is described. Silver nanoparticles were capped using the green algae (Noctiluca scintillans) extract at an optimum time of 3 h at 80 °C. The pH of the plant extract (pH = 7.0) yields nanoparticles with a mean size of 4.13 nm and a zeta potential of 0.200 ± 0.02 mV and negative polarity, using dynamic light scattering (DLS). High-resolution transmission electron microscopy (HRTEM) analysis showed regular spherical particles with the average size of 4.5 nm. Selected area electron diffraction (SAED) results revealed the polycrystalline nature of the silver nanoparticles. The obtained patterns were indexed as (111), (200), (220), and (311) reflections of the fcc (face centered cubic) silver crystal based on their d-spacing of 2.47, 2.13, 1.49, and 1.27 Å, respectively. The apparent color change from brown to colorless was observed when nanoparticles reacted with H2O2. Linear responses were obtained in three different ranges (nM, µM, and mM). Limits of detection (LOD) of 1.33 ± 0.02 and 1.77 ± 0.02 nM and quantitation limits (LOQ) of 7.31 ± 0.03 and 9.67 ± 0.03 nM were obtained for Abs and ΔAbs calibration curves, respectively. 10% v/v Algae-AgNPs solution inhibited Staphylococcus aureus over Escherichia coli, while a 50% reduction of tumor cell growth of MDA-MB-231 human breast adenocarcinoma was obtained.
Collapse
Affiliation(s)
- Abdelaziz Elgamouz
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Hamid Idriss
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Chahlaa Nassab
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Alaa Bihi
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Khalid Bajou
- Department of Applied Biology, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE;
| | - Kamrul Hasan
- Department of Chemistry, College of Sciences, University of Sharjah, Sharjah PO. Box 27272, UAE; (H.I.); (C.N.); (A.B.); (K.H.)
| | - Mohammad Abu Haija
- Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi PO. Box 127788, UAE;
| | - Shashikant P. Patole
- Department of Physics, Khalifa University of Science and Technology, Abu Dhabi PO. Box 127788, UAE;
| |
Collapse
|
22
|
Sunaga T, Mimura T, Matsuoka H, Horikawa H, Kitsu K, Mizota A. Is Hydrogen Peroxide Disinfection Effective for Cleaning Pollen Particles Attached to Contact Lenses? CLINICAL OPTOMETRY 2020; 12:123-128. [PMID: 32904467 PMCID: PMC7455597 DOI: 10.2147/opto.s267871] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Accepted: 08/05/2020] [Indexed: 06/11/2023]
Abstract
PURPOSE It has been proven that wearing soft contact lenses (SCLs) can make pollen-induced allergic conjunctivitis worse. We investigated the cleaning effect of disinfectants and rinsing solution on cedar pollen attached to SCLs. METHODS Two-week replacement disposable SCLs, to which pollen particles were experimentally attached, were washed and cleaned with either saline of rinsing solution (n = 10) or 3% hydrogen peroxide (n = 10). We observed, under a microscope, the cedar pollen adhered to the SCLs after washing. RESULTS The number of residual pollens attached to SCLs was 23.7 ± 25.7 with rinsing solution and 0.2 ± 0.6 with 3% hydrogen peroxide solution per single area (100 µm × 100 µm). The percentage of adhesion area of pollen to the SCLs was 0.9 ± 1.1% with rinsing solution and 0.0 ± 0.0% with 3% hydrogen peroxide solution. There were significant differences in the number of pollen and adhesion areas of pollen between the two groups (p < 0.05 and p < 0.05, respectively). CONCLUSION These results suggest that hydrogen peroxide solution is superior in cleaning effect of cedar pollen attached to SCLs compared to saline.
Collapse
Affiliation(s)
- Takahiro Sunaga
- Department of Ophthalmology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan
- Teikyo University of Science & Technology, Senju Campus 7, Adachi-ku, Tokyo, Japan
| | - Tatsuya Mimura
- Department of Ophthalmology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan
| | - Hiroshi Matsuoka
- Teikyo University of Science & Technology, Senju Campus 7, Adachi-ku, Tokyo, Japan
| | - Hiroaki Horikawa
- Department of Ophthalmology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan
| | - Kazuma Kitsu
- Department of Ophthalmology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan
| | - Atsushi Mizota
- Department of Ophthalmology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan
| |
Collapse
|
23
|
Shen EP, Chu HS, Hsieh YT, Chen WL, Chang SC, Hu FR. Analysis of P. aeruginosa disinfectant sensitivity and microbial adhesions to worn cosmetic contact lenses. Cont Lens Anterior Eye 2020; 43:338-344. [DOI: 10.1016/j.clae.2019.10.137] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 10/15/2019] [Accepted: 10/27/2019] [Indexed: 12/22/2022]
|
24
|
Combination of tert-butyl hydroperoxide with vorinostat induces cell death of Acanthamoeba through cell cycle arrest. Exp Parasitol 2020; 210:107833. [PMID: 31935358 DOI: 10.1016/j.exppara.2020.107833] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 12/06/2019] [Accepted: 01/10/2020] [Indexed: 11/20/2022]
Abstract
Safety precautions prior to contact lens usage is essential for preventing Acanthamoeba keratitis. Contact lens disinfecting solutions containing 3% hydrogen peroxide (H2O2) are known to exert amoebicidal effect against Acanthamoeba. Yet, these solutions need to be neutralized to prevent ocular irritation, which consequently may result in incomplete disinfection. In this study, amoebicidal effect of tert-butyl hydroperoxide (tBHP) was investigated and its efficacy was compared to those of hydrogen peroxide (H2O2). H2O2 and tBHP showed dose dependent amoebicidal effect, however high concentration of these compounds demonstrated cytotoxicity in human corneal epithelial (HCE) cells. To reduce their cytotoxicity, the concentrations of both compounds were diluted to 50 μM and subsequently combined with 10 μM vorinostat to enhance amoebicidal effect. Addition of vorinostat induced high amoebicidal effect against Acanthamoeba trophozoites, even at low concentrations of H2O2 or tBHP. Cellular damage induced by combined treatment of H2O2 or tBHP with vorinostat in Acanthamoeba were determined by assessing cell cycle arrest and apoptosis via FACS analysis. While 50 μM H2O2 combined with 10 μM vorinostat showed 36.26% cytotoxicity on HCE cells during 24 h exposure, 50 μM tBHP with 10 μM vorinostat did not show cytotoxicity on HCE cells. These findings suggest that the application of tBHP and vorinostat for Acanthamoeba keratitis treatment and contact lens disinfection system is highly plausible.
Collapse
|
25
|
Cho P, Poon HY, Chen CC, Yuon LT. To rub or not to rub? - effective rigid contact lens cleaning. Ophthalmic Physiol Opt 2019; 40:17-23. [PMID: 31755140 DOI: 10.1111/opo.12655] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2019] [Accepted: 10/30/2019] [Indexed: 11/28/2022]
Abstract
PURPOSE To compare the efficacy of cleaning of rigid contact lenses using two care solutions with and without rubbing. METHODS A masked randomised trial was conducted. The cleaning efficacy of two solutions recommended for rigid contact lenses, a one-step hydrogen peroxide solution (HP) and a povidone iodine-based solution (PI), were evaluated on 64 unworn orthokeratology (ortho-k) lenses subsequent to cleaning with rubbing (R) with a surfactant cleaner or without rubbing (NR). Either mascara or hand cream was applied as a contaminant to the lenses to simulate stubborn and loosely bounded deposits, respectively. For each type of deposit, the lenses were randomly assigned to four cleaning treatments: R with HP, NR with HP, R with PI, and NR with PI (n = 8 for each group). Each lens surface was assessed on site by a masked examiner under a low-magnification slit-lamp and with photo-documentation. Lenses were graded according to the deposit coverage area using a pre-set five-point scale [0 (<20% coverage) - 4 (>80% coverage)]. RESULTS For stubborn deposits (mascara), NR failed to remove deposits from 94% of lenses, whilst R removed more than 80% of deposits from 63% of the lenses. For oily deposits, 25% of NR lenses had >80% coverage, whilst only one R lens had 60-80% coverage, with 19% having 40-60% coverage, and 38% with either 20-40% or <20%. Rubbing improved lens cleanliness for both types of deposits, but only reached statistical significance for the stubborn deposit group. There were no significant differences between the solutions. CONCLUSION Not Rubbing and using either HP or PI solutions, is not effective in removing stubborn deposits from ortho-k lenses. It is essential to rub lenses when cleaning rigid lenses to ensure optimal lens hygiene for ocular health, especially as rigid gas permeable (RGP) lenses are intended to be reused for at least a year before replacement. Rubbing with a daily cleaner should be included in the instructions for use of the solutions tested for rigid lenses and practitioners should be encouraged to emphasise the importance of rubbing in lens care.
Collapse
Affiliation(s)
- Pauline Cho
- School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| | - Hoi Ying Poon
- School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| | - Chia Ching Chen
- School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| | - Lien Tao Yuon
- School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| |
Collapse
|