Goffi-Gomez MVS, Corrêa FMDS, Magalhães AT, Hoshino AC, Samuel P, Sadowski T, Colalto C, Tsuji RK, Brito Neto R. Is the spread of excitation different between adults and children cochlear implants users? Eur Arch Otorhinolaryngol 2024; 281:3491-3498. [PMID: 38240771 DOI: 10.1007/s00405-024-08451-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 01/02/2024] [Indexed: 06/29/2024]
Abstract
PURPOSE While cochlea is adult size at birth, etiologies and bone density may differ between children and adults. Differences in neural response thresholds (tNRT) and the spread of excitation (SOE) width may impact the use of artificial intelligence algorithms in speech processor fitting. AIM To identify whether neural response telemetry threshold and spread of excitation width are similar in adults and children. METHODS Retrospective cross-sectional study approved by the Ethical Board. Intraoperative tNRT and SOE recordings of consecutive cochlear implant surgeries in adults and children implanted with Cochlear devices (Cochlear™, Australia) were selected. SOE was recorded on electrode 11 (or adjacent, corresponding to the medial region of the cochlea) through the standard forward-masking technique in Custom Sound EP software, which provides SOE width in millimeters. Statistical comparison between adults and children was performed using the Mann-Whitney test (p ≤ 0.05). RESULTS Of 1282 recordings of intraoperative evaluations, 414 measurements were selected from children and adults. Despite the tNRT being similar between adults and children, SOE width was significantly different, with lower values in children with perimodiolar arrays. Besides, it was observed that there is a difference in the electrode where the SOE function peak occurred, more frequently shifted to electrode 12 in adults implanted. In straight arrays, there was no difference in any of the parameters analyzed on electrode 11. CONCLUSION Although eCAP thresholds are similar, SOE measurements differ between adults and children in perimodiolar electrodes.
Collapse
Affiliation(s)
- Maria Valéria Schmidt Goffi-Gomez
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil.
| | - Francyelle Machado da Silva Corrêa
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Ana Tereza Magalhães
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Ana Cristina Hoshino
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Paola Samuel
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Tatiana Sadowski
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Claudia Colalto
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Robinson Koji Tsuji
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| | - Rubens Brito Neto
- ENT Department, Cochlear Implant Group at Clinical Hospital of the Medical School at University of São Paulo, Av. Dr. Eneas de Carvalho Aguiar 255, São Paulo, Brazil
| |
Collapse
|
2
|
Sharma V, Das K N, Jangra A, Tiwari S, Khera P, Soni K, Dixit SG, Nayyar AK, Goyal A. Dependability of Electrode to Modiolus Distance in Patients Specific Electrode Selection: A Cadaveric Model Study. Laryngoscope 2024. [PMID: 38860484 DOI: 10.1002/lary.31565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 04/29/2024] [Accepted: 05/28/2024] [Indexed: 06/12/2024]
Abstract
OBJECTIVE This study aims to discern the disparities in the electrode-to-modiolus distance (EMD) between cochleostomy and round window approaches when performed sequentially in the same temporal bone. Additionally, the study seeks to identify the cochlear metrics that contribute to these differences. METHODOLOGY A cross-sectional study was conducted, involving the sequential insertion of a 12-electrode array through both round window and cochleostomy approaches in cadaveric temporal bones. Postimplantation high-resolution CT scans were employed to calculate various parameters. RESULTS A total of 12 temporal bones were included in the imaging analysis, revealing a mean cochlear duct length of 32.892 mm. The EMD demonstrated a gradual increase from electrode 1 (C1) in the apex (1.9 ± 0.07 mm; n = 24) to electrode 12 (C12) in the basal turn (4.6 ± 0.24 mm; n = 12; p < 0.01). Significantly higher EMD values were observed in the cochleostomy group. Correlation analysis indicated a strong positive correlation between EMD and cochlear perimeter (CP) (rs = 0.64; n = 12; p = 0.03) and a strong negative correlation with the depth of insertion (DOI) in both the middle and basal turns (rs = - 0.78; n = 20; p < 0.01). Additionally, EMD showed a strong negative correlation with the DOI-CP ratio (rs = -0.81; n = 12; p < 0.01). CONCLUSION The cochleostomy group exhibited a significantly higher EMD compared with the round window group. The strong negative correlation between EMD and DOI-CP ratio suggests that in larger cochleae with shallower insertions, EMD is greater than in smaller cochleae with deeper insertions. LEVEL OF EVIDENCE N/A Laryngoscope, 2024.
Collapse
Affiliation(s)
- Vidhu Sharma
- Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India
| | - Nidhin Das K
- Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India
| | - Anupriya Jangra
- Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India
| | - Sarbesh Tiwari
- Department of Diagnostic and Interventional, Radiology, All India Institute of Medical Sciences, Jodhpur, India
| | - Pushpinder Khera
- Department of Diagnostic and Interventional, Radiology, All India Institute of Medical Sciences, Jodhpur, India
| | - Kapil Soni
- Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India
| | - Shilpi G Dixit
- Department of Anatomy, All India Institute of Medical Sciences, Jodhpur, India
| | - Ashish K Nayyar
- Department of Anatomy, All India Institute of Medical Sciences, Jodhpur, India
| | - Amit Goyal
- Department of Otorhinolaryngology, All India Institute of Medical Sciences, Jodhpur, India
| |
Collapse
|
3
|
Eitutis ST, Vickers DA, Tebbutt K, Thomas T, Jiang D, de Klerk A, Clemesha J, Chung M, Bance ML. A Multicenter Comparison of 1-yr Functional Outcomes and Programming Differences Between the Advanced Bionics Mid-Scala and SlimJ Electrode Arrays. Otol Neurotol 2023; 44:e730-e738. [PMID: 37889939 PMCID: PMC10662583 DOI: 10.1097/mao.0000000000004048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/29/2023]
Abstract
OBJECTIVE To determine if there is a difference in hearing outcomes or stimulation levels between Advanced Bionics straight and precurved arrays. STUDY DESIGN Retrospective chart review across three implant centers. SETTING Tertiary centers for cochlear and auditory brainstem implantation. PATIENTS One hundred fifteen pediatric and 205 adult cochlear implants (CIs) were reviewed. All patients were implanted under the National Institute for Health and Care Excellence 2009 guidelines with a HiRes Ultra SlimJ or Mid-Scala electrode array. MAIN OUTCOME MEASURES Hearing preservation after implantation, as well as CI-only listening scores for Bamford-Kowal-Bench sentences were compared 1 year after implantation. Stimulation levels for threshold and comfort levels were also compared 1 year after implantation. RESULTS Hearing preservation was significantly better with the SlimJ compared with the Mid-Scala electrode array. Bamford-Kowal-Bench outcomes were not significantly different between the two arrays in any listening condition. Stimulation levels were not different between arrays but did vary across electrode contacts. At least one electrode was deactivated in 33% of implants but was more common for the SlimJ device. CONCLUSION Modern straight and precurved arrays from Advanced Bionics did not differ in hearing performance or current requirements. Although hearing preservation was possible with both devices, the SlimJ array would still be the preferred electrode in cases where hearing preservation was a priority. Unfortunately, the SlimJ device was also prone to poor sound perception on basal electrodes. Further investigation is needed to determine if deactivated electrodes are associated with electrode position/migration, and if programming changes are needed to optimize the use of these high-frequency channels.
Collapse
Affiliation(s)
- Susan T. Eitutis
- Emmeline Centre, Cambridge University Hospitals NHS Foundation Trust
- Cambridge Hearing Group, Department of Clinical Neurosciences, Cambridge Biomedical Campus, University of Cambridge
| | - Deborah A. Vickers
- Sound Laboratory, Cambridge Hearing Group, Clinical Neurosciences, University of Cambridge, Cambridge
| | | | | | - Dan Jiang
- Guy's and St. Thomas' NHS Foundation Trust
| | | | - Jennifer Clemesha
- Auditory Implant Department, Royal National ENT & Eastman Dental Hospitals, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Mark Chung
- Auditory Implant Department, Royal National ENT & Eastman Dental Hospitals, University College London Hospitals NHS Foundation Trust, London, United Kingdom
| | - Manohar L. Bance
- Cambridge Hearing Group, Department of Clinical Neurosciences, Cambridge Biomedical Campus, University of Cambridge
| |
Collapse
|
4
|
Ding L, Zhang L, Li J, Lin T. Electrode-Modiolus Distance Affects Speech Perception for Lateral Wall Electrodes. Otol Neurotol 2023; 44:e702-e709. [PMID: 37939358 DOI: 10.1097/mao.0000000000004019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
OBJECTIVES The goal of this study was to use cone-beam computed tomography to locate the electrode-modiolus distance (EMD) and correlate this with speech perception in cochlear implant (CI) recipients of the 31.5-mm lateral wall (LW) electrode arrays. STUDY DESIGN Retrospective review. PATIENTS Forty-five child CI recipients with prelingual profound sensorineural hearing loss of inserted 31.5-mm LW arrays listening with a CI-alone device. INTERVENTIONS Stepwise forward multiple linear regression was performed to control and reduce the variability in implant performance to determine whether EMD affects speech perception. MAIN OUTCOME MEASURES Electrode location (angular insertion depth [AID], EMD), together with the electrode impedance (EI), surgical approach, sex, CI age, and preimplant hearing aid usage were estimated as independent variables. The dependent variables were the Meaningful Use of Speech Scale (MUSS) and parents' evaluation of children's aural/oral performance (PEACH) assessed with the CI alone at 12 months postactivation. RESULTS EMD and CI age were predictive variables for PEACH/MUSS. A negative correlation was found between AID and EMD (r = -0.56, p < 0.01), whereas EMD had a moderately positive correlation with EI (r = 0.32, p < 0.01). CONCLUSIONS The best "location-related" predictor of postoperative speech perception was EMD with a 31.5-mm array among CI-alone users.
Collapse
Affiliation(s)
- Ling Ding
- Department of Otorhinolaryngology-Head and Neck Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Luguang Zhang
- Department of Medical Imaging, The Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Jing Li
- Department of Otorhinolaryngology-Head and Neck Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Tao Lin
- Department of Neurosurgery, Shandong Second Provincial General Hospital, Jinan, Shandong, 250022, China
| |
Collapse
|
5
|
Berg KA, Chen C, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Effects of the Number of Channels and Channel Stimulation Rate on Speech Recognition and Sound Quality Using Precurved Electrode Arrays. Am J Audiol 2023; 32:403-416. [PMID: 37249492 PMCID: PMC10468116 DOI: 10.1044/2023_aja-22-00032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 06/16/2022] [Accepted: 02/05/2023] [Indexed: 05/31/2023] Open
Abstract
PURPOSE This study investigated the relationship between the number of active electrodes, channel stimulation rate, and their interaction on speech recognition and sound quality measures while controlling for electrode placement. Cochlear implant (CI) recipients with precurved electrode arrays placed entirely within scala tympani and closer to the modiolus were hypothesized to be able to utilize more channels and possibly higher stimulation rates to achieve better speech recognition performance and sound quality ratings than recipients in previous studies. METHOD Participants included seven postlingually deafened adult CI recipients with Advanced Bionics Mid-Scala electrode arrays confirmed to be entirely within scala tympani using postoperative computerized tomography. Twelve conditions were tested using four, eight, 12, and 16 electrodes and channel stimulation rates of 600 pulse per second (pps), 1,200 pps, and each participant's maximum allowable rate (1,245-4,800 pps). Measures of speech recognition and sound quality were acutely assessed. RESULTS For the effect of channels, results showed no significant improvements beyond eight channels for all measures. For the effect of channel stimulation rate, results showed no significant improvements with higher rates, suggesting that 600 pps was sufficient for maximum speech recognition performance and sound quality ratings. However, across all conditions, there was a significant relationship between mean electrode-to-modiolus distance and all measures, suggesting that a lower mean electrode-to-modiolus distance was correlated with higher speech recognition scores and sound quality ratings. CONCLUSION These findings suggest that even well-placed precurved electrode array recipients may not be able to take advantage of more than eight channels or higher channel stimulation rates (> 600 pps), but that closer electrode array placement to the modiolus correlates with better outcomes for these recipients.
Collapse
Affiliation(s)
- Katelyn A. Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| | - Chen Chen
- Research and Technology, Advanced Bionics, LLC, Valencia, CA
| | - Jack H. Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN
| | - Benoit M. Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN
| | - Robert T. Dwyer
- Research and Technology, Advanced Bionics, LLC, Valencia, CA
| | - Robert F. Labadie
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston
| | - René H. Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| |
Collapse
|
6
|
Mussoi BS, Woodson E, Sydlowski S. Intraoperative Electrically Evoked Compound Action Potential Growth and Maximum Amplitudes in Hearing Preservation Cochlear Implant Recipients. Otol Neurotol 2023; 44:e216-e222. [PMID: 36946363 DOI: 10.1097/mao.0000000000003829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
BACKGROUND Electrically evoked compound action potentials (eCAPs) obtained from cochlear implant (CI) recipients reflect responsiveness of the auditory nerve to electrical stimulation. The recent use of atraumatic electrode arrays and expansion of CI candidacy to listeners with greater residual hearing may lead to increased clinical utility of intraoperative eCAP recordings. OBJECTIVES To examine the effect of electrode array (slim modiolar versus slim straight) on suprathreshold intraoperative eCAP recordings in hearing preservation CI recipients. A secondary goal was to examine potential clinical applications of intraoperative eCAPs for predicting immediate hearing preservation and speech perception outcomes. METHODS Retrospective study of 113 adult hearing preservation CI candidates implanted from 2015 to 2019 with either a slim modiolar or slim straight electrode array. Intraoperative eCAP growth functions and maximum amplitudes were obtained at several intracochlear electrodes and examined as a function of implanted array and hearing preservation status, while controlling for electrode impedance. RESULTS From basal to apical electrodes, progressively larger eCAP amplitudes and steeper slopes were recorded. Steeper eCAP slopes at apical electrodes were also seen for recipients of the slim modiolar array (versus slim straight). Suprathreshold eCAP responses did not differ as a function of hearing preservation and were not associated with speech recognition. CONCLUSIONS More robust eCAP responses were obtained from apical electrodes, which is consistent with better low-frequency thresholds in hearing preservation recipients. This effect was compounded by type of electrode array. Results also suggest that intraoperative, suprathreshold eCAPs cannot be used to predict the success of hearing preservation surgery or performance with the CI.
Collapse
Affiliation(s)
- Bruna S Mussoi
- Speech Pathology and Audiology, Kent State University, Kent, Kaiser Permanente Southern California, San Diego, CA
| | - Erika Woodson
- Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio
| | | |
Collapse
|
7
|
Smetak MR, Riojas KE, Whittenbarger N, Noble JH, Labadie RF. Dynamic Behavior and Insertional Forces of a Precurved Electrode Using the Pull-Back Technique in a Fresh Microdissected Cochlea. Otol Neurotol 2023; 44:324-330. [PMID: 36728107 PMCID: PMC10038836 DOI: 10.1097/mao.0000000000003812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
HYPOTHESIS This study evaluated the utility of the pull-back technique in improving perimodiolar positioning of a precurved cochlear implant (CI) electrode array (EA) with simultaneous insertion force profile measurement and direct observation of dynamic EA behavior. BACKGROUND Precurved EAs with perimodiolar positioning have improved outcomes compared with straight EAs because of lowered charge requirements for stimulation and decreased spread of excitation. The safety and efficacy of the pull-back technique in further improving perimodiolar positioning and its associated force profile have not been adequately demonstrated. METHODS The bone overlying the scala vestibuli was removed in 15 fresh cadaveric temporal bones, leaving the scala tympani unviolated. Robotic insertions of EAs were performed with simultaneous force measurement and video recording. Force profiles were obtained during standard insertion, overinsertion, and pull-back. Postinsertion CT scans were obtained during each of the three conditions, enabling automatic segmentation and calculation of angular insertion depth, mean perimodiolar distance ( Mavg ), and cochlear duct length. RESULTS Overinsertion did not result in significantly higher peak forces than standard insertion (mean [SD], 0.18 [0.06] and 0.14 [0.08] N; p = 0.18). Six temporal bones (40%) demonstrated visibly improved perimodiolar positioning after the protocol, whereas none worsened. Mavg significantly improved after the pull-back technique compared with standard insertion (mean [SD], 0.34 [0.07] and 0.41 [0.10] mm; p < 0.01). CONCLUSIONS The pull-back technique was not associated with significantly higher insertional forces compared with standard insertion. This technique was associated with significant improvement in perimodiolar positioning, both visually and quantitatively, independent of cochlear size.
Collapse
Affiliation(s)
- Miriam R. Smetak
- Department of Otolaryngology – Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, TN
| | | | - Noah Whittenbarger
- Department of Otolaryngology – Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, TN
| | - Jack H. Noble
- Department of Electrical Engineering & Computer Science, Vanderbilt University, Nashville, TN
| | - Robert F. Labadie
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, SC
| |
Collapse
|
8
|
Lambriks L, van Hoof M, Debruyne J, Janssen M, Hof J, Hellingman K, Devocht E, George E. Toward neural health measurements for cochlear implantation: The relationship among electrode positioning, the electrically evoked action potential, impedances and behavioral stimulation levels. Front Neurol 2023; 14:1093265. [PMID: 36846130 PMCID: PMC9948626 DOI: 10.3389/fneur.2023.1093265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/10/2023] [Indexed: 02/11/2023] Open
Abstract
Introduction Estimating differences in neural health across different sites within the individual cochlea potentially enables clinical applications for subjects with a cochlear implant. The electrically evoked compound action potential (ECAP) is a measure of neural excitability that possibly provides an indication of a neural condition. There are many factors, however, that affect this measure and increase the uncertainty of its interpretation. To better characterize the ECAP response, its relationship with electrode positioning, impedances, and behavioral stimulation levels was explored. Methods A total of 14 adult subjects implanted with an Advanced Bionics cochlear electrode array were prospectively followed up from surgery to 6 months postoperative. Insertion depth, distance to the modiolus, and distance to the medial wall were assessed for each electrode by postoperative CT analysis. ECAPs were measured intraoperatively and at three visits postoperatively on all 16 electrodes using the NRI feature of clinical programming software and characterized using multiple parameters. Impedances and behavioral stimulation levels were measured at every fitting session. Results Patterns in ECAPs and impedances were consistent over time, but high variability existed among subjects and between different positions in the cochlea. Electrodes located closer to the apex of the cochlea and closer to the modiolus generally showed higher neural excitation and higher impedances. Maximum loudness comfort levels were correlated strongly with the level of current needed to elicit a response of 100 μV ECAP. Conclusion Multiple factors contribute to the ECAP response in subjects with a cochlear implant. Further research might address whether the ECAP parameters used in this study will benefit clinical electrode fitting or the assessment of auditory neuron integrity.
Collapse
Affiliation(s)
- Lars Lambriks
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,*Correspondence: Lars Lambriks ✉
| | - Marc van Hoof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Joke Debruyne
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Miranda Janssen
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,Department of Methodology and Statistics, Care and Public Health Research Institute, Maastricht University, Maastricht, Netherlands
| | - Janny Hof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Katja Hellingman
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Elke Devocht
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Erwin George
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| |
Collapse
|
9
|
Slim Modiolar Electrode Placement in Candidates for Electroacoustic Stimulation. Ear Hear 2022; 44:566-571. [PMID: 36534657 DOI: 10.1097/aud.0000000000001304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
OBJECTIVES To determine rates of hearing preservation and performance in patients who met candidacy for electroacoustic stimulation (EAS) and were implanted with a slim modiolar electrode (CI532 or CI632). DESIGN Adult patients meeting Food and Drug Administration criteria for electroacoustic stimulation (preoperative low-frequency pure-tone average [LFPTA] less than 60 dB at 125, 250, and 500 Hz and monosyllabic word scores between 10% and 60% in the ear to be implanted), who received a slim modiolar electrode were included. Main outcome measures included rates of hearing preservation, defined as a LFPTA ≤80 dB at 125, 250, and 500 Hz, as well as postoperative low-frequency pure-tone threshold shifts, consonant-Nucleus-Consonant (CNC) word scores and AzBio sentences in noise scores. RESULTS Forty-six patients met inclusion criteria during a 4-year period. Mean (standard deviation) preoperative LFPTA was 34.5 (13.0) dB, and 71.7% had preserved hearing at initial activation. The mean LFPTA shift in patients who preserved hearing at initial activation was 19.7 (14.6) dB, compared with 62.6 (17.7) dB in patients who did not preserve hearing as per our definition. Perioperative steroid use was not different in patients with and without preserved hearing (X 2 (1, N = 46) = 0.19, p = .67, V = 0.06). One year after surgery, 57% of patients had a decline in LFPTA >80 dB and were no longer considered candidates for EAS, with 34.7% still retaining low-frequency thresholds ≤80 dB. CNC word scores at 1 year were 69.9% and 61.4% among individuals with and without preserved low-frequency hearing respectively, measured in their CI ear alone, in their regular listening condition of EAS or electric only ( t (32) = 1.13, p = 0.27, d = 0.39, 95% CI = -6.51, 22.86). Device use time did not differ between groups. Among adults with preserved residual hearing at 1 year (n = 16), 44% used EAS, although there was no significant difference in performance between EAS users and nonusers with preserved hearing. Loss of residual hearing over time did not result in a decline in speech perception performance. CONCLUSION The present study demonstrated favorable early rates of hearing preservation with a slim modiolar array. Performance was not significantly different in individuals with and without preserved low-frequency acoustic hearing, independent of EAS use. Compared with reports of short electrode use, the loss of residual hearing in patients implanted with this array did not impact speech perception performance.
Collapse
|
10
|
Söderqvist S, Sinkkonen ST, Sivonen V. The intraoperative relationship between intracochlear electrical field and excitability of the auditory nerve. Heliyon 2022; 8:e11970. [DOI: 10.1016/j.heliyon.2022.e11970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 10/10/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022] Open
|
11
|
Sharma RK, Smetak MR, Patro A, Lindquist NR, Perkins EL, Holder JT, Haynes DS, Tawfik KO. Speech Recognition Performance Differences Between Precurved and Straight Electrode Arrays From a Single Manufacturer. Otol Neurotol 2022; 43:1149-1154. [PMID: 36201525 DOI: 10.1097/mao.0000000000003703] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Precurved cochlear implant (CI) electrode arrays have demonstrated superior audiometric outcomes compared with straight electrodes in a handful of studies. However, previous comparisons have often failed to account for preoperative hearing and age. This study compares hearing outcomes for precurved and straight electrodes by a single manufacturer while controlling for these and other factors in a large cohort. STUDY DESIGN Retrospective cohort study. SETTING Tertiary academic medical center. PATIENTS Two hundred thirty-one adult CI recipients between 2015 and 2021 with cochlear (Sydney, Australia) 522/622 (straight) or 532/632 (precurved) electrode arrays. INTERVENTIONS Postactivation speech recognition and audiometric testing. MAIN OUTCOME MEASURES Speech recognition testing (consonant-nucleus-consonant word [CNCw] and AzBio) was collected at 6 and 12 months postactivation. Hearing preservation was characterized by a low-frequency pure-tone average shift, or the change between preoperative and postoperative low-frequency pure-tone average. RESULTS Two hundred thirty-one patients (253 ears) with 6-month and/or 12-month CNCw or AzBio testing were included. One hundred forty-nine (59%) and 104 (41%) ears were implanted with straight and precurved electrode arrays, respectively. Average age at implantation was 70 years (interquartile range [IQR], 58-77 y). There was no significant difference in mean age between groups. CNCw scores were significantly different ( p = 0.001) between straight (51%; IQR, 36-67%) and precurved arrays (64%; IQR, 48-72%). AzBio scores were not significantly different ( p = 0.081) between straight (72%; IQR, 51-87%) and precurved arrays (81%; IQR, 57-90%). Controlling for age, race, sex, preoperative hearing, and follow-up time, precurved electrode arrays performed significantly better on CNCw (b = 10.0; 95% confidence interval, 4.2-16.0; p < 0.001) and AzBio (b = 8.9; 95% confidence interval, 1.8-16.0;, p = 0.014) testing. Hearing preservation was not different between electrodes on adjusted models. CONCLUSION During the study period, patients undergoing placement of precurved electrode arrays had significantly higher CNC and AzBio scores than patients receiving straight electrodes, even after controlling for age, preoperative hearing, and follow-up time. PROFESSIONAL PRACTICE GAP AND EDUCATIONAL NEED Understanding the difference in audiometric outcomes between precurved and straight electrode arrays will help to guide electrode selection. LEARNING OBJECTIVE To understand differences in speech recognition scores postoperatively by electrode array type (precurved versus straight). DESIRED RESULT To demonstrate a difference in hearing performance postoperatively by electrode type. LEVEL OF EVIDENCE III. INDICATE IRB OR IACUC Approved by the Institutional IRB (090155).
Collapse
Affiliation(s)
- Rahul K Sharma
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Miriam R Smetak
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Ankita Patro
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Nathan R Lindquist
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Elizabeth L Perkins
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | | | - David S Haynes
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Kareem O Tawfik
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| |
Collapse
|
12
|
Bratu EL, Sunderhaus LW, Berg KA, Dwyer RT, Labadie RF, Gifford RH, Noble JH. Activation region overlap visualization for image-guided cochlear implant programming. Biomed Phys Eng Express 2022; 9:10.1088/2057-1976/ac9aba. [PMID: 36594887 PMCID: PMC10072294 DOI: 10.1088/2057-1976/ac9aba] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 10/17/2022] [Indexed: 11/24/2022]
Abstract
Objective. The cochlear implant is a neural prosthesis designed to directly stimulate auditory nerve fibers to induce the sensation of hearing in those experiencing severe-to-profound hearing loss. After surgical implantation, audiologists program the implant's external processor with settings intended to produce optimal hearing outcomes. The likelihood of achieving optimal outcomes increases when audiologists have access to tools that objectively present information related to the patient's own anatomy and surgical outcomes. This includes visualizations like the one presented here, termed the activation region overlap image, which is designed to decrease subjectivity when determining amounts of overlapping stimulation between implant electrodes.Approach. This visualization uses estimates of electric field strength to indicate spread of neural excitation due to each electrode. Unlike prior visualizations, this method explicitly defines regions of nerves receiving substantial stimulation from each electrode to help clinicians assess the presence of significant overlapping stimulation. A multi-reviewer study compared this and an existing technique on the consistency, efficiency, and optimality of plans generated from each method. Statistical significance was evaluated using the two-sided Wilcoxon rank sum test.Main results. The study showed statistically significant improvements in consistency (p < 10-12), efficiency (p < 10-15), and optimality (p < 10-5) when generating plans using the proposed method versus the existing method.Significance. This visualization addresses subjectivity in assessing overlapping stimulation between implant electrodes, which currently relies on reviewer estimates. The results of the evaluation indicate the provision of such objective information during programming sessions would likely benefit clinicians in making programming decisions.
Collapse
Affiliation(s)
- Erin L. Bratu
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, TN, USA
| | - Linsey W. Sunderhaus
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Katelyn A. Berg
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Robert T. Dwyer
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Robert F. Labadie
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - René H. Gifford
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
| | - Jack H. Noble
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, TN, USA
- Vanderbilt University Medical Center, Department of Hearing and Speech Sciences, Nashville, TN, USA
- Vanderbilt University Medical Center, Department of Otolaryngology – Head & Neck Surgery, Nashville, TN, USA
| |
Collapse
|
13
|
Cleary M, Bernstein JGW, Stakhovskaya OA, Noble J, Kolberg E, Jensen KK, Hoa M, Kim HJ, Goupell MJ. The Relationship Between Interaural Insertion-Depth Differences, Scalar Location, and Interaural Time-Difference Processing in Adult Bilateral Cochlear-Implant Listeners. Trends Hear 2022; 26:23312165221129165. [PMID: 36379607 PMCID: PMC9669699 DOI: 10.1177/23312165221129165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Sensitivity to interaural time differences (ITDs) in acoustic hearing involves comparison of interaurally frequency-matched inputs. Bilateral cochlear-implant arrays are, however, only approximately aligned in angular insertion depth and scalar location across the cochleae. Interaural place-of-stimulation mismatch therefore has the potential to impact binaural perception. ITD left-right discrimination thresholds were examined in 23 postlingually-deafened adult bilateral cochlear-implant listeners, using low-rate constant-amplitude pulse trains presented via direct stimulation to single electrodes in each ear. Angular insertion depth and scalar location measured from computed-tomography (CT) scans were used to quantify interaural mismatch, and their association with binaural performance was assessed. Number-matched electrodes displayed a median interaural insertion-depth mismatch of 18° and generally yielded best or near-best ITD discrimination thresholds. Two listeners whose discrimination thresholds did not show this pattern were confirmed via CT to have atypical array placement. Listeners with more number-matched electrode pairs located in the scala tympani displayed better thresholds than listeners with fewer such pairs. ITD tuning curves as a function of interaural electrode separation were broad; bandwidths at twice the threshold minimum averaged 10.5 electrodes (equivalent to 5.9 mm for a Cochlear-brand pre-curved array). Larger angular insertion-depth differences were associated with wider bandwidths. Wide ITD tuning curve bandwidths appear to be a product of both monopolar stimulation and angular insertion-depth mismatch. Cases of good ITD sensitivity with very wide bandwidths suggest that precise matching of insertion depth is not critical for discrimination thresholds. Further prioritizing scala tympani location at implantation should, however, benefit ITD sensitivity.
Collapse
Affiliation(s)
- Miranda Cleary
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Joshua G. W. Bernstein
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical
Center, Bethesda, MD, USA
| | - Olga A. Stakhovskaya
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Jack Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, USA,Department of Hearing and Speech Sciences, Vanderbilt University
Medical Center, Nashville, TN, USA,Department of Otolaryngology, Vanderbilt University Medical Center,
Nashville, TN, USA
| | - Elizabeth Kolberg
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA
| | - Kenneth K. Jensen
- National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical
Center, Bethesda, MD, USA
| | - Michael Hoa
- Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical
Center, Washington, DC, USA
| | - Hung Jeffrey Kim
- Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical
Center, Washington, DC, USA
| | - Matthew J. Goupell
- Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, USA,Matthew J. Goupell, Department of Hearing
and Speech Sciences, University of Maryland, College Park, MD 20742, USA.
| |
Collapse
|
14
|
Gifford RH, Sunderhaus LW, Holder JT, Berg KA, Dawant BM, Noble JH, Perkins E, Camarata S. Speech recognition as a function of the number of channels for pediatric cochlear implant recipients. JASA EXPRESS LETTERS 2022; 2:094403. [PMID: 36182337 PMCID: PMC9488908 DOI: 10.1121/10.0013428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 07/26/2022] [Indexed: 06/16/2023]
Abstract
This study investigated the number of channels required for asymptotic speech recognition for ten pediatric cochlear implant (CI) recipients with precurved electrode arrays. Programs with 4-22 active electrodes were used to assess word and sentence recognition in noise. Children demonstrated significant performance gains up to 12 electrodes for continuous interleaved sampling (CIS) and up to 22 channels with 16 maxima. These data are consistent with the latest adult CI studies demonstrating that modern CI recipients have access to more than 8 independent channels and that both adults and children exhibit performance gains up to 22 channels.
Collapse
Affiliation(s)
- René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA
| | - Linsey W Sunderhaus
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA
| | - Jourdan T Holder
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA
| | - Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA
| | - Benoit M Dawant
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA
| | - Jack H Noble
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee 37235, USA
| | - Elizabeth Perkins
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA , , , , , , ,
| | - Stephen Camarata
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA
| |
Collapse
|
15
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels for Mid-Scala electrode array recipients. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:67. [PMID: 35931512 PMCID: PMC9984239 DOI: 10.1121/10.0012163] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
This study investigated the number of channels needed for maximum speech understanding and sound quality in 15 adult cochlear implant (CI) recipients with Advanced Bionics (AB) Mid-Scala electrode arrays completely within scala tympani. In experiment I, CI programs used a continuous interleaved sampling (CIS)-based strategy and 4-16 active electrodes. In experiment II, CI programs used an n-of-m strategy featuring 16 active electrodes with either 8- or 12-maxima. Speech understanding and sound quality measures were assessed. For CIS programs, participants demonstrated performance gains using up to 4-10 electrodes on speech measures and sound quality ratings. For n-of-m programs, there was no significant effect of maxima, suggesting 8-maxima is sufficient for this sample's maximum performance and sound quality. These results are largely consistent with previous studies using straight electrode arrays [e.g., Fishman, Shannon, and Slattery (1997). J. Speech Lang. Hear. Res. 40, 1201-1215; Friesen, Shannon, Baskent, and Wang (2001). J. Acoust. Soc. Am. 110, 1150-1163; Shannon, Cruz, and Galvin (2011). Audiol. Neurotol. 16, 113-123; Berg, Noble, Dawant, Dwyer, Labadie, and Gifford (2020). J. Acoust. Soc. Am. 147, 3646-3656] and in contrast with recent studies looking at cochlear precurved electrode arrays [e.g., Croghan, Duran, and Smith (2017). J. Acoust. Soc. Am. 142, EL537-EL543; Berg, Noble, Dawant, Dwuer, Labadie, and Gifford (2019b). J. Acoust. Soc. Am. 145, 1556-1564], which found continuous improvements up to 16 independent channels. These findings suggest that Mid-Scala electrode array recipients demonstrate similar channel independence to straight electrode arrays rather than other manufacturer's precurved electrode arrays.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Advanced Bionics, 28515 Westinghouse Place, Valencia, California 91355, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
16
|
Leblans M, Sismono F, Vanpoucke F, van Dinther J, Lerut B, Kuhweide R, Offeciers E, Zarowski A. Novel Impedance Measures as Biomarker for Intracochlear Fibrosis. Hear Res 2022; 426:108563. [DOI: 10.1016/j.heares.2022.108563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 04/05/2022] [Accepted: 06/15/2022] [Indexed: 11/04/2022]
|
17
|
Avasarala VS, Jinka SK, Jeyakumar A. Complications of Cochleostomy Versus Round Window Surgical Approaches: A Systematic Review and Meta-Analysis. Cureus 2022; 14:e25451. [PMID: 35774686 PMCID: PMC9239322 DOI: 10.7759/cureus.25451] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/29/2022] [Indexed: 11/05/2022] Open
|
18
|
Mewes A, Burg S, Brademann G, Dambon JA, Hey M. Quality-assured training in the evaluation of cochlear implant electrode position: a prospective experimental study. BMC MEDICAL EDUCATION 2022; 22:386. [PMID: 35596162 PMCID: PMC9121556 DOI: 10.1186/s12909-022-03464-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 05/13/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND The objective of this study was to demonstrate the utility of an approach in training predoctoral medical students, to enable them to measure electrode-to-modiolus distances (EMDs) and insertion-depth angles (aDOIs) in cochlear implant (CI) imaging at the performance level of a single senior rater. METHODS This prospective experimental study was conducted on a clinical training dataset comprising patients undergoing cochlear implantation with a Nucleus® CI532 Slim Modiolar electrode (N = 20) or a CI512 Contour Advance electrode (N = 10). To assess the learning curves of a single medical student in measuring EMD and aDOI, interrater differences (senior-student) were compared with the intrarater differences of a single senior rater (test-retest). The interrater and intrarater range were both calculated as the distance between the 0.1th and 99.9th percentiles. A "deliberate practice" training approach was used to teach knowledge and skills, while correctives were applied to minimize faulty data-gathering and data synthesis. RESULTS Intrarater differences of the senior rater ranged from - 0.5 to 0.5 mm for EMD and - 14° to 16° for aDOI (respective medians: 0 mm and 0°). Use of the training approach led to interrater differences that matched this after the 4th (EMD) and 3rd (aDOI) feedback/measurement series had been provided to the student. CONCLUSIONS The training approach enabled the student to evaluate the CI electrode position at the performance level of a senior rater. This finding may offer a basis for ongoing clinical quality assurance for the assessment of CI electrode position.
Collapse
Affiliation(s)
- Alexander Mewes
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany.
| | - Sebastian Burg
- Christian-Albrechts-Universität (CAU) zu Kiel, Faculty of Medicine, Kiel, Germany
| | - Goetz Brademann
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany
| | - Jan Andreas Dambon
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany
| | - Matthias Hey
- Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Department of Otorhinolaryngology, Head and Neck Surgery, Kiel, Germany
| |
Collapse
|
19
|
Greisiger R, Heldahl MG, Myhrum M, Sørensen TM, Dammerud JJ, Rasmussen K, Korslund H, Bunne M, Jablonski GE. Effect of Proximity to the Modiolus for the Cochlear CI532 Slim Modiolar Electrode Array on Evoked Compound Action Potentials and Programming Levels. Audiol Neurootol 2022; 27:397-405. [PMID: 35504247 DOI: 10.1159/000524256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 03/09/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND The first surgeries with CI532 showed an effect of the proximity of the electrode to the modiolus on the Evoked Compound Action Potentials (ECAPs). OBJECTIVES Objectives of the study were to investigate the effect of the "pullback" procedure on intraoperative ECAP responses in three different electrode array positions and additionally to compare behavioral thresholds with the thresholds obtained in a group of patients using the standard insertion. The hypothesis of this study is that pullback will cause lower ECAPs and behavioral thresholds. PATIENTS The study included 40 patients, 20 in the pullback insertion group and 20 in the standard insertion group (without pullback). METHOD During insertion of the CI532 electrode array, ECAP was performed in three different positions for the pullback group: at initial insertion, at over-insertion, and after pullback. Insertion was monitored by fluoroscopy. In the standard group, ECAP was performed at the initial position, which is also the final position. ECAP thresholds (T-ECAPs) were compared within subjects at the initial and the final position in the pullback group and between groups in the final positions of the pullback and standard groups. Programming levels (C- and T-levels) were compared between the two groups 1 year after switch-on. RESULTS Intraoperative measurements pullback shows lower average T-ECAPs after pullback compared to thresholds in initial position. Comparison of intraoperative T-ECAPs at the final positions showed no statistically significant difference between the pullback group and the standard insertion group. Furthermore, 1 year after switch-on there was no statistically significant difference in C- and T-levels between the two groups. CONCLUSION The pullback maneuver of the CI532 electrode array after an over-insertion gave significantly lower T-ECAPs compared to the thresholds at the initial position. However, the between-groups analysis of pullback and standard insertion showed neither significantly different T-ECAPs nor different programming levels. Because T-ECAPs and programming levels vary considerably between subjects, large groups are required to detect differences between groups. Additionally, the effect pullback technique to preserving the residual hearing is not known yet.
Collapse
Affiliation(s)
- Ralf Greisiger
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway
| | | | - Marte Myhrum
- University of Oslo, Institute of Clinical Medicine, Oslo, Norway
| | | | | | - Kjell Rasmussen
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway
| | - Hilde Korslund
- Intervention Centre, Oslo University Hospital, Oslo, Norway
| | - Marie Bunne
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway
| | - Greg Eigner Jablonski
- Department of Otorhinolaryngology, Oslo University Hospital, Oslo, Norway.,University of Oslo, Institute of Clinical Medicine, Oslo, Norway
| |
Collapse
|
20
|
Sijgers L, Huber A, Tabibi S, Grosse J, Roosli C, Boyle P, Koka K, Dillier N, Pfiffner F, Dalbert A. Predicting Cochlear Implant Electrode Placement Using Monopolar, Three-Point and Four-Point Impedance Measurements. IEEE Trans Biomed Eng 2022; 69:2533-2544. [PMID: 35143392 DOI: 10.1109/tbme.2022.3150239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE This study aimed to investigate the relationship between cochlear implant (CI) electrode distances to the cochleas inner wall (the modiolus) and electrical impedance measurements made at the CIs electrode contacts. We introduced a protocol for three-point impedances in which we recorded bipolar impedances in response to monopolar stimulation at a neighboring electrode. We aimed to assess the usability of three-point impedances and two existing CI impedance measurement methods (monopolar and four-point impedances) for predicting electrode positioning during CI insertion. METHODS Impedances were recorded during stepwise CI electrode array insertions in cadaveric human temporal bones. The positioning of the electrodes with respect to the modiolus was assessed at each step using cone beam computed tomography. Linear mixed regression analysis was performed to assess the relationship between the impedances and electrode-modiolar distances. The experimental results were compared to clinical impedance data and to an existing lumped-element model of an implanted CI. RESULTS Three-point and four-point impedances strongly correlated with electrode-modiolar distance. In contrast, monopolar impedances were only minimally affected by changes in electrode positioning with respect to the modiolus. An overall model specificity of 62% was achieved when incorporating all impedance parameters. This specificity could be increased beyond 73% when prior expectations of electrode positioning were incorporated in the model. CONCLUSION Three-point and four-point impedances are promising measures to predict electrode-modiolar distance in real-time during CI insertion. SIGNIFICANCE This work shows how electrical impedance measurements can be used to predict the CIs electrode positioning in a biologically realistic model.
Collapse
|
21
|
Lei IM, Jiang C, Lei CL, de Rijk SR, Tam YC, Swords C, Sutcliffe MPF, Malliaras GG, Bance M, Huang YYS. 3D printed biomimetic cochleae and machine learning co-modelling provides clinical informatics for cochlear implant patients. Nat Commun 2021; 12:6260. [PMID: 34716306 PMCID: PMC8556326 DOI: 10.1038/s41467-021-26491-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 10/06/2021] [Indexed: 02/07/2023] Open
Abstract
Cochlear implants restore hearing in patients with severe to profound deafness by delivering electrical stimuli inside the cochlea. Understanding stimulus current spread, and how it correlates to patient-dependent factors, is hampered by the poor accessibility of the inner ear and by the lack of clinically-relevant in vitro, in vivo or in silico models. Here, we present 3D printing-neural network co-modelling for interpreting electric field imaging profiles of cochlear implant patients. With tuneable electro-anatomy, the 3D printed cochleae can replicate clinical scenarios of electric field imaging profiles at the off-stimuli positions. The co-modelling framework demonstrated autonomous and robust predictions of patient profiles or cochlear geometry, unfolded the electro-anatomical factors causing current spread, assisted on-demand printing for implant testing, and inferred patients' in vivo cochlear tissue resistivity (estimated mean = 6.6 kΩcm). We anticipate our framework will facilitate physical modelling and digital twin innovations for neuromodulation implants.
Collapse
Affiliation(s)
- Iek Man Lei
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom.,The Nanoscience Centre, University of Cambridge, Cambridge, United Kingdom
| | - Chen Jiang
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom.,Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom.,Department of Electronic Engineering, Tsinghua University, Beijing, 100084, China
| | - Chon Lok Lei
- Institute of Translational Medicine, Faculty of Health Sciences, University of Macau, Taipa, Macau.,Department of Computer Science, University of Oxford, Oxford, United Kingdom
| | - Simone Rosalie de Rijk
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom
| | - Yu Chuen Tam
- Emmeline Centre for Hearing Implants, Addenbrookes Hospital, Cambridge, United Kingdom
| | - Chloe Swords
- Department of Physiology, Development and Neurosciences, Cambridge, United Kingdom
| | | | - George G Malliaras
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Manohar Bance
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom.
| | - Yan Yan Shery Huang
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom. .,The Nanoscience Centre, University of Cambridge, Cambridge, United Kingdom.
| |
Collapse
|
22
|
Effects of in vivo repositioning of slim modiolar electrodes on electrical thresholds and speech perception. Sci Rep 2021; 11:15135. [PMID: 34302030 PMCID: PMC8302625 DOI: 10.1038/s41598-021-94668-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Accepted: 07/13/2021] [Indexed: 02/07/2023] Open
Abstract
The slim modiolar electrode has been reported to ensure better modiolar proximity than previous conventional perimodiolar electrodes and consistently high scala tympani localization. Nonetheless, variability in modiolar proximity exists even among slim modiolar electrodes, still leaving room for further improvement of modiolar proximity, which may positively affect functional outcomes. Given this, the pull-back maneuver was reported to increase the modiolar proximity of slim modiolar electrodes in a cadaveric study, but in vivo repositioning effects remain to be established. Here we identified that the pull-back maneuver led to better modiolar proximity than conventional insertion while maintaining a similar angular insertion depth. Notably, the reduced electrode-modiolus distance from the pull-back maneuver was associated with significantly lower impedances across electrodes postoperatively as well as reduced intraoperative electrophysiological thresholds than conventional insertion. Among adult cochlear implant recipients, this maneuver resulted in significantly better sentence recognition scores at three months postoperatively when compared to those with a conventional insertion; however, this benefit was not observed at later intervals. Collectively, slim modiolar electrodes with the pull-back maneuver further enhance the modiolar proximity, possibly leading to better open-set sentence recognition, at least in the early postoperative stage.
Collapse
|
23
|
Schvartz-Leyzac KC, Zwolan TA, Pfingst BE. Using the electrically-evoked compound action potential (ECAP) interphase gap effect to select electrode stimulation sites in cochlear implant users. Hear Res 2021; 406:108257. [PMID: 34020316 DOI: 10.1016/j.heares.2021.108257] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 03/25/2021] [Accepted: 04/19/2021] [Indexed: 10/21/2022]
Abstract
Studies in cochlear implanted animals show that the IPG Effect for ECAP growth functions (i.e., the magnitude of the change in ECAP amplitude growth function (AGF) slope or peak amplitude when the interphase gap (IPG) is increased) can be used to estimate the densities of spiral ganglion neurons (SGNs) near the electrode stimulation and recording sites. In humans, the same ECAP IPG Effect measures correlate with speech recognition performance. The present study examined the efficacy of selecting electrode sites for stimulation based on the IPG Effect, in order to improve performance of CI users on speech recognition tasks. We measured the ECAP IPG Effect for peak amplitude in adult (>18 years old) CI users (N= 18 ears), and created experimental programs to stimulate electrodes with either the highest or lowest ECAP IPG Effect for peak amplitude. Subjects also listened to a program without any electrodes deactivated. In a subset of subject ears (11/18), we compared performance differences between the experimental programs to post-operative computerized tomography (CT) scans to examine underlying factors that might contribute to the efficacy of an electrode site-selection approach. For sentences-in-noise, average performance was better when subjects listened to the experimental program that stimulated electrodes with the highest rather than the lowest IPG Effect for ECAP peak amplitude. A similar pattern was noted for transmission and perception of consonant place cues in a consonant recognition task. However, on average, performance when listening to a program with higher IPG Effect values was equal to that when listening with all electrodes activated. Results also suggest that scalar location (scala tympani or vestibuli) should be considered when using an ECAP-based electrode site-selection procedure to optimize CI performance.
Collapse
Affiliation(s)
- Kara C Schvartz-Leyzac
- Kresge Hearing Research Institute, Department of Otolaryngology, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI 48109-5616, United States; Hearing Rehabilitation Center, Department of Otolaryngology, Michigan Medicine, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI 48108, United States.
| | - Teresa A Zwolan
- Hearing Rehabilitation Center, Department of Otolaryngology, Michigan Medicine, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI 48108, United States
| | - Bryan E Pfingst
- Kresge Hearing Research Institute, Department of Otolaryngology, Michigan Medicine, 1150 West Medical Center Drive, Ann Arbor, MI 48109-5616, United States
| |
Collapse
|
24
|
Ludwig S, Riemann N, Hans S, Christov F, Ludwig JM, Saxe J, Arweiler-Harbeck D. Evaluation of hearing preservation in adults with a slim perimodiolar electrode. Eur Arch Otorhinolaryngol 2021; 279:1233-1242. [PMID: 33830367 PMCID: PMC8897335 DOI: 10.1007/s00405-021-06755-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 03/12/2021] [Indexed: 12/01/2022]
Abstract
PURPOSE Numerous endeavors have been undertaken to preserve hearing in cochlear implant (CI) patients. Particularly, optimization of electrode array design aims at preservation of residual hearing (RH). This study examines whether a slim perimodiolar (PM) electrode array could bear the capability to preserve hearing. METHODS A total of 47 patients underwent cochlear implantation receiving the PM electrode. (i) Patients with pure tone audiogram (PTA) thresholds better than 85 dB and/or hearing loss for Freiburg speech test numbers less than 60 dB and more than 50% maximum monosyllabic understanding were assigned to the RH group (n = 17), while all others belonged to the noRH group (n = 30). (ii) Another group implanted with a slim straight, lateral wall (LW) electrode was recruited for comparison. RESULTS We compared 17 RH-30 noRH patients all receiving the PM electrode. RH in PM recipients decreased faster than in LW recipients. No significant differences were observed between both (RH v/s noRH) groups in NRT thresholds, Freiburg speech test and A§E® phonemes. Analogous satisfaction levels were indicated through the questionnaires in terms of sound quality, hearing in silence, noise and directional hearing in both groups. CONCLUSIONS The results suggest that hearing preservation is influenced not only by electrode shape but various factors. This study opens an avenue for further investigations to elucidate and enumerate the causes for progressive hearing loss.
Collapse
Affiliation(s)
- Sonja Ludwig
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty Mannheim, University Hospital Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, Mannheim, Germany.
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany.
| | - Niklas Riemann
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Stefan Hans
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Florian Christov
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
- ENT Practice Cologne-Bonn, Wesseling, Germany
| | - Johannes Maximilian Ludwig
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Judith Saxe
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Diana Arweiler-Harbeck
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| |
Collapse
|
25
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels for an array with large inter-electrode distances. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:2752. [PMID: 33940865 PMCID: PMC8062138 DOI: 10.1121/10.0004244] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 03/22/2021] [Accepted: 03/22/2021] [Indexed: 05/28/2023]
Abstract
This study investigated the number of channels available to cochlear implant (CI) recipients for maximum speech understanding and sound quality for lateral wall electrode arrays-which result in large electrode-to-modiolus distances-featuring the greatest inter-electrode distances (2.1-2.4 mm), the longest active lengths (23.1-26.4 mm), and the fewest number of electrodes commercially available. Participants included ten post-lingually deafened adult CI recipients with MED-EL electrode arrays (FLEX28 and STANDARD) entirely within scala tympani. Electrode placement and scalar location were determined using computerized tomography. The number of channels was varied from 4 to 12 with equal spatial distribution across the array. A continuous interleaved sampling-based strategy was used. Speech recognition, sound quality ratings, and a closed-set vowel recognition task were measured acutely for each electrode condition. Participants did not demonstrate statistically significant differences beyond eight channels at the group level for almost all measures. However, several listeners showed considerable improvements from 8 to 12 channels for speech and sound quality measures. These results suggest that channel interaction caused by the greater electrode-to-modiolus distances of straight electrode arrays could be partially compensated for by a large inter-electrode distance or spacing.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
26
|
Jwair S, Prins A, Wegner I, Stokroos RJ, Versnel H, Thomeer HGXM. Scalar Translocation Comparison Between Lateral Wall and Perimodiolar Cochlear Implant Arrays - A Meta-Analysis. Laryngoscope 2020; 131:1358-1368. [PMID: 33159469 PMCID: PMC8246990 DOI: 10.1002/lary.29224] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 12/15/2022]
Abstract
Objectives/Hypothesis Two types of electrode arrays for cochlear implants (CIs) are distinguished: lateral wall and perimodiolar. Scalar translocation of the array can lead to intracochlear trauma by penetrating from the scala tympani into the scala vestibuli or scala media, potentially negatively affecting hearing performance of CI users. This systematic review compares the lateral wall and perimodiolar arrays with respect to scalar translocation. Study Design Systematic review. Methods PubMed, Embase, and Cochrane databases were reviewed for studies published within the last 11 years. No other limitations were set. All studies with original data that evaluated the occurrence of scalar translocation or tip fold‐over (TF) with postoperative computed tomography (CT) following primary cochlear implantation in bilateral sensorineuronal hearing loss patients were considered to be eligible. Data were extracted independently by two reviewers. Results We included 33 studies, of which none were randomized controlled trials. Meta‐analysis of five cohort studies comparing scalar translocation between lateral wall and perimodiolar arrays showed that lateral wall arrays have significantly lower translocation rates (7% vs. 43%; pooled odds ratio = 0.12). Translocation was negatively associated with speech perception scores (weighted mean 41% vs. 55%). Tip fold‐over of the array was more frequent with perimodiolar arrays (X2 = 6.8, P < .01). Conclusions Scalar translocation and tip fold‐overs occurred more frequently with perimodiolar arrays than with lateral wall arrays. In addition, translocation of the array negatively affects hearing with the cochlear implant. Therefore, if one aims to minimize clinically relevant intracochlear trauma, lateral wall arrays would be the preferred option for cochlear implantation. Laryngoscope, 131:1358–1368, 2021
Collapse
Affiliation(s)
- Saad Jwair
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Adrianus Prins
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Inge Wegner
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Robert J Stokroos
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Huib Versnel
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Hans G X M Thomeer
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
27
|
Aebischer P, Meyer S, Caversaccio M, Wimmer W. Intraoperative Impedance-Based Estimation of Cochlear Implant Electrode Array Insertion Depth. IEEE Trans Biomed Eng 2020; 68:545-555. [PMID: 32746052 DOI: 10.1109/tbme.2020.3006934] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Cochlear implant impedances are influenced by the intracochlear position of the electrodes. Herein, we present an intuitive approach to calculate tissue resistances from transimpedance recordings, ultimately enabling to estimate the insertion depth of cochlear implant electrodes. METHODS Electrode positions were measured in computed-tomography images of 20 subjects implanted with the same lateral wall cochlear implant model. The tissue resistances were estimated from intraoperative telemetry data using bivariate spline extrapolation from the transimpedance recordings. Using a phenomenological model, the electrode insertion depths were estimated. RESULTS The proposed method enabled the linear insertion depth of all electrodes to be estimated with an average error of 0.76 ± 0.53 mm. CONCLUSION Intraoperative telemetry recordings correlate with the linear and angular depth of electrode insertion, enabling estimations with an accuracy that can be useful for clinical applications. SIGNIFICANCE The proposed method can be used to objectively assess surgical outcomes during and after cochlear implantation based on non-invasive and readily available telemetry recordings.
Collapse
|
28
|
Evaluation of artifacts of cochlear implant electrodes in cone beam computed tomography. Eur Arch Otorhinolaryngol 2020; 278:1381-1386. [PMID: 32671538 PMCID: PMC8057993 DOI: 10.1007/s00405-020-06198-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 07/07/2020] [Indexed: 12/27/2022]
Abstract
Purpose Cone Beam Computed Tomography (CBCT) offers a valid alternative to conventional Computed Tomography (CT). A possible radiation dose reduction with the use of CBCT in postoperative imaging of CIs is of great importance. Whether the visualization of Cochlear Implant (CI) electrodes in CBCT correlates with the radiation dose applied was investigated in this study. Methods We compared the visualization quality of Contour Advance CIs to Straight CIs from Cochlear using CBCT with varying tube parameters on whole-head specimen. Results The internal diameter of the cochlea decreases from base to apex, resulting in a significantly different intracochlear positioning of the two tested CI models. While electrodes of the Contour Advance series are located close to the modiolus, thus closer to the spiral ganglion neurons, those of the Straight series are located further away. The artifact portion of the electrode amounts to 50–70% of the radiological diameter of the electrode. An increase in artifact portion from the base (electrode #1 approx. 50%) to the apex (electrode #20 approx. 70%) of the cochlea was observed. The visualization of electrodes in the medial and apical part of the cochlea is limited due to artifact overlapping. There was no correlation between the artifact size and the applied radiation dose. Conclusion The results indicate that a reduction of the radiation dose by up to 45% of the currently applied radiation dose of standard protocols would be possible. Investigations of the effects on subjective image quality still need to be performed.
Collapse
|
29
|
Abstract
BACKGROUND The perimodiolar CI532 Slim Modiolar electrode has been designed to bring the electrode contacts close to auditory nerve while reducing cochlear trauma during its insertion. It is currently unknown to what extent the electrode position and electrophysiological outcomes of the Slim Modiolar electrode differ from other perimodiolar electrodes. OBJECTIVES The objective was to compare the electrode position and electrophysiological outcomes between the CI532 Slim Modiolar and CI512 Contour Advance electrode. METHOD Forty-six adult patients received a Slim Modiolar or Contour Advance electrode. Electrode types were compared using intraoperative electrode impedances, evoked compound action potential (ECAP) and stapedius reflex thresholds, as well as position parameters from postoperative computed tomography or digital volume tomography images (medial-lateral position, electrode-to-modiolus distance, insertion angle). RESULTS The medial-lateral position indicates a closer modiolar placement of the Slim Modiolar compared with the Contour Advance. Individual electrode contact measurements, however, showed significantly larger electrode-to-modiolus distances and higher ECAP thresholds for the Slim Modiolar in the basal region. On contacts E20-22 the Slim Modiolar is slightly closer to the modiolus compared with the Contour Advance, but this did not result in lower ECAP thresholds. CONCLUSIONS Perimodiolar electrodes can vary in their intracochlear position, leading to divergent electrophysiological outcomes. To detect these differences, investigations must be done for each electrode contact rather than using a global factor for the whole electrode array. While the electrode dislocation rate is lower with the Slim Modiolar than with the Contour Advance, electrode-to-modiolus proximity is smaller and ECAP thresholds are lower with the Contour Advance in the basal cochlear region.
Collapse
|
30
|
Velandia S, Martinez D, Goncalves S, Pena S, Bas E, Ein L, Prentiss S, Telischi F, Angeli S, Dinh CT. Effect of age, electrode array, and time on cochlear implant impedances. Cochlear Implants Int 2020; 21:344-352. [PMID: 32640889 DOI: 10.1080/14670100.2020.1788859] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Objectives: To determine the impact of age, electrode array, and time on impedance patterns in cochlear implant (CI) patients. Methods: A retrospective case review was performed on 98 patients implanted with the CI24RE perimodiolar (PM) and CI422 lateral wall (LW) arrays between 2010 and 2014 to assess impedances at the 1 week and 3-6 month visit after initial stimulation (IS). Results: With respect to age, impedances were higher in young patients compared to older patients in the middle and apical turns. With time, there were significant reductions in impedances across most electrodes. Electrode array type also had a significant impact on impedance measurements with PM and LW arrays having higher impedances in the basal turn and apical turns, respectively. Furthermore, PM arrays demonstrated significantly lower impedances in the middle and apical turn with time, when compared to LW arrays. Conclusions: Age, electrode array, and time can independently affect CI impedances. Moreover, we show that PM arrays may be advantageous to LW arrays, due to demonstrated lower impedances in the middle and apical turns long term. Understanding the impact of impedance on speech discrimination and determining the intracochlear processes that contribute to differences in impedance are future research directions.
Collapse
Affiliation(s)
- Sandra Velandia
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Diane Martinez
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Stefania Goncalves
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Stefanie Pena
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Esperanza Bas
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Liliana Ein
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Sandra Prentiss
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Fred Telischi
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Simon Angeli
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Christine T Dinh
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
31
|
Abstract
OBJECTIVE Characterize differences in adult cochlear implant outcomes and programming parameters for a straight (CI422/522) and a precurved (CI532) electrode array. SETTING Cochlear implant (CI) program at a tertiary otologic center. PATIENTS Fifty-eight adults were included in the study; 29 were implanted with CI422 or CI522 and 29 were implanted with CI532. Each CI532 recipient was matched to a CI422/522 recipient in terms of age and preoperative hearing thresholds for comparison purposes. MAIN OUTCOME MEASURES Consonant-Nucleus-Consonant (CNC) words, AzBio sentences, residual audiometric thresholds, and Speech Spatial Qualities (SSQ) questionnaire collected 6 months postoperatively were used to characterize outcomes. Pulse duration, maxima, impedances, and overall charge measurements were used to characterize programming parameters. RESULTS Postoperative unaided low frequency pure-tone average (LFPTA) was significantly better for the CI532 group. CNC scores were significantly better for the CI532 group. Impedances and pulse duration were significantly lower for the CI532 group, but there was no difference in overall charge between the groups. CONCLUSION The CI532 group showed either similar or statistically superior results on all measures when compared with the CI422/522 suggesting that the CI532 electrode may be an advantageous substitute for the CI522.
Collapse
|
32
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition with cochlear implants as a function of the number of channels: Effects of electrode placement. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 147:3646. [PMID: 32486813 PMCID: PMC7255811 DOI: 10.1121/10.0001316] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 05/08/2020] [Accepted: 05/08/2020] [Indexed: 05/28/2023]
Abstract
This study investigated the effects of cochlear implant (CI) electrode array type and scalar location on the number of channels available to CI recipients for maximum speech understanding and sound quality. Eighteen post-lingually deafened adult CI recipients participated, including 11 recipients with straight electrode arrays entirely in scala tympani and 7 recipients with translocated precurved electrode arrays. Computerized tomography was used to determine electrode placement and scalar location. In each condition, the number of channels varied from 4 to 22 with equal spatial distribution across the array. Speech recognition (monosyllables, sentences in quiet and in noise), subjective speech sound quality, and closed-set auditory tasks (vowels, consonants, and spectral modulation detection) were measured acutely. Recipients with well-placed straight electrode arrays and translocated precurved electrode arrays performed similarly, demonstrating asymptotic speech recognition scores with 8-10 channels, consistent with the classic literature. This finding contrasts with recent work [Berg, Noble, Dawant, Dwyer, Labadie, and Gifford. (2019). J. Acoust. Soc. Am. 145, 1556-1564] that found precurved electrode arrays well-placed in scala tympani demonstrate continuous performance gains beyond 8-10 channels. Given these results, straight and translocated precurved electrode arrays are theorized to have less channel independence secondary to their placement farther away from neural targets.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
33
|
Khurayzi T, Dhanasingh A, Almuhawas F, Alsanosi A. Shape of the Cochlear Basal Turn: An Indicator for an Optimal Electrode-to-Modiolus Proximity With Precurved Electrode Type. EAR, NOSE & THROAT JOURNAL 2020; 100:38-43. [PMID: 32330070 DOI: 10.1177/0145561320920965] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
OBJECTIVE The objective of this study was to determine the shape of cochlear basal turn through basic cochlear parameters measurement. The secondary aim was to overlay an image of the precurved electrode array on top of the three-dimensional (3D) image of the cochlea to determine which shape of the cochlear basal turn gives optimal electrode-to-modiolus proximity. MATERIALS AND METHODS Computed tomography (CT) preoperative image-data sets of 117 ears were made available for the measurements of cochlear parameters retrospectively. Three-dimensional slicer was used in the visualization and measurement of cochlear parameters from both 3D and 2D (2-dimensional) images of the inner ear. Cochlear parameters including basal turn diameter (A), width of the basal turn (B), and cochlear height (H) were measured from the appropriate planes. B/A ratio was made to investigate which ratios correspond to round and elliptical shape of the cochlear basal turn. RESULTS The cochlear size as measured by A value ranged between 7.4 mm and 10 mm. The B value and the cochlear height (H) showed a weak positive linear relation with A value. The ratio between the B and A values anything above or below 0.75 could be an indicator for a more round- or elliptical shaped cochlear basal turn, respectively. One sized/shaped commercially available precurved electrode array would not offer a tight electrode-to-modiolus in the cochlea that has an elliptical shaped basal turn as identified by the B/A ratio of <0.75. CONCLUSION Accurate measurement of cochlear parameters adds value to the overall understanding of the cochlear geometry before a cochlear implantation procedure. The shape of cochlear basal turn could have clinical implications when comes to electrode-to-modiolus proximity.
Collapse
Affiliation(s)
- Tawfiq Khurayzi
- King Abdullah Ear Specialist Center, 37850King Saud University, Riyadh, Saudi Arabia
| | | | - Fida Almuhawas
- King Abdullah Ear Specialist Center, 37850King Saud University, Riyadh, Saudi Arabia
| | - Abdurrahman Alsanosi
- King Abdullah Ear Specialist Center, 37850King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
34
|
Videhult Pierre P, Eklöf M, Smeds H, Asp F. Cochlear Implantation with the CI512 and CI532 Precurved Electrode Arrays: One-Year Speech Recognition and Intraoperative Thresholds of Electrically Evoked Compound Action Potentials. Audiol Neurootol 2019; 24:299-308. [PMID: 31846976 DOI: 10.1159/000504592] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Accepted: 11/05/2019] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION Precurved cochlear implant (CI) electrode arrays were developed in an attempt to improve the auditory outcome of cochlear implantation, which varies greatly. The recent CI532 (Cochlear Corp., Sydney, Australia) may offer further advantages as its electrode array is thinner than previous precurved CI electrode arrays. The aims here were to investigate 1-year postoperative speech recognition, intraoperative electrically evoked compound action potentials (ECAPs), and their possible relation in patients implanted with a CI532 or its predecessor CI512. METHODS A retrospective analysis of data from 63 patients subjected to cochlear implantation at the Karolinska University Hospital, Sweden, was performed. Speech recognition of the implanted ear was evaluated using phonemically balanced monosyllabic Swedish words at 65 dB SPL. ECAPs were evaluated using the intraoperative ECAP threshold across ≥8 electrodes generated by the automated neural response telemetry of the CI. RESULTS The median aided speech recognition score (SRS) 1 year after implantation was 52% (quartile 1 = 40%, quartile 3 = 60%, n = 63) and did not differ statistically significantly between patients with CI512 (n = 38) and CI532 (n = 25). The mean ECAP threshold was 188 CL (current level; SD = 15 CL, n = 54) intraoperatively and did not differ statistically significantly between patients with CI512 (n = 32) and CI532 (n = 22), but the threshold for each electrode varied more between patients with a CI512 (p < 0.0001). A higher mean ECAP threshold was associated with a worse SRS (Spearman's ρ = -0.46, p = 0.0004, n = 54). The association remained among those with a CI512 (Spearman's ρ = -0.62, p = 0.0001, n = 32) when stratified by CI electrode array. CONCLUSION No statistically significant difference in speech recognition 1 year after cochlear implantation or in mean threshold of ECAP intraoperatively was found between patients with a CI512 and the more recent, slim CI532, but the ECAP thresholds varied more between those with a CI512. A statistically significant association between SRS and mean ECAP threshold was found, but stratified analysis suggests that the association may be true only for patients with a CI512.
Collapse
Affiliation(s)
- Pernilla Videhult Pierre
- Division of Audiology, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden,
| | - Martin Eklöf
- Division of Ear, Nose and Throat, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.,Department of Otorhinolaryngology, Karolinska University Hospital, Stockholm, Sweden
| | - Henrik Smeds
- Division of Ear, Nose and Throat, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.,Department of Otorhinolaryngology, Karolinska University Hospital, Stockholm, Sweden
| | - Filip Asp
- Division of Ear, Nose and Throat, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.,Department of Otorhinolaryngology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
35
|
The Insertion Results of a Mid-scala Electrode Assessed by MRI and CBCT Image Fusion. Otol Neurotol 2019; 39:e1019-e1025. [PMID: 30444847 DOI: 10.1097/mao.0000000000002045] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To investigate the results of clinical surgical insertions with a Mid-scala array (HIFocus Mid-Scala Electrode, HFms). STUDY DESIGN Consecutive retrospective case study. SETTINGS Tertiary referral center. PATIENTS Analyses of imaging data of 26 consecutive patients (31 insertions) implanted with the HFms. INTERVENTION (S) The evaluation of insertion trauma evoked by a previously validated image fusion technique. Electrode reconstructions from postoperative cone-beam computed tomography (CBCT) were overlaid onto preoperative magnetic resonance imaging (MRI) scans to create artifact-free images. MAIN OUTCOME MEASURES The electrode position was quantified in relation to the basilar membrane. Trauma scaling adopted from Eshraghi was used for evaluating insertion trauma. The results of the visual assessment of the postoperative CBCT were compared to those obtained with the fusion technique. RESULTS Three insertions had to be excluded due to incompatibility of the imaging data with the fusion software. We found consistent peri- to mid-modiolar placement of the HFms with a mean insertion depth angle of 376°. According to the medical records, a visual examination of the postoperative CBCT indicated that there had been no scala dislocations but when assessed by the image fusion technique, five scala dislocations (17.8%) were found. Additionally, one tip fold-over was detected in the postoperative CBCT even though this was not evident in any intraoperative measurements. CONCLUSION HFms showed atraumatic surgical insertion results with consistent mid-modiolar placement. Image fusion enhances the accuracy of the insertion trauma assessment. Routine postoperative imaging is recommended for identifying tip fold-over as well as for quality control and documentation.
Collapse
|
36
|
Berg K, Noble J, Dawant B, Dwyer R, Labadie R, Richards V, Gifford R. Musical Sound Quality as a Function of the Number of Channels in Modern Cochlear Implant Recipients. Front Neurosci 2019; 13:999. [PMID: 31607846 PMCID: PMC6769043 DOI: 10.3389/fnins.2019.00999] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 09/03/2019] [Indexed: 11/18/2022] Open
Abstract
Objectives This study examined musical sound quality (SQ) in adult cochlear implant (CI) recipients. The study goals were to determine: the number of channels needed for high levels of musical SQ overall and by musical genre; the impact of device and patient factors on musical SQ ratings; and the relationship between musical SQ, speech recognition, and speech SQ to relate these findings to measures frequently used in clinical protocols. Methods Twenty-one post-lingually deafened adult CI recipients participated in this study. Electrode placement, including scalar location, average electrode-to-modiolus distance (M¯), and angular insertion depth were determined by CT imaging using validated CI position analysis algorithms (e.g., Noble et al., 2013; Zhao et al., 2018, 2019). CI programs were created using 4–22 electrodes with equal spatial distribution of active electrodes across the array. Speech recognition, speech SQ, music perception via a frequency discrimination task, and musical SQ were acutely assessed for all electrode conditions. Musical SQ was assessed using pre-selected musical excerpts from a variety of musical genres. Results CI recipients demonstrated continuous improvement in qualitative judgments of musical SQ with up to 10 active electrodes. Participants with straight electrodes placed in scala tympani (ST) and pre-curved electrodes with higher M¯ variance reported higher levels of musical SQ; however, this relationship is believed to be driven by levels of musical experience as well as the potential for preoperative bias in device selection. Participants reported significant increases in musical SQ beyond four channels for all musical genres examined in the current study except for Hip Hop/Rap. After musical experience outliers were removed, there was no relationship between musical experience or frequency discrimination ability and musical SQ ratings. There was a weak, but significant correlation between qualitative ratings for speech stimuli presented in quiet and in noise and musical SQ. Conclusion Modern CI recipients may need more channels for musical SQ than even required for asymptotic speech recognition or speech SQ. These findings may be used to provide clinical guidance for personalized expectations management of music appreciation depending on individual device and patient factors.
Collapse
Affiliation(s)
- Katelyn Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Jack Noble
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, United States.,Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, United States.,Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Benoit Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, United States.,Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Robert Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Robert Labadie
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, United States.,Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, United States
| | - Virginia Richards
- Department of Cognitive Science, University of California, Irvine, Irvine, CA, United States
| | - René Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, United States.,Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, United States
| |
Collapse
|
37
|
Nassiri AM, Yawn RJ, Gifford RH, Haynes DS, Roberts JB, Gilbane MS, Murfee J, Bennett ML. Intraoperative Electrically Evoked Compound Action Potential (ECAP) Measurements in Traditional and Hearing Preservation Cochlear Implantation. J Am Acad Audiol 2019; 30:918-926. [PMID: 31274070 DOI: 10.3766/jaaa.18052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND In current practice, the status of residual low-frequency acoustic hearing in hearing preservation cochlear implantation (CI) is unknown until activation two to three weeks postoperatively. The intraoperatively measured electrically evoked compound action potential (ECAP), a synchronous response from electrically stimulated auditory nerve fibers, is one of the first markers of auditory nerve function after cochlear implant surgery and such may provide information regarding the status of residual low-frequency acoustic hearing. PURPOSE This study aimed to evaluate the relationship between intraoperative ECAP at the time of CI and presence of preoperative and postoperative low-frequency acoustic hearing. RESEARCH DESIGN A retrospective case review. STUDY SAMPLE Two hundred seventeen adult ears receiving CI (42 Advanced Bionics, 82 Cochlear, and 93 MED-EL implants). INTERVENTIONS Intraoperative ECAP and CI. DATA COLLECTION AND ANALYSIS ECAP measurements were obtained intraoperatively, whereas residual hearing data were obtained from postoperative CI activation audiogram. A linear mixed model test revealed no interaction effects for the following variables: manufacturer, electrode location (basal, middle, and apical), preoperative low-frequency pure-tone average (LFPTA), and postoperative LFPTA. The postoperative residual low-frequency hearing status was defined as preservation of unaided air conduction thresholds ≤90 dB at 250 Hz. Electrode location and hearing preservation data were analyzed individually for both the ECAP threshold and ECAP maximum amplitude using multiple t-tests, without assuming a consistent standard deviation between the groups, and with alpha correction. RESULTS The maximum amplitude, in microvolts, was significantly higher throughout apical and middle regions of the cochlea in patients who had preserved low-frequency acoustic hearing as compared with those who did not have preserved hearing (p = 0.0001 and p = 0.0088, respectively). ECAP threshold, in microamperes, was significantly lower throughout the apical region of the cochlea in patients with preserved low-frequency acoustic hearing as compared with those without preserved hearing (p = 0.0099). Basal electrode maximum amplitudes and middle and basal electrode thresholds were not significantly correlated with postoperative low-frequency hearing. CONCLUSIONS Apical and middle electrode maximum amplitudes and apical electrode thresholds detected through intraoperative ECAP measurements are significantly correlated with preservation of low-frequency acoustic hearing. This association may represent a potential immediate feedback mechanism for postoperative outcomes that can be applied to all CIs.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Jack Murfee
- Vanderbilt University Medical Center, Nashville, TN
| | | |
Collapse
|
38
|
Chakravorti S, Noble JH, Gifford RH, Dawant BM, O’Connell B, Wang J, Labadie RF. Further Evidence of the Relationship Between Cochlear Implant Electrode Positioning and Hearing Outcomes. Otol Neurotol 2019; 40:617-624. [PMID: 31083083 PMCID: PMC6788798 DOI: 10.1097/mao.0000000000002204] [Citation(s) in RCA: 88] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Postoperative imaging studies by numerous groups have revealed that final cochlear implant (CI) electrode position impacts audiological outcomes with scalar location consistently shown to be a significant factor. Modiolar proximity has been less extensively studied, and findings regarding the effect of insertion depth have been inconsistent. METHODS Using previously developed automated algorithms, we determined CI electrode position in an Institutional Review Board-approved database of 220 CI ears. Generalized linear models (GLM) were used to analyze the relationship between audiological outcomes and factors including age, duration of CI use, device type, and electrode position. RESULTS For precurved arrays, GLM revealed that scalar position, modiolar proximity, base insertion depth, and sex were significant factors for Consonant-Nucleus-Consonant (CNC) words (R = 0.43, p < 0.001, n = 92 arrays), while scalar position, modiolar proximity, age, and postlingual onset of deafness were significant for Bamford-Kawal-Bench Sentences in Noise (BKB-SIN) (R = 0.51, p < 0.001, n = 85) scores. Other factors were not significant in the final model after controlling for these variables. For straight arrays, we found the insertion depth, postlingual deafness, and length of CI use to be highly significant (R = 0.47, p < 0.001) factors for CNC words (91 arrays), while for BKB-SIN scores the most significant (R = 0.47, p < 0.001) factors were insertion depth, younger age, and postlingual deafness (89 arrays). CONCLUSION Our results confirm the significance of electrode positioning in audiological outcomes. The most significant positional predictors of outcome for precurved arrays were full scala tympani (ST) insertion and the modiolar distance, while for the lateral wall arrays the depth of insertion was the most significant factor.
Collapse
Affiliation(s)
- Srijata Chakravorti
- Department of Electrical Engineering and Computer Science, Vanderbilt University
| | - Jack H. Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University
- Vanderbilt Bill Wilkerson Center, Department of Hearing and Speech Sciences, Vanderbilt University Medical Center
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center
| | - René H. Gifford
- Vanderbilt Bill Wilkerson Center, Department of Hearing and Speech Sciences, Vanderbilt University Medical Center
| | - Benoit M. Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University
| | - Brendan O’Connell
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center
| | - Jianing Wang
- Department of Electrical Engineering and Computer Science, Vanderbilt University
| | - Robert F. Labadie
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center
| |
Collapse
|
39
|
Gomez Serrano M, Patel S, Harris R, Selvadurai D. Initial surgical and clinical experience with the Nucleus CI532 slim modiolar electrode in the UK. Cochlear Implants Int 2019; 20:207-216. [PMID: 30947632 DOI: 10.1080/14670100.2019.1597461] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
OBJECTIVE The goal of this work is to describe the first experience in the UK with the slim pre-curved perimodiolar electrode Nucleus CI532 in a continuous series of patients in terms of surgical and clinical reliability and early performance outcomes. METHOD In this retrospective review we describe the complication rate (including electrode array tip fold-over), NRT thresholds, hearing preservation, power efficiency and CI performance outcomes in a continuous series of 40 cochlear implants CI532 performed between October 2016 and November 2017 in 17 adults and 13 children with severe to profound hearing loss. RESULTS Preliminary data from these groups reveals some low-frequency hearing preservation in the CI532 group although none of the patients were conventional hearing preservation candidates. NRT thresholds, power efficiency, and BKB sentences in quiet were measured at 3 and 6 months post activation. There were no significant differences in these results. The average BKB score in quiet increases from 22% pre-operatively to 58% at 3 months and 70% at 6 months. In addition, although hearing preservation was not an objective, low-frequency thresholds were preserved in 20% of cases at 3 and 6 months post-operatively. Complications were observed in 5 cases, one case with non-device related aerocoele and four related to the device array: two cases of tip roll over, one case of the electrode array being placed extra-cochlea, and one case with the electrode buckling into the middle ear. The last 2 cases were dealt with per-operatively. DISCUSSION Our preliminary results with the CI532 implant indicate that it may be reliably placed with standard surgical techniques but care is needed during the deployment of the electrode. Further initial data suggest that switch on and early electrophysiological measures are comparable to the existing CI 512 device. However whilst preliminary, our data suggest that it may be possible to use this electrode for hearing preservation. However, further studies are required to determine its definitive advantage over other electrode designs. CONCLUSION CI532 is a reliable device offering good initial results and could be an option for hearing preservation although further studies are required.
Collapse
Affiliation(s)
- Manuel Gomez Serrano
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| | - Sharmila Patel
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| | - Robert Harris
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| | - David Selvadurai
- a St George's Auditory Implant Service, St Georges NHS Foundation Trust London , London , UK
| |
Collapse
|
40
|
Berg KA, Noble JH, Dawant BM, Dwyer RT, Labadie RF, Gifford RH. Speech recognition as a function of the number of channels in perimodiolar electrode recipients. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:1556. [PMID: 31067952 PMCID: PMC6435372 DOI: 10.1121/1.5092350] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Revised: 02/04/2019] [Accepted: 02/09/2019] [Indexed: 05/28/2023]
Abstract
This study investigated the number of channels needed for maximum speech understanding and sound quality in 30 adult cochlear implant (CI) recipients with perimodiolar electrode arrays verified via imaging to be completely within scala tympani (ST). Performance was assessed using a continuous interleaved sampling (CIS) strategy with 4, 8, 10, and 16 channels and n-of-m with 16 maxima. Listeners were administered auditory tasks of speech understanding [monosyllables, sentences (quiet and +5 dB signal-to-noise ratio, SNR), vowels, consonants], spectral modulation detection, as well as subjective estimates of sound quality. Results were as follows: (1) significant performance gains were observed for speech in quiet (monosyllables and sentences) with 16- as compared to 8-channel CIS, (2) 16 channels in a 16-of-m strategy yielded significantly higher outcomes than 16-channel CIS for sentences in noise (percent correct and subjective sound quality) and spectral modulation detection, (3) 16 channels in a 16-of-m strategy yielded significantly higher outcomes as compared to 8- and 10-channel CIS for monosyllables, sentences (quiet and noise), consonants, spectral modulation detection, and subjective sound quality, (4) 16 versus 8 maxima yielded significantly higher speech recognition for monosyllables and sentences in noise using an n-of-m strategy, and (5) the degree of benefit afforded by 16 versus 8 maxima was inversely correlated with mean electrode-to-modiolus distance. These data demonstrate greater channel independence with perimodiolar electrode arrays as compared to previous studies with straight electrodes and warrant further investigation of the minimum number of maxima and number of channels needed for maximum auditory outcomes.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Jack H Noble
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Benoit M Dawant
- Department of Electrical Engineering & Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA
| | - Robert T Dwyer
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - Robert F Labadie
- Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA
| |
Collapse
|
41
|
Giardina CK, Krause ES, Koka K, Fitzpatrick DC. Impedance Measures During in vitro Cochlear Implantation Predict Array Positioning. IEEE Trans Biomed Eng 2019; 65:327-335. [PMID: 29346102 DOI: 10.1109/tbme.2017.2764881] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Improper electrode placement during cochlear implant (CI) insertion can adversely affect speech perception outcomes. However, the intraoperative methods to determine positioning are limited. Because measures of electrode impedance can be made quickly, the goal of this study was to assess the relationship between CI impedance and proximity to adjacent structures. METHODS An Advanced Bionics CI array was inserted into a clear, plastic cochlea one electrode contact at a time in a saline bath (nine trials). At each insertion depth, response to biphasic current pulses was used to calculate access resistance (Ra), polarization resistance (Rp), and polarization capacitance (Cp). These measures were correlated to actual proximity as assessed by microscopy using linear regression models. RESULTS Impedance increased with insertion depth and proximity to the inner wall. Specifically, Ra increased, Cp decreased, and Rp slightly increased. Incorporating all impedance measures afforded a prediction model (r = 0.88) while optimizing for sub-mm positioning afforded a model with 78.3% specificity. CONCLUSION Impedance in vitro greatly changes with electrode insertion depth and proximity to adjacent structures in a predicable manner. SIGNIFICANCE Assessing proximity of the CI to adjacent structures is a significant first step in qualifying the electrode-neural interface. This information should aid in CI fitting, which should help maximize hearing and speech outcomes with a CI. Additionally, knowledge of the relationship between impedance and positioning could have utility in other tissue implants in the brain, retina, or spinal cord.
Collapse
|
42
|
Mistrík P, Jolly C, Sieber D, Hochmair I. Challenging aspects of contemporary cochlear implant electrode array design. World J Otorhinolaryngol Head Neck Surg 2018; 3:192-199. [PMID: 29780962 PMCID: PMC5956130 DOI: 10.1016/j.wjorl.2017.12.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Accepted: 12/12/2017] [Indexed: 01/25/2023] Open
Abstract
Objective A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Methods Review of up-to-date literature. Results Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Conclusions Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the advantages of both types: perimodiolar location in the basal turn extended to lateral wall location for higher turn locations.
Collapse
|
43
|
Audiological Outcomes and Map Characteristics in Children With Perimodiolar and Slim Straight Array Cochlear Implants in Opposite Ears. Otol Neurotol 2017; 38:e320-e326. [DOI: 10.1097/mao.0000000000001539] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
44
|
Abstract
Cochlear implantation (CI) surgery is a very successful technique, performed on more than 300,000 people worldwide. However, since the challenge resides in obtaining an accurate surgical planning, computational models are considered to provide such accurate tools. They allow us to plan and simulate beforehand surgical procedures in order to maximally optimize surgery outcomes, and consequently provide valuable information to guide pre-operative decisions. The aim of this work is to develop and validate computational tools to completely assess the patient-specific functional outcome of the CI surgery. A complete automatic framework was developed to create and assess computationally CI models, focusing on the neural response of the auditory nerve fibers (ANF) induced by the electrical stimulation of the implant. The framework was applied to evaluate the effects of ANF degeneration and electrode intra-cochlear position on nerve activation. Results indicate that the intra-cochlear positioning of the electrode has a strong effect on the global performance of the CI. Lateral insertion provides better neural responses in case of peripheral process degeneration, and it is recommended, together with optimized intensity levels, in order to preserve the internal structures. Overall, the developed automatic framework provides an insight into the global performance of the implant in a patient-specific way. This enables to further optimize the functional performance and helps to select the best CI configuration and treatment strategy for a given patient.
Collapse
|
45
|
Encapsulated cell device approach for combined electrical stimulation and neurotrophic treatment of the deaf cochlea. Hear Res 2017; 350:110-121. [PMID: 28463804 DOI: 10.1016/j.heares.2017.04.013] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 03/15/2017] [Accepted: 04/23/2017] [Indexed: 12/21/2022]
Abstract
Profound hearing impairment can be overcome by electrical stimulation (ES) of spiral ganglion neurons (SGNs) via a cochlear implant (CI). Thus, SGN survival is critical for CI efficacy. Application of glial cell line-derived neurotrophic factor (GDNF) has been shown to reduce SGN degeneration following deafness. We tested a novel method for local, continuous GDNF-delivery in combination with ES via a CI. The encapsulated cell (EC) device contained a human ARPE-19 cell-line, genetically engineered for secretion of GDNF. In vitro, GDNF delivery was stable during ES delivered via a CI. In the chronic in vivo part, cats were systemically deafened and unilaterally implanted into the scala tympani with a CI and an EC device, which they wore for six months. The implantation of control devices (same cell-line not producing GDNF) had no negative effect on SGN survival. GDNF application without ES led to an unexpected reduction in SGN survival, however, the combination of GDNF with initial, short-term ES resulted in a significant protection of SGNs. A tight fibrous tissue formation in the scala tympani of the GDNF-only group is thought to be responsible for the increased SGN degeneration, due to mechanisms related to an aggravated foreign body response. Furthermore, the fibrotic encapsulation of the EC device led to cell death or cessation of GDNF release within the EC device during the six months in vivo. In both in vitro and in vivo, fibrosis was reduced by CI stimulation, enabling the neuroprotective effect of the combined treatment. Thus, fibrous tissue growth limits treatment possibilities with an EC device. For a stable and successful long-term neurotrophic treatment of the SGN via EC devices in human CI users, it would be necessary to make changes in the treatment approach (provision of anti-inflammatories), the EC device surface (reduced cell adhesion) and the ES (initiation prior to fibrosis formation).
Collapse
|
46
|
Mittmann P, Todt I, Ernst A, Rademacher G, Mutze S, Göricke S, Schlamann M, Lang S, Arweiler-Harbeck D, Christov F. Radiological and NRT-Ratio-Based Estimation of Slim Straight Cochlear Implant Electrode Positions: A Multicenter Study. Ann Otol Rhinol Laryngol 2016; 126:73-78. [PMID: 27780910 DOI: 10.1177/0003489416675355] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVES An intraoperative neural response telemetry-ratio (NRT-ratio) was established, which can provide information about the intraoperative intracochlear electrode array position for perimodiolar electrodes. METHODS In a retrospective controlled study in 2 tertiary referral centers, the electrophysiological data sets of 50 patients with measured intraoperative auto-NRTs and postoperative radiological examinations were evaluated. All patients were implanted with Nucleus slim straight electrodes. The NRT-ratio was calculated by dividing the average auto-NRT data from electrodes 16 to 18 with the average from electrodes 5 to 7. Using a flat panel tomography system or a computed tomography, the position of the electrode array was certified radiological. RESULTS Radiologically, 2 out of 50 patients were identified with an electrode translocated from the scala tympani into the scala vestibuli. The radiologically estimated electrodes indicating a scalar change showed a regular NRT-ratio but nonspecific NRT-level changes at the localization of translocation.
Collapse
Affiliation(s)
| | - Ingo Todt
- Department of Otolaryngology, ukb Berlin, Germany
| | | | | | | | - Sophia Göricke
- Department of Neuroradiology and Radiology, University Hospital of Essen, University Duisburg-Essen, Essen, Nordrhein-Westfalen, Germany
| | - Marc Schlamann
- Department of Neuroradiology and Radiology, University Hospital Giessen and Marburg GmbH, Germany
| | - Stephan Lang
- Department of Otolaryngology, Head and Neck Surgery, University Hospital of Essen, University Duisburg-Essen, Germany
| | - Diana Arweiler-Harbeck
- Department of Otolaryngology, Head and Neck Surgery, University Hospital of Essen, University Duisburg-Essen, Germany
| | - Florian Christov
- Department of Otolaryngology, Head and Neck Surgery, University Hospital of Essen, University Duisburg-Essen, Germany
| |
Collapse
|
47
|
Stimulation parameters differ between current anti-modiolar and peri-modiolar electrode arrays implanted within the same child. The Journal of Laryngology & Otology 2016; 130:1007-1021. [PMID: 27739380 DOI: 10.1017/s0022215116009026] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To compare stimulation parameters of peri-modiolar and anti-modiolar electrode arrays using two surgical approaches. METHODS Impedance, stimulation thresholds, comfortably loud current levels, electrically evoked compound action potential thresholds and electrically evoked stapedial reflex thresholds were compared between 2 arrays implanted in the same child at 5 time points: surgery, activation/day 1, week 1, and months 1 and 3. The peri-modiolar array was implanted via cochleostomy in all children (n = 64), while the anti-modiolar array was inserted via a cochleostomy in 43 children and via the round window in 21 children. RESULTS The anti-modiolar array had significantly lower impedance, but required higher current levels to elicit thresholds, comfort, electrically evoked compound action potential thresholds and electrically evoked stapedial reflex thresholds than the peri-modiolar array across all time points, particularly in basal electrodes (p < 0.05). The prevalence of open electrodes was similar in anti-modiolar (n = 5) and peri-modiolar (n = 3) arrays. CONCLUSION Significant but clinically acceptable differences in stimulation parameters between peri-modiolar and anti-modiolar arrays persisted four months after surgery in children using bilateral cochlear implants. The surgical approach used to insert the anti-modiolar array had no overall effect on outcomes.
Collapse
|
48
|
Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study. Eur Arch Otorhinolaryngol 2016; 273:4251-4256. [DOI: 10.1007/s00405-016-4175-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Accepted: 06/24/2016] [Indexed: 10/21/2022]
|